Accurate analysis of neptunium 237 in a uranium matrix, using ICP-QQQ with MS/MS

Similar documents
Determination of trace elements in ultrapure semiconductor grade sulfuric acid using the Agilent 8900 ICP-QQQ in MS/MS mode

Determination of challenging elements in ultrapure semiconductor grade sulfuric acid by Triple Quadrupole ICP-MS

Lead isotope analysis: Removal of 204 Hg isobaric interference from 204 Pb using ICP-QQQ in MS/MS mode

The ultratrace determination of iodine 129 in aqueous samples using the 7700x ICP-MS with oxygen reaction mode

Trace elemental analysis of distilled alcoholic beverages using the Agilent 7700x ICP-MS with octopole collision/ reaction cell

Application note. Trace level analysis of sulfur, phosphorus, silicon and chlorine in NMP using the Agilent 8800 Triple Quadrupole ICP-MS

Ultra trace measurement of potassium and other elements in ultrapure water using the Agilent 8800 ICP-QQQ in cool plasma reaction cell mode

Accurate Analysis of Trace Mercury in Cosmetics using the Agilent 8900 ICP-QQQ

Enhancing the productivity of food sample analysis with the Agilent 7700x ICP-MS

Agilent s New 8800 ICP-QQQ. Transforming ICP-MS Technology

Direct Analysis of Trace Metal Impurities in High Purity Nitric Acid Using ICP-QQQ

Direct Measurement of Metallic Impurities in 20% Ammonium Hydroxide by 7700s/7900 ICP-MS

Multi-Element Analysis of Petroleum Crude Oils using an Agilent 7900 ICP-MS

Rapid Analysis of High-Matrix Environmental Samples Using the Agilent 7500cx ICP-MS. Application. Author. Abstract. Introduction.

The Agilent 7700x ICP-MS Advantage for Drinking Water Analysis

Multi-Element Analysis of Cannabis using the Agilent 7800 ICP-MS

Agilent 8900 Triple Quadrupole ICP-MS

Analysis of Trace Metal Impurities in High Purity Hydrochloric Acid Using ICP-QQQ

Elemental analysis of river sediment using the Agilent 4200 MP-AES

Comparing Collision/Reaction Cell Modes for the Measurement of Interfered Analytes in Complex Matrices using the Agilent 7700 Series ICP-MS

High Throughput Water Analysis using Agilent 7900 ICP-MS coupled with ESI prepfast

Agilent s Solutions for Nanoparticles Analysis ICP-MS, ICP-MS/MS, software. Alain Desprez Agilent Technologies

High Sensitivity HPLC Analysis of Perchlorate in Tap Water Using an Agilent 6460 Triple Quadrupole LC/MS System

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Determination of Chromium in Gelatin Capsules using an Agilent 7700x ICP-MS

Single particle analysis using the Agilent 7700x ICP-MS

Simple, reliable analysis of high matrix samples according to US EPA Method 6020A using the Agilent 7700x/7800 ICP-MS

High-Speed Environmental Analysis Using the Agilent 7500cx with Integrated Sample Introduction System Discrete Sampling (ISIS DS)

Application Note. Abstract. Authors. Environmental

Determination of major, minor and trace elements in rice fl our using the 4200 Microwave Plasma- Atomic Emission Spectrometer (MP-AES) Authors

Application note. Accurate determination of sulfur in biodiesel using Isotope Dilution-Triple Quadrupole ICP-MS (ID-ICP-QQQ) Petrochemical

Trace Analyses in Metal Matrices Using the ELAN DRC II

Ultra-fast determination of base metals in geochemical samples using the 5100 SVDV ICP-OES

Techniques for the Analysis of Organic Chemicals by Inductively Coupled Plasma Mass Spectrometry (ICP-MS)

Analysis of Arsenic, Selenium and Antimony in Seawater by Continuous-Flow Hydride ICP-MS with ISIS

Applications of ICP-MS for Trace Elemental Analysis in the Hydrocarbon Processing Industry

Semiquantitative Screening of Pharmaceutical Antiviral Drugs using the Agilent 7500ce ICP-MS in Helium Collision Mode

Analysis of domestic sludge using the Agilent 4200 MP-AES

Agilent ICP-MS. Fundamentals of ICP-MS Analysis and Its Applications for Low Level Elemental Determination in Cannabis

Direct Analysis of Photoresist Using Inductively Coupled Plasma Mass Spectrometry (ICP-MS) Application

Thermo Scientific icap TQ ICP-MS: Typical limits of detection

Determination of Hormones in Drinking Water by LC/MS/MS Using an Agilent InfinityLab Poroshell HPH Column (EPA 539)

Determination of Impurities in Silica Wafers with the NexION 300S/350S ICP-MS

Application. Determination of Trace Metal Impurities in Semiconductor-Grade Hydrofluoric Acid. Authors. Introduction. Abstract.

Implementing EPA Method 6020 with the Agilent ICP-MS Portfolio

Hands on mass spectrometry: ICP-MS analysis of enriched 82 Se samples for the LUCIFER experiment

Identification and Quantitation of PCB Aroclor Mixtures in a Single Run Using the Agilent 7000B Triple Quadrupole GC/MS

Application note. Determination of exchangeable cations in soil extracts using the Agilent 4100 Microwave Plasma-Atomic Emission Spectrometer

Unmatched Removal of Spectral Interferences in ICP-MS Using the Agilent Octopole Reaction System with Helium Collision Mode Application

Fundamentals of the ICP-MS Technique and How to Resolve Issues for Pharmaceutical Materials (In 20 Minutes) Tim Shelbourn, Eli Lilly and Company

Quantitative analysis of high purity metals using laser ablation coupled to an Agilent 7900 ICP-MS

Accurate Determination of TiO 2 Nanoparticles in Complex Matrices using the Agilent 8900 ICP-QQQ

Agilent Technologies at TIAFT 2013

Accurate Mass Analysis of Hydraulic Fracturing Waters: Identification of Polyethylene Glycol Surfactants by LC/Q-TOF-MS

Determination of Pb, Cd, Cr and Ni in Grains Based on Four Chinese National Methods via Zeeman GFAAS

Analysis of noble metals at low levels in geological reference materials and ores

Determination of Phosphorus and Sulfur with Dynamic Reaction Cell ICP-MS

Analysis of Biomarkers in Crude Oil Using the Agilent 7200 GC/Q-TOF

Performance of the Agilent 7900 ICP-MS with UHMI for high salt matrix analysis

Real World Analysis of Trace Metals in Drinking Water Using the Agilent 7500ce ICP-MS with Enhanced ORS Technology. Application. Authors.

Thermo Scientific icap RQ ICP-MS: Typical limits of detection

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

Fast Analysis of Water Samples Comparing Axially-and Radially- Viewed CCD Simultaneous ICP-OES

High-Throughput Semiquantitative Screening of Ambient Air Samples by ORS-ICP-MS and Integrated Sample Introduction System (ISIS) Application

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

ICP-OES Application Note Number 35

Determination of Chlorinated Acid Herbicides in Soil by LC/MS/MS Application Note

China Soil Pollution Survey: Elemental Analysis of Soil and Sediment Digests by ICP-MS

Low Level Detection of Priority Inorganic Pollutants in Water. Anthony Neumann, MSc Darren Crichton, BSc

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

Quantitative Analysis of Water-Soluble B-Vitamins in Cereal Using Rapid Resolution LC/MS/MS. Application. Authors. Abstract.

LC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode

Advantages of ICP-QQQ for nuclear waste characterisation

Defining quality standards for the analysis of solid samples

IMPROVING DATA QUALITY WITH ADVANCED INSTRUMENTATION UTILIZING MULTIPLE INTERFERENCE REDUCTION TECHNOLOGIES

Direct Measurement of Trace Metals in Edible Oils by 7500cx ICP-MS with Octopole Reaction System

Analysis of high matrix samples using argon gas dilution with the Thermo Scientific icap RQ ICP-MS

Fergus Keenan Shona McSheehy Julian Wills

Inductively Coupled Plasma Mass Spectrometry (ICP-MS) Debjani Banerjee Department of Chemical Engineering IIT Kanpur

On-line isotope dilution analysis with the 7700 Series ICP-MS: Analysis of trace elements in high matrix samples

Simple and Reliable Soil Analysis using the Agilent 7800 ICP-MS with ISIS 3

Determination of ultratrace elements in photoresist solvents using the Thermo Scientific icap TQs ICP-MS

Accurate measurement of elemental impurities in metals and metal alloys using the Thermo Scientific icap TQ ICP-MS

Using UHPLC-Triple Quadrupole MS/MS to Detect the Presence of Bark Extract and Yohimbine Adulteration in Dietary Supplements and Botanicals

Determination of iopromide in environmental waters by ion chromatography-icp-ms

Analysis of Ethanol and Isotopomers by 240 Quadrupole Ion Trap GC/MS

MS n Analysis With Fast Polarity Switching in the Agilent 1100 Series LC/MSD Trap SL. Application Note. Christine Miller Agilent Technologies

Use of ICP-MS in analysing radioisotopes. Per Roos Risø National Laboratory for Sustainable Energy, Technicial University of Denmark

Determination of Off-Odor Compounds in Drinking Water Using an SPME Device with Gas Chromatography and Mass Spectrometry

Automated Determination of PPQ Levels of Thorium in High Purity Copper

Explosive Screening by Vapour Detection: Operational Aspects

Hydride Generation for the Determination of As, Sb, Se and Bi Using the Teledyne Leeman Lab s Prodigy 7 ICP-OES

Sensitive Detection of 2-MIB and Geosmin in Drinking Water

The Investigation of Fertilizer Analyses Using Microwave Digestion and the Agilent 720-ES

The Characterization of Nanoparticle Element Oxide Slurries Used in Chemical-Mechanical Planarization by Single Particle ICP-MS

Rapid, simple, interference-free analysis of environmental samples using the XSERIES 2 ICP-MS with 3 rd generation CCT ED

Identification and Quantitation of Pesticides in Chamomile and Ginger Extracts Using an Agilent 6460 Triple Quadrupole LC/MS system with Triggered MRM

Agilent 6460 Triple Quadrupole LC/MS System with an Agilent 1290 Infinity LC For Multi-Plant Growth Regulator Analysis in Grapes

Accurate Mass Measurement for Intact Proteins using ESI-oa-TOF. Application Note. Donghui Yi and Christine Miller Agilent Technologies

Ultratrace analysis of radionuclides by AMS

Transcription:

Accurate analysis of neptunium in a uranium matrix, using ICP-QQQ with MS/MS Application note Nuclear, environmental Authors Garry Duckworth, Springfields Fuels Ltd, K, Glenn Woods, Agilent Technologies, K, Introduction The radioactive actinide element neptunium (Np) is formed by neutron bombardment of uranium (), with more than 50,000 kg of Np produced annually as a by-product of nuclear-power generation. Smaller quantities of Np can be found as a decay product of americium-241 ( 241 Am) used in ionizing smoke detectors, with trace quantities being produced from nuclear bomb testing, and naturally (from natural neutron capture) in ores.

The predominant isotope Np is produced as follows: Np sits at the top of the neptunium decay series which in turn produces a series of other radioactive elements with medium to very short half-lives, eventually forming Bi and Tl (Figure 1). Np is extremely mobile in the environment, as it readily forms aqueous solutions (more so than any other actinide), attaches to particles and colloids, and does not readily become trapped in humic substrates such as soil. Np also has a high affinity for calcium-rich materials including certain clays and concrete, so care is needed with its storage. Although Np is not readily absorbed in the human gut, once in the body, it will pre-concentrate in the bones. The relatively long half-life of Np (~2.14 million years) means that it is persistent in the environment, so it requires suitable containment, and needs to be monitored at low levels. Abundance sensitivity of ICP-QQQ with MS/MS Samples that contain Np usually contain at far higher concentrations. The determination of ultra-trace Np in environmental samples and nuclear materials (fuel or waste) is difficult by ICP-MS because of the overlap due to peak tailing from the large 238 peak. Conventional quadrupole ICP-MS instruments (ICP- QMS) operate at unit mass resolution to separate adjacent masses, meaning a nominal resolution (expressed as M/ΔM) of at m/z. However, peak separation also depends on the abundance sensitivity (AS) of the spectrometer. AS is a measure of the peak tailing, calculated from the contribution that an intense peak makes to its neighbouring masses. Figure 1. Np- decay series. Adapted from The NBASE Evaluation of Nuclear and Decay Properties. Nuclear Physics A 729: 3 128. DOI: 10.1016/j.nuclphysa.2003.11.001 Quadrupole ICP-MS instruments can achieve AS of up to 1 x 10-7 (a peak of 1 x 10 7 cps contributes 1 cps to the adjacent masses), so a peak with an intensity much higher than 10 7 cps will make a significant contribution to the peaks either side. High Resolution-Sector Field (HR-SF)-ICP-MS has better resolution than ICP-QMS (M/ΔM of up to 10,000), but poorer AS. So adjacent peaks may appear to be separated on the mass scale, but the peak tail of an intense peak may still contribute to the masses above and below. The Agilent 8800 or 8900 Triple Quadrupole ICP-MS (ICP-QQQ) use a unique configuration with two quadrupole mass analyzers (Q1 and Q2) either side of the collision reaction cell. When both quadrupoles are operated as unit mass filters (MS/MS mode), this configuration delivers unmatched peak separation because the abundance sensitivity performance is the product of two mass separations Q1 AS x Q2 AS giving an overall AS of <<10-10. 2

ICP-QQQ is therefore able to successfully separate Np from the 238 overlap, even when the is present at many orders of magnitude higher concentration. This is demonstrated in Figure 2, which shows the spectra of 100 ppt Np in a 10 ppm matrix measured in Single Quad (SQ) mode (top) and MS/MS mode below. The ICP-QQQ spectrum shows the superior peak separation provided by MS/MS mode, and the clear elimination of the contribution on mass from the adjacent 238 peak. 234 235 238 Np cannot be measured due to overlap from the 238 peak Table 1. ICP-QQQ operating parameters. Parameter RF power Value 1550 W Sampling depth 8.0 mm Nebulizer gas flow rate 1.15 L/min Spray chamber temp 2 C Cell gas None Calibration A blank and four neptunium calibration standards from 100 to 2000 ng/l (ppt) were prepared in nitric acid (2% v/v, ltrapur, Merck, Germany ). The calibration curve obtained by ICP-QQQ showed excellent linearity over the calibrated range with a calibration coefficient of 1.0000 (Figure 3). As Np is essentially absent from the environment and does not occur as a typical reagent contaminant, the Background Equivalent Concentration (BEC) obtained was ~0.0009 ng/l (0.9 pg/l, ppq) and the Detection Limit (DL) was ~0.0031 ng/l (3.1 ppq). This illustrates the exceptionally low background and high ion transmission (sensitivity) of the ICP-QQQ when operating in MS/MS mode. Np Figure 2. Spectra of 100 ppt Np in a 10 ppm matrix sample solution obtained using ICP-QQQ in Single Quad mode (top) and MS/MS mode (bottom). MS/MS mode eliminates the peak tail on the low mass side of the intense 238 peak. Experimental Instrumentation The Agilent 8800* ICP-QQQ was configured with an SPS 4 autosampler, and the standard sample introduction system consisting of a Micromist nebulizer, quartz spray chamber, quartz torch and Ni interface cones. Instrument operating parameters are given in Table 1. Figure 3. Calibration curve for Np obtained by ICP-QQQ. * The Agilent 8800 ICP-QQQ has been superseded by the 8900 ICP-QQQ 3

Results and discussion Table 2. Measurement of Np in a series of matrix samples using ICP-QQQ and ICP-QMS. Sample Name Reported Np conc., ug/l 8800 ICP-QQQ 7900 ICP-QMS CPS Reported Np conc., ug/l 1 ppm - unspiked 0.0000 1.10 0.0016 570.48 1 ppm, 0.1 ppb Np 0.1021 14942.85 0.1018 36525.19 1 ppm, 1.0 ppb Np 1.0445 152806.38 1.0100 362304.66 10 ppm - unspiked 0.0000 0.83 0.0154 5519.75 10 ppm, 0.1 ppb Np 0.1029 15052.99 0.1152 41339.80 10 ppm, 1.0 ppb Np 1.0486 153402.27 1.0196 365764.86 100 ppm - unspiked 0.0000 3.97 0.1581 56728.76 100 ppm, 0.1 ppb Np 0.0997 14586.02 0.2494 89482.09 100 ppm, 1.0 ppb Np 0.9859 144228.95 1.0597 380137.27 CPS The Abundance Sensitivity performance of the ICP-QQQ in MS/MS mode was tested using a series of spiked and unspiked uranium solutions. Three sets of uranium solutions were prepared, at concentrations of 1, 10 and 100 mg/l (ppm). For each concentration level, the matrix solutions were measured unspiked, and with Np spikes at 0.1 and 1.0 µg/l (ppb). For comparison purposes, the samples were analyzed using an Agilent 8800 ICP-QQQ and an Agilent 7900 ICP-QMS, to assess the impact of the improved AS performance of the QQQ configuration. The results in Table 2 show that accurate recoveries were achieved for both Np spike levels in all of the matrix samples analyzed by ICP-QQQ even with :Np concentrations at a ratio of 1,000,000:1. In contrast, the Np results measured on the 7900 quadrupole ICP-MS show a small contribution from the matrix. This signal contributes to a false-positive result for Np in the higher matrix samples, including the unspiked matrices. While the signal only increased the apparent Np concentration by a small amount (sub-µg/l), the low level at which Np must be monitored means that this false signal is significant. The ICP-QMS results show that the interference effect is more pronounced with increasing matrix concentration, due to the relatively poor AS of ICP-QMS compared to ICP-QQQ. Conclusions ICP-MS is used successfully for the analysis of trace elements in a wide range of complex sample matrices. However, several challenging interferences remain, including the measurement of trace analytes that occur close to major or matrix element peaks. This study has shown that the superior abundance sensitivity provided by the ICP-QQQ s tandem quadrupole mass analyzer configuration (MS/MS) has practical benefits for the analysis of trace concentrations of Np at m/z in the presence of high concentrations of the adjacent major isotope of at m/z 238. Conventional quadrupole-icp-ms cannot resolve the overlap/peak tailing from the 238 isotope sufficiently to allow ultra-trace level analysis of Np; SF-ICP-MS also has insufficient abundance sensitivity to resolve the adjacent masses well enough to perform this analysis. 4

www.agilent.com/chem Agilent shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance or use of this material. Information, descriptions, and specifications in this publication are subject to change without notice. Agilent Technologies, Inc. 2017 Published December 19 2017 Publication number: 5991-6905EN