Vinmetrica Deluxe Lab Accessory Kit User Manual

Similar documents
Volumetric Measurement Techniques. Technique #1 Use of a Burette. Technique #2 Use of a Pipette. Technique #3 Use of a Volumetric Flask

Vinmetrica SC-300 Pro Kit User Manual

Vinmetrica SC-200 User Manual

Owner's Manual NSL100B BUILDERS LEVEL NSL500B TRANSIT LEVEL

CAUTION: BEFORE YOU BEGIN, ALWAYS MAKE SURE THE WEAPON IS UNLOADED AND SAFE TO HANDLE.

Vinmetrica Alcohol-by-Volume User Manual

Must Read Before Installation TadPoleTM Safety and Warnings

6 Acid Base Titration

CHEM Practice to be done before the lab. Experiment 9 Introduction to Volumetric Techniques II. Objectives

NaOH (aq) + HCl (aq) NaCl (aq) + H 2 O (l)

POGIL LAB EXERCISE 15 HOW DO YOU STANDARDIZE AN ACID AND BASE?

Chemical Reactions: The Copper Cycle

Working in the Chemistry Laboratory

experiment7 Explaining the difference between analyte and standard solutions. Know the definition of equivalence point.

# 12 ph-titration of Strong Acids with Strong Bases

FIELD GUIDE FOR HORUS SCOPES

Acid-Base Titration. Evaluation copy

#09 Investigating the Relationship between the Mass of a Liquid and its Volume Ken Lyle, St. John s School, Houston, TX

TRATION: ANALYSIS OF VINE

MassWWP Standard Operating Procedure L-6 ph and Alkalinity Rev.0 Page 1 of 12

Standardizing a Solution of Sodium Hydroxide. Evaluation copy

Experiment: Titration

Our Drop Counter sensor now features housing for two electrode sensors, an anti-twist mechanism, an indicator LED and two cable guides.

Acid-Base Titration. Sample

Titration with an Acid and a Base

Using Conductivity to Find an Equivalence Point

INSTRUCTIONS FOR ATTACHING THE NORDIC PLOW TO THE ACTION TRACKCHAIR

Experiment 20-Acid-Base Titration: Standardization of KOH and Determination of the Molarity and/or Percent Composition of an Acid Solution

Microscale Acid-Base Titration

Density of an Unknown

Conductometric Titration & Gravimetric Determination of a Precipitate

Experiment C-10 Titration of a Strong Acid and a Strong Base

Total Carboxylic Acid Group Content Applicable Products: Carbopol * Polymers and Pemulen * Polymeric Emulsifiers

Experiment 7: ACID-BASE TITRATION: STANDARDIZATION OF A SOLUTION

User s Guide. Waterproof Palm ph Meter Model PH220. Introduction

Microscale Acid-Base Titration

To measure ph s in a variety of solutions and mixtures and to account for the results obtained.

Experimental Procedure

Chemical Reactions: Titrations

IF YOU NEED ANY FURTHER HELP WITH YOUR GALILEO TELESCOPE PLEASE CALL MON-FRI 9AM - 5PM E.S.COM

Operating Instructions Validation Tool Kit, KT2 For use with USP Apparatus #1 & #2

u s e r m a n u a l w w w. v e l a. E U

(b) Write the chemical equation for the dissolution of NaOH in water.

GETTING THE END POINT TO APPROXIMATE. Two hours

Solvothermal Technique Guidelines

CHEM 334 Quantitative Analysis Laboratory

Experimental Procedure. Lab 406

POLYPHOSPHORIC ACID ASSAY

Owner's Manual. for AUTOMATIC LEVEL. NBL Series. FOR CUSTOMER SERVICE, PARTS & REPAIR, CALL Toll Free:

Apply the ideal gas law (PV = nrt) to experimentally determine the number of moles of carbon dioxide gas generated

Ascorbic Acid Titration of Vitamin C Tablets

Learn to do quantitative titration reactions. Observe the mole ratios of several simple chemical reactions.

ACID-BASE TITRATION (MICROSCALE)

H 3 O + (aq) + P 2- (aq)

Experiment#1 Beer s Law: Absorption Spectroscopy of Cobalt(II)

SK Series BOX PLOW INSTALLATION & OWNER S MANUAL TABLE OF CONTENTS

CASSINI CQR-120 OPERATING INSTRUCTIONS

N) manual. Biomaster Operating manual

Acid-Base Titration. M M V a

EXPERIMENT. Titration for Acetic Acid in Vinegar

INTRODUCTION TO MICROSCALE ORGANIC CHEMISTRY

Titration of Acetic Acid in Vinegar Minneapolis Community and Technical College v.9.17

symphony Reference Electrodes

HEAVY DUTY SWING-OUT VALVE

WHEN BRIGHTNESS COUNTS

INSTRUCTION MANUAL. Laser Diode Sarcomere Length. Aurora Scientific Inc. 360 Industrial Parkway South, Unit 4 Aurora, Ontario, Canada L4G 3V7

Final Concentration 0 excess 0.1 M 0.1 M

Experiment 20: Analysis of Vinegar. Materials:

POTENTIOMETRIC TITRATIONS & SOLUBILITY EQUILIBRIA. Background

To use calorimetry results to calculate the specific heat of an unknown metal. To determine heat of reaction ( H) from calorimetry measurements.

product manual H-3220A Benkelman Beam

Gluten (Gliadin) Lateral Flow IIR

Potentiometric Determination of the pka and the Equivalent Weight of a Weak Acid

WS-7047TWC Wireless 433 MHz Weather Station With Rainfall and Temperature. Instruction Manual

Periodicity of Properties of Oxides

HEAVY DUTY SWING-OUT VALVE

SKELESCOPE REFLECTOR TELESCOPE WITH TABLE TOP TRIPOD SK-100 INSTRUCTION MANUAL

Australian National Titration Competition. Basics of Titration

Experiment #10: Analysis of Antacids

Acid Base Titration Experiment ACID - BASE TITRATION LAB

CHEMISTRY 130 General Chemistry I. Thermochemistry

Temperature Profile for 36 Marker Spheres on 3M 788 ACCR Conductor 3M Company

Measuring Ammonia in Water and Wastewater using the Thermo Scientific Orion Dual Star ph/ise Meter

PRETREATMENT TECHNICAL DATA SHEET A CHROME-FREE FINAL RINSE PRODUCT DESCRIPTION

user manual blotting Hoefer PR648 Slot blot manifold um PR648-IM/Rev.F0/08-12

POWER PUSHER Snowplow

#13 ph-titration of Weak Acids with Strong Bases

PHS-25CW/3BW Benchtop ph Meter Instruction Manual

Altazimuth Mount. Altazimuth Mount

Conductimetric Titration and Gravimetric Determination of a Precipitate

Experiment C-15 Distillation - part 1

Titration of an Unknown Acid

Instruction Manual. Kite-22 Camera Crane Starter Package (KITE-22-STARTER) Exclusive of Weights

6. Common Laboratory Techniques

ICE MANTLE MAKER MODEL 452 User Maintenance Manual/Handbook

COMMODORE BRASS TELESCOPE ZHUMELL COMMODORE BRASS TELESCOPE

Vinmetrica SC-300 Kit User Manual

PLOW MOUNT KIT FOR POLARIS RANGER P/N ASSEMBLY / OWNERS MANUAL

Conversion Kit for: 7620 and 7820 Swing-Out Valves ft-lbs ft-lbs 8835/ ft-lbs

INSTRUCTION MANUAL. Type: ORP500 C, ORP500 CD, ORP222 CD, ORP223 CD EN Introduction Helpful Operating Tips. 2

Transcription:

Vinmetrica Deluxe Lab Accessory Kit User Manual The Vinmetrica Deluxe Lab Accessory Kit is a compilation of the best laboratory equipment available. It is the perfect companion for our SC-100*, SC-100A*, SC-200* and SC-300* Analyzer Kits and allows its users to measure wine samples faster, with better resolution and higher precision. Materials Provided in the Kit: 1. 10mL or 25mL glass burette with Teflon stopcock (included: ~2 grams burette detergent) 2. Lab Support Stand 3. Double Burette Clamp 4. Magnetic Stirrer (batteries included) 5. Electrode Holder 6. Rinse Bottle Things you will need: 1. Distilled water, which can be found most grocery stores. 2. (Optional) Titration Beaker. Available from Vinmetrica (Part Number: SC-100-16). 3. (Optional) Burette Detergent. Available from Vinmetrica (Part Number: SC-300-12). Benefits of using the Deluxe Lab Accessory Kit: Precision and accuracy are necessary for creating high quality wines. The glass burette allows the highest possible resolution and precision when measuring out titrant levels. The burette has gradations for every 0.05mL with the 10mL burette and 0.10mL with the 25mL burette, which ever you have. The Teflon stopcock ensures easy maintenance and smooth titrations again and again. The capacity of the burette (either 10mL or 25mL) allows you to do more titrations without having to refill the burette each time. If you have a number of wine samples to handle at once, this can be a huge time saver! All you have to do it make sure to write down your starting and final level for each titration and then you can proceed to the next one. * US and Intl Patent Pending Deluxe Lab Accessory Kit Manual 1 Version 1.1

The included burette detergent ensures your burette will remain clean and accurate after each use.the Lab Support Stand and the Double Burette Clamp make adjusting the height of the burette easy. Using simple thumb screws, these two pieces easily fit together with the intent of keeping your burette secure while titrating. Also included is the magnetic stirrer and included stir bar to give you a hands free way to keep your wine sample stirring while you can focus on performing an accurate titration. The magnetic stirrer comes with a 50mL cylinder but is best used with the titration beaker provided with any one of the Vinmetrica analyzers. When using the magnetic stirrer, it is important to keep your electrode away from the spinning stir bar. The Electrode Holder keeps your electrode steady when you are performing a titration. It easily attaches to the Lab Support Stand using a simple thumb screw and can be adjusted up or down depending on your need. This ensures the safety of the electrode. The Electrode Holder can hold up to two electrodes simultaneously and also has a convenient slot for guiding the tip of the burette into. The burette will not slide directly into the slot at the end of the electrode holder; it is simply a guide. Deluxe Lab Accessory Kit Manual 2 Version 1.1

Assembling the Deluxe Lab Accessory Equipment: 1. Remove the items from their packaging: the Lab Support Stand, the Vinmetrica Electrode Holder, the Double Burette Clamp, the Glass Burette and the Magnetic Stirrer. Carefully pull out the glass burette from its cardboard cylindrical container. Use caution not to exert too much force on the burette as it is fragile and can break. 2. Open the Magnetic Stirrer from its packaging and insert the double AA batteries included. For ph measurements, we recommend you do not use the cylindrical container provided with the magnetic stirrer but use the 100mL titration beaker included with the SC-100A and SC-300. 3. Assemble the Lab Support Stand by attaching the long metal rod and screwing it into the large metal base. We have found that adding a drop of super glue to the threads of the metal rod can prevent loosening of the assembly. Then place the magnetic stirrer below the lab support (Figure 1). 4. To attach the Electrode Holder, loosen the thumb screw on the Holder and slide it onto the Lab Support Stand rod (Figure 2). The small lip in each large hole should be at the bottom of the hole and the thumb screw should be on the left hand side. Then tighten the thumb screw to adjust it to an appropriate height (Figure 3). 5. Attach the Double Burette clamp to the Lab Support Stand using its thumb screw to adjust for height, as shown in Figure 8 below. Usually with the burette attached to the Double Burette Clamp, you may need to adjust both of them to the right height to read it properly. Figure 1. The Magnetic stirrer and beaker with the ph electrode inserted into the Electrode Holder to 7. the Carefully wine sample. open th Figure 2. The Vinmetrica Electrode Holder slides onto the Lab Support Stand. Figure 3. The thumb screw makes adjusting The Electrode Holder's height easy. Figure 4. The Double Burette Clamp slides easily onto the Lab Support Stand. Deluxe Lab Accessory Kit Manual 3 Version 1.1

6. Carefully open the Double Burette Clamp's spring arms with your thumb and forefinger and place the burette in between the four indentations in the double burette clamp's spring arm's plastic knobs. Slowly release the clamp spring to secure the burette between these four spring arm plastic knobs. You can adjust the burette at any time by raising and lowering it within the spring arm clamps of the Double Burette Clamp. When making these adjustments, hold onto the burette and do not apply too much force to it as the burette is delicate. Use the end of the Electrode Holder as a guide for the tip of the burette (Figure 7). DO NOT try and force the burette into the cutout at the end of the electrode holder. This may cause your burette to snap and break. 7. Finally, insert the electrode that you wish to use into one of the open side slots (as seen in Figure 1). Once the rubber neck of the electrode is sitting on top of the electrode holder, you can press down on the rubber neck gently so the electrode is further stabilized into the slot. You are now ready to titrate! Note: The magnetic stir bar that is placed within the 100 ml titration beaker can potentially damage the SO 2 and ph electrodes. When adjusting the height of the electrodes, make sure that the stir bar in the beaker is below the bottom of the electrode. You do not want the spinning magnetic stir bar to strike the SO 2 or ph electrode. When titrating for SO 2 or TA, you can add a few milliliters of distilled water to raise the liquid level in the titration beaker by a half inch or so. Figure 5. The glass burette should be placed between two sets of spring arm knobs on the Double Burette Clamp. Figure 6. The burette sits firmly between the notches of the four spring arm knobs of the Double Burette Clamp. Figure 7. The glass burette tip can be placed just outside the Electrode Holder's front slot for accurate titrations. Figure 8. The Pro Kit Assembly is complete. Go take some measurements! Deluxe Lab Accessory Kit Manual 4 Version 1.1

Burette Maintenance Keep the burette clean and wash with deionized (distilled) water when you are finished using the burette. This is especially important for TA titrations because the TA Titrant is caustic and can etch the burette. Every so often, you will want to clean your burette with a cleaning solution to maintain accuracy of the burette. The included ~2 grams of Burette Detergent is specially formulated to clean glassware. The dry detergent ships in an Eppendorf tube that has markings with approximate half gram increments. Upon first receiving the detergent, mix approximately half a gram (about an 1/8th of a teaspoon) with about 50 milliliters (ml) of distilled water into a small bottle. We recommend capping the bottle and shaking well for a minute or until the detergent is dissolved. Bubbles may form but the detergent will still be effective. The detergent solution should be made fresh every time you clean the burette, as it loses its potency quickly if stored as a liquid. After you have run distilled water through your burette, close the stopcock, and fill with the Burette Detergent solution. You can open and close the stopcock over a waste bucket or sink to allow the solution to pass into the tip of the stopcock. We recommend letting this detergent solution sit in the burette for one hour. Dispense the detergent solution then rinse the burette with distilled water twice more. During this time we recommend opening and closing the stopcock to make sure the stopcock is turning easily. If it is not, remove the stopcock and clean it thoroughly. Once drained, allow to hang dry by hanging the burette upside down with the stopcock in the open position. Once the burette is dry, cover the top opening with a piece of tape. This will prevent dust from getting in that can cause aberrations when reading the burette. Remove the tape when you're ready to titrate. Burette Reading ALWAYS use eye protection and preferably gloves (latex or nitrile) when using glassware and chemical reagents. To get the most accurate results when titrating, there are a few things to keep in mind. We recommend reading from the bottom of the meniscus (Figure 10 on the following page). First, use a thick sheet of white paper, note card or the back of a business card and draw a black band down the center of the paper about an inch and a half thick (Figure 9). When taking a measurement, hold the paper about an inch behind the burette and the black band about a half an inch below the meniscus (Figure 11). This provides a clear view of the bottom of the meniscus which helps make a precise, consistent measurement. Second, when filling the burette make sure the titrant (in most cases this will be either the SO 2 Titrant or the TA Titrant) has completely filled the bottom of the burette including within the tip. Sometimes bubbles can be trapped in the tip of the burette but can usually be dislodged by opening and closing the stopcock while the burette is hovering over a waste container. We also recommend washing a couple of milliliters of the titrant you are using through the burette to remove any Deluxe Lab Accessory Kit Manual 5 Version 1.1

excess water or contaminants that may remain from a previous titration. Finally, make sure there are not any large bubbles in the burette after filling. If there are, cover the top of the burette with some saran wrap (or parafilm if you have it) and make sure the stopcock is in the closed position. Then take the burette out of its clamp and hold the saran wrapped end tightly. Rotate and invert the burette to allow the bubbles to move out of the column of titrant. Once the bubbles have been displaced, you are ready to titrate. NOTE: The gradations on your burette may be different than shown in the figures below. These photos are of the 10mL burette; the 25 ml burette will have fewer gradations. Please take a look at your burette and determine the values for the gradations (lines). Figure 9. On a thick white sheet of paper or a business card, use a black marker to draw a band approximately an inch and a half thick. This card will assist you in reading the burette accurately. Figure 10. The Meniscus of the water column. This curve is formed because of interactions of water with the glass burette. We recommend measuring the titrant volume from the bottom of the meniscus. In the picture the value is about 3.27 ml. Figure 11. Reading the Meniscus of the water column is easier and more precise if you use the paper with the black band held up an inch behind the burette and its black band 1/2 an inch below the meniscus. In this picture the value from Figure 17 is further resolved to 3.26 ml. Before beginning the titration, record the starting titration volume, using the thick white paper with the black band, and then begin titrating, slowly. With enough practice, you will eventually be able to read the burette without the black banded paper. Record the final titration volume using the same technique. You can also checkout these websites for more burette info: http://www.titrations.info/pipette-burette or http://www.csudh.edu/oliver/demos/buretuse/buretuse.htm Deluxe Lab Accessory Kit Manual 6 Version 1.1

WARRANTIES AND LIABILITIES 1. The materials provided in the kit, as described on pages 1 and 2 above, ( Materials ) are warranted as follows: The SC-300 instrument, electrodes and non-reagent accessories are warranted against defects in workmanship for 12 months from date of purchase. The reagents are warranted to perform as described herein up until any stated expiration date or 6 months after purchase, whichever is later. THE WARRANTIES IN THESE TERMS AND CONDITIONS ARE IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION ANY WARRANTIES OF MERCHANTABILITY, NONINFRINGEMENT, OR FITNESS FOR A PARTICULAR PURPOSE, SAID WARRANTIES BEING EXPRESSLY DISCLAIMED. 2. Buyer agrees that its sole and exclusive remedy against Vinmetrica shall be limited to the repair and replacement of Materials or parts of Materials, provided Vinmetrica is promptly notified in writing, prior to the expiration of the warranty period specified above, of any defect. Vinmetrica s liability for any damages due Buyer shall be limited to the purchase price of the Materials. 3. VINMETRICA'S MAXIMUM LIABILITY FOR ALL DIRECT DAMAGES, INCLUDING WITHOUT LIMITATION CONTRACT DAMAGES AND DAMAGES FOR INJURIES TO PERSONS OR PROPERTY, WHETHER ARISING FROM VINMETRICA S BREACH OF THESE TERMS AND CONDITIONS, BREACH OF WARRANTY, NEGLIGENCE, STRICT LIABILITY, OR OTHER TORT WITH RESPECT TO THE MATERIALS, OR ANY SERVICES IN CONNECTION WITH THE MATERIALS, IS LIMITED TO AN AMOUNT NOT TO EXCEED THE PRICE OF THE MATERIALS. IN NO EVENT SHALL VINMETRICA BE LIABLE TO BUYER FOR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES, INCLUDING WITHOUT LIMITATION LOST REVENUES AND PROFITS. HAZARDS AND TOXICITY All Materials offered by Vinmetrica are intended for use by individuals who are familiar with laboratory procedures and their potential hazards. The Materials contain chemicals which may be harmful if misused. Due care should be exercised with all Materials to prevent direct human contact. Glassware can break and chemicals can splash during experiments; Always use safety glasses. We strongly recommend using nitrile or latex gloves and wearing long pants, long sleeves and closed toed shoes. Keep out of reach of children. 6084 Corte Del Cedro Suite 105, Carlsbad CA 92011 www.vinmetrica.com (760) 494-0597 info@vinmetrica.com Copyright 2010-16. Sportsman Consulting, LLC DBA Vinmetrica. All rights reserved. Deluxe Lab Accessory Kit Manual 7 Version 1.1