ODS-UG,HG,MG,SR columns

Similar documents
Shodex TM ODP2 HP series columns

Orosil HPLC Columns. OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph.

Inertsil ODS-EP Technical Information

InertSustainSwift C8

Comparison Guide to C18 Reversed Phase HPLC Columns

ImpSilHPLC Columns. The solution for your chromatography IMPTECH SCIENTIFIC

Capital HPLC Columns and HPLC Cartridges. Optimal HPLC Range

Sunniest C18 Sunniest RP-AQUA Sunniest C8 Patent pending

QUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE. C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3

RP C18 column with feature of a silanol group

Inertsil Technical Library

Hypersil BDS Columns TG 01-05

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents

Silanol. Groups Liquid Chromatography

COMPARISON GUIDE. to C18 Reversed Phase HPLC Columns. Comparison Data on 60 Commonly Used C18 Phases. Stationary Phase Specifications

Advantages of polymerbased. an alternative for ODS

Chemistry Instrumental Analysis Lecture 28. Chem 4631


Optimisil HPLC & UPLC Column catalogue

HPLC Column Material - Bulk Ware

High Performance Liquid Chromatography

High Performance Liquid Chromatography

Method Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples

InertSustainSwift C8

Comparison of different aqueous mobile phase HPLC techniques

Fast Separation of Vastly Different Compounds by Isocratic HPLC

State-of-the-art C18 HPLC Columns

The Retention Behavior of Reversed-Phase HPLC Columns with 100% Aqueous Mobile Phase

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns

LC and LC/MS Column Selection Flow Chart

Packings for HPLC. Packings for HPLC

Thermo Scientific Accucore XL HPLC Columns. Technical Manual

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

An HPLC column offering moderate retentivity with superb peak shape Inertsil ODS Sprint

Introduction to Capillary GC. Page 1. Agilent Restricted February 2, 2011

Thermo Scientific Syncronis HPLC Columns. Remarkable separations guaranteed time after time

Tracer Excel TRACER EXCEL ODS-A. Total deactivation. Maximum Stability

ChromegaChiral TM CSP Media and Columns

Optical Isomer Separation Columns and Packing Materials

Fluophase and Fluofix Columns

Method Development Kits

( )( ) Selectivity Choices in Reversed-Phase Fast LC. Introduction. R s = 1 a 1 k 4 a 1 + k

zorbax Packed by Phenomenex Material Characteristics High efficiency Guaranteed quality Phenomenex columns packed with Zorbax

6 Optical Isomer Separation Columns

Analysis - HPLC A.136. Primesep 5 µm columns B.136

ACE Excel SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

Introduction to Capillary GC

AN HPLC COLUMN InertSustain C1 AN HPLC COLUMN InertSustain C1 Inertsil continues to evolve to InertSustain Physical Properties

LEARNING OBJECTIVES CHEM 212: SEPARATION SCIENCE CHROMATOGRAPHY UNIT. Thomas Wenzel, Bates College. In-class Problem Set Extraction.

Introduction to Capillary GC

ChromegaChiral TM CSP Media and Columns

penta-hilic UHPLC COLUMNS

Ion Exchange Columns ---- Inertsil AX 078 Inertsil CX 080. HPLC Column Catalog

Ion Chromatography *

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

ProntoSIL C18-EPS Reversed-Phase HPLC Columns

Work plan & Methodology: HPLC Method Development

SGE is excited to launch a new HPLC product line under the ProteCol brand.

Part 2. Overview of HPLC Media

Elements and the Periodic Table

Optimized Flash Chromatography Purification: From TLC to large scale in three steps

ACE Ultra Inert Base Deactivated HPLC Columns

HILIC Method Development in a Few Simple Steps

Our Expanding Understanding and Use of Reversed-Phase Column Selectivity

Exceptional Selectivity of Agilent ZORBAX Eclipse Plus Phenyl-Hexyl Columns to Separate Estrogens

SEPARATIONS ESSENTIALS IN MODERN HPLC. 2University of Bucharest, Bucharest, Romania

STUDY OF LOADABILITY AND SELECTIVITY OF PHARMACEUTICAL COMPOUNDS ON RPLC COLUMNS

N α - 1 k. R s = Figure 1: The effect of N, α and k on resolution (Rs)

Chromatography 1 of 26 Boardworks Ltd 2016

LIQUID CHROMATOGRAPHY

HPLC Column Classification

Looking into the HPLC Column while Running CIP

HPLC column C18 C8 PFP. SunShell. Core Shell Particle

CHAPTER CHROMATOGRAPHIC METHODS OF SEPARATIONS

Kromasil. for your analytical HPLC. Kromasil. The way to peak performance in liquid chromatography

Reversed Phase Solvents

Periodic Table Practice Questions

Kinetic & Affinity Analysis

H P L C C O L U M N S

Remember - Ions are more soluble in water than in organic solvents. - Neutrals are more soluble in organic solvents than in water.

P R O D U C T B U L L E T I N. Fused-Core particle technology for hyper-fast and super-rugged HPLC columns

PAPER AND THIN LAYER CHROMATOGRAPHY (TLC)

SELECTING HPLC COLUMNS: GOING UNDER THE HOOD. HPLC Column Selection Guide

HPLC COLUMNS WILEY-VCH. Theory, Technology, and Practice. Uwe D. Neue with a contribution from M. Zoubair El Fallah

HPLC COLUMNS VaRian, inc. Pursuit XRs EXtRa REsolution. Ma XiMuM lifetime. ultimate PERfoRMancE.

Pure Chromatography Consumables Pure flexibility. Pure specialization. Pure convenience.

Functional Genomics Research Stream. Research Meeting: February 7, 2012 Reagent Production, Buffers & ph

Technical Guide Thermo Scientific Syncronis HPLC Columns

ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development

Periodic Table Workbook

Chapter 9 Lesson 1: Substances and Mixtures

Guide to Choosing and Using Polymer Reversed Phase Columns!

Properties of Compounds

Crash Course on Nucleus

State - of - the -art C18 HPLC Columns

THIN LAYER CHROMATOGRAPHY

Next Generation of Phenyl Columns. Chromatography Products.

Alltech Alltima HP Introduction

7. Stability indicating analytical method development and validation of Ramipril and Amlodipine in capsule dosage form by HPLC.

Transcription:

Column for reversed phase ODS-UG,HG,MG,SR columns Develosil ODS-HG Develosil ODS-UG Develosil ODS-MG Develosil ODS-SR The 2nd generation of Develosil series, very standard column This series is the column in which residual silanol by high-grade-ize and double end cap treatment of the silica gel which is a base material was reduced compared with ODS. The peak tailing of a basic compound is suppressed and it has become very user-friendly specification. Physical properties of Develosil ODS-HG, ODS-UG, ODS-MG, ODS-SR Column name Ligand Carbon ODS-UG ODS-HG ODS-MG ODS-SR (Monfunctional) (Trifunctional) (Difunctional) (Difunctional) 18% 18% 15% 18% End Capping Surface area Pore diameter Pore volume 300m 2 /g 14nm 1.05mL/g 400m 2 /g 560m 2 /g 10nm 8nm 1.15mL/g Range of ph ph2-10 ph1-9 ph2-7.5 The combination and the theoretical plate number of a piping inside diameter Column name ODS-UG ODS-HG ODS-MG ODS-SR It is used when using an alkaline mobile phase. It ranks with ODS-HG and is a standard existence. Use It is used when using an acid mobile phase. Although separation almost equivalent to ODS-UG is shown, ODS-HG of solid recognition ability is higher. 2 reaction type ODS. Compared with ODS-UG or HG, retention is a column for a separation improvement strongly. It can be used also for a mobile phase with much water composition. The column which is proud of the retention greatest in a Develosi column The optimal column for earning retention. Loading dose increase of preparative isolation can be aimed at. DB10-0218

The example of analysis of an aromatic compound Nine kinds of aromatic compounds are measured on the terms. Although there is a difference of time in ODS-UG and HG, the almost same separation is shown. Because ODS-MG and SR can obtain quite strong retention compared with this, it becomes the means of a separation improvement. About an improvement of separation For improving separation The length of a column is changed. It changes into the strong column of retention. Particle diameter is made small. Composition is changed. etc. It is necessary to choose the column appropriate for the purposes, such as solubility, analytical time, etc. of a sample.

The means at the time of choosing a column The data in which hydrogen bond property and hydrophobic surface polarity were shown is in below. It has respectively different performance in ODS-UG, HG, and ODS-MG and ODS-SR. Please follow it as the guide of column selection. Hydrogen associativity Hydrogen associativity becomes a parameter for seeing the influence of residual silanol. Compared with ODS-UG or HG, ODS- MG and SR tend to be subject to the influence of residual silanol. But there is also much analysis which is possible only in ODS-MG or SR, and there is. Hydrophobicity Hydrophobicity is a parameter influenced by the carbon content. ODS-MG which has influence of the base material physical properties to be used, and has 15% of carbon content shows hydrophobicity higher than ODS- UG and HG from the size of the surface area.

Durability of a column ODS-UG, HG, MG, and SR as which the new end cap method is adopted are the column excellent also in the durability of liquefaction. Alkali durability of Develosil ODS-UG Peak add up is maintained also 506 hours after setting on the above terms. If the terms from which deterioration does not arise easily are constructed, sufficient durability is shown also on a high ph condition. Acid durability of Develosil ODS-HG When the case where phosphoric acid is used on the above terms, and TFA are used. The change of the later maintenance through the liquid is held in check for 500 hours by several percent of decrease. Therefore, sufficient durability is shown also to an acid mobile phase.

Develosil ODS-MG Maintenance of the retention in many mobile phases in water The phenomenon that maintenance becomes suddenly early is generated in Develosil ODS- HG, UG and the SR in the mobile phase with many 100% of water systems or water systems. ODS-MG can maintain enough maintenance in the above agreement by controlling the matrix surface. Acid durability of Develosl ODS-MG The durability on the acid terms of Develosil ODS-MG on terms is shown. Even if 500 hours pass, retention shows high durability only by reduction of several percent. In operating ph range, ODS-MG shows high durability.

Separation comparison Hydrochloric acid compound As for ODS-UG, HG, and MG, the thing with few impurities which has adopted high purity silica is the feature. It combines with the effect of an end cap and the form of pyridine (basic compound) is also sharp. And, ODS-MG and SR with high surface area show strong retention. Separation comparison Metallic compound Metal compounds as well as a basic compound are subject to the effect of a silica gel statement, and ODS-UG, HG, and MG show good peak shape. In particular, ODS-MG has controlled the joint density in low proportion compared with other three sorts. When separation is insufficient in ODS-UG or HG, the width examined since it has reproducibility sufficient also by a mobile phase with much water composition used as the means of a separation improvement can be expanded.

Separation comparison Acidic compound It has set to comparison of the organic acid and, in a gap, good form is shown. When ODS-HG and UG are made into a standard, ODS-MG and SR have retention in a strong tendency. Thus, ODS differs in a result greatly in the column to be used. 10060 Carroll Canyon Rd., Ste 100 San Diego, CA 92131 Phone: (858) 800-2433 info@develosil.us www.develosil.us