Elemental Scientific. Spike Recovery. Elemental Scientific

Similar documents
Elemental Scientific. Stability. Elemental Scientific

Elemental Scientific. Spike Recovery. Elemental Scientific

Using cold vapor generation atomic absorption to determine mercury impurities in pharmaceutical products

Automated, intelligent sample preparation: Integration of the ESI prepfast Auto-dilution System with the Thermo Scientific icap 7400 ICP-OES

Automated Determination of PPQ Levels of Thorium in High Purity Copper

High Throughput Water Analysis using Agilent 7900 ICP-MS coupled with ESI prepfast

Validating performance of an Agilent 7800 ICP MS for USP <232>/<233> & ICH Q3D/Q2(R1): Elemental Impurity Analysis in Pharmaceuticals

Authors: C. Derrick Quarles, Jr. *, Patrick Sullivan, M. Paul Field, Hwan Kim, and Daniel R. Wiederin

High-Speed Environmental Analysis Using the Agilent 7500cx with Integrated Sample Introduction System Discrete Sampling (ISIS DS)

Total Elemental Analysis of Food Samples for Routine and Research Laboratories, using the Thermo Scientific icap RQ ICP-MS

Key Analytical Issues: Sample Preparation, Interferences and Variability. Tim Shelbourn, Eli Lilly and Company

Enhancing the productivity of food sample analysis with the Agilent 7700x ICP-MS

á233ñ ELEMENTAL IMPURITIES PROCEDURES

Analysis of high matrix samples using argon gas dilution with the Thermo Scientific icap RQ ICP-MS

Analysis of domestic sludge using the Agilent 4200 MP-AES

Determination of Chromium in Gelatin Capsules using an Agilent 7700x ICP-MS

Multi-Element Analysis of Cannabis using the Agilent 7800 ICP-MS

RISK ASSESSMENT, IMPLEMENTATION AND VALIDATION OF ELEMENTAL IMPURITIES FOR ICH Q3D, USP <232><233> AND EP 5.20

ICP/MS Multi-Element Standards

Proposed new USP general chapters <232> and <233> for elemental impurities: The application of ICP-MS for pharmaceutical analysis

Simple and Reliable Soil Analysis using the Agilent 7800 ICP-MS with ISIS 3

Trace Analyses in Metal Matrices Using the ELAN DRC II

Simultaneous ICP-MS in the Pharmaceutical Industry

Total elemental analysis of food samples for routine and research laboratories using the Thermo Scientific icap RQ ICP-MS

Concept of Elemental Impurities (EI) assessment in finished dosage forms by total extraction testing

Direct Measurement of Metallic Impurities in 20% Ammonium Hydroxide by 7700s/7900 ICP-MS

Samples compliant with the WATER

The Determination of Toxic, Trace, and Essential Elements in Food Matrices using THGA Coupled with Longitudinal Zeeman Background Correction

Ultra-fast determination of base metals in geochemical samples using the 5100 SVDV ICP-OES

Automating Sample Purification MC-ICPMS. Elemental Scientific ICP ICPMS AA

hydrideicp Hydride Generation System

Determining Elemental Impurities in Pharmaceutical Materials: How to Choose the Right Technique

Direct Analysis of Trace Metal Impurities in High Purity Nitric Acid Using ICP-QQQ

Determination of Impurities in Silica Wafers with the NexION 300S/350S ICP-MS

Application of the Agilent 7900 ICP-MS with Method Automation function for the routine determination of trace metallic components in food CRMs

The Agilent 7700x ICP-MS Advantage for Drinking Water Analysis

Analysis of noble metals at low levels in geological reference materials and ores

Thermo Scientific icap RQ ICP-MS: Typical limits of detection

Elemental analysis of river sediment using the Agilent 4200 MP-AES

Maintenance with OQ. ZEEnit 700. Operational Qualification OQ within the scope of a maintenance for the. Atomic Absorption Spectrometer

Simple, reliable analysis of high matrix samples according to US EPA Method 6020A using the Agilent 7700x/7800 ICP-MS

Analytical Method Determination of airborne metal concentrations by ICP-MS Sampling using Solu-Sert filter capsules

Application. Determination of Trace Metal Impurities in Semiconductor-Grade Hydrofluoric Acid. Authors. Introduction. Abstract.

Rapid and precise calcium isotope ratio determinations using the Apex-ACM desolvating inlet system with sector-field ICP-MS in low resolution

Determination of trace elements in ultrapure semiconductor grade sulfuric acid using the Agilent 8900 ICP-QQQ in MS/MS mode

Today s Agilent Solutions for Determining Heavy Metals in Food using Atomic Spectroscopy

Meeting the Challenges of Soil Analysis with the Avio 200 ICP-OES

DISCLAIMER: This method:

Fast Analysis of Water Samples Comparing Axially-and Radially- Viewed CCD Simultaneous ICP-OES

Strategies for Determination of Elemental Impurities in Complex Samples

ICP-OES Application Note Number 35

Determination of ultratrace elements in photoresist solvents using the Thermo Scientific icap TQs ICP-MS

Determination of major, minor and trace elements in rice fl our using the 4200 Microwave Plasma- Atomic Emission Spectrometer (MP-AES) Authors

Dissolution Automation: Basic Questionnaire.

PQRI Technical Analytical Challenges Round 2 Interlaboratory Study: Progress and Early Findings

On the use of Deming and quadratic calibrations in analytical chemistry

Examples of Method Validation Studies Conducted in Different Economies

China Soil Pollution Survey: Elemental Analysis of Soil and Sediment Digests by ICP-MS

ICH Q3D: Practical implementation and the role of excipient data in a risk based approach. Dr Andrew Teasdale

Using FIMS to Determine Mercury Content in Sewage Sludge, Sediment and Soil Samples

Semiquantitative Screening of Pharmaceutical Antiviral Drugs using the Agilent 7500ce ICP-MS in Helium Collision Mode

NOTICE: This method: The laboratories have to study the instrumental conditions appropriate for their own instrumentation.

Traceability, validation and measurement uncertainty 3 pillars for quality of measurement results. David MILDE

Multi-Element Analysis of Petroleum Crude Oils using an Agilent 7900 ICP-MS

February 20, Joe Cerniglia The International Group for Historic Aircraft Recovery (TIGHAR) Job Number: S0CHG688. Dear Joe:

Single-Element Standards for AAS

Introduction to E&Ls 1

BECKMAN COULTER QbD1200 Total Organic Carbon Analyzer Critical Measurements Made Simple

Fusion UV/Persulfate TOC Analyzer

OPTIMIZING METALS SAMPLE PREP

Automation of the radiochemical procedures for the sequential separation of radionuclides

Trace elemental analysis of distilled alcoholic beverages using the Agilent 7700x ICP-MS with octopole collision/ reaction cell

Fusion UV/Persulfate TOC Analyzer

Ionic Compound Solubility. Ionic Compound Solubility. Nitrates (NO 3 - ) Chlorates (ClO 3 - ) Ionic Compound Solubility. Ionic Compound Solubility

Multi Analyte Custom Grade Solution. Calcium, Iron, Potassium,

Applications of ICP-MS for Trace Elemental Analysis in the Hydrocarbon Processing Industry

High-Throughput Semiquantitative Screening of Ambient Air Samples by ORS-ICP-MS and Integrated Sample Introduction System (ISIS) Application

3. Chemical industry. Because of their modular design, the instruments in the TOC-L series can be equipped for any possible measurement

Rapid Detection of Americium-241 in Food by Inductively-Coupled Plasma Mass Spectrometry

Determination of Pb, Cd, Cr and Ni in Grains Based on Four Chinese National Methods via Zeeman GFAAS

icap TQ ICP-MS Applications Compendium

Fundamentals of the ICP-MS Technique and How to Resolve Issues for Pharmaceutical Materials (In 20 Minutes) Tim Shelbourn, Eli Lilly and Company

Elemental Impurity Analysis: Technical Challenges and Overview of an Inter-laboratory Study PQRI Elemental Impurities Workshop March 31, 2015

Level. Automate your processes Automate your lab Innovate with. sensing. EasyPREP. sample handler. Automated Sample Preparation.

CERTIFICATE OF. Single Analyte Mass Spec Solution ± 0.1 µg/ml g/ml (measured at 20 ± 4 ºC)

Analysis of trace elements in polymer samples to ensure compliance with WEEE-RoHS standards using the Thermo Scientific icap 7200 ICP-OES

7) Applications of Nuclear Radiation in Science and Technique (1) Analytical applications (Radiometric titration)

ICP-3000 Inductively Coupled Plasma Optical Emission Spectrometer

Outsmart Interferences with Triple Quadrupole ICP-MS. The world leader in serving science

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

Air Monitoring. Semi-continuous determination of ambient air quality

Highly sensitive quantitative estimation of genotoxic impurities from API and drug formulation using LC/MS/MS

On-line isotope dilution analysis with the 7700 Series ICP-MS: Analysis of trace elements in high matrix samples

ION CHROMATOGRAPHY SYSTEM S 150

BATTERY INDUSTRY STANDARD ANALYTICAL METHOD

Cyanide Methods for Lachat Automated Ion Analyzers. Flow Injection Analysis

Following documents shall be used for reference on quantities, units, prefixes and other technical vocabulary in this document:

novaa 800 D Atomic Absorption Spectrometer

DETERMINATION OF DRUG RELEASE DURING DISSOLUTION OF NICORANDIL IN TABLET DOSAGE FORM BY USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

METHOD 3010A ACID DIGESTION OF AQUEOUS SAMPLES AND EXTRACTS FOR TOTAL METALS FOR ANALYSIS BY FLAA OR ICP SPECTROSCOPY

Transcription:

Elemental Scientific prepfast ICP-MS: USP <232><233> Oral Drugs by Dissolution Automated Inline Calibration and Sample Dilution Authors: Kyle Uhlmeyer and Paul Field (field@icpms.com) Brief The prepfast inline autodilution system with ICP-MS fully automates USP <233> sample dilutions and J based calibrations. The prepfast automatically 1) dilutes a single stock standard to build linear calibration curves and 2) dilutes samples to the appropriate Total Dissolved Solids (TDS) surpassing all USP <233> validation criteria. Features: Autocalibration from a single J stock standard Spike Recovery USP <233> Definition: Auto Sample Dilution Priority Sample Dilution Daily walk-up and analyze ICP-MS instrument for USP Perfect for laboratories new to ICP-MS Automate labor intensive steps to significantly reduce notebook entries Elemental Scientific Figure 1. Excellent recovery for 1J spike to Naproxen and OTC flu remedy indicates the method is very robust, constantly yielding spike recoveries (< ± 10%) that are significantly better than the USP threshold (70-150%). 1

NexION SC-DX FAST Autosampler NexION PC 3 with SSI Spray Chamber and PFA-ST Nebulizer P7+ S400V Syringe Pump Carrier Diluent I.S. prepfast System for NexION P7+ Load To ICPMS P7+ Inject/Dilute To ICPMS Sample Internal Standard Rinse Internal Standard Carrier Carrier Diluent Diluent Vacuum Vacuum Figure 2. The prepfast system schematic illustrating a two-step process of loading sample into a loop and injecting sample while performing inline dilution. Abstract USP <233> outlines specific protocols for the dissolution and analysis of metal impurities in solid samples. Calibration and validation protocols are based on a target (J) value that is a function of PDE (µg/day), final dilution (0.2% = 500x) and a drugs daily dose (g/day). The prepfast automatically dilutes a single stock standard to build linear calibration (r 2 > 0.999s) for any J value. A 500 fold final dilution factor equates to an appropriate Total Dissolved Solids (TDS) for ICP-MS. Solid samples (1g) initially digested in 50mL of acid are automatically diluted inline 10x by prepfast to obtain a final TDS of 0.2%, eliminating a second manual dilution step. The seamlessly integrated prepfast ICP-MS system easily surpasses USP <233> validation criteria of, 1) stability < ± 5% (USP limit ± 20%), 2) repeatability < ± 3% (USP limit ± 20%), 3) ruggedness < ± 4% (USP limit ± 25%) and 4) accuracy < ±10% (USP limit ± 20%). Automating the full calibration and sample dilution process removes human error and reduces notebook entries simplifying compliance with FDA s 21 CFR Part 11 record integrity regulation. 2

Introduction The oral route has the highest Permissible Daily Exposure (PDE) of all pathways. Oral drugs in the solid phase must first be digested and diluted to an appropriate Total Dissolved Solid (TDS) concentration (0.2%) for ICP-MS analysis. USP <233> outlines protocols for the dissolution of solid drugs. In this study, Over The Counter (OTC) flu remedy powder and Naproxen tablets are digested in an open vessel (warm 50mL 2% HNO 3 / 0.5% HCl) mixture and closed vessel microwave system (50 ml 10% HNO 3 / 2.5% HCl / 2% H 2 O 2 ) mixture, respectively. This equates to a 50 fold dilution of the solid and would either require large volumes of diluent (e.g. 0.2g in 100mL - 1g in 500mL) or a second manual 10 fold dilution step to reach 0.2% TDS. Dilution factors entered into the ICP-MS software are used by prepfast for precise and accurate inline dilutions, thereby eliminating the second manual dilution step. USP <233> outlines specific validation protocols that require standardization, precision and spike recovery to be based on a target (J) value. The prepfast ICP-MS system calibrates and dilutes samples easily fulfilling all acceptance criteria outlined by USP <233>. USP <232> <233> Definition: Table 1. Maximum Permissible Daily Exposure - PDE Element Oral Daily Dose PDE (µg/day) Cadmium 25 Lead 5 Arsenicb (Inorganic) 1.5 Mercuryb (Inorganic) 15 Iridium 100 Osmium 100 Palladium 100 Platinum 100 Rhodium 100 Ruthenium 100 Molybdenum 100 Nickel 500 Vanadium 100 Copper 1000 Table 1. The USP Chapter <232> defined PDE (µg/ day) values for Oral drugs are used (Figure 3) to calculate target values (J). USP <233> requires a calibration curve and a series of QC validation protocols including repeatability, ruggedness and spike recovery be based on the J value. Figure 3. USP <232><233> defined calculation of J using Cd as an example. PDE from Table 1 is combined with a hypothetical daily dose (1g) and a dilution factor of 500. It is clear from this calculation that J value is inversely proportional to the daily dose. 3

OTC Flu Remedy: Closed vessel digested (2% HNO 3, 0.5% HCl) USP <232> <233> Definition: Naproxen: Microwave digested (10% HNO 3, 2.5% HCl, 2% H 2 O 2 ) USP <232> <233> Definition: USP <233> Definition: Standardization solution 1: 2J of the Target Element(s) in a Matched Matrix Standardization solution 2: 0.5J of the Target Element(s) Table 2. J Values for a Range of Daily Doses Isotope PDE (µg/day) 1g/day daily dose J Values in final solution 0.2% TDS (µg/l) 4 5g/day daily dose 20g/day daily dose 0.5J 2J 0.5J 2J 0.5J 2J Cd 111 25 25 100 5 20 1.25 5 Pb 208 5 5 20 1 4 0.25 1 As 75 1.5 1.5 6 0.3 1.2 0.075 0.3 Hg 202 15 15 60 3 12 0.75 3 Ir 193 100 100 400 20 80 5 20 Os 192 100 100 400 20 80 5 20 Pd 106 100 100 400 20 80 5 20 Pt 195 100 100 400 20 80 5 20 Rh 103 100 100 400 20 80 5 20 Ru 102 100 100 400 20 80 5 20 Mo 98 100 100 400 20 80 5 20 Ni 60 500 500 2000 100 400 25 100 V 51 100 100 400 20 80 5 20 Cu 63 1000 1000 4000 200 800 50 200 Table 2. Calculated 0.5 and 2J values for a range of daily doses using formula in Figure 3.

"J" Calibrations - 1g Daily Dose 0.999997 2 J 0.5 J "J" Calibrations - 20g Daily Dose 0.999997 0.999958 2 J 0.5 J Figure 4. Fully automated inline dilutions of a single stock standard are used to generate linear calibration curves. The formula from figure 3 is used to calculate J values for drugs with a wide range of daily doses (1 and 20 g/day are given as examples). 5

"J" Calibration Coefficients 1.000 0.999 Calibration Coefficient 0.998 0.997 0.996 0.995 1g/day 5g/day 10g/day 20g/day V Ni Cu As Mo Ru Rh Pd Cd Os Ir Pt Hg Pb Figure 5. Fully automated inline dilutions from a single stock standard generates linear (>0.9999) calibration curves over a wide range of J values for all USP elements. USP <233> Definition: Repeatability prepfast - ICP-MS RSD < 3% Figure 6. Repeatability for all analytes of interest of < ± 3% at 1J spike in over the counter flu remedy liquid is significantly below the USP accepted criteria of < ± 20% RSD. 6

Ruggedness USP <233> Definition: prepfast - ICP-MS RSD < 4% Figure 7. The ruggedness of the method demonstrated on 3 separate days yields accuracy (recoveries) of < ± 10% and reproducibility of < ± 4%. The USP acceptance criteria is defined as < ± 25% RSD for each target analyte. Isotope PDE (µg/day) Table 3. Results 7 Naproxen µg/day OTC Flu Remedy (Powder) µg/day V 51 100 0.102 1.08 Ni 60 500 0.141 - Cu 63 1000 0.011 - As 75 1.5-0.12 Mo 98 100 - - Ru 102 100 0.006 0.04 Rh 103 100 - - Pd 106 100 - - Cd 111 25 - - Os 192 100 - - Ir 193 100 0.031 - Pt 195 100 - - Hg 202 15 - - Pb 208 5 0.016 0.06 Table 3. Results for OTC flu remedy and naproxen are significantly lower than USP PDEs.

Benefits prepfast All flows syringe-driven - Eliminate peripump tubing daily maintenance prepfast autocalibration - Single multi-element standard for all J values prepfast auto inline dilution - Eliminate final manual dilution step Brings samples to constant total dissolved (0.2%) Easy-to-use automated system for USP protocols Pre-developed fully automated methods Exceeds all USP validation criteria: Stability, Repeatability, Ruggedness, and Accuracy Well-suited to the demands of a high throughput pharmaceutical laboratory SC-2 DX prepfast System 1500 North 24th Street Omaha, NE 68110 USA Phone: 1.402.991.7800 Fax: 1.402.991.7799 Email: prepfast@icpms.com Web: www.prepfast.com www.icpms.com Elemental Scientific