Pig IgG ELISA. Cat. No. KT-516 K-ASSAY. For the quantitative determination of IgG in pig biological samples. For Research Use Only. 1 Rev.

Similar documents
Rat Liver Fatty Acid Binding Protein (L-FABP) ELISA

Dog IgM ELISA. Cat. No. KT-458 K-ASSAY. For the quantitative determination of IgM in dog biological samples. For Research Use Only. 1 Rev.

Dog NGAL ELISA. For the quantitative determination of NGAL (Lipocalin-2) in dog biological samples. Cat. No. KT-546. For Research Use Only.

KAMIYA BIOMEDICAL COMPANY. Cat IgE ELISA. For the quantitative determination of IgE in cat biological samples. Cat. No. KT-394. For Research Use Only.

Mouse IgG2B ELISA. Cat. No. KT-405 K-ASSAY. For the quantitative determination of IgG2B in mouse biological samples. For Research Use Only.

Cat IgA ELISA. Cat. No. KT-755 K-ASSAY KAMIYA BIOMEDICAL COMPANY. For the quantitative determination of IgA in cat biological samples

Human Leptin ELISA. Cat. No. KT-1120 K-ASSAY. For the quantitative determination of leptin in human biological samples. For research use only.

Cat Serum Amyloid A (SAA) ELISA

Mouse IgE ELISA. Cat. No. KT-401 K-ASSAY. For the quantitative determination of IgE in mouse biological samples. For Research Use Only.

Mouse Lipocalin-2/NGAL ELISA

Human Alpha 1-Anti- Chymotrypsin ELISA

Rat Alpha Glutathione S- Transferase ELISA

IgG (Cat) ELISA Kit. Catalog Number KA assay Version: 01. Intend for research use only.

Horse Serum Amyloid A ELISA

Human Lipocalin-2/NGAL ELISA

LCN2 (Dog) ELISA Kit. Catalog Number KA assay Version: 01. Intend for research use only.

Rat Glutathione S-Transferase Yb1 (GST Yb1) ELISA

Human Lactoferrin ELISA

Mouse Myeloperoxidase ELISA

Guinea Pig Complement C3 ELISA

Mouse Ferritin ELISA

Human Myeloperoxidase ELISA

Human Beta 2-Microglobulin ELISA

Dog Complement C3 ELISA

IgG (Rabbit) ELISA Kit

Mouse Complement C3 ELISA

Pig Microalbumin ELISA

Rat Alpha-1 Acid Glycoprotein ELISA

IgG (Bovine) ELISA Kit

IgE (Rat) ELISA Kit. Catalog Number KA assays Version: 05. Intended for research use only.

IgE (Dog) ELISA Kit. Catalog Number KA assays Version: 05. Intended for research use only.

Mouse Ferritin ELISA

Rat Microalbumin ELISA

Rabbit IgA ELISA Kit

Mouse Transferrin ELISA

IgA (Guinea Pig) ELISA Kit

IgA ELISA. For the quantitative determination of IgA in human serum and plasma. For Research Use Only. Not for Use in Diagnostic Procedures.

Mouse IgE ELISA. For the quantitative determination of IgE in mouse serum or plasma. For Research use Only. Not For Use In Diagnostic Procedures.

IgD ELISA. For the quantitative determination of IgD in Human Sera. Please See Appendix A for Reference Serum Information

Dog Microalbumin ELISA

IgA ELISA. For the quantitative determination of IgA in human serum and plasma. Please see Appendix A for Reference Serum Information

For the quantitative determination of IgE in equine serum and plasma. For Research Use Only. Not For Use In Diagnostic Procedures.

Cystatin C ELISA. For the quantitative determination of cystatin C in human biological samples.

Prealbumin (Mouse) ELISA KitI

TF (Bovine) ELISA Kit

IgD ELISA. For the quantitative determination of IgD in Human serum and plasma. Please See Appendix A for Reference Serum Information

The Human IgD ELISA KIT is a highly sensitive two-site enzyme linked immunoassay (ELISA) for measuring IgD in Human Biological Samples.

IgM (Canine) ELISA. For the quantitative determination of IgM in canine serum and plasma. For Research Use Only. Not For Use In Diagnostic Procedures.

IgG (Canine) ELISA. Please see Appendix A for Reference Serum information. For Research Use Only. Not For Use In Diagnostic Procedures.

Mouse KIM-1 ELISA. For the quantitative determination of Kidney Injury Molecule in mouse serum, plasma, or urine.

Casein (Bovine) ELISA Kit

Mouse Retinol Binding Protein 4 ELISA

Cat Haptoglobin ELISA

C3 (Mouse) ELISA Kit. Catalog Number KA assays Version: 15. Intended for research use only.

Rat Ferritin ELISA. For the determination of ferritin in serum and plasma of rats. For Research Use Only. Not For Use In Diagnostic Procedures.

KIM-1 ELISA. For the quantitative determination of Kidney Injury Molecule in various biological samples.

Canine Lipocalin-2 (NGAL) ELISA KIT

HUMAN MYELOPEROXIDASE

Mouse Myeloperoxidase ELISA

Mouse Haptoglobin ELISA

CANINE COMPLEMENT FACTOR 3 (C3) ELISA

Rat Beta-2 Microglobulin ELISA

Dog High-Sensitive CRP ELISA

Rat High-Sensitive CRP ELISA

Hp (Rat) ELISA Kit. Catalog Number KA assays Version: 01. Intended for research use only.

Pig High-Sensitive CRP ELISA

HP (Rabbit) ELISA Kit

Haptoglobin (Horse) ELISA Kit

Crp (Mouse) ELISA Kit

CRP (Pig) ELISA Kit. Catalog Number KA assay Version: 03. Intended for research use only.

Mouse C-Reactive Protein ELISA

Rabbit C-Reactive Protein ELISA

Haptoglobin ELISA. For the quantitative determination of haptoglobin in human serum and plasma.

Porcine C-Reactive Protein ELISA

ab IgE Cat ELISA Kit

ab IgA Cat ELISA Kit

ab Ferritin (FTL) Rat ELISA Kit

ab C Reactive Protein (PTX1) Dog ELISA Kit

ab IgE Mouse ELISA Kit

ab Pig CRP ELISA Kit

ab IgA Pig ELISA Kit

ab Bovine IgG ELISA Kit

ab Retinol Binding Protein (RBP) Dog ELISA Kit

ab Mouse IgE ELISA Kit

Mouse Glutathione S Transferase Alpha 1 (GSTa1)

ab Dog NGAL ELISA Kit

ab IgG Mouse ELISA Kit

ab CRP Cat ELISA Kit

Pig Vascular Endothelial Cell Growth Factor A (VEGF-A) ELISA

Human Superoxide Dismutase 2 (SOD2) ELISA

RUO. DRG Amyloid beta Auto-Ab (serum) As of 14 Dec rm (Vers. 1.1)

Human rheumatoid factor (RF) antibody (IgM) ELISA Kit

Human vitamin A (VA) ELISA

Human anti-ganglioside IgG antibody (GM1-IgG) ELISA Kit

Hepatitis B virus IgM ELISA Kit

Chlamydia Trachomatis IgG ELISA kit

CA125 (Human) ELISA Kit

Mouse Platelet Factor 4 (PF4) ELISA

Human anti-myelin associated glycoprotein antibody (MAG) Ab ELISA Kit

Paraquat ELISA Kit. Catalog Number KA assays Version: 17. Intended for research use only.

Transcription:

K-ASSAY Pig IgG ELISA For the quantitative determination of IgG in pig biological samples Cat. No. KT-516 For Research Use Only. 1 Rev. 123109

K-ASSAY PRODUCT INFORMATION Pig IgG ELISA Cat. No. KT-516 INTENDED USE The Pig IgG ELISA is a highly sensitive two-site enzyme-linked immunoassay (ELISA) for the quantitative determination of IgG in pig biological samples. For research use only. This kit has minimum reactivity against human IgG. PRINCIPLE The principle of the double antibody sandwich ELISA is represented in Figure 1. In this assay the IgG present in samples reacts with the anti-igg antibodies which have been adsorbed to the surface of polystyrene microtiter wells. After the removal of unbound proteins by washing, anti-igg antibodies conjugated with horseradish peroxidase (HRP), are added. These enzyme-labeled antibodies form complexes with the previously bound IgG. Following another washing step, the enzyme bound to the immunosorbent is assayed by the addition of a chromogenic substrate, 3,3,5,5 - tetramethylbenzidine (TMB). The quantity of bound enzyme varies directly with the concentration of IgG in the sample tested; thus, the absorbance, at 450 nm, is a measure of the concentration of IgG in the test sample. The quantity of IgG in the test sample can be interpolated from the calibration curve constructed from the calibrators, and corrected for sample dilution. Figure 1. Anti-IgG Antibody Bound To Solid Phase Calibrators and Samples Added IgG * Anti-IgG Complexes Formed Unbound Sample Proteins Removed Anti-IgG-HRP Conjugate Added Anti-IgG-HRP * IgG * Anti-IgG Complexes Formed Unbound Anti-IgG-HRP Removed TMB Substrate Added Determine Bound Enzyme Activity COMPONENTS 1. Diluent Concentrate One bottle containing 50 ml of a 5X concentrated diluent running buffer. 2. Wash Solution Concentrate One bottle containing 50 ml of a 20X concentrated wash solution. 3. Enzyme-Antibody Conjugate Concentrate One vial containing 150 µl of a 100X concentrated affinity-purified anti-pig IgG antibody conjugated with HRP in stabilizing buffer. 2 Rev. 123109

4. TMB Substrate Solution One vial containing 12 ml of TMB and hydrogen peroxide in citric acid buffer at ph 3.3. 5. Stop Solution One vial containing 12 ml of 0.3 M sulfuric acid. WARNING: Avoid contact with skin. 6. Microtiter Plate Twelve removable eight-well strips in well holder frame. Wells are coated with affinity-purified anti-pig IgG. 7. Pig IgG Calibrator One vial containing Pig IgG Calibrator. MATERIALS REQUIRED BUT NOT PROVIDED Precision pipettes (2 µl to 200 µl) for making and dispensing dilutions Test tubes Microplate washer/aspirator Distilled or de-ionized H 2 O Microplate reader Assorted glassware for the preparation of reagents and buffer solutions Timer Vortex mixer PRECAUTIONS 1. Read the instructions carefully before beginning the assay. 2. This kit is for research use only. 3. Great care has been taken to ensure the quality and reliability of this product. However, it is possible that in certain cases, unusual results may be obtained due to high levels of interfering factors. 4. No additives or preservatives are necessary to maintain the integrity of the specimen. Avoid azide contamination. 5. Azide and thimerosal at concentrations higher than 0.1% inhibit the enzyme reaction. 6. Other precautions: Do not interchange kit components from different lots. Do not use kit components beyond the expiration date. Protect reagents from direct sunlight. Do not pipette by mouth. Do not eat, drink, smoke or apply cosmetics where reagents are used. Avoid all contact with the reagents by using gloves. Stop solution contains diluted sulfuric acid. Irritation to eyes and skin is possible. Flush with water after contact. REAGENT PREPARATION 1. Diluent Concentrate The Diluent solution supplied is a 5X concentrate and must be diluted 1:5 with distilled or de-ionized water. 2. Wash Solution Concentrate The Wash Solution supplied is a 20X concentrate and must be diluted 1:20 with distilled or de-ionized water. Crystal formation in the concentrate is not uncommon when storage temperatures are low. Warming of the concentrate to 30-35 C before dilution can dissolve crystals. 3. Enzyme-Antibody Conjugate Concentrate Calculate the required amount of working conjugate solution for each microtiter plate test strip by adding 10 µl Enzyme-Antibody Conjugate to 990 µl of 1X Diluent for each test strip to be used for testing. Mix uniformly, but gently. Avoid foaming. 4. TMB Substrate Solution Ready to use as supplied. 5. Stop Solution Ready to use as supplied. 3 Rev. 123109

6. Microtiter Plate Ready to use as supplied. Unseal microtiter pouch and remove plate from pouch. Remove all strips and wells that will not be used in the assay and place back in pouch and re-seal along with desiccant. 7. Pig IgG Calibrator The calibrator is now at a concentration of 13.5 mg/ml. Pig IgG Calibrators need to be prepared immediately prior to use (see chart below). Mix well between each step. Avoid foaming. Calibrator Concentration Calibrator Volume (ng/ml) added to 1X Diluent Volume of 1X Diluent A 135,000 2 µl Pig IgG Calibrator 198 µl 7 1,000 5 µl Calibrator A 670 µl 6 500 300 µl Calibrator 7 300 µl 5 250 300 µl Calibrator 6 300 µl 4 125 300 µl Calibrator 5 300 µl 3 62.5 300 µl Calibrator 4 300 µl 2 31.25 300 µl Calibrator 3 300 µl 1 15.625 300 µl Calibrator 2 300 µl 0 0 600 µl STORAGE AND STABILITY 1. Complete Kit The expiration date for the kit is stated on the outer label. The recommended storage temperature is 4 C. Note: See long term storage recommendations below for the Pig IgG Calibrator. 2. Diluent The 5X Diluent Concentrate is stable until the expiration date. The 1X working solution is stable for at least one week from the date of preparation. Both solutions should be stored at 4 C. 3. Wash Solution The 20X Wash Solution Concentrate is stable until the expiration date. The 1X working solution is stable for at least one week from the date of preparation. Both solutions can be stored at room temperature (RT, 16-25 C) or at 4 C. 4. Enzyme-Antibody Conjugate Undiluted anti-igg-hrp conjugate should be stored at 4 C and diluted immediately prior to use. The working conjugate solution is stable for up to 8 hours. 5. TMB Substrate Solution The TMB Substrate Solution should be stored at 4 C and is stable until the expiration date. 6. Stop Solution The Stop Solution should be stored at 4 C and is stable until the expiration date. 7. Microtiter Plate Anti-pig IgG coated wells are stable until the expiration date, and should be stored at 4 C in the sealed foil pouch with desiccant pack. 8. Pig IgG Calibrator Long Term Storage: Upon receipt, aliquot the calibrator and store them frozen. They will be stable until expiration date. Short Term Storage: The calibrator is stable for up to 14 days at 4 C. The working calibrator solutions should be prepared immediately prior to use and are stable for up to 8 hours. INDICATIONS OF INSTABILITY If the test is performing correctly, the results observed with the calibrator solutions should be within 20% of the expected values. 4 Rev. 123109

SPECIMEN COLLECTION AND HANDLING Blood should be collected by venipuncture and the serum separated from the cells, after clot formation, by centrifugation. For plasma samples, blood should be collected into a container with an anticoagulant and then centrifuged. Care should be taken to minimize hemolysis, excessive hemolysis can impact your results. Assay immediately or aliquot and store samples at -20 C. Avoid repeated freezing/thawing. For any sample that might contain pathogens, care must be taken to prevent contact with open wounds. No additives or preservatives are necessary to maintain the integrity of the specimen. Avoid azide contamination. ASSAY PROTOCOL Dilution of Samples Due to the high sensitive nature of the assay each sample should be diluted before use for a normal assay. A 1:10,000 dilution of serum or plasma is appropriate for most samples. For absolute quantification of samples that yield results outside the range of the calibration curve, a lesser or greater dilution might be required. If unsure of sample level, a serial dilution with one or two representative samples before running the entire plate is highly recommended. To prepare a 1:10,000 dilution of sample, transfer 5 µl of sample to 495 µl of 1X Diluent. This gives you a 1:100 dilution. Mix thoroughly. Next, dilute the 1:100 samples by transferring 10 µl to 990 µl of 1X Diluent. You now have a 1:10,000 dilution of your sample. Mix thoroughly at each stage. Procedure Bring all reagents to RT before use. 1. Pipette 100 µl of Calibrator 0 (0.0 ng/ml) in duplicate Calibrator 1 (15.625 ng/ml) in duplicate Calibrator 2 (31.25 ng/ml) in duplicate Calibrator 3 (62.5 ng/ml) in duplicate Calibrator 4 (125 ng/ml) in duplicate Calibrator 5 (250 ng/ml) in duplicate Calibrator 6 (500 ng/ml) in duplicate Calibrator 7 (1,000 ng/ml) in duplicate 2. Pipette 100 µl of diluted sample (in duplicate) into pre-designated wells. 3. Incubate the Microtiter Plate at 22 C (RT) for thirty (30 ± 2) minutes. Keep plate covered and level during incubation. 4. Following incubation, aspirate the contents of the wells. 5. Completely fill each well with appropriately diluted Wash Solution and aspirate. Repeat three times, for a total of four washes. If washing manually: completely fill wells with diluted Wash Solution, invert the plate and pour/shake out the contents in a waste container. Follow this by sharply striking the wells on absorbent paper to remove residual Wash Solution. Repeat three times for a total of four washes. 6. Pipette 100 µl of appropriately diluted Enzyme-Antibody Conjugate to each well. Incubate at 22 C (RT) for thirty (30 ± 2) minutes. Keep plate covered in the dark and level during incubation. 7. Wash and blot the wells as described in Steps 4 and 5. 8. Pipette 100 µl of TMB Substrate Solution into each well. 9. Incubate in the dark at RT for precisely ten (10) minutes. 10. After ten minutes, add 100 µl of Stop Solution to each well. 11. Determine the absorbance at 450 nm of the contents of each well. Zero the plate reader to air. 5 Rev. 123109

The absorbance of the final reaction mixture can be measured up to 2 hours after the addition of the Stop Solution. However, good laboratory practice dictates that the measurement be made as soon as possible. RESULTS 1. Subtract the average background value from the test values for each sample. 2. Using the results observed for the calibrators construct a calibration curve. The appropriate curve fit is that of a fourparameter logistics curve, although a second order polynomial (quadratic) or other curve fits may also be used. 3. Interpolate test sample values from calibration curve. Correct for sample dilution factor to arrive at IgG concentration in original sample. PERFORMANCE CHARACTERISTICS In accord with good laboratory practice, the assays for specific IgG require meticulous quality control. Each laboratory should use routine quality control procedures to establish inter- and intra-assay precision and performance characteristics. LIMITATION OF THE PROCEDURE 1. Reliable and reproducible results will be obtained when the assay procedure is carried out with a complete understanding of the information contained in the package insert instructions and with adherence to good laboratory practice. 2. Factors that might affect the performance of the assay include proper instrument function, cleanliness of glassware, quality of distilled or de-ionized water, and accuracy of reagent and sample pipettings, washing technique, incubation time or temperature. FOR RESEARCH USE ONLY 12779 Gateway Drive, Seattle, WA 98168 Tel: (206) 575-8068 Fax: (206) 575-8094 Email: LifeScience@k-assay.com www.k-assay.com 6 Rev. 123109