Progress in the development of large-area submillimeter-resolution CdZnTe strip detectors

Similar documents
Development of CZT strip detector modules for to 1-MeV gamma-ray imaging and spectroscopy

THE spectroscopic performance of large volume CdZnTe

Energy and position resolution of a CdZnTe gamma-ray detector with orthogonal coplanar anodes

arxiv:astro-ph/ v1 6 Mar 2001

Measurement of material uniformity using 3-D position sensitive CdZnTe gamma-ray spectrometers

Final report on DOE project number DE-FG07-99ID High Pressure Xenon Gamma-Ray Spectrometers for Field Use

PERFORMANCE IMPROVEMENT OF CZT DETECTORS BY LINE ELECTRODE GEOMETRY

Efficiency and Attenuation in CdTe Detectors

Position Sensitive Germanium Detectors for the Advanced Compton Telescope

Investigation of the Asymmetric Characteristics and Temperature Effects of CdZnTe Detectors

GRAPE A Balloon-Borne Gamma-Ray Polarimeter

Estimate of Large CZT Detector Absolute Efficiency

arxiv:astro-ph/ v1 26 Sep 2003

Nuclear Instruments and Methods in Physics Research A

Stability and Characteristics of Large CZT Coplanar Electrode Detectors

SENSITIVITY ANALYSIS TO EVALUATE THE TRANSPORT PROPERTIES OF CdZnTe DETECTORS USING ALPHA PARTICLES AND LOW-ENERGY GAMMA-RAYS

Development of a Dedicated Hard X-Ray Polarimeter Mark L. McConnell, James R. Ledoux, John R. Macri, and James M. Ryan

Cadmium Zinc Telluride (CZT) Detectors

Development and characterization of 3D semiconductor X-rays detectors for medical imaging

arxiv:astro-ph/ v1 13 Oct 1999

Development of High-Z Semiconductor Detectors and Their Applications to X-ray/gamma-ray Astronomy

New perspectives in X-ray detection of concealed illicit materials brought by CdTe/CdZnTe spectrometric detectors

New trends in CdTe detectors for X and γ-ray applications

A search for gamma-ray flares from black-hole candidates on time scales of 1.5 hours

arxiv:astro-ph/ v1 18 Aug 2000

Polaris 3-D CdZnTe (CZT) Gamma-Ray Imaging Spectrometers

Development of a Hard X-Ray Polarimeter for Solar Flares and Gamma-Ray Bursts

X- & γ-ray Instrumentation

Stand-off Nuclear Radiation Detection

Development of Gamma-ray Monitor using CdZnTe Semiconductor Detector

Fast Neutron and Gamma-Ray Detectors for the CSIRO Air Cargo Scanner

PoS(Extremesky 2011)067

PoS(TIPP2014)033. Upgrade of MEG Liquid Xenon Calorimeter. Ryu SAWADA. ICEPP, the University of Tokyo

Tracking and imaging gamma ray experiment (TIGRE) for 1 to 100 MEV gamma ray astronomy

Development of a Spectral Model Based on Charge Transport for the Swift/BAT 32K CdZnTe Detector Array

A Concept of Cylindrical Compton Camera for SPECT

Advances in Compound Semiconductor Radiation Detectors. a review of recent progress

COMPTEL observations of Cygnus X 1

A Radiation Monitoring System With Capability of Gamma Imaging and Estimation of Exposure Dose Rate

Nuclear Instruments and Methods in Physics Research A

Compton Imaging with Coincidence Measurements for Treaty Verification Purposes

arxiv: v1 [physics.ins-det] 29 Jun 2011

Maximum-Likelihood Deconvolution in the Spatial and Spatial-Energy Domain for Events With Any Number of Interactions

Development of New MicroStrip Gas Chambers for X-ray Applications

Compton Camera. Compton Camera

On the development of compound semi-conductor thallium bromide detectors for astrophysics

Detectors for High Resolution Gamma-ray Imaging Based on a Single CsI(Tl) Scintillator Coupled to an Array of Silicon Drift Detectors

COMPTON imaging is an attractive technology used in

Detector and Telescope Development for ProtoEXIST and Fine Beam Measurements of Spectral Response of CZT Detectors

Hard X- and g-ray measurements with a large volume coplanar grid CdZnTe detector

SCI-O11. Design of a Compton Spectrometer Experiment for Studying Electron Response of a Scintillator

High-Resolution Gamma-Ray and Neutron Detectors For Nuclear Spectroscopy

A Study On Radioactive Source Imaging By Using A Pixelated CdTe Radiation Detector

EEE4106Z Radiation Interactions & Detection

A dual scintillator - dual silicon photodiode detector module for intraoperative gamma\beta probe and portable anti-compton spectrometer

Light ion recoil detector

Readout of LYSO using a new silicon photodetector for positron emission tomography

Performance of high pressure Xe/TMA in GEMs for neutron and X-ray detection

Spectrometric Performances of CdTe and CdZnTe Semiconductor Detector Arrays at High X-ray Flux

Spectra of a recent bright burst measured by CGRO-COMPTEL: GRB

Radiation Detection for the Beta- Delayed Alpha and Gamma Decay of 20 Na. Ellen Simmons

Neutron Induced Nuclear Counter Effect in Hamamatsu Silicon APDs and PIN Diodes

Development of semiconductor imaging detectors for a Si/CdTe Compton camera

Silicon Drift Detectors for gamma-ray detection: 15 years of research (and collaboration between Politecnico and INAF-Milano)

An Interdigitated Pixel PIN Detector for Energetic Particle Spectroscopy in Space

Deposited on: 20 December 2010

CASTER A Scintillator-Based Black Hole Finder Probe

CADMIUM telluride (CdTe) and cadmium zinc telluride

Development of a Radioxenon Detection System Using CdZnTe, Array of SiPMs, and a Plastic Scintillator

Performance of the Gamma-ray Imaging Detector with Micro-TPC

GEM-based photon detector for RICH applications

Advances in the Micro-Hole & Strip Plate gaseous detector

1. Introduction. Study of Thick CZT Detectors for X-ray and Gamma-Ray Astronomy

& SUN ZhiJia 1;2. Abstract

WM2013 Conference, February 24 28, 2013, Phoenix, Arizona, USA

A POSITION SENSITIVE ALPHA PARTICLE DETECTOR BASED ON A LYSO CRYSTAL AND A MICRO-PIXEL AVALANCHE PHOTODIODE

Background and Sensitivity Simulation of a Space Based Germanium Compton Telescope

X-ray spectrometry with Peltier-cooled large area avalanche photodiodes

Kirkpatrick-Baez optics for the Generation-X mission

High-Sensitivity Gamma-Ray Imaging With Double Sided Strip Detectors

THE mobility-lifetime product (μτ) is used to characterize

Figure 1. Decay Scheme for 60Co

Position sensitive detection of thermal neutrons with solid state detectors (Gd Si planar detectors)

A Measurement of Monoenergetic Neutrons from 9 Be(p,n) 9 B

Results of a Si/CdTe Compton Telescope

arxiv: v2 [physics.ins-det] 8 Feb 2013

Nuclear Physics and imaging in Medical, Security and Environmental applications

High Purity Germanium Detector Calibration at ISOLDE

Development of a new MeV gamma-ray camera

1 Introduction STATUS OF THE GLAST LARGE AREA TELESCOPE. SLAC-PUB December Richard Dubois. Abstract

1420 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 57, NO. 3, JUNE /$ IEEE

PHOTOELECTRON COLLECTION EFFICIENCY AT HIGH PRESSURE FOR A GAMMA DETECTOR ENVISAGING MEDICAL IMAGING

A NEW GENERATION OF GAMMA-RAY TELESCOPE

Scintillator gamma-ray detectors with silicon photomultiplier readouts for high-energy astronomy

Using BATSE to Measure. Gamma-Ray Burst Polarization. M. McConnell, D. Forrest, W.T. Vestrand and M. Finger y

Application Note ANCZT-2 Rev. 3 Charge Trapping in XR-100T-CdTe and -CZT Detectors

ONE of the most noticeable facts in the field of room

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN

Boron-based semiconductor solids as thermal neutron detectors

ISPA-Tubes with YAP:Ce Active Windows for X and Gamma Ray Imaging.

Transcription:

University of New Hampshire University of New Hampshire Scholars' Repository Space Science Center Institute for the Study of Earth, Oceans, and Space (EOS) 7-19-1996 Progress in the development of large-area submillimeter-resolution CdZnTe strip detectors John R. Macri University of New Hampshire - Main Campus, John.Macri@unh.edu V Boykin University of New Hampshire - Main Campus K Larson University of New Hampshire - Main Campus M Mayer University of New Hampshire - Main Campus Mark L. McConnell University of New Hampshire - Main Campus, mark.mcconnell@unh.edu See next page for additional authors Follow this and additional works at: https://scholars.unh.edu/ssc Recommended Citation John R. Macri ; Valerie Boykin ; Kipp Larson ; Michelle Mayer ; Mark L. McConnell ; James M. Ryan ; Michael L. Cherry ; T. Gregory Guzik ; Boris A. Apotovsky ; Jack F. Butler ; F. P. Doty and Clinton L. Lingren "Progress in the development of large-area submillimeter-resolution CdZnTe strip detectors", Proc. SPIE 2859, Hard X-Ray/Gamma-Ray and Neutron Optics, Sensors, and Applications, 29 ( July 19, 1996); doi:10.1117/12.245150; http://dx.doi.org/10.1117/12.245150 This Conference Proceeding is brought to you for free and open access by the Institute for the Study of Earth, Oceans, and Space (EOS) at University of New Hampshire Scholars' Repository. It has been accepted for inclusion in Space Science Center by an authorized administrator of University of New Hampshire Scholars' Repository. For more information, please contact nicole.hentz@unh.edu.

Progress in the development of large-area submillimeter-resolution CdZnTe strip detectors Rights (1996) COPYRIGHT SPIE--The International Society for Optical Engineering. Authors John R. Macri, V Boykin, K Larson, M Mayer, Mark L. McConnell, James M. Ryan, M L. Cherry, T G. Guzik, Boris A. Apotovsky, J F. Butler, F P. Doty, and C L. Lingren This conference proceeding is available at University of New Hampshire Scholars' Repository: https://scholars.unh.edu/ssc/103

Progress in the development of large area sub-millimeter resolution CdZnTe strip detectors J.R. Macri, D.V. Boykin, K. Larson, M. Mayer, M.L. McConnell, J.M. Ryan Space Science Center, University of New Hampshire Durham, NH M.L. Cherry, T.G. Guzik Department of Physics and Astronomy, Louisiana State University Baton Rouge, LA B.A. Apotovsky, J.F. Butler, F.P. Doty, C.L. Lingren DIGIRAD, San Diego, CA ABSTRACT We report progress in ongoing measurements of the performance of a sub-millimeter pitch CdZnTe strip detector developed as a prototype for astronomical instruments. Strip detectors can be used to provide twodimensional position resolution with fewer electronic channels than pixellated arrays. Arrays of this type are under development for the position-sensitive image plane detector for a coded-aperture telescope operating in the hard x-ray range of 20-200 kev. The prototype is a 1.5 mm thick, 64 x 64 orthogonal stripe CdZnTe detector of 0.375 mm pitch in both dimensions, approximately one square inch of sensitive area. In addition to energy and spatial resolution capabilities, as reported last year, we demonstrate the imaging capabilities and discuss uniformity of response across an 8 x 8 stripe, 64 "pixel", segment of detector. A technique for determination of the depth of photon interaction is discussed and initial results related to depth determination are presented. Issues related to the design and development of readout electronics, the packaging and production of strip detectors and the production of compact strip detector modules, including detector and readout electronics, are also discussed. Keywords: CdZnTe, CZT, strip detector, x-ray astronomy, gamma-ray astronomy, imaging 1. INTRODUCTION The next step in the development of hard x-ray telescopes for astronomical imaging will require improvements both in angular resolution and in energy 1,2 A common approach to imaging at these energies involves coded aperture imaging techniques, where the angular resolution depends directly on the spatial resolution of the detector plane.3 Imaging detectors constructed of CdZnTe4, a high density, high atomic number material with a large band gap permitting room temperature detector operation, represent a strong candidate technology for achieving both improved angular and energy resolution. We have developed a concept for a new instrument, MARGIE (Minute-of-Arc Resolution Gamma Imaging Experiment), that will be capable of imaging with good energy and arc-minute angular resolution both steady-state and transient sources of cosmic gamma rays.1 Initially, this is intended to be flown as a balloon payload. Eventually, however, this design could be employed on an orbiting platform. Motivated by the MARGIE concept and by encouraged by recent demonstrations of CdZnTe imaging detectors,5'6'7'8'9 we have continued to pursue the development of CdZnTe arrays for astronomical imaging. 0819422479/96/$6.00 SPIE Vol. 2859/29

Figure 1 is a photograph of the prototype strip detector manufactured by DIGIRAD of San Diego, CA. It consists of a monolithic CdØ9Zn0 i Te substrate measuring 28 x 28 mm by 1.5 mm thick with 64 gold stripe contacts and 2 guard stripes on each surface. The stripe pitch and thus pixel definition is 0.375 mm in both dimensions, with an effective imaging area of 576 mm2. The CdZnTe array is mounted in a printed circuit board carrier with contacts to all stripes in a standard pin grid array pattern to facilitate safe handling and testing. 3. STRIP DETECTOR OPERATING PRINCIPLES Fig. 2 shows a schematic diagram of a small portion of the strip detector to illustrate the operational principles for the determinations Figure 1. of photon interaction site and energy deposit Photograph of prototype CdZnTe strip detector An incident gamma photon interacts at a point within the strip detector generating an ionization charge region whose extent is determined by the resulting scattering and fluorescence processes. Calculations and measurements with CZT pixel detectors at the University of Arizona have determined the extent of this ionization site to be 2OO i Charge signals in proportion to the deposited energy and related to the transport of these ionization charges (electrons and holes) are detected on each surface on the contact stripes near the photon interaction site. The electrons, transported along the Z dimension by the bias field, are collected on the nearest anode stripes. Except for interactions occurring at the cathode surface, the holes, with relatively poor charge transport properties, are not fully collected during the amplifier's integration 1 1 Rather, signals are induced on the individual cathode stripe contacts stripes in relation to the distance from 1, 64 each surface the stripe and the amount of hole ' 0.375 mm pitch transport that takes place during the amplifier's integration time. Our measurements show that the size (pulse height) of this hole signal relative to the electron signal depends on the depth of the photon's interaction. 2. PROTOTYPE STRIP DETECTOR z > n-i Xn U) 0 ci) a- U) 4J a) ci) The stripe IDs and pulse heights of coincident X-Y signals define the photon interaction location in the X and Y dimensions. The Z dimension is determined for each event by anode(-i-) JIyYn+i Yn-i Figure 2. Strip detector operational principles. a- 30 / SPIE Vol. 2859

measuring the relative X and Y pulse heights. A photon interaction site far from the cathode surface results in relatively lower cathode pulse height than is observed when the interaction site is close to the cathode. As with pixel detectors, pulse height analysis of the anode signals provides the optimum energy measurement. 4. TEST SETUP Figure 3 illustrates the laboratory setup for the prototype strip detector tests. All stripes on each detector surface are biased to assure a uniform electric field in the CdZnTe. All untested stripes are ac coupled to ground. Eight consecutive contact stripes on each surface (Xl through X8 and Yl through Y8) are selected and ac coupled to signal processing channels. This defines an 8 x 8 stripe, 64 "pixel", region of the prototype detector for study. Each channel utilizes an Amptek A225 charge sensitive preamplifier/shaper which provides both fast and slow (2.5 jisec.) shaped outputs. Inverters and additional amplifiers are employedon the printed circuit board as required by the external NIM discriminators and CAMAC ADCs. Each fast channel (200 n.sec. shaping) has its own level discriminator, each slow channel its own peak sensing ADC. Any combination of X-discriminators firing in coincidence with any combination of Y-discriminators providesa strobe to the block of ADCs. Sixteen pulse heights are recorded for each registered event. The detector, its ZIF socket and the sixteen amplifier channels are mounted on printed circuit board enclosed in an aluminum box. The active area of the detector is open to illumination from either surface through thin windows in the aluminum box and holes in the ZIF socket and the printed circuit board. All measurements were performed at room temperature. LU LU LU LU HO Figure 3. Test setup. 8 x 8 stripe, 64 "pixel", region of strip detector 5.1 Spectroscopy and uniformity 5. PERFORMANCE It was previously demonstrated that signal charge for each detected event is sharedby the triggering anode stripe and one, not more, of its neighbors.8 That result highlighted the importance of summing the signals from neighboring anode stripes when measuring the totalenergy deposit. Figure 4 illustrates this advantage with a comparison between trigger-channel-only and trigger-plus-neighboring-channel pulse height data. Figure 4a shows the response of a single "pixel" to 122 key photons from a 57Co source. Figure 4b shows the distribution of these same events when the pulse heights of the two adjacent anodes (Yl and Y3) are added. SPIE Vol. 2859/31

Figure 4. Response: single "pixel" 80 80 70 70 60 60 50 50 40 30 30 20 20 10 10 0 0 Y2 (CHANNELS) Yl + Y2 + Y3 (CHANNELS) Figure 4a. 57Co, 122 key. Trigger stripe (Y2) pulse height only. Single "pixel" defined by X2-Y2 coinc. Figures 5a and 5b illustrate the strip detector prototype. Figure 4b. 57Co, 122 key. Same events. Sum of pulse heights, trigger stripe plus adjacent stripes. uniformity of response across the 8 x 8 stripe, 64 "pixel", test region of our Figure 5. Response: 64 "pixel", 8 x 8 stripe region. Flood illumination 200 300 175 150 250 125 200 100 150 75 100 50 25 50 0 Y SUM CHANNELS Y SUM CHANNELS Figure 5a. 241Am, 60 key. Sum of 64 "pixels". Figure 5b. 57Co, 122 key. Sum of 64 "pixels". 32 / SPIE Vol. 2859

The detector was flood illuminated with 60 kev photons from 241Am (Figure 5a) and 122 kev photons from 57Co (Figure 5b). The response of the detector pixels is sufficiently uniform that the pulse height spectra accumulated by adding the contribution from all 64 pixels show clear full-energy peaks. Note that the responses of the individual amplifier channels were matched with a test pulse input and that no additional effort has been made in these examples to match photopeak peak pulse heights from the individual pixels before the sum histogram was computed. As with the single pixel example above (Figure 4), summing the signals collected for each event enhances the population of the photopeak and provides the better total energy measurement. The energy resolution is, however, degraded in this test since noise from all amplifier channels is present. 5.2 Imaging A collimated beam of photons from a 57Co source was directed at different locations across the 8 x 8 stripe test region of the strip detector. The beam spot size, determined by collimator geometry, is -O.25 mm. The images in Figure 6 show the number of events located at each of the 64 "pixels" for two pointings of the collimator. Each event is located at the intersecting coordinates of the X and Y stripe recording the highest pulse height. In both cases a single "pixel" corresponding to the beam spot position registers the maximum number of events. The nature of the wing distributions which move along with the beam spot in these images is not yet understood. Recall, stripe pitch, and thus "pixel" size, is 0.375 mm in both the X and Y dimensions. 100 80 120-60- 40-20 0- Figure 6. Images of 0.25 mm 57Co beam spot at two locations within the 8 x 8 stripe test region. Stripe pitch, "pixel" size, is 0.375 mm in each dimension. SPIE Vol. 2859 /33

5.3 Interaction depth As described above in the discussion of strip detector operational principles (section 3), the strength of the hole transport signal measured on neighboring cathode stripes is related to the depth of interaction, the Z- coordinate. Figure 7 illustrates the pulse height relationship between cathode (X-dimension, hole) signals and anode (Y-dimension, electron) signals for 16OO detected events from 122 key photons incident from a 57Co source. The mean free path of these photons in CZT, 1.7 mm, assures that interactions take place at all depths within the detector. The flat distribution of pulse heights for photopeak events in the Y-dimension is evidence of CZT's good electron transport properties. The broad distribution of pulse heights for these same events in the X-dimension is evidence of widely varying cathode signal strength related to the depth of the interaction and the relatively poor transport of holes as predicted by the strip detector 1 1 Events with small relative x pulse height interacted farther from the cathode surface than those with larger relative X pulse height. To further demonstrate this effect we illuminated our prototype from opposite sides with 60 kevphotons from an 24 1 Am source. The mean free path of these photons in CZT, 0.26 mm, assures that most interactions take place nearer the incident surface the detector. As predicted, the average cathode (X-dimension, holes) pulse height was higher (28% higher in our measurements) for the case where the detector was illuminated from the cathode side than when illuminated from the anode side. 600.o 400 - a) > 200-0. 0 I. i I. i. I i I 250 500 750 1000 Sum-X (Pulse Height). I 5 10 15 20 25 30 Counts Figure 7. Distribution of X-dimension (cathode, holes) and Y-dimension (anode, electrons) pulseheight sums for 1 22 kev photon events in our prototype CZT strip detector. The relative pulse height recorded for each event is a measure of the depth of interaction, the Z-dimension). 6. READ-OUT CIRCUIT ISSUES As described previously, the strip detector contact geometry requires far fewer signalprocessing channels than does a pixellated array of the same pitch (128 vs. 4096 in this case).8 Event-triggered-processing facilitates recognition of the required X-Y coincidence, precise timing of the detection and the determination of relative timing with external events. For each detected event, only the pulse heights and IDs of the triggered stripes 34 ISPIE Vol. 2859

and their neighbors need to be read out. Ideally each signal-processing channel should contain its own lownoise charge-sensitive preamplifier, discriminator and shaping amplifier and each detector in the image plane array should be controlled and read out by circuitry that occupies the same area or less. We have demonstrated that by applying a relative pulse height technique we can achieve the discrimination of deep and shallow interaction depth for each detected event. The advantage of this technique for depth determination over techniques requiring pulse shape discrimination is the relatively simple and lowpower implementation in the readout electronics. Only one analog channel is required per stripe and only low noise relatively slow analog circuits would be required. Timing and/or pulse shape correction techniques may, however, be applicable to depth determination in CZT strip detectors and should also be studied. 12,13 7. FUTURE WORK Finer imaging demonstrations and the evaluation of the uniformity ofresponse across larger areas of the detector are important areas for study. Radiometry measurements are important for understanding the efficiency of the strip detector operating in the X-Y coincidence mode. Further characterization of the CZT strip detector signals and the optimization of the detector electronics for processing these signals is in progress. The goals of this effort are to fully understand the operational requirements and define appropriate detector and electronics specifications for developing compact modules that include the strip detector and signal processing electronics with appropriate analog, timing and digital functions. 8. CONCLUSIONS The performance capabilities of CdZnTe strip detectors are well suited to applications in gamma-ray imaging spectrometers. They have good energy and spatial resolution as demonstrated with conventional laboratory electronics. Good energy response with clear photopeaks in the targetenergy range and spatial resolution in two dimensions comparable to the stripe pitch (=0.375 mm) have been demonstrated for an 8 x 8 stripe, 64 "pixel" segment of our prototype. Relative anode and cathode pulse heights can be used to discriminate the third spatial dimension, the depth of interaction. An N x N orthogonal stripe detector module requires 2N signal processing channels and can achieve performance comparable to pixel detectors requiring N2 channels. 9. ACKNOWLEDGMENTS This work is supported by a 1993 Supporting Research and Technology grant under NASA's High Energy Astrophysics Gamma Ray Astronomy Research and Analysis program. 10. REFERENCES 1. M. L. Cherry, P. P. Altice, M. B. Bakarat, C. X. Chen, B. K. Dann, A. Drake, S.B. Ellison, C. J. Gagne, J. Gordon, T. G. Guzik, R. Lockwood, K. Johnston, J. Macri, M. L. McConnell, V. Nagarkar, J. M. Ryan and S. Vasile, "A New Balloon-Borne Detector for High Angular Resolution Hard X-Ray Astronomy", Proceedings, 24th International Cosmic Ray Conference, Rome, August 1995. 2. A. Parsons, C. M. Lisse, C. M. Stahle, N. Gehrels, B. J. Teegarden, S. Babu, N. Cao and P. Shu, "Room Temperature CdZnTe and HgI Detectors for Hard X-Ray Astrophysics", Proceedings, IEEE Nuclear Science Symposium, Norfolk, VA, 1994. 3. Skinner, G.K., "Imaging of Cosmic X-Ray Sources Using Coded Mask Techniques." Nuci. Instr. Methods Phys. Res., 221, 33, 1984. SPIE Vol. 2859 /35

4. F. P. Doty, J. F. Butler, J. Schetzina, K. Bowers, "Properties of CdZnTe crystals grown by a high pressure Bridgman method", Proc. 1991 U. S. Workshop on the Physics and Chemistry of HgCdTe and Other TI-VT Compounds, D. E. Seiler (Ed.), Journal ofvacuum Science and Technology B1O,1418, 1992. 5. J. F. Butler, F. P. Doty, B. Apotovsky, S. J. Friesenhahn, C. L. Lingren, "Progress in Cdl-xZnxTe radiation detectors", Semiconductorsfor room temperature radiation detector applications, R. B.James, 1. E. Schlessenger, P. Siffert and L. Franks (Eds.) Proc. Mat. Res. Soc., 302,497, 1993. 6. F. P. Doty, J. F. Butler and P. L. Hink, "X-Ray and Gamma Ray Imaging with Monolithic CdZnTe Detector Arrays", Proceedings, SPIE-OE/Aerospace Sensing, 1945, 145, Orlando, FL, 1993. 7. R. Polichar, R. Schirato, J. Reed, "Development of CdZnTe energy selective arrays for industrial and medical radiation imaging" Nuclear Instruments and Methods in Physics Research, A 353,349-355, 1994. 8. J.M. Ryan, B.A. Apotovsky, J.F. Butler, M.L. Cherry, B.K. Dann, F.P. Doty, T.G. Guzik, J.R. Macri and M.L. McConnell, "Large Area Sub-Millimeter Resolution CdZnTe Strip Detector for Astronomy", SPIE Conf Proc., San Diego, 292-301 (July, 1995). 9. J.R. Macri, B.A. Apotovsky, J.F. Butler, M.L. Cherry, B.K. Dann, A. Drake,F.P. Doty, T.G. Guzik, K. Larson, M. Mayer, M.L. McConnell and J.M. Ryan' Development of an Orthogonal-Stripe CdZnTe Gamma Radiation Imaging Spectrometer", IEEE Trans. Nucl. Sci., vol. 43,no. 4, to be published (Aug. 1996). 10. D.G. Marks, H.B. Barber, H.H. Barrett, E.L. Dereniak, J.D. Eskin, K.J. Matherson, J.M. Woolfenden, E.T. Young, F.L. Augustine, W.J. Hamilton, J.E. Venzon, B.A. Apotovsky, F.P.Doty, "A 48 x 48 CdZnTe array with multiplexer readout", IEEE Trans. Nucl. Sci., to be published (1996). 1 1, L.A. Hamel, J.R. Macri, C.M. Stable, J. Odom, F. Birsa, P. Shu, F.P.Doty, "Signal Generation in CZT Strip Detectors", in Conference Record, IEEE NSS, San Francisco, CA, October 1995. 12. Z. He, G. Knoll, D. Wehe, R. Rojeski, C. Mastrangelo, M. Hammig, C. Barrett, A. Uritani, 'id position sensitive single carrier semiconductor detectors", in Proceedings of9th International Workshop on Room Temperature Semiconductor X and Gamma Ray Detectors, Associated Electronics and Applications, Grenoble, France, September 1995, to be published in NIM. 13. J.C. Lund, R. Olsen, J.M. Van Scyoc and R.B. James, "The use of pulse processing techniques to improve performance of CdixZnxTe gamma-ray spectrometers", in Proceedings of 9th International Workshop on Room Temperature Semiconductor X and Gamma Ray Detectors, Associated Electronics and Applications, Grenoble, France, September 1995, to be published in NIM. 36 ISPIE Vol. 2859