ICP Test Report Certification Packet Company name: Suzhou Good-Ark Electronics Co.,Ltd. Product Series: SMB SMC Series Product #: SMX GPP(TVS) Diode Issue Date: Sep 1, 2012 It is hereby certified by Suzhou Goodark Electronics CO.,Ltd. that there is neither RoHS (EU Directive 2002/95/EC)-restricted substance nor such use, for materials to be used for unit parts, for packing/packaging materials, and for additives and the like in the manufacturing processes. In addition, it is hereby reported to you that the parts and sub-materials, the materials to be used for unit parts, the packing/packaging materials, and the additives and the like in the manufacturing processes, are all composed of the following components. Issued by: Global EHS Engineer (1) Parts, sub-materials and unit parts This document covers the SMB SMC Series RoHS-Compliant series products manufactured by Littelfuse, Inc. <Raw Materials Used Please see Table 1 > (2) The ICP data on all measurable substances Please see appropriate pages as identifed in Table 1 Remarks:under RoHS Exemptions 5 (7c-1 in the New RoHS exemption) and 7a apply to these products. Rev. A 09/01/12 Page 1
Table 1: List of Raw Materials covered by this report Total Parts Raw Material Description Test Ruesult Page(s) 1 Lead Frame 2 Dice 3 Solder Chip 4 Molding Compound 5 Halogen free Molding compound 6 Plating Cd: Pb: Hg: Cr6+:N PBBs: PBDEs: Cd: Pb:44347 Hg: Cr6+:N PBBs: PBDEs: Cd: Pb:920800 Hg: Cr6+:N PBBs: PBDEs: Cd: Pb: Hg: Cr6+: PBBs: PBDEs: Cd: Pb: Hg: Cr6+: PBBs: PBDEs: F: Cl:89 Br: I: Cd: Pb:230 Hg: Cr6+:N PBBs: PBDEs: 3-7 8-15 16-20 21-25 26-32 33-37 Page 2
WUXH00009676 Applicant : SUZHOU GOODARK ELECTRONICS CO., LTD. Date : Jul 26, 2012 NO.31 TONGXI ROAD, TONGAN ECONOMIC DEVELOPMENT ZONE, SUZHOU, P.R.CHINA Attn : MIAO XIAOQING Sample Description As Declared: One (1) Piece Of Submitted Sample Said To Be : Copper Metal. Sample Item : Lead Frame. Material Spec : C1921. Remark : As Requested By The Applicant, Tested As A Whole And Sampled Randomly. Tests Conducted: As Requested By The Applicant, For Details Refer To Attached Pages Prepared And Checked By: For Jessica Lu General Manager Page 1 Of 5
WUXH00009676 1 RoHS Directives Test (A) Test Result Summary: Testing Item Cadmium (Cd) Content (mg/kg) Lead (Pb) Content (mg/kg) Mercury (Hg) Content (mg/kg) Chromium (VI)(Cr 6+ ) Result (By Boiling Water Extraction On Metal) (mg/kg With 50cm 2 ) Polybrominated Biphenyls (PBBs)(mg/kg) Monobrominated Biphenyls (MonoBB) Dibrominated Biphenyls (DiBB) Tribrominated Biphenyls (TriBB) Tetrabrominated Biphenyls (TetraBB) Pentabrominated Biphenyls (PentaBB) Hexabrominated Biphenyls (HexaBB) Heptabrominated Biphenyls (HeptaBB) Octabrominated Biphenyls (OctaBB) Nonabrominated Biphenyls (NonaBB) Decabrominated Biphenyl (DecaBB) Polybrominated Diphenyl Ethers (PBDEs)(mg/kg) Monobrominated Diphenyl Ethers (MonoBDE) Dibrominated Diphenyl Ethers (DiBDE) Tribrominated Diphenyl Ethers (TriBDE) Tetrabrominated Diphenyl Ethers (TetraBDE) Pentabrominated Diphenyl Ethers (PentaBDE) Hexabrominated Diphenyl Ethers (HexaBDE) Heptabrominated Diphenyl Ethers (HeptaBDE) Octabrominated Diphenyl Ethers (OctaBDE) Nonabrominated Diphenyl Ethers (NonaBDE) Decabrominated Diphenyl Ether (DecaBDE) Result N Remark: mg/kg = Milligram Per Kilogram = ppm mg/kg With 50cm 2 = Milligram Per Kilogram With 50 Square Centimeter = Not Detected N=Negative Page 2 Of 5
WUXH00009676 (B)RoHS Requirement: Restricted Substances Limits Cadmium (Cd) 0.01% (100 mg/kg) Lead (Pb) Mercury (Hg) Chromium (VI) (Cr 6+ ) Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ethers (PBDEs) The Above Limits Were Quoted From 2002/95/EC And Amendment 2005/618/EC For Homogeneous Material. (C) Test Method: Testing Item Testing Method Reporting Limit Cadmium (Cd)Content Lead (Pb)Content Mercury (Hg)Content Chromium (VI) (Cr 6+ ) Content (For Metal) Polybrominated Biphenyls (PBBs)& Polybrominated Diphenyl Ethers (PBDEs) Date Sample Received: Jul 20, 2012 Testing Period: Jul 20, 2012To Jul 26, 2012 With Reference To IEC 62321 Edition 1.0: 2008, By Acid Digestion And Determined By ICP-OES With Reference To IEC 62321 Edition 1.0: 2008, By Acid Digestion And Determined By ICP-OES With Reference To IEC 62321 Edition 1.0: 2008, By Acid Digestion And Determined By ICP-OES With Reference To IEC 62321 Edition 1.0: 2008, By Boiling Water Extraction And Determined By UV-VIS Spectrophotometer With Reference To IEC 62321 Edition 1.0: 2008, By Solvent Extraction And Determined By GC-MSD And Further HPLC Confirmation When Necessary. 2 mg/kg 2 mg/kg 2 mg/kg 0.02mg/kg With 50cm 2 (In Testing Solution) 5 mg/kg Page 3 Of 5
WUXH00009676 (D) Measurement Flowchart: Reference Standard: IEC 62321 Edition 1.0: 2008 Sampling/Grinding Or Cutting Cd/Pb/Hg Cr 6+ PBBs/PBDEs For Different Material, Digest The Sample With Appropriate Acid *1 Metal Get 50cm 2 Samples Weigh Sample And Add Organic Solvent Confirm The Tested Samples Are Totally Dissolved Yes No Boiling Water Extraction Soxhlet Extraction Or Solvent Extraction Make Up With Deionized Water Analyzed By ICP-OES Make Up With Deionized Water And Add Diphenyl- Carbazide Solution Concentrate The Extract And Make Up With Organic Solvent Analyzed By UV-VIS Analyzed By GC-MSD Chemist: Inorganic (Ann Luo/Fred Wang/Ally Wan) Organic (Jenny Xu/Cherry Sun) Remarks: *1: List Of Appropriate Acid: Material Acid Added For Digestion Polymers HNO 3, HCL,HF,H 2 O 2, H 3 BO 3 Metals HNO 3, HCL,HF Electronics HNO 3, HCL,H 2 O 2, HBF 4 Page 4 Of 5
WUXH00009676 Photo This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. Page 5 Of 5
WUXH00009687 Applicant : SUZHOU GOODARK ELECTRONICS CO., LTD. Date : Jul 27, 2012 NO.31 TONGXI ROAD, TONGAN ECONOMIC DEVELOPMENT ZONE, SUZHOU, P.R.CHINA Attn : MIAO XIAOQING Sample Description As Declared: One (1) Piece Of Submitted Sample Said To Be : Silvery Grey Solder Chip. Sample Item : Solder Chip. Material Spec : Pb92.5/Sn5/Ag2.5. Tests Conducted: As Requested By The Applicant, For Details Refer To Attached Pages Prepared And Checked By: For Jessica Lu General Manager Page 1 Of 5
WUXH00009687 1 RoHS Directives Test (A) Test Result Summary: Testing Item Result Cadmium (Cd) Content (mg/kg) Lead (Pb) Content (mg/kg) 920800#1 Mercury (Hg) Content (mg/kg) Chromium (VI)(Cr 6+ ) Result (By Boiling Water Extraction On Metal) (mg/kg With 50cm 2 ) N Polybrominated Biphenyls (PBBs)(mg/kg) Monobrominated Biphenyls (MonoBB) Dibrominated Biphenyls (DiBB) Tribrominated Biphenyls (TriBB) Tetrabrominated Biphenyls (TetraBB) Pentabrominated Biphenyls (PentaBB) Hexabrominated Biphenyls (HexaBB) Heptabrominated Biphenyls (HeptaBB) Octabrominated Biphenyls (OctaBB) Nonabrominated Biphenyls (NonaBB) Decabrominated Biphenyl (DecaBB) Polybrominated Diphenyl Ethers (PBDEs)(mg/kg) Monobrominated Diphenyl Ethers (MonoBDE) Dibrominated Diphenyl Ethers (DiBDE) Tribrominated Diphenyl Ethers (TriBDE) Tetrabrominated Diphenyl Ethers (TetraBDE) Pentabrominated Diphenyl Ethers (PentaBDE) Hexabrominated Diphenyl Ethers (HexaBDE) Heptabrominated Diphenyl Ethers (HeptaBDE) Octabrominated Diphenyl Ethers (OctaBDE) Nonabrominated Diphenyl Ethers (NonaBDE) Decabrominated Diphenyl Ether (DecaBDE) Remark: mg/kg = Milligram Per Kilogram = ppm mg/kg With 50cm 2 = Milligram Per Kilogram With 50 Square Centimeter = Not Detected N=Negative #1 = As Claimed By The Declaration Submitted By The Client, The Lead Content Of The Component Is Coming From The Constituent Of High Melting Temperature Type Solders (I.E. Lead Based Alloys Containing 85% By Weight Or More Lead) Only. According To EU RoHS Directive (2002/95/EC) And Its Amendments, Lead In High Melting Temperature Type Solders Of This Component Can Be Exempted. Page 2 Of 5
WUXH00009687 (B)RoHS Requirement: Restricted Substances Limits Cadmium (Cd) 0.01% (100 mg/kg) Lead (Pb) Mercury (Hg) Chromium (VI) (Cr 6+ ) Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ethers (PBDEs) The Above Limits Were Quoted From 2002/95/EC And Amendment 2005/618/EC For Homogeneous Material. (C) Test Method: Testing Item Testing Method Reporting Limit Cadmium (Cd)Content Lead (Pb)Content Mercury (Hg)Content Chromium (VI) (Cr 6+ ) Content (For Metal) Polybrominated Biphenyls (PBBs)& Polybrominated Diphenyl Ethers (PBDEs) Date Sample Received: Jul 20, 2012 Testing Period: Jul 20, 2012 To Jul 26, 2012 With Reference To IEC 62321 Edition 1.0: 2008, By Acid Digestion And Determined By ICP-OES With Reference To IEC 62321 Edition 1.0: 2008, By Acid Digestion And Determined By ICP-OES With Reference To IEC 62321 Edition 1.0: 2008, By Acid Digestion And Determined By ICP-OES With Reference To IEC 62321 Edition 1.0: 2008, By Boiling Water Extraction And Determined By UV-VIS Spectrophotometer With Reference To IEC 62321 Edition 1.0: 2008, By Solvent Extraction And Determined By GC-MSD And Further HPLC Confirmation When Necessary. 2 mg/kg 2 mg/kg 2 mg/kg 0.02mg/kg With 50cm 2 (In Testing Solution) 5 mg/kg Page 3 Of 5
WUXH00009687 (D) Measurement Flowchart: Reference Standard: IEC 62321 Edition 1.0: 2008 Sampling/Grinding Or Cutting Cd/Pb/Hg Cr 6+ PBBs/PBDEs For Different Material, Digest The Sample With Appropriate Acid *1 Metal Get 50cm 2 Samples Weigh Sample And Add Organic Solvent Confirm The Tested Samples Are Totally Dissolved Yes No Boiling Water Extraction Soxhlet Extraction Or Solvent Extraction Make Up With Deionized Water Analyzed By ICP-OES Make Up With Deionized Water And Add Diphenyl- Carbazide Solution Concentrate The Extract And Make Up With Organic Solvent Analyzed By UV-VIS Analyzed By GC-MSD Chemist: Inorganic (Ann Luo/Fred Wang/Ally Wan) Organic (Jenny Xu/Cherry Sun) Remarks: *1: List Of Appropriate Acid: Material Acid Added For Digestion Polymers HNO 3, HCL,HF,H 2 O 2, H 3 BO 3 Metals HNO 3, HCL,HF Electronics HNO 3, HCL,H 2 O 2, HBF 4 Page 4 Of 5
WUXH00009687 Photo This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. Page 5 Of 5
WUXH00009694 Applicant : SUZHOU GOODARK ELECTRONICS CO., LTD. Date : Jul 26, 2012 NO.31 TONGXI ROAD, TONGAN ECONOMIC DEVELOPMENT ZONE, SUZHOU, P.R.CHINA Attn : MIAO XIAOQING Sample Description As Declared: One (1) Piece Of Submitted Sample Said To Be : Black Plastic. Sample Item : Molding Compound. Material Spec : EME-1100,EME-1200,EME-2100,EME-2500,EME- 5000N,EME5000VR,EME5051S,EME5500F,EME-5500FL,EME-5500FR,EME- 5961,EME-220L,EC-11,EC-12,ER100,ER200 Series. Tests Conducted: As Requested By The Applicant, For Details Refer To Attached Pages Summary: Tested Sample Standard Result Submitted Sample With Reference To Test Method Of IEC 62321 Edition 1.0: 2008 And Maximum Concentration Limits Quoted From RoHS Directives 2002/95/EC And Amendment 2005/618/EC Pass Prepared And Checked By: For Jessica Lu General Manager Page 1 Of 5
WUXH00009694 1 RoHS Directives Test (A) Test Result Summary: Testing Item Cadmium (Cd) Content (mg/kg) Lead (Pb) Content (mg/kg) Mercury (Hg) Content (mg/kg) Chromium (VI) (Cr 6+ ) Content (mg/kg)(for Non-Metal) Polybrominated Biphenyls (PBBs)(mg/kg) Monobrominated Biphenyls (MonoBB) Dibrominated Biphenyls (DiBB) Tribrominated Biphenyls (TriBB) Tetrabrominated Biphenyls (TetraBB) Pentabrominated Biphenyls (PentaBB) Hexabrominated Biphenyls (HexaBB) Heptabrominated Biphenyls (HeptaBB) Octabrominated Biphenyls (OctaBB) Nonabrominated Biphenyls (NonaBB) Decabrominated Biphenyl (DecaBB) Polybrominated Diphenyl Ethers (PBDEs)(mg/kg) Monobrominated Diphenyl Ethers (MonoBDE) Dibrominated Diphenyl Ethers (DiBDE) Tribrominated Diphenyl Ethers (TriBDE) Tetrabrominated Diphenyl Ethers (TetraBDE) Pentabrominated Diphenyl Ethers (PentaBDE) Hexabrominated Diphenyl Ethers (HexaBDE) Heptabrominated Diphenyl Ethers (HeptaBDE) Octabrominated Diphenyl Ethers (OctaBDE) Nonabrominated Diphenyl Ethers (NonaBDE) Decabrominated Diphenyl Ether (DecaBDE) Result Remark: mg/kg = Milligram Per Kilogram = ppm = Not Detected Page 2 Of 5
WUXH00009694 (B)RoHS Requirement: Restricted Substances Limits Cadmium (Cd) 0.01% (100 mg/kg) Lead (Pb) Mercury (Hg) Chromium (VI) (Cr 6+ ) Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ethers (PBDEs) The Above Limits Were Quoted From 2002/95/EC And Amendment 2005/618/EC For Homogeneous Material. (C) Test Method: Testing Item Testing Method Reporting Limit Cadmium (Cd)Content Lead (Pb)Content Mercury (Hg)Content Chromium (VI) (Cr 6+ ) Content (For Non-Metal) Polybrominated Biphenyls (PBBs)& Polybrominated Diphenyl Ethers (PBDEs) Date Sample Received: Jul 20, 2012 Testing Period: Jul 20, 2012 To Jul 26,2012 With Reference To IEC 62321 Edition 1.0: 2008, By Acid Digestion And Determined By ICP-OES With Reference To IEC 62321 Edition 1.0: 2008, By Acid Digestion And Determined By ICP-OES With Reference To IEC 62321 Edition 1.0: 2008, By Acid Digestion And Determined By ICP-OES With Reference To IEC 62321 Edition 1.0: 2008, By Alkaline Digestion And Determined By UV-VIS Spectrophotometer With Reference To IEC 62321 Edition 1.0: 2008, By Solvent Extraction And Determined By GC-MSD And Further HPLC Confirmation When Necessary. 2 mg/kg 2 mg/kg 2 mg/kg 1 mg/kg 5 mg/kg Page 3 Of 5
WUXH00009694 (D) Measurement Flowchart: Reference Standard: IEC 62321 Edition 1.0: 2008 Sampling/Grinding Or Cutting Cd/Pb/Hg Cr 6+ Polymers / Electronics PBBs/PBDEs For Different Material, Digest The Sample With Appropriate Acid *1 Weigh Sample And Add Alkaline Solution Weigh Sample And Add Organic Solvent Confirm The Tested Samples Are Totally Dissolved Yes No Definite Temp. Extraction Soxhlet Extraction Or Solvent Extraction Make Up With Deionized Water Analyzed By ICP-OES Cool And Filter The Extract Make Up With Deionized Water And Add Diphenyl- Carbazide Solution Concentrate The Extract And Make Up With Organic Solvent Analyzed By GC-MSD Analyzed By UV-VIS Chemist: Inorganic (Ann Luo/Fred Wang/Ally Wan) Organic (Jenny Xu/Cherry Sun) Remarks: *1: List Of Appropriate Acid: Material Acid Added For Digestion Polymers HNO 3, HCL,HF,H 2 O 2, H 3 BO 3 Metals HNO 3, HCL,HF Electronics HNO 3, HCL,H 2 O 2, HBF 4 Page 4 Of 5
WUXH00009694 Photo This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. Page 5 Of 5
WUXH00009696 Applicant : SUZHOU GOODARK ELECTRONICS CO., LTD. Date : Jul 30, 2012 NO.31 TONGXI ROAD, TONGAN ECONOMIC DEVELOPMENT ZONE, SUZHOU, P.R.CHINA Attn : MIAO XIAOQING Sample Description As Declared: One (1) Piece Of Submitted Sample Said To Be : Black Epoxy Resin. Sample Item : Halogen Free Molding Compound. Material Spec : EK-1700G, EK-1700GH, EK-1700GO. Tests Conducted: As Requested By The Applicant, For Details Refer To Attached Pages Summary: Tested Sample Standard Result Submitted Sample With Reference To Test Method Of IEC 62321 Edition 1.0: 2008 And Maximum Concentration Limits Quoted From RoHS Directives 2002/95/EC And Amendment 2005/618/EC Pass Prepared And Checked By: For Jessica Lu General Manager Page 1 Of 7
WUXH00009696 1 RoHS Directives Test (A) Test Result Summary: Testing Item Cadmium (Cd) Content (mg/kg) Lead (Pb) Content (mg/kg) Mercury (Hg) Content (mg/kg) Chromium (VI) (Cr 6+ ) Content (mg/kg)(for Non-Metal) Polybrominated Biphenyls (PBBs)(mg/kg) Monobrominated Biphenyls (MonoBB) Dibrominated Biphenyls (DiBB) Tribrominated Biphenyls (TriBB) Tetrabrominated Biphenyls (TetraBB) Pentabrominated Biphenyls (PentaBB) Hexabrominated Biphenyls (HexaBB) Heptabrominated Biphenyls (HeptaBB) Octabrominated Biphenyls (OctaBB) Nonabrominated Biphenyls (NonaBB) Decabrominated Biphenyl (DecaBB) Polybrominated Diphenyl Ethers (PBDEs)(mg/kg) Monobrominated Diphenyl Ethers (MonoBDE) Dibrominated Diphenyl Ethers (DiBDE) Tribrominated Diphenyl Ethers (TriBDE) Tetrabrominated Diphenyl Ethers (TetraBDE) Pentabrominated Diphenyl Ethers (PentaBDE) Hexabrominated Diphenyl Ethers (HexaBDE) Heptabrominated Diphenyl Ethers (HeptaBDE) Octabrominated Diphenyl Ethers (OctaBDE) Nonabrominated Diphenyl Ethers (NonaBDE) Decabrominated Diphenyl Ether (DecaBDE) Result Remark: mg/kg = Milligram Per Kilogram = ppm = Not Detected Page 2 Of 7
WUXH00009696 (B)RoHS Requirement: Restricted Substances Limits Cadmium (Cd) 0.01% (100 mg/kg) Lead (Pb) Mercury (Hg) Chromium (VI) (Cr 6+ ) Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ethers (PBDEs) The Above Limits Were Quoted From 2002/95/EC And Amendment 2005/618/EC For Homogeneous Material. (C) Test Method: Testing Item Testing Method Reporting Limit Cadmium (Cd)Content Lead (Pb)Content Mercury (Hg)Content Chromium (VI) (Cr 6+ ) Content (For Non-Metal) Polybrominated Biphenyls (PBBs)& Polybrominated Diphenyl Ethers (PBDEs) Date Sample Received: Jul 20, 2012 Testing Period: Jul 20, 2012 To Jul 27,2012 With Reference To IEC 62321 Edition 1.0: 2008, By Acid Digestion And Determined By ICP-OES With Reference To IEC 62321 Edition 1.0: 2008, By Acid Digestion And Determined By ICP-OES With Reference To IEC 62321 Edition 1.0: 2008, By Acid Digestion And Determined By ICP-OES With Reference To IEC 62321 Edition 1.0: 2008, By Alkaline Digestion And Determined By UV-VIS Spectrophotometer With Reference To IEC 62321 Edition 1.0: 2008, By Solvent Extraction And Determined By GC-MSD And Further HPLC Confirmation When Necessary. 2 mg/kg 2 mg/kg 2 mg/kg 1 mg/kg 5 mg/kg Page 3 Of 7
WUXH00009696 (D) Measurement Flowchart: Reference Standard: IEC 62321 Edition 1.0: 2008 Sampling/Grinding Or Cutting Cd/Pb/Hg Cr 6+ Polymers / Electronics PBBs/PBDEs For Different Material, Digest The Sample With Appropriate Acid *1 Weigh Sample And Add Alkaline Solution Weigh Sample And Add Organic Solvent Confirm The Tested Samples Are Totally Dissolved Yes No Definite Temp. Extraction Soxhlet Extraction Or Solvent Extraction Make Up With Deionized Water Analyzed By ICP-OES Cool And Filter The Extract Make Up With Deionized Water And Add Diphenyl- Carbazide Solution Concentrate The Extract And Make Up With Organic Solvent Analyzed By GC-MSD Analyzed By UV-VIS Chemist: Inorganic (Ann Luo/Fred Wang/Ally Wan) Organic (Jenny Xu/Cherry Sun) Remarks: *1: List Of Appropriate Acid: Material Acid Added For Digestion Polymers HNO 3, HCL,HF,H 2 O 2, H 3 BO 3 Metals HNO 3, HCL,HF Electronics HNO 3, HCL,H 2 O 2, HBF 4 Page 4 Of 7
WUXH00009696 2 Halogen Test (I) Test Result Summary : Halogen Content: Testing Item Result (ppm) Submitted Samples Fluorine (F) Content Chlorine (Cl)Content 89 Bromine (Br) Content Iodine (I) Content Remarks : ppm = Parts Per Million = mg/kg = Not Detected Date Sample Received: Jul 20, 2012 Testing Period: Jul 20, 2012 To Jul 27,2012 (II) Test Method : Testing Item Testing Method With Reference To EN 14582:2007 By Combustion In A Halogen (F,Cl, Br,I) Content Calorimetric Bomb And Determined By Ion Chromatography Remarks : Reporting Limit = Quantitation Limit Of Analyte In Sample Reporting Limit 50 ppm Page 5 Of 7
WUXH00009696 (III) Measurement Flowchart: Test For Halogen Content Reference Method: EN 14582:2007 Sampling/Grinding Or Cutting Add Absorbent In A Combustion Flask & Place Weighed Sample In Fill The Calorimetric Bomb With Oxygen Ignite Then Leave The Flask At Room Temperature Any Test Specimen In The Olorimetric Bomb? Yes No Transfer The Absorbent Into A Volumetric Flask Make Up With Deionized Water Analyzed By Ion Chromatography Chemist: Fred Wang/ Ally Wan Ally Wan Page 6 Of 7
WUXH00009696 Photo This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. Page 7 Of 7
WUXH00009701 Applicant : SUZHOU GOODARK ELECTRONICS CO., LTD. Date : Jul 26, 2012 NO.31 TONGXI ROAD, TONGAN ECONOMIC DEVELOPMENT ZONE, SUZHOU, P.R.CHINA Attn : MIAO XIAOQING Sample Description As Declared: One (1) Piece Of Submitted Sample Said To Be : Silvery Grey Metal. Sample Item : Tin Ingot. Material Spec : 99.9% Sn. Tests Conducted: As Requested By The Applicant, For Details Refer To Attached Pages Summary: Tested Sample Standard Result Submitted Sample With Reference To Test Method Of IEC 62321 Edition 1.0: 2008 And Maximum Concentration Limits Quoted From RoHS Directives 2002/95/EC And Amendment 2005/618/EC Pass Prepared And Checked By: For Jessica Lu General Manager Page 1 Of 5
WUXH00009701 1 RoHS Directives Test (A) Test Result Summary: Testing Item Result Cadmium (Cd) Content (mg/kg) Lead (Pb) Content (mg/kg) 230 Mercury (Hg) Content (mg/kg) Chromium (VI)(Cr 6+ ) Result (By Boiling Water Extraction On Metal) (mg/kg With 50cm 2 ) N Polybrominated Biphenyls (PBBs)(mg/kg) Monobrominated Biphenyls (MonoBB) Dibrominated Biphenyls (DiBB) Tribrominated Biphenyls (TriBB) Tetrabrominated Biphenyls (TetraBB) Pentabrominated Biphenyls (PentaBB) Hexabrominated Biphenyls (HexaBB) Heptabrominated Biphenyls (HeptaBB) Octabrominated Biphenyls (OctaBB) Nonabrominated Biphenyls (NonaBB) Decabrominated Biphenyl (DecaBB) Polybrominated Diphenyl Ethers (PBDEs)(mg/kg) Monobrominated Diphenyl Ethers (MonoBDE) Dibrominated Diphenyl Ethers (DiBDE) Tribrominated Diphenyl Ethers (TriBDE) Tetrabrominated Diphenyl Ethers (TetraBDE) Pentabrominated Diphenyl Ethers (PentaBDE) Hexabrominated Diphenyl Ethers (HexaBDE) Heptabrominated Diphenyl Ethers (HeptaBDE) Octabrominated Diphenyl Ethers (OctaBDE) Nonabrominated Diphenyl Ethers (NonaBDE) Decabrominated Diphenyl Ether (DecaBDE) Remark: mg/kg = Milligram Per Kilogram = ppm mg/kg With 50cm 2 = Milligram Per Kilogram With 50 Square Centimeter = Not Detected N=Negative Page 2 Of 5
WUXH00009701 (B)RoHS Requirement: Restricted Substances Limits Cadmium (Cd) 0.01% (100 mg/kg) Lead (Pb) Mercury (Hg) Chromium (VI) (Cr 6+ ) Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ethers (PBDEs) The Above Limits Were Quoted From 2002/95/EC And Amendment 2005/618/EC For Homogeneous Material. (C) Test Method: Testing Item Testing Method Reporting Limit Cadmium (Cd)Content Lead (Pb)Content Mercury (Hg)Content Chromium (VI) (Cr 6+ ) Content (For Metal) Polybrominated Biphenyls (PBBs)& Polybrominated Diphenyl Ethers (PBDEs) Date Sample Received: Jul 20, 2012 Testing Period: Jul 20, 2012To Jul 26, 2012 With Reference To IEC 62321 Edition 1.0: 2008, By Acid Digestion And Determined By ICP-OES With Reference To IEC 62321 Edition 1.0: 2008, By Acid Digestion And Determined By ICP-OES With Reference To IEC 62321 Edition 1.0: 2008, By Acid Digestion And Determined By ICP-OES With Reference To IEC 62321 Edition 1.0: 2008, By Boiling Water Extraction And Determined By UV-VIS Spectrophotometer With Reference To IEC 62321 Edition 1.0: 2008, By Solvent Extraction And Determined By GC-MSD And Further HPLC Confirmation When Necessary. 2 mg/kg 2 mg/kg 2 mg/kg 0.02mg/kg With 50cm 2 (In Testing Solution) 5 mg/kg Page 3 Of 5
WUXH00009701 (D) Measurement Flowchart: Reference Standard: IEC 62321 Edition 1.0: 2008 Sampling/Grinding Or Cutting Cd/Pb/Hg Cr 6+ PBBs/PBDEs For Different Material, Digest The Sample With Appropriate Acid *1 Metal Get 50cm 2 Samples Weigh Sample And Add Organic Solvent Confirm The Tested Samples Are Totally Dissolved Yes No Boiling Water Extraction Soxhlet Extraction Or Solvent Extraction Make Up With Deionized Water Analyzed By ICP-OES Make Up With Deionized Water And Add Diphenyl- Carbazide Solution Concentrate The Extract And Make Up With Organic Solvent Analyzed By UV-VIS Analyzed By GC-MSD Chemist: Inorganic (Ann Luo/Fred Wang/Ally Wan) Organic (Jenny Xu/Cherry Sun) Remarks: *1: List Of Appropriate Acid: Material Acid Added For Digestion Polymers HNO 3, HCL,HF,H 2 O 2, H 3 BO 3 Metals HNO 3, HCL,HF Electronics HNO 3, HCL,H 2 O 2, HBF 4 Page 4 Of 5
WUXH00009701 Photo This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. Page 5 Of 5