PROCESS AND ENVIRONMENTAL APPLICATIONS OF GAS CHROMATOGRAPHY WITH THE REDUCTION GAS DETECTOR

Similar documents
AUTOMATED ONLINE IDENTIFICATION AND MONITORING OF IMPURITIES IN GASES

Application Note S/SL

NON-METHANE ORGANIC CARBON ANALYZER (NMOC Method 25)

2B Technologies, Inc. An InDevR Company

Fast Determination of Impurities in Propane- Propylene Streams Using a Pulsed Flame Photometric Detector (PFPD) and a New Capillary.

Far UV Absorbance Detector

Gas Chromatography (GC)! Environmental Organic Chemistry CEE-PUBH Analysis Topic 5

The Analysis of Trace Contaminants in High Purity Ethylene and Propylene Using GC/MS. Application. Agilent Technologies/Wasson ECE Monomer Analyzer

Chemistry Instrumental Analysis Lecture 27. Chem 4631

Monomer Analysis. Analysis by Gas Chromatography WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 23: GAS CHROMATOGRAPHY

Petrochemical. Transformer Oil Gas Analysis - TOGA

Analyze Hydrocarbon Impurities in 1,3-Butadiene with an Agilent J&W GS-Alumina PT Column

2401 Gas (liquid) Chromatography

Gas Chromatography. Presented By Mr. Venkateswarlu Mpharm KTPC

High-Speed Gas and Headspace Analysis for the Process-Line and Laboratory: SIFT- MS IFPAC 2017

THE NEW QUANTITATIVE ANALYTICAL METHOD FOR ULTRATRACE SULFUR COMPOUNDS IN NATURAL GAS

Gas Chromatography. Rosa Yu, David Reckhow CEE772 Instrumental Methods in Environmental Analysis CEE 772 #16 2

Gas Chromatography. Introduction

APPLICATION NOTE. A Capillary Approach to ASTM D3606: Test Method for Determination of Benzene and Toluene in Finished Motor and Aviation Gasoline

UV Hound Series. Dependable High Quality Air Monitoring. Accurate Readings Within Seconds. Portable UVDOAS Multi-gas Analyzers. Multi-Gas Capability

CH 2252 Instrumental Methods of Analysis Unit V Gas Chromatography. M. Subramanian

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

GC Instruments. GC Instruments - Sample Introduction

RS DYNAMICS ECOPROBE 5. Portable IR/PID Gas Analyzer PID. PID and IR Analyzers

Analytical techniques: Environmental samples. Lecture 2 Universidade do Algarve

GAS CHROMATOGRAPHY (GC)

Atmospheric Analysis Gases. Sampling and analysis of gaseous compounds

Introduction to Gas Chromatography

The Claviature of Gas Analysis

Chapter 31 Gas Chromatography. Carrier Gas System

PRINCIPLES AND APPLICATION OF CHROMATOGRAPHY. Dr. P. Jayachandra Reddy Mpharm PhD Principal & professor KTPC

Sub-ppt Atmospheric Measurements Using PTV-GC-FID and Real-Time Digital Signal Processing

CHAPTER 6 GAS CHROMATOGRAPHY

Experiment 6 Simple and Fractional Distillation

Chapter 27: Gas Chromatography

Gas Chromatography (Chapter 2 and 3 in The essence of chromatography)

Gas Chromatography (GC)

Virtually Particle-Free Rt -Silica BOND Columns

2Fe 2 O 3 +3H 2 S FeS+FeS x +S+3H 2 O


Gas chromatography. Advantages of GC. Disadvantages of GC

Analysis of TO-15/TO-17 air toxics in urban air using TD GC/TOF MS and automated compound identification software

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS

STANDARD OPERATING PROCEDURES

1.0 Reactive Gas Chromatography Design and Setup Procedure for Catalyst Pelletization & Inlet Packing Software and Method.

Introduction. David B. Wurm, Kefu Sun, and William L. Winniford. Abstract

Product Brief. - Hydrocarbons alkanes, alkenes, alkynes, dienes including natural gas, refinery gas, liquified petroleum gas

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY

TOUR OF SOIL CHEMISTRY LABS (09/22/07)

Cantilever enhanced tunable diode laser photoacoustic spectroscopy in gas purity measurement case study: acetylene in ethylene

Chemical Analysis. Low Level Oxygenates Analyzer. Trace Analysis of Oxygenates in Hydrocarbon Matrices. Gas Chromatography.

Luminescence transitions. Fluorescence spectroscopy

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

Muliple Gas#3 plus Sulfur GC Configuration

Permanent Gas Analysis by Gas Chromatography Vacuum Ultraviolet Spectroscopy

Measurement Technique and its Application to Trace Components of Atmospheric Gas

Gas Chromatography in the Low Concentration Determination of Nitrous Oxide and Volatile Anaesthetics

THE APPLICATION OF PROCESS MASS SPECTROMETRY TO FUMED SILICA PRODUCTION

Principles of Gas- Chromatography (GC)

Chromatography. Gas Chromatography

METHOD 8033 ACETONITRILE BY GAS CHROMATOGRAPHY WITH NITROGEN-PHOSPHORUS DETECTION

Multidimensional GC. Multidimensional GC. Multidimensional GC. Why bother? Examples of complex samples. Multidimensional Gas Chromatography

Prima PRO Process Mass Spectrometer

Gas Chromatography CHEM Dr. Reem M. Alghanmi st term

Chromatographic Methods of Analysis Section: 5 Gas Chromatography (GC) Prof. Tarek A. Fayed

Polymer plants continue to seek ways to increase production and efficiency without compromising safety.

Understanding Gas Chromatography

VUV ANALYTICS VGA-100 GC DETECTOR Gas Chromatograph Agilent 6890 equipped with a 7683 model autosampler Restek 30m x 0.25mm x 0.

Residual Solvents in Pharmaceuticals by USP Chapter <467> Methodology

costech instruments ECS 4010 Elemental Combustion System CHNS-O

Fast Analysis of Aromatic Solvent with 0.18 mm ID GC column. Application. Authors. Introduction. Abstract. Gas Chromatography

Chapter 11 Conventional Gas Chromatography

Earth s Atmosphere. Composition

10/8/2013. Alternatives to Mass Spectrometry and Some Real-time Monitoring Measurements. Project Driven Tasks -- Process Gas Measurements

ATOC 3500/CHEM 3151 Air Pollution Chemistry Lecture 1

Real Time On-Site Odor and VOC Emission Measurements Using a znose

Introduction to Capillary GC

Analysis for Natural Gas and Similar Gaseous Mixtures by Gas Chromatography

Trace analysis of mesityl oxide and diacetone alcohol in pharmaceuticals by capillary gas chromatography with flame ionization detection

ANALYTICAL METHOD DETERMINATION OF VOLATILE ALDEHYDES IN AMBIENT AIR Page 1 of 11 Air sampling and analysis

Highly Sensitive and Rugged GC/MS/MS Tool

Introduction to IH Analytical Chemistry

UV3000. Accurate, precise, and portable ambient gas point analyzer

VALLIAMMAI ENGINEERING COLLEGE SRM Nagar, Kattankulathur

Odor Detection and Analysis using GC/SAW znose

Introduction. Chapter 1. Learning Objectives

White Paper. Overview: NDIR Definition:

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

CHAPTER 1. MEASURES OF ATMOSPHERIC COMPOSITION

The end of. mass-speculation. MS Certified Vials Pre-cleaned and certified vials for mass spectrometry

UltiMetal Plus Advanced Chemistry for Stainless Steel Surface Deactivation

A STUDY OF VOLATILE ORGANIC CARBON POLLUTION ON A UNIVERSITY CAMPUS DUE TO TRAFFIC

THEORETICAL DETERMINATION OF THE SAMPLING RATES OF DIFFUSION SAMPLERS FOR VOCS AND ALDEHYDES

SERVOTOUGH SpectraScan

Determination of Total Volatile Organic Compounds in Indoor Air Using Agilent 7667A mini TD and 7820A GC

GAS CHROMATOGRAPHY. Mobile phase is a gas! Stationary phase could be anything but a gas

STANDARD OPERATING PROCEDURES

Method for the determination of 1,3-butadiene

Transcription:

JPACSM 18 PROCESS AND ENVIRONMENTAL APPLICATIONS OF GAS CHROMATOGRAPHY WITH THE REDUCTION GAS DETECTOR Marco Succi SAES Getters S.p.A., Milano, Italy James G. Moncur Independent Consultant KEYWORDS: REDUCTION GAS DETECTOR, PPB, PPT, TRACE GAS ANALYSIS, H 2, CO, HYDRO- CARBONS, ETHYLENE OXIDE, ETHYLENE, PROPYLENE, ARSINE, PHOSPHINE, CARBONYL SULFIDE ABSTRACT The Reduction Gas Detector (RGD) is routinely used for gas chromatographic analysis of volatile compounds that are readily oxidized. The RGD has a tiny amount of HgO in a heated assembly that reacts with volatile compounds as they pass over this bed of material. This causes traces of Hg to be released into a low volume flow cell with photometer for quantitative determination of the analyte. The traces of Hg are then scrubbed with activated charcoal. The HgO bed lasts for six months to two years and is easily changed. Impurities in nitrogen, oxygen, argon, helium, ambient air, carbon dioxide, and ammonia are readily analyzed by GC as the RGD does not react with these relatively stable gases. Hydrogen, carbon monoxide, arsine, phosphine, carbonyl sulfide are measured in ethylene and propylene for catalyst protection purposes. Ethylene, ethylene oxide, arsine, phosphine, nitric oxide, ketones, aldehydes, isoprene, 1,3-butadiene, and benzene are analyzed in ambient air for industrial hygiene and environmental reasons. This paper discusses examples of GC/RGD analyses of ambient air and in chemical process monitoring and the comparison between the flame ionization detector (FID) and the RGD for organic compounds detection. INTRODUCTION The Reduction Gas Detector (RGD) is a unique, ultrasensitive detector developed for the analysis of trace hydrogen, carbon monoxide and reducing species. In the last ten years it has been widely used in several applications where its specificity, reliability, and sensitivity has been a major advantage over more traditional detectors, such as thermal conductivity detectors (TCD) or discharge ionization detectors (DID). This paper discusses some of the various ambient air and process monitoring 1-7 applications of the Reduction Gas Detector for gas chromatography. The difference between the RGD and the flame ionization detection (FID) of organic compounds is also discussed. OPERATING PRINCIPLE OF THE RGD The basic operating principle of the detector is based upon the strong absorption of UV light by mercury vapor. Compounds eluting from the column pass through a mercuric oxide bed that is heated. Reducing components, i.e. compounds that can combine with oxygen, react with the mercuric oxide and release mercury vapor. The free vapor evolved in the reaction is then detected by measuring the absorption of UV light in a photometric cell. The absorption is directly proportional to the concentration of the mercury vapor which is proportional to the concentration of the reducing analyte from the column. The following general reaction takes place: X + HgO (solid) XO + Hg (vapor) For H 2 and CO the reactions are: H 2 + HgO H 2 O + Hg CO + HgO CO 2 + Hg This technique of sensing mercury vapor lends itself to part-per-trillion (ppt) and part-per-billion (ppb) detection limits of reducing compounds. Since the detector reacts only to reducing compounds, there is no interference from the matrix such as O 2, Air, He, N 2, Ar, CO 2, etc. The actual detection limits are related to the reaction efficiency of different compounds in the mercury oxide bed as well as the sample volume injected into the column, the path length of the photometer cell, and the signal to noise level achieved through the system.

JPACSM 19 A cross sectional drawing of the detector is shown in Figure 1. The UV source is a mercury lamp with an optical filter and a reference photo diode detector to monitor lamp intensity fluctuations at 254 nm. Figure 1. Reduction Gas Detector schematic. The rest of the light travels via the light guide through the cell and out the other light guide through the 254 nm optical filter to the signal photo diode detector. The column effluent enters the HgO reaction bed which is heated to about 265 C, where the reducing compounds react and release mercury vapor. The light intensity will be different between the two photo diodes, depending upon the amount of mercury vapor in the cell. Signal processing electronics measure the difference between the two photodiodes, automatically canceling lamp flicker noise, and displaying the mercury vapor concentration. This is directly proportional to the concentration of a reducing compound eluting from the column system. The low level of mercury vapor in the carrier gas flowing from the photo cell is trapped with a scrubber before entering the ambient atmosphere. For the ultimate detection limit, it is important to have a carrier gas with a reliable negligible concentration of reducing species to optimize the detector signal to noise ratio. ENVIRONMENTAL APPLICATIONS H 2 and CO Analysis in the Atmosphere The RGD is ideally suited for the determination of ppb to part-per-million (ppm) levels of H 2 and CO in atmospheric studies. CO is involved in ozone depletion, even at very low concentrations. The RGD was mounted in an aircraft and was used by Dr. Paul Crutznen for his analyses of CO in the upper stratosphere. In these analyses, the Reduction Gas Detector is used to provide rapid and reproducible quantitative measurements 8,9. This system was designed for trace levels of H 2 and CO in the atmosphere, where there is a possibility of other high molecular weight pollutants that could interfere with the determination. Air carrier gas is preferred because it gives a minimum of upset in the baseline from the injection, is inexpensive, and readily available. A 10-port valve is used to inject the sample from the sample loop to the stripper column. Lighter compounds, such as H 2 and CO, elute quickly from the stripper column into the analytical column, while higher molecular weight components such as hydrocarbons and moisture elute very slowly from the stripper column. After the light components have had sufficient time to elute from the stripper column into the analytical column, the 10-port valve returns to the load position. In addition to preparing the analyzer for the next sample injection, this valve position is used to backflush the higher molecular weight components from the stripper column to vent. Backflushing of the stripper column accomplishes two objectives. It shortens the analysis time and it vents contaminants which can produce an unstable baseline away from the detector. Oxygen and nitrogen from the air will elute through the analytical column. However these components do not interfere with the determination of H 2 and CO because of the chromatography and the selectivity of the RGD. Ethylene Oxide in Ambient Air The presence of ethylene oxide in ambient and indoor air should be monitored at less than the OSHA regulatory limit of one ppm to reduce the possibility of cancers in workers exposed to it. A Reduction Gas Detector, with appropriate injection system and columns, responds to ethylene oxide at 20-30 ppb in ambient air (Table I and Figure 1). In the RGD determination of ethylene oxide, a 10-port valve and a 1 ml sample loop is in the flow path of continuously flowing ambient air. The valve rotates to inject the sample to a stripper column, (inorganic phase). Light components, such as oxygen, are diverted from the stripper column to vent using a 4-port valve located downstream from the 10-port valve. After the oxygen elutes from the stripper column, this 4-port valve is programmed to return to its original position to transfer ethylene oxide to the analytical column (HayeSep). In this way, the 10-port valve and the 4-port valve divert the oxygen, carbon monoxide, and hydrogen to vent and away from the analytical column and RGD detector. The 10- port valve is programmed to return to its original sampling position once the ethylene oxide has been transferred to the analytical column, and at the same time, puts the stripper column in backflush mode to prevent the build up of moisture. The total cycle time between sequential injections in this work is 500 seconds (8.3 minutes). Table I summarizes the results obtained generating different concentrations.

JPACSM 20 Table I EtO in Air Analytical Data EtO (ppb) Peak Area Average %SD 2100 481,313 2100 468,380 466,856 3.27 2100 450,875 700 149,658 700 146,872 150,658 2.90 700 155,444 50 11,568 50 13,864 12,096 13.00 50 10,856 Figure 2 shows a typical spectrum with less than 1 ppm EtO. A 10-port valve is used to inject sample from the sample loop to the stripper column. Lighter compounds such as H 2 and CO, elute quickly from the stripper column into the analytical column while higher molecular weight components, such as hydrocarbons (principally ethylene and propylene) and moisture remain in the stripper column. After the light components have had sufficient time to elute from the stripper columns into the analytical column, the 10-port valve returns to the load position. In addition to preparing the analyzer for the next sample injection, the valve in this position is used to backflush the higher molecular weight components from the stripper columns to vent. As mentioned previously, backflushing of the stripper column to vent shortens the analysis time and vents contaminants which can produce an unstable baseline. Figure 3 shows a typical sample of propylene when the backflush is set after the ethylene peak; in the case of high ethylene concentrations, the backflush should be set before the ethylene peak to avoid excessive consumption of the mercury oxide bed. Figure 2. Typical chromatogram of about 0.8 ppm EtO in air. PROCESS APPLICATIONS H 2 and CO in Ethylene or Propylene Making polyethylene or polypropylene from ethylene or propylene requires a catalyst, such as the Ziegler- Natta polymerization catalyst. The performance of this catalyst is adversely affected by CO, and it is of interest to determine this component at the ppb levels. In this analysis, the RGD is used to provide rapid and reproducible CO measurements 10. Unsaturated hydrocarbons give strong response in the RGD. When ethylene or propylene is a major component in the sample, it can overload the RGD as well as the analytical column, producing a long tailing peak that requires a long time to return to baseline. This application package is designed to overcome interference from the major unsaturated component by using special plumbing and column configuration. Nitrogen carrier gas is used because it gives a minimum of upset in the baseline from the injection, is inexpensive, and readily available. Figure 3. Propylene sample with trace level of H 2, CO, and ethylene. The RGD is also sensitive to phosphine, arsine, and carbonyl sulfide, additional impurities that can adversely affect catalyst performances, as shown in Figure 4.

JPACSM 21 RGD millivolt response 200 150 100 50 0 CO PH3 18 ppb AsH3 27 ppb COS 0 100 200 300 retention time (sec) Figure 4. CO, PH 3, AsH 3, and COS in propylene H 2 and CO in Ammonia Ammonia purity used in the production of light emitting diodes or diode lasers is becoming more and more important to a successful manufacturing operation. Setting the injection system in a way similar to the one mentioned previously, letting H 2 and CO pass over a stripper column and trapping NH 3, allows the analysis of H 2 and CO at trace level to be easily performed. As shown in Figures 5 and 6, the calibration performed generating various concentrations in the 10-1000 ppb range provided good linear results and allowed detection in the range of 10 ppb. peak area (counts) 1.E+05 8.E+04 6.E+04 4.E+04 2.E+04 y = 79.265x R 2 = 0.999 0.E+00 0 200 400 600 800 1,000 1,200 inlet concentrations (ppb) Even better results, in terms of sensitivity, can be obtained for less reactive matrix gases such as Ar, N 2, H 2, O 2, and CO 2. Figure 7 shows a chromatogram of about 1 ppb H 2 and CO in a sample of ultra pure nitrogen 11-13. RGD Signal (counts) 50,000 49,000 48,000 47,000 46,000 45,000 44,000 Detector Auto Zero Normal Valve Pressure Switch H 2 43,000 0 50 100 150 200 250 300 Time (seconds) 1 ppb Figure 7. One ppb H 2 and CO in ultra pure N 2. CONCLUSIONS Some applications of a Reduction Gas Detector for gas chromatography have been briefly discussed. Even if the RGD is not commonly used for the detection of organic compounds, it offers several advantages over the more traditional FID, such as a sensitivity about 50-100 times better and the lack of a requirement for service gases such as air or hydrogen. The data presented in this paper were obtained with packed column; however, the low carrier gas flow rate required for its operation, 10 ml/minute, makes it suitable for use in combination with capillary columns, therefore allowing use for other applications. CO Figure 5. H 2 calibration in an ammonia sample. 3.E+06 peak area (counts) 3.E+06 2.E+06 2.E+06 1.E+06 y = 3569.5x R 2 = 0.9994 5.E+05 0.E+00 0 100 200 300 400 500 600 700 800 900 concentration (ppb) Figure 6. CO calibration in an ammonia sample.

JPACSM 22 REFERENCES 1. R.F. Hickey and M.S. Switzenbaum, Environmental Science and Technology, 24, 11, 1642-1648, (1990). 2. D.W. Smith, A.O. Hopper, et al, J. Of Pediatric Gastroenterology and Nutrition, 3, 77-80, (1984). 3. C.P.R. Ostrander, D.K. Stevenson, et al, Analytical Biochemistry, 119, 378-386, (1982). 4. H.J. Vreman, L.M. Baxter, R.T. Stone, and D.K. Stevenson, Chinical Chemistry, 42, 1, 50-56, (1996). 5. M. Khalil and R.A. Rasmussen, JAPCA, 38, 901-906, (1988). 6. Xu-Liang Cao, C.N. Hewitt, and K.S. Waterhouse, J. of Chromatography, A, 679, 115-121, (1994). 7. Xu-Liang Cao, C.N. Hewitt, and K.S. Waterhouse, Analytica Chimica Acta, 300, 193-200, (1995). 8. H. B. Singh, M. Kanakidou, P.J. Crutzen, and D.J. Jacob, Nature, 378, 2, November, (1995). 9. D. O'Hara, and H.B. Singh, Atmospheric Environment, 22, 11, 2613-2615, (1988). 10. G. Frising, F. Testoni, V. Furlan, and C. Ostrander, LC GC Int., 8, 2, February, (1995). 11. R.G. Ridgeway, S.N. Ketkar, J.V. Martinez, and C.R. Ostrander, Microcontamination Conference Proceedings, November, (1991). 12. R.G. Ridgeway, S. Ketkar, and J.V. Martinez, Technology Circuit, 1, 3, (1992). 13. S. Guadagnuolo and L. Pusterla, PITTCON 2000, paper 350. 14. J.G. Moncur, PITTCON 2000, paper 917.