Franck-Hertz Experiment in Neon/Hg

Similar documents
THE FRANCK-HERTZ EXPERIMENT

University of Massachusetts, Amherst

Physics 201: Experiment #1 Franck-Hertz Experiment

Franck-Hertz Experiment

EXPERIMENT #5 The Franck-Hertz Experiment: Electron Collisions with Mercury

The Franck-Hertz Experiment Physics 2150 Experiment No. 9 University of Colorado

Physics 476LW. Advanced Physics Laboratory - Franck Hertz

Franck-Hertz Experiment

Franck-Hertz experiment using Neon tube

Experiment 6: Franck Hertz Experiment v1.3

Physics 248, Spring 2009 Lab 9: Franck-Hertz Experiment

The Franck-Hertz Experiment

EXPERIMENT 15. The Frank Hertz Experiment. 1. Pre-Laboratory Work [2 pts] Lab section: Partner's name(s): Grade:

EXPERIMENT 14. The Franck-Hertz Experiment. E 1 E 2 = hf (1)

Franck-Hertz Experiment

THE FRANCK-HERTZ EXPERIMENT

FRANCK-HERTZ EXPERIMENT ===========================

THE FRANCK-HERTZ EXPERIMENT

EXPERIMENT 5. The Franck-Hertz Experiment (Critical Potentials) Introduction

The Franck-Hertz Experiment

KE = 1 2 mv2 = ev. (1)

Laboratory #12: Franck-Hertz Experiment: Electron Spectroscopy

Determining the excitation energies of mercury and neon using Franck-Hertz tubes

The Franck-Hertz Experiment

Finding e/m. Purpose. The purpose of this lab is to determine the charge to mass ratio of the electron. Equipment

Ratio of Charge to Mass (e/m) for the Electron

The Franck-Hertz Experiment David Ward The College of Charleston Phys 370/Experimental Physics Spring 1997

Electric Deflection of Electrons

Investigation #8 INTRODUCTION TO QUANTUM PHENONEMA

This lab was adapted from Kwantlen University College s Determination of e/m lab.

Experiment 2 Deflection of Electrons

Experiment objectives: measure the ratio of Planck s constant to the electron charge h/e using the photoelectric effect.

Lab 1: Determination of e/m for the electron

Investigation #9 OBSERVATION OF THE PHOTOELECTRIC EFFECT

Measurement of Charge-to-Mass (e/m) Ratio for the Electron

The Photoelectric Effect and the Quantization of Light

THE CHARGE-TO-MASS RATIO OF THE ELECTRON (e/m)

Thermionic emission and Frank-Hertz oscillations

Charge to Mass Ratio of The Electron

e/m APPARATUS Instruction Manual and Experiment Guide for the PASCO scientific Model SE D 5/ PASCO scientific $5.

Experimental Physics I & II "Junior Lab" Fall Spring 2008

Experiment 2-7. Planck constant measurement. using photoelectric effect

[2] (b) An electron is accelerated from rest through a potential difference of 300 V.

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

h/e Apparatus h/e Apparatus Accessory Kit

203-NYC-05: Waves, Optics & Modern Physics

The Franck Hertz Experiment and the Ramsauer Townsend Effect: Elastic and Inelastic Scattering of Electrons by Atoms

ELECTROMAGNETIC WAVES

PhysicsAndMathsTutor.com 1

ACTIVITY 1. Exploring Light from Gases

Physics 1CL OPTICAL SPECTROSCOPY Spring 2010

Name the region of the electromagnetic radiation emitted by the laser. ...

Dual Nature of Radiation and Matter-I

Discovered by German scientist Johann Hittorf in 1869 and in 1876 named by Eugen Goldstein.

Diffraction of Electrons

EXPERIMENT 2-6. e/m OF THE ELECTRON GENERAL DISCUSSION

Photoelectric Effect

EXPERIMENT 18 THE PHOTOELECTRIC EFFECT

Rb, which had been compressed to a density of 1013

Charge to Mass Ratio of The Electron

Atomic Emission Spectra

The Photoelectric E ect

Sparks in Gases: Line Spectra

high energy state for the electron in the atom low energy state for the electron in the atom

ATOMIC WORLD P.1. ejected photoelectrons. current amplifier. photomultiplier tube (PMT)

Physics 1C OPTICAL SPECTROSCOPY Rev. 2-AH. Introduction

Lasers... the optical cavity

Observation of Atomic Spectra

Laboratory Exercise. Quantum Mechanics

Electron Diffraction

which is deemed to be defective in material or workmanship.

Quantum physics practice question answers

Lab 5 - ELECTRON CHARGE-TO-MASS RATIO

Radiation - Electromagnetic Waves (EMR): wave consisting of oscillating electric and magnetic fields that move at the speed of light through space.

Experiment V Motion of electrons in magnetic field and measurement of e/m

CSUS Department of Chemistry Experiment 9 Chem. 1A

Copyright 2008, University of Chicago, Department of Physics. Experiment VI. Gamma Ray Spectroscopy

Introduction to light Light is a form of energy called electromagnetic radiation. A chart of the electromagnetic spectrum is shown below.

Laboratory Atomic Emission Spectrum

Line Spectra. 6 The line spectrum of hydrogen includes no X-ray frequencies because

Experiment 24: Spectroscopy

Background The power radiated by a black body of temperature T, is given by the Stefan-Boltzmann Law

LC-4: Photoelectric Effect

ATOMIC PHYSICS PHOTOELECTRIC EFFECT Practical 2 DETERMINATION OF PLANCK S CONSTANT BY MEANS OF THE STOPPING POTENTIAL

Emission of Light: Discharge Lamps & Flame Tests 1

Lab 5 - ELECTRON CHARGE-TO-MASS RATIO

Ruby crystals and the first laser A spectroscopy experiment

Analysis of γ spectrum

The Measurement of e/m

Fingerprinting the Stars Lab

MAGNETIC DEFLECTION. OBJECTIVE: To observe the effect of a magnetic field on an electron beam. To measure the Earth s magnetic field.

Chapters 28 and 29: Quantum Physics and Atoms Solutions

Physical Structure of Matter

SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION

Determination of Planck s constant and work function of metals using photoelectric effect

MAGNETIC DEFLECTION. OBJECTIVE: To observe the effect of a magnetic field on an electron beam. To measure the Earth s magnetic field.

M2 TP. Low-Energy Electron Diffraction (LEED)

Photoelectric Effect

1 The Cathode Rays experiment is associated. with: Millikan A B. Thomson. Townsend. Plank Compton

The Franck-Hertz Experiment

Transcription:

Franck-Hertz Experiment in Neon/Hg Equipment Franck-Hertz tube (Ne or Hg) & Operating Unit Analog oscilloscope Many Banana cables; 1 BNC cables; 2 BNC-Banana Plug connector Graphing paper Theory This experiment will demonstrate the 1926 Nobel Prize Winning Franck-Hertz Experiment. The existence of discrete energy levels in atoms is demonstrated by the Franck-Hertz experiment. An anode and cathode are placed in a tube which contains Neon/Hg gas. Electrons emitted from the cathode are accelerated toward the grid and thus their kinetic energy increases linearly with distance. Two collision processes happen in tube. Firstly, the electrons suffer elastic collisions with the neon atoms; these are collisions in which the sum of the kinetic energies of the electron and of the gas atoms is conserved. In such collisions, the electron loses a very small fraction of its energy. Therefore the electron has a kinetic energy approximately equal to ev, where V is the potential difference between grid and cathode. The small retarding voltage (~0.5 V) does not prevent them from being collected at the anode, provided that V > 0.5 V. If, on the other hand, an electron suffers an inelastic collision with a gas atom in which it lost nearly all its energy, it will be turned around by the retarding field between the grid and node and will not participate in the anode current I. As the voltage difference between the cathode and grid is increased, the anode current increases until a critical voltage is reached, at which point the current decreases sharply. We interpret this decrease to be the result of inelastic collisions that evidently occur as soon as the electron kinetic energy K reaches a threshold energy. An electron with this KE loses all its energy to an atom, exciting an electron in the atom from one discrete energy level to a higher one. The result is a dip in the anode current. As the voltage is further increased to 0.5 V + the exciting potential, an electron has sufficient energy to overcome the retarding voltage, even after making on inelastic collision. When V becomes 2 x (exciting potential), an electron can make two inelastic collisions, and another dip in the anode current curve occurs. By measuring the distance between "dips" we can measure the critical potential to excite an electron in the neon atom. Another important result from this experiment is the light of a corresponding wavelength is observed to come from the tube as soon as V becomes greater than the exciting potential. Evidently, when an electron in a neon atom is excited to an energy level above its normal energy level, it returns to its normal state by radiating light. The concepts of quantum theory are verified as several well-defined minima can be observed on your oscilloscope screen, as the electrode current produced by the control unit excites the neon resonance line. The apparatus consists of a neon-filled (Hg-filled) Franck-Hertz tube in a housing; a control unit with power supplies, reverse voltage source and DC preamplifier; and a shielded cable with BNC connectors. 1

Experimental Set-up If using the Hg tube, turn the heating oven on the side panel of tube to 150-200 C. WARNING: the Hg tube gets very hot!!! The indirectly heated cathode (green knob) requires a warm-up time of about 90 seconds after you switch on the operating unit for the Ne/Hg tube. Connect the color coded outputs of the operating unit with the color coded inputs of the Ne / Hg tube. Connect the FH signal (M) from the tube with a BNC cable to operating unit. Connection to oscilloscope: BNC-Bananan Plug adapter: RED is signal input; BLACK is ground. X-axis, signal Channel 1: from Va/10 on Ne unit or U B /10 on Hg unit Y-axis, signal Channel 2: From (V+) on Ne unit or FH signal y-out on Hg unit; From ground of operating unit to ground of Channel 2 and Channel 1. Oscilloscope settings: Time: X-Y axis Channel 1& 2 on DC mode Adjust Volts/Div so that the graph fills the screen (see figure 2). Procedure 1: Set switch to Ramp position Increase the acceleration voltage (starting from 0 volts), while reducing the "gain" setting, to keep the output reading within the meter range. Adjust the heater for the filament ( = electron flux) for optimum results. A current on the order of 10nA then flows from the collector electrode to the anode. Amplification gain (on the operating unit) or current sensitivity (on the measurement amplifier) should then be set to suitable levels. Quantitatively sketch the graph from the oscilloscope on graphing paper. Include the grid lines; label the axis; importantly: provide the correct scale for the x-axis; From the graph and using the x-scale, determine the ionization potential for Ne / Hg. Procedure 2: Switch to manual for the acceleration voltage on the operating unit. Darken room Slowly turn the acceleration voltage to medium Observe the tube and adjust the heating current for optimal results. Vary acceleration voltage Take note of your observations as the voltage varies. CAUTION: KEEP THESE CRITERIA IN MIND The collector electrode is negative with respect to the anode; be sure that the polarity of any indicators on the measurement amplifier are correct. The emission current in the tube and therefore the collector current are influenced by the heating current. The heating current must be set (appropriate level when the bias is within the 2

range 6-8 V) so that no independent discharge occurs at an acceleration of 70 V (recognizable by red light between the cathode and control grid). A limiting resistor (kw) at the anode terminal of the tube prevents overloading. Even if an impact ionization discharge occurs in the tube as a result of excessive voltage, the tube will not be damaged. The countervoltage between anode and collector electrode should be set between 6 and 10 V so that the minima (maximum number = 3) in the current/voltage curve are clearly recognizable. If the countervoltage is too high, a decreasing characteristic line occurs in some cases with negative collector current. If the acceleration voltage is slowly raised from an initial value of zero, a reduction in collector current occurs starting at about 20 V. This is accompanied by the appearance of a glowing red layer at the anode. As the anode voltage is raised further, the collector current decreases and the glow movers toward the cathode. The collector current reaches a minimum when the glowing layer detaches from the anode. As the anode voltage is raised, a dark zone appears, followed by a second glowing layer (at about 40 V). In all, a maximum of two dark zones may be observed (layered positive column). These layers are created as follows: Electrons emerging from the cathode begin their trajectory at a velocity close to zero, and are all accelerated by the same field, meaning that they also all reach the energy necessary for excitation in the same cross section. Excitation therefore occurs in a layer. In the process, however, all of the electrons lose their energy, begin again with a velocity close to zero, and so on. The layers naturally become blurred after a series of such cycles due to immediate statistical scattering of the excitation sites, and the column gradually becomes homogeneous again. For exact evaluations of the current/voltage relationship the iron/barium contact potential of 2.5V must be subtracted from the acceleration voltage value. The voltage difference between the first and second maximum indicates which excited state the electron is excited to. You will find that this value is consistent with the energy diagram for neon. The transitions between these two groups of excited states lie in the visible region, and are responsible for the appearance of glowing layers. This light is accessible to spectroscopic evaluation, and contains several strong spectral lines in the yellow and red regions. The transitions to the ground state lie in the far ultraviolet, and therefore cannot be studied. For Your Labreport: An introduction including theory and relevant formulas for this lab and description of the experiment. A sketch of the experimental set-up and the cable connections to the oscilloscope. The procedure for the experiment including an explanation of why you perform each task The oscilloscope s graph for Hg / Ne onto graph paper; label axis with correct units, zero level for x-axis, and the correct scale for x-axis. Include the ionizaton energy for Hg / Ne and how you derived that value. Describe the observations from procedure 2 and include an explanation in your own words using theory as to why you observed this occurance. Questions: 3

Explain in words what is plotted on your graph / oscilloscope? Why does the Franck- Hertz signal (FH signal) shows dips for certain accelation voltages? Lets assume the distance between cathode and control grid is 1 cm, and the distance between contral grid and anode is 0.25cm. A) Draw a sketch of the electrical potential as a function of distance for an acceleration voltage of 20V and a reverse bias of 2V. B) Draw a sketch of the kinetic energy of an electron as a function of distance in the above potential, as it undergoes inelastic collision with the gas (Ne/Hg). Why do you see light from the Neon / Hg tube? How is it created. Explain. Why does the light from the tube has a vertical pattern? Conclusion: Write a short conclusion mentioning your result and discussing possible sources or error. Add comments and remarks regarding the lab and its write-up for improvement. 4

5