DVS Application Note 46

Similar documents
DVS INTRINSIC. The easy-to-use solution to complex water sorption challenges.

Determination of Solubility Parameters using Inverse Gas Chromatography

Understanding Importance of Water Sorption Isotherm Shape, Hysteresis, and Models on Pharmaceutical Materials

DVS Intrinsic Compact and Economical Dynamic Vapor Sorption System

DVS Application Note 101


Thermal Analysis Excellence

Characterisation of Microporous Materials by Finite Concentration Inverse Gas Chromatography

Understanding Surface Energy

Pharmaceutical Characterisation. Dr. Lidia Tajber and Dr. Krzysztof Paluch School of Pharmacy and Pharmaceutical Sciences, Trinity College Dublin

DYNAMIC VAPOR SORPTION ANALYZER FULLY AUTOMATED COMPACT BENCH-TOP DVS ANALYZER, FOR FAST AND ACCURATE SORPTION MEASUREMENTS.

Automated multi-vapor gravimetric sorption analyzer for advanced research applications

Measuring TEWL or Moisture Flux Across Artificial Skin

Characterization of Surface Properties of Glass Fibers by Inverse Gas Chromatography

Characterization of Solid State Drugs by Calorimetry

Measurement techniques

RamanStation 400: a Versatile Platform for SERS Analysis

Characterization of Surface Properties of Glass Fibers by Inverse Gas Chromatography

Ultraviolet-Visible and Infrared Spectrophotometry

Polymorphism. Solid State Stability. Seminar overview

Comprehensive Handbook of Calorimetry and Thermal Analysis

Vibrational Spectroscopy of Molecules on Surfaces

What happens when light falls on a material? Transmission Reflection Absorption Luminescence. Elastic Scattering Inelastic Scattering

Quantification of Eplerenone Polymorphs by Diffuse Reflectance Infrared Fourier Transform Spectroscopy (DRIFTS)

Surface Measurement Systems

Vibrational Spectroscopies. C-874 University of Delaware

Ultraviolet-Visible and Infrared Spectrophotometry

The vibrational spectroscopy of polymers

Permeation Measurement Testing Techniques. Michelle Stevens MOCON, Inc.

Application of IR Raman Spectroscopy

Moisture Sorption Analysis of Pharmaceuticals

Advanced Spectroscopy Laboratory

Interaction of Microcrystalline Cellulose and Water in Granules Prepared by a High-Shear Mixer

ASAP: Accelerated Stability Assessment Program. Improved Protocol and Data Analysis for Accelerated Shelf-Life Estimation of Solid.

11/23/ (4) Harmonization Stage 6: <1241> Water Solid Interactions in Pharmaceutical Systems (USP34 NF29 2S) BRIEFING

Experiment AM3b: Raman scattering in transparent solids and liquids

Monitoring the Aggregation of Particles through Raman Spectroscopy

A56. Raman Spektroscopy. Jan Publisher: Institute of Physical Chemistry

Moisture Sorption Analysis of Pharmaceuticals

Dr Mingzhong Li School of Pharmacy, De Montfort University

ActiPix SDI300 Surface Dissolution Imaging System

Portable Raman Spectroscopy for the Study of Polymorphs and Monitoring Polymorphic Transitions

Secondary Ion Mass Spectrometry (SIMS)

Applications of Terahertz Radiation (T-ray) Yao-Chang Lee, National Synchrotron Research Radiation Center

The Influence of Processing-History on the Main Melting Temperature and Secondary Melting Temperature Using DSC. Stephen Sansoterra

Daniel Burnett,, Majid Naderi, Manaswini Acharya and Armando R. Garcia, Surface Measurement Systems Ltd.

Fourier transform infrared spectroscopy (FTIR) is a method used to obtain an infrared

I. Proteomics by Mass Spectrometry 1. What is an internal standard and what does it accomplish analytically?

Characterisation of vibrational modes of adsorbed species

Module 4 : Third order nonlinear optical processes. Lecture 28 : Inelastic Scattering Processes. Objectives

Formulation of Low Dose Medicines - Theory and Practice

DVS. Water Vapor Sorption Analyzer ADVENTURE

Fourier Transform IR Spectroscopy

Principles of Physical Biochemistry

From micro to nano - fundamentals and recent developments of Raman spectroscopy

TA INSTRUMENTS. Vapor Sorption Analysis

Conclusion and Future Work

Putting Near-Infrared Spectroscopy (NIR) in the spotlight. 13. May 2006

CHEM*3440. Photon Energy Units. Spectrum of Electromagnetic Radiation. Chemical Instrumentation. Spectroscopic Experimental Concept.

Snowy Range Instruments

UNIT 3 CHEMISTRY. Fundamental Principles in Chemistry

Technical brochure DuraLac H TABLETING DIRECT COMPRESSION ANHYDROUS LACTOSE

Investigation of H 2 :CH 4 Plasma Composition by Means of Spatially Resolved Optical Spectroscopy

Compact Hydrogen Peroxide Sensor for Sterilization Cycle Monitoring

Adsorption of Methylene Blue on Mesoporous SBA 15 in Ethanol water Solution with Different Proportions

Supplementary Information

FTIR Spectrometer. Basic Theory of Infrared Spectrometer. FTIR Spectrometer. FTIR Accessories

International Journal of Advanced Chemical Science and Applications (IJACSA)

Research Article Quantifying Solid-State Mixtures of Crystalline Indomethacin by Raman Spectroscopy Comparison with Thermal Analysis

Contents. xiii. Preface v

Determining Carbon Nanotube Properties from Raman. Scattering Measurements

Physicochemical Characterization of Binary Ionic Polymer Blends: Polyvinyl Acetate Phthalate and Eudragit E PO

Underwater Raman Sensor for Detecting High Explosives and Homemade Explosives (HMEs)

Supporting Information. for. Angew. Chem. Int. Ed. Z Wiley-VCH 2003

MS731M: Chemical Analysis of Materials

States of matter Part 2

New Developments in Wavelength-Dispersive XRF and XRD for the Analysis of Foodstuffs and Pharmaceutical Materials

Correlative Raman Imaging of Polymeric Materials

Infrared Spectroscopy: Identification of Unknown Substances

Journal of Pharmaceutical and Biomedical Analysis

COURSE DELIVERY PLAN - THEORY Page 1 of 6

Christin T. Choma TA Instruments, 109 Lukens Drive, New Castle, DE 19720, USA

Wire%4%Training%Modules%Compilation%! The!following!modules!are!in!this!compilation:!! TM001!! Introduction!to!Raman!Spectroscopy! TM002!!

Synthesis mechanism and gas-sensing application of. nanosheet-assembled tungsten oxide microspheres

Imaging Carbon materials with correlative Raman-SEM microscopy. Introduction. Raman, SEM and FIB within one chamber. Diamond.

CONFOCHECK. Innovation with Integrity. Infrared Protein Analysis FT-IR

FACULTY OF PHARMACY. M. Pharmacy I Semester (Suppl.) Examination, November 2015 (Common To All) Subject: Pharmaceutical Analytical Techniques

Spectroscopy in Transmission

Raman and stimulated Raman spectroscopy of chlorinated hydrocarbons

Determination of Carbon Fibre-Polymer Interactions by Inverse Gas Chromatography

PAPER No. 12: ORGANIC SPECTROSCOPY MODULE No. 7: Instrumentation for IR spectroscopy

Preformulation & Solid State Chemistry Services

Electronic Properties of Materials An Introduction for Engineers

Interaction between Single-walled Carbon Nanotubes and Water Molecules

Session #1: Theoretical background and computer simulations of molecular vibrations.

Hydrogen content of CeCl 3 -doped sodium alanate powder samples measured in-situ by ATR-FTIR-spectroscopy and gravimetry during desorption

Analyzer for Determination of the Composition of Deposits in Nuclear Power Plants

CHAPTER A2 LASER DESORPTION IONIZATION AND MALDI

Spectroscopy tools for PAT applications in the Pharmaceutical Industry

Transcription:

Combining Raman Spectroscopy with Gravimetric Vapour Sorption Analysis for Pharmaceutical Materials Dan Burnett, Duncan Pearse and Nishil Malde, Surface Measurement Systems Ltd. DVS Application Note 46 Raman spectroscopy is a widely used physical characterization technique used in the pharmaceutical industry. The combination of Raman spectroscopy and Dynamic Vapour Sorption (DVS) allows for a more complete understanding of vapour-solid interactions for pharmaceutical materials as it relates to structural properties. This paper overviews the DVS-Raman capabilities and gives several examples Introduction The interactions of water vapour with solid materials have impact over a wide range of industries and materials. In particular, in the pharmaceutical industry the physical and chemical performance (i.e. flow, compaction, dissolution, stability, storage, and formulation) of drugs, excipients, and packaging materials are dependent on the presence and interaction of/with water [1]. Dynamic gravimetric vapour sorption instruments have now become the standard method for investigating the vapour sorption properties for pharmaceutical materials. The combination of additional techniques with DVS can further enhance the understanding of how vapour interacts with solid materials. For instance, in-situ optical microscopy can confirm structural changes indicated by the gravimetric data [2,3]. Additionally, vibrational spectroscopic techniques, such as Near-IR [4,5] and Raman spectroscopy [6] have also been combined with gravimetric sorption methods. This paper describes the first turn-key solution for the combination of Raman spectroscopy with gravimetric vapour sorption analysis. Theory Raman spectroscopy is a technique used to study vibrational, rotational, and other low-frequency modes in a system [7]. Monochromatic radiation can interact with a material by reflecting, absorbing, or scattering the light. Raman spectroscopy is the measurement and detection of the wavelength and intensity of inelastically scattered light from molecules, i.e. the Raman effect. When electromagnetic radiation passes through matter, most of the radiation continues in its original direction but a small fraction is scattered in other directions, such as: Rayleigh scattering (light that is scattered at the same wavelength as the incoming light) or Raman scattering (light that is scattered at a different wavelength due to vibrations in molecules or optical phonons in solids). Raman spectroscopy can be used to study the crystal lattice and intermolecular vibrations and has proved to be a useful tool to investigate structural properties. Raman spectroscopy is ideal for use in the DVS for several reasons. First, sampling techniques are relatively straightforward since the only requirement is that the laser irridates the material and the scattered radiation can be focused on a detector [8]. Also, sample prep is minimal and Raman spectroscopy requires small samples P-SCI-265 v1.0 12MAR2012

(typically a few milligrams). Glass and stainless steel are common holders for Raman samples, making DVS pans ideal for Raman spectroscopy. In particular, glass is a very weak Raman scatterer. In particular to DVS experiments, Raman is an ideal spectroscopic choice of technique due to the low Raman activity of water vibrations [9]. Method A picture of the DVS-Advantage system with integrated Raman probe is shown in Figure 1a. The close up picture in Figure 1b illustrates how the Raman probe interfaces with the DVS chamber. The laser used has a wavelength of 785nm. The details of the Raman system (detector and spectrometer) are listed in Table 1. The temperature range of the simultaneous DVS- Raman system is 5 C to 50 C. The Raman probe is 130mm in length. The above specifications are for the DVS-Raman measurements done in this study. However, it is possible to interface virtually any Raman system, provided the Raman probe is of compatible size with the DVS-Advantage system. Figure 1(a.) Figure 1(b.) Figure 1. DVS-Advantage system with Raman probe (a.) and close-up view of Raman probe port (b.).

Table 1. Raman detector and spectrometer specifications Detector Property Specification Spectrom eter Property Type Hamamatsu S7031-1003 Waveleng th Range Range 200-1100 nm Optical Resolutio n Pixels 1024 x 58 (1044 x 64 Signal-tonoise total pixels) ratio Pixel size 24.576 µm square size A/D resolution Pixel well depth Sensitivity Quantum efficiency Results 3000,000 electrons/well; ~1.5 million electrons/column 22 electrons/count for all wavelengths; 250 nm: 26 photons/count 90% peak; 65% at 250 nm Polymorphic Forms Dark noise Dynamic Range Specification Grating dependent ~0.14-7.7 nm FWHM 1000:1 (at full signal) 16 bit 3 RMS counts 7.5x109 (system); 25000:1 for a single acquisition 8 ms to 15 minutes Integratio n time Stray light <0.08% at 600 nm; 0.4% at 435 nm Corrected linearity >99.8% Raman spectroscopy can probe the lattice vibrations that are associated with the solid, crystalline state. The lattice vibrations for different polymorphs will result in unique, characteristic spectra for each polymorph [8,10]. Therefore, Raman spectroscopy has long been used in the pharmaceutical industry to identify different polymorphic forms. In addition, Raman spectroscopy has been used to quantitatively determine different polymorphic mixtures of cortisone acetate [11]. Hydrates Raman spectroscopy can be especially sensitive to spectra shifts due to changes in hydrogen bonding. Therefore, Raman spectroscopy is an ideal complement with DVS data to confirm hydration/dehydration phenomena. To illustrate, the Raman results for anhydrate and monohydrate forms of baclofen produced unique spectra for each species [12]. Additionally, Raman spectra confirmed the transformation of sulfaguanidine anhydrate to the monohydrate species as the humidity was increased from 60% RH to 75% RH (at 25 C) [6]. Differences in Raman spectra between hydrate and anhydrate forms has even been detectible in the presence of excipients [13]. Figure 2 displays the DVS moisture sorption/desorption isotherms for anhydrous theophylline (Figure 2a) and corresponding Raman spectra (Figure 2b) taken at the end of each humidity step. Theophylline remains anhydrous until the 70% RH sorption step. The sharp mass increase is indicative of hydrate formation [14]. On the desorption side, the sample remains hydrated until the humidity decreases below 30% RH. As Figure 2b indicates, the spectra for the anhydrous material (0% RH adsorption, 50% RH adsorption, and 0% RH desorption steps) are clearly different than the spectra for the hydrated species (90% RH adsorption and 80% desorption steps). Similar differences in Raman spectra were observed previously for anhyhdrous and hydrated materials [6,12]. Figure 2(a.)

7000 6000 Raman scan - Theophilline Theophylline Monohydrate clearly defined than the amorphous spectra. This is typical for Raman spectra on the amorphous phase. 5000 Intensity (counts) 4000 3000 2000 Anhydrous Theophylline 0%RH ads 50%RH ads 90%RH ads 80%RH des 0%RH des 1000 0 0 500 1000 1500 2000 2500 3000 3500 4000 4500 Wavelength (nm) Figure 2(b.) Figure 2. DVS water sorption/desorption isotherm (a.) and in-situ Raman spectra (b.) for theophylline at 25 C. Amorphous Materials Raman spectroscopy has also been used to differentiate between the amorphous and crystalline phases of the same material. This usually manifests in a broadening of the spectra by the amorphous material compared to the crystalline phase [10]. In fact, Raman spectroscopy has been used to quantify varying amorphous contents [15]. However, careful consideration must be used towards obtaining representative Raman spectra for mixtures. Figure 3 shows the water sorption/desorption profile (a,) and corresponding Raman spectra (b.) for amorphous lactose at 25 C. The DVS sorption profile clearly shows the humidityinduced crystallization for amorphous lactose at the 60% RH step. This is a well-known and wellcharacterized phenomenon for amorphous lactose [16]. In essence, the amorphous material has a greater water vapor sorption capacity than the crystalline material, due to increased void space, free energy, and/or surface area. When the material undergoes an amorphous to crystalline transition, the water sorption capacity decreases drastically, resulting in a net mass loss as excess water is desorbed during crystallization. The corresponding Raman results in Figure 3b, shows a dramatic change in the spectra before crystallization versus after crystallization. The crystalline spectra are much lower in intensity and the features are more Figure 3(a.) Figure 3(b.) Figure 3. DVS water sorption/desorption results (a.) and in-situ Raman spectra (b.) for amorphous lactose at 25 C. Other Raman spectroscopy can also be sensitive to changes in hydrogen bonding and other subtle reorientation of the solid material. For instance, Raman spectroscopy has been previously used to determine the changes in strength of hydrogen

bonding between water and different pharmaceutical polymers [17]. In the same study, changes in Raman spectra due to water plasticizing the polymers have been observed. Figure 4 displays the water sorption/desorption (a.) and Raman spectra (b.) for microcrystalline cellulose (MCC) at 25 C. MCC is not expected to form a hydrated species or undergo and polymorphic transformation when exposed to increasing humidity. However, there are clear differences in the Raman spectra as the humidity is increased. MCC does experience a significant amount of bulk water absorption as humidity is increased. Therefore, the changes observed in Figure 4b could be due to increased hydrogen bonding, decrease in void spaces, or other structural rearrangements. Raman spectroscopy has also been previously used to identify sample deliquescence as a sample of ranitidine HCl is exposed to a relative humidity above the critical deliquescence point [6]. The combination of Raman spectroscopy and gravimetric vapor sorption analysis has applications ranging beyond the pharmaceutical industry. For instance, water sorption and Raman studies have been performed on different proton conducting membranes for fuel cell applications [18,19]. Combined water sorption and Raman studies on the hydration of Nafion membranes confirm that the polymers retain the helical zigzag conformation of the polytetrafluoroethylene [18]. Additionally, Raman spectra were able to differentiate water sorption properties between porous and non-porous proton conducting polymers [19]. Water sorption and Raman spectroscopy studies have also been performed on different polymers, including Nylon 6 [20], Kevlar-49 [21], and poly(vinyl alcohol) [22]. Further, the mechanisms of moisture sorption on different barrier polymers for food packaging applications has been previously investigated [23]. Researchers found that water associates with the packaging materials greatly affects the oxygen barrier properties of the different polymers. Other materials for which Raman spectroscopy has been used to study vapor sorption include silica gels [24], silver [25], carbon nanotubes [26], and starch [6]. In all, the combination of Raman spectroscopy with gravimetric vapor sorption instrumentation has far reaching applications over a range of industries. Figure 4(a.) Figure 4(b.) Figure 4. DVS water sorption/desorption results (a.) and in-situ Raman spectra (b.) for MCC at 25 C.

Conclusion The combination of gravimetric vapour sorption and in-situ Raman spectroscopy can be a powerful tool in determining how water interacts with various materials. Raman spectroscopy is an ideal complementary technique to DVS due to its relatively low sample preparation and small sample size requirements and weak interactions with water molecules. These combined techniques can investigate a range of pharmaceutical applications: hydration/dehydration, polymorph identification/transformation, amorphous to crystalline transformation, hydrogen-bonding, and deliquescence. In addition, when used in tandem, these techniques have various applications for different materials and industries. References 1 Khankari, R.K. and Zografi, G., Sorption of water by solids. In: Brittain H.G., editor. Physical Characterization of Pharmaceutical Solids. New York: Marcel Dekker, Inc., pp 387-418. 2 SMS Application Note 10 3 D.J. Burnett, N. Malde, and D. Williams, Pharm. Technology Asia Pacific, December (2008) 19-22. 4 R.A. Lane and G. Buckton, Int. J. Pharm., 207 (2000) 49-56. 5 K.L. Vora, G. Buckton, and D. Clapham, Eur. J. Pharm. Sci., 22 (2004) 97-105. 6 A.D. Gift and L.S. Taylor, J. Pharm. And Biomedical Analysis, 43 (2007) 14-23. 7 D.J. Gardiner, Practical Raman Spectroscopy, Springer-Verlag, New York 1989. 8 D.E. Bugay, Advanced Drug Delivery Reviews, 48 (2001) 43-65. 9 A.M. Amado, M.M. Nolasco, and P. J.A. Ribeiro-Claro, J. Pharm. Sci., 96 (2007) 1366-1379. 10 L. Yu, S.M. Reutzel, and G.A. Stephenson, PSTT, 1 (1998) 118-127. 11 C.M. Deeley, R.A. Spragg, and T.L. Threlfall, Spectromchim. Acta, 47A (1991) 1217-1223. 12 S. Mirza, I. Miroshnyk, J. Rantanen, J. Aaltonen, P. Harjula, E. Kiljunen, J. Heinamaki, and J. Yliruusi, J. Pharm. Sci., 96 (2007) 2399-2408. 13 S. Airaksinen, P. Luukkonen, A. Jørgensen, M. Karjalainen, J. Rantanen, and J. Yliruusi, J. Pharm. Sci., 92 (2003) 516-528. 14 SMS Application Note 36. 15 L.S. Taylor and G. Zografi, Pharm. Res., 15 (1998) 755-761. 16 D.J. Burnett, F. Thielmann, and J. Booth, Int. J. Pharm., 287 (2004) 123-133. 17 L.S. Taylor, F.W. Langkilde and G. Zografi, J. Pharm. Sci., 90 (2001) 888-901. 18 A. Gruger, A. Regis, T. Schmatko, and P. Colomban, Vibrational Spectroscopy, 26 (2001) 215-225. 19 D.I. Ostrovskii, L.M. Torell, M. Paronen, S. Hietala, and F. Sundholm, Solid State Ionics, 97 (1997) 315-321. 20 B.H. Stuart, Polymer Bulletin, 33 (1994) 681-686. 21 B.H. Stuart, Polymer Bulletin, 35 (1995) 727-733. 22 P.S. Thomas and B.H. Stuart, Spectrochimica Acta Part A, 53 (1997) 2275-2278. 23 J.M. Lagaron, E. Gimenez, R. Catala, and R. Gavara, Macromolecular Chemistry and Physics, 204 (2003) 704-713. 24 D. Krol, Journal of Non-Crystalline Solids, 68 (1984) 163-166. 25 I. Pockrand, Surface Science, 122 (1982) L569-L573. 26 S.C. Sharma, D. Singh, and Y. Li, Journal of Raman Spectrometry, 36 (2005) 755-761. Head Office: Surface Measurement Systems, Ltd 5 Wharfside, Rosemont Road LondonHA0 4PE, UK United States Office: Surface Measurement Systems, Ltd, NA 2125 28 th Street SW, Suite I Allentown PA, 18103, USA Tel: +44 (0)20 8795 9400 Tel: +1 610 798 8299 Fax: +44 (0)20 8795 9401 Fax: +1 610 798 0334 Email: science@surfacemeasurementsystems.com