Department of Mathematics, Amrita Vishwa Vidyapeetham (University), Karnataka , India

Similar documents
Biomagnetic Steady Flow through an Axisymmetric Stenosed Artery

A Computational study of Bingham plastic flow of Blood through an artery by multiple stenoses and post dilatation

Simulation of Variable Viscosity and Jeffrey Fluid Model for Blood Flow Through a Tapered Artery with a Stenosis

Analytical Solutions of Unsteady Blood Flow of Jeffery Fluid Through Stenosed Arteries with Permeable Walls

Effect of Magnetic Field on Blood Flow (Elastico- Viscous) Under Periodic Body Acceleration in Porous Medium

STUDY OF BLOOD FLOW THROUGH MODELLED VASCULAR STENOSIS

Effect of body acceleration on pulsatile blood flow through a catheterized artery

Available online at Pelagia Research Library. Advances in Applied Science Research, 2012, 3 (6):

Effect of Magnetic Field on Flow Behaviour of Blood through A Modelled Atherosclerotic Artery

Pulsatile Flow of Couple Stress Fluid Through a Porous Medium with Periodic Body Acceleration and Magnetic Field

Flow of a Casson Fluid Through an Inclined Tube of Non-uniform Cross Section with Multiple Stenoses

Research Article FDM Analysis for Blood Flow through Stenosed Tapered Arteries

MHD Pulsatile Slip Flow of Blood through Porous Medium in an Inclined Stenosed Tapered Artery in Presence of Body Acceleration

Mathematical modelling of blood flow through a tapered overlapping stenosed artery with variable viscosity

Radial Variation of Axial and Radial Velocity of Blood in Stenosed Artery in the Presence of Body Accelerations

Modeling of non-newtonian Blood Flow through a Stenosed Artery Incorporating Fluid-Structure Interaction

Mathematical Modelling of Blood Flow through Catheterized Artery under the Influence of Body Acceleration with Slip Velocity

Effect of Periodic Body Acceleration in Blood Flow through Stenosed Arteries A Theoretical Model

Numerical Study of the Behaviour of Wall Shear Stress in Pulsatile Stenotic Flows

Effects of Magnetic Field and Slip on a Two-Fluid Model for Couple Stress Fluid Flow through a Porous Medium

Suspension model for blood flow through a tapering catheterized inclined artery with asymmetric stenosis

Blood flow through arteries in a pathological state: A theoretical study

Peristaltic Transport of a Magneto Non-Newtonian Fluid through A porous medium in a horizontal finite channel

Mathematical modelling of blood flow through a tapered overlapping stenosed artery with variable viscosity

World Journal of Engineering Research and Technology WJERT

Arterial Macrocirculatory Hemodynamics

Peristaltic flow of a Williamson fluid in an inclined planar channel under the effect of a magnetic field

Research Article Nonlinear Fluid Models for Biofluid Flow in Constricted Blood Vessels under Body Accelerations: A Comparative Study

Numerical Study of Blood Flow through Symmetry and Non- Symmetric Stenosis Artery under Various Flow Rates

MHD peristaltic transport of a micropolar fluid in an asymmetric channel with porous medium

Numerical simulation of blood flow in a straight artery under the influence of magnetic field

Numerical study of blood fluid rheology in the abdominal aorta

Unsteady Flow of a Newtonian Fluid in a Contracting and Expanding Pipe

MHD OSCILLATORY SLIP FLOW AND HEAT TRANSFER IN A CHANNEL FILLED WITH POROUS MEDIA

Velocity Profiles of Unsteady Blood Flow through an Inclined Circular Tube with Magnetic Field

Magnetic Effect on Slip Flow of Blood through Porous Medium with Time Dependent Permeability, Pulsatile Pressure and Body Acceleration

Hydromagnetic Blood Flow through a Uniform Channel with Permeable Walls Covered by Porous Media of Finite Thickness

Modelling and simulation of micropolar fluid flow with variable viscosity through unhealthy artery

Mathematical Model of Blood Flow in Carotid Bifurcation

Magnetic effects on pulsatile flow of micropolar fluid through a bifurcated artery

Analytical Solutions on the Flow of blood with the Effects of Hematocrit, Slip and TPMA in a porous tube

Mathematical Models and Numerical Simulations for the Blood Flow in Large Vessels

Research Article Peristaltic Transport of a Jeffrey Fluid with Variable Viscosity through a Porous Medium in an Asymmetric Channel

International Journal of Mathematical Archive-7(5), 2016, Available online through ISSN

Experimental Investigation on Characteristics of Non- Newtonian Fluids

Influence of velocity slip conditions on MHD peristaltic flow of a Prandtl fluid in a non-uniform channel

Slip Effect on Peristaltic Transport. of Micropolar Fluid

INTERNATIONAL JOURNAL OF ADVANCE RESEARCH, IJOAR.ORG ISSN

BHAVYA TRIPATHI AND BHUPENDRA KUMAR SHARMA. Abstract

CENG 501 Examination Problem: Estimation of Viscosity with a Falling - Cylinder Viscometer

MHD PERISTALTIC FLOW OF A COUPLE STRESS FLUIDS PERMEATED WITH SUSPENDED PARTICLES THROUGH A POROUS MEDIUM UNDER LONG WAVELENGTH APPROXIMATION

Oscillatory flow of a jeffrey fluid in an elastic tube of variable cross-section

Research Article Innovation: International Journal of Applied Research; ISSN: (Volume-2, Issue-2) ISSN: (Volume-1, Issue-1)

Numerical Study of Steady MHD Plane Poiseuille Flow and Heat Transfer in an Inclined Channel

Numerical modelling of shear-thinning non-newtonian flows in compliant vessels

Numerical Solution of Mass Transfer Effects on Unsteady Flow Past an Accelerated Vertical Porous Plate with Suction

Study of blood flow through a catheterized artery

Hydromagnetic oscillatory flow through a porous medium bounded by two vertical porous plates with heat source and soret effect

MHD FORCED FLOW OF A CONDUCTING VISCOUS FLUID THROUGH A POROUS MEDIUM INDUCED BY AN IMPERVIOUS ROTATING DISK

Unsteady Hydromagnetic Couette Flow within a Porous Channel

Flow of a Newtonian fluid in a non-uniform wavy and permeable tube

Hiromi Nishida. 1. Introduction. 2. Materials and Methods

Mathematical modelling of physiological flows

Peristaltic Pumping of a Casson Fluid in an Elastic Tube

PROBLEM SET 6. SOLUTIONS April 1, 2004

*Corresponding Author: Surajit Dutta, Department of Mathematics, C N B College, Bokakhat, Golaghat, Assam, India

Effect of Couple Stresses on the MHD of a Non-Newtonian Unsteady Flow between Two Parallel Porous Plates

Transient free convective flow of a micropolar fluid between two vertical walls

SIMULATION OF ARTERIAL STENOSIS INCORPORATING FLUID-STRUCTURAL INTERACTION AND NON-NEWTONIAN BLOOD FLOW

Research Article Analytic Solution for MHD Falkner-Skan Flow over a Porous Surface

Modeling of arterial stenosis and its applications to blood diseases

Impact of Magnetic Field Strength on Magnetic Fluid Flow through a Channel

Peristaltic Transport of a Hyperbolic Tangent Fluid Model in an Asymmetric Channel

Heat and Mass Transfer Effects of Peristaltic Transport of a Nano Fluid in Peripheral layer

Effect of variable viscosity on the peristaltic flow of a Jeffrey fluid in a uniform tube

BME 419/519 Hernandez 2002

MAGNETOHYDRODYNAMIC FLOW OF VISCOUS ELECTRICALLY CONDUCTING INCOMPRESSIBLE FLUID THROUGH VERTICAL PLATES SUBJECTED TO INCLINED MAGNETIC FIELD.

Numerical Simulation of Sinusoidal Fluctuated Pulsatile Laminar Flow Through Stenotic Artery

Theoretical Study of Heat Transfer on Peristaltic Transport of Non- Newtonian Fluid Flowing in a Channel: Rabinowitsch Fluid Model

Mathematical Modeling of Peristaltic Flow of Chyme in Small Intestine

arxiv: v2 [physics.flu-dyn] 26 Jul 2018

ROTATING OSCILLATORY MHD POISEUILLE FLOW: AN EXACT SOLUTION

V (r,t) = i ˆ u( x, y,z,t) + ˆ j v( x, y,z,t) + k ˆ w( x, y, z,t)

Experimental and Theoretical Investigation of Hydrodynamics Characteristics and Heat Transfer for Newtonian and Non-newtonian Fluids

NUMERICAL SOLUTION OF MHD FLOW OVER A MOVING VERTICAL POROUS PLATE WITH HEAT AND MASS TRANSFER

Laplace Technique on Magnetohydrodynamic Radiating and Chemically Reacting Fluid over an Infinite Vertical Surface

Candidates must show on each answer book the type of calculator used. Only calculators permitted under UEA Regulations may be used.

This article appeared in a journal published by Elsevier. The attached copy is furnished to the author for internal non-commercial research and


Non-Newtonian blood flow in human right coronary arteries: steady state simulations

Effects of Hall Current and Rotation on Unsteady MHD Couette Flow in the Presence of an Inclined Magnetic Field

Hartmann Flow in a Rotating System in the Presence of Inclined Magnetic Field with Hall Effects

Corresponding Author: Kandie K.Joseph. DOI: / Page

Exact Solutions of Brinkman Type Fluid Between Side Walls Over an Infinite Plate

TECHNISCHE UNIVERSITEIT EINDHOVEN Department of Biomedical Engineering, section Cardiovascular Biomechanics

STEADY VISCOUS FLOW THROUGH A VENTURI TUBE

OPTIMALITY TO FLOW AND DESIGN OF BRANCHING DUCTS

Hall Effects on MHD Flow in a Rotating Channel in the Presence of an Inclined Magnetic Field

Week 8. Topics: Next deadline: Viscous fluid flow (Study guide 14. Sections 12.4 and 12.5.) Bolus flow (Study guide 15. Section 12.6.

Creeping Flow of Viscous Fluid through a Proximal Tubule with Uniform Reabsorption: A Mathematical Study

Transcription:

Journal of Biophysics, Article ID 797142, 9 pages http://dx.doi.org/10.1155/2014/797142 Research Article Analysis of Flow Characteristics of the Blood Flowing through an Inclined Tapered Porous Artery with Mild Stenosis under the Influence of an Inclined Magnetic Field Neetu Srivastava Department of Mathematics, Amrita Vishwa Vidyapeetham (University), Karnataka 560 035, India Correspondence should be addressed to Neetu Srivastava; s neetu@blr.amrita.edu Received 27 November 2013; Accepted 6 January 2014; Published 25 February 2014 Academic Editor: Jianwei Shuai Copyright 2014 Neetu Srivastava. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. Analytical investigation of MHD blood flow in a porous inclined stenotic artery under the influence of the inclined magnetic field has been done. Blood is considered as an electrically conducting Newtonian fluid. The physics of the problem is described by the usual MHD equations along with appropriate boundary conditions. The flow governing equations are finally transformed to nonhomogeneous second-order ordinary differential equations. This model is consistent with the principles of magnetohydrodynamics. Analytical expressions for the velocity profile, volumetric flow rate, wall shear stress, and pressure gradient have been derived. Blood flow characteristics are computed for a specific set of values of the different parameters involved in the model analysis and are presented graphically. Some of the obtained results show that the flow patterns in converging region (ξ <0), diverging region (ξ >0), and nontapered region (ξ =0) are effectively influenced by the presence of magnetic field and change in inclination of artery as well as magnetic field. There is also a significant effect of permeability on the wall shear stress as well as volumetric flow rate. 1. Introduction Blood is a thick red liquid circulating in the blood vessels. It has a strong nourishing effect on the human body and serves as one of the basic substances constituting the human body. Blood is a suspension of cellular elements red blood cells (erythrocytes), white blood cells (leukocytes), and platelets in an aqueous electrolyte solution called plasma. Plasma contains 90% of water and 7% of principal proteins (albumin, globulin, lipoprotein, and fibrinogen). The volumetric fraction of the erythrocytes is 45% of the total volume of blood in normal blood, which defines an important variable called hematocrit. Of the remaining blood cells, the leukocytes are less than (1/600)th of the red blood cells and the platelets concentration is (1/20)th of the red blood cells. Hemodynamics describes the mechanism that affects the dynamicsofbloodcirculationinthehumanbody.underthis, atherosclerosis, a leading cause of death in many countries, is one of the phenomena in which the blood circulation will get affected by the intimal thickening of stenos artery. A blockage by atherosclerosis, which is a progressive vascular disease that causes accumulation of fatty substances, calcium, fibrin, cellular waste, and cholesterol, also known as plaque, inside the walls of the arteries, leads to the narrowing of the walls of the arteries and causes the condition known as carotid artery disease. Severe stenosis may cause critical flow conditions of blood by reducing the blood supply and resulting in serious consequences called carotid artery blockage which is one of the major contributing factors to strokes. This is because when the plaque hardens and narrows down the arteries completely, the blood supply and oxygen to the brain are reduced. Without proper blood or oxygen supply, the cells in the brain start to die. This leads to the loss of brain function and permanent brain damage or the death of an individual. However, the chances of developing carotid artery disease may increase as a result of carotid aneurysm disease, fibromuscular dysplasia, or diabetes. In certain cases, plaque builtupinthearteriescanbreakoff,travelthroughthe bloodstream, and get lodged in some blood vessels in the

2 Journal of Biophysics (a) (b) Figure 1: Atherosclerosis. r L r a b d 0 h(z) z n=2 n=6 n=11 Figure 2: Schematic diagram for the porous artery with the different stenosis. brain. This can trigger off a transient ischemic attack. It is thus vital to watch out for the symptoms of a carotid artery blockage, so that necessary steps can be taken before the individual s condition worsens. The problem of fluid mechanics has attracted the attention of many investigators. If fluid is considered as blood, then the equation of motion suggested by the [1, 2] canbe modified and can be used to gather an accurate knowledge of the mechanical properties of the vascular wall together with the flow characteristics of blood, in order to have a full understanding of the development of these diseases, which will assist bioengineers who are engaged in the design and construction of improved artificial organs and also helps in the treatment of vascular diseases. Perhaps the actual cause of abnormal growth in arteries is not completely clear to the theoretical investigators but its effect on the cardiovascular system has been determined by studying the flow characteristics of blood in the stenosed area. Although the applicability of a purely mechanical model for such a physiological problem has obvious limitations, vascular rheology together with hemodynamic factors is predominant inthedevelopmentandprogressionofarterialstenosis. The idea of electromagnetic fields in medical research was firstly given by Kolin [3], and later Korchevskii and Marochnik [4] discussed the possibility of regulating the movement of blood in human system by applying magnetic field. Vardanyan [5] studied the effect of magnetic field on blood flow theoretically and his work was later corroborated by Sud et al. [6]andSuriandSuriPushpa[7] by considering different models. It was observed by these authors that the effect of magnetic field is to slow down the speed of blood. However, the published literature lacks the analysis of magnetic effect on blood flow through an inclined branched artery. If a magnetic field is applied to a moving electrically conducting liquid, it induces electric and magnetic fields. The interaction of these fields produces a body force known as Lorentz force which has a tendency to oppose the movement oftheliquid.fortheflowofbloodinarterieswitharterial disease like arterial stenosis or arteriosclerosis, the influence of magnetic field may be utilized as a blood pump in carrying out cardiac operations, and in addition to this, the effects of vessels tapering together with the shape of stenosis on the flow characteristics seem to be equally important and deserve special attention. Chakraborty et al. [8] discussedthesuspensionmodel bloodflowthroughaninclinedtubewithanaxiallynonsymmetric stenosis. Eldesoky [9] studied the slip effect of unsteady magnetic field on pulsatile blood flow through porous medium in an artery under the effect of body acceleration. Bali and Awasthi [10] studied the Newtonian blood flow

Journal of Biophysics 3 Diverging region,ξ> 0 Nontapered region, ξ=0 L Converging region,ξ< 0 a+b a α M Figure 3: Schematic diagram for the tapered porous artery inclined at an angle α and with the applied magnetic field inclined at θ. r τ 0.1 0.2 0.3 0.4 0.2 0.4 0.6 0.8 1.0 n=2 n=6 n=11 0.5 0.6 0.7 κ = 0.1 κ = 0.5 Figure 4: Effect of permeability on the shearing stress for different values of shape parameter n and permeability. through the tapered arteries. The important contributions of recent years to the topic are referenced in the literature [11 19]. However, the published work still lacks the analysis of the blood flow characteristics through an inclined artery with the applied magnetic field. This problem has taken a care for this. In this paper, we have considered the effects of arterial wall parameters on the flow of Newtonian fluid (as a blood model) through an inclined tapered porous artery with axially nonsymmetric mild stenosis under effect of an external inclined magnetic field (Figure 2). 2. Formulation of the Problem Consider an axisymmetric steady flow of blood with a constant viscosity μ and density ρ in a cylindrical porous artery of radius d 0 and length L inclined at an angle α represented in Figure 1. Letθ be an angle of inclined magnetic field externally applied to an inclined porous artery (Figure 3). Let (r, φ, z) be the cylindrical polar coordinates with r = 0 as the axis of symmetry of the tube. Let us define V r, V φ, V z as components of velocity. Since the flow is axisymmetric, so variation in the blood flow characteristic is independent of an azimuthal angle. The geometry of stenosis is defined by d (z) [1 η (b n 1 (z a) { h (z) = { (z a) 2 )], a z a + b, (1) { d (z), otherwise, with d (z) =d 0 +ξz, (2) where d(z) is the radius of tapered arterial segment in the stenotic region, d 0 is the radius of the nontapered artery in the nonstenotic region, ξ is the tapering parameter, b is the length of thestenosis, andn( 2) is a parameter determining the shape constriction profile and referred to as a shape parameter. The parameter η is defined by η= δn(1/(n 1)) d 0 b n (n 1), (3) where δ denotes the maximum height of the stenosis located at b z=a+. (4) n (1/(n 1))

4 Journal of Biophysics r τ 0.2 0.4 0.6 0.8 0.2 0.4 0.6 0.8 1.0 Diverging region,ξ> 0 Nontapered region, ξ=0 Converging region,ξ< 0 α=π/3 α=π/9 Figure 5: Effect of artery inclination on the shearing stress for different values of tapering angle ξ. 1.0 κ = 0.1 1.5 τ 2.0 2.5 3.0 κ=1 κ = 0.5 0.00 0.05 0.10 0.15 0.20 α=π/3 α=π/9 Figure 6: Variation of shearing stress at the stenosis throat δ with different inclination for α different values of permeability parameter κ. δ The equation describing the steady flow of blood through the cylindrical artery inclined at an angle α can be written as follows: V =0, (5) ρf = p+μ 2 V μv κ + JXB. (6) Boundary conditions for the given problem can be written as follows: u=0 at r=h(z), θ, κ is the permeability of the porous medium, g is the acceleration due to gravity, and μ is the viscosity of the blood. 3. Equation of Motion Introducing the nondimensional variables as follows: z = z d, r = r d 0, h = h d 0, u r =0 at r=0, u is finite at r=0. Based on the assumption made for the flow, (5) canbe reduced to ρg sin α= p u z +μ( 2 r 2 + 1 u r r ) μu κ σb2 0u, (8) where α is the angle of inclination of an artery, ρ is the fluid density, B 0 isanappliedmagneticfieldwithaninclination (7) V = bv δu 0, u = u u 0, h = h d 0, p = pd2 0 bμu 0, Re = ρu 0d 0 μ, κ = κ d0 2, Fr = u2 0 gd 0, M = σd2 0 B2 0 μ, (9)

Journal of Biophysics 5 u 0.8 0.6 0.4 δ=0 κ=1 κ=2 0.2 δ = 0.2 0.4 0.2 z 0.2 0.4 Figure 7: Variation of axial velocity u with z and height of stenosis δ for different values of permeability. 0.35 M=2 u 0.30 0.25 M=3 M=4 ξ = 0.005 ξ = 0.005 0.2 ξ = 0.0 0.1 0.1 0.2 Figure8: Variation of axial velocity u with magnetic field for different values of tapering angle. where Re, Fr, and M define the Reynolds number, Froude number, and Hartmann number, respectively. Substituting (9)in(8),we can have a dimensionless form for(8) as follows: Re u sin α= p Fr z +μ( 2 r 2 + 1 u r r ) ( 1 κ +M2 cos 2 θ) u. (10) As the flow is steady and axisymmetric, let the solution for u(r, t) and p be set in the forms: u (r, t) = u (r), p =P, (11) z where P is a constant. Substituting (11)in(10), we can have an ordinary differential equation as follows: d 2 u dr 2 + 1du rdr β2 u= Re sin α P, (12) Fr where β 2 =(1/κ+M 2 cos 2 θ). The solution for the equation of motion (12) canbe written as follows: κ u (r) =( κ+m 2 cos 2 θ )(Re Fr sin α P) [ I 0 (βr) I 0 (βh) 1], (13) where I 0 is the modified Bessel function of the zero order. The volumetric flow rate can be given by h Q=2π ru dr. (14) 0 Substituting (13) with(14) and integrating it, we get Q= 1 β 2 (Re sin α P)( h2 Fr 2 + h β I 1 (βh) I 0 (βh) ), (15) where I 1 is the Bessel function of the order one. The expression for the wall shear stress at r=hcanbewritten as follows: τ r = μ β (Re Fr sin α P) (I 1 (βh) ). (16) I 0 (βh) 4. Results In a converging and diverging region, for the analysis of the salientfeaturesofthebloodflow,theeffectofvitalparameters defining flow geometries and fluid behaviour such as permeability, Hartmann number, and inclination angle of artery (α) as well as the inclination of magnetic field (θ) on the flow characteristic such as wall shear stress, shear stress at stenosis throat, axial velocity, and the volumetric flow rate are discussed numerically with computational illustrations. All graphs are plotted for the values of σ = b/a = 0, b=1,

6 Journal of Biophysics u 0.694 0.692 0.690 0.688 0.686 0.684 α=0 α=π/6 α=π/3 ξ. 0.10 0.05 r 0.05 0.10 Figure 9: Variation of axial velocity u with z for different values of artery angle α. 0.56698 0.56696 0.56694 0.56692 0.56690 0.56688 0.56686 θ=π/6 θ=0 θ=π/3 θ=π/9 0.010 0.005 0.000 0.005 0.010 Figure 10: Axial velocity with the inclination of magnetic field θ for Re = 0.1,Fr= 0.1, κ=2, M=2,andα=π/3. ξ=tan φ = 0.002, 0, 0.002, Re= 0.1, Fr= 0.1, M=2,3, and 4, shape parameter n=2, 6, and 11, and stenosis height =0to.20 using Mathematica software. Figure 4 indicates that the behaviour of wall shear stress is inversely proportional to the permeability, and with the increase of shape parameter, the wall shear stress increases. For the symmetric stenosis (n = 2), thewallshearstressis less as compared to the asymmetric stenosis (n = 6, 11).Also, with the decrease of permeability parameter, the graph tends towards the parabolic nature, and also shear stress decreases with an increase of permeability parameter. Figure 5 represents the behaviour of shearing stress with the inclination of artery for the different values of tapering angle.ithasbeenobservedthatfortheconvergingregion (ξ < 0), the stress will be more as compared to the diverging region (ξ > 0) and the nontapered region (ξ = 0) that is. Wall shear stress increases with an increase in tapering angle (φ) which is in agreement with Chaturani and Prahlad s model [20]. Figure 6 represents the behaviour of shearing stress with the stenosis throat for the different values of inclination of artery. It has been observed that with the increase of α, the shearing stress τ increases and also the variation of permeability parameter affects the stress inversely. This graph also reveals that with the increase of stenosis height the shearing stress increases. It rapidly decrease in the downstream and maximum value is near the end of the stenosis. This is in agreement with Young s model [19]. Figure 7 represents the behaviour of axial velocity with the stenosis height for different values of permeability. It has been observed that the axial velocity possesses reverse behaviour on the either side of the centreline of the artery. This figure also shows an increase in axial velocity with the increase of permeability. Figure 8 represents the behaviour of axial velocity with the magnetic field for a different tapering angle. It has been observed that with the increase of magnetic field the axial velocity shows a reverse behaviour. It is observed that with the increase of magnetic field, the curves representing the axial flow velocity do shift towards the origin for a converging region, while they shift away from the origin for a nontapered and diverging tapered artery. Figure 9 represents the behaviour of axial velocity for different values of artery inclination and shows the remarkable changes with the inclination of artery. It has been observed that with the increase of inclination of artery, the curve representing the axial flow velocities does shift towards the origin. Figure 10 represents that the axial velocity variation with the inclination of magnetic field.it has been observed that with the increase of inclination of magnetic field, the curve does shift towards the origin.

Journal of Biophysics 7 0.14 0.12 0.10 M=2 M=3 Q 0.08 0.06 M=4 0.2 0.1 n=6 n=2 0.04 ξ M=2 M=3 M=4 0.1 0.2 Figure 11: Variation of volumetric flow rate with the tapering angle, for different values of M and for fixed values of Re = 0.1, Fr = 0.1, α=π/3,andκ=2. α=0 0.12 0.11 Q 0.10 0.09 α=π/6 α=π/3 α=0 α=π/6 α=π/3 0.02 0.01 n=11 n=6 ξ 0.01 0.02 Figure 12: Variation of volumetric flow rate with the angle of inclination α of artery for converging, diverging region, and nontapered region. Figure 11 reveals that the variation of volumetric flow rate for an inclined artery will decrease with the Hartmann number for the fixed values of Reynolds number Re = 0.1, Froude number Fr = 0.1, artery inclination = π/3,and permeability parameter κ = 2, but it will be greater in diverging region as compared to converging region. Figure 12 reveals the information about that variation of volumetricflowratewiththeangleofinclination α ofartery for converging, diverging region, and nontapered region. It shows that with the increase of α the volumetric flow rate decreases. Figure 13 reveals that the variation of volumetric flow rate with the angle of magnetic field θ will increase for all converging (ξ < 0), diverging region (ξ > 0), and nontapered region (ξ = 0). 5. Conclusion The present study deals with the analysis of flow characteristics of the blood flowing through an inclined tapered porous artery with mild stenosis under the influence of an inclined magnetic field. This investigation can play a vital role in the determination of axial velocity, shear stress, and fluid acceleration in particular situations. Since this study has been carried out for a situation when the human body is subjected to an external magnetic field, it bears the promise of significant application in magnetic or electromagnetic therapy, which has gained enough popularity. The study is also useful for evaluating the role of porosity. The analysis is carried out by employing appropriate analytical methods, and some important predictions have been made basing upon the study. The main findings of the present mathematical analysis are as follows. (i)thebehaviourofwallshearstressisinverselyproportionaltothepermeability,andwiththeincreaseof shape parameter, the wall shear stress increases. Wall shear stress increases with an increase of tapering angle (φ) which is in agreement with Chaturani and Prahlad s model [20]. (ii) Shearing stress τ rapid decrease in the downstream andmaximumvalueisneartheendofthestenosis. ThisisinagreementwithYoung smodel[19].

8 Journal of Biophysics 0.115 0.110 θ =0 θ =π/3 θ =π/6 Q 0.105 0.100 0.095 θ =0 θ =π/6 θ =π/3 0.02 0.01 ξ 0.01 0.02 n=11 n=6 Figure 13: Variation of volumetric flow rate with the angle of magnetic field θ for converging, diverging region, and nontapered region. (iii) Concerning the behaviour of axial velocity with the stenosis height for different values of permeability, it hasbeenobservedthattheaxialvelocitypossesses reverse behaviour on either side of the centreline of the artery. (iv) With the increase of magnetic field, the axial velocity showsareversebehaviour.itisobservedthatwith theincreaseofmagneticfield,thecurvesrepresenting the axial flow velocity do shift towards the origin for a converging region, while they shift away from the origin for a nontapered and diverging tapered artery. (v) Axial velocity shows the remarkable changes with the inclination of artery. It has been observed that with theincreaseofinclinationofartery,thecurverepresenting the axial flow velocities does shift towards the origin. (vi) The volumetric flow rate increases with the increase of shape parameter n anddecreaseswiththeincreaseof Hartmann number. Also, Figure 11 shows an increasing behaviour of volumetric flow rate from converging to diverging region. (vii) The variation of volumetric flow rate for an inclined artery will be greater in diverging region as compared to converging region. (viii) Volumetric flow rate varies inversely with the angle of inclination α of artery for converging, diverging region, and nontapered region. (ix) With the angle of inclination of magnetic field θ, the volumetric flow rate will increase and will be more for diverging region as compared to converging region. Conflict of Interests The author declares that there is no conflict of interests regarding the publication of this paper. Acknowledgments The author would like to thank the college authorities for their constant support and encouragement and referee for his valuable suggestions that lead to the improvement of this paper. References [1] H. Darcy, The Flow of Fluids Through Porous Media, Mc-Graw Hill,NewYork,NY,USA,1937. [2] H. C. Brinkman, A calculation of the viscous force exerted by a flowing fluid on a dense swarm of particles, Applied Scientific Research,vol.1,no.1,pp.27 34,1949. [3] A. Kolin, Electromagnetic flow meter: principle of method and its applications to blood flow measurement, in Proceedings of the Society for Experimental Biology and Medicine, vol.35,pp. 53 56, 1936. [4] E. M. Korchevskii and L. S. Marochnik, Magnetohydrodynamic version of movement of blood, Biophysics, vol. 10, no. 2, pp. 411 414, 1965. [5] V. A. Vardanyan, Effect of a magnetic field on blood flow, Biophysics,vol.18,no.3,pp.515 521,1973. [6] V. K. Sud, P. K. Suri, and R. K. Mishra, Effect of magnetic field on oscillating blood flow in arteries, Studia Biophysica,vol.46, no.3,pp.163 171,1974. [7]P.K.SuriandR.SuriPushpa, Bloodflowinabranched arteries, Indian Journal of Pure and Applied Mathematics, vol. 12, pp. 907 918, 1981. [8] U. S. Chakraborty, D. Biswas, and M. Paul, Suspension model blood flow through an inclined tube with an axially nonsymmetrical stenosis, Korea Australia Rheology Journal,vol.23, no. 1, pp. 25 32, 2011. [9] I. M. Eldesoky, Slip effects on the unsteady MHD pulsatile Blood flow through porous medium in an artery under the effect of body acceleration, International Journal of Mathematics and Mathematical Sciences, vol. 2012, Article ID 860239, 26 pages, 2012. [10] R. Bali and U. Awasthi, Mathematical model of blood flow in the small blood vessel in presence of magnetic field, Applied Mathematics,vol.2,pp.264 269,2011. [11] M. Jain, G. C. Sharma, and R. Singh, Mathematical modelling of blood flow in a stenosed artery under MHD effect through

Journal of Biophysics 9 porous medium, International Journal of Engineering, Transactions B,vol.23,no.3-4,pp.243 251,2010. [12] P. K. Mandal, An unsteady analysis of non-newtonian blood flow through tapered arteries with a stenosis, International Journal of Non-Linear Mechanics, vol.40,no.1,pp.151 164, 2005. [13] K. S. Mekheimer and M. A. E. Kot, The micropolar fluid model for blood flow through a tapered artery with a stenosis, Acta Mechanica Sinica,vol.24,no.6,pp.637 644,2008. [14] G. Ramamurty and B. Shanker, Magnetohydrodynamic effects on blood flow through a porous channel, Medical, Bioengineering and Computing,vol.32,no.6,pp.655 659,1994. [15] L. M. Srivastava, Flow of couple stress fluid through stenotic blood vessels, Journal of Biomechanics, vol.18,no.7,pp.479 485, 1985. [16] D. Tripathi, A mathematical model for blood flow through an inclined artery under the influence of an inclined magnetic field, Journal of Mechanics in Medicine and Biology,vol.12,pp. 1 18, 2012. [17] E. E. Tzirtzilakis, A mathematical model for blood flow in magnetic field, Physics of Fluids, vol. 17, no. 7, 15pages, 2005. [18] N. Verma and R. S. Parihar, Effect of Magnetohydrodynamics andhematocritonbloodflowinanarterywithamultiple mild stenosis, International Journal of Applied Mathematics and Computation,vol.1,no.1,pp.30 46,2009. [19] D. F. Young, Fluid mechanics of arterial stenosis, Journal of Biomechanical Engineering ASME,vol.101,pp.157 175,1968. [20] P. Chaturani and R. N. Pralhad, Blood flow in tapered tubes with biorheological applications, Biorheology,vol.22,no.4,pp. 303 314, 1985.

International Journal of Peptides BioMed Research International Advances in Stem Cells International Virolog y International Journal of Genomics Journal of Nucleic Acids Zoology International Journal of Submit your manuscripts at The Scientific World Journal Journal of Signal Transduction Genetics Research International Anatomy Research International Enzyme Research Archaea Biochemistry Research International International Journal of Microbiology International Journal of Evolutionary Biology Molecular Biology International Advances in Bioinformatics Journal of Marine Biology