TPDRO 1100 Advanced Catalyst Characterization. For Temperature Programmed Desorption, Reduction, Oxidation and Chemisorption

Similar documents
Thermo Scientific TPDRO 1100 Advanced Catalyst Characterization

Finnigan TC/EA. High Temperature Conversion Elemental Analyzer

Thermo Scientific FLASH HT Plus Elemental Analyzer for IRMS

MetWorks Metabolite Identification Software

Short-Info. TPD/TPR/TPO-Measurements. Measurement Principle. Pre-treatment 1/2

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

Thermo Scientific ELEMENT GD Glow Discharge Mass Spectrometer

for XPS surface analysis

AutoChem II 2920 The Cayalyst Characterization Laboratory

AutoChem II 2920 A Catalyst Characterization Laboratory

Hiden CATLAB Systems Microreactor for Catalysis Studies & Thermal Analysis

High-Pressure Volumetric Analyzer

Thermo Scientific LTQ Velos Dual-Pressure Linear Ion Trap

SOPHISTICATED DESIGN, INTUITIVE OPERATION, RESEARCH-GRADE RESULTS

Fast, Effective XPS Point Analysis of Metal Components

of mass spectrometry

Catalyst Characterization Using Thermal Conductivity Detector *

Chemisorption Analyzer. ChemStar TPx. Catalysts. Ceramics. Energy. Carbons. Zeolites. Polymers Quantachrome Corporation Rev.

The Raman Spectroscopy of Graphene and the Determination of Layer Thickness

Characterization of Polymers and Plastics (pellets, powders and films) by the Thermo Scientific FLASH 2000 Elemental Analyzer

Catalysis CAPABILITIES

Introduction to Fourier Transform Infrared Spectroscopy

ECS8020 ORGANIC ELEMENTAL ANALYZER CHNS-O Analyzer

Thermo Scientific LC IsoLink

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling

A Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry

Thermo Scientific K-Alpha + XPS Spectrometer. Fast, powerful and accessible chemical analysis for surface and thin film characterization

costech instruments ECS 4010 Elemental Combustion System CHNS-O

TPR, TPO and TPD Examination of Cu 0.15 Ce 0.85 O 2-y Mixed Oxide Catalyst Prepared by Co-precipitation Synthesis

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

AutoChem II The Catalyst Characterization Laboratory

A Strategy for an Unknown Screening Approach on Environmental Samples Using HRAM Mass Spectrometry

Introduction to Fourier Transform Infrared Spectroscopy

Insights Into the Nanoworld Analysis of Nanoparticles with ICP-MS

Thermo Scientific TRITON Thermal Ionization MS. Thermo Scientific NEPTUNE Multicollector ICP-MS. High Resolution Multicollector Mass Spectrometers

Nitrogen/Protein determination of infant food by the Thermo Scientific FlashSmart Elemental Analyzer using helium or argon as carrier gases

Fitting of ETD Rate Constants for Doubly and Triply Charged Ions in a Linear Ion Trap

NON-METHANE ORGANIC CARBON ANALYZER (NMOC Method 25)

LTQ XL Linear Ion Trap Mass Spectrometer More Structural Information with MS n

Finnigan TRACE DSQ GC/MS

Finnigan TRITON Finnigan NEPTUNE. High Resolution Multicollector Mass Spectrometers

Thermo Scientific GasBench II

Improved Throughput and Reproducibility for Targeted Protein Quantification Using a New High-Performance Triple Quadrupole Mass Spectrometer

A Study of Stability, Robustness and Time Efficiency of a New HPLC and a New Tandem MS

Thermo Scientific ELEMENT GD PLUS Glow Discharge Mass Spectrometer. Defining quality standards for the analysis of solid samples

Complete Materials Deformulation Using TGA-IR

Atmospheric Analysis Gases. Sampling and analysis of gaseous compounds

Finnigan TSQ Quantum Discovery MAX

ChemStar. ChemStar TPx. TPx. Catalysts. Ceramics. Energy. Carbons. Zeolites. Polymers. chemisorption analyzer

Hiden Isochema. Gravimetric Gas & Vapor Sorption Analyzers. Hiden Isochema IGA Series. Advancing Sorption Analysis

Key Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery

Rapid Quan/Qual Metabolic Stability Analysis with Online Oxidative Metabolism Synthesis

Petrochemical. Transformer Oil Gas Analysis - TOGA

High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems

Thermo Scientific irm-gc/ms Technology

LCQ Fleet Ion Trap LC/MS n Exceptional Analytical Value

ARL OPTIM X X-Ray Fluorescence Spectrometer. Optimized Performance for Your Application

ARGUS VI. Static Vacuum Mass Spectrometer. Static Vacuum ARGUS VI. Multicollection Low Volume Precision

C80. Calvet Calorimeter From ambient to 300 C. A trademark of KEP Technologies group

Automated multi-vapor gravimetric sorption analyzer for advanced research applications

Thermo Scientific DELTA V Advantage DELTA V Plus

DFS Magnetic Sector GC/MS

HIGH-RESOLUTION, IMPROVED THROUGHPUT MICROPORE ANALYSES 3Flex Surface and Catalyst Characterization

Thermo Fisher Scientific, San Jose, CA; 2 Kelleher Lab, Northwestern University, Evanston, IL; 3

Evaluation of a New HPLC, a New Tandem MS and a New Data Processing Software for General Clinical Use

Rapid Catalyst Screening Reactors

Gas Chromatography. Presented By Mr. Venkateswarlu Mpharm KTPC

Automated, intelligent sample preparation: Integration of the ESI prepfast Auto-dilution System with the Thermo Scientific icap 7400 ICP-OES

New Multi-Collector Mass Spectrometry Data for Noble Gases Analysis

XPS Surface Characterization of Disposable Laboratory Gloves and the Transfer of Glove Components to Other Surfaces

Elemental Analysis: NCS characterization of paper

By Rogéria Amaral and Sébastien Thomas

HELIX SFT. Static Vacuum ARGUS VI HELIX SFT. Static Vacuum Mass Spectrometer Static Vacuum Mass Spectrometer

Chromatography. Gas Chromatography

IN QUALITATIVE ANALYSIS,

Method Development for a Simple and Reliable Determination of PCBs in Mineral Insulating Oil by SPME-GC-ECD

HR/AM Targeted Peptide Quantification on a Q Exactive MS: A Unique Combination of High Selectivity, High Sensitivity, and High Throughput

Supporting Information High Activity and Selectivity of Ag/SiO 2 Catalyst for Hydrogenation of Dimethyloxalate

Thermo Scientific ITQ Series Quadrupole Ion Trap GC/MS n

Methods of pollution control and waste management - laboratory. Adsorptive removal of volatile organic compounds from gases streams

Optimizing GC Parameters for Faster Separations with Conventional Instrumentation

AOAC Official Method 2016.xx. Determination of Total Sulfur in Fertilizers by High Temperature Combustion

Accurate and Precise Sulfur Analysis using the Thermo Scientific FlashSmart Elemental Analyzer

Sintering-resistant Ni-based Reforming Catalysts via. the Nanoconfinement Effect

Automating Method Development with an HPLC System Optimized for Scouting of Columns and Eluents

THE APPLICATION OF PROCESS MASS SPECTROMETRY TO FUMED SILICA PRODUCTION

Plasma-free Metanephrines Quantitation with Automated Online Sample Preparation and a Liquid Chromatography-Tandem Mass Spectrometry Method

Thermo Scientific Pesticide Explorer Collection. Start-to-finish. workflows for pesticide analysis

AN2970 Application note

Highly Efficient and Robust Au/MgCuCr 2 O 4 Catalyst for Gas-Phase Oxidation of Ethanol to Acetaldehyde

DYNAMIC SORPTION. Dynamic Sorption Breakthrough Analyzer. Gas Purification

DYNAMIC SORPTION. Dynamic Sorption Breakthrough Analyzer. Gas Purification. Ceramics. Energy. Carbons. Pharma

High Pressure DSC Differential Scanning Calorimeter

The Elzone II Particle Count and Size Analyzer

Be prepared to discuss the quantitative comparison method in the oral exam.

Semiconductor Capabilities. Lab-to-Fab Solutions

Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil

Developing Carbon Tolerance Catalyst for Dry Methane Reforming

A Tunable Process: Catalytic Transformation of Renewable Furfural with. Aliphatic Alcohols in the Presence of Molecular Oxygen. Supporting Information

Transcription:

s u r f a c e a n a l y s i s TPDRO 11 Advanced Catalyst Characterization For Temperature Programmed Desorption, Reduction, Oxidation and Chemisorption Analyze Detect Measure Control

TPDRO 11 Advanced Catalyst Characterization For Temperature Programmed Desorption, Reduction, Oxidation and Chemisorption TPDRO 11: A technological breakthrough for advanced The development of catalysts has contributed enormously to change our everyday life. Catalysts are ubiquitously used in modern industrial processes such as in petrochemical plants, pharmaceutical, fine chemistry, food industry, etc. Catalysts are typically composed by an active phase (usually a noble metal or an acid/base site) that is deposited and dispersed on a porous support (i.e. alumina, silica, etc.). The active phase in a solid catalyst has high affinity for the molecules of given reactants. The molecules are first chemisorbed onto the active surface before reacting between themselves. The catalysts activity, for a given reaction, is usually proportional to the number of surface active sites. As for metal supported catalysts, the active sites are constituted by the exposed metallic surface. There are several well known analytical techniques permitting to evaluate parameters such as metal specific surface area, the metal dispersion and the average metal aggregate size. One of the fastest and reliable technique is the pulse chemisorption in flow. Additional studies related to catalysts, provide the determination of the energies involved in the chemisorption and desorption processes of the reactants and products. The above parameters can be obtained in a automated way by means of the TPDRO 11 using the available techniques of thermal programmed desorption (TPD), reduction (TPR), oxidation (TPO) and pulse chemisorption. Catalysts characterization now made easier and faster with the innovative TPDRO 11 The complete characterization sequence of an active solid generally consists of two separate phases: the pre-treatment and the analysis. Depending on the type of analysis required, the sample needs to be activated before the test. For instance, when performing temperature programmed desorption, the surface of the catalyst must first be rid of pre-adsorbed gas species on its surface and then saturated with a suitable reactive gas. The pre-treatment procedure is usually a very time consuming and a delicate process as all the analytical results are pre-treatment sensitive. A sequence of different gases flows through the catalyst bed at different temperatures. Heating rates must be performed with high precision to ensure reliable results. The TPDRO 11 features a fully automatic pre-treatment sequence with an unlimited selection of procedures. The settings of the activation procedures are memorized in the dedicated software database, which can be readily recalled and applied on similar samples therefore simplifying the setup process. The development of catalysts has contributed enormously to change our everyday life.

catalyst characterization Catalyst activation and analysis: "parallel" is faster than "serial"! Sometimes the pre-treatment procedure might lasts for hours, whereas the analyses are relatively short. Once the catalyst is activated for the analysis, it must not be exposed to any other reactive gases such as oxygen in the air, but should be kept under an inert gas. An innovative and proprietary reactor designed by Thermo Electron, circumvent the problem of sample exposure to atmospheric gases after the sample pretreatment step. The reactor can be closed and isolated from the environment after catalyst activation and the catalyst can be kept under an inert gas for subsequent operations. The user is able to transport the complete reactor along with the isolated and pretreated catalyst avoiding any risk of sample contamination prior to the analysis. This important feature generates a number of additional possibilities: Simultaneous pre-treatment and analysis on two different catalysts The catalyst activation can be performed in the TPDRO 11 pre-treatment port or in another system (i.e. in a fume hood, inside a controlled environment, etc.) 84863 6 12 5 75443 The TPDRO 11 can simultaneously and independently perform the activation on a sample in the pre-treatment port and the analysis on another sample in the analysis port, saving valuable lab time and practically doubling the productivity 1 4 3 6 2 4 1 2 5 1 15 2 Time ( min ) Unlimited automatic sequence of multiple preparation /analysis parallel is faster than serial! Temperature ( C ) In addition to the above operations, TPDRO permits to work sequentially, that means without to touch the reactor when moving from the pre-treatment to the analytical stage. The instrument will automatically perform the pre-treatment sequence of catalyst activation followed by the experiment, without any operator s intervention. Signal (mv) 8

Key features of the TPDRO 11 Precise gas control for high sensitivity detection Precise gas injection systems for pulse chemisorption Two independent ovens improve productivity Temperature control both during the increase and decrease phases of the catalyst investigation Real sample temperature monitored continuously Additional analytical possibilities External thermoregulation bath Vapour generator optional kit Additional detectors for more comprehensive investigation of surface reactions In the TPDRO the flow is regulated by a mass flow controller in a single gas line passing first to the TCD reference channel and then to the reactor and finally again to the TCD analytical channel. This configuration ensures that the flow is identical in both the TCD filaments, thus giving the ultimate in baseline stability and high sensitivity detection therefore more reliable results. Very low metal percentage catalysts can be tested easily, minimizing the sample load in the reactor and thus avoiding problems like re-adsorption and channelling effects. For calibration and pulse chemisorption, the probe gas can be injected into the reactor manually using a gas tight syringe or automatically through a high precision loop valve system. The loop selection can be as small as.15 cc and without "shutter" dead volume which is generating noise peaks in the baseline. Pulse gas can also be made of a low percentage mixture of a reactive gas in a suitable inert gas, thus permitting extremely small gas injections to test very low metal percentage catalysts. TPDRO features two separate and independent ovens. Both can be used independently for the sample activation (pre-treatment port) or the experiment (analysis port) up to 11 C. The ovens are antimagnetic to avoid additional baseline noise when the carrier is polar. There is also a special fast cooling connection to compressed air to facilitate the cooling of the oven. Oven temperature is raised linearly in a wide range of values. Rates of up to 4 C/min is possible up to 75 C or 2 C/min up to 11 C extending the analytical performance especially in TPD experiments. In addition, a specially designed system permits to control the temperature rate also when decreasing the temperature. This allows detecting possible chemical reactions even during the sample cooling process. A thermocouple is inserted into the special reactor directly over the sample or inside the catalyst bed. The probe is very thin, thus featuring a very fast response time to temperature variations. In addition, the sensor itself is protected by a quartz shield that avoids contact between the thermocouple and the reactive gases. Single point BET in flow analysis permits the "in-situ" evaluation of the total surface of the catalyst before and after the experiment, thus revealing immediately if morphological changes occurred to the sample during the course of the analysis. The reactor can be fitted to a special recirculation bath for temperature control in the range of room temperature or even below zero degrees Celsius. The temperature can be precisely regulated by means of an external liquid circulation system during pulse chemisorption experiments. A number of organic vapours can be generated at constant temperature and injected quantitatively into the reactor, thus saturating the catalyst. The vapour can then be desorbed by TPD experiment. In sequence to the TCD detector, a suitable mass spectrometer can be connected to the TPDRO. The advantage is that the MS provides information of the gaseous species evolving from the catalyst, permitting, both a qualitative and quantitative determination Special design reactor with built-in by-pass valve A special reactor has been designed to insulate the catalyst from the enviroment after the activation. The unique reactor permits to prepare and measure simultaneously two catalysts, saving valuable lab time. In addition it is possible to prepare the catalyst in external preparation devices, especially when using dangerous or very corrosive gases for utmost safety of the operator. When the sample is ready, the sealed reactor can be transferred safely to the TPDRO for testing.

5 4 3 2 1 1 2 3 8 6 4 2 Analytical techniques available on TPDRO 11 Temperature programmed reduction and oxidation The objectives of this technique are essentially the following: To find the most efficient reduction/ oxidation conditions To identify the supported precursor phases and their interactions with the support To characterize complex systems, as bimetallic or doped catalyst, to determine the role of the second component and to establish alloy formation or promotion effects TPO example with temperature decrease control Temperature programmed desorption In the TPD studies the solid system is previously activated and then saturated with a probe reactive gas in isothermal conditions. During the temperature programmed desorption analysis, the sample is submitted to an increasing temperature at constant rate and it is swept by an inert gas such as helium, argon or nitrogen. The sample surface desorbs the gas that has been previously chemisorbed and the thermal conductivity detector monitors the process. The information produced by TPD experiments are related to: Energetic abundance of active sites Activation energy for desorption Free metal surface area Example of hydrogen TPD Pulse chemisorption in flow The chemisorption analysis in a flow system is denoted Pulse Chemisorption. The gas to be chemisorbed is introduced as a pulse, via a calibrated loop valve, into the stream of the inert carrier gas flowing through the reactor and the sample. The catalyst is previously activated by an appropriate pretreatment procedure and then submitted to chemisorption. The result is demonstrated like a series of peaks with increasing peak height. The software then automatically calculates the exposed metal area and metal dispersion. 1539356 TPR example on Co catalyst In the TPR technique an oxidized catalyst is submitted to a programmed temperature increase, while a reducing gas mixture is passed over it (usually, hydrogen diluted in some inert gas as nitrogen or argon). In the TPO technique, the catalyst is in the reduced form and it is submitted to a programmed temperature increase, but in this case, an oxidizing mixture of gas (typically oxygen in helium) is passed over the sample. Signal (mv/g) 16885 1494327 Ammonia TPD spectra at different temperature rates 1627429 Time ( min ) Temperature ( C ) Hydrogen 5% pulses on Pt catalyst

TPDRO for Total chemisorbed / desorbed gas specific volume Metal specific surface area Metal dispersion percentage Peaks automatic or manual integration, integration limits, maximum peak temperature, etc. Calculation of metal percentage from TPR experiments Calculation of desorption activation energy from TPD Calculation of mass / metal percentage correction in multiple experiments TPR/TPO temperature/time profiles Graphs TCD signal (mv or mv/g), oven and sample temperatures versus time TCD signal (mv or mv/g ) versus oven or sample temperature Plot of activation energy for desorption Overlay of multiple experiments on a single graph with multiple calculations Special design software The software of TPDRO has been specifically designed to run the sample preparation and analyses automatically store data in real time, generate graphs, reports and calculations. All the operations required for processing the data are contained in the TPDRO software suite, like baseline subtraction, automatic peaks integration routine, tabular results, overlay of different experiments as well as printout of results. Reports can also be generated directly in the rtf format. The software is integrated with a number of databases containing all the essential information related to gases and gas-vapour mixtures, reactions, samples, metals, reaction stoichiometry, preparation and analytical methods. In addition to these offices,thermo Electron Corporation maintains a network of representative organizations throughout the world. Australia +61 2 8844 95 analyze.au@thermo.com Austria +43 1 333 534 analyze.at@thermo.com Belgium +32 2 482 3 3 analyze.be@thermo.com Canada +1 8 532 4752 analyze.ca@thermo.com China +86 1 585 3588 analyze.cn@thermo.com France +33 1 6 92 48 analyze.fr@thermo.com Germany +49 613 48 analyze.de@thermo.com India +91 22 2778 111 analyze.in@thermo.com Italy +39 2 95 591 analyze.it@thermo.com Japan +81 45 453 91 analyze.jp@thermo.com Netherlands +31 76 587 98 88 analyze.nl@thermo.com Scandinavia +46 8 556 468 analyze.se@thermo.com South Africa +27 11 57 184 analyze.sa@thermo.com Spain +34 91 657 493 analyze.es@thermo.com Switzerland +41 61 48784 analyze.ch@thermo.com UK +44 1442 233555 analyze.uk@thermo.com USA +1 8 532 4752 analyze.us@thermo.com www.thermo.com Desorption Energy Calculation from ammonia TPD DESORPTION ENERGY CALCULATION Sample: 32.63 File Pk Rate ( C/min) Peak T( C) 1/T(K) Ln(T_/Rate) TpdNH3_2C.11 1 2 173.224 9.2 TpdNH3_15C.11 1 15 153.234 9.4 TpdNH3_1C.11 1 1 131.247 9.7 TpdNH3_5C.11 1 5 98.269 1.22 Thermo Electron Limited, Milan, Italy is ISO Certified. Gas constant (J/mol K): 8.314451 Correlation Factor:.9989 Slope: 227.2316 Intercept: 4.927 Energy of des.(kj/mol): 18.8757 Arrhenius prefactor: 37.898 25 Thermo Electron Corporation. All rights reserved. All trademarks are the property of Thermo Electron Corporation and its subsidiaries. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. BR112_E 3/5C