Basic and Application Inductively coupled plasma mass spectrometry (ICPMS)

Similar documents
Thermo Scientific icap RQ ICP-MS: Typical limits of detection

Thermo Scientific icap TQ ICP-MS: Typical limits of detection

Determination of ultratrace elements in photoresist solvents using the Thermo Scientific icap TQs ICP-MS

Handling Interferences in the Modern Laboratory with Advanced Triple Quadrupole ICP-MS Technology

Accurate measurement of elemental impurities in metals and metal alloys using the Thermo Scientific icap TQ ICP-MS

Analytical Approaches to Arsenic

Fergus Keenan Shona McSheehy Julian Wills

Analysis of high matrix samples using argon gas dilution with the Thermo Scientific icap RQ ICP-MS

Simplified workflows for the Thermo Scientific icap TQ ICP-MS

Outsmart Interferences with Triple Quadrupole ICP-MS. The world leader in serving science

Determination of Impurities in Silica Wafers with the NexION 300S/350S ICP-MS

Total elemental analysis of food samples for routine and research laboratories using the Thermo Scientific icap RQ ICP-MS

Enhancing the productivity of food sample analysis with the Agilent 7700x ICP-MS

Total Elemental Analysis of Food Samples for Routine and Research Laboratories, using the Thermo Scientific icap RQ ICP-MS

Comparing Collision/Reaction Cell Modes for the Measurement of Interfered Analytes in Complex Matrices using the Agilent 7700 Series ICP-MS

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

Analysis of Trace Metal Impurities in High Purity Hydrochloric Acid Using ICP-QQQ

icap TQ ICP-MS Applications Compendium

Applications of ICP-MS for Trace Elemental Analysis in the Hydrocarbon Processing Industry

Direct Measurement of Metallic Impurities in 20% Ammonium Hydroxide by 7700s/7900 ICP-MS

Determination of challenging elements in ultrapure semiconductor grade sulfuric acid by Triple Quadrupole ICP-MS

Determination of trace elements in ultrapure semiconductor grade sulfuric acid using the Agilent 8900 ICP-QQQ in MS/MS mode

Trace elemental analysis solutions for your application. June 6, 2018

Simple, reliable analysis of high matrix samples according to US EPA Method 6020A using the Agilent 7700x/7800 ICP-MS

Agilent ICP-MS. Fundamentals of ICP-MS Analysis and Its Applications for Low Level Elemental Determination in Cannabis

Determination of Chromium in Gelatin Capsules using an Agilent 7700x ICP-MS

Thermo Scientific ICP-MS solutions for the semiconductor industry. Maximize wafer yields with ultralow elemental detection in chemicals and materials

Trace elemental analysis of distilled alcoholic beverages using the Agilent 7700x ICP-MS with octopole collision/ reaction cell

Rapid Analysis of High-Matrix Environmental Samples Using the Agilent 7500cx ICP-MS. Application. Author. Abstract. Introduction.

The Agilent 7700x ICP-MS Advantage for Drinking Water Analysis

IMPROVING DATA QUALITY WITH ADVANCED INSTRUMENTATION UTILIZING MULTIPLE INTERFERENCE REDUCTION TECHNOLOGIES

Direct Analysis of Trace Metal Impurities in High Purity Nitric Acid Using ICP-QQQ

Agilent s New 8800 ICP-QQQ. Transforming ICP-MS Technology

Implementing EPA Method 6020 with the Agilent ICP-MS Portfolio

Advanced ICP-MS techniques for overcoming interferences in LA-ICP-MS bioimaging

Fundamentals of the ICP-MS Technique and How to Resolve Issues for Pharmaceutical Materials (In 20 Minutes) Tim Shelbourn, Eli Lilly and Company

Agilent 8900 Triple Quadrupole ICP-MS

Application note. Trace level analysis of sulfur, phosphorus, silicon and chlorine in NMP using the Agilent 8800 Triple Quadrupole ICP-MS

The ultratrace determination of iodine 129 in aqueous samples using the 7700x ICP-MS with oxygen reaction mode

INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY

Analysis of noble metals at low levels in geological reference materials and ores

Trace Analyses in Metal Matrices Using the ELAN DRC II

Robust ICP-MS with ease of use and high productivity for routine laboratories

Key Analytical Issues: Sample Preparation, Interferences and Variability. Tim Shelbourn, Eli Lilly and Company

Multi-Element Analysis of Cannabis using the Agilent 7800 ICP-MS

Semiquantitative Screening of Pharmaceutical Antiviral Drugs using the Agilent 7500ce ICP-MS in Helium Collision Mode

Rapid, simple, interference-free analysis of environmental samples using the XSERIES 2 ICP-MS with 3 rd generation CCT ED

Techniques for the Analysis of Organic Chemicals by Inductively Coupled Plasma Mass Spectrometry (ICP-MS)

Partial Energy Level Diagrams

Ultra trace measurement of potassium and other elements in ultrapure water using the Agilent 8800 ICP-QQQ in cool plasma reaction cell mode

Lead isotope analysis: Removal of 204 Hg isobaric interference from 204 Pb using ICP-QQQ in MS/MS mode

Accurate Analysis of Trace Mercury in Cosmetics using the Agilent 8900 ICP-QQQ

Redefining triple quadrupole technology with unique ease of use

Agilent Technologies at TIAFT 2013

Multi-Element Analysis of Petroleum Crude Oils using an Agilent 7900 ICP-MS

Accurate analysis of neptunium 237 in a uranium matrix, using ICP-QQQ with MS/MS

Atomic Spectroscopy AA/ICP/ICPMS:

Hands on mass spectrometry: ICP-MS analysis of enriched 82 Se samples for the LUCIFER experiment

Sample Analysis Design PART II

Determination of Trace Metals in Human Urine Using the NexION 300 ICP-MS

PRINCIPLE OF ICP- AES

Low Level Detection of Priority Inorganic Pollutants in Water. Anthony Neumann, MSc Darren Crichton, BSc

Sample Analysis Design Polyatomic Interferences

High Throughput Water Analysis using Agilent 7900 ICP-MS coupled with ESI prepfast

Today s Agilent Solutions for Determining Heavy Metals in Food using Atomic Spectroscopy

atomic absorption spectroscopy general can be portable and used in-situ preserves sample simpler and less expensive

DISCLAIMER: This method:

Sample Analysis Design PART III

The New Agilent 7700 Series ICP-MS

Direct Analysis of Photoresist Using Inductively Coupled Plasma Mass Spectrometry (ICP-MS) Application

Authors: C. Derrick Quarles, Jr. *, Patrick Sullivan, M. Paul Field, Hwan Kim, and Daniel R. Wiederin

Real World Analysis of Trace Metals in Drinking Water Using the Agilent 7500ce ICP-MS with Enhanced ORS Technology. Application. Authors.

Agilent s Solutions for Nanoparticles Analysis ICP-MS, ICP-MS/MS, software. Alain Desprez Agilent Technologies

Recent Advances in Trace Elemental Analysis

high temp ( K) Chapter 20: Atomic Spectroscopy

Florida State University Libraries

The 30-Minute Guide to ICP-MS

Elemental analysis of river sediment using the Agilent 4200 MP-AES

Key Words Nanoparticles, spicp-ms, ICP-MS, Qtegra ISDS Software, AF4-ICP-MS

Inductively Coupled Plasma Mass Spectrometry (ICP-MS) Debjani Banerjee Department of Chemical Engineering IIT Kanpur

Ultra-fast determination of base metals in geochemical samples using the 5100 SVDV ICP-OES

Direct Measurement of Trace Metals in Edible Oils by 7500cx ICP-MS with Octopole Reaction System

Advances in Interference Removal for Accurate Arsenic Analysis in Food and Beverages

Determination of Nanoparticle Sizeand Number Concentration using the npquant Evaluation Module for Qtegra ISDS. The world leader in serving science

ICP/MS Multi-Element Standards

Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS)

Analysis of Arsenic, Selenium and Antimony in Seawater by Continuous-Flow Hydride ICP-MS with ISIS

Rapid and precise calcium isotope ratio determinations using the Apex-ACM desolvating inlet system with sector-field ICP-MS in low resolution

TOXICOLOGY & FORENSIC APPLICATIONS

ICP-OES Application Note Number 35

Simple and Reliable Soil Analysis using the Agilent 7800 ICP-MS with ISIS 3

Agilent 8800 Triple Quadrupole ICP-MS: Understanding oxygen reaction mode in ICP-MS/MS

Rapid Detection of Americium-241 in Food by Inductively-Coupled Plasma Mass Spectrometry

Following documents shall be used for reference on quantities, units, prefixes and other technical vocabulary in this document:

Overcoming Interferences with the Thermo Scientific icap 7000 Plus Series ICP-OES

Sources of Errors in Trace Element and Speciation Analysis

Samples compliant with the WATER

Quantitative chemistry Atomic structure Periodicity

Opening the analytical black box: Insights into interferences, corrections, and data quality

Lecture 7: Atomic Spectroscopy

Transcription:

Basic and Application Inductively coupled plasma mass spectrometry (ICPMS)

2 What is ICP MS Inductively coupled plasma mass spectrometry (ICP-MS) is a type of mass spectrometry which is capable of detecting metals and several non-metals at concentrations as low as one part in 10 12 (ppt). This is achieved by ionizing the sample with inductively coupled plasma and then using a mass spectrometer to separate and quantify those ions. Mission : Convert all analyses species in sample to each isotope ions which be able to measure by mass spectrometer. Examples : if we are looking for Calcium in water sample. Ca + (CaCl 2 ) xh 2 O (CaCO 3 ) xh 2 O (CaSO 4 ) xh 2 O (CaF 2 ) xh 2 O

3 ICP-MS M ++ MS need an singly charged ions Atom M Ions M + 2 nd ionization M +* Emission line 2 h 1 st ionization M* M. + h Emission HCL atomization AAs Gas MX Solid vaporization Solution droplet (MX) n desolvation M(H2O) m+, X -

4 <1x10-5 torr ICP-MS Instrumental Ion Source Mass Analyzer Detector Torch Spray chamber Nebulizer Ion source + + = Atmospheric pressure

<1x10-5 torr ICP-MS Instrumental Ion Source Mass Analyzer Detector How to extract the ions into MS? The positively charged ions that are produced in the plasma are extracted into the vacuum system, via a pair of interface cones and the extraction lens Sample cone Extraction lens Skimmer cone Interface Atmospheric pressure Vacuum region Interface region 5

6 <1x10-5 torr ICP-MS Instrumental Ion Source Mass Analyzer Detector The Right Angular Positive Ion Deflection (RAPID) lens The open lens stack eliminates lens cleaning maintenance and a completely off-axis design together with QCell technology delivers a class leading background noise. Ion, Neutral, Photons Neutral, Photons Elimination of neutral species Atmospheric pressure

7 Polyatomic interference 40 Ar 16 O 40 Ca 16 O 40 Ar 35 Cl

8 <1x10-5 torr How to remove Polyatomic Interference? He KED mode Ion Source Mass Analyzer Detector Qcell Collision/Reaction Cell (CRC) Flatapole technology for improved transmission Low mass cut off filters out unwanted precursor ions Single mode interference removal with He He KED filters out unwanted polyatomic interferences Small CRC volume for fast gas exchange Flexibility to work with reactive gases, such as mixtures of O 2 7% dilute H 2 or 1% NH 3 Non-consumable, zero-maintenance Atmospheric pressure

How to remove Polyatomic Interference? He KED mode He KED filters out unwanted polyatomic interferences High transmission enables analysis of even low mass analytes in He KED mode Single measurement mode for all analytes in analytical method Target analyte 75 As + Quadrupole set to filter out exact mass of target analyte e.g. 75As+ Comprehensive Interference Removal Quadrupole isolates ions wanted for measurement 9 No gas switching makes method more productive and simple No change of measurement mode effectively eliminates method development Unique Flatapole Design 75 As+ 40Ar35Cl + Ca(OH) 2 H + ArCl + Ca(OH) 2 H + Complex matrix He KED filters out unwanted polyatomic interferences, based on difference in cross-sectional size of the analyte and polyatomic

10 Decreasing Energy How to remove polyatomic interference? He KED mode Collisional retardation / energy filtering Quadrupole Cell Pre-Cell From plasma To detector Collision/Reaction gas atom or molecule Energy Barrier Simple, effective interference removal Analyte Ion M + - Small collision crosssection Polyatomic Species e.g. ArX + Larger collision cross-section

11 Simplicity and Productivity Low mass cut-off QCell flatapole dynamically applies Low Mass Cut Off (LCMO) relative to target analyte Anal LMCO Interferences Precursors 51 V 35 35 Cl 16 O, 37 Cl 14 N, 34 S 16 OH H, N, O, S, Cl 56 Fe 39 40 Ar 16 O, 40 Ca 16 O O, Ar, Ca Target analyte 75 As + Quadrupole set to filter out exact mass of target analyte e.g. 75As+ Comprehensive Interference Removal Quadrupole isolates ions wanted for measurement 63 Cu 45 40 Ar 23 Na, 12 C 16 O 35 Cl, 31 P 32 S C, N, O, Na, P, S, Cl, Ar 75 As 47 40 Ar 35 Cl, 40 Ca 35 Cl, 40 Ar 34 SH, 37 Cl 2 H Unique Flatapole Design H, S, Cl, Ca, Ar Comple x matrix Low mass cut off filters out unwanted precursor ions; ions are then unable to recombine later in the QCell and backgrounds are reduced further than KED alone

12 Simplicity and Productivity Low mass cut-off QCell flatapole dynamically applies Low Mass Cut Off (LCMO) relative to target analyte Anal LMCO Interferences Precursors 51 V 35 35 Cl 16 O, 37 Cl 14 N, 34 S 16 OH H, N, O, S, Cl 56 Fe 39 40 Ar 16 O, 40 Ca 16 O O, Ar, Ca Target analyte 75 As + Quadrupole set to filter out exact mass of target analyte e.g. 75As+ Comprehensive Interference Removal Quadrupole isolates ions wanted for measurement 63 Cu 45 40 Ar 23 Na, 12 C 16 O 35 Cl, 31 P 32 S 75 As 47 40 Ar 35 Cl, 40 Ca 35 Cl, 40 Ar 34 SH, 37 Cl 2 H Unique Flatapole Design C, N, O, Na, P, S, Cl, Ar H, S, Cl, Ca, Ar All unwanted precursors that contribute to intereferences are eliminated 40 Ar +, 40 Ca +, 35 Cl +, 16 O +, 1 H + Low mass cut off filters out unwanted precursor ions; ions are then unable to recombine later in the QCell and backgrounds are reduced further than KED alone Comple x matrix

13 Superior Interference Suppression Calibration curve for 75 As in a solution containing 0.5% HCl STD mode: Polyatomic interference leads to poor IDL and elevated BEC KED mode: Polyatomic interference removed IDL below 5 ppt

14 STD (no gas), KED and CCT mode 7 Li ~1,000 cps 35 Cl 16 O ~110,000 cps 59 Co ~65,000 cps 115 In ~230,000 cps 140 Ce ~260,000 cps 238 U ~690,000 cps 7 Li ~50 cps 35 Cl 16 O ~100 cps 59 Co ~25,000 cps 115 In ~30,000 cps 140 Ce ~90,000 cps 238 U ~270,000 cps 7 Li ~11,000 cps 35 Cl 16 O ~1,300,000 cps 59 Co ~120,000 cps 115 In ~260,000 cps 140 Ce ~260,000 cps 238 U ~370,000 cps

15 What s the difference between a SQ and TQ-ICP-MS icap RQ ICP-MS icap TQ ICP-MS Additional Q1 mass filter quadrupole Additional electronics Additional gases Enhanced software Same platform there are more differences than you think!

16 Thermo Scientific TQ ICP-MS How it Works 91 [AsO] + 59 Co 16 O +, 150 Sm ++ Q3 set to product ion mass (m/z 91) Q3 isolates the product ion of the analyte and removes any remaining interferences through a second stage of mass filtration Q2 filled with reactive gas (O 2 ) 75 As + 91 [AsO] + Optimal reaction conditions in Q2 are achieved through the selection of the appropriate measurement mode in Reaction Finder Q1 set to analyte mass (m/z 75) 59 Co +, 91 Zr + Q1 rejects unwanted ions and preselects the analyte. This first stage of mass filtration rejects precursors and ions with the same m/z ratio as the product ion. 75 As +

17 Find out what is going on inside the TQ ICP-MS

18 Thermo Scientific icap TQ ICP-MS Problem Feature Benefit Value Interference removal still major challenge in ICP- MS TQ technology dramatically improves interference removal Measure more accurately and with lower LOD Meet requirements of challenging applications Analyte Interference Interference M + Analyte with Interference M + Mass Shift (M+16) +

19 Interference removal using TQ Reaction Chemistry (with O 2 ) Precursor Ion Analyte Isobaric Interference Mass Shift Interference (M 16) + M + (M + 16) + Mixture of analytes and interferences

20 Interference removal using TQ Reaction Chemistry (with O 2 ) Precursor Ion Analyte Isobaric Interference Mass Shift Interference Q1 (M 16) + M + (M + 16) + Mixture of analytes and interferences Filters Pre-Cursor Ions and Mass Shift Interference (M 16) + M + (M + 16) +

21 Interference removal using TQ Reaction Chemistry (with O 2 ) Precursor Ion Analyte Isobaric Interference Mass Shift Interference Interference free Q1 CRC TQ-O 2 Mass Shift (M 16) + M + (M + 16) + (M 16) + M + (M + 16) + Mixture of analytes and interferences Filters Pre-Cursor Ions and Mass Shift Interference (M 16) + M + (M + 16) +

22 Interference removal using TQ Reaction Chemistry (with O 2 ) Precursor Ion Analyte Isobaric Interference Mass Shift Interference Interference free CRC TQ-O 2 TQ Mass Shift Q1 mode Mass is typically Shift used with: (M 16) + Oxygen, Ammonia, Hydrogen M + (M + 16) + It is used for analytes which preferentially react with the reactive gas (M 16) + M + (M + 16) + Mixture of analytes and interferences Filters Pre-Cursor Ions and Mass Shift Interference (M 16) + M + (M + 16) +

23 Interference removal using TQ Reaction Chemistry (with O 2 ) Precursor Ion Analyte Isobaric Interference Mass Shift Interference Q1 (M 16) + M + (M + 16) + (M 16) + M + (M + 16) + Interference free Mixture of analytes and interferences Filters Pre-Cursor Ions and Mass Shift Interference CRC TQ-O 2 On Mass (M 16) + M + (M + 16) +

24 Interference removal using TQ Reaction Chemistry (with O 2 ) Precursor Ion Analyte Isobaric Interference Mass Shift Interference Q1 TQ On Mass mode is typically used with: Oxygen, Hydrogen Interference free (M 16) It + is M + used (M + for 16) + analytes where (M the 16) + interference M + (M + 16) + preferentially reacts Mixture of analytes and Filters Pre-Cursor Ions and interferences Mass Shift Interference with the reactive gas CRC TQ-O 2 On Mass (M 16) + M + (M + 16) +

25 Applications we are going to focus on... Environmental Analysis As, Se Clinical Research - Ti Advanced Applications Metallurgy Speciation Analysis Laser Ablation - Imaging

App Note : Ultratrace elements in Semiconductor grade IPA using ICPMS Isopropyl alcohol (IPA) is used to solvent clean wafers during production in the semiconductor industry IPA has been considered a difficult matrix to analyze directly by ICP-MS high volatility low viscosity high carbon content Kinetic energy discrimination (KED) can remove carbon based interferences from the sample matrix and argon based interferences from the ICP 26

27 Instrument configuration and Sample preparation Standard concentration : 20, 50, 100 and 200 ng/l IPA sample was spiked with 100 ng/l Measurement of 26 elements at ultratrace concentrations in IPA was achieved in less than 5 minutes. (sample uptake, analysis and washout as well as the switching time between hot and cold plasma within each measurement) Low ionization potential (IP) elements : Li, Na, Mg, K, Ca, Al as well as first row transition metals; Cr, Fe are measured with low backgrounds and high sensitivities in cold plasma Higher IP elements are analyzed in hot plasma

28 Calibration Curve Mg m/z 24 - Mg at m/z 24 in IPA under hot plasma conditions is complicated by a carbon dimer species (12C 2 ) - Cold plasma can remove interference at m/z 24 and provide the sub ng/l detection limit (LOD) and background equivalent concentration (BEC)

29 BEC, LOD and recovery data for the analysis of semiconductor grade IPA Fast, reliable, in measurement switching between hot and cold plasma even for volatile organic solvents

Biological Function [%] Deficient Optimum Range Toxic Arsenic: A potential hazard in the food chain Inorganic As [As (III), (V)] App Note 43285 : As and Se in environmental samples The role of As and Se in the environment Selenium: An essential nutrient Arsenosugars and - lipds As Organic Arsenic [ArsenobetaineDM A etc.] Concentration in diet Many different chemical forms (species) are known that strongly differ in toxicity and bioavailability Plants such as rice are well known for high accumulation of As from soils Knowledge of Se content in soil may prevent Se deficiency in both human and animal populations

Sample preparation Calibration standards of arsenic and selenium : Concentrations of 0.2, 0.5, 1, 2 and 5 µg/l 1 ppm of Dy, Gd, Nd, Sm and Tb added 35 mg of a marine sediment sample, collected from the deep Pacific Ocean + 50 mg of the andesite reference standard AGV-1 and treated in closed PTFE vessels with concentrated HNO 3 overnight to oxidize any organic matter (if present). Concentrated HF (1.5 ml) and HClO 4 (1.5 ml) added Heated in a hot block for 12 h at 180 C. After digestion, the acids were evaporated on a hot plate at 180 C to near dryness. The residues were re-dissolved, fumed off three times with 6N HCl to near dryness and finally taken up in 10 ml 1N HNO 3 Prior to analysis, both samples were further 1:10 diluted with 1% HNO 3 /2% MeOH Lutetium was added at a concentration of 1 µg L-1 as an internal standard The use of methanol is important in the analysis of arsenic and selenium due to the effect of carbon enhancement in the plasma which increases the ionization of both elements. 31

As and Se with REE present - Different modes For different measurement modes were evaluated: SQ-STD - Single quadrupole mode with no collision/reaction cell (CRC) gas. SQ-H 2 - Single quadrupole mode with CRC pressurized with pure hydrogen as reaction gas SQ-KED - Single quadrupole mode with CRC pressurized with helium as a collision gas and KED applied. TQ-O 2 Triple quadrupole mode with CRC pressurized with oxygen as a reaction gas, Q1 set to analyte mass (M+) and Q3 set to product ion mass (MO+) 32

33 TQ mode - As and Se in environmental samples Interferences on As and Se: Ar 2, ArCl easy to remove using He KED but if REE are present... Single Quad ICP-MS: KED Typically enhances M 2+ Interferences Doubly charged ions (e.g. 156 Gd ++ ) appear at m/z 78 and hence interfere with the detection of 78 Se + As and Se, m/z 75, 78, 80 Rare Earth Elements, m/z 140-176 150 Sm, 156 Gd, 160 Gd m/z

34 TQ mode - As and Se in environmental samples Interferences on As and Se: Ar 2, ArCl easy to remove using He KED but if REE are present... Single Quad ICP-MS: KED Typically enhances M 2+ Interferences Solution: Mass shift As and Se using O 2 Doubly charged ions (e.g. 156 Gd ++ ) appear at m/z 78 and hence interfere with the detection of 78 Se + As and Se, m/z 75, 78, 80 75 As 16 O +, 78 Se 16 O +, 80 Se 16 O + @ m/z 91, 94 and 96 m/z Rare Earth Elements, m/z 140-176 150 Sm, 156 Gd, 160 Gd

Solution use the TQ Mass shift reactions that move the analyte of interest to a different m/z Control ions entering the cell using Q1 Use O 2 to efficiently convert As and Se to AsO and SeO in Q2 the REE ++ don t react Selectively detect AsO and SeO free from REE ++ interference, using Q3 Type Polyatomic 75 As Method to remove 40 Ar 35 Cl KED 40 Ca 35 Cl Isobaric 150 Nd ++ O 2 150 Sm ++ Type 78 Se Method to remove Polyatomic 40 Ar 38 Ar KED, H 2 Isobaric 156 Gd ++ O 2 156 Dy ++ 35

36 As and Se with REE present - results in different modes Interference removal capability Increased BECs observed for all SQ-modes due to unresolved doubly charged REE interferences Hydrogen is suitable for removing Ar based polyatomics, but is not capable of fully removing REE 2+ interferences TQ-O 2 mode shows dramatically lower BEC values for both As and Se

Proving the accuracy of the sample analysis Sample analysis results Spike recovery in REE matrix solution (1 ppb As and Se) Spike recovery results in samples (1 ppb As and Se) Analyte AGV-1 Sediment Arsenic 94.6 % 97.6 % Selenium 93.4 % 97.6 % 37

38 TN 43283 Total elemental analysis in clinical research using TQ Focus on the development of a robust method for the analysis of titanium and other trace elements in human serum reference materials using TQ ICP-MS.

39 TN 43283 Total elemental analysis in clinical research using TQ Sample preparation Certified reference materials (Seronorm Trace Elements in Serum L- 1 and L-2 and volunteered human urine Sample were diluted 10 fold in 0.5% nitric acid and 2% tetramethylammotnium hydroxide (TMAH) and ultra-pure water Calibration blank, a series of standards and a Quality Control (QC) were prepared using the same procedure All samples and standards were spiked with an internal standard mix (10 µg/l Ge, Y, Rh, Te and Bi)

40 Recovery of Ti in Serum using Different Modes Single Quadrupole ICP-MS Triple Quadrupole ICP-MS

Recovery of Ti in Serum using Different Modes Single Quadrupole ICP-MS Triple Quadrupole ICP-MS False positive results due to unresolved isobaric 48 Cd Interference! Only by using triple quad technology can accurate results for Ti be obtained! Excellent agreement with certified value obtained for Ti Attainable detection sensitivity allowed to detect low concentrations of Ti in the prepared sample solution 41

42 Recovery of Ti in Serum using Different Modes Single Quadrupole ICP-MS Triple Quadrupole ICP-MS False positive results due to unresolved isobaric 48 Ca Interference! Only by using triple quad technology can accurate results for Ti be obtained! Background signal on 48 Ti 14 N 4 H 10 for a solution containing 10 mg L -1 of Cd This would be a problem using single quadrupole instruments with NH 3!

43 Results Multi-elemental analysis in urine and serum Excellent agreement to certified/reported values was achieved for all elements Full multi-elemental analysis run together with dedicated interference removal for difficult analytes in one Use as a good example of TQ multi-element data

Speciation in Qtegra ISDS Software Hardware: IC and LC IC is entirely metal free and thus ideally suited Control over hardware: Chromeleon plug-in for Qtegra Data evaluation: tquant Compound specific calibration Peak integration algorithms 44 AN43255 Determination of Inorganic Arsenic in Rice using IC-ICP-MS AN43099 IC-ICP-MS speciation analysis of As in apple juice using the Thermo Scientific icap Q ICP-MS AN43141 Total and speciation analysis of Mercury in contact lens solutions by ICP-MS AN43227 Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry AN43098 Speciation Analysis of Cr (III) and Cr (VI) in Drinking Waters Using Anion Exchange Chromatography Coupled to the Thermo Scientific icap Q ICP-MS

45 Nanoparticle Characterization in Qtegra ISDS Software Nanoparticle analysis by sp-icp-ms becoming a part of routine measurements spicp-ms data handling and processing for consistent and accurate interpretation of the data; to give the right result Hardware: High Sensitivity Interface and 100 ul/min nebulizer Software: npquant plug-in Acquire and evaluate data for nanoparticle size characterization Automated determination of key input parameters Statistical evaluation of each data set to judge data quality 20 40 60 nm

46 Laser Ablation in Qtegra ISDS Software Fully automated optimization for LA-ICP-MS The high base sensitivity of the icap RQ enables routine analysis in He KED LA-ICP-MS. Results for Cr and Fe isotopes in LA-ICP-MS analysis of artificial sapphire.

Thank You for Your Attention Get Connected www.scispec.co.th/ Follow Us @scispec https://www.facebook.com/scispec/