Analysis - HPLC A.136. Primesep 5 µm columns B.136

Similar documents
HICHROM. Chromatography Columns and Supplies. LC COLUMNS SIELC Primesep. Catalogue 9. Hichrom Limited

The column name corresponds to ph value of the mobile phase where acid residue on the column switches from ionize form to neutral one.

Comparison of different aqueous mobile phase HPLC techniques

Hints for Strong Ion Exchange Resins

Fast Separation of Vastly Different Compounds by Isocratic HPLC

LC Columns with Liquid Separation Cell Technology

8. Methods in Developing Mobile Phase Condition for C18 Column

Shodex TM ODP2 HP series columns

Mechanisms of retention in HPLC

Method Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples

Primesep TM. Solving Problems of Pharmaceutical HPLC Analysis. Creating New Dimensions in the World of Chromatography.

Liquid Chromatography

penta-hilic UHPLC COLUMNS

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

Rapid Post-Blast Inorganic Explosive Analysis by Suppressed Ion Chromatography

Acclaim Mixed-Mode WCX-1

Packings for HPLC. Packings for HPLC

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules

SHARC Separation separation Technology. LC Column with Hydrogen Bonding Based Separation. 65 E. Palatine Rd., Suite 221. SIELC Technologies, Inc.

Evolution of Mixed-Mode

EVOLUTE WCX Columns for Solid Phase Extraction of Quaternary Amines and Strongly Basic Compounds from Aqueous Samples

penta-hilic UHPLC COLUMNS

The Theory of HPLC. Ion Pair Chromatography

groups I and II cations, amines, divalent transition metals

LC and LC/MS Column Selection Flow Chart

Inertsil ODS-EP Technical Information

Chromatography. Gas Chromatography

for Acclaim Mixed-Mode WCX-1

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

for Acclaim Trinity TM P1

High Performance Liquid Chromatography

High Performance Liquid Chromatography

for Acclaim Mixed-Mode HILIC-1 Column

SHARC Separation separation Technology. LC Column with Hydrogen Bonding Based Separation. 65 E. Palatine Rd., Suite 221. SIELC Technologies, Inc.

It s hot! ZIC -chilic

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SeQuant ZIC-HILIC. Catalogue 9. Hichrom Limited

Too Polar for Reversed Phase What Do You Do?

Primesep TM. Columns Methods Applications. Creating New Dimensions in the World of Chromatography. 1

Cation Exchange HPLC Columns

High Performance Liquid Chromatography

Reversed Phase Solvents

4. Ion chromatography (IC) 4.1. Educational aims and objectives

Ion Chromatography. Anion Exchange. Chromatography Ion Exchange Theory. Dr. Shulamit Levin

Chiral Columns for enantiomer separation by HPLC

Handling Products. Sumitomo Chemical Co., Ltd. SUMICHIRAL ~192

Chapter 23 Introduction to Analytical Separations

LC Technical Information

Silanol. Groups Liquid Chromatography

ProPac WCX-10 Columns

Dilution(*) Chromatography

QUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE. C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3

1. Ion exchange chromatography

Chromatography- Separation of mixtures CHEM 212. What is solvent extraction and what is it commonly used for?

Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 25: CHROMATOGRAPHIC METHODS AND CAPILLARY ELECTROPHORESIS

HILIC Method Development in a Few Simple Steps

ION PAIRING REAGENTS AND BUFFERS

Zirconia-Based Phases as a Powerful Complement to Silica-Based Phases for LC and LC-MS under Non-extreme Mobile Phase Conditions

Dionex IonPac AS28-Fast-4µm column

Optimizing GPC Separations

Chiral Flash Columns

Ch.28 HPLC. Basic types of Liquid Chromatography Partition (LLC) Adsorption (LSC) Ion Exchange (IC) Size Exclusion (SEC or Gel Chromatography)

Fluophase and Fluofix Columns

HPLC Background Chem 250 F 2008 Page 1 of 24

IC Columns Introduction

Method Development with ZirChrom's Ion Exchange Phases

Yuhui Yang, An Trinh, Michael Ye, and Tom Henderson 595 North Harrison Road, Bellefonte, PA T HKB

Ion Chromatography (IC)

Acclaim Mixed-Mode WAX-1 Columns

DEVELOPMENT OF HPLC METHOD FOR ANALYSIS OF NITRITE AND NITRATE IN VEGETABLE

Saccharides and Organic Acids

Ion Chromatography *

Chromatographic Analysis

Chem 230, Fall, 2014 Homework Set # 3 Short Answer SOLUTIONS

C18 Column. Care & Use Sheet

Instrumental Chemical Analysis

Protein separation and characterization

Reversed-Phase Method Development Guide

Analyze Nucleotides, Nucleosides, Purine, and Pyrimidine Bases Simultaneously with the Ultra IBD Column

Your Reversed Phase Method

Novel LC/MS-Compatible Stationary Phase with Polar Selectivity

column If you would like a subscription, or more information, please contact your nearest Waters Office.

Chemistry Instrumental Analysis Lecture 28. Chem 4631

STUDY OF LOADABILITY AND SELECTIVITY OF PHARMACEUTICAL COMPOUNDS ON RPLC COLUMNS

ProntoSIL C18-EPS Reversed-Phase HPLC Columns

InertSustainSwift C8

HPLC. GRATE Chromatography Lab Course. Dr. Johannes Ranke. September 2003

columns IonPac SCS 1 Silica Cation Separator

HPLC Column Classification

Application of Bio-SPME for the Enrichment of Illicit Phenethylamine and Cathinone Compounds from Biological Samples

Liquid storage: Holds the solvent which is going to act as the mobile phase. Pump: Pushes the solvent through to the column at high pressure.

Agilent 1290 Infinity Quaternary LC Stepwise Transfer to Methods with MS-Compatible Mobile Phases

Method Development Kits

The Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times

Zirconia: the Ideal Substrate for Ion-Exchange LC and LC-MS

Reversed Phase Chromatography: Mobile phase Considerations

Method Development Guide. A Step by Step Approach to Developing Reproducible HILIC Methods + + ACE HILIC Method Development Guide

No.106. Aqueous SEC Columns for Analysis of Cationic Polymers: TSKgel PWXL-CP Series. Contents. Page

INSTRUCTION MANUAL FOR CHIRALPAK ZWIX(+) and CHIRALPAK ZWIX(-)

Thermo Scientific Syncronis HPLC Columns. Remarkable separations guaranteed time after time

Transcription:

Primesep 5 µm columns Primesep columns feature double functionality of the bonding i.e : alkyl chain with anionic or cationic group, chelating group. This feature creates unique selectivities when using an appropriate mobile phase. Columns operate in several acidic environments : º Primesep A (ionized in all working ph) The most acidic sorbent. Strongly retains weak bases and amino compounds and presents a unique selectivity with neutral compounds. Ion exchange and hydrophobic mechanism for separation of neurotransmitters on Primesep 200 column Column : 150 x 3.2 mm Eluent : H 2 O/meCN/TFA - 90/10/0.1 Flow rate : 0.5 ml /min Detector : UV 210 nm º Primesep 100 (~ 50% of embedded acidic groups ionized at transition ph 1) The most universal column of the Primesep range. It can be used for the separation of basic, acidic, neutral or zwitterionic compounds. Acids are separated due to ion exclusion. Bases being controlled by cationic exchange. º Primesep 200 (~ 50% of embedded acidic groups ionized at transition ph 2) Less acidic than Primesep 100, it is more suited to reverse phase mode. Selectivity is directly related to the use of less acidic mobile phases in order to favour basic compound elution. Description Primesep A Primesep 100 Primesep 200 250 x 4.6 mm A-46.250.0510 100-46.250.0510 200-46.250.0510 150 x 4.6 mm A-46.150.0510 100-46.150.0510 200-46.150.0510 50 x 4.6 mm A-46.050.0510 100-46.050.0510 200-46.050.0510 250 x 3.2 mm A-32.250.0510 100-32.250.0510 200-32.250.0510 150 x 3.2 mm A-32.150.0510 100-32.150.0510 200-32.150.0510 50 x 3.2 mm A-32.050.0510 100-32.050.0510 200-32.050.0510 250 x 2.1 mm A-21.250.0510 100-21.250.0510 200-21.250.0510 150 x 2.1 mm A-21.150.0510 100-21.150.0510 200-21.150.0510 50 x 2.1 mm A-21.050.0510 100-21.050.0510 200-21.050.0510 150 x 1.0 mm A-10.150.0510 100-10.150.0510 200-10.150.0510 50 x 1.0 mm A-10.050.0510 100-10.050.0510 200-10.050.0510 Preparative columns 250 x 22 mm A-220.250.0510 100-220.250.0510 200-220.250.0510 150 x 22 mm A-220.150.0510 100-220.150.0510 200-220.150.0510 Bonding aspect under ph transition value of embedded acidic groups A.136 Bonding aspect above ph transition value of embedded acidic groups B.136

Primesep B 5 µm columns All B-type columns provide at least two main interactions with analytes : the reverse-phase interaction and the anion-exchange interaction. Neutral analytes are retained by reverse phase interaction. The presence of the charged group in the alkyl chain provides additional selectivity uncommon for typical reverse-phase columns. Acidic analytes can be retained by both anion-exchange and reverse-phase mechanisms. Columns are in three basic environments : º Primesep B Primesep B is a strong basic column. The recommended ph range is from 1.5 to 4 created by the addition of trifluoroacetic, phosphoric, perchloric, or formic acid to the mobile phase. º Primesep B2 Primesep B2 is a weak basic column. It also has carboxylic acidic functional group.when mobile phase ph is below 5, acidic groups are not ionized and B2 column surface becomes positively charged. This dual chemistry offers an extended ph range from 0.5 to 7, suitable for ammonium acetate and ammonium formate buffered mobile phases. º Primesep B4 Primesep B4 is a reverse phase stationary phase with a short length modification that exhibits basic functionality. Separation of acidic compounds is via ion exchange and ion exclusion mechanisms facilitate the retention of hydrophobic base. This stationary phase is also relevant for acidic and basic surfactant analysis. ph stability 2 -to- 4.5 Both a cationic drug and chloride anion analyzed with single isocratic method Primesep B : Flow rate : Detector : Eluent : 150 x 3.2 mm 1.0 ml /min ELSD, UV 210 nm Water/MeCN/AmAc-40/60/0.2 Description Primesep B Primesep B2 Primesep B4 250 x 4.6 mm B-46.250.0510 B2-46.250.0510 B4-46.250.0510 150 x 4.6 mm B-46.150.0510 B2-46.150.0510 B4-46.150.0510 50 x 4.6 mm B-46.050.0510 B2-46.050.0510 B4-46.050.0510 250 x 3.2 mm B-32.250.0510 B2-32.250.0510 B4-32.250.0510 150 x 3.2 mm B-32.150.0510 B2-32.150.0510 B4-32.150.0510 50 x 3.2 mm B-32.050.0510 B2-32.050.0510 B4-32.050.0510 250 x 2.1 mm A.137 B-21.250.0510 B2-21.250.0510 B4-21.250.0510 150 x 2.1 mm B-21.150.0510 B2-21.150.0510 B4-21.150.0510 50 x 2.1 mm B-21.050.0510 B2-21.050.0510 B4-21.050.0510 150 x 1.0 mm B-10.150.0510 B2-10.150.0510 B4-10.150.0510 50 x 1.0 mm B-10.050.0510 B2-10.050.0510 B4-10.050.0510 Semi preparative columns 250 x 22 mm B-220.250.0510 B2-220.250.0510 B4-220.250.0510 150 x 22 mm B-220.150.0510 B2-220.150.0510 B4-220.150.0510 Primesep B - Primesep B2 Chemistry Schematic.com - Please contact your local distributor B.137

Primesep column comparison Primesep columns differ in the degree they retain ionic compounds. Neutral compounds display similar retention on all Primesep columns. Primesep A, 100, 200 are cation exchange columns with different strengths of embedded functional groups. Primesep B and B2 are anion exchange columns. Primesep is a silica based material which is stable in all organic solvents and water at ph range from 1.0 to 7.5. Primesep columns comparison 5µm, 150 x 4.6 mm column Flow rate : 1,0 ml /min Detector : UV 210 nm Eluent : Water/MeCN/TFA-60/40/0.1 Primesep A Primesep 100 Primesep 200 Primesep B Primesep B2 Common C18 A.138 B.138

Primesep C 5 µm columns Primesep C columns are the latest addition to the range which combine reverse-phase, cation exchange, and complex-formation properties in interaction with amines, sulfonium, phosphonium and metal ions. This column has a unique unparallelled selectivity for separating complex mixtures. The ph working range for these columns is from 1 to 7, but their complex formation and cation-exchange properties are substantially suppressed at a ph below 3 and therefore to facilitate the complex formation, the ph of the mobile phase should remain in the range of 3-7. The degree of complex formation can be adjusted by selecting the ph of the mobile phase. º Complex Interaction Schematic chemistry Description Primesep C Analytical Columns 250 x 4.6 mm C-46.250.0510 150 x 4.6 mm C-46.150.0510 50 x 4.6 mm C-46.050.0510 250 x 3.2 mm C-32.250.0510 150 x 3.2 mm C-32.150.0510 50 x 3.2 mm C-32.050.0510 250 x 2.1 mm C-21.250.0510 150 x 2.1 mm C-21.150.0510 50 x 2.1 mm C-21.050.0510 150 x 1.0 mm C-10.150.0510 50 x 1.0 mm C-10.050.0510 Quaternary amines separated on Primesep C Primesep C : 150 x 4.6 mm x 5 µm Eluent : MeCN/H 2 O-15/85 TEA acetate 20 mm ph 5.0 Flow rate : 1.0 ml /min Detector : ELSD, T 35 C) Injection : 5 mc Sample : 0.6 mg /ml each analyte Semi preparative columns 250 x 22 mm C-220.250.0510 150 x 22 mm C-220.150.0510 A.139.com - Please contact your local distributor B.139

Primesep P 5 µm columns Primesep P columns provide three unique interactions with analytes. º Reverse phase interaction º p-p interaction º Strong cation exchange interaction Depending on analyte properties, one, two, or all three interactions can be applied to the separation. This stationary phase facilitates the separation of structural isomers of aromatic compounds. Additional p-p interaction creates a difference in the bind state for structural isomers and often resolves critical pairs of compounds. The degree of p-p interaction can be adjusted by varying the amount of acetonitrile in the mobile phase. When methanol is used as an organic modifier, the highest degree of aromatic interaction can be achieved. Chemistry Schematic Description Primesep P 250 x 4.6 mm P-46.250.0510 150 x 4.6 mm P-46.150.0510 50 x 4.6 mm P-46.050.0510 250 x 3.2 mm P-32.250.0510 150 x 3.2 mm P-32.150.0510 50 x 3.2 mm P-32.050.0510 250 x 2.1 mm P-21.250.0510 150 x 2.1 mm P-21.150.0510 50 x 2.1 mm P-21.050.0510 150 x 1.0 mm P-10.150.0510 50 x 1.0 mm P-10.050.0510 Preparative columns 250 x 22 mm P-220.250.0510 150 x 22 mm P-220.150.0510 A.140 B.140