What is Chromatography?

Similar documents
Chapter 1. Chromatography. Abdul Muttaleb Jaber

Introduction to Chromatographic Separations

1.1 General concepts of analytical chromatography

Introduction to Chromatography

Analytical Chemistry

Chromatographic Separation

Instrumental Analysis II Course Code: CH3109. Chromatographic &Thermal Methods of Analysis Part 1: General Introduction. Prof. Tarek A.

Instrumental Chemical Analysis

Chromatography. Gas Chromatography

Introduction to Chromatographic Separations (Chapter 1) Many determinations involve separation followed by analysis chromatography electrophoresis

Chapter 23 Introduction to Analytical Separations

Separation Methods Based on Distributions in Discrete Stages (02/04/15)

Chromatography Outline

Remember - Ions are more soluble in water than in organic solvents. - Neutrals are more soluble in organic solvents than in water.

CHROMATOGRAPHY (I): BASIS OF ELEMENTAL CHROMATOGRAPHY

Chapter 26: An Introduction to Chromatographic Separations

HPLC Background Chem 250 F 2008 Page 1 of 24

CHROMATOGRAPHY. The term "chromatography" is derived from the original use of this method for separating yellow and green plant pigments.

Chapter 26. An Introduction to Chromatographic Separations. Chromatography

Information given in these slides are, either in part or all, recollection from the followings:


Chromatography and other Separation Methods

Gas Chromatography. Vaporization of sample Gas-solid Physical absorption Gas-liquid Liquid immobilized on inert solid

Chromatographic Analysis

CHEM 429 / 529 Chemical Separation Techniques

Course goals: Course goals: Lecture 1 A brief introduction to chromatography. AM Quality parameters and optimization in Chromatography

LEARNING OBJECTIVES CHEM 212: SEPARATION SCIENCE CHROMATOGRAPHY UNIT. Thomas Wenzel, Bates College. In-class Problem Set Extraction.

Analytical Technologies in Biotechnology Dr. Ashwani K. Sharma Department of Biotechnology Indian Institute of Technology, Roorkee

High Performance Liquid Chromatography

Volatile organic compounds (VOCs):

Liquid Chromatography

Skoog/Holler/Crouch Chapter 26 Principles of Instrumental Analysis, 6th ed. CHAPTER 26

Principles of Gas- Chromatography (GC)

Separations---Chromatography and Electrophoresis

CHAPTER 1. Introduction, Chromatography Theory, and Instrument Calibration

Chapter 27: Gas Chromatography. Principles Instrumentation Detectors Columns and Stationary Phases Applications

Chapter content. Reference

Chromatographie Methods

2] The plate height in chromatography is best described as 2

An Introduction to Chromatographic Separations

Abstract: An minimalist overview of chromatography for the person who would conduct chromatographic experiments, but not design experiments.

Chromatography- Separation of mixtures CHEM 212. What is solvent extraction and what is it commonly used for?

Chromatographic Methods of Analysis Section: 5 Gas Chromatography (GC) Prof. Tarek A. Fayed

Biochemistry. Biochemical Techniques HPLC

ERT320 BIOSEPARATION ENGINEERING CHROMATOGRAPHY

Chromatographic Methods: Basics, Advanced HPLC Methods

PRINCIPLES AND APPLICATION OF CHROMATOGRAPHY. Dr. P. Jayachandra Reddy Mpharm PhD Principal & professor KTPC

Experiment UPHPLC: Separation and Quantification of Components in Diet Soft Drinks

2. a) R N and L N so R L or L R 2.


HPLC COLUMNS WILEY-VCH. Theory, Technology, and Practice. Uwe D. Neue with a contribution from M. Zoubair El Fallah

Gas Chromatography. Presented By Mr. Venkateswarlu Mpharm KTPC

Introduction to Gas Chromatography

DEFINITION CHROMATOGRAPHY

Chemistry Instrumental Analysis Lecture 26. Chem 4631

[S016. CHROMATOGRAPHY]

Chromatography and Functional Group Analysis

Basic Principles for Purification Using Supercritical Fluid Chromatography

CHAPTER 6 GAS CHROMATOGRAPHY

PDG.pdf G-20 CHROMATOGRAPHY 3 4 INTRODUCTION

High Performance Liquid Chromatography

High Performance Liquid Chromatography

Fall 2012 Due In Class Friday, Oct. 19. Complete the following on separate paper. Show your work and clearly identify your answers.

High Pressure/Performance Liquid Chromatography (HPLC)

Gas Chromatography. Introduction

Chromatography. Chromatography is a combination of two words; * Chromo Meaning color * Graphy representation of something on paper (writing)

Chromatography. What is Chromatography?

Adsorption Processes. Ali Ahmadpour Chemical Eng. Dept. Ferdowsi University of Mashhad

Chemistry Gas Chromatography: Separation of Volatile Organics

CHROMATOGRAPHIC SEPARATION TECHNIQUES SUPERCRITICAL FLUID CHROMATOGRAPHY

Chromatography. writing in color

Gas Chromatography. A schematic diagram of a gas chromatograph

Experiment Nine Thin Layer Chromatography

Open Column Chromatography, GC, TLC, and HPLC

Isolation & Purification of Proteoglycans (PGs) and Glycosaminoglycans (GAGs) PEG Trainee Lecture July 23, 2012

Chem 230, Fall, 2014 Homework Set # 3 Short Answer SOLUTIONS

Chemistry 11. Unit 3 The Physical Properties and Physical Changes of Substances

j 1 1 General Concepts

CHROMATOGRAPHY AND MASS SPECTROMETER

CHEM340 Tutorial 4: Chromatography

Chemistry Instrumental Analysis Lecture 27. Chem 4631

Speakers. Moderator. John V Hinshaw GC Dept. Dean CHROMacademy. Tony Taylor Technical Director CHROMacademy. Dave Walsh Editor In Chief LCGC Magazine

Chromatography and its applications

Liquid storage: Holds the solvent which is going to act as the mobile phase. Pump: Pushes the solvent through to the column at high pressure.

GAS CHROMATOGRAPHY. Mobile phase is a gas! Stationary phase could be anything but a gas

Protein separation and characterization

Adsorption (Ch 12) - mass transfer to an interface

CH 2252 Instrumental Methods of Analysis Unit V Gas Chromatography. M. Subramanian

Course CHEM Chromatography

Chromatography Lab # 4

Chapter 27: Gas Chromatography

SEPARATIONS ESSENTIALS IN MODERN HPLC. 2University of Bucharest, Bucharest, Romania

GC Instruments. GC Instruments - Sample Introduction

CHEMISTRY Unit 3, Area of Study 1: Chemical Analysis

Introduction to Capillary GC. Page 1. Agilent Restricted February 2, 2011

LIQUID CHROMATOGRAPHY

GC Instruments. GC Instruments - Columns

Chemistry Instrumental Analysis Lecture 28. Chem 4631

Ion Chromatography (IC)

Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 25: CHROMATOGRAPHIC METHODS AND CAPILLARY ELECTROPHORESIS

Transcription:

What is Chromatography? Chromatography is a physico-chemical process that belongs to fractionation methods same as distillation, crystallization or fractionated extraction. It is believed that the separation method in its modern form originated at the turn of the century from the work of Tswett to whom we attribute the terms chromatography and chromatogram The method was used for preparation and purification purposes until the development of sensitive detectors The detector signal, which is registered in continuum, leads to a chromatogram that indicates the variation of the composition of the eluting phase with time.

Chromatographic separations Sample is dissolved in a mobile phase (a gas, a liquid or a supercritical fluid) The mobile phase is forced through an immiscible stationary phase which is fixed in place in a column or on a solid surface. The two phases are chosen so that the components of the sample distribute themselves between the mobile and stationary phase to a varying degree.

(a)diagram showing the separation of a mixture of components A and B by column elution chromatography. (b)the output of the signal detector at the various stages of elution shown in (a).

Classification of chromatographic techniques Chromatographic techniques can be classified into three categories depending on the physical nature of the phases, the process used, or the physico-chemical phenomenon, which is at the basis of the Nernst distribution coefficient K, also defined as: We will take here the classification based on the nature of the phase present

1. Liquid-solid chromatography The mobile phase is a liquid and the stationary phase is a solid. This category, which is widely used, can be subdivided depending on the retention phenomenon into: Adsorption chromatography Ion chromatography Molecular exclusion chromatography

a. Adsorption chromatography The separation of organic compounds on a thin layer of silica gel or alumina with solvent as a mobile phase Solutes bond to the stationary phase because of physisorption or chemisorption interactions. The physico-chemical parameter involved is the coefficient of adsorption.

b. Ion chromatography The mobile phase in this type of chromatograph; is a buffered solution and the stationary phase consists of spherical µm diameter particles of a polymer The surface of the particles is modified chemically in order to generate ionic sites. These phases allow the exchange of their mobile counter ion, with ions of the same charge present in the sample. This separation relies on the coefficient of ionic distribution

c. Molecular exclusion chromatography The stationary phase is a material containing pores, the dimensions of which are chosen to separate the solutes present in the sample based on their molecular size. This can be considered as a molecular sieve allowing selective permeation. This technique is known as gel filtration or gel permeation, depending on the nature of th mobile phase, which is either aqueous or organic. The distribution coefficient in this technique is called the coefficient of diffusion.

2. Liquid-liquid chromatography (LLC) Stationary phase is a liquid immobilized in the column. It is important to distinguish between the inert support which only has a mechanical role and the stationary phase immobilized on the support Impregnation of a porous material with a liquid phase was used earlier but had the problem of bleeding In order to immobilize the stationary phase, it is preferable to fix it to a mechanical support using covalent bonds. The stationary phase still acts as a liquid and the separation process is based on the partition of the analyte between the two phases at their interface. The parameter involved in the separation mechanism is called the partition coefficient.

3. Gas-liquid chromatography (GLC) The mobile phase is a gas and the stationary phase is a liquid. The liquid can be immobilized by impregnation or bonded to a support, The partition coefficient K is also involved 4. Gas-solid chromatography (GSC) Stationary phase is a porous solid (such as graphite or silica gel) and the mobile phase is a gas. This type demonstrates very high performance in the analysis of gas mixtures or components that have a very low boiling point.

5. Supercritical fluid chromatography (SFC) The mobile phase is a fluid in its supercritical state, such as carbon dioxide at about 50 C and at more than 150 bars (15 MPa). The stationary phase can be a liquid or a solid. This approach combines the advantages of the LLC and GLC techniques

The Chromatogram It reveals, as a function of time, a parameter the depends on the instantaneous concentration of the solute as it exits the column The components entering the detector will be shown as a series of peaks that would be more or less resolved from one another as they rise from the baseline obtained in the absence of analyte. If the detector signal varies linearly with the concentration of analyte, the same variation will occur for the area under the peak in the chromatogram. A constituent is characterized by its retention time, t R, Retention time is defined by the time taken between the moment of injection into the chromatograph and the peak maximum recorded on the chromatogram.

In an ideal case, the retention time t R is independent of the quantity injected. A compound not retained will elute out of the column at time t M, called the void time or the dead time (sometimes designated by t o ). The separation is complete when as many peaks are seen returning to the baseline as there are components in the mixture. In quantitative analysis, it suffices to separate only the components that need to be measured. Identification by chromatography is arbitrary. For a better confirmation, another identification method has to go along with thechromatography When t M = t R ; there would be no separation, why? All components will move st the same rate through the colum

a. Retention time b. Distribution of the peak c. Significance of the three basic parameters and features of a Gaussian distribution d. Example of a real chromatogram

Definition of plate height H =

The Theoretical Plate Model Many theories have been suggested to explain the mechanism of migration and separation of analytes in the column. The oldest one, called the theoretical plate model, corresponds to an approach now considered obsolete but which nevertheless leads to relations and definitions that are universal in their use and are still employed today. In this model, each analyte is considered to be moving progressively through the column in a sequence of distinct steps, although the process of chromatography is a dynamic and continuous phenomenon. Each step corresponds to a new equilibrium of the entire column. In liquid-solid chromatography, for example, the elementary process is described as a cycle of adsorption/desorption.

Column Efficiency As the analyte migrates through the column, it occupies an increasing area This linear dispersion σ L, measured by the variance σ L increases with the distance of migration. When this distance is equal to L, the column length, the variance will be: σ 2 L= HxL where H is the same as the value for the height equivalent to one theoretical plate Since N = L/H N = L 2 / σ 2 L N here is called theoretical efficiency of the compound. Thus, N = t 2 R/ σ 2 The more appropriate equation for N is N = 5.54 t 2 R /w2 1/2

Dispersion of a solute in a column and its translation into a chromatogram Isochronic image of the concentration of an eluted compound at a particular instant. Variation of the concentration at the outlet of the column as a function of time. On the chromatogram, σ Represents the peak width At 60.6% of the height

Effective plate number If the performance of different columns has to be compared for a given compound, more realistic values are obtained by replacing the total retention times t R, by the adjusted retention times t R t R does not take into account the void time t M spent by the compound in the mobile phase. The mathematical relationships:

Retention parameters In chromatography, three volumes are usually considered. 1. Volume of the mobile phase in the column (dead volum The volume of the mobile phase in the column (called the dead volume) V M corresponds to the accessible interstitial volume. It can be determined from the chromatogram provided a solute not retained by the stationary phase is used. V M can be expressed as a function of t M and flow rate F: V M = t M x F

2. Volume of the stationary phase, V s. This volume does not appear on the chromatogram V s can be determined by subtracting the volume of the mobile phase from the total volume inside the column. 3. Retention volume, V R The retention volume V R of each analyte represents the volume of mobile phase necessary to cause its migration throughout the column. On the chromatogram, the retention volume corresponds to the volume of mobile phase that has passed through the column from the time of injection to the peak maximum. V R = t R x F

Retention factor k (historically called capacity factor, K ) When a compound is injected onto a column, its total mass m T is divided in two quantities: m M, the mass in the mobile phase and m s, the mass in the stationary phase. The values of these quantities are dependent on M T and K but their ratio, the retention factor, is constant: The factor k, which is independent of the flow rate and length of the column, can vary with experimental conditions. k is the most important parameter in chromatography for determining the behavior of columns. The value of k should not be too high otherwise the time of analysis is unduly elongated.

Experimental determination of the retention factor, k The mobile phase progressively transports the analyte towards the end of the column It is assumed that the ratio of the retention volume V R to the dead volume V M is identical to the ratio which exists between the total mass of the compound and the mass dissolved in the dead volume. Consequently:

Using the equations: V M = t M x F Then, t R =t M ( 1 + k) and V R = t R x F Therefore, the value of k is accessible from the chromatogram and can be obtained using the following equation

Separation factor between two solutes The separation factor, α, allows the comparison of two adjacent solutes 1 and 2 present in the same chromatogram Thus, the separation factor is given by the equation:

Resolution factor between two peaks To quantify the separation between two peaks, the resolution factor R is used and can be obtained from the chromatogram

The van Deemter equation in gas chromatography When the characteristics of a separation were expressed previously, the speed of the mobile phase in the column did not appear. However, the speed has to affect the progression of the solutes, hence their dispersion within the column, and must have an effect on the quality of the analysis. These kinetic considerations are collected in a famous equation proposed by van Deemter. The simplified form of this equation is given below

Van Deemter Equation The three experimental parameters A, B and C are related to column parameters and also to experimental conditions. If H is expressed in cm, A will be expressed in cm, B in cm cm 2 /s and C in s (where velocity is measured in cm/s). The function is a hyperbolic function that goes through a minimum (H min ) when

Van Deemter plot for gas phase chromatography showing domains for A, B and C.

Van Deemter equation which has been expanded to cover both gas and liquid chromqtography The equation shows that there is an optimum flow rate for each separation and that this does indeed correspond to the minimum on the curve represented by equation The loss in efficiency that occurs when the velocity is increased represents what occurs when trying to rush the chromatographic separation by increasing the flow rate of the mobile phase. However, it is hard to predict the loss in efficiency that occurs when the flow is too slow. How?

Term A, packing term (Eddy diffusion) The term A is related to the flow profile of the mobile phase as it traverses the stationary phase. The size of the stationary phase particles, their dimensional distribution, and the uniformity of the packing are responsible for a preferential path and add mainly to the improper exchange of solute between the two phases. This phenomenon is the result of Eddy diffusion or turbulent diffusion, considered to be non-important in liquid chromatography or absent by definition in capillary columns, and WCOT (wall coated open tubular) in gas phase chromatography

Term B, diffusion coefficient in the mobile phase The term B is related to the longitudinal molecular diffusion in the column. It is especially important when the mobile phase is a gas. This term is a consequence of entropy, telling us that a system will tend towards the maximum degrees of freedom as demonstrated by a drop of ink that diffuses after falling into a glass of water. Hence, if the flow rate is too slow, compounds being separated will mix faster than they will migrate. This is why one must never interrupt the separation process, even momentarily.

Term C, mass transfer coefficient The coefficient C is related to the resistance to mass transfer between the two phases It becomes important when the flow rate is too high for equilibrium to be obtained. Local turbulence within the mobile phase and concentration gradients slow down the equilibrium process (Cs = Cm). The diffusion of solute between the phases is not instantaneous, hence the solute will be in a non-equilibrium process.

Optimization of a chromatographic analysis Because analytical chromatography is used inherently in quantitative analysis, it becomes crucial to precisely measure the areas of the peak. Therefore, the substances to be determined must be well separated. In order to achieve this, the analysis has to be optimized using all the resources of the instrumentation and, when possible, software that can simulate the results of temperature modifications, phases and other physical parameters. This optimization process requires that the chromatographic process is well understood.