LightLab I N T E R N A T I O N A L

Similar documents
LightLab I N T E R N A T I O N A L

LightLab I N T E R N A T I O N A L

LightLab I N T E R N A T I O N A L

LightLab I N T E R N A T I O N A L

Report of Test LLIA A

Report of Test LLIA A

Report of Test LLIA A

LightLab I N T E R N A T I O N A L

LightLab I N T E R N A T I O N A L

Report No.: HZ p. (Lumens) Stabilization Time CRI (K)

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT8N20-A

LM Test Report. for. Forest Lighting Corporate. LED Tube. Model: FL-T8U BN

LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl350u1

NVLAP LAB CODE LM Test Report. For REMPHOS TECHNOLOGIES LLC. (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA.

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT5Z02-6

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT5Z02-9

NVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl5s50u1

NVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl4s50u1

NVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS350U1. Model differences: N/A

NVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS450U1. Model differences: N/A

Report of Test LLIA

IES LM MEASUREMENT AND TEST REPORT For. ATG Electronics Corp Rancho Park Court Rancho Cucamonga, CA Test Model: HBUF-150W-50

Report of Test LLIA

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

LM Test Report. For MaxLite Inc. LED Commercial Down lights Model: RR82540W

NVLAP LAB CODE LM Test Report. For IGT LIGHTING INC. (Brand Name: IG T ) 3755 Lincoln St. Suite B, Riverside, CA 92503

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK)

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

IES LM MEASUREMENT AND TEST REPORT For. ATG Electronics Corp 9020 Rancho Park Court Rancho Cucamonga, CA Test Model: HBUF-100W-50

LM Test Report. For. Beyond LED Technology. (Brand Name: Beyond LED) 2725 Mountain Industrial Blvd. Suite A-1 Tucker, GA 30084

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

Report of Test LLIA

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For. Shenzhen Guanke Technologies Co. Ltd. (Brand Name: )

NVLAP LAB CODE LM Test Report. For LED PANEL LIGHTING CO.,LTD. (Brand Name: N/A)

Report of Test LLIA

Photometric Test Report

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK)

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

NVLAP LAB CODE LM Test Report. For CE INNOVATIONS LTD. (Brand Name: N/A) 911 Denison St Markham, ON L3R 3K4 Canada

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE MANUFACTURE NAME 8165 E. KAISER BLVD, ANAHEIM, CA 92808

NVLAP LAB CODE LM Test Report. For. LED Wav es,inc. (Brand Name: LED Wav es)

IES LM MEASUREMENT AND TEST REPORT For. IGT LIGHTING INC Lincoln St. Suite B, Riverside, CA Test Model: IGTFL

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

LM Test Report. For Elec-Tech International Co., Ltd. T8 LED TUBE Model: XX(XX:41-50)

LM Test Report. For Elec-Tech International Co., Ltd. T8 LED TUBE Model: XX(XX:41-50)

Model No Stock No Calibration Due Date Chroma Programmable AC Source PS-AC02

NVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd (Brand Name: SEPICN LED LIGHTING)

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD

GM LIGHTING 9830 W 190th St, Torrance, CA 90503

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

IES LM MEASUREMENT AND TEST REPORT. For

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Page 2 of 14 Report No.: Test sample... : Type of test object... : LED Downlight LED Downlight

IES LM MEASUREMENT AND TEST REPORT. For

IES LM MEASUREMENT AND TEST REPORT. For

IES LM MEASUREMENT AND TEST REPORT. For

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

IES LM MEASUREMENT AND TEST REPORT For

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Calibration Due Date Chroma Programmable AC Source 61604

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Model No Stock No Calibration Due Date Chroma Programmable AC Source PS-AC02

LED Entryway Light RoHS

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Checked X.CAO

PHOTOMETRIC TESTING & EVALUATION TO IES LM Sample Tested LN130-A30 LED HIGH BAY. Prepared for: Janie Chung

Standard-Tech Co. Ltd Testing Center

Checked X.CAO

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Maxlite Jersey Blvd Rancho Cucamonga, CA Electrical and Photometric tests as required by the IESNA test standards.

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Fixture is tested with no special conditions.

NVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd (Brand Name: SEPICN LED LIGHTING)

RoHS. Dimming: PWM/VR/0-10V QPL ID # PL21D5Q1B95E. Cat# W LED FlatPanel Slipfitter Mount. EPA Rating 2.

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cat# LED High Bay

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Transcription:

Report of Test 13232-2 Performance Summary Total Light Output Luminaire Power Luminous Efficacy 3287 lm 35.6 W 92.3 lm/w PREPARED FOR : Ecolite Manufacturing, 9919 East Montgomery, Spokane, WA 99206. Page 1 of 8 ES

Back of panel and retrofit Driver label Rear product label Page 2 of 8 ES

LM-79 Performance Data Spectral CIE 1931 (x, y) (1) (0.343, 0.359) (1) CIE 1976 (u', v') (0.208, 0.488) Correlated Color Temperature (CCT) (1) 5090 K Color Spatial Uniformity (2) 0.0005 Color Rendering Index (Ra) (1) 81.0 (1),(3) Special CRI 9 (R 9 ) 13 (1),(3) Distance from Planckian Locus (Duv) 0.0041 (1),(3) Scotopic/Photopic Ratio 1.92 Electrical Voltage 120.0 V (Setpoint 1) Frequency 60 Hz Current 0.307 A Power 35.6 W Power Factor 0.97 Current THD 6.25 % Voltage 277.0 V (Setpoint 2) Frequency 60 Hz Current 0.142 A Power 35.4 W Power Factor 0.90 Current THD 6.79 % Performance data in accordance with IESNA LM-79-08. Spectral calculations are for a CIE 2 observer Photometric and spectral values were measured at Setpoint 1 (1) Value is computed from the weighted average of the spatial measurements (2) Value is the maximum deviation of the spatial u' and v' measurements from the weighted average (3) Quantity is in addition to the scope of IESNA LM-79-08 Page 3 of 8 ES

LM-79 Performance Data Summary Relative Spectral Irradiance Distribution (wavelength nm, irradiance relative to peak = 1) 380 0.00E+00 480 2.00E-01 580 5.76E-01 680 1.67E-01 385 0.00E+00 485 2.41E-01 585 5.68E-01 685 1.48E-01 390 0.00E+00 490 2.97E-01 590 5.59E-01 690 1.29E-01 395 0.00E+00 495 3.55E-01 595 5.49E-01 695 1.12E-01 400 2.12E-05 500 4.05E-01 600 5.38E-01 700 9.77E-02 405 1.44E-03 505 4.42E-01 605 5.24E-01 705 8.32E-02 410 8.77E-03 510 4.70E-01 610 5.08E-01 710 7.00E-02 415 2.88E-02 515 4.90E-01 615 4.89E-01 715 5.86E-02 420 7.26E-02 520 5.06E-01 620 4.68E-01 720 4.74E-02 425 1.67E-01 525 5.20E-01 625 4.46E-01 725 3.83E-02 430 3.19E-01 530 5.35E-01 630 4.23E-01 730 3.06E-02 435 5.39E-01 535 5.49E-01 635 3.98E-01 735 2.41E-02 440 8.41E-01 540 5.63E-01 640 3.74E-01 740 1.95E-02 445 9.93E-01 545 5.74E-01 645 3.46E-01 745 1.45E-02 Relative Spectral Power 450 7.48E-01 550 5.83E-01 650 3.19E-01 750 1.06E-02 455 4.51E-01 555 5.90E-01 655 2.91E-01 755 6.96E-03 460 3.20E-01 560 5.94E-01 660 2.65E-01 760 2.39E-03 465 2.33E-01 565 5.94E-01 665 2.38E-01 765 6.74E-04 470 1.79E-01 570 5.90E-01 670 2.12E-01 770 6.73E-04 475 1.76E-01 575 5.85E-01 675 1.90E-01 775 2.11E-04 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 * The spectral power distribution combines the weighted spectral power distributions of all spatial measurements. 780 0.00E+00 380 400 420 440 460 480 500 520 540 560 580 600 620 640 660 680 700 720 740 760 780 Wavelength (nm) Page 4 of 8 ES

LM-79 Performance Data Spatial measurements (lower hemisphere) Spatial measurements (upper hemisphere) Vertical CIE 1976 (u',v') coordinates Vertical CIE 1976 (u',v') coordinates angle (deg) Horizontal 0 plane Horizontal 90 plane angle (deg) Horizontal 0 plane Horizontal 90 plane 0 (0.207, 0.487) (0.207, 0.487) - - - 10 (0.207, 0.487) (0.207, 0.487) - - - 20 (0.208, 0.488) (0.207, 0.487) - - - 30 (0.208, 0.488) (0.208, 0.488) - - - 40 (0.208, 0.488) (0.208, 0.488) - - - 50 (0.208, 0.488) (0.208, 0.488) - - - 60 (0.208, 0.488) (0.208, 0.488) - - - 70 (0.208, 0.488) (0.208, 0.488) - - - 80 (0.208, 0.488) I <= 10 % - - - - - - - - - Test procedure All measurements were performed in an environmentally controlled laboratory employing suitable baffling to minimize stray light. The sample was mounted in its normal operating orientation on a rotating mirror goniophotometer and operated from a stabilized supply. The photometric output was monitored and measurements were performed once stability was achieved. The goniophotometer was used to measure the spatial distribution of both luminous intensity and, in conjunction with a spectroradiometer, spectral irradiance. The distribution locus comprises points in the C0 and C90 planes at no more than 10º gamma intervals from 0. The CIE (x,y) coordinates and other derived metrics (CIE (u', v'), CCT and CRI) are calculated from the weighted sum (weighted for intensity and represented solid angle) of the measured spectral irradiances. Stabilization Time 1.75 hour Sample Orientation Horizontal Total Operation Time 2.50 hour Equipment and uncertainties LightLab International R80A C-gamma rotating mirror goniophotometer with a test distance of 8 m. Luminous Intensity ± 4 % Temperature ± 1 C Luminous Flux ± 4 % Luminous Efficacy ± 4.5 % Horizontal, Vertical Angles ± 0.25º ± PhotoResearch PR-670 spectroradiometer (380-780 nm., 2 nm. per pixel) measuring at a distance from the sample deemed greater than five times the maximum observed luminous opening dimension. CIE (x, y) coordinates ± 0.002 CCT ± 100 K CIE (u', v') coordinates ± 0.003 Ra ± 3 (u', v') Color difference ± 0.001 Scotopic / Photopic Ratio * ± 0.02 Relative Spectral Irradiance * ± 2 % R9 * ± 3 Yokogawa WT210 power meter connected in circuit to the sample electrical supply Voltage ± 0.5 % Frequency * ± 0.1 Hz Current ± 0.5 % Power ± 0.5 % Current THD * ± 3 % Power Factor ± 0.02 This report contains data that are not covered by the NVLAP accreditation. Quantities marked with * are not covered. IESNA LM-79-08 Calculator v4.6 (20th Aug 2013) Page 5 of 8 ES

Legend: C0-Solid, C45-Dashed, C90-Grey (cd) INTENSITY SUMMARY (cd) C-Plane Flux Gamma C0 C22.5 C45 C67.5 C90 (lm) 90 0.0 1194 1194 1194 1194 1194 5.0 1191 1221 1226 1188 1189 115 10.0 1173 1205 1209 1170 1170 15.0 1147 1176 1179 1138 1138 327 20.0 1107 1136 1139 1097 1095 25.0 1061 1085 1086 1045 1043 491 400 30.0 1001 1024 1022 983 981 35.0 932 954 951 912 909 584 60 40.0 855 875 871 835 831 45.0 771 790 784 750 748 594 50.0 684 698 694 663 661 55.0 590 603 598 572 569 526 800 60.0 494 505 501 478 476 65.0 396 405 402 383 381 391 70.0 298 305 302 288 286 75.0 201 206 204 194 192 212 80.0 111 113 112 106 104 85.0 38 39 38 35 33 47 30 90.0 0 0 0 0 0 1200 (Two plane symmetry) C0-C90 ZONAL FLUX AND PERCENTAGES AVERAGE LUMINANCE (cd / sq.m) Zone Flux (lm) % Lamp % Luminaire Gamma C0 C45 C90 0-30 933 N / A 28.4 45.0 4320 4393 4191 0-40 1517 N / A 46.2 55.0 4073 4132 3927 0-60 2637 N / A 80.2 65.0 3714 3770 3574 0-90 3287 N / A 100.0 75.0 3077 3125 2943 40-90 1770 N / A 53.8 85.0 1741 1742 1477 60-90 650 N / A 19.8 90-180 0 N / A 0.0 0-180 3287 N / A 100.0 Total Light Output = 3287 lm BY: E. Southgate Date of test 20-Aug-2013 Authorized Signatory Date of report 23-Aug-2013 Page 6 of 8 ES

Intensity data (cd) C-Plane Gamma C0 C22.5 C45 C67.5 C90 0.0 1194 1194 1194 1194 1194 2.5 1194 1223 1213 1191 1193 5.0 1191 1221 1226 1188 1189 7.5 1182 1213 1220 1181 1179 10.0 1173 1205 1209 1170 1170 12.5 1161 1191 1196 1156 1156 15.0 1147 1176 1179 1138 1138 17.5 1129 1156 1159 1121 1120 20.0 1107 1136 1139 1097 1095 22.5 1084 1112 1114 1072 1070 25.0 1061 1085 1086 1045 1043 27.5 1031 1056 1056 1014 1012 30.0 1001 1024 1022 983 981 32.5 968 990 987 948 945 35.0 932 954 951 912 909 37.5 895 915 912 873 872 40.0 855 875 871 835 831 42.5 814 832 828 792 789 45.0 771 790 784 750 748 47.5 729 745 739 708 703 50.0 684 698 694 663 661 52.5 637 651 646 617 614 55.0 590 603 598 572 569 57.5 544 555 550 525 522 60.0 494 505 501 478 476 62.5 445 455 452 431 428 65.0 396 405 402 383 381 67.5 347 356 352 335 333 70.0 298 305 302 288 286 72.5 249 255 253 240 238 75.0 201 206 204 194 192 77.5 155 158 157 148 147 80.0 111 113 112 106 104 82.5 71 73 72 67 65 85.0 38 39 38 35 33 87.5 16 16 15 12 9 90.0 0 0 0 0 0 Page 7 of 8 ES

Test Distance: Test Temperature: Significance: 8.0 metres 24.8 degrees Celsius This laboratory has no control over the selection of samples to be tested. All testing is performed on the understanding that the significance of the report is limited to the extent that the test sample is representative of production units. Special Notes: The intensity values contained in this report are shown as tested. It should also be noted that prorating the lumen output for the use of other lamp/ballast combinations, or for use in different environmental conditions, than that tested may produce erroneous results. This report is free of erasures and corrections. Photometric intensity values are reported using the CIE Cgamma coordinate system as described in CIE Publication number 121. Testing Procedure: Tested in accordance with the applicable sections of N.A. IES Publication Number LM79-08. 23-Aug-13 10:31:48 REPORT program version: 3.80a Page 8 of 8 ES