Sample Analysis Design PART II

Similar documents
Sample Analysis Design PART III

Sample Analysis Design Polyatomic Interferences

Sample Analysis Design Internal Standard

Analysis of high matrix samples using argon gas dilution with the Thermo Scientific icap RQ ICP-MS

Thermo Scientific icap RQ ICP-MS: Typical limits of detection

Determination of Impurities in Silica Wafers with the NexION 300S/350S ICP-MS

Solutions and Ions. Pure Substances

Sources of Errors in Trace Element and Speciation Analysis

February 20, Joe Cerniglia The International Group for Historic Aircraft Recovery (TIGHAR) Job Number: S0CHG688. Dear Joe:

Radiometric Dating (tap anywhere)

Element Cube Project (x2)

Thermo Scientific icap TQ ICP-MS: Typical limits of detection

Fergus Keenan Shona McSheehy Julian Wills

7. Relax and do well.

Determination of Chromium in Gelatin Capsules using an Agilent 7700x ICP-MS

Comparing Collision/Reaction Cell Modes for the Measurement of Interfered Analytes in Complex Matrices using the Agilent 7700 Series ICP-MS

PERIODIC TABLE OF THE ELEMENTS

JRP SIB09 Elements GOOD PRACTICE GUIDE ON DEALING WITH INTERFERENCES IN ICP-MS FOR INVESTIGATING HIGH PURITY MATERIALS. Deliverable 1.2.

(please print) (1) (18) H IIA IIIA IVA VA VIA VIIA He (2) (13) (14) (15) (16) (17)

Faculty of Natural and Agricultural Sciences Chemistry Department. Semester Test 1. Analytical Chemistry CMY 283. Time: 120 min Marks: 100 Pages: 6

Enhancing the productivity of food sample analysis with the Agilent 7700x ICP-MS

Determination of trace elements in ultrapure semiconductor grade sulfuric acid using the Agilent 8900 ICP-QQQ in MS/MS mode

TRU Chemistry Contest Chemistry 12 May 21, 2003 Time: 90 minutes

Partial Energy Level Diagrams

Trace elemental analysis of distilled alcoholic beverages using the Agilent 7700x ICP-MS with octopole collision/ reaction cell

The Periodic Table. Periodic Properties. Can you explain this graph? Valence Electrons. Valence Electrons. Paramagnetism

Nucleus. Electron Cloud

Samples compliant with the WATER

Lab Day and Time: Instructions. 1. Do not open the exam until you are told to start.

Fundamentals of the ICP-MS Technique and How to Resolve Issues for Pharmaceutical Materials (In 20 Minutes) Tim Shelbourn, Eli Lilly and Company

Rapid Analysis of High-Matrix Environmental Samples Using the Agilent 7500cx ICP-MS. Application. Author. Abstract. Introduction.

Ar Ar + e - INDUCTIVELY+COUPLED+ PLASMA+SPECTROMETRY+ What+is+Plasma?+ FuncDon+of+Plasma+

Analysis of Trace Metal Impurities in High Purity Hydrochloric Acid Using ICP-QQQ

Precise Determination of Trace Elements in Geological Samples by ICP-MS Using Compromise Conditions and Fine Matrix- Matching Strategy

7) Applications of Nuclear Radiation in Science and Technique (1) Analytical applications (Radiometric titration)

Lab Day and Time: Instructions. 1. Do not open the exam until you are told to start. Page # Points possible Points awarded

Lab Day and Time: Instructions. 1. Do not open the exam until you are told to start.

Lab Day and Time: Instructions. 1. Do not open the exam until you are told to start.

Faculty of Natural and Agricultural Sciences Chemistry Department. Semester Test 1 MEMO. Analytical Chemistry CMY 283

7. Relax and do well.

Last 4 Digits of USC ID:

Direct Analysis of Trace Metal Impurities in High Purity Nitric Acid Using ICP-QQQ

Lab Day and Time: Instructions. 1. Do not open the exam until you are told to start.

Agilent 8800 Triple Quadrupole ICP-MS: Understanding oxygen reaction mode in ICP-MS/MS

INSTRUCTIONS: Exam III. November 10, 1999 Lab Section

CHEM 171 EXAMINATION 1. October 9, Dr. Kimberly M. Broekemeier. NAME: Key

Direct Measurement of Metallic Impurities in 20% Ammonium Hydroxide by 7700s/7900 ICP-MS

Chemistry Standard level Paper 1

Key Analytical Issues: Sample Preparation, Interferences and Variability. Tim Shelbourn, Eli Lilly and Company

Guide to the Extended Step-Pyramid Periodic Table

8. Relax and do well.

(C) Pavel Sedach and Prep101 1

1 Genesis 1:1. Chapter 10 Matter. Lesson. Genesis 1:1 In the beginning God created the heavens and the earth. (NKJV)

Determination of challenging elements in ultrapure semiconductor grade sulfuric acid by Triple Quadrupole ICP-MS

NAME: FIRST EXAMINATION

Part 2. Multiple choice (use answer card). 90 pts. total. 3 pts. each.

Chem Exam 1. September 26, Dr. Susan E. Bates. Name 9:00 OR 10:00

8. Relax and do well.

The Agilent 7700x ICP-MS Advantage for Drinking Water Analysis

CHEM 107 (Spring-2004) Exam 2 (100 pts)

INSTRUCTIONS: CHEM Exam I. September 13, 1994 Lab Section

Trace Analyses in Metal Matrices Using the ELAN DRC II

The Periodic Table of Elements

Analytical Methods. Electronic Supplementary Information File

The exam must be written in ink. No calculators of any sort allowed. You have 2 hours to complete the exam. Periodic table 7 0

CHEM 107 (Spring-2005) Exam 3 (100 pts)

ICP/MS Multi-Element Standards

Instructions. 1. Do not open the exam until you are told to start.

If anything confuses you or is not clear, raise your hand and ask!

Chapter 3: Stoichiometry

CHEM 10113, Quiz 5 October 26, 2011

7. Relax and do well.

8. Relax and do well.

HANDOUT SET GENERAL CHEMISTRY II

Instructions. 1. Do not open the exam until you are told to start.

8. Relax and do well.

Opening the analytical black box: Insights into interferences, corrections, and data quality

CLASS TEST GRADE 11. PHYSICAL SCIENCES: CHEMISTRY Test 4: Matter and materials 1

Why all the repeating Why all the repeating Why all the repeating Why all the repeating

OES - Optical Emission Spectrometer 2000

M11/4/CHEMI/SPM/ENG/TZ2/XX CHEMISTRY STANDARD LEVEL PAPER 1. Monday 9 May 2011 (afternoon) 45 minutes INSTRUCTIONS TO CANDIDATES

HANDOUT SET GENERAL CHEMISTRY I

Chemistry 431 Practice Final Exam Fall Hours

8. Relax and do well.

Chemistry Standard level Paper 1

Atoms and the Periodic Table

8. Relax and do well.

CHEM 167 FINAL EXAM MONDAY, MAY 2 9:45 11:45 A.M GILMAN HALL

Multi Analyte Custom Grade Solution. Aluminum, Potassium, Magnesium, ANALYTE CERTIFIED VALUE ANALYTE CERTIFIED VALUE

Chem 51, Spring 2015 Exam 8 (Chp 8) Use your Scantron to answer Questions There is only one answer for each Question. Questions are 2 pt each.

MANY ELECTRON ATOMS Chapter 15

9/20/2017. Elements are Pure Substances that cannot be broken down into simpler substances by chemical change (contain Only One Type of Atom)

Chemistry 2 Exam Roane State Academic Festival. Name (print neatly) School

Current State of Extraction Don t Be Deceived! Sharon F. Webb, Ph.D. Director of Quality Program

7. Relax and do well.

Made the FIRST periodic table

Lecture 7: Atomic Spectroscopy

Chapter 12 The Atom & Periodic Table- part 2

ELEMENTAL ANALYSIS OF GLASS EXAMINATIONS (PART 1) Module 4

CHEM 130 Exp. 8: Molecular Models

Transcription:

Sample Analysis Design PART II

Sample Analysis Design Generating high quality, validated results is the primary goal of elemental abundance determinations It is absolutely critical to plan an ICP-MS analysis carefully from sample gathering to final analysis on the ICPMS Always create and follow an analysis design that shall permit you to follow the procedure for future samples, AND know what you did when looking at old data

Sample Analysis Design Goal: high quality, validated, quantitative determination of elemental concentrations/isotope ratios This goal can be achieved by: Specificity - only detecting isotope(s) of interest, not interferences, OR making sure that matrix effects do not play a role Sensitivity - can we differentiate the isotope of interest from the background signal? Accuracy - does the analysis represent the real value? Precision - how repeatable is the value?

Sample Analysis Design Sensitivity and Precision: generally defined by how well the instrument is tuned (assuming dilution factor is appropriate) Specificity and Accuracy: generally governed by how well you prepare your sample and set up your analysis method/ parameters

Sample Analysis Design Spectroscopic interferences Matrix effects

Sample Analysis Design Interference analytical artifact which causes the ion signal in a sample to vary from an idealized (true) signal Interferences cause inaccurate analyses Two main types: 1. Spectroscopic 2. Nonspectroscopic

Sample Analysis Design Spectroscopic Interferences in ICP-MS 1. Isobaric overlap 2. Polyatomic ions 3. Refractory oxides 4. Doubly charged ions

Sample Analysis Design Isobaric Overlap Two different elements having the same nominal mass E.g., 40 Ca (96.9%) and 40 Ar (99.6%) Monoisotopic elements: B, Na, Al, Sc, Mn, As, Nb, Y, Rh, I, Cs, Pr, Tb, Ho, Tm, Au, Th None have isobaric interferences

Sample Analysis Design Isobaric Overlap A few multi-isotope elements have no interference free isotopes: E.g., In - 113 In 113 Cd, and 115 In 115 Sn Usually possible to choose an interference free isotope or one that is unlikely to be interfered upon strongly (either due to very low natural abundance of interfering element (isotope) or the interfering element (isotope) is not present in sample)

Sample Analysis Design Isobaric Overlap IF an isobaric interference is unavoidable, you can correct for it by measuring the counts on a non-interfering isotope of the interfering element CPS analyte = CPS total -CPS interferent *(X a /X b ) X a = abundance of interfering isotope X b = abundance of non-interfering isotope

Sample Analysis Design Polyatomic Interferences More serious than isobaric interferences Result from possible, short-lived combination of atomic species in the plasma or during ion transfer Common recombinants are Ar, H, and O Dominant elements in reagents also form polyatomic interferences - N, S, and Cl

Sample Analysis Design Polyatomic Interferences Analyzing deionized water with ICP-MS instrument we have solely H and O present (within the matrix ) Thus, peaks would be visible at masses: 41 ( 40 Ar + 1 H) 41 K 56 ( 40 Ar + 16 O) 56 Fe 80 ( 40 Ar + 40 Ar) 80 Se As well as other minor peaks from the minor isotopes of Ar and O

Sample Analysis Design Polyatomic Interferences If you acidify the deionized water with HNO 3 or H 2 O 2, these behave in the same manner as deionized water these acids are considered ideal matrices as they don t add unnecessary polyatomic interferences Acidification with HCl or H 2 SO 4 changes the situation since Cl and S can be used to form polyatomic ions

HCl matrix: Sample Analysis Design Polyatomic Interferences 35 Cl + 16 O = 51 V 37 Cl + 16 O = 53 Cr 40 Ar + 35 Cl = 75 As 40 Ar + 37 Cl = 77 Se

Sample Analysis Design Polyatomic Interferences H 2 SO 4 matrix: 32 S + 16 O = 48 Ti 32 S + 16 O + 16 O, or 32 S + 32 S = 64 Zn, 64 Ni 34 S + 16 O = 50 Ti, 50 V, 50 Cr 33 S + 16 O + 16 O = 65 Cu

Sample Analysis Design These interferences will be present just from the gas and solvent Therefore, if possible, solutions should be prepared with a weak (1-5% v/v) HNO 3 acid matrix Why not deionized water? acid helps keep elements from sticking to sides of test tubes and tubing during transport ionization efficiency is significantly lower relative to HNO 3

Sample Analysis Design Polyatomic Interferences The most serious polyatomic interferences are formed from the most abundant isotopes of H, C, N, O, Cl, and Ar So, if polyatomic interferences are present in plain deionized water with no other ions present, what happens in natural (complex) samples/matrices?

Sample Analysis Design Polyatomic Interferences Need to know the most abundant elements present in sample Is (are) there any one (or more) elements present that are in very high abundances? If so - then it s likely interferences could be formed from such abundant element(s) E.g., rock samples - high Si

Sample Analysis Design Polyatomic Interferences Typically, most polyatomic interferences are only present below mass 82 - since Ar, H, and O are by far the most abundant isotopes in the plasma, they form most interferences Counteractive measures: Proper machine settings (especially nebulizer flow rate and RF power) can minimize formation

Sample Analysis Design Polyatomic Interferences If a polyatomic interference is unavoidable, then a correction equation like the one for isobaric interferences can be used (assuming you are certain of the species of the interference)

Sample Analysis Design Refractory Oxides Refractory Oxides Occur because of incomplete sample dissociation or from recombination Always occur as an interference as an integral value of 16 mass units above the interfering element MO, MO 2, or MO 3 where M is the interfering element

Sample Analysis Design Refractory Oxides Elements with high oxide bond strength are most likely to form refractory oxide interferences Severity is expressed as MO/M as a percentage MO/M should be as low as possible, typically <5% MO/M minimized by adjusting nebulizer flow rate, z-axis position, and RF power

Sample Analysis Design Refractory Oxides Si, Ce, Zr, Ti, Sm, Mo, and P all form strong oxide bonds and may have severe oxide interferences Usually monitor the CeO/Ce ratio to make sure it s below 5%

Examples: Sample Analysis Design Refractory Oxides LREE on the HREE BaO on Eu MoO on Cd

Sample Analysis Design Refractory Oxides Again, correction equations can be applied but these lead to increased error, especially if the interference is large Oxide formation tends to not be stable and the corrections accumulate error quickly If there is a severe oxide interference, it s usually better to try to separate the interference from the analyte

Typically, Sample Analysis Design Refractory Oxides MO > MO 2 > MO 3 > MO 4

Sample Analysis Design Doubly Charged Ions Form when the 2nd ionization potential is less than the first ionization potential of Ar Typical of alkaline earths, a few transition metals, and some REE Low nebulizer flow rates increase doubly charged ion formation Interference signal is always M/2 where M is the element becoming doubly charged

How to avoid spectral MS interferences? Attempt to dry solutions prior to introduction to plasma - remove O and H gets rid of many polyatomic species (i.e. use a desolvating introduction system e.g. DSN 100) Optimize instruments settings so that formation is minimized and corrections are not severe Use simple matrices whenever possible Process samples prior to analysis to isolate elements of interest or remove potential interfering elements; e.g. ion exchange chromatography

How to avoid spectral MS interferences? Alternatively - use higher mass resolutions, MR medium resolution or HR high resolution Most overlaps are not exact using medium and high resolution modes Can completely separate the isotope of interest from interfering species However, consequence is loss of sensitivity

Sample Analysis Design PART III Spectroscopic interferences Matrix effects

Matrix Effects Physical physical effects from dissolved or undissolved solids present in solution Chemical Ionization suppression and enhancement effects

Matrix Effects Physical variations in rate of atomization/ionization of samples and standards samples and standards should have similar viscosities matrix acid concentrations should be the same in samples and standards

Matrix Effects Chemical properties of the solution may inhibit or suppress the formation of ions high TDS, refractory species typically increasing RF power or lowering nebulizer flow rates can reduce this type of interference

Matrix Effects Ionization space charge effects

Matrix Effects Effects from high TDS Significant sample drift observed when TDS is > 2000 ug/ml 200 mg of sample in 100 ml of solute rock analysis = 50 mg in 100 ml

Matrix Effects Ways to avoid high TDS effects: most obvious - DILUTE 2nd way - prime the system most high TDS effects will cause signal drift until a lower (or sometimes higher) analyte signal is reached after that point, the change is minimal

Matrix Effects Ion signal Suppression and Enhancement suppression more common than enhancement suppression through space charge effects in general, large concentrations of heavy elements will cause signal suppression through space charge effects S - a classic ion signal suppressor

Matrix Effects Enhancement is more rare as ion signal increases over time are more likely the result of changing machine conditions than true matrix effects Overall - matrix effects caused by low mass elements are poorly understood plasma dynamics? ion transfer changes? supersonic expansion?

Matrix Effects Matrix effects are difficult to quantify Corrections are typically quite error prone Hard to determine if signal degradation is due to instrumental drift or due to suppression/enhancement

Ways to overcome matrix effects? DILUTE internal standarization instrument optimization matrix matching standards and samples standard addition matrix separation

Sample Analysis Design Element2 - Basic Software Concepts

Element2 Software Basic Concepts

Element2 Software Basic Concepts

Element2 Software Basic Concepts

Element2 Software Basic Concepts

Element2 Software Basic Concepts

Element2 Software Method Editor Before you acquire data, you must define a suitable measuring program this results in a Method The Method contains all the parameters: Related to the elements to be measured (e.g. mass range & isotopes) Related to conditions of data sampling (e.g. sample time, samples per peak, replicates- runs & passes) Related to the measuring method (e.g. resolution, scan mode, detection mode)

Element2 Software Method Editor Method editor application features two different views: Periodic system of the elements (PSE) Display of the measuring parameters in spreadsheet format

Method Editor Views

Element2 Software Method Editor TOOL BAR

Software definitions Pass: Defined as one measurement cycle in the selected resolution Run: To improve the statistical numbers, several passes can be combined (averaged) into Runs Scans: The # of scans is the product of the # of runs and the # of passes Scans = Runs * Passes

Settling time for acquisitions using multiple mass resolutions.

Scan Modes Magnetic Scan (BScan): the electric field is kept constant and the magnetic field is varied as a function of time the BScan is suitable for scanning large, continuous mass ranges to obtain a complete spectrum from an unknown sample. for repeated scanning, a fast flight-back follows each scan depending on the (mass) distance for the flight-back, a settling time for the magnet must be allowed the settling time takes into account the time needed for the magnet to recover from the fast flight-back of each cycle this scan mode is also used for Mass Calibration in order to account for the non-linear behavior of the magnet

Scan Modes Electric Scan (EScan): the magnetic field is kept constant and scanning is performed electrically by varying the accelerating voltage and the ESA high voltage this scan mode is the fastest scan the EScan starts with setting the magnet to a mass at the lower end of the Mass Range the available mass range for the electric scan depends on the magnet mass; it ranges from -6% to +30% of the magnet mass

Scan Modes EScan advantages: fast scans can be conducted over the detectable mass range without huge energy transfer in the magnet = this results in settling times that do not have to be observed even when performing the fastest repeated scans thus possible to scan the mass ranges of the isotopic pattern and to skip the ranges of no interest possible to carry out replicate measurements in quick succession because of the low energy transfer the advantages of EScan make it the preferred and default scan mode

Integration Window (%): Expressed as a percentage of the peak width, is used to calculate peak intensity. A value of 100% means that the intensity will be calculated from samples, measured in a window of ± ½ peak width of peak center Peak Search Window (%): This specifies the mass window, where the software performs a search (calculation) for the peak center. For example, a value of 100% means that all samples are used in a window of ± ½ peak width of the accurate mass as specified during the elements/isotope selection.