BioMechanics and BioMaterials Lab (BME 541) Experiment #5 Mechanical Prosperities of Biomaterials Tensile Test

Similar documents
ME 2570 MECHANICS OF MATERIALS

NORMAL STRESS. The simplest form of stress is normal stress/direct stress, which is the stress perpendicular to the surface on which it acts.

Measurement of Bone Strength and Stiffness using 3-Point Bending

MECE 3321 MECHANICS OF SOLIDS CHAPTER 3

Elastic Properties of Solids (One or two weights)

five Mechanics of Materials 1 ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS SUMMER 2017 lecture

ME 243. Mechanics of Solids

4.MECHANICAL PROPERTIES OF MATERIALS

Elastic Properties of Solid Materials. Notes based on those by James Irvine at

MATERIALS FOR CIVIL AND CONSTRUCTION ENGINEERS

Tensile stress strain curves for different materials. Shows in figure below

Structural Metals Lab 1.2. Torsion Testing of Structural Metals. Standards ASTM E143: Shear Modulus at Room Temperature

[5] Stress and Strain

Experiment Two (2) Torsional testing of Circular Shafts

Outline. Tensile-Test Specimen and Machine. Stress-Strain Curve. Review of Mechanical Properties. Mechanical Behaviour

Stress-Strain Behavior

Elastic Properties of Solids Exercises I II for one weight Exercises III and IV give the second weight

Stress Strain Elasticity Modulus Young s Modulus Shear Modulus Bulk Modulus. Case study

The objective of this experiment is to investigate the behavior of steel specimen under a tensile test and to determine it's properties.

Chapter 7. Highlights:

High Tech High Top Hat Technicians. An Introduction to Solid Mechanics. Is that supposed to bend there?

AERO 214. Lab II. Measurement of elastic moduli using bending of beams and torsion of bars

Theory at a Glance (for IES, GATE, PSU)

Samantha Ramirez, MSE. Stress. The intensity of the internal force acting on a specific plane (area) passing through a point. F 2

Introduction to Engineering Materials ENGR2000. Dr. Coates

Load, Stress and Strain Chapter 30

STRAIN GAUGES YEDITEPE UNIVERSITY DEPARTMENT OF MECHANICAL ENGINEERING

1.103 CIVIL ENGINEERING MATERIALS LABORATORY (1-2-3) Dr. J.T. Germaine Spring 2004 LABORATORY ASSIGNMENT NUMBER 6

6.4 A cylindrical specimen of a titanium alloy having an elastic modulus of 107 GPa ( psi) and

Mechanical properties 1 Elastic behaviour of materials

Mechanics of Materials

ME 354, MECHANICS OF MATERIALS LABORATORY COMPRESSION AND BUCKLING

Mechanical Properties of Materials

STRENGTH OF MATERIALS-I. Unit-1. Simple stresses and strains

STANDARD SAMPLE. Reduced section " Diameter. Diameter. 2" Gauge length. Radius

9 MECHANICAL PROPERTIES OF SOLIDS

1 332 Laboratories 1. 2 Computational Exercises 1 FEA of a Cantilever Beam... 1 Experimental Laboratory: Tensile Testing of Materials...

This guide is made for non-experienced FEA users. It provides basic knowledge needed to start your fatigue calculations quickly.

ENSC387: Introduction to Electromechanical Sensors and Actuators LAB 3: USING STRAIN GAUGES TO FIND POISSON S RATIO AND YOUNG S MODULUS

COURSE TITLE : THEORY OF STRUCTURES -I COURSE CODE : 3013 COURSE CATEGORY : B PERIODS/WEEK : 6 PERIODS/SEMESTER: 90 CREDITS : 6

UNIT I SIMPLE STRESSES AND STRAINS

CHAPTER 3 THE EFFECTS OF FORCES ON MATERIALS

22 Which of the following correctly defines the terms stress, strain and Young modulus? stress strain Young modulus

EDEXCEL NATIONAL CERTIFICATE/DIPLOMA MECHANICAL PRINCIPLES AND APPLICATIONS NQF LEVEL 3 OUTCOME 1 - LOADING SYSTEMS TUTORIAL 3 LOADED COMPONENTS

Mechanics of Materials Primer

Circular Motion and Centripetal Force

Chapter 6: Mechanical Properties of Metals. Dr. Feras Fraige

1.105 Solid Mechanics Laboratory Fall 2003 Experiment 3 The Tension Test

Lab Exercise #5: Tension and Bending with Strain Gages

12/8/2009. Prof. A.K.M.B. Rashid Department of MME BUET, Dhaka

FIS Specifications for Flex Poles (Edition May 2008) Original Text: German

CHAPTER 6 MECHANICAL PROPERTIES OF METALS PROBLEM SOLUTIONS

ME 207 Material Science I

PERIYAR CENTENARY POLYTECHNIC COLLEGE PERIYAR NAGAR - VALLAM THANJAVUR. DEPARTMENT OF MECHANICAL ENGINEERING QUESTION BANK

MECHANICS OF SOLIDS. (For B.E. Mechanical Engineering Students) As per New Revised Syllabus of APJ Abdul Kalam Technological University

Module III - Macro-mechanics of Lamina. Lecture 23. Macro-Mechanics of Lamina

MAE 322 Machine Design. Dr. Hodge Jenkins Mercer University

TINIUS OLSEN Testing Machine Co., Inc.

Reliable Test Results

N = Shear stress / Shear strain

ANSYS Mechanical Basic Structural Nonlinearities

Instrumented Impact Testing

The University of Melbourne Engineering Mechanics

σ = F/A ε = L/L σ ε a σ = Eε

Sean Carey Tafe No Lab Report: Hounsfield Tension Test

Chapter Two: Mechanical Properties of materials

Physical Properties Testing Technical Bulletin

Medical Biomaterials Prof. Mukesh Doble Department of Biotechnology Indian Institute of Technology, Madras. Lecture - 04 Properties (Mechanical)

1.105 Solid Mechanics Laboratory

MECHANICS OF MATERIALS

EDEXCEL NATIONAL CERTIFICATE/DIPLOMA SCIENCE FOR TECHNICIANS OUTCOME 1 - STATIC AND DYNAMIC FORCES TUTORIAL 3 STRESS AND STRAIN

Predicting Fatigue Life with ANSYS Workbench

Experiment C-10 Titration of a Strong Acid and a Strong Base

INTRODUCTION (Cont..)

Lab Exercise #3: Torsion

Mechanical Design in Optical Engineering. For a prismatic bar of length L in tension by axial forces P we have determined:

Strength of Materials (15CV 32)

There are three main types of structure - mass, framed and shells.

Static Equilibrium; Elasticity & Fracture

Experiment Five (5) Principal of Stress and Strain

BIAXIAL STRENGTH INVESTIGATION OF CFRP COMPOSITE LAMINATES BY USING CRUCIFORM SPECIMENS

5. STRESS CONCENTRATIONS. and strains in shafts apply only to solid and hollow circular shafts while they are in the

PES Institute of Technology

DET: Technological Studies Structures and Materials Higher

Statics Principles. The laws of motion describe the interaction of forces acting on a body. Newton s First Law of Motion (law of inertia):

Mechanics of Solids. Mechanics Of Solids. Suraj kr. Ray Department of Civil Engineering

QUESTION BANK SEMESTER: III SUBJECT NAME: MECHANICS OF SOLIDS

, causing the length to increase to l 1 R U M. L Q P l 2 l 1

Chapter 5. Vibration Analysis. Workbench - Mechanical Introduction ANSYS, Inc. Proprietary 2009 ANSYS, Inc. All rights reserved.

Torsion/Axial Illustration: 1 (3/30/00)

ESE TOPICWISE OBJECTIVE SOLVED PAPER I

COMPLEX STRESS TUTORIAL 4 THEORIES OF FAILURE. You should judge your progress by completing the self assessment exercises.

X has a higher value of the Young modulus. Y has a lower maximum tensile stress than X

UNIVERSITY PHYSICS I. Professor Meade Brooks, Collin College. Chapter 12: STATIC EQUILIBRIUM AND ELASTICITY

Video lecture on Engineering Fracture Mechanics, Prof. K. Ramesh, IIT Madras 1

Homework No. 1 MAE/CE 459/559 John A. Gilbert, Ph.D. Fall 2004

STRESS, STRAIN AND DEFORMATION OF SOLIDS

Appendix A: Laboratory Report Format

INTRODUCTION TO STRAIN

Solid Mechanics Chapter 1: Tension, Compression and Shear

Transcription:

BioMechanics and BioMaterials Lab (BME 541) Experiment #5 Mechanical Prosperities of Biomaterials Tensile Test Objectives 1. To be familiar with the material testing machine(810le4) and provide a practical exercise for using it to determine the mechanical properties of different materials. 2. To understand the principle of tensile test. 3. To understand the Stress-Strain curve and learn how to use it in determining various mechanical properties of different materials (Aluminum, Copper and Stainless Steel): modulus of elasticity, yield strength, ultimate tensile strength and elongation (ductility). Background A tensile test, also known as tension test, is probably the most fundamental type ofmechanical test you can perform on material to recognize its strength and its mechanical behavior. Tension test, in which a strip or cylinder of the material, having length L and cross-sectional area A, is anchored at one end and subjected to an axial load P a load acting along the specimen s long axis at the other. As the load is increased gradually, the axial deflection δ of the loaded end will increase also. Eventually the test specimen breaks or does something else catastrophic, often fracturing suddenly into two or more pieces. The strain resulting from the stress applied is proportional to the stress and is directly related to it with a proportionality constant called the Elastic Modulus/ Young s Modulus. This constant is material dependent and only applies in what is called the "elastic region" of a material s behavior through the following equation: = Where ( ) is the Stress in Pascal, ( ) is the Strain and (E) is the Elastic Modulus or Young s Modulus

A typical stress-strain curve is shown in the figure below: Stress ( Strain ( Stress versus Strain Curve Note that stress - strain proportionality only applies in the elastic region (up to the yield stress point), also note that this curve assumes a constant cross-sectional area and does not take into consideration the Poisson s Ratio. The Poisson s Ratio(ν) is the ratio of transverse contraction strain to longitudinal extension strain in the direction of stretching force and is approximated to be 1/3 for isotropic metals and ½ for anisotropic polymers. Definitions Gauge Length (L) - length of the test specimen on which elongation is measured at any moment during the test [m] Original Gauge Length (L 0 ) - gauge length before application of load [m] Final Gauge Length (L u ) - gauge length after rupture of the test specimen [m] Elongation - increase in the original gauge length at the end of the test Stress (σ)- load at any moment during the test divided by the original cross-sectional area of the test specimen [Pa/ (N/m 2 )] Strain- It is the ratio of change in length to the original length ( = ) Elastic Modulus-a measure of the stiffness of the material, but it only applies in the linear region of the stress strain curve ( = / ), [Pa]

Yield Stress (σ y )-when the material exhibits a yield phenomenon, a point is reached during the test at which plastic deformation occurs without any increase in the load [Pa/(N/m 2 )] Ultimate Tensile Stress (σ u )-the maximum load the specimen sustains during the test[pa/ (N/m 2 )] Equipments 1. PC Computer 2. Biomaterial Testing Machine (800LE Series Hardware) Universal Testing Machine Overview Biomaterial testing machine is used to generate force and measure fatigue, fracture, tensile and compression test results on mechanical test samples. They are capable of producing static and cyclic loads in tension or compression and operate to speeds of depending on the system performance System Components Test system typically consistsof: 1. Frame 2. Actuator 3. Power module electronics 4. Controller with interconnect cables Adjustable Crosshead Each system includes a power pack with the following operator indicators and switches: System ON/OFF System Enable LED Emergency Stop Grips Specimen Safety Warnings 1. Excessive side load on the output rod of the actuator will dramatically reduce the life of the Actuator and should be avoided completely. Side load can be caused from misalignment or Loading of the specimen which is not in line with the axis of motion.

1. The equipment may be so heavy. Don't move it. 2. Never lift the equipment by the actuator rod. 3. Never use the system if it appears damaged in any way. 4. This equipment may contain sensitive position sensors and should be handled with care. General Safety Concerns Mechanical testing is an inherently dangerous activity since the product being tested may behave or fail in a way that is not expected. The nature of testing is to determine what happens when various conditions are present that have never been tested before In addition, servo-controlled systems, by their nature have many variables that must be factored in real time by the operator of the machine. In many cases, the person wanting to operate the machine may be lacking in training or experience and so may choose to place a sample in a dangerous mode. This is the nature of performing research on new products and materials. Since all materials and products fail in different modes, the user is responsible to determine the risk and to solve the problem of minimizing it. For example, if the material tested is brittle and fails in a catastrophic and dangerous manner, a safety enclosure is recommended to contain the product being tested. Procedure 1. Prepare Test Specimen: During the lab different materials with different properties will be used. For each test specimen, determine the following parameters as the table below: Parameter Gauge length (L 0 ) (mm) Width (w) (mm) Thickness (t) (mm) Type of Test Specimen ------------------------- Type of Test Specimen ----------------------- 2. Check that all cables are properly and securely connected. Switch on all power Switches in the following sequence: a) Main power switch b) Control Power c) Computer.

A Five minute warm up period is necessary before starting your test. 3. Start the Software: a. Double click on the TestBuilderV3 icon. The software will connect automatically. b. Click on the "proceed " button c. The TestBuilderV3 main screen will appear as shown below.

d. Click on the "Function Generator" The function generator application is intended for simple movement of the actuator. e. Use position mode to jog the load cell and fixtures f. Select the Jog button down the right hand side of the software screen. The Jog panel allows you to manual move the actuator into place to load your specimen into the gripsas shown below:

g. Tare readout: In most cases before you insert your sample into the fixtures on the test machine you will want to tare or zero the weight of the fixture, because this is not load seen by the sample. To tare or zero the weight of the fixture. Click on the setup on the top menu bar as shown below and click on offset Readout. h. Start the tensile test (Tension) by carrying out the following procedure: Click the DAQ button enter the DAQ rate use 50 for static test then save your folder Start you test by switch on the function generator Note: You could always stop a test by pressing the Emergency Stop Button, which isa large, round, red button located on the front of the load frame. Press this button tostop crosshead travel immediately when a condition develops that could affect thesafety of persons operating the system, or could damage the specimen or the testfixtures. Pressing the Emergency Stop Button stops the system instantly and disablesthe frame s drive motor. Once you ve completed your test Click on the Report icon to generate a report and export to excel. Once tensile testing is complete, remove the test specimen from fixtures. Repeat the procedure for the second specimen.