Infrared Hand-Held Thermometers

Similar documents
Infrared Hand-Held Thermometers

Thermal Mass Flow Meter for Gases

Non contact temperature measurement

HL-800K Infrared Laser Thermometer. -50 C to +800 C (13:1 ratio) User Manual

Operating Instructions for Digital Manometer. Model: MAN-SD

DVZ. Vortex Flowmeter Compact. for low viscosity liquids. Range: l/min. Accuracy: ±2.5% of full scale. p max : 20 bar; t max : 80 C

Hot solutions for temperature measurement. Contact and non-contact thermometers from Fluke

InfraRed Thermometer with Laser Pointer

Oscillation Flow Meter for Gases

Stick-Style Water-Resistant Infrared Thermometer for Foodservice Applications with 4:1 Distance-to-Sight Ratio Model

DHS1900 DHS3000 High Temperature Hand Held Infrareds User Manual

IR F ( C) ENGLISH INSTRUCTION MANUAL. Thermometer

IR 40. Non-Contact Infrared Temperature Sensor/Transmitter. Temperature Range: 0~1000

User Manual. Stick-Style Water-Resistant Infrared Thermometer with 8:1 Distance-to-Sight Ratio. Model with NIST-Traceable Calibration

Model ST-616CT. Instruction Manual. Infrared Thermo-Hygrometer. reedinstruments. www. com

MIK. Electromagnetic Flowmeter Compact. for conductivity liquids. Range from liquids, acids and caustic solutions:

INFRARED THERMOMETER TM0819

Industrial Resistance Thermometers according to DIN Model MWD

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

The Fluke 66 and 68 Infrared Thermometers

INFRARED THERMOMETER Model : TM-959

IR 80-H. Non-Contact Infrared Temperature Sensor/Transmitter. Temperature Range: 500~1700

Infrared Thermometer Model CA879

DOG-1/-3. Oscillation Flowmeter. for gases. Measuring ranges: m 3 /h air : 120 C. p max. : PN 40; t max

Dual laser + type K thermometer INFRARED THERMOMETER

Infrared / K Thermometer Remote Temperature Measurement ( Non-Contact ) 1327K INSTRUCTION MANUAL

473 Dew Point Hygrometer

MIK. Electromagnetic Flowmeter Compact. for conductivity liquids

473 Dew Point Hygrometer

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

One-hand ph/temperature measuring instrument

Introduction Cautions

DM70. Hand-held Dewpoint Meter. Truly Fast Response - Superior Long-term Stability

566/568. Infrared Thermometers. Getting Started

Thermometers. Applications

ABB temperature measurement Radiation thermometry. Measurement made easy. Process temperature measurement practice--non-contacting

Traceable Big-Digit Type-K Thermometer Big digits are readable from 15 feet away. For additional Type-K probes, see page 41.

THERMOFOCUS, a technological innovation

Introduction to Fourier Transform Infrared Spectroscopy

D501 and D501-RS. Microscanner D-Series IR Thermometers. no effect. no effect. no effect. no effect no effect

Introduction to Fourier Transform Infrared Spectroscopy

473-SHX Dew Point Mirror

Acceleration/Velocity/Displacement VIBRATION METER

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

Analog - Digital multimeters

Full Metal Variable Area Flow Meter and Counter

Instruction Manual SEFRAM Thermal Camera

ph/redox Measurement CPM 280

optris LaserSight Operators manual

HANDHELD GAS ANALYZER DELTA 65

Ion-Chamber Survey Meter OD-02

ISEmax CAM40/CAS40. Technical Information

Infrared Sensors. Operators manual thermometer CSL-SF50 / CSLM-2HSF300

Lever-type Dial Test Indicators

Lever-type Dial Test Indicators

THM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist

Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202

Use of Infrared Thermography for Building Inspection

W 9 L: Laser photoelectric switches: small, light and reliable

DIGITAL THERMOMETER OPERATOR S MANUAL

HYGRASGARD KFF KFTF HYGRASGARD AFF AFTF HYGRASGARD AFF - LC AFTF - LC

TSK. Flap-Type Flowmeter. Range: to GPM Accuracy: ± 2.5% of Full Scale P max. : 580 PSI T max

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%


VIBRATION METER Acceleration & Velocity Model : VB-8201HA

Product Data. Brüel & Kjær B. Sound Intensity Calibrator Type 3541

PHOENIX CONTACT - 04/2016. Features

PULSE TOTAL STATION GPT-3000(L)N SERIES

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

EM90 INFRA-RED THERMOMETER & THERMOCOUPLE METER

The Plus for your lab!

INFRARED TEMPERATURE SENSORS OPERATION AND SELECTION

Year 10 End of Year Examination Revision Checklist

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

610,- KERN ADB. Analytical balances. Quick-Finder Analytical balances. Large glass draught shield with 3 sliding doors

The Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows:

3URGXFWLQIRUPDWLRQ 5HVHUYDWLRQRISURSHUW\ULJKWV

Operator s Manual. optris CSlaser. LT/ hs LT/ 2M/ G5. Infrared-thermometer

ED 701 General Industry Pressure Transmitter

S95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation

The New Quintix. Intuitive application guideance. Maximum accuracy at all time. Easy cleaning. Plug & Work connectivity to printer or computer

Remain Calm, Target Accurately

VictoryJustifiesEverything 2012ProductCatalog

RoHS. Versatile. X g. X 2 e

VIBRATION TACHOMETER OPERATION MANUAL. 3 in 1. Model : VT Your purchase of this

ADI 2040 Process Analyzer

Preview from Notesale.co.uk Page 1 of 38

Xenics Presentation. A 25 minute crash course in Thermography

REQUEST FOR QUOTATION (RFQ) FOR PROCUREMENT OF THERMO HYGROMETER -UNDP GLOBAL FUND

Optical Fiber Strain/Loss Analyzer AQ8602/8602B

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.

One-Year Limited Warranty

D i s t a n ce Sensor DS 60

WT 27 L-2 Laser Photoelectric proximity switches, background suppression -- DC. Dimensional drawing Adjustments possible WT 27L-2F 430

Model TS318-11C55 Thermopile Sensor

More Precision. Non-contact IR temperature sensors

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

GT-510/510L series Instruction Manual

Noncontact Thermometer

Transcription:

Infrared Hand-Held Thermometers measuring monitoring analysing Model: TIR-H... Measuring range from -2 to 5 C to -32 to 9 C Measuring accuracy: ±1% to ± 2% of measured value Option: analogue output, RS 232, data memory, laser aiming light, statistical functions Non-contact measurement Simple operation 1/34/Ko /1 KOBOLD offices exist in the following countries: ARGENTINA, AUSTRIA, BELGIUM, BRAZIL, CANADA, CHINA, FRANCE, GERMANY, GREAT BRITAIN, ITALY, MEXICO, NETHERLANDS, PERU, POLAND, SWITZERLAND, USA, VENEZUELA KOBOLD Messring GmbH Nordring 22-24 D-65719 Hofheim/Ts. (6192) 299- Fax (6192) 23398 E-mail: info.de@kobold.com Internet: www.kobold.com Model: TIR-H... 43

Non-Contact Temperature Measurement with Infrared Radiation Application The series TIR infrared measuring instruments measure the surface temperature of the most varied materials and liquids in seconds in a non-contacting and non-interacting way. Due to state-of-the-art microprocessor technology, the devices are compact and easy to operate. The measuring position is targeted with a laser pointer or an optical sight, the trigger is pressed and the measurement result is read on a large display.. Method of operation The non-contact temperature measurement is based on the physical effect that every physical object emits electromagnetic radiation when heated. The radiated energy and its characteristic wavelength depends on the temperature of the surface of the target. I U A D µc D Interface A /4...2 ma RS 232 / RS 485 DC DC 24 V DC The heat radiation can be seen with the naked eye above approximately 55 C. The target is then said to glow. Radiation below the light spectrum of red light is called infrared radiation. Infrared measuring systems are able to concentrate infrared radiation with a suitable system of lens and to convert it to electrical signals. The microprocessor receives the radiation characteristics of the target in the form of emittance. The microprocessor outputs the measured value in digital form to the display or converts it to an analogue signal. Advantages Unbeatable accuracy Non-contact measurement, thus short measuring time and no frictional heat Safe operation, because of distance from danger zone Isolated measuring by utilizing infrared radiation, also on surfaces that are bad conductors of heat. Measurements at places that are difficult to access Measurements on rotating and moving objects Long-term stable, zero-drift measurements Maintenance-free Design Due to the rapid pace of technological development, highly sensitive and stable infrared detectors are available, with which low temperatures (even well below freezing) can be determined by non-contacting means. The downstream microprocessor-based electronics linearizes the electrical signals and mathematically compensated for material and surface-dependant influences with the set emittance. Device programme Battery-powered hand-held devices Model TIR-HA -3 to +3 C emittance.5 to 1. (adjustable) Model TIR-HN -2 to +5 C to -3 to +9 C emittance.1 to 1. (adjustable) Options: laser, RS 232, data memory statistical functions 44 www.kobold.com 1 /34/Ko/1

Reasonably-Priced Infrared Hand-Held Thermometers for Non-Metallic Surfaces Special features Small dimensions, negligible weight LED positioning aid Multi LCD indicator Adjustable emittance Continuous temperature display Hold function Automatic switch off Automatic battery monitor Reasonably-priced version Technical Details Changeover: ON/E/HOLD Measuring ranges: -3. C to 99.9 C resolution.1 K 1 C to 3 C resolution 1 K Range selection: automatic Measuring accuracy*: -3 to -1 C ± 3. C -9 to +2 C ± 2. C +21 to +4 C ± 1. C +41 to +1 C ± 1.5 C +11 to +2 C ± 2. C +21 to +3 C ± 3. C *Referred to a reference device with an emittance greater than.99 and an ambient temperature of 25 C Diameter of measuring dot: approximately 5 mm at 4 mm Emittance:.5 to 1. Display: LCD display, 3-segment Overrange indication: 3 C flashing at temperatures greater than 3 C -3 C flashing at temperatures less than -3 C Function temperature: 1 C to 4 C (short-term measurements outside the specification are possible) Battery type: 9 V alkaline ( IEC 6LR61) Battery life: approx. 1 measurements Weight: 166 g / including battery Dimensions: 18 x 52 x 45 mm L x B x H Order Details Model TIR-HA3 Description Infrared hand thermometer -3. to +3. C including 9 V battery Applications Plastics, rubber, food, paper, textiles, paints, glass, liquids, asphalt, wood Diameter of measuring dot Diameter of measuring dot (mm) 5 17 4 6 8 1 1/34/Ko /1 4 1 2 3 4 5 Distance between sensor and object (mm) For larger distances (>,5 m) : Dot diameter = distance /5 www.kobold.com 45

Infrared Hand-Thermometers for Non-Metallic Surfaces Description The TIR Infrared hand-held thermometers are universal measuring instruments for non-contact temperature measurement. They are remarkable for the following special features: Convenient one-hand operation and display with pistol grip Ergonomic design Large multifunction display Laser aiming light for marking measuring dot (optional) Many computer functions Automatic display illumination Adjustable emittance Locking switch for continuous mode Order Details (Example: TIR-HN4 D L) Technical Details TIR-HN4.../5.../6 Accuracy ( with Tu=23 C, ε=1): TIR-HN4: 2 % of measured value or 2 C TIR-HN5/...6: 1% of measured value or 1 C Repeatability: TIR-HN4: 1 % of measured value or 1 C TIR-HN5/...6:.5% of measured value or 1 C Response time (t9): 3 ms Emittance:.2-1.95 (TIR-HN4 factory set) Display illumination: automatic Display resolution: 1 C Temperature indication: 3 digits, C/ F switchable (TIR-HN4 factory set) Operating temperature to 55 C Storage temperature - 2 to 7 C Supply: battery 9 V Block Battery life: approx. 8 h / 25 h (with/without laser) Math. functions: MAX, MIN, AVG switchable MAX with TIR-HN4 Hold function: 1 s Measuring dot marking: laser aiming light laser category 2 Protection type: IP 2 Case material ABS Dimensions of housing: 25 x 13 x 45 mm (H x L x W) Tripod thread: UNC 1/4" Weight: 34 g (with battery) Applications: Plastics Rubber Paper Textiles Liquids Paints Asphalt Wood Glass Food No bright metal Model Measuring range Relation of distance Fittings Infrared detector Thermopile TIR-HN4... TIR-HN5... TIR-HN6... -32 to +4 C -32 to +5 C -32 to +6 C..D..=1 : 1; Ø 2 mm..g..=1 : 15; Ø 8 mm..h..=1 : 3; Ø 15 mm L=with laser Spectral range 8-14 µm (no influence of steam and CO 2 ) 46 www.kobold.com 1 /34/Ko/1

Infrared Hand-Thermometers for Higher Temperatures and Non-Metallic Surfaces with Data Memory Description The TIR Infrared hand-held thermometers are universal measuring instruments for non-contact temperature measurement. They are remarkable for the following special features: Convenient one-hand operation and display with pistol grip Ergonomic design Large multifunction display Laser aiming light for marking measuring dot Many computer functions Automatic display illumination RS232 interface or analogue output Adjustable emittance Technical Details TIR-HNR... Accuracy (with Tu=23 C, ε=1) : Repeatability: Temperature coefficient: Response time (t9): Emittance: Display illumination: 1 % of measured value ± 1 K ±2 C for measuring temperature under -1 C ±.5% of measured value ±1 K ±.3%/ C of measured value 15 ms.2 1 adjustable automatic Display resolution:.1 C: -3 C to 9 C.1 F: -22 F to 999.9 F 1 F: 1 F to 1652 F Temperature indication: C/ F switchable 3 digits Operating temperature: -18 to 55 C Storage temperature: -2 to 7 C Supply: battery 9 V block (IEC GLR61) Math. function: MAX, MIN, AVG, T Hold function: 1 s Data memory: 25 measured values with all parameters Interface: RS 232, 96 BAUD Measuring dot marking: laser aiming light marks the centre of the measuring field, laser category 2 Alarm function: HI alarm, LO alarm, adjustable Analogue output: 1 mv/ C or 1 mv/ F Charging socket: for connecting a charger for NC battery Battery life: 4 hours without laser Weight: 47 g Order Details (Example: TIR-HNR 9 E LR) Model Measuring range Optics Fittings Infrared detector Applications Plastics, TIR-HNR8... TIR-HNR9... -32 to +8 C -32 to +9 C..E= optics 1 mm (1:5) Ø 2 mm standard..b=auxiliary optics 1 mm (1:5) Ø 2 mm LR=with laser, RS 232 without memory LD=with laser, RS 232 memory, software charging socket Thermopile Spectral range: 8-14 µm (no influence of steam and CO 2 ) Rubber, Paper, textiles, Liquids, Paints, Asphalt, wood, Glass, Food No bright metal 1/34/Ko /1 www.kobold.com 47

Infrared Hand-Thermometers for Higher Temperatures and Non-Metallic Surfaces with Data Memory Size of measuring dot for hand-held measuring instruments model TIR-HN4...TIR-HN6 TIR-HN6 15 33 24 81 5 1 2 The laser aiming light is 2 mm above the centre of the measuring dot. TIR-HN5 8 66 37 14 5 1 2 TIR-HN4 22 2 68 1 6 1 2 Size of measuring dot for hand-held measuring instruments model TIR-HNR8...TIR-HNR9 With attachment lens 2 2 2 6 2 2,2 47 mm 5 1 2 1 3 mm The laser aiming light marks the centre of the measuring dot. Accessories for infrared hand-held measuring instruments TIR-ZH 1 TIR-ZH 2 TIR-ZH 3 TIR-ZH 4 TIR-ZH 5 Battery for TIR-HNR Charger for TIR-HNR Carrying case for TIR-HN... RS-232 Transmission cable for printer Online software model with transmission cable 48 www.kobold.com 1 /34/Ko/1