GEMSTONE DEDICATED GAMMA IRRADIATOR DEVELOPMENT

Similar documents
Development of an irradiation system for a small size continuous run multipurpose gamma irradiator*

INVESTIGATIONS OF THE FRICKE GEL (FXG) DOSIMETER DEVELOPED AT IPEN IRRADIATED WITH 60 Co GAMMA RAYS

MECHANICAL AND THERMAL PROPERTIES OF COMMERCIAL MULTILAYER PET/PP FILM IRRADIATED WITH ELECTRON-BEAM

PERFLUORINATED POLYMER GRAFTING: INFLUENCE OF PRE- IRRADIATION CONDITIONS

PRELIMINARY CONCEPT OF A ZERO POWER NUCLEAR REACTOR CORE

STUDY OF ELECTRON BEAM IRRADIATION EFFECTS ON MORPHOLOGIC PROPERTIES OF THE PET/PP/PE/EVA POLYMERIC BLEND

BLOOD BIOCHEMISTRY EVALUATION IN HORSES HYPERIMMUNE SERA PRODUCTION

TECHNIQUE OF MEASURING THE FIRST IONIZATION COEFFICIENT IN GASES

THERMOLUMINESCENCE PROPERTIES OF OLIVINE

DIFFERENCES IN TRACE ELEMENT CONCENTRATIONS IN WHOLE BLOOD OF SMALL SIZED ANIMALS USING ANAA

GAMMA RADIATION MEASUREMENTS IN SELECT SAND SAMPLES FROM CAMBURI BEACH-VITÓRIA, ESPÍRITO SANTO, BRAZIL: PRELIMINARY RESULTS

EVALUATION OF Ra, Th, K AND RADIUM EQUIVALENT ACTIVITY IN SAND SAMPLES FROM CAMBURI BEACH, VITÓRIA, ESPÍRITO SANTO, BRAZIL.

Reactor Physics Calculations for a Sub critical Core of the IPEN-MB-01 driven by an external neutron source

MAXIMIZING SIGNAL-TO-NOISE RATIO (SNR) IN 3-D LARGE BANDGAP SEMICONDUCTOR PIXELATED DETECTORS IN OPTIMUM AND NON-OPTIMAL FILTERING CONDITIONS

TA3 Dosimetry and Instrumentation EVALUATION OF UNCERTAINTIES IN THE CALIBRATION OF RADIATION SURVEY METER POTIENS, MPA 1, SANTOS, GP 1

THERMAL HYDRAULIC MODELING OF THE LS-VHTR

FOOD IRRADIATION TECHNOLOGY. BAEN-625- Advances in Food Engineering

Method to evaluate the L/D Ratio of Neutron Imaging Beams

Irradiation by Ionizing Radiation Comparison of Ebeam, Xray with Gamma

CRITICAL LOADING CONFIGURATIONS OF THE IPEN/MB-01 REACTOR WITH UO 2 GD 2 O 3 BURNABLE POISON RODS

STUDY ON TRACE ELEMENT DETERMINATION IN HUMAN HEAD HAIR USING NEUTRON ACTIVATION ANALYSIS

ASSESSMENT OF A HEAT EXCHANGER INLET NOZZLE FLOW USING ANSYS-CFX

Chemical Etching Studies of a Brazilian Polycarbonate to Fast Neutron Detection

Treatment of effluents from petroleum production by electron beam irradiation

ALTERNATIVE METHODS FOR RADIOCHEMICAL PURITY TESTING IN RADIOPHARMACEUTICALS

DEVELOPMENT OF A SYSTEM USING THE LIBRARY OF THE GENIE SPECTROSCOPY SOFTWARE AND EXCHANGE OF SAMPLES

CHARACTERIZATION OF A RADIATION DETECTOR FOR AIRCRAFT MEASUREMENTS

)251(87521$&7,9$7,21$1$/<6,686,1*7+(23(16285&( &21&(37

The Radiation Effect of 60 Co Gamma Rays on Polycarbonate detector.

POLAROGRAPHIC DETERMINATION OF Sn (II) AND TOTAL Sn IN PYRO AND MDP RADIOPHARMACEUTICAL KITS

Drug delivery glucantime in PVP/chitosan membranes

GUAMA RIVER AND GUAJARA BAY, BELEM - AMAZON REGION

APPLICATION OF ADVANCED OXIDATIVE PROCESS IN TREATMENT RADIOACTIVE WASTE

Tritium concentration analysis of groundwater samples from the environmental monitoring program at IPEN, São Paulo, Brazil

Alpha spectrometry enriched uranium urinalysis results from IPEN

Calibration of a pencil ionization chamber with and without preamplifier

Preliminary Evaluation of Radiation Total Ionization Dose Influence on the Optical Transmittance of CBERS 3&4 Multispectral Camera (MUX) Subsystem

NATURAL RADIOACTIVITY ANALYSIS IN COMMERCIAL MARBLE SAMPLES OF SOUTHEAST REGION IN ESPÍRITO SANTO STATE: PRELIMINARY RESULTS

VERIFICATION AND VALIDATION OF ONE DIMENSIONAL MODELS USED IN SUBCOOLED FLOW BOILING ANALYSIS

6. Radioactive Sources and IAEA Course Catalog

Industrial and Commercial Applications of FRM II

Utilization of Egyptian Research Reactor and modes of collaboration

MATHEMATICAL MODEL OF RADON ACTIVITY MEASUREMENTS

Electron Beam Application for Regeneration of Catalysts Used in Refinery Cracking Units

WM 07 Conference, February 25 March 01, 2007, Tucson, AZ

N5 Physics. Key Definitions. Name:

SCINTILLATION RESPONSE OF CsI:Tl CRYSTAL UNDER NEUTRON, GAMMA, ALPHA PARTICLES AND BETA EXCITATIONS

THERMAL STRATIFICATION MONITORING OF ANGRA 2 STEAM GENERATOR MAIN FEEDWATER NOZZLES

Reliability and Traceability in Radiation Calibration

TECHNICAL WORKING GROUP ITWG GUIDELINE ON IN-FIELD APPLICATIONS OF HIGH- RESOLUTION GAMMA SPECTROMETRY FOR ANALYSIS OF SPECIAL NUCLEAR MATERIAL

Addressing challenges posed by electron beam irradiation through innovation Dr Yuwei Zhang Wuxi El Pont Radiation Technology

THE PBIL ALGORITHM APPLIED TO A NUCLEAR REACTOR DESIGN OPTIMIZATION

ESTABLISHING A PROTOCOL FOR ELEMENT DETERMINATIONS IN HUMAN NAIL CLIPPINGS BY NEUTRON ACTIVATION ANALYSIS. Thalita Pinheiro Sanches and Mitiko Saiki

PREPARATION AND QUALITY CONTROL OF 99m Tc-MDP

Chapter 21. Preview. Lesson Starter Objectives Mass Defect and Nuclear Stability Nucleons and Nuclear Stability Nuclear Reactions

EXPERIMENTAL DETERMINATION OF NEUTRONIC PARAMETERS IN THE IPR-R1 TRIGA REACTOR CORE

NEUTRON TRANSMUTATION DOPING OF SILICON: HIGHLY HOMOGENEOUS RESISTIVITY SEMICONDUCTOR MATERIAL PRODUCED IN NUCLEAR REACTORS. Artur Wilson Carbonari

COMPARISON OF CHROMATOGRAPHY SYSTEMS FOR RADIOCHEMICAL PURITY DETERMINATION OF LYOPHILIZED REAGENTS LABELED WITH TECHNETIUM-99m

THE USE OF IONISING RADIATION IN THE MANUFACTURE OF MEDICINAL PRODUCTS

PRESSURE DROP OF FLOW THROUGH PERFORATED PLATES

Simultaneous Removal of Various Pesticides from Contaminated HDPE Packaging by Radiation Processing: Electron Beam and Gamma Radiation Comparison

ANALYSIS OF THE MICROCLIMATE OF SÃO CRISTÓVÃO AND ITS INFLUENCE IN HEATING SYSTEMS, VENTILATING AND AIR CONDITIONING (HVAC)

Decontamination of pesticide packing using ionizing radiation

Comparison for Air Kerma from Radiation Protection Gamma-ray Beams with Brazilian Network /2017

Fact Sheet United States Nuclear Regulatory Commission Office of Public Affairs Washington, D.C Telephone: 301/

The Cobalt-60 Container Scanner

Principles of Solar Thermal Conversion

D-D FUSION NEUTRONS FROM A STRONG SPHERICAL SHOCK WAVE FOCUSED ON A DEUTERIUM BUBBLE IN WATER. Dr. Michel Laberge General Fusion Inc.

ACTIVATION ANALYSIS OF DECOMISSIONING OPERATIONS FOR RESEARCH REACTORS

COMPARISON OF ABSORBED DOSE TO AIR CALIBRATION FACTORS FOR A PARALLEL PLATE IONIZATION CHAMBER*

Energy: Conservation and Transfer

FLUORINE IN WATER AND TEETH MEASURED WITH PIGE

ACIDIC AQUEOUS URANIUM ELECTRODEPOSITION FOR TARGET FABRICATION

Measuring the Solar Constant

Laird Thermal Systems Application Note. Precise Temperature Control for Medical Analytical, Diagnostic and Instrumentation Equipment

Monte Carlo Simulations for a Preliminary Design of TRIGA IPR-R1 PGAA Facility

Applications for Industry and Environment. Radioisotope and Radiation Technology. International Atomic Energy Agency

FOUR-POINT CONTACT SLEWING RINGS - without gear [ O ]

Implementing the ISO Reference Radiations at a Brazilian Calibration Laboratory

Júlio Takehiro Marumo. Nuclear and Energy Research Institute, IPEN CNEN/SP, Brazil

WM2013 Conference, February 24 28, 2013, Phoenix, Arizona, USA

CALIBRATION OF IONIZATION CHAMBERS FOR COMPUTED TOMOGRAPHY BEAMS IN BRAZIL: THE PRESENT REALITY*

GRADE 8 SCIENCE. Course Overview

Planning a 100 percent renewable electricity system

Design Considerations for a Variable Angle Absolute Reflectance Accessory For the LAMBDA 950/850/650 UV/Vis/NIR and UV/Vis Spectrophotometers

Application of linear systems Linear Algebra with Computer Science Application

Activities at the Calliope facility at ENEA - Casaccia

2012 Annual Examinations. Subject: Physics Time: 2 Hours. Teacher s Name: Mr GJ Zahra, Mr M Mallia No. of Pages: 11. Name & surname: Class: Year 9.

CAPACITANCE SENSOR FOR VOID FRACTION MEASUREMENT IN A NATURAL CIRCULATION REFRIGERATION CIRCUIT

The photoneutron yield predictions by PICA and comparison with the measurements

State Atomic Energy Corporation Rosatom Russian Radiation Technologies: opportunities to success

Spent fuel inventory calculations in the SPIRE project: Current limits and expected improvements

DETERMINATION OF THE SERVICE LIFE FOR THE EXCORE NEUTRON DETECTOR CABLES IN SEABROOK STATION

Chapter 13: universal gravitation

Radioactive Waste Management

Appendices 193 APPENDIX B SCATTERING EXPERIMENTS

Uncertainty Measurement Evaluation of WDXRF and EDXRF Techniques for the Si and U total Determination in U 3 Si 2 used as Nuclear Fuel Material

International Atomic Energy Agency. Department of Nuclear Sciences and Applications. IAEA Environment Laboratories

LRO Lunar Reconnaissance Orbiter

MECHANICAL ENGINEERING. Five-year M.Sc. studies School of Mechanical Engineering National Technical University of Athens

Transcription:

2007 International Nuclear Atlantic Conference - INAC 2007 Santos, SP, Brazil, September 30 to October 5, 2007 ASSOCIAÇÃO BRASILEIRA DE ENERGIA NUCLEAR - ABEN ISBN: 978-85-99141-02-1 GEMSTONE DEDICATED GAMMA IRRADIATOR DEVELOPMENT Nelson M. Omi, Paulo R. Rela Instituto de Pesquisas Energéticas e Nucleares (IPEN / CNEN - SP) Av. Professor Lineu Prestes 2242 05508-000 São Paulo, SP nminoru@ipen.br prela@ipen.br ABSTRACT The gemstones gamma irradiation process to enhance the color is widely accepted for the jewelry industry. These gems are processed in conventional industrial gamma irradiation plant which are optimized for other purposes, using underwater irradiation devices with high rejection rate due to it's poor dose uniformity. A new conception design, which states the working principles and manufacturing ways of the device, was developed in this work. The suggested device's design is based on the rotation of cylindrical baskets and their translation in circular paths inside and outside a cylindrical source rack as a planetary system. The device is meant to perform the irradiation in the bottom of the source storage pool, where the sources remain always shielded by the water layer. The irradiator matches the Category III IAEA classification. To verify the physical viability of the basic principle, tests with rotating cylindrical baskets were performed in the Multipurpose Irradiator constructed in the CTR, IPEN. Also, simulations using the CADGAMMA software, adapted to simulate underwater irradiations, were performed. With the definitive optimized irradiator, the irradiation quality will be enhanced with better dose control and the production costs will be significantly lower than market prices due to the intended treatment device's optimization. This work presents some optimization parameters and the expected performance of the irradiator. 1. INTRODUCTION The gemstones gamma irradiation process to enhance the optical properties, like the color behavior, is widely accepted in jewelry industry. These gems are processed in conventional industrial gamma irradiation plants, which are optimized to irradiate products in atmospheric environment and stepped linear movement in front of the source rack. The gemstone irradiation use to be made in underwater environment in the bottom of the source storage pool, using narrow box shaped baskets. The product is placed in front of the source rack, with no movement during the irradiation process. The poor results of dose uniformity lead to the need of high overdoses in a substantial part of the product to achieve the proposed modification in most of the irradiated gemstones. Depending on the gemstone characteristics, the resulting rejection rate can be too high. A new conception design, which states the working principles and geometrical parameters of the device, was developed. The gemstone cylindrical basket planetary movement inside and outside a cylindrical source rack allows a better dose distribution control enhancing the dose uniformity rate (DUR), or the relation between the maximum and the minimum dose rate enhancing inside the irradiation container. The planetary system was optimized and its expected performance is presented in this work.

2. IRRADIATION DEVICE OPTIMIZATION The optimizations were based on the best throughput, with a maximum dose uniformity rate of 2.5. The operational safety, as long as the baskets were to be handled by the operators, and the device s simplicity, were considered, too. 2.1. Basket Length The dose distribution in a rotating cylindrical basket is radial, with the axial variation depending of the source length and the basket length relation and the distance between their axes. This behavior results in ring shaped isodose curves [1], with the higher doses located in external rings. Being vertically centered, the axial dose distribution depends mainly on the source length and the basket length relation. The best uniformity in this direction is achieved when the source is slightly higher than the product, since it is intended to have no vertical displacement during the irradiation process. Adapting the CADGAMMA application [2] to simulate underwater irradiation, the optimized basket length was determined to be 390 mm. 2.2. Source Rack, Basket and Translation Orbit Diameters The irradiator is intended to operate with multiple industrial sources, with a maximum 60 Co activity of 37 PBq (1,000 kci). The real operational load is intended to be 20 to 40% of this limit and it is planned to use sources ranging from 37 TBq (1 kci) to 50PBq (13.5 kci). Considering that, a single source rack with 150 source enclosure space will be enough. This observations lead to a designed rack with 740 mm diameter, considering the center of the sources. Using the CADGAMMA and limiting the dose uniformity rate to 2.5, 210 mm basket diameter was observed as the maximum diameter to be set up in the irradiation device. Due to ergonomic reason to handle baskets loaded with gemstones, the weight of each basket should not exceed 25 kg. The basket filled with gemstones will have, in air, an apparent density of 1.6 g/cm 3. A ten liter basket (190 mm diameter) weights 16 kg and the greatest diameter basket (190 mm) will weight 19.5 kg. The Table 1 shows the possible diameter and number of the baskets, with internal and external translation orbits. The operational safety led to the choice of the 210 mm internal baskets and 190 mm external baskets. This will ensure gaps enough to avoid operators hand catch. This choice makes easier to control baskets rotation, tying three external baskets to each internal one.

The Fig. 1 shows the irradiation device, side view cut, and the Fig. 2 shows the basket distribution in the orbital arrange. Storage pool Liner Lifting cables Main Axe Main Body Chain disk Ratchet Basket Axe Main Disk W6304 W6304 W6203 W6203 W6210 Basket Source rack base Figure 1: Irradiation device Internal basket disk External basket disk Chain tightener 72 Chain Main disk Figure 2: Orbital arrange

Table 1: Diameter and number of internal and external orbit baskets Orbit Internal External Basket Diameter Quantity Orbit Diameter Gap Between Baskets Device Circumference Diameter* 190 6 430 25.0-200 5 420 46.9-210 5 410 31.0-190 15 1050 28.3 1240 200 15 1060 20.4 1260 210 14 1070 28.0 1280 * Internal baskets do not influence in the device circumference diameter. Simulating external 190 mm diameter baskets and internal 210 mm diameter baskets in their orbits and the average dose during irradiation processes, the minimum dose rate (close to the basket axe) resulted to be statistically equal. The average distance of each source and the basket is larger for external baskets than internal ones and it compensates the larger layer to irradiate the center of the basket, the minimum dose rate point, in the 210 mm diameter device. The IPEN s compact size multipurpose industrial irradiator [3] source rack was used to perform basic tests to determine the dose rate in the gemstones, in underwater slow spinning basket. These tests, made with 190 mm and 210 mm diameter baskets, showed that using 7.4 PBq of 60Co load, in the proposed device, more than 54,000 kg per year of gemstones can be irradiated to a minimum dose of 600 kgy in one year [1]. 3. EXPECTED ECONOMICAL PERFORMANCE The irradiator plant implementation costs, including the irradiation device, source storage pool, water cooler, water deionizer and radioprotection tools is estimated to be about US$ 150,000.00, without the sealed sources. The 7.4 PBq (200 kci) of 60 Co sources load costs US$ 400,000.00. The system can be loaded with up to 37 PBq (1.000 kci) of 60 Co. The performance data was made with 7.4 PBq (200 kci), considering it as initial load. The amount of 600 kgy, required to treat many gemstones in the existing industrial irradiators, is adopted as a reference dose in this work. With the better dose control and uniformity, less than 600 kgy of minimum dose will be required, and using the commercial value of US$ 10.00 per kg of irradiated gemstones, the annual income of US$ 540,000.00 may be exceeded. To maintain this production, the operational cost, using the method presented by Morrison [4], is about US$ 171,250.00, where US$ 50,000.00 is for source replacement and

US$ 121,250.00 for other expenses, resulting in a US$ 3.17/kg of treated gemstone. Doubling the 60 Co load, the annual throughput may double, with the source replacement doubled in the overall costs and almost no increase in the other expenses. The demand for gemstone irradiation is limited and higher initial load at the beginning of the irradiator s operation may be too risky. But as the irradiation process becomes cheaper and the irradiation quality is enhanced, more gemstone producers can adopt this technique and new kinds of gemstone irradiation may become to be technically or economically available, enlarging the gemstone irradiation service market. 4. CONCLUSIONS The irradiator with 7.4 PBq (200 kci) of 60 Co sources can treat more than 54,000 kg per year of gemstones which absorbing 600 kgy as a reference dose. Many gemstones need less than this dose to get the desired change, increasing the annual throughput. With a capital investment of US$ 550,000.00, the annual liquid income may be beyond US$ 350,000.00, with 7.4 PBq load. The gemstone irradiation market may grow with lower irradiation prices and better color enhancement results. REFERENCES 1. N. M. Omi, M. H. O. Sampa, M. M. Hamada, P. R. Rela, Industrial Scale Gamma Irradiator for Gemstone Processing, Presented at IMRP 2006, Kuala Lumpur, February- 26 to March-03, (2006) 2. N. M. Omi, Geração de um Aplicativo Para Simulação de Doses em Sistemas de Irradiação Gama, M.Sc. thesis, Ipen-Cnen/SP, University of São Paulo, SP, Br, (2000) 3. W. A. P. Calvo, P. R. Rela, F. E. Sprenger, F. E. COSTA, N. M. OMI, L. G. A. SILVA, A small size continuous run industrial gamma irradiator, Radiation Physics and Chemistry, Volume 71, Issue 1-2, p. 563-565, (2004). 4. R. M. MORRISON, An economic Analysis of Electron Accelerators and Cobalt-60 for Irradiating Food - Technical Bullein no. 1762, United States Department of Agriculture, (June 1989)