The temperature coefficient of the resonance integral for uranium metal and oxide

Similar documents
Reactivity Effect of Fission and Absorption

Energy Dependence of Neutron Flux

PARAMETERISATION OF FISSION NEUTRON SPECTRA (TRIGA REACTOR) FOR NEUTRON ACTIVATION WITHOUT THE USED OF STANDARD

M.Cagnazzo Atominstitut, Vienna University of Technology Stadionallee 2, 1020 Wien, Austria

The resonance integral of thorium metal rods. E. Hellstrand and J. Wettman

Nuclear Fission. 1/v Fast neutrons. U thermal cross sections σ fission 584 b. σ scattering 9 b. σ radiative capture 97 b.

SUB-CHAPTER D.1. SUMMARY DESCRIPTION

17 Neutron Life Cycle

MONTE CALRLO MODELLING OF VOID COEFFICIENT OF REACTIVITY EXPERIMENT

Measurement of the Westcott Conventionality Thermal Neutron Flux and Suchlike at Irradiation Facilities of the KUR

ENT OF THE RATIO OF FISSIONS IN U TO FISSIONS OF. IN U USING 1.60 MEV GAMMA RAYS THE FISSION PRODUCT La 14 0 MEASUREM

CALCULATION OF TEMPERATURE REACTIVITY COEFFICIENTS IN KRITZ-2 CRITICAL EXPERIMENTS USING WIMS ABSTRACT

The Dancoff correction. in various geometries. /. Carlvik, B. Pershagen

AKTIEBOLAGET ATOMENERGI

Reactivity Coefficients

Validation of the MCNP computational model for neutron flux distribution with the neutron activation analysis measurement

The possibility to use energy plus transmutation set-up for neutron production and transport benchmark studies

The Possibility to Use Energy plus Transmutation Setup for Neutron Production and Transport Benchmark Studies

VERIFICATION OF MONTE CARLO CALCULATIONS OF THE NEUTRON FLUX IN THE CAROUSEL CHANNELS OF THE TRIGA MARK II REACTOR, LJUBLJANA

1 Introduction MCNPX SIMULATIONS OF THE ENERGY PLUS TRANSMUTATION SYSTEM: NUCLEAR TRACK DETECTORS

Control of the fission chain reaction

Chem 481 Lecture Material 4/22/09

X. Assembling the Pieces

Effect of Co-60 Single Escape Peak on Detection of Cs-137 in Analysis of Radionuclide from Research Reactor. Abstract

Lesson 14: Reactivity Variations and Control

CRITICAL AND SUBCRITICAL EXPERIMENTS USING THE TRAINING NUCLEAR REACTOR OF THE BUDAPEST UNIVERSITY OF TECHNOLOGY AND ECONOMICS

(a) (i) State the proton number and the nucleon number of X.

Low dimensional neutron moderators for enhanced source brightness

Fuel Element Burnup Determination in HEU - LEU Mixed TRIGA Research Reactor Core

Effect of Resonance Scattering of Sodium on Resonance Absorption of U-238

Reactor & Spallation Neutron Sources

Advanced Heavy Water Reactor. Amit Thakur Reactor Physics Design Division Bhabha Atomic Research Centre, INDIA

New Neutron-Induced Cross-Section Measurements for Weak s-process Studies

USA HTR NEUTRONIC CHARACTERIZATION OF THE SAFARI-1 MATERIAL TESTING REACTOR

Nuclear Reactions A Z. Radioactivity, Spontaneous Decay: Nuclear Reaction, Induced Process: x + X Y + y + Q Q > 0. Exothermic Endothermic

Determination of the Neutron Flux in the Reactor Zones with the Strong Neutron Absorption and Leakage

Materials Science. Fission Chamber Calibration Tests at NRU

Introduction. 1. Neutron reflection cross section

Lamarsh, "Introduction to Nuclear Reactor Theory", Addison Wesley (1972), Ch. 12 & 13

Benchmark Tests of Gamma-Ray Production Data in JENDL-3 for Some Important Nuclides

LOS ALAMOS SCIENTIFIC LABORATORY of the University of California

Considerations for Measurements in Support of Thermal Scattering Data Evaluations. Ayman I. Hawari

He-3 Neutron Detectors

Neutronic Calculations of Ghana Research Reactor-1 LEU Core

JOYO MK-III Performance Test at Low Power and Its Analysis

EFFECT OF DISTRIBUTION OF VOLUMETRIC HEAT GENERATION ON MODERATOR TEMPERATURE DISTRIBUTION

Investigation of anomalous heat production in Ni-H systems

POWER DENSITY DISTRIBUTION BY GAMMA SCANNING OF FUEL RODS MEASUREMENT TECHNIQUE IN RA-8 CRITICAL FACILITY

ANALYSIS OF TRANSIENT HEAT CONDUCTION IN DIFFERENT GEOMETRIES BY POLYNOMIAL APPROXIMATION METHOD

Fuel BurnupCalculations and Uncertainties

Neutronics Experiments for ITER at JAERI/FNS

Invariability of neutron flux in internal and external irradiation sites in MNSRs for both HEU and LEU cores

GCSE 0247/02 SCIENCE HIGHER TIER PHYSICS 3

Determination of the boron content in polyethylene samples using the reactor Orphée

PhD Qualifying Exam Nuclear Engineering Program. Part 1 Core Courses

MONTE CARLO SIMULATION OF THE GREEK RESEARCH REACTOR NEUTRON IRRADIATION POSITIONS USING MCNP

H2 Physics Set A Paper 3 H2 PHYSICS. Exam papers with worked solutions. (Selected from Top JC) SET A PAPER 3.

Reactors and Fuels. Allen G. Croff Oak Ridge National Laboratory (ret.) NNSA/DOE Nevada Support Facility 232 Energy Way Las Vegas, NV

Analysis of the TRIGA Reactor Benchmarks with TRIPOLI 4.4

PHYSICS 359E: EXPERIMENT 2.2 THE MOSSBAUER EFFECT: RESONANT ABSORPTION OF (-RAYS

RECH-1 RESEARCH REACTOR: PRESENT AND FUTURE APPLICATIONS

AE 3051, Lab #16. Investigation of the Ideal Gas State Equation. By: George P. Burdell. Group E3

Detekce a spektrometrie neutronů. neutron detection and spectroscopy

2. Which of the following statements help(s) to explain why gas can fill the vessel containing it completely while liquid cannot?

APPROVED FOR PUBLIC RELEASE i. LOS ALAMOS SCIENTIFIC LABORATORY of the UNIVERSITY OF CALIFORNIA. This document consists of 22 pages

Profile SFR-64 BFS-2. RUSSIA

Application of prompt gamma activation analysis with neutron beams for the detection and analysis of nuclear materials in containers

On the Calculation of the Fast Fission Factor

Cambridge International Examinations Cambridge International Advanced Subsidiary and Advanced Level

Sensitivity and Uncertainty Analysis Methodologies for Fast Reactor Physics and Design at JAEA

NATURAL CONVECTION HEAT TRANSFER CHARACTERISTICS OF KUR FUEL ASSEMBLY DURING LOSS OF COOLANT ACCIDENT

The Lead-Based VENUS-F Facility: Status of the FREYA Project

Neutron reproduction. factor ε. k eff = Neutron Life Cycle. x η

Reactivity Power and Temperature Coefficients Determination of the TRR

Institute of Atomic Energy POLATOM OTWOCK-SWIERK POLAND. Irradiations of HEU targets in MARIA RR for Mo-99 production. G.

Measurements of Neutron Capture Cross Sections for 237, 238 Np

FISSILE MATERIALS DETECTION VIA NEUTRON DIFFERENTIAL DIE-AWAY TECHNIQUE

DESIGN OF B 4 C BURNABLE PARTICLES MIXED IN LEU FUEL FOR HTRS

Activation Analysis. Characteristic decay mechanisms, α, β, γ Activity A reveals the abundance N:

DETERMINATION OF NEUTRON-INDUCED ACTIVATION CROSS SECTIONS USING NIRR-1

Nuclear Physics. (PHY-231) Dr C. M. Cormack. Nuclear Physics This Lecture

Neutron capture cross sections on light nuclei

PIA and REWIND: Two New Methodologies for Cross Section Adjustment. G. Palmiotti and M. Salvatores

NPL REPORT DQL RN008. Thermal fluence and dose equivalent standards at NPL. David J. Thomas and Peter Kolkowski NOT RESTRICTED.

ISSUES TO ADDRESS...

SENSITIVITY ANALYSIS OF ALLEGRO MOX CORE. Bratislava, Iľkovičova 3, Bratislava, Slovakia

REACTOR PHYSICS ASPECTS OF PLUTONIUM RECYCLING IN PWRs

Alpha-Energies of different sources with Multi Channel Analyzer


Neutron Based Techniques for the Detection of Illicit Materials and Explosives

Universal curve of the thermal neutron self-shielding factor in foils, wires, spheres and cylinders

The New Sorgentina Fusion Source Project

Testing of Nuclear Data Libraries for Fission Products

Chapter 3: Neutron Activation and Isotope Analysis

Review of nuclear data of major actinides and 56 Fe in JENDL-4.0

Higher -o-o-o- Past Paper questions o-o-o- 3.6 Radiation

Theoretical Task 3 (T-3) : Solutions 1 of 9

X. Neutron and Power Distribution

Neutronic analysis of SFR lattices: Serpent vs. HELIOS-2

A. Aleksanyan, S. Amirkhanyan, H. Gulkanyan*, T. Kotanjyan, L. Poghosyan, V. Pogosov

Transcription:

AE-22 m The temperature coefficient of the resonance integral for uranium metal and oxide P. Blomberg, E. Hellstrand and S. Homer AKTIEBOLAGET ATOMENERGI STOCKHOLM SWEDEN I960

Errata and addendum to AE-22 Title: The temperature coefficient of the resonance integral for uranium metal and oxide. Authors: Blomberg P, Hellstrand E & Hörner S Date: April I960 Errata This is a preliminary report, which, by mistake, has been reproduced and distributed as an AE -report. Because of a faulty component in the temperature reading device some of the results given in the report will be subject to large corrections. The report will therefore serve only as an indication of the type of measurements performed. The results should not be used in calculations and it is requested that they should not be quoted in other reports. A new report will appear early in the fall I960. The authors Addendum: Completion of manuscript: 22 June 1959

AE-22 The temperature coefficient of the resonance integral for uranium metal and oxide P. Blomberg, R Hellstrand and S. Hörner Summary: The temperature coefficient of the resonance integral in uranium metal and oxide has been measured over a wide temperature range for rods with three different diameters. The results for metal agree with most earlier results from activation measurements but differ as much as a factor of two from results obtained with reactivity methods. For oxide only one measurement has been reported recently. Our value is considerably lower than the result of that measurement. The experiments will continue in order to find the reason for the large discrepancy mentioned above. Printed April 1960

LIST OF CONTENTS Page 1. Introduction i 2. Experimental procedure 2 3. Results 4 References 13 Legend to the figures 14

The temperature coefficient of the resonance integral for uranium metal and oxide. P. Blomberg, E. Hellstrand, S. Homer 1. Introduction. in U O o Q It is well known that the Doppler broadening of the resonances increases the effective resonance absorption in uranium lumps. This effect acts as a prompt negative temperature coefficient in a reactor fuelled with natural or slightly enriched uranium and its contribution to the stability of a reactor is at least for some reactor types of great importance. Several measurements of the temperature coefficient of the resonance integral have been performed in the past. The well known 1) measurements on resonance absorption by Creutz et al. included studies of the temperature dependence in uranium oxide (UO? ). Contrary to most of the later measurements samples with different surface to mass ratios were used. The result indicated an increase in the volume absorption and a decrease in the surface absorption with temperature. The accuracy of the measurement was for several reasons not very high. More recent measurements have been performed by Egiazarov, Dikarev and Madeev (2), Adyasevich, Frank, Kozinets, Shapiro, Shtranik and Tolstov (3), Panasyuk (quoted in (3) ), Rodeback (4), Davis (5), Pearce and Walker (6), Pearce (7), Small (8) and by Engesser (9). The measurements described in Ref. (2)-(8) were made on uranium metal and that in Ref. (9) on a cluster of 19 rods of uranium oxide. Egiazarov et al. (2), Rodeback (4) and Pearce (7) have used the activation technique, the others various kinds of reactivity methods. In (2) and (8) the measurements were made on samples of different surface to mass ratios but in the other cases only one dimension was used. In Pearce 's experiment not only the mean temperature coefficient was measured but also the radial dependence of the Doppler effect. The results from the measurements have been expressed in different forms. In some cases the whole temperature effect has been attributed to the volume absorption part of the resonance integral, in

others the temperature coefficient has been given as the relative change of the total resonance absorption per unit temperature. In the latter case the l/v-part of the absorption may or may not be included. The temperature coefficient has in these cases been considered independent of temperature and it is thus a mean value over the temperature range used. The results given in (2), on the other hand, have been put into the form of a semiempirical formula foj* In p, giving this quantity as a function of UT (T in K). The temperature coefficient derived -l/2 from this formula varies with temperature approximately as T. Besides the experimentally obtained values of the temperature coefficient, recent developments in the theory of resonance absorptioh in lumps allow the effective resonance integral and its temperature dependence to be calculated theoretically. The most important work is that of Dresner (10), (11) and of Adler, Hinman and Nordheim (jl_2)- In the latter publication the change in resonance absorption over the temperature range 300 K - 600 K is given for uranium metal rods of different sizes. In addition, formulas and tables are given, allowing for instance the temperature effects in uranium oxide to be calculated. Such calculations have been made at AB Atomenergi by J. Rosén and the result will be discussed later on. A numerical calculation of the temperature effect, based mostly on Dresner's work, has also been made by Brimberg and Dahlström (13). This calculation is, however, more approximate than the work by Adler et al. The present investigation was initiated because of the lack of data on uranium oxide, and in addition it was considered worth-while to repeat a study of the surface-to-mass dependence of the temperature coefficient. Measurements have thus been made on uranium metal as well as oxide and on rods of three different diameters. 2. Experimental procedure. 2.1 Method. The experimental method is similar to that used for the measurement of the effective resonance integral (14). Rods of uranium metal or uranium oxide were placed in a cadmium covered oven and irradiated in the Swedish heavy water reactor Rl. The epithermal flux

239 was monitored with the aid of gold foils. The induced Np activity in suitable samples was measured for different temperatures of the oven, and, normalized to unit gold foil activity, these activities represent a 238 comparable measure of the epithermal capture of neutrons in U 2.2 Samples. The samples of uranium metal and oxide (UO-,) were cylindrical. They were mounted between end pieces of the same material forming a rod of uniform diameter about 90 mm long. The diameters used were 8, 12.5 and 28 mm both in the metal and oxide cases. The metal samples were about 4 mm thick, the 8 and 12.5 mm oxide samples (density 10. 3 g/cm ) were 10 mm thick and the 28 mm oxide samples ( density 9.7 g/cm ) 7. 4 mm thick. The oxide samples were in the form of sintered pellets, carefully ground with a diameter tolerance of - 0.01 mm and a length tolerance of - 0. 1 mm. 2.3 In-pile apparatus. Originally a set of measurements was made with the oven placed in the reflector of the reactor. However, since the epithermal flux gradient there is large and since the energy dependence might deviate from l/e, it was considered worth-while to repeat some of the measurements with the oven placed in the central channel of the reactor. To minimize the necessary amount of cadmium the oven was made somewhat shorter than in the reflector case, but except for this the apparatus were identical in the two sets of measurement. The position of the oven in the two cases is shown in Fig. 1. The apparatus (Fig. 2) consisted of three parts, the cadmium covered holder which was fixed in the channel used, the oven unit, and the gold monitor unit. The latter two were removable for reloading. The oven consisted of a ceramic tube wound with resistance wire. A thin layer of aluminium oxide served as an outer insulation medium. The metal and oxide rods were mounted in thin-walled iron tubes and placed against a stop in the ceramic tube, thus securing a well defined position relative to the ceramic tube. The tube was fastened to a steel rim, the position of which was checked with a long quartz rod, using a dial indicator placed on the outer end of the gold monitor holder.

The holder was water cooled and its length therefore independent of the temperature of the oven. Thus only the change in position of the sample caused by the difference in thermal expansion between the ceramic tube and the rods had to be corrected for. This fairly elaborate method of checking the position of the samples had to be used because of the large gradient in the epithermal neutron flux. The temperature was measured with a thermocouple in one of the end pieces. The difference between the thermocouple reading and the temperature of the sample was determined by a separate calibration. 2.4 Exposure procedure and counting methods. The samples were heated in the reactor to the required temperature and then irradiated for 40 minutes. The power of the reactor was 40 kw for the reflector runs and 4 kw for the central channel runs. The irradiated samples were dissolved in nitric acid giving solutions of known concentration and uniform activity. Samples for measurements were prepared by pipetting a well determined amount of the solution into a cylindrical teflon container. The Y-activity of the samples was measured in a narrow energy band around the 106 kev-peak 239 in Np After corrections for the fission product activity, the natural disintegration of uranium, and background, these activities are propor- 238 tional to the U neutron capture- GM -counters. 3» Results. The 0-activity of the gold monitors was measured with two With the aid of the tables given in (12) the resonance integrals for metal and oxide have been calculated for different temperatures and different surface to mass ratios. It is found that a plot of the theoretical values as a function of \/T (T in K) is very well fitted with a straight line. We therefore assume that the y T-dependence of the resonance integral is theoretically more correct than the fit linear in t (t in C). Unfortunately, the uncertainty in the experimental points and the lack of data in the low temperature range (100-300 C) have * The authors are very much indebted to J. Rosen, who has made the result of these calculations available before publication.

made it impossible to verify this experimentally. We have plotted our points both as a function of UT and of t, the latter for allowing a comparison with earlier values of the temperature coefficient. As the thermal expansion of the rods increases the resonance integral,our specific activities were first corrected for this effect. Mean values of the thermal expansion coefficients in the different crystal directions were used, assuming no texture in the rods. This assumption is questionable, but as the effect of the thermal expansion is small it may be permissible. If the corrected activities are called A(T) or A(t) (T in K and t in C) we have fitted our results to the following two expressions: A(T). A(T O ) A(T o ) "» a ( fi - fe) ti] 1/ RI A(t) = A(t o ) + A(t o ) -2 ^(t-t o ) [2] o l/v A(T ) or A(t ) is the activity at room temperature. A(T) or A(t) is the activity at the temperature T K or t C. Cw is the epicadmium l/v cross section. RI is the effective resonance integral at room temperature. a and /3 are the temperature coefficients. As the l/v-part of the epithermal absorption is independent of temperature, the a- and ^-values in Eqs 1 and 2 have been defined to mean the relative change in the resonance integral only, per unit (^T - \'T O ) and (t - t Q ) respectively. The RI values for the different surface-to-mass ratios were o determined from the expressions in (14). cr, was put equal to 1.1b, which corresponds to a cadmium cut off of about 0.6 ev for the 1 mm thick cadmium cover used in the experiments.

Table I. Diam. mm, n 2 /Ot.l/2 a x 10 / K ' 0 x 10 4 / C 8 0.63 t 0.03 1.37 t 0.08 Metal 12.5 0.65-0.06 1.41 t 0.12 28 0.40 t 0.04 0.83 t 0.08 8 0,69-0.03 1.39-0.07 Oxide 12.5 0,66-0.03 1.34 t 0.07 28 0.45-0.03 0.86 t 0.07 The experimental points were fitted to the expressions [1] and [2] by the method of least squares. The a- and j3-values obtained are given in Table I. The dependence of the coefficient on the surface to mass ratios is clearly demonstrated. The fact that the coefficient for the 12. 5 mm diam. metal rod is slightly larger than that for the 8 mm diam. rod is believed to be accidental and dependent on the large uncertainties in the former value. In Figs. 3-8 the ratios RI SET RI - A(T Q ) "l/v o' RT O 1/ for the different rods are given as RI o A < T o> l/v functions of y T - \ T. Fig. 9 gives an example the fit linear in t. From Fig. s 3, 5 and 6 it may be seen that there is good agreement between the results from the central channel and reflector runs. Figures 3-8 also contain the results of the theoretical calculations. In the metal case the agreement is reasonable except for the 28 mm rods but for the oxide the experimental values are considerably lower than the theoretical ones. In Figs 10 and 11 the experimental and theoretical a-values for metal and oxide have been plotted as functions of S/M. NO analyti-

cal expression has been fitted to the experimental points, as only three points are available. Besides these groups of»-values the results obtained by Egiazarov et al. (2) for uranium metal are also shown in Fig. 10. To obtain values of a from (2)we have rewritten the given expression In - 5 «87 x 0-7? 5 (1 + 17. 5 10" 3 V T) P 3 ' 2 + 3. 02 P 2 P 2 ffp 2 a - _. is the diam, of the rods 2 a - 2 4 is the moderator part of the lattice cell surface in the following approximately equivalent form RI = RI o [i + 0.282^_ (\ ^-\ T)] [3] As may be seen, their a-values are considerably higher than the others, but the general form is very much the same. An indication of the S/M-dependence of a therefore may be obtained from the factor in the (\/T - \\ T Q ) term in Eq. 3. Sources of error» The main quantities measured are the temperature, the Npactivity and the monitor activity. The estimated standard deviations in the calibrated temperature values are less than 2% in the reflector runs and 5 to 6 % in the central channel runs. The reason for the large uncertainty in the latter runs was an unexpectedly large temperature gradient in the short oven used in these runs. Fortunately an uncertainty in the temperature is considerably less important than the same relative error in the measured activity. The adopted specific Np-activity for each run was a mean of 5-10 different measurements under identical conditions. The standard deviation in the mean values was less than 0.5 %.

To obtain the specific activity per unit flux the activity values were normalized with the aid of the gold monitor values. There were two monitors for each run, the activities of which were counted to high statistical accuracy. The monitors were water cooled and thus held at constant temperature independent of the temperature of the oven. In addition no inter calibration between the gold foils was necessary as only /3-particles were counted and the foil thickness was large compared to the range of the /3-particles. The error from the monitoring procedure has therefore been considered negligible. Besides the uncertainties mentioned several systematical errors may appear. The Np-activities are obtained after correcting the measured activities for natural and uranium background and fission product activity. The first two are equal in all cases, but the last may be temperature dependent. In order to study this the V-activity from two samples of the same diameter but irradiated at different temperatures (20 C and 600 C) was measured in an energy range about 650 kev. At these energies only the fission products give contributions. The ratio between the 600 C and the 20 C activity was slightly larger than unity (1, 05-0. 04) but the effect is of negligible importance when correcting for the fission product activity. (The fission product activity amounts to only about 3 % of the measured activity.) In the central channel runs lack of space made an effective cooling of the cadmium cover impossible. Its temperature therefore increased somewhat with the temperature of the oven and l-eached a maximum of about 100 C. This temperature increase might change the effective cadmium cut-off slightly, thus changing the l/v absorption. The above mentioned study of the fission product activity at different temperatures, however, indicates that the effect is small and no correction has been made for it. In the reflector runs the cadmium cover was water cooled and the effect was not so pronounced for these runs. As has been pointed out earlier, the flux gradient was large, especially in the reflector runs. Corrections therefore had to be made for the change of the position of the sample relative to the gold monitors. This correction was at most 0.7 %, and its contribution to the total error is estimated to be less than about 0. 3 %. A few of the measured values showed abnormal deviations from the rest of the points.

The reason for this is not clear, but the deviations might be due to dislocations of the samples. A systematical error might also have been caused by resonances in the construction material of the oven. Inside the cadmium cover there were besides the resistance wire for the oven a layer of 0.3 mm of copper for heat reflection, 1.2 mm of iron as canning of the samples and as oven support, and about 5 mm of aluminium oxide as heat insulation. In order to be able to estimate the effect of these materials the oven unit was placed in the fast chopper beam and the transmitted neutron spectrum was studied* Two very small dips were discovered at about 5 ev and 12 ev, the decrease in the transmitted neutron beam being 4 and 6 % respectively in a nax'row energy range. The 12 ev resonance does not coincide 238 with any of the resonance in U and its effect is negligible. For thick uranium samples such as those used in the experiments, the 5 ev resonance will overlap somewhat with the low energy tail of the 6.7 ev resonance in uranium. However, as the dip is only about 4 %, its influence on the Doppler effect in uranium must be very small. Two slightly larger dips (about 10 % decrease in transmission) were found at about 140 ev and 350 ev. For these and higher energies, however, scattering is predominant and shielding effects are not very pronounced. We have therefore considered the influence of the construction material negligible, but an experimental check by varying the amount of this material might have been valuable. Adding the different errors results in an estimated standard deviation of about 0. 7 % for each specific activity. The estimated uncertainty in the temperature coefficients a and /3 depends on this error as well as on the error in the temperature, The error limits are given in Table I. Discussion. The different manners in which the results of earlier measurements have been presented together with the fact that the measurements have been made over different temperature ranges makes intercomparison difficult. In Table II we have, however, made a compilation of published values of 3- Most data concern fairly large diameter rods and there-

Table II. Ref. * a) R.A. Bennett et al. Material U Dimension diam. 3.4 cm Temp, range 20-300 C 0 x 10 4 / C 1.72 t 0.12 *** 4 o fi x 10 V C corr ' 1.60 Method Deduced from experiment giving l/k a Ak^/AT b) Panasyuk (3) c) V. P. Adyasevich et al. (3) d) M.V. Davis (5) e) V. G. Small (8) f) V.B. Egiazarov et al. (2) g) G.W. Rodeback (4) h) R.M. Pearce (7) i) This work j) Theoretically (12) k) ",J. Rosén U u u u u u u u u u? 3. 5 cm 3.4 cm ~ 2.5 cm 2. 8 cm 1.8 cm 2.5 cm 2. 8 cm 3.4 cm 2.8 cm 20 (?) - 100 C 10-80 C 20-300 C 20-250 C 20-450 C 20-650 C 20-300 C 20-650 C 27-327 C 20-300 C 1.4 t 0.25 1.95 t 0.4 1.56 ± 0.12 2.00 t 0.15-0.90 t 0.20 0.90 ± 0.17 0.83 t 0.08** 1.15 (?) 1.65 1.45 1.85 1.60 0.90 0.80 0.95 1.15 1.55 II II II Buckling measurements Danger coefficient Pileoscillator Activation Activation Activation Activation F.C. Engesser (9) This work Theoretically [deduced from (12) by J. Rosén] uo 2 uo 2 uo 2 19 rod clustei of 1.2 cm rods 2.8 cm 2. 8 cm 20-365 C 20-1100 C 20-300 C 1.9 t 0.2** 0.86 t 0.07** 1.95** 1.10** 1.65 Deduced from experiment giving l/k Ak /A T Activation *** private communication corrected for thermal expansion mean values for the temperature range 20-300 C. All values corrected for thermal expansion, assuming a value of 0.16 x 10 / C for the linear thermal expansion coefficient.

il fore our value on the 28 mm rods have been given. Besides the column containing the published values of the temperature coefficients, the table contains a column where these values have if necessary been recalculated to refer to the same temperature range. Most of the data are for a temperature range of about 20-300 C and this range has therefore been chosen for the comparison. The values f) and i) have been corrected by directly using the \ / T-formulas found in the experiments. For the other values no such expressions are given and the corrections are therefore only approximate. The values in the column have also been corrected for the effect of thermal expansion, assuming a value of 0.16 x 10~ / C for the mean linear expansion coefficient in uranium metal. In addition it has been assumed that the given values do not include the l/v-part. This is clearly stated for the values e) g) h) and i) but not for the others. As may be seen from the table, five of the metal measurements are based on reactivity methods and four on activation methods. There seem to be two groups of values, one with a mean value of about 0.9 x 10" / C and the other with a mean around 1.65 x 10" 4 / C. Most of the values belonging to the first group are activation values and most of the others are from reactivity measurements. The same tendency seems to exist for UO 2 as well, though the experimental material is considerably more scarce. It is difficult to find a reason for the discrepancy between the two groups of values. The activation method is more straightforward than the various reactivity methods, and ought to give more reliable results. However, it has been proposed by the Harwell group (private communication) that the use of cadmium in activation experiments might lower the measured temperature coefficient because of screening effects from resonances in the high energy region. Some of the oven material might also cause a similar effect. Part of the discrepancy might be explained by such an effect, but it is difficult to believe that it can account for a factor of almost two. In reactivity measurements in the epithermal region, on the other hand, the effects of scattering, epithermal fissions, probable moderation of the neutrons by the samples., Doppler effects in the oven and canning material, etc., might be considerable. Most of these

12 effects are independent of temperature and the corrections therefore the more important the lower the temperature range over which the measurements have been made. New measurements with some reactivity method over a wider temperature range would therefore be very valuable but the increased experimental complications may be difficult to overcome, In the metal case the lower values agree fairly well with the theoretical value obtained from (12). However, the theoretical calculations have been improved by Rosén, with the result that the volume contribution from the unresolved energy region is raised considerably. This mostly affects the temperature coefficient for large rods, and as indicated in Table II the value for 28 mm rods becomes 1.55 x 10~ / C. Also in the oxide case our activation value for 28 mm rods is lower than the theoretical value calculated by Rosén. The theory behind the calculated values treats the different resonances independently of each other. Thus the effect of overlapping of adjacent resonances is neglected. As overlapping will increase with temperature the present theory overestimates the temperature effect. In addition, the interference between resonance and potential scattering is neglected, the effect of which may also result in an overestimate of the temperature effect. No estimate of the possible magnitude of these effects has been made. The present report is not final. Because of the larger discrepancies in the experimental results we will start some measurements with an oven containing as little material as possible. We will also make some measurements with different thicknesses of cadmium to investigate whether there is any effect caused by the cadmium. EH-d/lG

13 References. (1) E, Creutz, H, Jupnik, E, P. Wigner: "Effect of temperature on the total resonance absorption of neutrons by spheres of uranium oxide". J.AppUPhys. 26_, 276, (1955). (2) M.B. Egiazarov, V.S. Dikarev, V.G. Madeev, Conf.Acad. ~ Sci., USSR, 53, (July 1-5, 1955). (3_) V.P. Adyasevich, I.M. Frank, O.I. Kozinets, F. L. Shapiro, I. V. Shtranikh, K.D. Tolstov: "Measurement of temperature effects in uranium-graphite systems. Conf.Acad. Sci. USSR, 132, (July 1-5, 1955). (4) G.W. Rodeback: "Temperature coefficients of uranium and thorium resonances". NAA-SR-1641, (1956). (5) M.V. Davis: "Resonance Absorption of Neutrons by Uranium ~ Cylinders". J. Appl.Phys. 2jJ, 250, (1957). (6) R.M, Pearce, D.H. Walker: n A direct measurement of uranium ~ metal temperature coefficient of reactivity". Nucl.Sci. Eng, 2, 24, (1957). (7) R,M. Pearce: ' Radial dependence of the Doppler effect in bars ~ of uranium and thorium". AERE R/R 2806, (1959). (8) V.G. Small: "An experimental determination of the increase with temperature of the resonance absorption in uranium and thorium. AERE R/R 2774, (1959). (9) F.C. Engesser: "The metal temperature coefficient for 19 rod clusters of uranium oxide with air coolant, HW-56919. (10) L. Dresner: "Effect of Geometry on resonance neutron absorption in uranium". Nucl.Sci. Eng. 1, 501-510, (1956). (11) L. Dresner: "The effective resonance integrals of U-238 and Th-232". Nucl.Sci. Eng. 1_, 68-79, (1956). (12) F.T, Adler, G.W. Hinman, L. W. Nordheim: "The quantitative evaluation of resonance integrals". GA-350, (1958). (13) S. Brimberg, J. Dahlström: "Calculation of the resonance integral as a function of geometry and temperatures in lattices consisting of heavy water and single rods or clusters of uranium metal or uranium oxide rods. Second Gen.Conf. P/150, (1958). (44) E. Hellstrand: "Measurements of the effective resonance intett gral in uranium metal and oxide in different geometries. J. Appl.Phys. 28, (1957).

14 Legend to the figures Fig 1 Position of the oven in the central channel and in the graphite reflector. Fig Fig 2 3 The oven. RI The ratio -, o diam. metal rods. a function of for the 8 mm Fig Fig Fig 4 5 6 ig 7 The ratio, diam. metal 5T~ i The ratio ~ RI a DT~ O diam. metal roda a s o rods. The ratio = RI 7T~ L o diam. oxide rods. a s S a function of a function r o for the 12.5 mm for the 28 mm for the 8 mm The ratio «- R.I as a function of \ T - \/ T_ for the 12» 5 mm of a function of 1 diam, oxide rods. Fig 8 The ratio -3j- as a function of \ T - \ T Ä for the 28 mm o diam. oxide rods. Fig 9 The ratio -= =- as a function of t C for the 8 mm diam. oxide rods. Fig 10 Fig 11 The temperature coefficient a for metal as a function of S/M. The temperature coefficient a for oxide as a function of S/M.

REACTOR TANK Fig. 1

THERMOCOUPLE LEADS TUBES FOR WATER COOLING OVEN UNIT Au-MONITOR UNIT TUBES FOR ARGON HOLDER Cd SHIELDING JACKET FOR FAST COOLING OF SAMPLE SAMPLE HOLDER THERMOCOUPLE U ENDPIECES fy U SAMPLE Au MONITORS WATER COOLED HOLDER Cd SHIELD CERAMIC TUBE AND STOP 'kanthal WIRE INSULATION -*#> CONCENTRIC HEAT- 'Y REFLECTING Cu ' SHIELDS Fig. 2

RI(T) RI(To) 1100 Uranium metal Diam. 8 mm central channel run reflector run -- theoretical (J. Rosén) 1050 1000 800 t C 15 Fig. 3

1100 Uranium metal Diam 12. 5 mm reflector run theoretical (J. Rosén) Rim 1050 1000

Rim Rift) 1100"1 Uranium metal Diam. 28 mm central channel run -O reflector run -- theoretical (J. Rosén) Fig. 5

reflector run theoretical

reflector run theoretical Rim Rltfo) 1.100 1.050 1.000

1.100 I Uranium oxide Diam. 28 mm central channel run theoretical 1.00Q Fig. 8

1.150 Uranium oxide Diam. 8 mm * > central channel run D reflector run 1100 RKt) RK20) 1.050 1.000 TEMPERATURE "C 1000 Fig. 9 1200

1.0 Uranium metal theoretical, J. Rosén theoretical (12) experimental (2) experimental, this work 0.5 0.1 0.2 0.3 Vn Fig. 10

Uranium oxide theoretical experimental, this work

Additional copies available at the library of AB ATOMENERGI Stockholm - Sweden Affärstryck, Stockholm 1960