Mercuric Thiocyanate Method Method to 25.0 mg/l Cl Reagent Solution

Similar documents
Chromium, Total. Alkaline Hypobromite Oxidation Method 1 Method to 0.70 mg/l Cr (spectrophotometers) 0.01 to 0.60 mg/l Cr (colorimeters)

Tetraphenylborate Method Method to 7.0 mg/l K Powder Pillows

Instrument Sample cell orientation Sample cell DR 6000 DR 3800 DR 2800 DR 2700 DR 5000 DR The fill line is to the right.

Chromotropic Acid Method Method to 30.0 mg/l NO 3 N (HR) Test N Tube Vials

Cadmium Reduction Method Method to 0.50 mg/l NO 3 N (LR) Powder Pillows

Powder Pillows 0.01 to 1.60 mg/l SiO 2 (LR, colorimeters)

Powder Pillows 0.01 to 0.80 mg/l Al 3+ (colorimeters)

Cadmium Reduction Method Method to 10.0 mg/l NO 3 N (MR, spectrophotometers) 0.2 to 5.0 mg/l NO 3 N (MR, colorimeters)

Chlorphosphonazo Colorimetric Method Method to 1000 µg/l Ca and Mg as CaCO 3 (ULR) Solution Pillow. Instrument Adapter Sample cell

Scope and application: For water, wastewater and seawater. Distillation is required for wastewater and seawater.

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

Instrument Sample cell orientation Sample cell DR 6000 DR 3800 DR 2800 DR 2700 DR 1900 DR 5000 DR The fill line is to the right.

Nitrogen, Total Inorganic

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856

Chloramine (Mono) and Nitrogen, Free Ammonia

Persulfate Digestion Method Method to 25.0 mg/l N (LR) Test N Tube Vials

Phosphorus, Total. USEPA 1 PhosVer 3 with Acid Persulfate Digestion Method Method to 3.50 mg/l PO. Test preparation

Persulfate Digestion Method Method to 150 mg/l N (HR) Test N Tube Vials

FerroZine Method 1 Method to 100 µg/l Fe (10-cm cell) Reagent Solution. Instrument Adapter Sample cell DR 6000 LZV

Colorimetric Method Method to 0.70 mg/l Ag Powder Pillows

Cadion Method Method to 0.30 mg/l Cd TNTplus 852

PAR Method Method to 2.0 mg/l Pb TNTplus 850

Instrument Sample cell orientation Sample cell DR 6000 DR 3800 DR 2800 DR 2700 DR 1900 DR 5000 DR The fill line is to the right.

Chromazurol S Method Method to 0.50 mg/l Al TNTplus 848

Persulfate Digestion Method Method to 40 mg/l N (HR) TNTplus 827

Dimethylphenol Method Method to mg/l NO 3 N or 1.00 to mg/l NO

Oxygen Demand, Chemical

Peracetic Acid (PAA) and Hydrogen Peroxide (H 2 O 2 )

Phenolphthalein and Total Alkalinity Method to 4000 mg/l as CaCO 3 Digital Titrator

Oxygen Demand, Chemical

Cadmium Reduction Method Method 8171 MR (0.1 to 10.0 mg/l NO 3

Method to 0.50 mg/l NH 3 N Powder Pillows

Method to 0.50 mg/l NH 3 N Powder Pillows

Chlorine, Free and Total, High Range

Nitrogen, Ammonia. Test Preparation. Powder Pillows Method Method 8155 Salicylate Method 1 Powder Pillows

Scope and application: For wastewater, seawater, drinking water, surface water and process water.

Chlorine, Total. USEPA DPD Method 1 Method to mg/l as Cl 2 Chemkey Reagents. Test preparation. Before starting.

DR/4000 PROCEDURE. IRON, Total

Chlorine, Free and Total, High Range

Method 8326 (0.006 to mg/l Al 3+ ) Powder Pillows

DR/4000 PROCEDURE NITRATE. 2. The display will show:

Trihalomethane Formation Potential (THMFP)

Quaternary Ammonium Compounds

Sulfide DOC Methylene Blue Method 1 (0 0.70, and mg/l) Method Test procedure

Chlorine, Free and Total, Low Range

PAR Method Method to 2.0 mg/l Pb TNTplus 850

1,5-Diphenylcarbohydrazide Method* Powder Pillows or AccuVac Ampuls (0 to mg/l Cr 6+ )

DR/4000 PROCEDURE NITRATE. Using Powder Pillows

TPH (Total Petroleum Hydrocarbons)

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

DR/4000 QUATERNARY AMMONIUM COMPOUNDS PROCEDURE. 2. The display will show: 3. Fill a sample cell (the blank) with 25 ml of deionized water.

Salicylate Method Method HR (2 to 47 mg/l NH 3 N) TNTplus 832

Chloride, HR, Direct Measurement ISE Method Method g/l to 35 g/l Cl Powder Pillow ISA

CHLORINE, TOTAL (0 to 4.00 mg/l)

DR/4000 PROCEDURE. HARDNESS, Total

Polychlorinated Biphenyls (PCB) in Soil

DR/4000 PROCEDURE LEAD. 2. The display will show: 3. Fill a 250-mL graduated cylinder to the 250-mL mark with sample.

Mercaptoacetic Acid Method*

DR/4000 PROCEDURE SELENIUM. 4. Measure 100 ml of sample into a second 500-mL erlenmeyer flask (label the flask sample ).

NITRITE, Low Range (0 to mg/l NO 2- -N)

NITROGEN, AMMONIA, High Range, Test N Tube

Direct Measurement ISE Method Method to 4.00 mg/l NO 3 N TISAB Solution

Cadmium Reduction Method (Using Powder Pillows or AccuVac Ampuls)

Method (0.04 to 4.50 mg/l Cl 2 ) Powder Pillows

DR/4000 PROCEDURE CYANIDE. 1. Press the soft key under HACH PROGRAM. Select the stored program for cyanide by pressing 1750 with the numeric keys.

NITROGEN, TOTAL, HR, Test N Tube

SILICA, Low Range (0 to 1.60 mg/l)

DR/4000 PROCEDURE MERCURY. Phase 1: Sample Digestion must be done in a fume hood! Toxic gases may be produced.

NITROGEN, TOTAL, Test N Tube * Method 10071

DPD Test N Tube Method *

p-dimethylaminobenzaldehyde Method*

Hach Method Spectrophotometric Measurement of Free Chlorine (Cl 2 ) in Finished Drinking Water

CHLORINE, FREE, Ultra-high Range ( mg/l Cl 2 ) Method 10069

Manganese III Digestion Method * (with chloride removal)

Steam-Assisted Gravity Drainage Water Analysis Handbook

Steam-Assisted Gravity Drainage Water Analysis Handook

ALLOWAY METHOD OUTLINE

Sample Preparation LCW 909. Total Kjeldahl Nitrogen, TKN NB: NEW! LCW 909 GB

Hach Company TNTplus 835/836 Nitrate Method Spectrophotometric Measurement of Nitrate in Water and Wastewater

Z/zs. tnitiats: wu\ Z-z* I A. sop-c-102. Determination of Chemical Oxygen Demand. Revision 6. Approval: Effective date: 3. Renewat date: 7lt:,:

METHOD 7196A CHROMIUM, HEXAVALENT (COLORIMETRIC)

METHOD #: Approved for NPDES and SDWA (Ed. Rev. 1974, 1978) Fluoride, Total (Colorimetric, SPADNS with Bellack Distillation)

PRETREATMENT TECHNICAL DATA SHEET A CHROME-FREE FINAL RINSE PRODUCT DESCRIPTION

Experiment 18 - Absorption Spectroscopy and Beer s Law: Analysis of Cu 2+

Hach Method Total Organic Carbon in Finished Drinking Water by Catalyzed Ozone Hydroxyl Radical Oxidation Infrared Analysis

METHOD 9252A CHLORIDE (TITRIMETRIC, MERCURIC NITRATE)

Sodium Chloride - Analytical Standard

Titration with an Acid and a Base

SIDE BY SIDE COMPARISON TABLE FOR HACH METHOD NUMBER COLORIMETRIC DETERMINATION OF CYANIDE

Ammonia Gas Sensing Combination Electrode

Percentage of Acetic Acid in Vinegar

Schools Analyst Competition

ASTM Designation: D Standard Test Method for Determination of Iodine Number of Activated Carbon

Ammonia Gas Sensing Combination Electrode

EXPERIMENT 6. Properties of Buffers INTRODUCTION

Experimental Procedure Lab 402

ASCORBIC ACID METHOD FOR PHOSPHORUS DETERMINATION

METHOD 9200 NITRATE. 1.2 The applicable range of concentration is 0.1 to 2 mg NO -N per liter. 3 of sample.

Sample Preparation of Electronic Device Components for Hexavalent Chromium Analysis by IEC Method :2017

PRETREATMENT TECHNICAL DATA SHEET CHROMIUM-FREE ORGANIC PASSIVATING RINSE PRODUCT DESCRIPTION

Transcription:

Chloride DOC316.53.01017 Mercuric Thiocyanate Method Method 8113 0.1 to 25.0 mg/l Cl Reagent Solution Scope and application: For water and wastewater. Test preparation Instrument-specific information Table 1 shows all of the instruments that have the program for this test. The table also shows sample cell and orientation requirements for specific instruments. To use the table, select an instrument, then read across to find the applicable information for this test. Table 1 Instrument-specific information Instrument Sample cell orientation Sample cell DR 6000 DR 3800 DR 2800 DR 2700 DR 1900 DR 5000 DR 3900 The fill line is to the right. 2495402 The fill line is toward the user. Before starting Filter samples that are turbid with filter paper and a funnel. The reagents that are used in this test contain mercury. Collect the reacted samples for safe disposal. Review the Safety Data Sheets (MSDS/SDS) for the chemicals that are used. Use the recommended personal protective equipment. Dispose of reacted solutions according to local, state and federal regulations. Refer to the Safety Data Sheets for disposal information for unused reagents. Refer to the environmental, health and safety staff for your facility and/or local regulatory agencies for further disposal information. Items to collect Description Mercuric Thiocyanate Solution Ferric Ion Solution Deionized water Quantity 2 ml 1 ml 10 ml Pipet, TenSette, 0.1 1.0 ml 1 Pipet tips, for TenSette Pipet, 0.1 1.0 ml 2 Sample cells (For information about sample cells, adapters or light shields, refer to Instrumentspecific information on page 1.) 2 Refer to Consumables and replacement items on page 4 for order information. 1

Sample collection Test procedure Collect samples in clean glass or plastic bottles. If immediate analysis is not possible, keep the samples at room temperature for a maximum of 28 days. Start 1. Start program 70 Chloride. For information about sample cells, adapters or light shields, refer to Instrument-specific information on page 1. 2. Prepare the blank: Fill a sample cell with 10 ml of deionized water. 3. Prepare the sample: Fill a second sample cell with 10 ml of sample. 4. Use a pipet to add 0.8 ml of Mercuric Thiocyanate Solution into each sample cell. 5. Swirl to mix. 6. Use a pipet to add 0.4 ml of Ferric Ion Solution into each sample cell. 7. Swirl to mix. The sample shows an orange color if chloride is in the sample. 8. Start the instrument timer. A 2-minute reaction time starts. Zero 9. When the timer expires, clean the blank sample cell. Complete the remaining steps within 5 minutes. 10. Insert the blank into the cell holder. 11. Push ZERO. The display shows 0.0 mg/l Cl. 12. Clean the prepared sample cell. 2 Chloride, Mercuric Thiocyanate Method (25.0 mg/l)

Read 13. Within 5 minutes after the timer expires, insert the prepared sample into the cell holder. 14. Push READ. Results show in mg/l Cl. Interferences Table 2 Interfering substances Interfering substance Interference level Extreme ph The expected ph after the reagents are added is approximately 2. Accuracy check If the sample is strongly acidic or alkaline, adjust a portion of sample before testing to a ph of approximately 7. Use 5 N Sodium Hydroxide Standard Solution 1. Measure the ph with ph paper because most ph electrodes will contaminate the sample with chloride. Standard additions method (sample spike) Use the standard additions method (for applicable instruments) to validate the test procedure, reagents and instrument and to find if there is an interference in the sample. Items to collect: 1000-mg/L Chloride Standard Solution 50-mL cylinders, graduated mixing (3) Pipet, TenSette, 0.1 1.0 ml and tips 1. Use the test procedure to measure the concentration of the sample, then keep the (unspiked) sample in the instrument. 2. Go to the Standard Additions option in the instrument menu. 3. Select the values for standard concentration, sample volume and spike volumes. 4. Open the standard solution. 5. Prepare three spiked samples: use the TenSette pipet to add 0.1 ml, 0.2 ml and 0.3 ml of the standard solution, respectively, to three 50-mL portions of fresh sample. Mix well. 6. Use the test procedure to measure the concentration of each of the spiked samples. Start with the smallest sample spike. Measure each of the spiked samples in the instrument. 7. Select Graph to compare the expected results to the actual results. Note: If the actual results are significantly different from the expected results, make sure that the sample volumes and sample spikes are measured accurately. The sample volumes and sample spikes that are used should agree with the selections in the standard additions menu. If the results are not within acceptable limits, the sample may contain an interference. Standard solution method Use the standard solution method to validate the test procedure, the reagents and the instrument. 1 Refer to Optional reagents and apparatus on page 5. Chloride, Mercuric Thiocyanate Method (25.0 mg/l) 3

Items to collect: 1000-mg/L Chloride Standard Solution 500-mL volumetric flask, Class A 10.00-mL volumetric pipet, Class A and pipet filler safety bulb Deionized water 1. Prepare a 20.0-mg/L chloride standard solution as follows: a. Use a pipet to add 10.00 ml of a 1000-mg/L chloride standard solution into the volumetric flask. b. Dilute to the mark with deionized water. Mix well. Prepare this solution daily. 2. Use the test procedure to measure the concentration of the prepared standard solution. 3. Compare the expected result to the actual result. Note: The factory calibration can be adjusted slightly with the standard adjust option so that the instrument shows the expected value of the standard solution. The adjusted calibration is then used for all test results. This adjustment can increase the test accuracy when there are small variations in the reagents or instruments. Method performance The method performance data that follows was derived from laboratory tests that were measured on a spectrophotometer during ideal test conditions. Users can get different results under different test conditions. Program Standard Precision (95% confidence interval) Sensitivity Concentration change per 0.010 Abs change 70 20.0 mg/l Cl 17.9 22.1 mg/l Cl 0.1 at 1.0 mg/l, 0.3 at 10.0 mg/l, 0.6 at 20.0 mg/l Cl Summary of Method Chloride in the sample reacts with mercuric thiocyanate to form mercuric chloride and liberate thiocyanate ion. Thiocyanate ions react with the ferric ions to form an orange ferric thiocyanate complex. The amount of this complex is proportional to the chloride concentration. The measurement wavelength is 455 nm. Consumables and replacement items Required reagents Description Quantity/test Unit Item no. Chloride Reagent Set, includes: 250 tests/pkg 2 2319800 Ferric Ion Solution 1 ml 100 ml 2212242 Mercuric Thiocyanate Solution 2 ml 200 ml 2212129 Water, deionized varies 100 ml 27242 Required apparatus Description Quantity/test Unit Item no. Pipet, TenSette, 0.1 1.0 ml 1 each 1970001 Pipet tips, for TenSette Pipet, 0.1 1.0 ml 2 50/pkg 2185696 2 The number of tests refers to any combination of samples and reagent blanks. 4 Chloride, Mercuric Thiocyanate Method (25.0 mg/l)

Recommended standards Description Unit Item no. Chloride Standard Solution, 1000-mg/L Cl 500 ml 18349 Optional reagents and apparatus Description Unit Item no. Mixing cylinder, graduated, 50 ml each 2088641 Filter paper, folded, 3 5-micron, 12.5-cm 100/pkg 69257 Flask, volumetric, Class A, 500 ml, glass each 1457449 Funnel, poly, 75 mm each 108368 Paper, ph, 1.0 11.0 5 rolls/pkg 39133 Pipet, volumetric, Class A, 10 ml each 1451538 Pipet filler, safety bulb each 1465100 Safety goggles, vented each 2550700 Sodium Hydroxide Solution, 5 N 50 ml 245026 Chloride, Mercuric Thiocyanate Method (25.0 mg/l) 5

FOR TECHNICAL ASSISTANCE, PRICE INFORMATION AND ORDERING: In the U.S.A. Call toll-free 800-227-4224 Outside the U.S.A. Contact the HACH office or distributor serving you. On the Worldwide Web www.hach.com; E-mail techhelp@hach.com HACH COMPANY WORLD HEADQUARTERS Telephone: (970) 669-3050 FAX: (970) 669-2932 Hach Company/Hach Lange GmbH, 2007, 2010, 2012, 2014, 2018. All rights reserved. 02/2018, Edition 9