DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

Similar documents
DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

PRODUCT CATALOGUE PREssURE switch

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DS 200 DS 200 DRUCK & TEMPERATUR LEITENBERGER GMBH. Electronic Pressure Switch. Stainless Steel Sensor. Electronic Pressure Switch

Pressure transmitters for industrial applications MBS 32 and MBS 33

ED 701 General Industry Pressure Transmitter

BTE5000 / PTE5000 / PTU5000 Series Precision differential pressure transmitters

Hydraulic Pressure NAH Applications. Features. New generation available - refer to

Pressure Transmitter ED 701

Industrial Pressure Transmitter

Industrial Pressure Transmitter

Operating instructions Pressure sensor PN / / 2007

Operating Instructions for Digital Manometer. Model: MAN-SD

Field IT 50T Series Transmitters

RoHS. Versatile. X g. X 2 e

Fitting PS P - B - R2

Sensors for pressure control OsiSense XMLR

T20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en

BTEL5000 / PTUL5000 Series Precision very low differential pressure transmitters

THM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist

Relative pressure transmitter type 520

E8EB-N0C2B E8EB-N0B2B

all stainless steel transducer multimedia compatibility

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

D5.2 Type. Draw wire mechanics with incremental encoder. Measuring length max. 2 m. Compact and simple. Order code draw wire encoder

Pressure. 1 Fitting PA R - N R2

PHOENIX CONTACT - 04/2016. Features

compact ejector, Series ECS with release valve with silencer with non-return valve, With filter vacuum switch: electronic 1x PNP and 1x analog

S95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

PG-200/PG-208 PRESSURE GAUGES P G G P P

Digital display Pressure range ON/OFF output Linear output Model No Positive pressure 0 to 98 kpa (0 to 1 kgf/cm 2 ) NPN open collector o 1 to o5

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

Compact and low-cost monitoring of conductive liquids. Magnetic-inductive flow metering from ifm.

Z7A. Load cells. Special features. Data sheet. Wiring code

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

Conductivity sensor for hygienic applications

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

CALYS 80P. Field pressure calibrator with high accuracy 0.01%

ISEmax CAM40/CAS40. Technical Information

S95.3U02 / S95.3U12. Head mounted temperature transmitters, HART programmable, Pt 100 (RTD), thermocouples, electrical isolation

AIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control

HMA Series Amplified pressure sensors

Usage limitations and accuracies of platinum resistance thermometers (DIN EN 60751:2009) in industrial applications

W 9 L: Laser photoelectric switches: small, light and reliable

Field mounted Temperature Transmitter TF212/TF212-Ex

Differential Pressure Switch

Absolute encoders multiturn

HME Series Amplified pressure sensors

SCTP20 Programmable 2-Wire Temperature Transmitter, Head Mount

4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE)

Benefits/Application. Very high-cycle fatigue resistant up to 80 % of nominal load. Easy assembling, lots of possibilities. Options/Accessories

HYGRASGARD KFF KFTF HYGRASGARD AFF AFTF HYGRASGARD AFF - LC AFTF - LC

Direct-operated 2/2-way solenoid valves Type EV210B

Smartec Pressure Sensor (bridge output)

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%

Pressure Measurement Single-range transmitters for general applications

Linear measuring technology

/2 way valves (solenoid actuated diaphragm with forced lifting) 1/4... 2

Cooling Water Flow Regulator

Thermal Mass Flow Meter for Gases

DRS 61: Incremental encoders, number of lines and zero pulse width freely programmable DRS 60: Incremental Encoders with Zero-Pulse-Teach

ZF Series Force Transducers

Operating instructions Vortex flow meter. SVxxx / / 2015

Benefits/Application. For static and dynamic tensile and compressive forces. Easy assembling, lots of possibilities. Options/Accessories

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1BVW S/08

Pressure Display Controller

Linear actuator Econom 2. Our intelligent model: Econom 2. Econom 2

RCO Series Precision compensated pressure sensors

BMXART0814 analog input module M340-8 inputs - temperature

Freescale Semiconductor

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER

14:1400 (0206) KRAL Volumeter - OMG

SINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol

V 12: Miniature photoelectric switches in M 12 housings

Solenoid valves Type EVUL

Benefits/Application. Very high-cycle fatigue resistant up to 100 % of nominal load. Extremely robust against side forces and bending moments

MODEL: R7K4FML3. Remote I/O R7K4F Series. POWER INPUT DC power R: 24 V DC (Operational voltage range: ±10 %; ripple 10 %p-p max.)

HR-Z SERIES Mild Radiation Resistance LVDT

Capacitive Sensors. Contents

DVZ. Vortex Flowmeter Compact. for low viscosity liquids. Range: l/min. Accuracy: ±2.5% of full scale. p max : 20 bar; t max : 80 C

CoriolisMaster FCB130, FCB150, FCH130, FCH150 Coriolis mass flowmeter

DATA SHEET. Thermocouple module with digital I²C-Interface - THMOD-I²C. Characteristic features. Areas of application. Features.

FLOW SENSOR FOR LIQUID MEDIA Serie 210

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22)

TOP Transfer. Data Sheet. Force transfer standard. Special characteristics. D 20.TOPTRANS.10 en

TF 212 / TF 212-Ex. Field mounted temperature transmitter, Profibus PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels. ABB Instrumentation

Dimensional drawing face mount flange radial. R = bending radius min. 40 mm. Dimensional drawing face mount flange axial

ORDERING INFORMATION # of Ports Pressure Type Device Name

TURQUOISE SWITCHES V TYPE (ABV)

Your Partner in Environment Monitoring

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Non-Contact Safety Systems CMS

Direct-operated 2/2-way compact solenoid valves Type EV210A

VK2 volume flow controller Overview

Transcription:

DS 00 Electronic Pressure Switch with IO-Link interface Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Digital output signal IO-Link according to specification V. Smart sensor profile Data transfer 8. kbaud contacts Analog output (optional) 0 ma or 0 0 V Special characteristics indication of measured values on a -digit LED display rotatable and configurable display module Parameter settings via IO-Link or menu (VDMA-conform) Optional versions different mechanical connections specific versions The DS 00 is equipped with an IO-Link interface as standard in order to exchange process data, diagnostic reports and status messages with a superordinate control level. The parameters are set either also via the control level or via the VDMA-compliant menu system, which can be carried out at a local level using keys. The DS 00 is designed for the mechanical engineering and plant engineering sectors. A large number of inch threads, metric threads or NPT threads are available to users in order to ensure optimum integration in the application. In addition, unusual display positions can be compensated to the multiple rotatability of the display so that the user is able to read the vital information without any problems. Preferred areas of use are Plant and Machine Engineering - machine tools - pneumatic plants - hydraulic plants BD SENSORS GmbH BD-Sensors-Straße Phone +9 (0) 9 5 / 98-0 www.bdsensors.com D - 9599 Thierstein Fax +9 (0) 9 5 / 98 - info@bdsensors.com

DS 00 Input pressure range Nominal pressure gauge [bar] -... 0 0.0 0.6 0.5 0.0 0.60.6.5 6 Nominal pressure abs. [bar] - - - - 0.0 0.60.6.5 6 Overpressure (static) [bar] 5 0.5 5 5 0 0 0 0 Burst pressure [bar] 7.5.5.5.5 7.5 7.5 5 5 5 50 Nominal pressure gauge / abs. [bar] 0 6 5 0 60 00 60 50 00 600 Overpressure (static) [bar] 0 80 80 05 0 0 600 000 000 000 Burst pressure [bar] 50 0 0 0 0 0 000 50 50 800 Vacuum resistance P N bar: fully vacuum resistant P N < bar: on request Contact Voltage supply Standard Optional Switching current 00 ma Accuracy of switching points ± 0.5 % FSO Repeatability ± 0. % FSO Switching frequency max. 00 Hz Switching cycles > 00 x 0 6 Delay time Analog output (optional) V S = 8... 0 V DC Output signal Output signal IO-Link / SIO (PNP or NPN) + PNP contact IO-Link / SIO (PNP or NPN) + NPN contact (on request) 0.0 50.0 sec Output signal Output signal Voltage (-wire) IO-Link / SIO (PNP or NPN) + 0... 0 V permissible load: R min 0 k Current (-wire) IO-Link / SIO (PNP or NPN) + 0 ma permissible load: R max 0 Accuracy nominal pressure 0. bar: ± 0.5 % FSO nominal pressure < 0. bar: ± 0.5 % FSO Influence effects supply: 0.05 % FSO load: 0. % FSO Long term stability ± 0. % FSO / year at reference conditions Response time < msec accuracy according to IEC 60770 limit point adjustment (non-linearity, hysteresis, repeatability) Thermal effects (Offset and Span) Nominal pressure P N [bar] - 0 < 0.0 0.0 > 0 Tolerance band [% FSO] ± 0.75 ± ± ± 0.75 in compensated range [ C] -0... 85 0... 70-0 85 0 70 Permissible temperatures Permissible temperatures medium: -0... 5 C electronics/environment: -0... 85 C storage: -0... 00 C Electrical protection Short-circuit protection permanent Reverse polarity protection no damage, but also no function Electromagnetic compatibility emission and immunity according to EN 66 IO-Link Interface IO-Link.; Slave Data transfer COM, 8. kbaud Mode SIO / IO-Link Standard IEC 6-9 Mechanical stability Vibration 0 g / 5 Hz khz according to DIN EN 60068--6 Shock 500 g / ms ec according to DIN EN 60068--7

DS 00 Materials Pressure port / Housing stainless steel.0 (6L) Display housing standard: PA 6.6 Seals (media wetted) standard: FKM option: EPDM others on request Diaphragm stainless steel.5 others on request Media wetted parts pressure port, seal, diaphragm Miscellaneous Display -digit, red LED display, digit height 7 mm, range of indication -999... +9999, visible range.5 x 0.5 mm, LED s for unit switching (bar, mbar, PSI, MPa) status display contact: contact : LED, green, contact : LED, yellow Operation buttons / functions according to VDMA 57- Turn-on time 0 msec Weight approx. 0 g Current consumption < 0 ma Protection class IP 65 IP67 Installation position any CE-conformity EMC Directive: 0/0/EU Pressure Equipment Directive: 0/68/EU (module A) Pressure transmitters are calibrated vertically with pressure port downwards. Changing the installation position could lead to minor zero offsets for pressure ranges P N bar. This directive is only valid for devices with maximum permissible overpressure > 00 bar. Wiring diagrams -wire-system (IO-Link / SIO with contact) -wire-system (IO-Link / SIO with analogue output) Pin configuration Electrical connections Mx (-pin) metal (without analogue output) Mx (-pin) metal (with analogue output) supply + supply signal + communication / contact contact - shield pressure port pressure port -

DS 00 Mechanical connections (dimensions in mm) standard option G/" DIN 85 G/" DIN 85 internal thread G/" DIN 85 G/" EN 87 G/" EN 87 not possible for nominal pressure PN > 0 bar and for vacuum ranges; for G/ flush absolute pressure on request /" NPT /" NPT G/" DIN 85 G/" DIN 85 flush flush 06 BD SENSORS GmbH The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials. Phone +9 (0) 9 5 / 98-0 www.bdsensors.com Fax +9 (0) 9 5 / 98 - info@bdsensors.com DS00_E_9076

Ordering code DS 00 DS 00 - - - - - - - - Pressure gauge in bar absolute in bar 7 9 7 9 Input [bar] 0.0 0 0 0 0.6 6 0 0 0.5 5 0 0 0.0 0 0 0 0.60 6 0 0 0.0 0 0.6 6 0.5 5 0.0 0 0 6.0 6 0 0 0 0 0 6 6 0 5 5 0 0 0 0 60 6 0 0 00 0 0 60 6 0 50 5 0 00 0 0 600 6 0 0-0 X 0 9 9 9 output IO-Link / SIO I O IO-Link / SIO + 0 0 V / analogue I IO-Link / SIO + 0 ma / analogue I 7 contact x PNP x NPN x PNP x NPN 5 6 consult Accuracy standard for P N 0. bar 0.5 % standard for P N < 0. bar 0.5 % 5 Electrical connection Male plug Mx (-pin) / metal M L 9 9 Mechanical connection G/" DIN 85 G/" EN 87 G/" DIN 85 G/" DIN 85, internal thread G/" EN 87 0 0 0 0 0 0 J 0 0 0 0 G/" DIN 85 with flush sensor F 0 0 G/" DIN 85 with flush sensor K 0 0 /" NPT /" NPT N 0 0 N 0 9 9 Seals FKM EPDM Special version standard 0 0 0 9 9 absolute pressure possible from 0. bar possible in combination with contact code, 6 possible in combination with contact code, 5 not possible for nominal pressure P N > 0 bar; also not possible for vacuum ranges; for G/ flush nominal pressure abs. on request 05.0.0 This dokument contains product specification; properties are not guaranteed. Detailed information about options are defined in the datasheet. Subject to change without notice.