MSOP/QSOP/SOIC/TSSOP ICP Analysis Note

Similar documents
Test Report No. SH /CHEM Date: Oct. 22, 2009 Page 1 of 5

Test Report No: (1) R1 Date: 29-Apr-13 Page 1 of 5

No. : CE/2012/A3090 Date : 2012/10/23 GAP PAD 1000SF RICK STEWART REPORT PER REQUEST FOR QUOTE, DATED 10/5/11

Page 2 of 8 Test Result(s) PART NAME No.1 SILVER COLORED PASTE Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI) Sum of PBBs

Test Report No. : CE/2008/38467 Date : 2008/04/07 Page : 2 of 11 Test Result(s) PART NAME NO.1 : BLACK PLASTIC TUBE Cadmium (Cd) Lead (Pb) Mercury (Hg

Test Report No: (1) R1 Date: 29-Oct-10 Page 1 of 5

The following sample(s) was/were submitted and identified by/on behalf of the client as : (2) (3) (4) (5) Please refer to next page(s).

Test Report No. CANEC Date: 01 Sep 2011 Page 1 of 8

Test Report No. : KA/2010/C2116 Date : 2011/01/05 Page : 2 of 6 Test results by chemical method (Unit: mg/kg) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexa

Test Report No. : KA/2012/40043 Date : 2012/04/10 Page : 2 of 8 Test Result(s) PART NAME NO.1 : BLACK EPOXY MOLDING COMPOUNDS Test Item (s): MDL Resul

No. CE/2012/C1503 Date 2012/12/18 Page 2 of 6 Test Result(s) PART NAME No.1 Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr(VI

No. KE/2016/52417 Date 2016/05/26 Page 2 of 6 Test Result(s) PART NAME No.1 Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr(VI

No. CE/2014/51910 Date 2014/05/20 Page 2 of 5 Test Result(s) PART NAME No.1 Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI

TEST REPORT. : The following submitted sample(s) said to be:-

Test Report No. F690101/LF-CTSAYAA

Test Report No. : CE/2009/45866B Date : 2009/05/20 Page : 1 of 7

Test Report No. KE/2017/C1499 Date 2018/01/02 Page 2 of 7 Test Result(s) PART NAME No.1 WHITE POLYOXYMETHYLENE Test Item(s) Cadmium (Cd) Lead (Pb) Mer

Chemical Laboratory - Kao., Test Report No. : KE/2018/11379 Date : 2018/01/25 Page : 2 of 8 Test Result(s) PART NAME NO.1 : CLEAR FAL FILM WITH ADHESI

Test Report No. : KA/2012/61391 Date : 2012/06/28 Page : 2 of 9 Test Result(s) PART NAME NO.1 : BLACK EPOXY MOLDING COMPOUND Test Item (s): Unit Metho

Page 2 of 9 Test Result(s) PART NAME No.1 DARK BROWN PASTE Test Item(s) Cadmium (Cd) Lead (Pb) Unit Method With reference to IEC (2013) and pe

TEST REPORT Report No. : GR:HL: DATE : 20/11/2014

Management number No. KA/2015/80033 Date 2015/08/10 Page 1 of 6 The following sample(s) was/were submitted and identified by/on behalf

Test Report No. SH / CHEM Date: Apr. 28, 2008 Page 1 of 6

Test Report No. : CE/2015/15894 Date : 2015/02/04 NIHON ALMIT CO., LTD. ALMIT BLDG., , YAYOICHO, NAKANO-KU, TOKYO, JAPAN Page : 1 of 7 *CE/2015/

Test Report No. : KE/2016/B2076 Date : 2016/11/24 Page : 2 of 8 Test Result(s) PART NAME NO.1 : GRAY Test Item (s): Unit Method Cadmium (Cd) mg/kg Wit

TEST REPORT : SR A-DC, SR A-DA, SR A-DT, SR A-DN, SR C-DC, SR C-DA, SR C-DT, SR C-DN

Test Report No. KD/2013/50027A-01 Date 2013/07/01 Page 2 of 6 Test Result(s) PART NAME No.1 PART NAME No.2 PART NAME No.3 Cadmium (Cd) Lead (Pb) Mercu

No. CE/2012/44922 Date 2012/05/03 Page 2 of 9 Test Result(s) PART NAME No.1 DARK BROWN LUMP Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalen

Page 2 of 11 Test Result(s) PART NAME No.1 TRANSPARENT-YELLOW PASTE Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI) Sum of

Thin Film on Silicon Resistor Networks Models 2NBS, 2QSP Mold Material Change

Test Report No. : KA/2012/41514 Date : 2012/05/07 Page : 2 of 9 Test Result(s) PART NAME NO.1 : SILVER NIPPON COPPER WIRE Cadmium (Cd) mg/kg With refe

Chemical Laboratory - Kao., SGS Taiwan Ltd. Test Report No. : KE/2017/40842 Date : 2017/04/17 ROGERS CORPORATION 245 WOODSTOCK ROAD, WOODSTOCK, CT. 06

TEST REPORT. Page : 1 of 9 Report No. RT14R-U E Date: Oct. 13, : The following submitted sample(s) said to be:-

TEST REPORT Report No. : GR:HL: DATE : 27/10/2014

Page 2 of 12 Test Result(s) PART NAME No.1 IC TRANSCEIVER Test Item(s) Cadmium (Cd) Unit Method With reference to IEC (2013) and performed by

Page 2 of 10 Test Result(s) PART NAME No.1 TRANSPARENT-YELLOW PASTE Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI) Sum of

Technical Report No A Dated

SM8eu/SOT89eu ICP Analysis Note

Test Report No. CE/2016/43515 Date 2016/04/22 Page 2 of 7 Test Result(s) PART NAME No.1 AMBER FILM Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) He

TEST REPORT. : The following submitted sample(s) said to be:- SAMPLE RECEIVED : Jan. 07, 2019 TESTING DATE : Jan. 07, 2019 ~ Jan.

Page 2 of 12 Test Result(s) PART NAME No.1 YELLOW LUMP Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr(VI) Sum of PBBs Monobro

Test Report No. : CE/2014/B4428 Date : 2014/12/03 Page : 1 of 12 PELNOX CO., LTD. 8-7 BODAI, HADANO CITY, KANAGAWA , JAPAN *CE/2014/B4428* The

Test Report No. CE/2017/62572 Date 2017/06/19 Page 2 of 7 Test Result(s) PART NAME No.1 PINK SHEET Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) He

TEST REPORT. * Note 2 : This report shall not be reproduced except in full without the written approval of the testing laboratory.

3M OPTICAL SYSTEMS No. : CE/2007/13746 Page : 2 of 6 Test Result(s) PART NAME NO.1 : 3M OPTICAL FILM Test Item (s): Unit Method MDL Result Method No.1

Page 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr(VI) Sum of PBBs

Page 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Test Item(s) Cadmium (Cd) Unit Method With reference to IEC (2013) and performe

Page 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Cadmium (Cd) Lead (Pb) Test Item(s) Unit Method With reference to IEC (2013) an

Page 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Test Item(s) Cadmium (Cd) Unit Method With reference to IEC (2013) and performe

Test Report. Report No. RLSHD Page 1 of 6

Page 2 of 10 Test Result(s) PART NAME No.1 LT.GRAY SHEET Test Item(s) Cadmium (Cd) Lead (Pb) Unit Method With reference to IEC (2013) and perf

Test Report. Report No. RLSHE Page 2 of 5 Test Result: Content 1 2

Page 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr(VI) Sum of PBBs

Test Report MITSUI HIGH-TEC (SHANGHAI) CO.,LTD NO.2001 XINJIN QIAO ROAD EXPORT PROCESSING ZONE PUDONG SHANGHAI CHINA

Test Report No. CE/2014/43454A Date 2014/04/23 Page 2 of 11 Test Result(s) PART NAME No.1 MIXED ALL PARTS Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Ite

Test Report No. CE/2015/C2965A Date 2016/02/16 Page 2 of 7 Test Result(s) PART NAME No.1 MIXED ALL PARTS Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item

CHI NHANH CONG TY TNHH SAN XUAT THUONG MAI HA PHONG -XUONG SAN XUAT

Page 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI) ( ) Sum of

Test Report. Report No. ECL01H Page 1 of 9

Test Report. Report No. ECL01H Page 1 of 7

Test Report. Report No. SCL03H Page 1 of 7

Test Report No. : KA/2014/61579 Date : 2014/07/07 Page : 2 of 14 Test Result(s) PART NAME NO.1 : GOLD BONDING WIRE Test Item (s): Unit Method Cadmium

Chemical Laboratory - Kao., SGS Taiwan Ltd. Test Report No. : KA/2017/50850 Date : 2017/05/25 HERAEUS MATERIALS SINGAPORE PTE LTD BLOCK 5002, ANG MO K

TEST REPORT NUMBER: SHAH TESTS CONDUCTED. (A) TEST RESULT SUMMARY FOR RoHS DIRECTIVE:

Page 2 of 11 Test Result(s) PART NAME No.1 YELLOW/WHITE PAD (EXCLUDING THE RELEASE FILM) Cadmium (Cd) Lead (Pb) Test Item(s) Unit Method With referenc

Page 2 of 9 Test Result(s) PART NAME No.1 SILVER COLORED PASTE Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI) Sum of PBBs

Test Report No. : KA/2012/21431 Date : 2012/02/24 Page : 2 of 12 Test Result(s) PART NAME NO.1 : SILVER GRAY DIE ATTACH PASTE Test Item (s): Unit Meth

TEST REPORT. * Note 2 : This report shall not be reproduced except in full without the written approval of the testing laboratory.

Page 2 of 12 Test Result(s) PART NAME No.1 DK. BROWN LUMP Cadmium (Cd) Lead (Pb) Mercury (Hg) Antimony (Sb) Beryllium (Be) Test Item(s) Hexavalent Chr

Chemical Laboratory - Kao., Page 2 of 14 Test Result(s) PART NAME No.1 SILVER COLORED PASTE Cadmium (Cd) Test Item(s) Unit Method mg/kg With reference

Test Report. Report No. ECL01I Page 1 of 7

Test Report No. : CE/2014/50660 Date : 2014/05/22 Page : 2 of 14 Test Result(s) PART NAME No.1 Cadmium (Cd) Lead (Pb) Mercury (Hg) Antimony (Sb) Test

Test Report No. : CE/2009/34977 Date : 2009/03/25 Page : 1 of 10

ICP Test Report Certification Packet

Page 2 of 10 Test Result(s) PART NAME No.1 MIXED BLACK AND WHITE PASTE Test Item(s) Cadmium (Cd) Lead (Pb) Unit Method With reference to IEC (

Test Report. Report No. ECL01H Page 1 of 9

Test Report No. : CE/2014/32788 Date : 2014/03/27 Page : 2 of 14 Test Result(s) PART NAME No.1 : YELLOW SHEET Cadmium (Cd) Lead (Pb) Mercury (Hg) Test

Page : 2 of 12 Test Result(s) PART NAME No.1 : MIXED ALL PARTS Test Item(s) Cadmium (Cd) Unit Method With reference to IEC (2013) and performe

Chemical Laboratory - Kao., Page 2 of 14 Test Result(s) PART NAME No.1 BLACK EPOXY MOLDING COMPOUND Cadmium (Cd) Test Item(s) Unit Method mg/kg With r

Chemical Laboratory - Kao., Page 2 of 14 Test Result(s) PART NAME No.1 BLACK EPOXY MOLDING COMPOUND Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) H

Test Report No. : CE/2013/51536 Date : 2013/05/29 Page : 2 of 14 Test Result(s) PART NAME No.1 : YELLOW SHEET Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexa

Test Report No _rev01 Date: 06/DEC/2017 Page 1 of 5

TEST REPORT. Address : , Doksan-dong, Geumcheon-gu, Seoul, Korea Page: 1 of 12 Report No. RT16R-S E Date: Jul.

Test Report No Date : 14-Feb-2018 Page 1 of 10

TEST REPORT. : Lead Frame / Ag is plated on Ni-Fe Alloy-A42 material

Test Report No Date : 27/NOV/2017 Page 1 of 5

TEST REPORT. ADDRESS : 77, Seokam-ro 13-gil, Iksan, Jeonllabuk-do, Korea PAGE: 1 of 8 REPORT NO. RT17R-U2181-E DATE: Dec. 29, 2017

ICP Test Report Certification Packet

Test Report. Report No. ECL01H Page 1 of 7

Test Report NANTONG HUADA MICROELECTRONICS GROUP CO., LTD NO.99 ZILANG ROAD,NANTONG CITY,JIANGSU PROVINCE

Test Report KUO SEN ENTERPRISE CO.,LTD NO.87-2 NINGPAO WEST ST. TAIPEI, TAIWAN, R.O.C

Test Report No. CTSSA/13164/14 Date: 11/07/2014 Page: 1 of 10 CTS Ref. CTSSA/14/2009/Redring

Test Report No. CTSSA/ /12 Date : 10/01/2012 Page: 1 of 5 CTS Ref. CTSSA/12/0018/Straits

Test Report. Report No. RLSHE Page 2 of 7

Test Report No: (2) Date: 24-Jun-2014 Page 1 of 5

Page 2 of 11 Test Result(s) PART NAME No.1 COPPER/SILVER COLORED METAL SHEET (INCLUDING THE PLATING LAYER) Cadmium (Cd) Test Item(s) Unit Method With

Test Report No. CTSSA/27121/12 Date : 04/01/2013 Page: 1 of 5 CTS Ref. CTSSA/12/4387/Luvata

Chemical Laboratory - Kao., Page 2 of 13 Test Result(s) PART NAME No.1 BLACK EPOXY MOLDING COMPOUND Cadmium (Cd) Test Item(s) Unit Method mg/kg With r

Transcription:

Reference: ICP Analysis Note Date of Issue: 22 December 2008 MSOP/QSOP/SOIC/TSSOP ICP Analysis Note The appended ICP Analysis reports demonstrate compliance with EC directives 2002/95/EC (Restriction of the use of certain hazardous substances RoHS ) and the 24 th amendment to 76/769/EEC (Restrictions on the marketing and use of certain dangerous substances and preparations). This analysis was performed to independently verify that the content of lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls (PBB), and polybrominated diphenyl ethers (PDBE) present is within the permitted levels set. Note: This report is a composite of the reports for the individual, homogenous parts of the product. The table below is a summary of the data in the following pages. Zetex makes no warranty, representation or guarantee regarding the suitability of this information or other data provided by Zetex on environmentally hazardous substances, nor does Zetex assume any liability arising from the use of this information and specifically disclaims any and all consequential and incidental damages. K.Clithero Group Quality Manager RoHS Substance Result (ppm) Lead 19 Mercury Cadmium Hexavalent Chromium Polybrominated Biphenyls (PBB) Polybrominated Diphenyl Ethers (PDBE) Not detected Not detected Not detected Not detected Not detected This publication is issued to provide outline information only which (unless agreed by the Company in writing) may not be used, applied or reproduced for any purpose or form part of any order or contract or be regarded as a representation relating to the products or services concerned. The Company reserves the right to alter without notice the specification, design, price or conditions of supply of any product or service. Sales offices The Americas 3050 E. Hillcrest Drive Westlake Village, CA 91362-3154 Tel: (+1) 805 446 4800 Fax: (+1) 805 446 4850 Europe Kustermannpark Balanstraße 59, D-81541 München Germany Tel: (+49) 894 549 490 Fax: (+49) 894 549 4949 Taiwan 7F, No. 50, Min Chuan Road Hsin-Tien Taipei, Taiwan Tel: (+886) 289 146 000 Fax: (+886) 289 146 639 Shanghai Rm. 606, No.1158 Changning Road Shanghai, China Tel: (+86) 215 241 4882 Fax (+86) 215 241 4891 Shenzhen Room A1103-04, ANLIAN Plaza, #4018 Jintian Road Futian CBD, Shenzhen, China Tel: (+86) 755 882 849 88 Fax: (+86) 755 882 849 99 Diodes Zetex products are distributed worldwide. For details, see http://www.zetex.com & http://www.diodes.com Korea 6 Floor, Changhwa B/D, 1005-5 Yeongtong-dong, Yeongtong-gu, Suwon-si, Gyeonggi-do, Korea 443-813 Tel: (+82) 312 731 884 Fax: (+82) 312 731 885 2008 Diodes Zetex Semiconductors Limited

Signature Not Verified For Question, Please Contact with SGS www.tw.sgs.com Test Report No. : CE/2008/49068 Date : 2008/05/08 Page : 1 of 4 ZETEX SEMICONDUCTORS PLC ZETEX TECHNOLOGY PARK, CHADDERTON, OLDHAM. OL9 9LL. UNITED KINGDOM *CE/2008/49068* The following sample(s) was/were submitted and identified by/on behalf of the client as: Sample Description : Buyer/Order No. : Sample Receiving Date : Testing Period : WAFER 65637 2008/04/30 2008/04/30 TO 2008/05/08 =================================================================================== Test Result(s) : Please refer to next page(s). The content of this PDF file is in accordance with the original issued reports for reference only. This Test Report cannot be reproduced, except in full, without prior written permission of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this report is unlawful and offenders may be prosecuted to the fullest extent of the law. SGS TAIWAN LIMITED NO. 136-1, Wu Kung Road, WuKu Industrial Zone, Taipei county, Taiwan. t(886-2) 22993939 f(886-2) 2299-3237 www.sgs.com.tw

Test Report No. : CE/2008/49068 Date : 2008/05/08 Page : 2 of 4 ZETEX SEMICONDUCTORS PLC ZETEX TECHNOLOGY PARK, CHADDERTON, OLDHAM. OL9 9LL. UNITED KINGDOM Test Result(s) *CE/2008/49068* PART NAME NO.1 : WAFER Test Item(s): Unit Method MDL Result No.1 Cadmium (Cd) mg/kg With reference to IEC 2 n.d. 62321/2nd CDV (111/95/CDV). Determination of Cadmium by ICP-AES. Lead (Pb) mg/kg With reference to IEC 2 n.d. 62321/2nd CDV (111/95/CDV). Determination of Lead by ICP- AES. Mercury (Hg) mg/kg With reference to IEC 2 n.d. 62321/2nd CDV (111/95/CDV). Determination of Mercury by ICP-AES. Hexavalent Chromium Cr(VI) by mg/kg With reference to IEC 2 n.d. alkaline extraction 62321/2nd CDV (111/95/CDV). Determination of Hexavalent Chromium for non-metallic samples by UV/Vis Spectrometry. Antimony (Sb) mg/kg With reference to US EPA Method 3050B for Antimony Content. Analysis was performed by ICP-AES. 2 n.d. Halogen-Chlorine (Cl) (CAS No.: 007782-50-5) Halogen-Bromine (Br) (CAS No.: 007726-95-6) mg/kg mg/kg With reference to BS EN 14582:2007. Analysis was performed by IC method for Chlorine content. With reference to BS EN 14582:2007. Analysis was performed by IC method for Bromine content. 50 n.d. 50 n.d. The content of this PDF file is in accordance with the original issued reports for reference only. This Test Report cannot be reproduced, except in full, without prior written permission of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this report is unlawful and offenders may be prosecuted to the fullest extent of the law. SGS TAIWAN LIMITED NO. 136-1, Wu Kung Road, WuKu Industrial Zone, Taipei county, Taiwan. t(886-2) 22993939 f(886-2) 2299-3237 www.sgs.com.tw

Test Report No. : CE/2008/49068 Date : 2008/05/08 Page : 3 of 4 ZETEX SEMICONDUCTORS PLC ZETEX TECHNOLOGY PARK, CHADDERTON, OLDHAM. OL9 9LL. UNITED KINGDOM *CE/2008/49068* Test Item(s): Unit Method MDL Result No.1 SumofPBBs - n.d. Monobromobiphenyl 5 n.d. Dibromobiphenyl 5 n.d. Tribromobiphenyl 5 n.d. Tetrabromobiphenyl 5 n.d. Pentabromobiphenyl 5 n.d. Hexabromobiphenyl 5 n.d. Heptabromobiphenyl 5 n.d. Octabromobiphenyl 5 n.d. Nonabromobiphenyl 5 n.d. Decabromobiphenyl With reference to IEC 5 n.d. SumofPBDEs(MonotoNona) 62321/2nd CDV (111/95/CDV). - n.d. mg/kg (Note 4) Determination of PBB and Monobromodiphenyl ether PBDE by GC/MS. 5 n.d. Dibromodiphenyl ether 5 n.d. Tribromodiphenyl ether 5 n.d. Tetrabromodiphenyl ether 5 n.d. Pentabromodiphenyl ether 5 n.d. Hexabromodiphenyl ether 5 n.d. Heptabromodiphenyl ether 5 n.d. Octabromodiphenyl ether 5 n.d. Nonabromodiphenyl ether 5 n.d. Decabromodiphenyl ether 5 n.d. Sum of PBDEs(Mono to Deca) - n.d. Note 1. mg/kg = ppm 2. n.d. = 3. MDL = Method Detection Limit 4. According to 2005/717/EC DecaBDE is exempt. 5. " - " = Not Regulated The content of this PDF file is in accordance with the original issued reports for reference only. This Test Report cannot be reproduced, except in full, without prior written permission of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this report is unlawful and offenders may be prosecuted to the fullest extent of the law. SGS TAIWAN LIMITED NO. 136-1, Wu Kung Road, WuKu Industrial Zone, Taipei county, Taiwan. t(886-2) 22993939 f(886-2) 2299-3237 www.sgs.com.tw

Test Report No. : CE/2008/49068 Date : 2008/05/08 Page : 4 of 4 ZETEX SEMICONDUCTORS PLC ZETEX TECHNOLOGY PARK, CHADDERTON, OLDHAM. OL9 9LL. UNITED KINGDOM *CE/2008/49068* ** End of Report ** The content of this PDF file is in accordance with the original issued reports for reference only. This Test Report cannot be reproduced, except in full, without prior written permission of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this report is unlawful and offenders may be prosecuted to the fullest extent of the law. SGS TAIWAN LIMITED NO. 136-1, Wu Kung Road, WuKu Industrial Zone, Taipei county, Taiwan. t(886-2) 22993939 f(886-2) 2299-3237 www.sgs.com.tw

Signature Not Verified Digitally Signed by www.tw.sgs.com

Test Report No. SH8050865/CHEM Date: Apr. 16, 2008 Page 1 of 5 HERAEUS ZHAOYUAN PRECIOU METAL MATERIALS CO., LTD/ HERAEUS ZHAOYUAN (CHANGSHU) ELECTRONIC MATERIAL CO., LTD NO.238 LINGLONG ROAD, ZHAOYUAN SHANGDONG/ NO.248 HUANGHE ROAD CHANGSHU, JIANGSU The following sample(s) was/were submitted and identified by/on behalf of the client as: Sample Name : GOLD BONDING WIRE HD SGS Ref No. : 10960194 Main Substance : GOLD Sample Receiving Date : Apr.15, 2008 Testing Period : Apr.15 16, 2008 Test Requested Test Method Test Results Conclusion : In accordance with the RoHS Directive 2002/95/EC, and its amendment directives. : With reference to IEC 62321/2 nd CDV (111/95/CDV) Procedures for the Determination of Levels of Regulated Substances in Electrotechnical Products (1) Determination of Cadmium by ICP. (2) Determination of Lead by ICP (3) Determination of Mercury by ICP. (4) Determination of Hexavalent Chromium by Spot test / Colorimetric Method. (5) Determination of PBBs and PBDEs by GC/MS. : Please refer to next pages : Based on the performed tests on submitted samples, the results comply with the RoHS Directive 2002/95/EC and its subsequent amendments. Signed for and on behalf of SGS-CSTC Chemical Laboratory Signed for and on behalf of SGS-CSTC Chemical Laboratory Ella Zhang Section Manager Sandy Hao Lab Manager

Test Report No. SH8050865/CHEM Date: Apr. 16, 2008 Page 2 of 5 Test results by chemical method (Unit: mg/kg) Test Item(s): Method RoHS 1 MDL (refer to) Limit Cadmium(Cd) (1) ND 2 100 Lead (Pb) (2) ND 2 1000 Mercury (Hg) (3) ND 2 1000 Hexavalent Chromium (CrVI) See (4) Negative by spot test / boiling-water extraction Note (5) # Sum of PBBs ND - 1000 Monobromobiphenyl ND 5 - Dibromobiphenyl ND 5 - Tribromobiphenyl ND 5 - Tetrabromobiphenyl ND 5 - Pentabromobiphenyl ND 5 - Hexabromobiphenyl ND 5 - Heptabromobiphenyl ND 5 - Octabromobiphenyl ND 5 - Nonabromobiphenyl ND 5 - Decabromobiphenyl ND 5 - Sum of PBDEs (Note 4) (5) ND - 1000 Monobromodiphenyl ether ND 5 - Dibromodiphenyl ether ND 5 - Tribromodiphenyl ether ND 5 - Tetrabromodiphenyl ether ND 5 - Pentabromodiphenyl ether ND 5 - Hexabromodiphenyl ether ND 5 - Heptabromodiphenyl ether ND 5 - Octabromodiphenyl ether ND 5 - Nonabromodiphenyl ether ND 5 - Decabromodiphenyl ether ND 5 - Sum of PBDEs (Mono to Deca) ND - - Test Part Description: 1. Golden metal thread

Test Report No. SH8050865/CHEM Date: Apr. 16, 2008 Page 3 of 5 Note: (1) mg/kg = ppm (2) ND = (3) MDL = Method Detection Limit (4) Sum of Mono to NonaBDE & according to 2005/717/EC DecaBDE is exempt. (5) Spot-test: Negative = Absence of CrVI coating, Positive = Presence of CrVI coating; (The tested sample should be further verified by boiling-water-extraction method if the spot test result is Negative or cannot be confirmed.) Boiling-water-extraction: Negative = Absence of CrVI coating Positive = Presence of CrVI coating; the detected concentration in boiling-water-extraction solution is equal or greater than 0.02 mg/kg with 50 cm 2 sample surface area. (6) # = Positive indicates the presence of Hexavalent Chromium on the tested areas. Negative indicates the absence of CrVI on the tested areas. (7) - = Not Regulated (8) The maximum permissible limit is quoted from the document 2005/618/EC amending RoHS directive 2002/95/EC

Test Report No. SH8050865/CHEM Date: Apr. 16, 2008 Page 4 of 5 ATTACHMENTS 1) Name of the person who made measurement: Cathy Cai/George Xu/Diane Wang 2) Name of the person in charge of measurement: Terry Wang/Tracy Yue 3) These samples were dissolved totally by pre-conditioning method according to below flow chart. (Cr6+ and PBBs/PBDEs test method excluded) Sample Preparation Sample Measurement Pb/Cd/Hg PBBs/PBDEs Cr 6+ Acid digestion with microwave/ hotplate Sample solvent extraction Nonmetallic material Metallic material Filtration Concentration/ Dilution of extraction solution Adding extraction solution Positive Spot test Solution Residue Total digestion Filtration Heating to 90~95 for extraction Boiling water extraction Negative ICP-AES/AAS DATA GC/MS DATA Filtration and ph adjustment Adding 1,5- diphenylcarbazide for color development UV-Vis Adding 1,5- diphenylcarbazide for color development A red color indicates the presence of Cr6+. If necessary, confirm with UV-Vis. DATA DATA

Test Report No. SH8050865/CHEM Date: Apr. 16, 2008 Page 5 of 5 Sample photo: SH8050865/CHEM SGS authenticate the photo on original report only *** End of Report ***

Test Report No. SH8071893/CHEM Date: May. 26, 2008 Page 1 of 4 SHANGHAI KAIHONG ELECTRONIC CO., LTD NO.999 CHENCHUN ROAD, SONGJIANG DISTRICT, SHANGHAI, CHINA The following sample(s) was/were submitted and identified by/on behalf of the client as: Sample Name : DIE ATTACHED ADHESIVE SGS Ref No. : 11036937-4 Part No. : 84-1 LIMSR4 Material : SILVER, RESIN Supplier : ABLESTIK Sample Receiving Date : May.22, 2008 Testing Period : May.22 26, 2008 Test Requested Test Method Test Results : In accordance with the RoHS Directive 2002/95/EC, and its amendment directives : (1) With reference to IEC 62321/2 nd CDV (111/95/CDV) for Cadmium content. Analysis was performed by ICP. (2) With reference to IEC 62321/2 nd CDV (111/95/CDV) for Lead content. Analysis was performed by ICP and AAS. (3) With reference to IEC 62321/2 nd CDV (111/95/CDV) for Mercury content. Analysis was performed by ICP. (4) With reference to IEC 62321/2 nd CDV (111/95/CDV) for Hexavalent Chromium by Colorimetric Method. (5) With reference to IEC 62321/2 nd CDV (111/95/CDV) for PBBs / PBDEs content. Analysis was performed by GC/MS. : Please refer to next pages Signed for and on behalf of SGS-CSTC Chemical Laboratory Signed for and on behalf of SGS-CSTC Chemical Laboratory Ella Zhang Section Manager Sandy Hao Lab Manager

Test Report No. SH8071893/CHEM Date: May. 26, 2008 Page 2 of 4 Test results by chemical method (Unit: mg/kg) Test Item(s): Method (refer to) 1 MDL RoHS Limit Cadmium(Cd) (1) ND 2 100 Lead (Pb) (2) ND 2 1000 Mercury (Hg) (3) ND 2 1000 Hexavalent Chromium (CrVI) (4) ND 2 1000 Sum of PBBs ND - 1000 Monobromobiphenyl ND 5 - Dibromobiphenyl ND 5 - Tribromobiphenyl ND 5 - Tetrabromobiphenyl ND 5 - Pentabromobiphenyl ND 5 - Hexabromobiphenyl ND 5 - Heptabromobiphenyl ND 5 - Octabromobiphenyl ND 5 - Nonabromobiphenyl ND 5 - Decabromobiphenyl ND 5 - Sum of PBDEs (Note 4) (5) ND - 1000 Monobromodiphenyl ether ND 5 - Dibromodiphenyl ether ND 5 - Tribromodiphenyl ether ND 5 - Tetrabromodiphenyl ether ND 5 - Pentabromodiphenyl ether ND 5 - Hexabromodiphenyl ether ND 5 - Heptabromodiphenyl ether ND 5 - Octabromodiphenyl ether ND 5 - Nonabromodiphenyl ether ND 5 - Decabromodiphenyl ether ND 5 - Sum of PBDEs (Mono to Deca) ND - - (Result shown is of the total weight of dried sample) Test Part Description: 1. Grey mud Note: (1) mg/kg = ppm (2) ND = (3) MDL = Method Detection Limit (4) Sum of Mono to NonaBDE & according to 2005/717/EC DecaBDE is exempt. (5) - = Not Regulated (6) The maximum permissible limit is quoted from the document 2005/618/EC amending RoHS directive 2002/95/EC

Test Report No. SH8071893/CHEM Date: May. 26, 2008 Page 3 of 4 ATTACHMENTS 1) Name of the person who made measurement: Cathy Cai/George Xu/Diane Wang 2) Name of the person in charge of measurement: Terry Wang/Tracy Yue 3) These samples were dissolved totally by pre-conditioning method according to below flow chart. (Cr6+ and PBBs/PBDEs test method excluded) Sample Preparation Sample Measurement Pb/Cd/Hg PBBs/PBDEs Cr 6+ Acid digestion with microwave/ hotplate Sample solvent extraction Nonmetallic material Metallic material Filtration Concentration/ Dilution of extraction solution Adding extraction solution Positive Spot test Solution Residue Filtration Heating to 90~95 for extraction Boiling water extraction Negative ICP-AES/AAS DATA Total digestion GC/MS DATA Filtration and ph adjustment Adding 1,5- diphenylcarbazide for color development UV-Vis Adding 1,5- diphenylcarbazide for color development A red color indicates the presence of Cr6+. If necessary, confirm with UV-Vis. DATA DATA

Test Report No. SH8071893/CHEM Date: May. 26, 2008 Page 4 of 4 Sample photo: SH8071893/CHEM SGS authenticate the photo on original report only *** End of Report ***

ALS Technichem ( S ) Pte Ltd 14 Little Road #07-01, Singapore 536987 Tel: (65) 6283 9268 Fax: (65) 6283 9689 E-mail: alssg@alsglobal.com Co. Reg No. 198403076R OUR REF NO REPORT : ATS/GR/130/08/sk DATE : 03 March, 2008 Page 1 of 5 COMPANY : Sumitomo Bakelite Singapore Pte Ltd 1 Senoko South Road Singapore 758069 DATE SAMPLE RECEIVED : 26 February, 2008 DATE ANALYSED : 26 February, 2008 DATE COMPLETED : 03 March, 2008 SAMPLE DESCRIPTION : One sample of Chemical was received with references :- Description : EME-6600 Lot No. : 7092296 Type : A TEST REQUESTED TEST METHOD : 1. To determine the Cadmium Content in submitted sample in accordance with EEC Directive 2002/95/EC. 2. To determine the Lead Content in submitted sample in accordance with EEC Directive 2002/95/EC. 3. To determine the Mercury Content in submitted sample in accordance with EEC Directive 2002/95/EC. 4. To determine the Hexavalent Chromium Content in submitted sample in accordance with EEC Directive 2002/95/EC. 5. To determine the PBB in submitted sample in accordance with EEC Directive 2002/95/EC. 6. To determine the PBDE in submitted sample in accordance with EEC Directive 2002/95/EC. : 1. The sample was pre-conditioned with reference to EPA3050B with completely digestion. The analysis was performed by ICP-AES with reference to EPA6010. 2. The sample was pre-conditioned with reference to EPA3050B with completely digestion. The analysis was performed by ICP-AES with reference to EPA6010. 3. The sample was pre-conditioned with reference to EPA3052B with completely digestion. The analysis was performed by Mercury Analyzer. 4. The sample was pre-conditioned with reference to EPA3060A. The analysis was performed by UV-VIS with reference to EPA7196A. 5. The sample was pre-conditioned with reference to EPA 3540C. The analysis was performed by GCMS. 6. The sample was pre-conditioned with reference to EPA 3540C. The analysis was performed by GCMS....2/- This Report shall not be reproduced except in full without prior approval of Management This Report may not be used for advertising purposes

ALS Technichem ( S ) Pte Ltd 14 Little Road #07-01, Singapore 536987 Tel: (65) 6283 9268 Fax: (65) 6283 9689 E-mail: alssg@alsglobal.com Co. Reg No. 198403076R OUR REF NO : ATS/GR/130/08/sk 03 March, 2008 COMPANY : Sumitomo Bakelite Singapore Pte Ltd Page 2 of 5 (Continued) RESULTS : On analysis, the following results were obtained :- Item Tests Results 1 Cadmium (Cd), ppm wt 2 Lead (Pb), ppm wt 3.4 3 Mercury (Hg), ppm wt 4 Hexavalent Chromium (Cr6+), ppm wt 5 6 Polybrominated Biphenyls (PBB) - Monobromobiphenyls - Dibromobiphenyls - Tribromobiphenyls - Etrabromobiphenyls - Pentabromobiphenyls - Hexabromobiphenyls - Heptabromobiphenyls - Octabromobiphenyls - Nonabromobiphenyls - Decabromobiphenyl Polybrominated Diphenyl Ethers (PBDE) - Monobromodiphenyl ethers - Dibromodiphenyl ethers - Tribromodiphenyl ethers - Tetrabromodiphenyl ethers - Pentabromodiphenyl ethers - Hexabromodiphenyl ethers - Heptabromodiphenyl ethers - Octabromodiphenyl ethers - Nonabromodiphenyl ethers - Decabromodiphenyl ethers Notes : 1) ppm wt : mg/kg 2) Detection Limit : a) Cadmium : 2.0 ppm b) Lead : 2.0 ppm c) Mercury : 2.0 ppm d) Hexavalent Chromium : 2.0 ppm e) Polybrominated biphenyls : 5.0 ppm f) Polybrominated diphenyl ethers : 5.0 ppm 3) Above tests were carried out by ALS chemists: Ting Tai Poh, Liang Ye and Geok Cheng Lee. ALS TECHNICHEM (S) PTE LTD YAO KAIWEN, B.SC, M.SC Document Name The ALS Laboratory Group

ALS Technichem ( S ) Pte Ltd 14 Little Road #07-01, Singapore 536987 Tel: (65) 6283 9268 Fax: (65) 6283 9689 E-mail: alssg@alsglobal.com Co. Reg No. 198403076R OUR REF NO : ATS/GR/130/08/sk 03 March, 2008 COMPANY : Sumitomo Bakelite Singapore Pte Ltd Page 3 of 5 (Continued) Measurement Flowchart Sample Small size or powder by grinding, milling or cutting Homogenized test specimens For Cd/Pb/Hg tests For Cr(VI) test Acid digestion with methods: EN1122 (for Cd test on plastic only) or EPA3050B or EPA3052 or EN13346 Totally dissolved Extraction with method EPA3060A Solution Residue Residue appeared Solution Color development and UV-Vis measurement Residue is treated with other acids such as HF, HBF4, HClO4 or other methods such as alkali dissolution, and residue to be dissolved into solution Combine two solutions ICP for Cd/Pb measurement and Mercury analyzer for Hg measurement Document Name The ALS Laboratory Group

ALS Technichem ( S ) Pte Ltd 14 Little Road #07-01, Singapore 536987 Tel: (65) 6283 9268 Fax: (65) 6283 9689 E-mail: alssg@alsglobal.com Co. Reg No. 198403076R OUR REF NO : ATS/GR/130/08/sk 03 March, 2008 COMPANY : Sumitomo Bakelite Singapore Pte Ltd Page 4 of 5 (Continued) Measurement Flowchart Sample Small size or powder by grinding, milling or cutting Homogenized test specimens GC-MS analysis with reference to EPA1614 For PBB & PBDE test Solution Solvent Extraction with method EPA1614 Document Name The ALS Laboratory Group

ALS Technichem ( S ) Pte Ltd 14 Little Road #07-01, Singapore 536987 Tel: (65) 6283 9268 Fax: (65) 6283 9689 E-mail: alssg@alsglobal.com Co. Reg No. 198403076R OUR REF NO : ATS/GR/130/08/sk 03 March, 2008 COMPANY : Sumitomo Bakelite Singapore Pte Ltd Page 5 of 5 (Continued) PHOTO Document Name The ALS Laboratory Group