DIMENSIONAL ANALYSIS OF A HIGH POWER ULTRASONIC SYSTEM USED IN ELECTRODISCHARGE MACHINING

Similar documents
Nonconventional Technologies Review no. 4/2011 STUDY ON ULTRASONIC STEPPED HORN GEOMETRY DESIGN AND FEM SIMULATION

ASPECTS CONCERNING FEM MODELLING OF AN ULTRASONIC HORN USED AT MICRO-EDM DRILLING

A method for matching the eigenfrequencies of longitudinal and torsional vibrations in a hybrid piezoelectric motor

ANALYSIS AND NUMERICAL MODELLING OF CERAMIC PIEZOELECTRIC BEAM BEHAVIOR UNDER THE EFFECT OF EXTERNAL SOLICITATIONS

Finite Element Modeling of Ultrasonic Transducers for Polymer Characterization

Study and design of a composite acoustic sensor to characterize an heterogeneous media presenting a complex matrix

Application and analysis of phononic crystal energy harvesting devices

Structural Health Monitoring Using Smart Piezoelectric Material

VIBRO-THERMOGRAPHY OF DEBONDING DEFECTS IN COMPOSITE PLATES

VIBRATION AMPLIFICATION IN OSCILLATING SYSTEMS WITH DEGRADING CHARACTERISTICS *

Lamb Wave Behavior in Bridge Girder Geometries

Analysis of the conical piezoelectric acoustic emission transducer

On the study of elastic wave scattering and Rayleigh wave velocity measurement of concrete with steel bar

Lamb Waves in Plate Girder Geometries

1106. Numerical investigation of dynamical properties of vibroactive pad during hot imprint process

ULTRASONIC WELDING OF COMPOSITE MATERAILS. ULTRASONIC BOOSTER DESIGN AND FEM SIMULATION

Development of the Screw-driven Motors by Stacked Piezoelectric Actuators

PIEZOELECTRIC TECHNOLOGY PRIMER

NON-LINEAR ATTENUATION EFFECTS ON SOILS DYNAMIC RESPONSE EVALUATION *

Lecture 19. Measurement of Solid-Mechanical Quantities (Chapter 8) Measuring Strain Measuring Displacement Measuring Linear Velocity

SHM for RC Structure Using PZT Rebar Active Sensing System - Numerical Study

ME 475 Modal Analysis of a Tapered Beam

Differential Acoustic Resonance Spectroscopy Analysis of Fluids in Porous Media

Eigenvalues of Trusses and Beams Using the Accurate Element Method

SERVICE LIFE ESTIMATION FOR RUNNER S BLADE OF AN AXIAL TURBINE

A model for the ultrasonic field radiated by an Electro-Magnetic Acoustic Transducer in a ferromagnetic solid

Doppler echocardiography & Magnetic Resonance Imaging. Doppler echocardiography. History: - Langevin developed sonar.

Thickness Optimization of a Piezoelectric Converter for Energy Harvesting

440. Simulation and implementation of a piezoelectric sensor for harmonic in-situ strain monitoring

433. New linear piezoelectric actuator based on traveling wave

Analysis of Different Shaped Sonotrodes used for Plastic Welding

Piezoelectric Resonators ME 2082

Chapter 2 Surface Acoustic Wave Motor Modeling and Motion Control

19 th INTERNATIONAL CONGRESS ON ACOUSTICS MADRID, 2-7 SEPTEMBER 2007

FINITE ELEMENT MODELLING OF AN ULTRASONIC ROTARY MOTOR

Analysis of a Piezoelectric Sensor to Detect Flexural Waves

SENSORS and TRANSDUCERS

Strength of Material. Shear Strain. Dr. Attaullah Shah

Increasing of the Stern Tube Bushes Precision by On-Line Adaptive Control of the Cutting Process

Thermal Analysis of a piezo-disk ultrasound probe

Single-phase driven ultrasonic motor using two orthogonal bending modes of sandwiching. piezo-ceramic plates

FIELD MODELS OF POWER BAW RESONATORS

DEVELOPMENT OF A BAR-SHAPED ULTRASONIC MOTOR FOR MULTI-DEGREES OF FREEDOM MOTION

Available online at ScienceDirect. Physics Procedia 70 (2015 )

Design of a compact six-component force and moment sensor for aerodynamic testing

Piezo materials. Actuators Sensors Generators Transducers. Piezoelectric materials may be used to produce e.g.: Piezo materials Ver1404

Prob. 1 SDOF Structure subjected to Ground Shaking

SOME RESULTS OF FINITE ELEMENT MODELLING OF LASER BEAM MICRO-MACHINING AIDED BY ULTRASONICS

Analysis of the conical piezoelectric acoustic emission transducer

Sound Propagation through Media. Nachiketa Tiwari Indian Institute of Technology Kanpur

Compensation-based non-destructive automatic quality control using acoustic methods

An Approach to Designing a Dual Frequency Piezoelectric Ultrasonic Transducer

Measurements of Radial In-plane Vibration Characteristics of Piezoelectric Disk Transducers

Borehole Geophysics. Acoustic logging measurements

Virtual Prototyping of Electrodynamic Loudspeakers by Utilizing a Finite Element Method

VIBRATION ENERGY FLOW IN WELDED CONNECTION OF PLATES. 1. Introduction

Measuring vibration characteristics at large amplitude region of materials for high power ultrasonic vibration system

The Torsion Pendulum (One or two weights)

Transverse vibrations analysis of a beam with degrading hysteretic behavior by using Euler-Bernoulli beam model

Proceedings Effect of Electrode Configuration on High Temperature Thickness Shear Gallium Phosphate Transducer

PROPERTY STUDY ON EMATS WITH VISUALIZATION OF ULTRASONIC PROPAGATION

ON THE PREDICTION OF EXPERIMENTAL RESULTS FROM TWO PILE TESTS UNDER FORCED VIBRATIONS

COMPARISON OF DEFECT DETECTION IN ALUMINUM AND STEEL PLATES USING AN ELECTROMAGNETIC ACOUSTIC TRANSDUCER

NUMERICAL EVALUATION OF A TEFLON BASED PIEZOELECTRIC SENSOR EFFECTIVITY FOR THE MONITORING OF EARLY AGE COCRETE STRENGTHING

ON THE MODELING AND SIMULATION OF AN ACOUSTIC CLOAK

A Sample Durability Study of a Circuit Board under Random Vibration and Design Optimization

THE IMPEDANCE SIGNATURE METHOD FOR IMPEDANCE-BASED STRUCTURAL HEALTH MONITORING

1859. Forced transverse vibration analysis of a Rayleigh double-beam system with a Pasternak middle layer subjected to compressive axial load

Effect of Plasticity on Residual Stresses Obtained by the Incremental Hole-drilling Method with 3D FEM Modelling

MODELLING OF RECIPROCAL TRANSDUCER SYSTEM ACCOUNTING FOR NONLINEAR CONSTITUTIVE RELATIONS

SUBSURFACE WAVES IN SOLIDS WITH CURVED SURFACE AND ACOUSTICAL IMPEDANCE ON IT

The velocity (v) of the transverse wave in the string is given by the relation: Time taken by the disturbance to reach the other end, t =

Fig. 1. Circular fiber and interphase between the fiber and the matrix.

Post Graduate Diploma in Mechanical Engineering Computational mechanics using finite element method

AS PHYSICS (7407/2) Paper 2. Specimen 2014 Morning Time allowed: 1 hour 30 minutes SPECIMEN MATERIAL

Fatigue Crack Analysis on the Bracket of Sanding Nozzle of CRH5 EMU Bogie

PHASED-ARRAY FOCUSING WITH LONGITUDINAL GUIDED WAVES IN A VISCOELASTIC COATED HOLLOW CYLINDER

UNIVERSITY OF SOUTHAMPTON

Measurement of Structural Intensity Using an Angular Rate Sensor

Sound Propagation through Media. Nachiketa Tiwari Indian Institute of Technology Kanpur

Load Cell Design Using COMSOL Multiphysics

EQUIVALENT FRACTURE ENERGY CONCEPT FOR DYNAMIC RESPONSE ANALYSIS OF PROTOTYPE RC GIRDERS

IMPROVING THE ACOUSTIC PERFORMANCE OF EXPANSION CHAMBERS BY USING MICROPERFORATED PANEL ABSORBERS

DYNAMIC ROTARY TORQUE MEASUREMENT USING SURFACE ACOUSTIC WAVES

Tightening control by ultrasound

Engineering Failure Analysis

where d is the vibration direction of the displacement and c is the wave velocity. For a fixed time t,

VIBRATION ANALYSIS OF E-GLASS FIBRE RESIN MONO LEAF SPRING USED IN LMV

EVALUATING DYNAMIC STRESSES OF A PIPELINE

NDT&E Methods: UT. VJ Technologies CAVITY INSPECTION. Nondestructive Testing & Evaluation TPU Lecture Course 2015/16.

Rock fragmentation mechanisms and an experimental study of drilling tools during high-frequency harmonic vibration

MOOC QP Set 2 Principles of Vibration Control

Part 7. Nonlinearity

VIBRATION CONTROL OF RECTANGULAR CROSS-PLY FRP PLATES USING PZT MATERIALS

Finite Element Method in Geotechnical Engineering

SPECIAL DYNAMIC SOIL- STRUCTURE ANALYSIS PROCEDURES DEMONSTATED FOR TWO TOWER-LIKE STRUCTURES

Part 5 ACOUSTIC WAVE PROPAGATION IN ANISOTROPIC MEDIA

Sound radiation and sound insulation

Available online at ScienceDirect. Physics Procedia 63 (2015 ) 54 60

SURFACE ACOUSTIC WAVE FERROELECTRIC PHONONIC CRYSTAL TUNABLE BY ELECTRIC FIELD

Transcription:

Nonconventional Technologies Review Romania, March, 2012 2012 Romanian Association of Nonconventional Technologies DIMENSIONAL ANALYSIS OF A HIGH POWER ULTRASONIC SYSTEM USED IN ELECTRODISCHARGE MACHINING Cristian RUGINA, Institute of Solid Mechanics, Romanian Academy, Bucharest, Romania, cristi@imsar.ro ABSTRACT: This paper dissses the theoretical and computational aspects of designing a 19kHz high power ultrasonic system used as supplement in electro discharge machining (EDM) systems. A theoretical part presents a numerical approximative 1D matrix method for computing the mechanical resonance frequency of components of ultrasonic systems with axial symmetry. The results obtained by this method, in the case of the concentrator part of the ultrasonic system, are compared with the one obtained from finite element method. A finite element analysis, with computation of the resonance frequency of mechanical vibrations mode around 19kHz, is also presented for the high power ultrasonic transducer and for the entire ultrasonic system. KEY WORDS: high power ultrasonic system, resonance frequency. 1. INTRODUCTION The analysis of ultrasonic systems is generally done both from the electrical [1], [5], [6], [8], [9], [10] and mechanical [1], [2], [], [4], [7], [8], [11] point of view for an optimal coupling between the electronic generator and the acoustic chain, in terms of power and efficiency. In industrial applications, however, a specific working frequency is needed. And so the mechanical analysis concerning dimensioning of all the elements of the high power ultrasonic systems, and finding the nodal planes, at a given resonance frequency, is also needed. An ultrasonic chain is composed by several elements with capabilities of concentrating or scattering the ultrasonic energy. One key element is the ultrasonic transducer that generate the ultrasonic energy, and composed by a backing part, the reflector, that reflect the ultroasonic energy, an active part, that trnsmit ultrasonic enery to the active tool, 2 piezoceramic rings, and 2 copper electrodes for connection to the elecronic generator, all of them prestresed with a central screw. The second key element is the active tool,, the concentrator, that guide the ultrasonic energy to the industrial process. This two parts are linked by a link screw, as seen in figure 1. O course the active part of the transducer and the concentrator can be done in one piece, but is better to make them separately, so the active tool, the concentrator, that is more rapidely wear in the industrial process, can be interchangeable. Every ultrasonic system must have a specific resonance frequency, given by the industrial process requirements, and so a dimensional analysis must be done. All these elements are longitudinal resonators in half wavelength with continuous or step variations of the cross-section. Most of them have a cirlar cross-section, that enables an approximative 1D numerical matrix method, presented below, or 2D finite element dimensional analysis with axial symmetry. This paper presents the case of the dimensional analysis of a high power ultrasonic acoustic chain resonator, used in the electrodischarge machining industrial porocess, called EDM, with both the piezoceramic transducer and concentrator used in the industrial process of electro-discharge machining, at a required frequency of 18kHz-20kHz. Both the transducer and the resonator elements are analyzed separately and as an assembly respectively, in order to find the precise resonance frequency. 2. THE NUMERICAL MATRIX METHOD The numerical method used is the 1D matrix method. This numerical method considers the free longitudinal wave propagation analysis can be performed using equation of wave propagation in a dissipative media: 2 2 w w w E = ρ + R (2.1) 2 2 x t t where w - represents the displacements, x - the direction of propagation, t - the time, ρ - mass density, E - the modulus 2 of elasticity, E = ρc, c - the wave speed and R - the coefficient of friction that characterize the losses in the media. For stationary waves the solution of (2.1) can be written: (, ) ( ) ( ) w x t = X x P t (2.2) One can consider for each straight portion of the beam, with length l and i and j its extreme sections indexes. In each section of abscissa x, it can be defined the column matrix named state vctor: W( x) { M( x) } = T( x) (2.) where W ( x ) and T( x ) represents the displacements and stress in the Ox direction. For the monochromatic wave of frequency αt f = ω/2π, it can be considered Pt () = e cos( ωt ϕ ) where α represent the atenuation factor, and ϕ the phase shift, and so (2.2) becomes: α (, ) ( ) t cos( ) w x t = X x e ωt ϕ (2.4) For R = 2αρ eq. (2.1) becomes and ordinary differential equation: 1 2 2 X ( x) + 2 ( ω +α ) X ( x) = 0 (2.5) c 4

A matricial equation between the state vectors of sections i and j can be considered: W W j i M ij T = j T (2.6) i or briefly: { M } M j ij { M i} = (2.7) where M ij is named field matrix and has the form: 1 cos al sin al M ij = kal kal sin al cos al where : (2.8) a ω ω +α c c 2 2 a = =, E c =, ρ EA k =, (2.9) l with ω - the angular frequency, c - the wave speed, k - the stiffness of the (i,j) medium of length l. For an entire uniaxial structure, a global matricial equation between the state vectors of both ends with indexes 1 and n: { M } = [ M]{ M } n 1, where the matrix [ M ] is given by: [ M] = M ( n 1) n M ( n 2)( n 1) [ M2][ M12] (2.10). (2.11) The element of the global matrix [ M ], are function of angular frequency: [ M ] m ( ω) m ( ω) ( ω) m ( ω) 11 12 = m21 22. (2.12) At the longitudinal resonance the stress on both ends of the structure must be null T n = 0, and T 1 = 0, that implies: m21 ( ω ) = 0. (2.1) Equation (2.1) can be solved numerically without diffilties. It also can be seen that the longitudinal disctretization do not need to be uniform. However when the cross-section is not uniform, a large number of setions must be taken into account to approximate as good as possible the contour of the resonator.. RESULTS An acoustic chain used in ultrasonic assisted EDM, as presented in figure 1, has been analyzed. First, the two elements of the acoustic chain, the concentrator and the high power ultrasonic transducer are analyzed separately, and then analyzed assembled. The requirement is that the two parts of the ultrasonic system must be half wavelength resonators. The industrial EDM process requires that the resonance frequency must be between 18kHz and 20kHz. Figure 1. Acoustic chain used in ultrasonic assisted EDM 5

First the concentrator, is analyzed with both numerical methods the 1D matrix method and the finite element method, and after that only the finite element method for the transducer and the assembled acoustic chain. In figure 2 the geometric dimensions of the concentrator and in figure the geometric dimensions of the high power ultrasonic transducer are presented. Figure 2. The concentrator of the acoustic chain used in ultrasonic assisted EDM. Figure 4. Mesh used in finite element analysis of the concentrator. Figure. The transducer of the acoustic chain used in ultrasonic assisted EDM. Figure 5. First vibration computed mode of the concentrator. 6

The finite element analysis of the transducer was considered in 2 cases of the resonance frequency: the first case when the electrodes are in short cirit that corresponds to the series resonance frequency, and, in the second case, when the electrodes are in the gap that corresponds to the parallel resonance frequency. Figure 6. Second vibration mode computed of the concentrator. The matrix method descripted above was applied to the considered concentrator, resulting a resonance frequency of 18.724 khz. It has been taken a discretization of 2005 section of constant cross-setion, and elastic modulus and mass density of the umin and copper has been taken E = 71.0[ MPa], E = 117.0[ MPa], ρ = 2700[ kg / m ], 8940[ kg / m ] ρ =. This method is very fast, being onedimensional, but somewhat imprecise because it does not takes into account shear elastic properties, like the shear modulus or Poisson ratio, of the uminium and copper. It is therefore necessary, for comparison, an analysis with the finite element method specialized software Comsol 4.2. In finite element method analysis, the elastic characteristics (modulus of elasticity, mass density and Poisson ratio, of the umin and copper) have been taken also E = 71.0[ MPa], E = 117.0[ MPa], ρ = 2700[ kg / m ], 8940[ kg / m ] ρ =, ν = 0., respectively ν = 0.. If the the gathering holes are neglected, the acoustic chain element presents axial symmetry, and the finite element analysis can be done in the 2D-axisymmetric case, on a half longitudinal cross-section computing the eigenfrequencies of the structure. The mesh discretization has been taken normal, and can be seen in figure 4, and firsts eigenfrequencies have been computed around 19 khz. In figures 5 and 6 the vibration modes corresponding to frequencies 1802.29 Hz, 7846.95 Hz, are presented. Obviously only the first vibration mode corresponding to the longitudinal resonance is interesting. The callation was made, for comparison, with a finer the grid mesh, but the difference between resonance frequencies corresponding to the first vibration mode did not exceed 10 Hz, leading to differences due to discretization of 0.05%, total considered negligible. Of course if the materials properties are taken slightly different, the difference between the resonance frequencies are bigger, but also neglijable. Figure 7. Mesh used in finite element analysis of the transducer. Figure 8. First vibration mode computed of the transducer. 7

- Relative permitivity matrix ε r 762.5 0 0 = 0 762.5 0. 0 66.2 The mesh has been taken normal, as presented in figure 7, and the firsts vibration modes have been computed around 19000 Hz. In figures 8 and 9, corresponding to vibration modes at frequencies 19418.14Hz and 41167.95Hz for the series resonance of the transducer, with electrodes in short cirit, are presented. Only the pure longitudinal vibration mode is interesting, the one with higher vibration amplitudes, at the 19418.14 Hz. For the parallel resonance, similar vibration modes are obtained, but the resonance frequencies are respectively 20597.67Hz and 4157.Hz, far enough for the series resonance frequency, so that the elecronic generator to excite that modes, that can damage both the transducer and the electronic generator. Figure 9. Second vibration mode computed of the transducer. In the finite element analysis of the transducer the elastic properties of the steel, umin and copper electrodes have been taken Est = 210.0[ MPa], E = 71.0[ MPa], E = 117.0[ MPa], ρ st = 7800[ kg / m ], 2700[ kg / m ] ρ =, ρ = 8940[ kg / m ], ν = 0., ν = 0., ν = 0. respectively. st For the piezoceramic rings the elastic and piezoelectric constants are the ones o the PZT-4, with symbols given by the constitutive equarions: T σ = ceε e E D = eε + εεe 0 r - Mass density ρ = 7500[ kg / m ], - Elasticity matrix c E 18.99 77.8 77.8 0 0 0 18.99 77.8 0 0 0 115.41 0 0 0 = [MPa] 25.64 0 0 25.64 0 0.58 - the piezoceramic matrix constants have been taken for normal and reverse polarization (The two piezoceramic rings are mirror mounted, for bigger vibration amplitude): 0 0 0 0 12.718 0 2 e = 0 0 0 12.718 0 0 C/m -5.2028-5.2028 15.080 0 0 0 0 0 0 0-12.718 0 2 e = 0 0 0-12.718 0 0 C/m 5.2028 5.2028-15.080 0 0 0 Figure 10. Mesh used in finite element analysis of the entire ultrasonic system. In the dimensional analysis of the acoustic chain with finite element method, the same discretization "normal" was taken, as seen in figure 10. In this case, also, the vibration mode, presented in figures 11 and 12, were computed around 19 khz, and for series resonance and their frequencies are 9910.18 Hz and 1825.14Hz. For parallel resonance, the vibration modes are obtained similar, but that resonance frequencies are 1006.51Hz and 18599.81Hz. It can be seen a decrease in the frequency of resonance of acoustic chain, from those two parts. This is due to added link screw that connects all the components. 8

nodal plane Figure 11. First vibration mode computed of the entire ultrasonic system. nodal plane Obviously we are interested only pure longitudinal vibration mode. It can be seen that there are two modes of vibration of this type. The nodal planes corresponding to these two vibration modes are different. The vibration mode corresponding to the frequency 9910.18Hz, is in half wavelenght, for the entire acoustic chain. It seems more convenient, but it is sonic not ultrasonic, which can be annoying, for the human ear. We must therefore choose one of them as a way of working, the one corresponding to the frequency 1825.14 Hz. 4. CONCLUSIONS The 1D numerical matrix method approximates well enough the resonance frequency of the elements of the ultrasonic system. Dimensional analysis of the ultrasonic chain meets the requirements imposed by the electronic generator and the of the electrodischarge machining process, the ones that pure longitudinal vibration mode corresponding to the series resonance frequency being between 18kHz and 20kHz. 5. ACKNOWLEDGEMENTS The author gratefully acknowledges the financial support of ANCS/UEFISCDI for PN-II grant no. 72194/2008. 6. REFERENCES 1. G.L. Gooberman., Ultrasonics - Theory and Application, 5 th edition, The English Universities Press LTD, London, (1968). 2. P.D. Edmonds, Ultrsonics, Academic Press, (1981).. Puskar A., The use of high - intensity ultrasonics, Elsevier Co., Amsterdam, (1982). 4. O. Dragan, et al., Ultrasunete de mari energii, Editura Academiei, Buresti, (198). 5. J.M. Herbert, Ferroelectric Transducers and Sensors, London Publishers, (1984). 6. Gh. Amza, D. Barb., F. Constantines, Sisteme ultraastice, Editura Tehnica, Buresti, (1988). 7. M. Scheffel., P. Stiuca., Dispozitive ultrasunete, Editura Tehnica, Buresti, (1989). 8. C. Rugina, Simularea numerica a ultrasunetelor in controlul nedistructiv si in aplicatiile de putere, Editura Academiei, (2008). 9. I. Rugina, N. Bajea, G. Winter, Optimization of the high intensity ultrasonic transducer efficiency, The Annual Symposium of the Institute of Solid Mechanics, p.21-26, Bucharest, (1982). 10. I. Rugina, C. Rugina, Motion rrent essential parameter for ultrasonic piezoceramic transducers characterization, The Annual Symposium of the Institute of Solid Mechanics, p.155-162, (199). 11. I. Rugina, G. Winter, N. Bajea, Dimensional analysis of ultrasonic system components consisting of sections with acoustic impedances varying by steps, Rev. Roum. Sci. Techn - Mec. Appl., Tome 9, No, p. 05-18, Bucharest, (1994). Figure 12. Second vibration mode computed of the entire ultrasonic system. 9