The Fluke 66 and 68 Infrared Thermometers

Similar documents
Hot solutions for temperature measurement. Contact and non-contact thermometers from Fluke

566/568. Infrared Thermometers. Getting Started

1551A Ex/1552A Ex Intrinsically Safe Stik Thermometer. The new gold standard of industrial temperature calibration

IR and contact thermometers

Infrared Thermometer Calibration A Complete Guide

Dual laser + type K thermometer INFRARED THERMOMETER

Noncontact Thermometer

InfraRed Thermometer with Laser Pointer

792A AC/DC Transfer Standard

63/66/68. Infrared Thermometers. Users Manual

Infrared Temperature Calibration 101 Using the right tool means better work and more productivity

Infrared Thermometer Model CA879

Infrared Hand-Held Thermometers

792A AC/DC Transfer Standard

Understanding uncertainties associated with the 5128A RHapid-Cal Humidity Generator

IR F ( C) ENGLISH INSTRUCTION MANUAL. Thermometer

HL-800K Infrared Laser Thermometer. -50 C to +800 C (13:1 ratio) User Manual

Infrared / K Thermometer Remote Temperature Measurement ( Non-Contact ) 1327K INSTRUCTION MANUAL

INFRARED THERMOMETER TM0819

Infrared Hand-Held Thermometers

Model ST-616CT. Instruction Manual. Infrared Thermo-Hygrometer. reedinstruments. www. com

IR/Thermistor Pen. Instruction Manual

Manual Dew point scanner PCE-DPT 1

Traceable Big-Digit Type-K Thermometer Big digits are readable from 15 feet away. For additional Type-K probes, see page 41.

INF195 Infrared Thermometer

5730A High Performance Multifunction Calibrator. Extended specifications

Instruction Manual SEFRAM Thermal Camera

Introduction Cautions

Installation guide 862 MIT / MIR

DHS1900 DHS3000 High Temperature Hand Held Infrareds User Manual

EM90 INFRA-RED THERMOMETER & THERMOCOUPLE METER

Designed to go where you work

Non contact temperature measurement

Stick-Style Water-Resistant Infrared Thermometer for Foodservice Applications with 4:1 Distance-to-Sight Ratio Model

Temperature Calibration

Typical pressure measurement uncertainty defined by an FPG8601 Force Balanced Piston Gauge

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

Infrared Thermometer Model: and

INSTRUCTION MANUAL Fax: (503)

User Manual. Stick-Style Water-Resistant Infrared Thermometer with 8:1 Distance-to-Sight Ratio. Model with NIST-Traceable Calibration

Gun-Type Professional Infrared Thermometer MODEL: ST 653. Instruction Manual

D501 and D501-RS. Microscanner D-Series IR Thermometers. no effect. no effect. no effect. no effect no effect

Mini Environmental Quality Meter

473-SHX Dew Point Mirror

473 Dew Point Hygrometer

DIAGNOSTICS NO TOUCH FOREHEAD THERMOMETER

DM70. Hand-held Dewpoint Meter. Truly Fast Response - Superior Long-term Stability

INSTRUCTION MANUAL DTH Fax: (503)

Model DIT-516/517: OPERATING MANUAL

Training Guide. Coastal Environmental Systems, Inc.

Emissivity: Understanding the difference between apparent and actual infrared temperatures

473 Dew Point Hygrometer

High Accuracy High Speed in Your Process

WT-3131A Radio-controlled Analog Clock With Weather Forecast. Instruction Manual

IR-712 IR-712-EUR 12:1 Infrared Thermometer. IR-720 IR-720-EUR 20:1 Infrared Thermometer. IR-730 IR-730-EUR 30:1 Infrared Thermometer.

Determine the Inside Wall Temperature of DSTs using an Infrared Temperature Sensor

OS534E, OS530HRE, OS523E, OS524E OMEGASCOPE

IR-712 IR-720 IR-730

optris LaserSight Operators manual

PTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30

Operator's Manual. optris BR 400. Calibration source

KZPb

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

Monitoring Flammable Vapors and Gases in Industrial Processes

FSUE PA Novosibirsk. PO3-9x24, PO3-9x24-1. Instruction manual

Use of Infrared Thermography for Building Inspection

ea980r Digital Anemometer User Manual

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

Non - Contact Forehead Infrared Thermometer. Care Q7 USER MANUAL - 1 -

Heat stress index. Dewpoint. pressure. altitude

THERMOFOCUS, a technological innovation

E THERMADATA LOGGER Humidity & temperature recording meter

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%

User s Guide OS520, OS520E, OS521, OS522, OS523, OS524. OMEGASCOPE Handheld Infrared Thermometer. omega.com OMEGA

GC005 thru GC600. Wireless Load Cell. Features. Applications. General Description. Load Cell

Data Sheet. Infra-red Temperature Measurement

VIBRATION METER. Instruction Manual.

WISE Damper. Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS

Determine the Inside Wall Temperature of DSTs using an Infrared Temperature Sensor

OS534, OS530L, OS530HR OS523, OS524 OMEGASCOPE

4HP13 PRODUCT SPECIFICATIONS 13 SEER SPLIT SYSTEM HEAT PUMP WARRANTY

TM360 TEMP-SEEKER PRECISION THERMO-PSYCHROMETER OPERATION MANUAL

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202

Data Sheet / Instructions. Dewpoint MeterO

VIBRATION METER Acceleration & Velocity Model : VB-8201HA

Introduction to Blackbody Sources

INFRARED THERMOMETER Model : TM-959

HYGRASGARD KFF KFTF HYGRASGARD AFF AFTF HYGRASGARD AFF - LC AFTF - LC

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

Thermal anemometer. We measure it. testo 405. Flow velocity measuring instrument with temperature measurement

INSTRUCTION MANUAL. DHS24X, DHS24XL, DHS24L DHS26X, DHS26XL, DHS26XT, DHS26L DHS28X, DHS28XL, DHS28XT, DHS 29XT, DHS 35XT And all DHSA Models

CALYS 80P. Field pressure calibrator with high accuracy 0.01%

Vaisala DRYCAP Hand-Held Dewpoint Meter DM70. Fast Response - Low Maintenance

User s Guide. Shown with Built-in Laser Sighting. OS531, OS532, OS533, OS534 OMEGASCOPE Handheld Infrared Thermometer

Temperature control for Varian Cary line of UV/Vis Spectrophotometers and the Eclipse Fluorometer

INFRARED TEMPERATURE SENSORS OPERATION AND SELECTION

RT-6 Riflescopes. User Guide

Transcription:

The Fluke 66 and 68 Infrared Thermometers Non-contact temperature measurement Technical ata The professional s diagnostic tool The Fluke 66 and Fluke 68 non-contact thermometers are the ideal professional diagnostic tools for HVAC technicians performing room balance checks, electricians evaluating electrical connections and auto mechanics diagnosing catalytic converters. This handheld portable tool enables professionals to research heating and ventilation problems, monitor the status of electrical motors and electrical panels and diagnose car malfunctions with ease. They measure surface temperatures, helping to quickly locate potential blockages or malfunctioning systems reducing work time and improving performance. The 60 series thermometers feature: Laser guided sighting system for easy targeting with 1 % accuracy. 12-point data logging. Advanced optics to measure smaller targets at greater distances. Adjustable emissivity for more accurate temperature measurements. electable MAX, MIN, IF and AVG functions that display values instantly with Hi/Lo Alarm. Temperatures up to 760 ºC (1400 ºF) (68, 68I). Intrinsically afe model available (68I). * Optical resolution The laser sighting system guides measurements to the right target and indicates the approximate center of the measurement area. (: = distance to spot using 90 % encircled energy at focal point). The 68I * model is available for the noncontact temperature monitoring needs of potentially explosive or flammable environments. *Approved by Factory Mutual Research, a UA organization, for use in hazardous locations. The 68I approval does not apply to atmosphere containing coal dust, grain dust, metal dust or fibers. Check your national and company regulations to determine if this approval is appropriate for your situation. (68I only)

pecifications Fluke 66 Fluke 68/68I * Temperature range -32 to 600 C -32 to 760 C (-25 to 1100 F) (-25 to 1400 F) Accuracy -32 to -26 C (-25 to -15 F): ±3 C (±5 F) (assumes ambient -26 to -18 C (-15 to 0 F): ±2.5 C (±4 F) operating temperature -18 to 23 C (0 to 73 F): ±2 C (±3 F) of 23 C [73 F]) For targets above 23 C (73 F): ±1 % or reading or ±1 C (±2 F), whichever is greater Repeatability ±0.5 % or ±1 C (±2 F), whichever is greater Response time 0.5 second (95 % of reading) pectral response 8 to 14 µm Emissivity igitally adjustable emissivity (from 0.1 to 1.0 by 0.01) Ambient operating temp. 0 to 50 C (32 to 120 F) Relative humidity 10 to 90 % RH non-condensing, at <30 C (86 F) ambient torage temperature -20 to 60 C (-13 to 158 F) without battery imensions 200 x 160 x 55 mm (8 x 6 x 2 in.) Weight 320 g (11 oz.) Power 9 V alkaline or NiCd battery Batter life (alkaline) 20 hours with laser and backlight on 50 % 40 hours with laser and backlight off Laser sighting (Class II) Offset single point laser point Typical distance to target 5 m (15 ft.) 8 m (25 ft.) istance to pot (:) 30:1 at focus point 50:1 at focus point MIN, MAX, AVG, IF Temperature display ata logging 12 points Probe jack isplay hold (7 seconds) Hi/Low alarm LC backlit Temperature display C or F selectable isplay resolution 0.1 C (0.1 F) Hard carrying case Locking trigger Tripod mounting 6.35 mm (.25 in.) 20 UNC threading Warranty 2 years, conditional * Approved by Factory Mutual Research for use in hazardous locations. : = 30:1 at focal point 0.9" @ 12" 1.2" @ 36" 2.5" @ 60" Use the Fluke 66 within 5 m (15 ft.) of the intended target. At greater distances, the measured area will be larger (approximately the distance divided by 30). : = 50:1 at focal point 0.8" @ 12" 0.7" @ 36" 1.7" @ 60" Use the Fluke 68 and 68I within 8 m (25 ft.) of the intended target. At greater distances, the measured area will be larger (approximately the distance divided by 50). Ordering information Fluke 66 Infrared Thermometer Fluke 68 Infrared Thermometer Fluke 68I Infrared Thermometer Included Optional accessories: RT temperature probe (standard w/68i) 32 ºC to 260 ºC (-25 ºF to 500 ºF) Non-contact thermometer holster Fluke. Keeping your world up and running. Fluke Corporation PO Box 9090, Everett, WA UA 98206 Fluke Europe B.V. PO Box 1186, 5602 B Eindhoven, The Netherlands For more information call: In the U..A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa +31 (40) 2 675 200 or Fax +31 (40) 2 675 222 In Canada (800) 36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com 2005 Fluke Corporation. All rights reserved. Printed in U..A. 6/2005 2153543 -U-N Rev C *Included w/68i tandard Feature (68I only) Factory Mutual Research Intrinsically afe approval, including probe (Intrinsically safe, Class I ivision 1 Groups A, B, C, Class I, Zone 0, AEx ia IIC, T4 at 50 ºC when used with 9V alkaline battery.) Groups A, B, C, refers to: Acetylane, Hydrogen, Ethylene and Propane.

The Fluke 63 Infrared Thermometer Non-contact temperature measurement Technical ata The professional s diagnostic tool The Fluke 63 non-contact thermometer is the ideal professional diagnostic tool for quick and accurate temperature measurements. This handheld portable tool enables professionals to research heating and ventilation problems, monitor the status of electrical motors and electrical panels and diagnose car malfunctions with ease. Features include: Expanded measurement range up to 535 C (999 F) High-resolution optics High accuracy: 1 % and repeatability: 0.5 % MAX temperature display Laser targeting Backlit display The Fluke 63 thermometer makes troubleshooting quick and easy. The single dot laser sighting system guides measurements to the right target and in less than a second, the large temperature display provides current and MAX surface temperatures. The locking trigger and tripod mount capability allow for continuous temperature monitoring. Optical resolution The single dot laser sighting system guides measurements to the right target and indicates the approximate center of the measurement area. : (distance to spot using 90 % encircled energy at focal point.) : = 12:1 at focal point 1.5" @ 12" 3" @ 36" 5.3" @ 60" Use the Fluke 63 within six feet of the intended target. At greater distances, the measured area will be larger (approximately the distance divided by 12). The Fluke 63 offset single-point laser indicates the approximate center of the measurement area.

pecifications Temperature range -32 to 535 C (-25 to 999 F) Accuracy -32 to -26 C (-25 to -15 F): ±3 C (±5 F) (Assumes ambient -26 to -18 C (-15 to 0 F): ±2.5 C (±4 F) operating temperature -18 to 23 C (0 to 73 F): ±2 C (±3 F) of 23 C [73 F]) 23 to 510 C (73 to 950 F): ±1 % of reading or ±1 C (±2 F), whichever is greater Above 510 C (950 F): ±1.5 % of reading Repeatability ±0.5 % or ±1 C (±2 F), whichever is greater Response time 0.5 second (95 % of reading) pectral response 8 to 14 µm Emissivity Pre-set at 0.95 Ambient operating temp 0 to 50 C (32 to 120 F) Relative humidity 10 to 90 % torage temperature -20 to 60 C (-13 to 158 F) without battery imensions 200 x 160 x 55 mm (8 x 6 x 2 in.) Weight 320 g (11 oz.) Power 9 V alkaline or NiCd battery Batter life (alkaline) 10 hours with laser and backlight on 40 hours with laser and backlight off Typical distance to target Up to 2 m (6 ft.) istance to pot ratio 12:1 Max temperature display isplay hold (7 seconds) LC backlit Temperature display C or F selectable isplay resolution 0.2 C (0.5 F) Hard carrying case Tripod mounting Warranty 2 years, conditional Optional accessories: Non-contact thermometer holster Ordering information Fluke 63 Infrared Thermometer Included Fluke. Keeping your world up and running. Fluke Corporation PO Box 9090, Everett, WA UA 98206 Fluke Europe B.V. PO Box 1186, 5602 B Eindhoven, The Netherlands For more information call: In the U..A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa (31 40) 2 675 200 or Fax (31 40) 2 675 222 In Canada (800) 36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com 2005 Fluke Corporation. All rights reserved. Printed in U..A. 4/2005 2150511 -ENG-N Rev B

The Fluke 62 Mini Infrared Thermometer Non-contact temperature measurement Non-contact diagnostic tool The Fluke 62 Mini infrared thermometer is a non-contact diagnostic tool for quick basic temperature checks in applications where a technician is close to the target object. imple to use, the Fluke 62 Mini enables technicians to discover temperature discrepancies before they become problems. Professionals can troubleshoot maintenance problems by measuring surface temperatures of motors, electrical equipment, insulated walls and pipes, heating, ventilation and refrigeration systems all from a safe distance. Features include: Temperature measurement range up to 500 ºC (932 ºF) High-resolution optics Accurate to within ± 1 % of reading MAX temperature display Laser sighting Backlit display Compact and convenient, the Fluke 62 Mini thermometer makes troubleshooting quick and easy and is useful anywhere that temperature plays a role in product quality or equipment maintenance. The single dot laser indicates the center of the target; the large temperature display provides current and MAX surface temperatures. Optical resolution Use the Fluke 62 Mini within six feet of the intended target. At greater distances, the measured area will be larger (approximately the distance divided by 10). The Fluke offset single-point laser indicates the approximate center of the measurement area. Technical ata 25mm @ 250mm 50mm 500mm @ 100mm @ 1000mm : = 10:1 1" @ 10" 2" @ 20" 4" @ 40" The single dot laser system indicates the approximate center of the measurement area.

pecifications Measurement range Accuracy Repeatability Emissivity Response time istance to spot size pectral range isplay resolution isplay hold (7 seconds) LC backlit Temperature display Ambient operating range Relative humidity Typical distance to target (spot) Laser class II Weight/dimensions Power Battery life (alkaline) torage temperature Options/accessories: Warranty: -30 C to 500 C (-20 F to 932 F) 10 ºC to 30 ºC (50 ºF to 86 ºF): ± 1 ºC (2 ºF) Outside 10 ºC to 30 ºC (50 ºF to 86 ºF): ± 1.5 ºC (3 ºF) or ± 1.5 % of reading, whichever is greater ±0.5 % of reading or < ±1 C (±2 F), whichever is greater Preset 0.95 < 500 mec 10:1 calculated @ 80 % energy 6.5 18 microns thermopile detector 0.2 C (0.5 F) C or F selectable 0 to 50 C (32 to 120 F) 10-90 % RH non-condensing, @ up to 30 C (86 F) Up to 2 m (6 ft) ingle offset laser 200 g (7 oz); 152 x 101 x 38 mm (6 x 4 x 1.5 in) 9 V Alkaline battery (included) 12 hours -20 ºC to 65 ºC (-4 ºF to 150 ºF) without battery Includes protective boot and storage holster 2 years (conditional) Ordering information Fluke 62 Mini Infrared Thermometer Included: torage Pouch Fluke. Keeping your world up and running. Fluke Corporation PO Box 9090, Everett, WA UA 98206 Fluke Europe B.V. PO Box 1186, 5602 B Eindhoven, The Netherlands For more information call: In the U..A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa (31 40) 2 675 200 or Fax (31 40) 2 675 222 In Canada (800) 36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com/ 2005 Fluke Corporation. All rights reserved. Printed in U..A. 4/2005 2437622 -U-N Rev A