Ultrasensitive EPA Method 1694 with the Agilent 6460 LC/MS/MS with Jet Stream Technology for Pharmaceuticals and Personal Care Products in Water

Similar documents
EPA Method 1694: Analysis of Pharmaceuticals and Personal Care Products in Water

Determination of Pharmaceuticals in Water by SPE and LC/MS/MS in Both Positive and Negative Ion Modes Application

Agilent Standard Operating Procedure

Determination of Pharmaceuticals in Water by SPE and LC/MS/MS in Both Positive and Negative Ion Modes

Analysis of Pharmaceuticals & Personal Care Products by LC/MS

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Determination of Hormones in Drinking Water by LC/MS/MS Using an Agilent InfinityLab Poroshell HPH Column (EPA 539)

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

LC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Application Note. Abstract. Authors. Environmental

High Sensitivity HPLC Analysis of Perchlorate in Tap Water Using an Agilent 6460 Triple Quadrupole LC/MS System

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Analysis of Low-Calorie Sweeteners by Liquid Chromatography-Tandem Mass Spectrometry

Rapid method development to study plasma stability of diverse pharmaceutical compounds using Rapid Resolution LC and triple quadrupole MS

Agilent 6460 Triple Quadrupole LC/MS System with an Agilent 1290 Infinity LC For Multi-Plant Growth Regulator Analysis in Grapes

Sensitive Femtogram Determination of Aflatoxins B 1 , B 2 , G 1. and G 2. in Food Matrices using Triple Quadrupole LC/MS. Authors.

Accurate Mass Analysis of Hydraulic Fracturing Waters: Identification of Polyethylene Glycol Surfactants by LC/Q-TOF-MS

Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS

Accurate Mass Analysis of Hydraulic Fracturing Waters

Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry

Agilent ESI and APCI sources: for polar to non-polar compounds

Determination of Chlorinated Acid Herbicides in Soil by LC/MS/MS Application Note

Separation of Enantiomers of Amphetamine-Related Drugs and Their Structural Isomers

Determination of Pharmaceuticals in Environmental Samples

Improve Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application

Using UHPLC-Triple Quadrupole MS/MS to Detect the Presence of Bark Extract and Yohimbine Adulteration in Dietary Supplements and Botanicals

Emerging contaminants in marine invertebrates: concentrations and effects

LC/MS/MS of Fungicides and Metabolites in Apple Juice with Agilent Bond Elut Plexa and Poroshell 120

[ APPLICATION NOTE ] INTRODUCTION APPLICATION BENEFITS WATERS SOLUTIONS KEYWORDS

Identification and Quantitation of PCB Aroclor Mixtures in a Single Run Using the Agilent 7000B Triple Quadrupole GC/MS

Agilent 6400 Series Triple Quadrupole Users Workshop. MH QQQ Users workshop 2/21/2014 1

Quantitative Analysis of Water-Soluble B-Vitamins in Cereal Using Rapid Resolution LC/MS/MS. Application. Authors. Abstract.

LC/MS/MS of Fungicides and Metabolites in Orange Juice with Agilent Bond Elut Plexa and Poroshell 120

Analysis of Pharmaceuticals and Personal Care Products in River Water Samples by UHPLC-TOF

Identification and Quantitation of Pesticides in Chamomile and Ginger Extracts Using an Agilent 6460 Triple Quadrupole LC/MS system with Triggered MRM

materials analysis Solutions for Your Analytical Business Markets and Applications Programs

Ultrafast Analysis of Methadone and Metabolite EDDP in Urine by the Agilent RapidFire High-Throughput Mass Spectrometry System

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

Application Note. Author. Abstract. Food Testing & Agriculture. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Detection of Trace Level Pharmaceuticals in Drinking Water by Online SPE Enrichment with the Agilent 1200 Infinity Series Online-SPE Solution

Pharmaceuticals, Personal Care Products, and Endocrine Active Chemical Monitoring in Lakes and Rivers: 2013

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Screening of Pharmaceuticals and Personal Care Products in Effluents and Surface Waters with LCMS Q-TOF

Application Note. Authors. Abstract. Introduction. Environmental

Francisco Estuary Water, Sediments, and Mussels

Accurate Mass Measurement for Intact Proteins using ESI-oa-TOF. Application Note. Donghui Yi and Christine Miller Agilent Technologies

Bilag 3 Appendix B: Function tests

Determination of pesticides in baby food by UHPLC/MS/MS using the Agilent 1290 Infinity LC system and the Agilent 6460 triple quadrupole LC/MS

Separation of Explosives in EPA 8330: Column Choices Optimize Speed, Resolution, and Solvent Use. Application. Authors. Abstract.

Analysis of Cannabinoids and Amphetamines in Serum by RRLC/Triple Quadrupole Mass Spectrometry Using a Multimode Ion Source. Application.

Key Words Q Exactive Focus, Orbitrap, veterinary drugs, small molecule HRAM quantitation, small molecule HRAM screening, UHPLC, vdia

MS n Analysis With Fast Polarity Switching in the Agilent 1100 Series LC/MSD Trap SL. Application Note. Christine Miller Agilent Technologies

Aminoglycosides in Milk Using Agilent Bond Elut Plexa SPE, Agilent Poroshell 120, and LC/Tandem MS

Ultrafast Analysis of Buprenorphine and Norbuprenorphine in Urine Using the Agilent RapidFire High-Throughput Mass Spectrometry System

Exceptional Selectivity of Agilent ZORBAX Eclipse Plus Phenyl-Hexyl Columns to Separate Estrogens

Sensitive Screening of Pharmaceuticals and Personal Care Products (PPCPs) in Water Using an Agilent 6545 Q-TOF LC/MS System

MONITORING FOR PHARMACEUTICALS IN SURFACE WATER USING DIRECT AQUEOUS INJECTION ON THE AGILENT 6490 LC/QQQ

Multiresidue Analysis of 100 Pesticides in Food Samples by LC/Triple Quadrupole Mass Spectrometry Application

Developing a fast, generic method for rapid resolution LC with quadrupole MS detection. Application Note

New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses

High-Throughput Protein Quantitation Using Multiple Reaction Monitoring

Application Note. Abstract. Authors. Food Safety and Environmental

Taking Full Advantage of UHPLC with Agilent 6460A Triple Quadrupole MS. Outline

The Waters Acquity Ultra-Performance Liquid Chromatograph and the Micromass Quattro Premier Triple Quadrupole Mass Spectrometer

Anaylsis of Pesticide Residues in Rice Using Agilent Bond Elut QuEChERS AOAC Kit by LC-MS/MS Detection

LC/Q-TOF Workflows for Comprehensive Micropollutant Analysis

SAMHSA-Compliant LC/MS/MS Analysis of Phencyclidine in Urine with Agilent Bond Elut Plexa PCX and Agilent Poroshell 120

Pharmaceuticals and Chemicals of Concern in Rivers: Occurrence and Biological Effects

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)

Analyzing Compounds of Environmental Interest Using an LC/Q-TOF Part 1: Dyes and Pigments. Application. Introduction. Authors. Abstract.

Amphetamines, Phentermine, and Designer Stimulant Quantitation Using an Agilent 6430 LC/MS/MS

Measuring Drug-to-Antibody Ratio (DAR) for Antibody-Drug Conjugates (ADCs) with UHPLC/Q-TOF

The Analysis of Organophosphate Pesticides by LC/MS Application

Comprehensive Pesticide Analysis in Juice Using a Combination of GC/MS and LC/MS Methods

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

Fast Analysis of Illicit Drug Residues on Currency using Agilent Poroshell 120

Sensitive Detection of 2-MIB and Geosmin in Drinking Water

László Tölgyesi LC/MS scientist EFSC Demo Group. International Symposium on Food Safety and Quality: Applications of Nuclear and Related Techniques

Analysis of Biomarkers in Crude Oil Using the Agilent 7200 GC/Q-TOF

Abstract. Experimental Sample Preparation

Application Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors

LC/MS/MS Analysis of Pesticide Residues in Apples Using Agilent Chem Elut Cartridges

The Agilent 1260 Infinity Analytical SFC System with Time-of-Flight Mass Spectrometric Detection

The ultratrace determination of iodine 129 in aqueous samples using the 7700x ICP-MS with oxygen reaction mode

Simultaneous analysis for forensic drugs in human blood and urine using ultra-high speed LC-MS/MS

Analysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS

Determination of EU-Banned Disperse Dyes by LC/MSD TOF Application

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

Rapid Screening and Analysis of Components in Nonalcoholic Drinks Application

Using TOF for Screening and Quantitation of Sudan Red Colorants in Food Application

The Analysis of Fluoroquinolones in Beef Kidney Using HPLC Electrospray Mass Spectrometry Application

Application. Authors. Abstract. Introduction. Hydrocarbon Processing

Toxicity, Teratogenic and Estrogenic Effects of Bisphenol A and its Alternative. Replacements Bisphenol S, Bisphenol F and Bisphenol AF in Zebrafish.

Fast USEPA 8270 Semivolatiles Analysis Using the 6890/5973 inert GC/MSD with Performance Electronics Application

Agilent 6400 Series Triple Quadrupole LC/MS/MS Users Session

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

High-Speed Environmental Analysis Using the Agilent 7500cx with Integrated Sample Introduction System Discrete Sampling (ISIS DS)

Transcription:

Ultrasensitive EPA Method 1694 with the Agilent 6460 LC/MS/MS with Jet Stream Technology for Pharmaceuticals and Personal Care Products in Water Application Note Environmental Authors Imma Ferrer, E. Michael Thurman Center for Environmental Mass Spectrometry University of Colorado Boulder, CO USA Jerry Zweigenbaum Agilent Technologies, Inc. 2850 Centerville Road Wilmington, DE 19809-1610 USA Abstract An analytical method for screening and confirming the presence of 84 pharmaceuticals and 23 labeled standards in water samples for a total of 107 components was developed using the Agilent 6460 Triple Quadrupole Mass Spectrometer (Triple Quad MS) with Jet Stream Technology. The method was developed for the compounds in EPA Method 1694 and an additional 14 pharmaceuticals commonly found in wastewater. The results were compared to the Agilent 6410A Triple Quadrupole and an enhancement in limits of detection of 10 to 100 times was shown for the 6460. Also rapid resolution and fast chromatography were used to obtain the same or better quality separations for EPA Method 1694 with 1.8-µm columns. Four distinct chromatographic gradients and LC conditions were used according to the polarity and extraction of the different pharmaceuticals. The chromatographic conditions were then altered to show that the four gradients may be collapsed to only two chromatographic runs with no loss of sensitivity or accuracy of determination with a savings in time from 90 min to only 30 min total time. The method was evaluated for a treated wastewater effluent and five different pharmaceuticals were identified at levels as low as 1 ng/l. The new Jet Stream technology is a valuable new tool for pharmaceutical analysis of water and wastewater with excellent sensitivity and limits of detection.

Introduction The analytical challenge of measuring emerging contaminants in the environment has been a major research focus of scientists for the last 20 years. Pharmaceuticals are an important group of contaminants that have been targeted, especially in the last decade. In the area of pharmaceuticals and personal care products (PPCPs), there is one EPA method (although not yet promulgated) addressing the analysis of these analytes, which is EPA Method 1694 [1] published in December 2007. In this method, the standard EPA protocol uses solidphase extraction (SPE) for water samples followed by analysis with LC/MS using a tandem mass spectrometer with a single transition for each compound. Recently, we published an application note that was an improvement on this EPA Method 1694 because it uses two transitions for each analyte, which is a standard analytical protocol, while still meeting the chromatographic conditions specified by EPA with all Agilent columns [2]. This application note describes the latest new Agilent solution to this EPA method, which is demonstrated with the Agilent 6460 LC/MS Triple Quad with Jet Stream technology. The number of compounds in the method has been increased by 14, which include not only the standard analytes in EPA Method 1694 (70 analytes of their 74 - four were not available to us) but also 14 commonly found pharmaceuticals and 23 labeled internal standards for a total of 107 compounds. The chromatography has been shortened by reducing the analysis from 4 groups to 2 groups of analytes, in spite of the increased number of compounds. Furthermore, the analysis times have been reduced from a total of 90 min to less than 30 min, while achieving a 10 to 100 times increase in sensitivity, depending upon the analyte detected. The result is a robust analytical method for PPCPs in water that may be analyzed rapidly and sensitively while maintaining the highest analytical standards for correct analysis. Experimental Sample Preparation Pharmaceutical analytical standards were purchased from Sigma, (St. Louis, MO, USA). Individual pharmaceutical stock solutions (approximately 1000 µg/ml) were prepared in pure acetonitrile or methanol depending on the solubility of each individual compound, and stored at 18 ºC. From these solutions, working standard solutions were prepared by dilution with acetonitrile and water. Wastewater samples were collected from an effluent site in Boulder Creek (Boulder, CO) and extracted with Oasis HLB cartridges using a modified EPA protocol. One-liter water samples were extracted directly onto a 500-mg cartridge without ph adjustment, dried for 10 min with air, and eluted with 8 ml of methanol. The methanol was evaporated to 1 ml and analyzed directly by LC/MS/MS as described below. "Blank" wastewater extracts were used to prepare the matrix-matched standards for validation purposes. The wastewater extracts were spiked with the mix of pharmaceuticals at different concentrations (ranging from 0.1 to 500 ng/ml or ppb) and subsequently analyzed by LC/MS/MS. LC/MS/MS Conditions for Agilent 6460 with Jet Stream Technology The analytes were subdivided in groups (according to EPA protocol for sample extraction) and LC conditions for the chromatographic separation of each group are as follows for the standard EPA Method Analysis. LC Conditions for Group 1-Acidic extraction, positive electrospray ionization (ESI+) instrument conditions. Column: Agilent ZORBAX Eclipse Plus C-18 narrow bore, 2.1 mm 100 mm, 1.8 µm, p/n 959764-902 Column temp: 25 C Mobile phase: 10% ACN and 90% H 2 O with 0.1% HCOOH Flow-rate: 0.2 0.3 ml/min Gradient: t 0 = 10% ACN, 0.2 ml/min t 5 = 10% ACN, 0.2 ml/min t 6 = 10% ACN, 0.3 ml/min t 24 = 60% ACN, 0.3 ml/min t 30 = 100% ACN Injection volumes: 15 µl 2

LC Conditions for Group 2 Acidic extraction, positive electrospray ionization (ESI+) instrument conditions Column: Agilent ZORBAX Eclipse Plus C-18 narrow bore, 2.1 mm 100 mm, 1.8 µm, p/n 959764-902 Column temp: 25 C Mobile phase: 10% ACN and 90% H 2 O with 0.1% HCOOH Flow-rate: 0.2 ml/min Gradient: t 0 = 10% ACN t 10 = 10% ACN t 30 = 100% ACN Injection volumes: 15 µl LC Conditions for Group 3 Acidic extraction, negative electrospray ionization (ESI-) instrument conditions Column: Agilent ZORBAX Eclipse Plus C-18 narrow bore, 2.1 mm 100 mm, 1.8 µm, p/n 959764-902 Column temp: 25 C Mobile phase: 40% MeOH and 60% H 2 O with 0.1% ammonium formate ph 5.5 Flow-rate: 0.2 ml/min Gradient: t 0 = 40% MeOH t 0.5 = 40% MeOH t 7 = 100% MeOH Injection volumes: 15 µl LC Conditions for Group 4 Basic extraction, positive electrospray ionization (ESI+) instrument conditions. Column: Agilent ZORBAX Eclipse HILIC Plus narrow bore, 2.1 mm 100 mm, 3.5 µm, p/n 959793-901 Column temp: 25 C Mobile phase: 5% ACN and 5% H 2 O with 10 mm ammonium acetate, ph 6.5 Flow-rate: 0.25 ml/min Gradient: t 0 = 95% ACN t 9 = 70% ACN t 15 = 70% ACN Injection volumes: 15 µl LC Conditions for Group 5 Extra compounds commonly found in wastewater but not part of EPA Method 1694, positive electrospray ionization (ESI+) instrument conditions. All conditions are the same as in Group 1. Agilent Jet Stream conditions for the LC/MS/MS Model 6460. Gas heater: 250 C Gas flow: 8 L/min Nebulizer pressure: 35 psi Sheath gas heater: 300 C Sheath gas flow: 10 L/min V cap : 4000 V Nozzle voltage: 0 Delta EMV: 400 V Results and Discussion Optimization of LC/MS/MS conditions Method development for LC/MS with a triple quadrupole always consists of two parts. The first step was to optimize the fragmentor voltage for each of the pharmaceuticals studied in order to produce the largest signal for the precursor ion. Typically the protonated molecule was used for the precursor ion. Each compound was analyzed separately using an automated procedure (Agilent Optimizer software) to check the fragmentor at each voltage. The data was then selected for optimal fragmentor signal and each compound was optimized again to determine collision energies for both the quantifying and qualifying ions. The software does this automatically. Collision energies varied between 5 and 45 V. The energies were optimized for each of the ions and the voltages that gave the best sensitivity were selected. The list of PPCPs that were analyzed in EPA Method 1694 along with the additional 18 analytes and internal standards are shown in Table 1A to 1E along with the optimized MRM transitions used for this study. 3

Table 1A. MRM Transitions and MS Operating Parameters Selected for the Analysis of the Pharmaceutical Compounds in Group 1. In Bold are the Labeled Standards. Fragmentor MRM transitions Collision energy Compound voltage (m/z) (ev) Acetaminophen 90 152 > 110 15 152 > 65 35 13 C 2-15 N-Acetaminophen 90 155 > 111 15 155 > 93 25 Ampicillin 70 350 > 160 10 350 > 106 15 13 C 3 -Atrazine 120 219 > 177 15 219 > 98 25 Azithromycin 130 749.5 > 591.4 30 749.5 > 158 35 Caffeine 110 195 > 138 15 195 > 110 25 13 C 3 -Caffeine 110 198 > 140 15 198 > 112 25 Carbadox 80 263 > 231 5 263 > 130 35 Carbamazepine 110 237 > 194 15 237 > 179 35 Carbamazepine-d10 110 247 > 204 15 247 > 202 35 Cefotaxime 90 456 > 396 5 456 > 324 5 Ciprofloxacin 110 332 > 314 20 332 > 231 35 13 C 3-15 N-Ciprofloxacin 110 336 > 318 15 336 > 235 35 Clarithromycin 110 748.5 > 158 25 748.5 > 590 15 Cloxacillin 90 436 > 160 15 436 > 277 15 Codeine 154 300 > 165 41 300 > 215 21 Codeine-d3 162 303 > 165 45 303 > 61 25 Cotinine 90 177 > 98 25 177 > 80 25 Cotinine-d3 90 180 > 80 25 180 > 101 25 Dehydronifedipine 130 345 > 284 25 345 > 268 25 Digoxigenin 90 391 > 355 15 391 > 337 15 Digoxin No response, Na adduct Diltiazem 130 415 > 178 25 415 > 150 25 (Continued) 4

Fragmentor MRM transitions Collision energy Compound voltage (m/z) (ev) 1,7-Dimethylxanthine 90 181 > 124 15 181 > 99 15 Diphenhydramine 70 256 >167 15 256 > 152 35 Enrofloxacin 130 360 > 316 15 360 > 342 15 Erythromycin 90 734.5 > 158 35 734.5 > 576 15 13 C 2 -Erythromycin 90 736.5 > 160 25 736.5 > 578 15 Erythromycin Anhydrate 90 716.5 > 158 25 716.5 > 116 25 Flumequine 90 262 >174 35 262 > 244 15 Fluoxetine 90 310 > 148 5 Fluoxetine-d6 90 316 > 154 5 Lincomycin 110 407 > 126 25 407 > 359 15 Lomefloxacin 130 352 > 308 15 352 > 265 25 Miconazole 90 415 > 159 35 415 > 69 25 Norfloxacin 70 320 > 302 15 320 > 276 15 Ofloxacin 110 362 > 318 15 362 > 261 25 Oxacillin 70 402 > 160 15 402 > 243 5 Oxolinic Acid 90 262 > 244 15 262 > 216 25 Penicillin G 90 335 > 160 5 335 > 176 5 Penicillin V 70 351 > 160 5 351 > 114 25 Roxithromycin 130 837.5 > 679 15 837.5 > 158 35 Sarafloxacin 130 386 > 299 25 386 > 368 25 Sulfachloropyridazine 90 285 > 156 10 285 > 92 25 Sulfadiazine 110 251 > 156 15 251 > 92 25 Sulfadimethoxine 80 311 > 156 20 311 > 92 35 Sulfamerazine 110 265 > 156 15 265 > 92 25 Sulfamethazine 90 279 > 156 15 279 > 186 15 (Continued) 5

Fragmentor MRM transitions Collision energy Compound voltage (m/z) (ev) 13 C 6 -Sulfamethazine 90 285 > 186 25 285 > 162 25 Sulfamethizole 80 271 > 156 10 271 > 92 25 Sulfamethoxazole 110 254 > 156 15 254 > 92 25 13 C 6 -Sulfamethoxazole 110 260 > 162 15 260 > 98 25 Sulfanilamide 70 173 > 156 5 173 > 92 15 Sulfathiazole 108 256>156 9 256>92 21 Thiabendazole 130 202 > 175 25 202 > 131 35 Trimethoprim 110 291 > 230 25 291 > 261 25 13 C 3 -Trimethoprim 110 294 > 233 25 294 >264 25 Tylosin 110 916.5 > 174 35 916.5 > 772 35 Viginiamycin 110 526 > 508 5 526 > 355 15 6

Table 1B. MRM Transitions and MS Operating Parameters Selected for the Analysis of the Pharmaceutical Compounds in Group 2. Fragmentor MRM transitions Collision Compound Voltage (m/z) energy (ev) Anhydrochlortetracycline 122 461 > 444 13 461 > 410 13 Anhydrotetracycline 90 427 > 410 15 427 > 154 25 Chlorotetracycline 110 479 > 462 15 479 > 197 35 Demeclocycline 130 465 > 430 25 465 > 448 15 Doxycycline 110 445 > 428 15 445 > 154 25 4-Epianhydrochlortetracycline 134 461>444 13 461 > 426 13 4-Epianhydrotetracycline (EATC) 90 427 > 410 15 427 >105 35 4-Epichlortetracycline 134 479 > 462 17 479 > 197 17 4-Epioxytetracycline 130 461 > 444 13 461 > 426 17 4-Epitetracycline (ETC) 110 445 > 410 15 445 > 427 5 Isochlotetracycline 138 479 > 462 17 479 > 252 45 Meclocycline 110 477 > 460 15 Minocycline 90 458 > 441 15 Tetracycline (TC) 110 445 > 410 15 445 > 427 5 7

Table 1C. MRM Transitions and MS Operating Parameters Selected for the Analysis of the Pharmaceutical Compounds in Group 3. Fragmentor MRM transitions Collision Compound Voltage (m/z) energy (ev) Gemfibrozil 100 249 > 121 5 Gemfibrozil-d6 100 255 > 121 5 Ibuprofen 75 205 > 161 5 13 C 3 -Ibuprofen 75 208 > 163 5 Naproxen 75 229 > 169 25 229 > 170 5 13 C-Naproxen-d3 75 233 > 169 25 233 > 170 5 Triclocarban 100 313 > 160 10 313 > 126 25 13 C 6 -Triclocarban 90 319 > 160 5 319 > 132 25 Triclosan 75 287 > 35 5 13 C 12 -Triclosan 75 299 > 35 5 Warfarin 125 307 > 117 35 307 > 161 15 Warfarin-d5 90 312 > 161 15 312 > 255 25 Table 1D. MRM Transitions and MS Operating Parameters Selected for the Analysis of the Pharmaceutical Compounds in Group 4. Fragmentor MRM transitions Collision Compound Voltage (m/z) energy (ev) Albuterol (Salbutamol) 90 240 > 148 15 240 >166 5 Cimetidine 100 253 > 159 10 253 > 95 25 Metformin 80 130 > 60 10 130 >71 25 Ranitidine 110 315 > 176 15 315 > 130 25 8

Table 1E. MRM Transitions and MS Operating Parameters Selected for the Analysis of the Pharmaceutical Compounds in Group 5, which are the Additional Commonly Detected Pharmaceutical Analytes Added to the Method Fragmentor MRM transitions Collision Compound Voltage (m/z) energy (ev) Amphetamine 70 136 > 91 13 136 > 119 5 Amphetamine-d5 74 141 > 93 13 141 > 124 5 Atenolol 134 267 > 145 21 267 > 190 13 Clonidine 150 230 > 44 25 230 > 213 21 Dextromethorphan 152 272 > 171 41 272 > 147 29 Diazepam 162 285 > 154 25 285 > 193 33 Diazepam-d5 162 290 > 198 33 290 > 154 25 Diclofenac 83 294 > 250 5 83 294 > 214 21 Furesemide 95 329 > 285 13 95 329 > 205 21 Hydrocodone 158 300 > 199 29 300 > 171 41 Hydrocodone-d6 166 306 > 202 29 306 > 174 41 Meprobamate 70 219 > 158 5 219 > 55 20 Metoprolol 136 268 > 116 13 268 > 56 29 Nordiazepam 158 271 > 140 25 271 > 165 25 Oxycodone 134 316 > 298 13 316 > 241 25 Oxycodone-d6 134 322 > 304 13 322 > 247 29 Propranolol 122 260 > 116 13 260 > 56 29 Sertaline 88 306 > 159 25 306 > 275 5 13 C 6-2,4,5-Trichlorophenoxyacetic acid 110 259 > 201 5 259 > 165 25 Chromatographic separation was done independently for each group and a dwell time of 10 msec was used for every MRM transition. Figures 1A to 1D show the chromatograms corresponding to 100 ppb standard on column for all the pharmaceuticals studied. Extracted ion chromatograms were overlaid for each one of the target analytes according to their respective protonated molecule and product-ion MRM transitions. 9

10 5 5.5 +ESI MRM Frag=90.0V CID@15.0 (436.0000 -> 277.0000) Group 1_10 ppb_mrm segmentsnew column.d 1 12 23 3 5 4.5 4 3.5 3 2.5 2 1.5 1 0.5 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 Counts vs. acquisition time (min) Figure 1A. MRM extracted chromatogram for pharmaceuticals in Group 1. Three time segments were used in this chromatographic separation using the 1.8 µm column and the Agilent Stream Technology. Concentrations were all at 10 ppb. 10 4 2.8 2.6 2.4 2.2 2 1.8 1.6 1.4 1.2 1 0.8 0.6 0.4 0.2 +ESI MRM Frag=110.0V CID@** (445.0000 -> 427.0000) Group 2_10 ppb_mrm segmentsnew column.d 1 1 1.2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 Counts vs. acquisition time (min) Figure 1B. MRM extracted chromatogram for pharmaceuticals in Group 2 at a concentration of 10 ppb. 10

10 4 1.6 1.5 1.4 1.3 1.2 1.1 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 -ESI MRM Frag=100.0V CID@** (313.0000 -> 126.0000) Group 3_10 ppb_mrm segments.d 1 1 8.9 9.2 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 6.5 7 7.5 8 8.5 9 9.5 10 10.5 Counts vs. acquisition time (min) Figure 1C. MRM extracted chromatogram for pharmaceuticals in Group 3 at a concentration of 10 ppb. 10 4 3.2 3 2.8 2.6 2.4 2.2 2 1.8 1.6 1.4 1.2 1 0.8 0.6 0.4 0.2 +ESI MRM Frag=80.0V CID@** (130.0000 -> 71.0000) Group 4_1 ppb_mrm segments.d 1 1 12.8 4.6 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 6.5 7 7.5 8 8.5 9 9.5 10 10.5 11 11.5 12 12.5 13 13.5 14 14.5 15 15.5 Counts vs. acquisition time (min) Figure 1D. MRM extracted chromatogram for pharmaceuticals in Group 4 at a concentration of 1 ppb. 11

Simplification of EPA Method 1694 Because EPA Method 1694 consists of four different groups, this means that four analyses are required with a total time of approximately 90 min. Therefore, the two goals in this application note are to simplify the chromatography to two analysis groups with the minimum time, and to increase the sensitivity to the maximum possible for the method. To accomplish this, the following changes to the method were made. First Groups 1, 2, 4, and 5 (additional commonly found analytes) were combined into one chromatographic run using the 1.8 µm Eclipse-C18 column, which gave good resolution for not only the EPA target analytes but also the 14 commonly found PPCPs in Group 5. This made our new Group I consist of 35 analytes and internal standards. These compounds were analyzed by positive electrospray in a 20-min run. The second group (Group II) consisted of six analytes with internal stan- dards, which were the negative electrospray analytes in a 10-min run. While it is possible to combine both groups and do positive and negative ion switching at the same time, this is not a recommended procedure. It is necessary to use the same mobile phase (water with 0.1% formic acid/acetonitrile) for both analyses which results in a lower sensitivity for negative-ion analytes. Therefore, we recommend two groups but make use of fast chromatography for the negative ions in the original Group III. Thus, the total analysis time is reduced from 90 to 30 min, which is three times faster without loss of sensitivity or reliability of detection while increasing the number of analytes by about 25%. Figures 2A and 2B show the chromatography for the new Group I and Group II analytes using the 1.8-µm columns and the combination of extended peak capacity in Group I and the fast chromatography of Group II. 10 5 6.5 -ESI MRM Frag=75.0V CID@5.0 (205.0000 -> 161.0000) 10 ppb_all Groups+Extras.d 1 1 2 2 3 3 4 6 5.5 5 4.5 4 3.5 3 2.5 2 1.5 1 0.5 22.4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Counts vs. acquisition time (min) Figure 2A. New Group I analytes in positive ion electrospray. This group includes the original Group 1, 2, and 4 of EPA Method 1694 plus 14 commonly found pharmaceuticals for a total of 85 compounds, with internal standards. 12

-ESI MRM Frag=75.0V CID@5.0 (205.0 -> 161.0) Group3_C18_speed grad_5ul.d 10 2 1 0.95 0.9 0.85 0.8 0.75 0.7 0.65 0.6 0.55 0.5 0.45 0.4 0.35 0.3 0.25 0.2 0.15 0.1 0.05 0 2.4 2.5 2.6 2.7 2.8 2.9 3 3.1 3.2 3.3 3.4 3.5 3.6 3.7 3.8 3.9 4 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 5 5.1 5.2 5.3 5.4 Counts (%) vs. acquisition time (min) Figure 2B. Fast chromatography showing the analytes in the new Group II in negative ion using a 6-min run with 1.8-µm column. Furthermore, we compared the increase in sensitivity and the lower detection limits (LODs) possible with the new Agilent Jet Stream Technology. The Agilent Jet Stream uses a sheath gas to increase the number of ions that are directed into the source of the mass spectrometer. This is accomplished by increasing analyte ionization and capture using heated thermal gradient focusing, which employs a super-heated nitrogen sheath gas to increase desolvation efficiency in electrospray and reduce background ions. Figure 3 shows how the Jet Stream Technology works. 13

Figure 3. Example of how the Jet Stream Technology works. The result of the Jet Stream Technology is that there is approximately a 5 to 10 times increase in the number of ions that are directed to the lens of the first octopole of the mass spectrometer. This results in an appreciable increase in sensitivity. Accompanying this is the individual effects of the analytes themselves. For example, each analyte has its own ionization efficiency, which is combined with the effects of its surface activity, its ability to accept or donate a proton, and its stability in the stream with electrospray potentials of 4000 volts. These combined effects increase the sensitivity and limit of detection of the PPCP analyte. We tested each of 70 analytes between the two instruments, the 6410A Triple Quad and the 6460 Triple Quad and the data from this comparison is shown in Table 2 with the original EPA groups (Groups 1 to 4). The solution of these compounds were injected directly with no concentration. 14

Table 2. PPCPs Analyzed by Group According to EPA Method 1694. Limits of Detection are Shown for Two Triple Quadrupoles, the Model 6410 and the Model 6460 with Agilent Jet Stream Technology (Note: 4 methyl esters were added to this table as compounds that form in the standard solution and are not part of the official EPA Method 1694.) LOD 6460 LOD 6410 Increase in LOD Compound (µg/l) (µg/l) (times) Acetaminophen 0.1 1.0 10 Ampicillin 0.6 5.0 8 Azithromycin 6.0 100 16 Caffeine 0.5 5 10 Carbadox 0.3 10 33 Carbamazepine 0.06 1.0 16 Cefotaxime 2 50 25 Ciprofloxacin 0.5 10 20 Clarithromycin 0.1 10 100 Cloxacillin 3.0 10 3 Cloxacillin Me-Ester 3.0 10 3 Codeine 0.3 10 33 Cotinine 0.05 1.0 20 Dehydronifedipine 0.03 1.0 33 Digoxigenin 0.4 2.0 5 Diltiazem 0.05 0.5 10 1,7-Dimethylxanthine 0.6 5.0 8 Diphenhydramine 0.05 0.2 4 Enrofloxacin 0.3 5.0 16 Erythromycin 0.3 10 30 Erythromycin Anhydrate 0.3 10 30 Flumequine 0.05 2.0 40 Fluoxetine 0.2 8.0 40 Lincomycin 0.05 1.0 20 Lomefloxacin 0.4 5.0 12 Miconazole 0.5 5.0 10 Norfloxacin 1.0 10 10 Ofloxacin 0.4 5.0 12 Ofloxacin Me-Ester 0.4 5.0 12 Oxacillin Oxolinic Acid 0.03 1.0 33 Penicillin G 1.0 5.0 5 Penicillin G Methyl Ester 1.0 5.0 5 Penicillin V 1.0 5.0 5 Penicillin V Methyl Ester 1.0 5.0 5 Roxithromycin 0.5 10 20 Sarafloxacin 0.5 5.0 10 Sulfachloropyridazine 0.2 5.0 25 (Continued) 15

LOD 6460 LOD 6410 Increase in LOD Compound (µg/l) (µg/l) (times) Sulfadiazine 0.5 5 10 Sulfadimethoxine 0.05 2.0 40 Sulfamerazine 0.1 3.0 30 Sulfamethazine 0.3 5.0 16 Sulfamethizole 0.3 3.0 10 Sulfamethoxazole 0.2 2.0 10 Sulfanilamide 4.0 20 5 Sulfathiazole 0.4 5.0 12 Thiabendazole 0.05 5.0 100 Trimethoprim 0.5 3.0 6 Tylosin 6.0 100 16 Virginiamycin 0.4 5 12 Group 2 Compounds. LOD Jetstream LOD 6410 Increase in LOD Compound 6460 (µg/l) (µg/l) (times) Anhydrochlortetracycline 5.0 50 10 Anhydrotetracycline 1.0 50 50 Chlorotetracycline 0.5 10 20 Demeclocycline 4.0 100 25 Doxycycline 1.0 60 60 4-Epianhydrochlortetracycline 5.0 30 6 4-Epianhydrotetracycline 0.5 30 60 4-Epichlortetracycline 1.0 80 80 4-Epioxytetracycline 5.0 100 20 4-Epitetracycline 1.0 50 50 Isochlotetracycline 5.0 10 2 Minocycline 20 100 5 Tetracycline 0.8 60 75 Group 3 Compounds. LOD Jetstream LOD 6410 Increase in LOD Compound 6460 (µg/l) (µg/l) (times) Gemfibrozil 0.1 0.1 1 Ibuprofen 5.0 5.0 1 Naproxen 1.0 1.0 1 Triclocarban 0.1 0.1 1 Triclosan 1.0 1.0 1 Warfarin 0.1 0.1 1 16

Group 4 Compounds. Compound LOD Jetstream 6460 (µg/l) LOD 6410 (µg/l) Increase in LOD (times) Albuterol 0.05 0.05 Cimetidine 0.02 0.1 5 Metformin 0.05 0.1 2 Ranitidine 0.08 0.5 6 The result of this comparison shows that the Agilent Jet Stream technology increases the sensitivity for the PPCPs by at least 10 times and for many compounds this increase is on the order to 20 to 30 times. The detection limits for the majority of the PPCPs of EPA Method 1694 is in the ng/l or ppt range (approximately 50 of the 70 compounds or 71%). With these low LODs, it is possible to routinely monitor the majority of the PPCPs of EPA Method 1694 at the ng/l level or lower using a 1-L water sample and concentrating to 1-mL as directed by the EPA method. Figure 4. 1 Wastewater Analysis To confirm the suitability of the method for analysis of real samples, matrix-matched standards were analyzed in a wastewater matrix from an effluent site, at eight concentrations (0.1, 0.5, 1, 5, 10, 50, 100, and 500 ng/ml or ppb concentrations). Figure 4 shows an example standard curve for sulfamethoxazole in the wastewater matrix. In general, all compounds gave linear results with excellent sensitivity over three orders of magnitude, with r2 values of 0.99 or greater. Calibration curve for sulfamethoxazole in a wastewater matrix using a six point curve from 0.1 to 100 ng/ml (ppb) using a linear fit with no origin treatment. Note how the software displays the ion ratios in the proper boundaries. 17

Finally, a "unspiked" wastewater sample was analyzed and the presence of 5 pharmaceuticals: carbamazepine, cotinine, diphenhydramine, thiabendazole, and trimethoprim could be confirmed with two MRM transitions. Figure 5 shows the ion ratios of the qualifying and the quantifying ion for two of these compounds in the wastewater extract. As shown in Figure 5 in the two ion profiles, both pharmaceuticals were easily identified in this complex matrix due to the selectivity of the MRM transitions and instrument sensitivity. 10 4 + MRM (237.0000 -> 194.0000) Boulder WWO_Group 1_2 transitions.d 2 3 12 3 2 1 0 10 3 + MRM (237.0000 -> 179.0000) Boulder WWO_Group 1_2 transitions.d 23 12 6 4 2 Carbamazepine 237=>194 15 16 17 18 19 20 21 22 23 24 25 26 Counts vs. acquisition time (min) Carbamazepine 237=>179 10 3 + MRM (256.0000 -> 167.0000) Boulder WWO_Group 1_2 transitions.d 2 3 7 6 Diphenhydramine 5 4 256=>167 3 2 1 0 10 3 + MRM (256.0000 -> 152.0000) Boulder WWO_Group 1_2 transitions.d 2 3 2 1 15 16 17 18 19 20 21 22 Counts vs. acquisition time (min) Diphenhydramine 256=>152 0 15 16 17 18 19 20 21 22 23 24 25 26 Counts vs. acquisition time (min) 0 15 16 17 18 19 20 21 22 Counts vs. acquisition time (min) Figure 5. MRM chromatograms of a wastewater sample for carbamazepine and diphenhydramine using 2 transitions. 18

Conclusions The results of this study show that the Agilent 6410 and 6460 Triple Quadrupoles are robust, sensitive, and repeatable instruments for the study of pharmaceuticals in water samples, using high throughput methods. The Jet Stream Technology will add another 10 to 20 times sensitivity for the PPCP compounds. It will also allow routine analysis at the ng/l or ppt level or lower in wastewater matrices using a 1-L water sample and concentrating to 1-mL as outlined in EPA Method 1694. Furthermore, we have shown that the combination of MRMs and rapid resolution will speed up the analysis times for pharmaceuticals in EPA Method 1694 from over 90 min to approximately a 30-min analysis time. Finally, the analysis of 18 commonly found pharmaceuticals and internal standards were added to the method for a total of 107 compounds. References 1. EPA Method 1694: Pharmaceuticals and personal care products in water, soil, sediment, and biosolids by HPLC/MS/MS, December 2007, EPA-821-R-08-002. 2. Ferrer, I., Thurman, E.M., Zweigenbaum, J.A., 2008, Application Note 5989-9665EN, EPA Method 1694: Agilent's 6410A solution LC/MS/MS solution for pharmaceuticals and personal care products in water, soil, sediment, and biosolids by HPLC/MS/MS. For More Information For more information on our products and services, visit our Web site at www.agilent.com/chem. 19

www.agilent.com/chem Agilent shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. Information, descriptions, and specifications in this publication are subject to change without notice. Agilent Technologies, Inc., 2010 Printed in the USA November 16, 2010 5990-4605EN