AppNote 12/2012. Comparison of EG-Silicone-SBSE and Derivatization-PDMS-SBSE for the Analysis of Phenolic Compounds and Off-fl avors in Water KEYWORDS

Similar documents
AppNote 6/2004. Thermal Desorption GC Analysis of High Boiling, High Molecular Weight Hydrocarbons SUMMARY

AppNote 8/2008. A New Purge Tool for Use with Automated Headspace Analysis KEYWORDS ABSTRACT

AppNote 5/2008. Automation of Sample Preparation Steps using a Robotic X-Y-Z Coordinate Autosampler with Software Control KEYWORDS ABSTRACT

AppNote 2/2012. Determining Phenolic Compounds in Whisky using Direct Large Volume Injection and Stir Bar Sorptive Extraction KEYWORDS ABSTRACT

AppNote 14/2012. Thermal Gravimetric Analysis/Mass Spectrometry Simulation using the GERSTEL Automated Pyrolyzer KEYWORDS ABSTRACT

AppNote 7/2003. Coupling Retention Time Locked Methods and Libraries to Automated SPME or SBSE for Analysis of Flavors and Fragrances KEYWORDS

AppNote 4/2008. Automated Dynamic Headspace Sampling of Aqueous Samples Using Replaceable Adsorbent Traps KEYWORDS ABSTRACT

AppNote 2/2000. Stir Bar Sorptive Extraction (SBSE) applied to En vi ron men tal Aqueous Samples INTRODUCTION

TechNote 5/2002 KEYWORDS ABSTRACT. SBSE, Twister, Thermal Desorption

AppNote 15/2012. Large Volume Injection with Solvent Venting - Application to Trace Detection of Analytes in Water INTRODUCTION

AppNote 3/2014. Analysis of Aroma Compounds in Edible Oils by Direct Thermal Desorption GC/MS using Slitted Microvials KEYWORDS ABSTRACT

AppNote 1/2004. Use of a Mass Spectral Based Chemical Sensor to Discriminate Food and Beverage Samples: Olive Oils and Wine as Examples KEYWORDS

AppNote 10/2012. Large Volume Injection with GC/MS Multi Column Switching for Direct Determination of Ethyl Carbamate in Alcoholic Beverages KEYWORDS

AppNote 4/1998. New Developments in Multi-Dimensional Capillary Gas Chromatography KEYWORDS ABSTRACT

AppNote 1/2011 KEYWORDS ABSTRACT

AppNote 2/1996. Andreas Hoffmann Gerstel GmbH & Co.KG, Eberhard-Gerstel-Platz 1, D Mülheim an der Ruhr, Germany

AppNote 2/2001. Stir Bar Sorptive Extraction: Enhancing Selectivity of the PDMS Phase KEYWORDS ABSTRACT

AppNote 1/2007. Automated Dynamic Headspace Sampling using Replaceable Sorbent Traps KEYWORDS ABSTRACT

Off-gassing of Rubber Particles Used for Athletic Fields using Automated Dynamic Headspace Sampling

AppNote 6/2010. part a. Alternative Procedure for Extraction and Analysis of PAHs in Seafood by QuEChERS-SBSE-GC-MS KEYWORDS ABSTRACT

AromaOffi ce: Application of a Novel Linear Retention Indices Database to a Complex Hop Essential Oil

AppNote 2/2002. Discrimination of Soft Drinks using a Chemical Sensor and Principal Component Analysis KEYWORDS ABSTRACT

AppNote 3/2007 KEYWORDS INTRODUCTION. Beverage, Detector, Headspace, Quality Control

AppNote 7/2014. Automating Liquid-Liquid Extractions using a Bench-top Workstation KEYWORDS ABSTRACT. Sample Preparation, Lab Automation, LC/MS/MS

AppNote 8/2009. Fragrance Profi ling of Consumer Products using a Fully Automated Dynamic Headspace System KEYWORDS ABSTRACT

Analysis of Food Samples using Thin Film Solid Phase Microextraction (TF-SPME) and Thermal Desorption GC/MS

AppNote 5/2002. Characterization of a Mass Spectrometer based Electronic Nose for Routine Quality Control Measurements of Flavors KEYWORDS ABSTRACT

AppNote 8/2002 KEYWORDS ABSTRACT. Electronic Nose, Fast GC, Headspace Analysis, Chemometrics,

Thermal Desorption Unit TDU

AppNote 6/2014. Automated Online Desorption and Analysis of DNPH Derivatives of Airborne Aldehydes and Ketones KEYWORDS ABSTRACT

AppNote 3/2012. Rapid Automated Screening of Extractable Compounds in Materials for Food Packaging, Medical or Technical Purposes KEYWORDS ABSTRACT

AppNote 8/2012. Rapid Automated Extraction and Confi rmation of Buprenorphine and Norbuprenorphine in Urine by DPX-LC/MS/MS KEYWORDS ABSTRACT

AppNote 12/2008 KEYWORDS ABSTRACT

AppNote 2/2004. Analysis of Packaging Materials using a Mass Spectral Based Chemical Sensor KEYWORDS ABSTRACT

AppNote 8/2000. Volatile Organic Compounds from Adhesives and their Contribution to Indoor Air Problems KEY WORDS ABSTRACT

Screening of Pesticide Residues in Water by Sequential Stir Bar Sorptive Extraction-Thermal Desorption with GC/MS

AppNote 6/2012. Flavor and Fragrance Analysis of Consumer Products - Dynamic Headspace Compared to Some Traditional Analysis Approaches KEYWORDS

AppNote 2/2007. Automated Solid Phase Microextraction using the GERSTEL MPS Prepstation and MAESTRO Software KEYWORDS ABSTRACT

AppNote 1/2013. Determination of Barbiturates and 11-Nor-9-carboxy- 9 -THC in Urine using Automated Disposable Pipette Extraction (DPX) and LC/MS/MS

AppNote 2/2013. A High Throughput Automated Sample Preparation and Analysis Workfl ow for Comprehensive Toxicology Urine Screenings using LC/MS/MS

AppNote 4/2005. A Selectable Single or Multidimensional. Fraction Collection and Dual Detection for Trace Analysis of Complex Samples KEYWORDS

AppNote 8/2011 KEYWORDS ABSTRACT INTRODUCTION

AppNote 5/2001. The Analysis of the Bitter and Other Flavour Compounds in Beer and Wort by Stir Bar Sorptive Extraction (SBSE) Followed by HPLC

Determination of Off-Odor Compounds in Drinking Water Using an SPME Device with Gas Chromatography and Mass Spectrometry

AppNote 2/2000. Stir Bar Sorptive Extraction (SBSE) applied to Environmental Aqueous Samples

AppNote 9/2012. Solid Phase Micro-Extraction (SPME) Coupled with Selectable 1 D/ 2 D GC-MS for the Determination of Food Product Flavors KEYWORDS

GC/MS Application Note

AppNote 7/2003. Coupling Retention Time Locked Methods and Libraries to Automated SPME or SBSE for Analysis of Flavors and Fragrances

AppNote 7/2002. Classifi cation of Food and Flavor Samples using a Chemical Sensor KEYWORDS ABSTRACT

A New Way to Extract Off-Flavor Compounds in the Aquatic Environment. Stir Bar Sorptive Extraction (SBSE)

ENVIRONMENTAL analysis

AppNote 11/2012. Fully Automated Analysis of Doping Substances in Equine Urine by Disposable Pipette Extraction (DPX) coupled to GC/QqQ-MS KEYWORDS

anthracene Figure 1: Structures of Selected Polyaromatic Hydrocarbons (PAHs)

1,2-Dibromoethane (EDB) and 1,2-dibromo-3-chloropropane (DBCP), gas chromatography, microextraction

AppNote 2/1998. Direct Injection of Distilled Spirits with PTV Matrix Removal: The Perfect Splitless Injection? KEYWORDS INTRODUCTION

GERSTEL MultiPurpose Sampler MPS. Versatile autosampler and sample preparation robot

AppNote 6/2010. part b. High Throughput Method for the Determination of PAHs in Seafood by QuEChERS-SBSE-GC-MS SCOPE PRINCIPLE

Determination of Formaldehyde and VOCs in Wood-based Products using an Automated Micro-Scale Chamber

AppNote 7/2013. Comprehensive Automation of the SPE- GC/MS Analysis of Opioids, Cocaine and Metabolites from Serum and Other Matrices KEYWORDS

KEYWORDS ABSTRACT AppNote 6/2002

Sensitive Detection of 2-MIB and Geosmin in Drinking Water

AppNote 7/2005. Detection of Packaging Emissions using a Flexible Headspace Sampler Combined with a Multi Sensor System and a Separation Unit KEYWORDS

Application. Gas Chromatography February Introduction

AppNote 3/2011. Using Three Types of Twister Phases for Stir Bar Sorptive Extraction of Whisky, Wine and Fruit Juice KEYWORDS ABSTRACT

STANDARD OPERATING PROCEDURES SOP: 1826 PAGE: 1 of 18 REV: 0.0 DATE: 03/30/95 ANALYSIS OF METHYL PARATHION IN WIPE SAMPLES BY GC/MS

STANDARD OPERATING PROCEDURES

Uncontrolled Copy. SOP 109 Ethylene Glycol Screen by Gas Chromatography/Mass Spectrometry. Table of Contents. 1. Principle of Assay...

Selective Sample Enrichment of Gaseous Samples using a Cooled Injection System: Trace Determination of Sulphur Components in Natural Gas

METHOD 3510B SEPARATORY FUNNEL LIQUID-LIQUID EXTRACTION

AppNote 3/1998 KEYWORDS ABSTRACT. Beverage, Food & Flavor, PTV, Large Volume Injection, Headspace, Thermal Desorption.

Automated Sample Preparation of Headspace Standards Using the Agilent 7696 WorkBench

STANDARD OPERATING PROCEDURES SOP: 1828 PAGE: 1 of 14 REV: 0.0 DATE: 05/12/95 ANALYSIS OF METHYL PARATHION IN CARPET SAMPLES BY GC/MS

Analysis of Geosmin and 2-Methylisoborneol Utilizing the Stratum PTC and Aquatek 70

Determination of Volatile Aromatic Compounds in Soil by Manual SPME and Agilent 5975T LTM GC/MSD

AppNote 8/2001 KEYWORDS ABSTRACT. PAH, SPME, SBSE, GERSTEL Twister, Thermal desorption, GC-MS, PCB

METHOD 3520B CONTINUOUS LIQUID-LIQUID EXTRACTION

Analysis of BTEX in Natural Water with SPME

SPME-GC-MS/MS for Identification and Quantification of Migration Contaminants in Paperboard Food Packaging

AppNote 2/2015 KEYWORDS ABSTRACT

Trace analysis of mesityl oxide and diacetone alcohol in pharmaceuticals by capillary gas chromatography with flame ionization detection

METHOD 8030A ACROLEIN AND ACRYLONITRILE BY GAS CHROMATOGRAPHY

Rapid, Robust, and Sensitive Detection of 11-nor-D 9 - Tetrahydrocannabinol-9-Carboxylic Acid in Hair

AppNote 2/1996. Andreas Hoffmann Gerstel GmbH & Co.KG, Aktienstrasse , D Mülheim an der Ruhr, Germany

Sulfotepp impurities in Chlorpyrifos EC formulations

Application Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors

Determination of Pesticides in Aqueous Samples by On-Line Coupling Solid-Phase Extraction to Gas Chromatography with At-Column Concentrating Interface

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

Determination of underivatized aflatoxins B2, B1, G2, and G1 in ground hazelnuts by immunoaffinity solid-phase extraction with HPLC-FLD detection

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

Application. Gas Chromatography March 1998

METHOD 8041 PHENOLS BY GAS CHROMATOGRAPHY

AppNote 2/1999. Automated Sample Fractionation and Analysis Using a Modular LC-GC System

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

METHOD 3520C CONTINUOUS LIQUID-LIQUID EXTRACTION

OPTIMISATION OF SOLID PHASE MICROEXTRACTION (SPME) CONDITIONS FOR HEADSPACE ANALYSIS OF ORGANOPHOSPHATE PESTICIDES IN WHOLE BLOOD

Yokogawa Analytical Systems Inc., Nakacho, Musashino-shi, Tokyo , Japan.

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

A Comparative Analysis of Fuel Oxygenates in Soil by Dynamic and Static Headspace Utilizing the HT3 TM Automatic Headspace Analyzer

DISCLAIMER: This method:

Journal of Chromatography A, 1114 (2006)

Transcription:

AppNote 12/2012 Comparison of EG-Silicone-SBSE and Derivatization-PDMS-SBSE for the Analysis of Phenolic Compounds and Off-fl avors in Water Yunyun Nie, Thomas Albinus Gerstel GmbH & Co. KG, Eberhard-Gerstel-Platz 1, D-45473 Mülheim an der Ruhr, Germany KEYWORDS SBSE, TDU, Capillary GC/MS, Phenols, Off-flavor, Water ABSTRACT 16 phenolic compounds along with typical drinking water off-flavor compounds like geosmin, 2-methylisoborneol (MIB), and 2,4,6-trichloroanisole (TCA) were determined using two different approaches: 1) In-situ derivatization with acetic anhydride followed by SBSE using the PDMS Twister and Thermal Desorption (TD)-GCMS; 2) Direct SBSE without derivatization using the EG-Silicone Twister and subsequent TD-GCMS. In the case of the EG-Silicone twister, derivatization is not required due to its higher affinity for polar compounds. Both methods were evaluated for the extraction of 0.01 to 1 μg/l of phenols from water samples. Good linearity (> 0.996 for EG-Silicone Twister and > 0.993 for PDMS Twister with derivatization) and repeatability (0.7-11.8 % RSD for EG-Silicone Twisters and 1.0-13.6 % RSD for PDMS Twisters) were achieved for both methods. Limits of detection (LODs) were in the range 0.007-0.036 μg/l for the EG-Silicone Twister and 0.011-0.053 μg/l for the PDMS Twister respectively. The recoveries obtained with EG-Silicone Twisters were between 17 % (2-methylphenol) and 127 % (2,3,5-trichlorophenol). Both Twister types were successfully applied for the analysis of phenolic compounds in tap water samples.

INTRODUCTION The presence of phenolic compounds in the aquatic environment is the result of their industrial application for plastics, dyes, drugs, pesticides, antioxidants, paper and in petrochemical products. Phenols are an important raw material and additive for many industrial purposes. Chlorophenols are present in drinking-water as a result of chlorination of phenols during disinfection, as by-products of the reaction of hypochlorite with phenolic acids, as biocides, or as degradation products of phenoxy herbicides [1]. Within the huge group of phenolic compounds, several compounds are important water pollutants due to their character as endocrine disrupters and possible carcinogens. At levels of only a few ppb, phenols can affect the taste and odor of water and fish. The United States Environmental Protection Agency (EPA) lists eleven common phenols including 2,4,6- trichlorophenol, 2-chlorophenol, 2,4-dichlorophenol, 2,4-dimethylphenol and Pentachlorophenol as priority pollutants [2]. In European, the European Union (EU) has classified several phenols as priority contaminants in water. The European Community s drinking water framework directive 80/778/EC regulates a maximum admissible total concentration of 0.5 μg/l and maximum individual concentration of 0.1 μg/l for phenols in drinking water. In the 2011 German Federal Law Gazette for surface and costal waters, maximum concentration limits for 11 phenols are also given [3]. To reach the quantification limits required for the determination of phenols in drinking water, a concentration step is necessary. Liquid/liquid extraction (LLE), solid phase extraction (SPE), solid phase microextraction (SPME) and stir bar sorptive extraction (SBSE) are commonly used extraction- and concentration techniques [4-9]. LLE is prescribed in standard official methods for determination of phenols in water. US EPA Method 604 stipulates that one to two liters of water must be extracted with an appropriate amount of methylene chloride. The methylene chloride extract is then concentrated by evaporation to a volume of 10 ml or less and the solvent exchanged with 2- propanol followed by derivatization and GC/MS determination. In comparison with LLE, SPE requires much less solvent when different sorbents are used for the extraction. Only a small amount of solvent is then used to elute the extracted analytes, but drying, (evaporative) concentration and derivatization must still be performed before GC/MS determination. SPME and SBSE, in contrast, are solvent free techniques. Compared with LLE and SPE, only a small water sample is needed for analysis. Depending on the sorbent materials used, the extraction can be performed with or without derivatization. EXPERIMENTAL Standards and water samples. EPA 8040 phenol calibration mix (500 μg/ml each in isopropanol), 2-isopropyl-3-methoxypyrazine (100 μg/ml in methanol), 2-isobutyl-3-methoxypyrazine (100 μg/ml in methanol), 2,4,6-tribromophenol (1 g), 2,4-dibromophenol (1 g), 2,4,6-trichloroanisole (1 g), geosmin and 2-methylisoborneol (100 μg/ml in methanol) were purchased from Sigma-Aldrich. All standards were diluted to a stock concentration of 100 μg/l in methanol and used to spike 10 ml water samples to the required calibration levels. Methanol of analysis grade and HPLC water were obtained from Merck. Acetic acid anhydride, potassium carbonate and hydrochloric acid of analysis grade were obtained from Sigma-Aldrich. The stock solution and standard solutions were all stored in a refrigerator at 4 C. Calibration solutions were prepared with HPLC water with 5 % (v/v) methanol added to prevent a possible glass wall adsorption effect of the analytes. For EG-Silicone Twister extraction, the ph value was adjusted to ph=4 with hydrochloric acid to ensure that phenolic compounds were present in their nondissociated form. Tap water samples were obtained from Wakefield, England and Mülheim an der Ruhr, Germany. Sample Preparation - Extraction with PDMS Twisters. Before extraction with PDMS Twisters, the phenols were acetylated by adding acetic anhydride and potassium carbonate to the samples [9]. Derivatization was necessary in order to increase SBSE analyte recovery with the PDMS Twister and to provide better peak shapes on non-polar GC columns. To prepare the calibration solutions, a mixture of LC grade water with 5 % methanol was spiked with standard solutions to the required concentrations ranging from 0.01 to 1.0 μg/l. The water samples were also modified with 5 % (v/v) methanol to prevent analyte adsorption on the sample vial walls. One gram of potassium carbonate was placed into each 20 ml vial and conditioned at 110 C for 15 minutes. Then a 10 ml aliquot of the water sample was pipetted into a 20 ml AN/2012/12-2

vial and 0.5 ml acetic acid anhydride (Sigma-Aldrich) was added. A vial screw cap was loosely placed onto the vial to contain sample spray resulting from the CO 2 formation while still enabling the release of excess pressure. The vials were shaken for 10 minutes. The PDMS Twister was then placed into the sample and the vial was cap was firmly closed. For each of the seven calibration levels, five replicate extractions were performed using 10 mm GERSTEL Twisters (24 μl PDMS phase volume). SBSE was performed at room temperature for two hours, stirring at 1200 rpm on a multiple position magnetic stirplate. Following the extraction step, the Twisters were removed from the samples using a magnetic rod and then dried with a lint-free tissue and placed in individually sealed glass liners in the autosampler tray for analysis. Sample Preparation - Extraction with EG-Silicone Twisters. Due to the ethylene glycol composition of the EG-Silicone phase, no derivatization is needed when it is used for extraction of phenolic compounds. 10 ml aliquots of sample were pipetted into 10 ml vials. Before extraction, the ph value was adjusted to ph=4 in order to prevent dissociation of the phenols. EG-Silicone Twisters were then placed in the samples and the vials sealed with screw caps. The extraction conditions were similar to those used with PDMS Twisters: 2 hours at room temperature while stirring at 800 rpm. For each of the seven calibration levels, five replicate extractions were performed. Instrumentation. The TD-GC/MS analysis was performed using a Thermal Desorption Unit (TDU) combined with a MultiPurpose Sampler (MPS) equipped with a 10 μl syringe and a Cooled Injection System (CIS 4) programmed temperature vaporization (PTV) type inlet (all from GERSTEL). A 7890A gas chromatograph with a 5795 mass selective detector (MSD) was used (both from Agilent Technologies). The entire analysis system was operated under GERSTEL MAESTRO software control integrated with ChemStation software (Agilent Technologies) using one integrated method and one integrated sequence table. Analysis conditions PDMS Twister. TDU: Temperature 40 C (0.2 min); 720 C/min; 270 C (5min) Pneumatics 40 ml/min solvent vent (0.5 min) splitless CIS 4: Temperature -100 C (0.2 min); 12 C/s; 250 C (8 min) Pneumatics Liner GC: Oven Column Pneumatics MSD solvent vent, splitless (2 min) glass wool deactivated, d i = 2 mm 50 C (2 min); 5 C/min; 115 C (5 min); 25 C/min; 320 C (4 min) 30 m Rxi-5ms (Restek) d i = 0.25 mm d f = 0.25 μm He, constant flow = 1 ml/min SIM mode Analysis conditions EG-Silicone Twister TDU: Temperature 40 C (0.2 min); 720 C/min; 220 C (5min) Pneumatics 40 ml/min solvent vent (0.5 min) splitless CIS 4: Temperature -100 C (0.2 min); 12 C/s; 250 C (8 min) Pneumatics Liner GC: Oven Column Pneumatics MSD solvent vent, splitless (2 min) glass wool deactivated, d i = 2 mm 40 C (2 min); 20 C/min; 100 C; 3 C/min; 238 C; 15 C/min; 250 C (3 min) 30 m Stabilwax-DA (Restek) d i = 0.25 mm d f = 0.25 μm He, constant flow = 1 ml/min SIM mode AN/2012/12-3

RESULTS AND DISCUSSION PDMS Twister.The low polarity of the acetylated phenols enabled separation on an Rxi-5ms (Restek) column. Figure 1 shows an overlay of SIM traces at 7 calibration levels (0.01-1 μg/l). 1 4 24 3 16 17 21 22 23 26 2 5 6,7 8,9 10 11,12 13 14 15 18 20 19 25 Figure 1. Selected ion monitoring (SIM) chromatograms obtained from 7 calibration levels after extraction with PDMS Twisters. Column: Rxi-5ms (30 m x 0.25 μm x 0.25 mm), splitless. Table 1. List of target compounds identified in the SIM chromatograms resulting from PDMS Twister extractions. No. Compound No. Compound No. Compound 1 Phenol 10 2,4-Dimethylphenol 19 2,3,5-Trichlorophenol 2 2-Isopropyl-3-methoxypyrazine 11 2,6-Dichlorophenol 20 2,4-Dibromophenol 3 2-Methylphenol 12 2,4,6-Trichloroanisole (TCA) 21 2,3,6-Trichlorophenol 4 3-Methylphenol 13 4-Chloro-3-methylphenol 22 3,4,5-Trichlorophenol 5 4-Methylphenol 14 2,4-Dichlorophenol 23 2,3,5,6-Tetrachlorophenol 6 2-Methylisoborneol (MIB) 15 Geosmin 24 2,3,4,6-Tetrachlorophenol 7 2-Isobutyl-3-methoxypyrazine 16 2,4,6-Trichlorophenol 25 2,3,4,5-Tetrachlorophenol 8 2-Chlorophenol-3,4,5,6-d4 (ISTD) 17 2,3,4-Trichlorophenol 26 2,4,6-Tribromophenol 9 2-Chlorophenol 18 2,4,5-Trichlorophenol AN/2012/12-4

The instrument blank chromatogram (figure 2) and the Twister blank chromatogram show no peaks that interfere with the peaks of interest. However, the reagent blank chromatogram (including blank sample, potassium carbonate, acetic anhydride and the PDMS Twister) shows signals for phenol and methylphenols. Due to this reagent background, the calibration curves for these compounds (highlighted in table 1) were not satisfactory in terms of the linearity achieved and they were not determined in this study. Unfortunately, the instrumentation was not available to continue and pursue clarification of the matter with a different reagent. The time required for the derivatization is approximately 30 minutes (baking out potassium carbonate, adding sample & reagent, shaking), but multiple samples can be handled simultaneously, enabling the preparation of a large number of samples in approximately the same amount of time. First desorption: Level 4 = 0.1 µg/l Second desorption: Twister blank Instrument blank Figure 2. Selected ion monitoring (SIM) traces obtained from PDMS Twister extraction of derivatized phenols: First desorption after extraction of a 0.1 μg/l spiked water sample (blue trace); Second desorption of the same Twister showing the blank chromatogram (red trace); The instrument blank chromatogram without Twister (green trace). Column: Rxi-5ms (30 m x 0.25 μm x 0.25 mm), splitless analyte transfer. AN/2011/03-5

EG-Silicone Twister. In order to obtain good separation and good peak shape for underivatized phenols, a wax column (Stabilwax-DA, Restek) was used. The instrument parameters were the same as those used for the PDMS Twister apart from the GC oven program and the analyte ion masses monitored. The different TDU final desorption temperatures of 270 C and 220 C reflect the lower maximum desorption temperature of EG Silicone Twisters. Figure 3 shows the SIM chromatograms obtained from seven calibration levels. The identified analytes are listed in table 2. 5 1 2 3 4 6,7 (ISTD) 1013 8 9 11,12 14 15 16 20 17 21 19 18 22 23 25 24 Figure 3. Selected ion monitoring (SIM) chromatograms obtained at 7 calibration levels based on extractions with EG-Silicone Twister. Column: Stabilwax-DA (30 m x 0.25 μm x 0.25 mm), Restek, splitless. Table 2. List of target compounds identified in the SIM chromatogram based on extraction with EG-Silicone Twister. No. Compound No. Compound No. Compound 1 2-Isopropyl-3-methoxypyrazine 10 2,4-Dimethylphenol 19 4-Chloro-3-methylphenol 2 2-Isobutyl-3-methoxypyrazine 11 4-Methylphenol 20 3,4,5-Trichlorophenol 3 2-Methylisoborneol (MIB) 12 3-Methylphenol 21 2,4,5-Trichlorophenol 4 2,4,6-Trichloroanisole (TCA) 13 2,6-Dichlorophenol 22 2,3,5,6-Tetrachlorophenol 5 Geosmin 14 2,4-Dichlorophenol 23 2,3,4,6-Tetrachlorophenol 6 2-Chlorophenol 15 2,4,6-Trichlorophenol 24 2,4,6-Tribromophenol 7 2-Chlorophenol-3,4,5,6-d4 (ISTD) 16 2,3,6-Trichlorophenol 25 2,3,4,5-Tetrachlorophenol 8 2-Methylphenol 17 2,3,5-Trichlorophenol 9 Phenol 18 2,4-Dibromophenol Phenol is highlighted in the table because insufficient linearity was achieved due to an enhanced background value for phenol. The instrument used for this work is often used for customer samples and was available only for a short period of time, so this matter could unfortunately not be pursued further. Presumably, it would have been a matter of cleaning the inlet system properly. In a previously reported work (GERSTEL AppNote 2/2012) excellent linearity and very low background were demonstrated for both phenol and cresols using a similar system with an FFAP column. 3- and 4-methylphenol are equally greyed out in the table because they co-elute (peak no. 11 and 12 in the chromatogram). Since they both have the same mass-to-charge ratio, it is difficult to determine them individually. As a result, these three compounds were not evaluated further. AN/2011/03-6

The carryover and blank values were also tested. In figure 4, it can be seen that the chromatogram shows little carryover effect after the second desorption with the same EG-Silicone twister except for peak 9 (phenol) as explained earlier. The instrument blank afterwards shows the same peak for phenol. No phenol peak was found in the Twister blank chromatogram obtained directly after conditioning. 5 2 6,7 (ISTD) 13 First desorption: Level 4 = 0.1 µg/l 1 3 4 14 10 9 11,12 8 15 16 17 18 19 20 21 22 23 25 24 Second desorption: Twister blank Instrument blank Figure 4. Selected ion monitoring (SIM) chromatograms resulting from EG-Silicone Twister extractions: First desorption after extraction of a water sample spiked at 0.1 μg/l (blue); Second desorption using the same Twister for the Twister blank chromatogram (red); The instrument blank chromatogram without Twister (green). Stabilwax-DA (30 m x 0.25 μm x 0.25 mm), splitless. SBSE Recovery of phenolic compounds when using the EG-Silicone Twister. In order to determine the SBSE extraction efficiency for each compound, splitless liquid injections into the CIS were performed for comparison. A 6-point calibration for the liquid injection method was performed covering the concentration range from 0.05 ng/μl to 5 ng/μl in acetone. Each concentration level was analyzed in triplicate. The injection volume used was 1 μl. The squared correlation coefficients (R²) were found to be in excess of 0.999, which shows excellent linearity. The amount of extracted analytes was calculated using the linear equation obtained from liquid calibration curves. Recovery was calculated by dividing extracted amount of each compound with the total amount spiked into the water sample. Average recoveries were obtained at the seven Twister calibration levels (0.01-0.75 μg/l). At each concentration level, five replicate measurements were done. The relative standard deviations (RSDs) were found to be between 1 % and 8 % (table 3). Average recoveries ranged from 17 % (2-methylphenol) to 127 % (2, 3, 5-tricholorophenol). AN/2011/03-7

Table 3. Average recoveries (%) of phenolic and off flavor compounds determined at seven concentration levels listed with the associated relative standard deviations (% RSD) achieved using EG-Silicone Twister (n=5). Compounds are listed according to their log K o/w value. Compound Average Rec (%) RSD (%) Log K o/w * Compound Average Rec (%) 2-Methylphenol 17 8.1 2.06 2,4,6-Trichlorophenol 115 4.3 3.45 2-Chlorophenol 26 5.9 2.16 2,3,6-Trichlorophenol 123 3.4 3.45 2-Isopropyl-3-2,3,5-Trichlorophenol 127 4.2 3.45 27 4.8 2.37 methoxypyrazine 3,4,5-Trichlorophenol 104 1.3 3.45 2,4-Dimethylphenol 30 6 2.61 2,4,5-Trichlorophenol 123 1.7 3.45 4-Chloro-3-methylphenol 53 2.9 2.7 Geosmin 81 1.9 3.57 2,6-Dichlorophenol 56 3.6 2.8 2,4,6-Trichloroanisole 73 3.5 4.01 2,4-dichlorophenol 74 1.8 2.8 2,3,5,6-Tetrachlorophenol 115 6.1 4.09 2-Isobutyl-3-28 6.4 2.86 2,3,4,6-Tetrachlorophenol 112 5.4 4.09 methoxypyrazine 2,3,4,5-Tetrachlorophenol 111 2 4.09 2,4-Dibromophenol 96 2.3 3.29 2,4,6-Tribromophenol 103 5.7 4.18 2-Methylisoborneol 34 4.1 3.31 * Log K o/w : Logarithm of octanol-water partitioning coefficient obtained from the Estimation Programs Interface (EPI) Suite. It can be seen in figure 5 that with the exception of the five off flavor compounds 2-isopropyl-3-methoxypyrazine, 2-isobutyl-3-methoxypyrazine, 2-methylisoborneol, geosmin and 2,4,6-trichloroanisole, average recoveries increase with increasing log K o/w value. For the series 2-chlorophenol, dichlorophenols, trichlorophenols and tetrachlorophenols, solubility in water decreases with increasing number of halogens in the molecule. RSD (%) Log K o/w * Figure 5. Average recoveries of phenolic and malodor compounds obtained from seven calibration levels extracted with EG-Silicone Twister. Compounds are listed with increasing K o/w value from left to right. AN/2012/12-8

Linearity, Limits of Detection and Limits of Quantifi cation for both methods. Limits of detection (LODs) and limits of quantification (LOQs) of all compounds achieved with both Twisters were calculated according to DIN 32 645 based on the calibration curve [10]. LODs were calculated according to Eq. (1): (1) LOQs were calculated according to Eq. (2): (2) Here a k-factor value of 3 was used for all calculations, which means that 33.3 % is the maximum acceptable uncertainty. The summary of LODs and LOQs of selected compounds determined for the two types of Twister is listed in Table 4 along with the squared correlation coefficients (R²). Table 4. LODs and LOQs (μg/l) for phenolic and off flavor compounds and their linear squared correlation coefficients (R², N=5) achieved with derivatization-pdms-sbse and EG-Silicone-SBSE respectively. Compound LOD (µg/l) LOQ (µg/l) R² EG-Silicone PDMS EG-Silicone PDMS EG-Silicone PDMS 1 2-Isopropyl-3-methylpyrazine 0.024 0.039 0.08 0.12 0.999 0.997 2 2-Isobutyl-3-methylpyrazine 0.027 0.033 0.09 0.1 0.998 0.996 3 2-Methylisoborneol (MIB) 0.024 0.017 0.08 0.06 0.999 0.997 4 2,4,6-Trichloroanisole (TCA) 0.021 0.035 0.07 0.1 0.999 0.998 5 Geosmin 0.021 0.011 0.07 0.04 0.999 0.999 6 2-Chlorophenol 0.03 0.032 0.1 0.1 0.998 0.998 8 2-Methylphenol 0.022 n.a. 0.07 n.a. 0.999 n.a. 10 2,4-Dimethylphenol 0.027 0.053 0.09 0.16 0.998 0.996 13 2,6-Dichlorophenol 0.035 0.018 0.11 0.06 0.998 0.998 14 2,4-Dichlorophenol 0.035 0.025 0.11 0.07 0.998 0.997 15 2,4,6-Trichlorophenol 0.032 0.02 0.11 0.07 0.997 0.997 16 2,3,6-Trichlorophenol 0.036 0.029 0.12 0.09 0.997 0.997 17 2,3,5-Trichlorophenol 0.033 0.014 0.11 0.05 0.997 0.996 18 2,4-Dibromophenol 0.007 0.021 0.03 0.07 1 0.996 19 4-Chloro-3-methylphenol 0.024 0.016 0.08 0.05 0.999 0.998 20 3,4,5-Trichlorophenol 0.033 0.032 0.11 0.1 0.998 0.995 21 2,4,5-Trichlorophenol 0.03 0.054 0.1 0.14 0.997 0.994 22 2,3,5,6-Tetrachlorophenol 0.032 n.a. 0.1 n.a. 0.997 n.a. 23 2,3,4,6-Tetrachlorophenol 0.034 n.a. 0.11 n.a. 0.996 n.a. 24 2,4,6-Tribromophenol 0.03 0.015 0.1 0.05 0.998 0.995 25 2,3,4,5-Tetrachlorophenol 0.03 0.023 0.1 0.07 0.998 0.993 AN/2012/12-9

For the EG-Silicone Twister, LODs range from 0.007 μg/l (2,4-dimethylphenol) to 0.036 μg/l (2,3,6- trichlorophenol) and LOQs range from 0.03 μg/l to 0.12 μg/l. The squared correlation coefficients (R²) are larger than 0.996. For the PDMS Twister used in combination with derivatization, LODs range from 0.011 μg/l (geosmin) to 0.054 μg/l (2,4,5-trichlorophenol) and LOQs range from 0.04 μg/l to 0.14 μg/l with R² higher than 0.993. Both SBSE methods meet the requirements of EU water framework directive, which regulates that the concentration of individual phenols in drinking-water should not exceed 0.1 μg/l. Both the techniques described in this work achieve much lower LOQ values than the maximum concentration limits of 1-10 μg/l specified in the Germany federal law gazette for surface and coastal waters. Table 5 lists LODs reported in literature for the determination of phenols in water using different sample preconcentration methods in combination with different analytical techniques. By comparison, the SBSE-TD- GC-MS methods based on two different types of Twisters presented in this work achieve low limits of detection (LODs) and low relative standard deviation (RSD %) Table 5. Literature data for the determination of phenols in water [5]. Method LOD (µg/l) RSD (%) Derivatization reagent Real Sample LLE-GC-MS (EPA 625) 1,5-42 - Pentafl uorobenzyl bromide Municipal and industrial wastewater SPE-CE-DAD 28-399 6.7-12.3 - Wastewater SPE-HPLC-IFD 0.0012-66.58 Sodium 1- naphthalenesulfonate Wastewater SPME-GC-MS 0.052-9.1 3,3-20 - Groundwater and surface water SPME-HPLC-UVD 0.25-3.67 1.52-6.38 - River water and wastewater SBSE-TD-GC-MS 0.1-0.4 6-27 Acetic anhydride Groundwater and lake water PDMS Twister 0.011-0.054 1.0 13.6 Acetic anhydride Drinking water EG-Silicone Twister 0.007-0.036 0.7 11.8 - Drinking water Drinking Water. After method validation for derivatization-pdms-sbse and EG-Silicone-SBSE, two tap water samples from England (Wakefield) and Germany (Mülheim an der Ruhr) were analyzed using the EG-Silicone Twister method. The tap water samples were modified with 5 % Methanol and the ph value adjusted to ph=4. Each water sample was analyzed in triplicate and the average concentration calculated from the linear calibration curves. The SIM chromatograms of tap water from England and Germany are shown in figure 6. Only geosmin and 2-methylphenol could be quantified in the Wakefield tap water at concentrations of 0.030 μg/l and 0.028 μg/l respectively. None of the target compounds were found at levels above their respective LOQs in the Mülheim an der Ruhr tap water. Spiked water sample: 0.1 µg/l Tap water from Wakefield, England Tap water from Mülheim an der Ruhr, Germany Figure 6. SIM chromatograms obtained from a water sample spiked at 0.1 μg/l (black), tap water from Wakefield, England (blue) and tap water from Mülheim an der Ruhr, Germany (red) using EG-Silicone-SBSE. AN/2012/12-10

CONCLUSION SBSE-TD-GC/MS methods for the determination of phenols and off flavor compounds in water using two types of Twister were compared and validated. SBSE based on the PDMS Twister used in combination with derivatization and SBSE based on the EG-Silicone Twister used without derivatization both gave similar results: Low limits of detection and quantification, good linearity and repeatability, and negligible carryover. Based on the low limits of detection, simplicity of use, low cost and high quality of results, SBSE-TD-GC/ MS is a highly suitable tool for the determination of phenols and off flavor compounds in water. The use of a multi-position stir plate enables simultaneous extraction of many samples ensuring high throughput while reducing the amount of time needed for sample preparation. Acetylation derivatization combined with PDMS Twister extraction is a well-known and proven method for determination of phenols that enables the use of a standard DB-5 equivalent column for GC/MS, which means the system can easily be used for applications such as pesticide or VOC analysis. The effort required for the derivatization work is very limited. Deuterated internal standards were not used in this study, but might provide additional robustness for more dirty samples such as wastewater. The PDMS Twister s maximum desorption temperature of 300 C enables better and more complete conditioning, lower background and overall the PDMS Twister offers better long-term stability than the EG-Silicone Twister. EG-Silicone Twister allows direct extraction from water samples without a derivatization step, saving time and resources. Since non-derivatized analytes are extracted, the recovery is more easily determined using liquid injection of the standard solution as reference. In this work it was found that a 5 min. desorption at 220 C is sufficient for complete desorption of both phenols and the determined off flavors compounds. Table 6. Summary of the SBSE-TD-GC-MS methods used for phenols in water with each type of Twister used. PDMS Twister EG-Silicone Twister Sample Volume (ml) 10 10 Derivatization Reagent Acetic anhydride + Potassium carbonate - Extraction time (h) 2 2 Thermal Desorption 270 C, Splitless 220 C, Solvent Vent Column Rxi-5ms, 30 m x 0.25 mm x 0.25 µm Stabilwax-DA, 30 m x 0.25 mm x 0.25 µm LOD (µg/l) 0.011 0.053 0.007 0.035 LOQ (µg/l) 0.06 0.16 0.03 0.11 R² >0.993 > 0.996 RSD % 1.0 13.6 0.7 11.9 Recovery % - 17 127 ACKNOWLEDGEMENTS Enrique Longeira, Grupo Biomaster, Spain David Evans, Severn Trent Laboraties, UK Dan Carrier, Anatune, UK REFERENCES [1] Chlorophenols in Drinking-water, Guidelines for drinking-water quality, 2nd ed. Vol.2. Health criteria and other supporting information. World Health Organization, Geneva, 1996. [2] EPA Method 604, Phenols, Part VIII, 40 CFR Part 136, Environmental Protection Agency, Washington, DC, 26 October 1984, p.58. [3] Bundesgesetzblatt Jahrgang 2011, Teil I Nr.37. AN/2012/12-11 [4] I. Rodríguez, M.P. Llompart, R. Cela, J. Chromatogr. A 885 (2000) 291-304. [5] M. Saraji, M. Marzban, Anal Bioanal Chem (2010) 396: 2685-2693. [6] L. Montero, S. Conradi, H. Weiss, P. Popp, J. Chromatogr. A 1071 (2005) 163-169. [7] M. Llompart, M. Louride, P. Landín, C. García- Jares, R. Cela, J. Chromatogr. A 963 (2002) 137-148. [8] P. Barták, L. Cáp, J. Chromatogr, A 767 (1997) 171-175. [9] S. Nakamura, S. Daishima, J. Chromatogr, A 1038 (2004) 291-294. [10] W. Funk, V. Dammann, G. Donnevert. Quality assurance in analytical chemistry (2nd edition). Wiley-VCH, Weinheim, 2006.

GERSTEL GmbH & Co. KG Eberhard-Gerstel-Platz 1 45473 Mülheim an der Ruhr Germany +49 (0) 208-7 65 03-0 +49 (0) 208-7 65 03 33 gerstel@gerstel.com www.gerstel.com GERSTEL Worldwide GERSTEL, Inc. 701 Digital Drive, Suite J Linthicum, MD 21090 USA +1 (410) 247 5885 +1 (410) 247 5887 sales@gerstelus.com www.gerstelus.com GERSTEL AG Wassergrabe 27 CH-6210 Sursee Switzerland +41 (41) 9 21 97 23 gerstelag@ch.gerstel.com www.gerstel.ch GERSTEL K.K. 1-3-1 Nakane, Meguro-ku Tokyo 152-0031 SMBC Toritsudai Ekimae Bldg 4F Japan +81 3 5731 5321 +81 3 5731 5322 info@gerstel.co.jp www.gerstel.co.jp GERSTEL LLP Level 25, North Tower One Raffles Quay Singapore 048583 +65 6622 5486 +65 6622 5999 SEA@gerstel.com www.gerstel.com GERSTEL Brasil Av. Pascoal da Rocha Falcão, 367 04785-000 São Paulo - SP Brasil +55 (11)5665-8931 +55 (11)5666-9084 gerstel-brasil@gerstel.com www.gerstel.com.br Information, descriptions and specifications in this Publication are subject to change without notice. GERSTEL, GRAPHPACK and TWISTER are registered trademarks of GERSTEL GmbH & Co. KG. Copyright by GERSTEL GmbH & Co. KG Awarded for the active pursuit of environmental sustainability