New Test Results For Physical Separation Of Tritium From Noble Gases And It s Implications For Sensitivity And Accuracy In Air And Stack Monitoring

Similar documents
New Developments in Tritium Monitors

FEATURES: CAM-TC CAM-TCI

TOTAL 6 STACK MONITORS ~ GAS, PARTICULATE GROSS BETA-GAMMA ~ IODINE ~ TRITIUM ~ C-14

Permeation Measurement Testing Techniques. Michelle Stevens MOCON, Inc.

Monitoring Tritium in Air Containing Other Radioactive Gases


A Fast Responding Continuous Tritium-in-Air Monitor with Multi Stream Sampling for Area Monitoring

Confirmation of Heat Generation during Hydrogenation of Oil

COPLEY S C I E N T I F I C. A multi-function aerosol system with aerosol generation, classification and monitoring capabilities for:

CALIBRATION. Calibration. General Principles & Theory, Equipment Considerations. Copyright Caltech 2014

Principles of Food and Bioprocess Engineering (FS 231) Solutions to Example Problems on Psychrometrics

Humidity Calibration Solutions

Energy loss of alpha particles - Prelab questions

DISCLAIMER. Portions of this document may be illegible in electronic image products. Images are produced from the best available original document.

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

MICHELL TECHNOLOGIES FOR MOISTURE. Calibration. General Principles & Theory, Equipment Considerations

VALIDATION STUDY OF FTIR-BASED EMISSIONS MEASUREMENTS AT A MUNICIPAL WASTE COMBUSTOR

Atmospheric Analysis Gases. Sampling and analysis of gaseous compounds

Vaisala DRYCAP Hand-Held Dewpoint Meter DM70. Fast Response - Low Maintenance

FYSP106/K3 GEIGER & MÜLLER TUBE. 1 Introduction. 2 The equipment

Response Characteristics of Dew Point Sensor with Aluminum Oxide by means of Correlation between Purging Rate and Tube Length

Reliable, fast and accurate WVTR measurement technology. Dr. Jörg Koch SEMPA SYSTEMS GmbH

TRITIUM RECOVERY FROM WASTE USING A PALLADIUM MEMBRANE REACTOR

Measurement of Conductivity of Liquids

Edgetech Instruments Inc.

CHLORINE THEORY & MEASUREMENT

EXPERIMENTAL AND NUMERICAL STUDIES OF A SPIRAL PLATE HEAT EXCHANGER

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

Audit Report. Group photo taken during the audit day July 4, Pha Din Station. General Conclusion:

Chlorine and Hydrogen Chloride Monitoring Utilizing Ion Mobility Spectroscopy (IMS)

The RAID-M had the highly sensitive TDI library in Library A of the instrument as shown in Table 1. Table 1: Highly sensitive TDI library in ppb.

LECTURE 5 SUMMARY OF KEY IDEAS

He-3 Neutron Detectors

THE APPLICATION OF PROCESS MASS SPECTROMETRY TO FUMED SILICA PRODUCTION

Explaining Periodic Trends. Saturday, January 20, 18

- A spark is passed through the Argon in the presence of the RF field of the coil to initiate the plasma

Introduction to Heat and Mass Transfer

Gas-filled Detectors

IEC Tritium Standard

The Vacuum Case for KATRIN

Intercomparison of Mobility Particle Size Spectrometers

NON-METHANE ORGANIC CARBON ANALYZER (NMOC Method 25)

Humidity Calibration Solutions

ELEMENT2 High Resolution- ICP-MS INSTRUMENT OVERVIEW

Techniques for Fast Measurements of Low Dewpoint in Portable Hygrometers

Advanced Tritium Recovery System

Confirmation of Heat Generation during Hydrogenation of Oil

IL H DESIGN FOR KRYPTON-85 ENRICHMENT BY THERMAL DIFFUSION

OVERVIEW OF THE TRITIUM-IN-AIR MONITORING SYSTEM OF CERNAVODA NPP U1 ROMANIA MODERNIZATION AND IMPROVEMENT PROJECT

ABB MEASUREMENT & ANALYTICS DATA SHEET. PGC5000 Temperature programmed gas chromatograph

Water Desorption from Metallic Surfaces at Room Temperature

Jianfei Peng et al. Correspondence to: Jianfei Peng Min Hu and Renyi Zhang

Monitoring Flammable Vapors and Gases in Industrial Processes

Deionized Water. Latest technology, highest quality, environmentally friendly. Water Technologies

Cryogenic Instrumentation I Thermometry OUTLINE Thermometry Pt (pure metal) Temperature Ranges of Thermometer Application Typical Resistive Thermal

Experience with Tritium Evolution During Irradiation of MSRE Flibe in the MITR

A New Hyperspectral Spherical-Cavity Absorption Meter

ESTIMATION OF RADIONUCLIDE RELEASES IN ATMOSPHERE FROM CERNAVODA NPP BASED ON CONTINUOUS GASEOUS EFFLUENT MONITORING

Module 2. Measurement Systems. Version 2 EE IIT, Kharagpur 1

ASTM D 6540 Standard Test Method for Accelerated Soiling of Pile Yarn Floor Covering

CROSS FLOW COOLING TOWER

Unit 2. Instrumentation. Experts Teaching from Practical Experience

Traceability research activities in the field of airborne particle number/ mass concentration measurement Liu Junjie, Zhang Wenge, Song Xiaoping

2 April 2004 Copenhagen, Denmark

Keywords: Spiral plate heat exchanger, Heat transfer, Nusselt number

Real-Time Detection: From Gisclard et al.: A Simple Device for Air Analysis. AIHA Quarterly, 14(1):23-25 (1953)

Introduction. Principle of Operation

Modern Physics Laboratory Beta Spectroscopy Experiment

REALIZATION OF HUMIDITY STANDARD FACILITY USING TWO-PRESSURE HUMIDITY GENERATOR AND HUMIDITY CHAMBER

Model 3024 Albedometer. User s Manual 1165 NATIONAL DRIVE SACRAMENTO, CALIFORNIA WWW. ALLWEATHERINC. COM

Explaining Periodic Trends

Differential Mobility Particle Sizer (Aerosol measurements)

ELECTROCHEMICAL TECHNIQUES, OSMOMETRY AND THE PRINCIPLES OF RADIOACTIVITY

PMF2000 Series DESCRIPTION FEATURES APPLICATIONS MAXIMUM RATINGS MASS AIR FLOW SENSOR

Chapter 3 Electrochemical methods of Analysis-Potentiometry

Jeancarlo Torres, CHP. Naval Surface Warfare Center Carderock Division

Verification of intermediate nuclear fusions without harmful radiation and the production of magnecular clusters

Performance Characterization of A New Cam System M.J. Koskelo 1, J.C. Rodgers 2, D.C. Nelson 2, A.R. McFarland 3 and C.A. Ortiz 3

Measurement of Tritium in Helium

EQUIPMENT Beta spectrometer, vacuum pump, Cs-137 source, Geiger-Muller (G-M) tube, scalar

Cryogenic and Electrical Test Results of a 30 M HTS Power Cable

C80. Calvet Calorimeter From ambient to 300 C. A trademark of KEP Technologies group

INTRODUCTION Strained Silicon Monochromator Magnesium Housing Windows for Monochromator Shutter and Collimator Fission Detector HOPG Monochromator

TITLE: Air Kerma Primary Standard: Experimental and Simulation Studies on Cs-137

Cryogenic Target Handling System Operations Manual Volume IV CTHS Description Chapter 5: Tritium Fill Station (TFS)

Academic and Research Staff. Prof. G. A. Brown Prof. J. L. Kerrebrock Prof. J. E. McCune Prof. E. S. Pierson Prof. M. A. Hoffman Prof. C. C.

Rivelazione di neutrini solari - Borexino Lino Miramonti 6 Giugno 2006 Gran Sasso

Gaseous CEMS technology

CRYOGENIC CONDUCTION COOLING TEST OF REMOVABLE PANEL MOCK-UP FOR ITER CRYOSTAT THERMAL SHIELD

Particle Size of Radioactive Aerosols Generated During Machine Operation in High-energy Proton Accelerators

RANGE OF ALPHAS. Advanced Laboratory, Physics 407 University of Wisconsin Madison, Wisconsin 53706

Product data sheet Palas Nanoparticle measurement system DEMC 2000

Validation of. Tetrahydrofuran Using. SKC Passive Sampler Cat. No

Development of Continuous Inflow Tritium in Water Measurement Technology by using Electrolysis and Plastic Scintillator

Acronyms, Abbreviations, and Symbols Foreword to the First Edition Foreword to the Second Edition Preface to the First Edition Preface to the Second

Clean Corona Ionization Technology. Peter Gefter Simco-Ion phone: (1)

Environmental Monitoring Presented on behalf Lutz Moritz (TRIUMF) by

OXEA - Online Elemental Analyzer

HPLC-MS of the Initial Perfluorinated Surfactants and Shorter Chains:

Physics 3211: Electromagnetic Theory (Tutorial)

Transcription:

New Test Results For Physical Separation Of Tritium From Noble Gases And It s Implications For Sensitivity And Accuracy In Air And Stack Monitoring -Robert Goldstein, Ivan Mitev, Dell Williamson, Overhoff Technology Corp

WE FACE A CHALLENGE At many nuclear facilities, Air and Stack monitors have the responsibility to measure: Multiple radio-active materials Separately and simultaneously With great accuracy and high sensitivity EVEN WHEN High concentrations of one material are likely to mask the signals from the low concentration of other materials being measured. WE NOTE THAT Most ionizing radiation detector types exhibit significant cross talk when presented with multiple sources of ionizing radiation. OVERHOFF S RESPONSE Overhoff Technology sees a need for a new family of air and stack monitors

Overhoff Technology sees a need for a family of air and stack monitors to simultaneously measure Tritium Organic C-14 Inorganic C-14 ( 14 CO 2 ) Noble Gases Specifically New -Tritium Carbon-14 Survey Meter New -Tritium Carbon-14 Noble Gas Stack Monitor Upgraded -Tritium Carbon-14 Air Sampler

NEW SURVEY METER Good Results thru Physical Separation TriCair A, B, TriCair-Select Tritium C-14 SURVEY METER

Good Results thru Physical Separation NEW FAMILY OF STACK MONITORS NEWLY UP-GRADED AIR SAMPLERS Triathalon Tritium, C-14, Noble Gas STACK MONITORS TASC Tritium, C-14 SAMPLER With Mass Flow Meter More efficient Re-Combiner

Separation of Tritium Oxide from Noble Gases Via Nafion Membrane TEST PROCEDURE VALIDATION TEST OF A DISCRIMINATING TRITIUM MONITOR FOR MEASURING TRITIUM OXIDE IN THE PRESENCE OF NOBLE GASES

REV. 1 August 25, 2011 APPLICABLE TO: MODELS 421-HTO AND 93-DR-T-HTO OVERHOFF TECHNOLOGY CORPORATION 1160 US ROUTE 50, MILFORD, OHIO, USA

Background Model 421-HTO The Model 421-HTO is designed to measure Tritium concentration in the oxide form (HTO). The collected sample is processed in order that only tritium is measured from a sample which may contain noble gases.

Model 421-HTO Uses An Dual Ionization Chamber Detector.

The measurement side chamber, has sample flowing through it and the other chamber the compensation chamber is sealed. Both chambers are approximately equal in effective volume and respond to external gamma radiation equally. The two chambers have bias voltages of opposite polarity, thus cancelling the effects from background gamma radiation.

Dual chambers share the same axis and are mounted to a common electrometer. Model 421-HTO is designed for a low level detection limit of 0.005 MBq/m3 requiring large chambers with nominal volume of 8 liters each.

Nafion Tube Dryer Efficiency Efficiency of a Nafion tube dryer was tested over the temperature range 5 C to 40 C. ~~~~~~~~~~~~~~~~~~~~~~~ The technique of using a semi permeable membrane in this case a Nafion tube dryer for the separation of tritium in oxide form (HTO) from noble gases in an air sample has been known for over 30 years.

Dryer Process HTO is stripped out of the wet sample that flows through the dryer. The purge gas is combined with the sample of HTO only and is measured in the detector of the monitor. ~~~~~~~~~~~~~~~~~~~~~~~~ This protocol dictates the importance of knowing the efficiency for a given Nafion tube dryer with the operating conditions for these particular monitors.

Use of permeation (Nafion) tube dryer to REMOVE the Noble Gases from the Sample Flow Stream The dryer consists of two concentric flow tubes The outer tube is stainless steel the shell of the inner tube is the permeation membrane Sample gases flow in thru the center tube Clean dry air flows in opposite direction thru the outer tube Any H 2 O or T 2 O moves thru the membrane into the purge flow The Noble Gas goes straight to exhaust or to separate detector The clean purge air carries only Tritium into the Ion Chamber. Purge flow rate 2X main flow rate, results in a Tritium sample concentration 0.5 times the original sample The corrected value is shown on the display

Set-up for Testing Efficiency of a Nafion Tube Dryer

Set-up for Calibrated Injection of Tritium into Test Apparatus

Set-up for Test 2 pumps, the inlet RH sensors, the outlet dew point sensor with sampling cell at the right end of the PVC chamber Purge Flow In Main Flow In

Flow Diagram Two Instruments used together as a test

Nafion Tube Dryer Test Results

Efficiency change with Temperature: 90% at 40 o C to 99% at 5 o C.

Relative Humidity of Exit Gas vs Temperature: 1.5% at 5 o C to 4.3% at 35 o C

Preparation of Clean Dry Purge Gas

Results and Conclusions RESULTS: This test provides data on how efficiency varies over the temperature range 5 C to 40 C. The test was conducted at Overhoff Technology Corporation during July 2011. TEST CONCLUSIONS: The drying efficiency ranged from a minimum of 90% at 40 o C to a maximum of 99% at 5 o C. BATTERY OF TESTS CONCLUSIONS: Detection Limit 0.005 MBq/m3 achieved even in presence of high Nobel Gas Levels

NEW SURVEY METER Good Results thru Physical Separation TriCair A, B, TriCair-Select Tritium Carbon-14 SURVEY METER

Thank you for your attention, Your Questions, Comments and Discussion are very welcome Robert Goldstein, Ivan Mitev, Dell Williamson, Overhoff Technology Corp