Determination of Carbon d13c isotopic composition from DIC samples

Similar documents
δ 13 C of DIC and carbonate samples: comparison of traditional mass spectrometry methods with an infrared spectrometry method

Automated, intelligent sample preparation: Integration of the ESI prepfast Auto-dilution System with the Thermo Scientific icap 7400 ICP-OES

Determination of ultratrace elements in photoresist solvents using the Thermo Scientific icap TQs ICP-MS

Analysis of high matrix samples using argon gas dilution with the Thermo Scientific icap RQ ICP-MS

Thermo Scientific GasBench II

Thermo Scientific icap TQ ICP-MS: Typical limits of detection

Overcoming Interferences with the Thermo Scientific icap 7000 Plus Series ICP-OES

Simplified workflows for the Thermo Scientific icap TQ ICP-MS

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

A Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry

Total Elemental Analysis of Food Samples for Routine and Research Laboratories, using the Thermo Scientific icap RQ ICP-MS

Thermo Scientific icap RQ ICP-MS: Typical limits of detection

Key Words Nanoparticles, spicp-ms, ICP-MS, Qtegra ISDS Software, AF4-ICP-MS

Total elemental analysis of food samples for routine and research laboratories using the Thermo Scientific icap RQ ICP-MS

A Study of Stability, Robustness and Time Efficiency of a New HPLC and a New Tandem MS

Evaluation of a New HPLC, a New Tandem MS and a New Data Processing Software for General Clinical Use

Using a Reagent-Free ion chromatography system to monitor trace anion contamination in the extracts of electronic components

Accurate measurement of elemental impurities in metals and metal alloys using the Thermo Scientific icap TQ ICP-MS

of mass spectrometry

Advanced ICP-MS techniques for overcoming interferences in LA-ICP-MS bioimaging

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

Key Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery

Elemental Analysis: NCS characterization of paper

Nitrogen/Protein determination of infant food by the Thermo Scientific FlashSmart Elemental Analyzer using helium or argon as carrier gases

Expanded capabilities in ammonium and amine detection

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling

Automated and accurate component detection using reference mass spectra

The key to your laboratory s success

Insights Into the Nanoworld Analysis of Nanoparticles with ICP-MS

High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems

Analysis of trace elements in polymer samples to ensure compliance with WEEE-RoHS standards using the Thermo Scientific icap 7200 ICP-OES

A Strategy for an Unknown Screening Approach on Environmental Samples Using HRAM Mass Spectrometry

Characterization of Polymers and Plastics (pellets, powders and films) by the Thermo Scientific FLASH 2000 Elemental Analyzer

EA-IRMS: Fast and Precise Isotope Analysis of Liquids on a Delta V Isotope Ratio MS with a High Temperature Conversion Elemental Analyzer

SmartNotes. What is meant by the term interference?

Elemental Analysis: CHNS/O characterization of polymers and plastics

Determinations of Inorganic Anions and Organic Acids in Beverages Using Suppressed Conductivity and Charge Detection

Supported Liquid Extraction (SLE) Guide and FAQ s. User Guide

ARGUS VI. Static Vacuum Mass Spectrometer. Static Vacuum ARGUS VI. Multicollection Low Volume Precision

Determination of Tetrafluoroborate, Perchlorate, and Hexafluorophosphate in a Simulated Electrolyte Sample from Lithium Ion Battery Production

High-Speed Environmental Analysis Using the Agilent 7500cx with Integrated Sample Introduction System Discrete Sampling (ISIS DS)

Ideal and powerful solution

Fusion UV/Persulfate TOC Analyzer

Accurate and Precise Sulfur Analysis using the Thermo Scientific FlashSmart Elemental Analyzer

Finnigan TC/EA. High Temperature Conversion Elemental Analyzer

Mass Spectral Studies of Polypropylene Chromatographic Well Plates

Introduction to Fourier Transform Infrared Spectroscopy

Defining quality standards for the analysis of solid samples

Thermo Scientific ICP-MS solutions for the semiconductor industry. Maximize wafer yields with ultralow elemental detection in chemicals and materials

for XPS surface analysis

Fast methods for the determination of ibuprofen in drug products

Thermo Scientific ELEMENT GD PLUS Glow Discharge Mass Spectrometer. Defining quality standards for the analysis of solid samples

METHOD VALIDATION REPORT

High-Throughput LC-MS/MS Quantification of Estrone (E1) and Estradiol (E2) in Human Blood Plasma/Serum for Clinical Research Purposes

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

ProPac WCX-10 Columns

-xt. -xt SYSTEM. Specifications for PAL-xt Systems. Valid for PAL-xt System models only. Prep and Load Platform

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

Plasma-free Metanephrines Quantitation with Automated Online Sample Preparation and a Liquid Chromatography-Tandem Mass Spectrometry Method

Determination of BTEX in Cigarette Filter Fibers Using GC-MS with Automated Calibration

IRMS. perspective. Isotope Ratio Mass Spectrometry.

Tomorrow s quantitation with the TSQ Fortis mass spectrometer: quantitation of phenylephrine hydrochloride for QA/QC laboratories

LCTech GmbH Chromatographie

Determination of trace anions in concentrated hydrofluoric acid

Separation of heat stable amine salts in methyldiethanolamine (MDEA) solutions using high-pressure IC

Fusion UV/Persulfate TOC Analyzer

Sensitive HILIC UHPLC-UV determination of steviol glycoside natural sweeteners

HELIX SFT. Static Vacuum ARGUS VI HELIX SFT. Static Vacuum Mass Spectrometer Static Vacuum Mass Spectrometer

HELIX MC Plus. Static Vacuum. ARGUS VI Thermo Scientific HELIX MC Plus Static Vacuum Mass Spectrometer Static Vacuum Mass Spectrometer

Using cold vapor generation atomic absorption to determine mercury impurities in pharmaceutical products

Method for Nitrite determination on Low-Range Samples

Application Note #97 Alkalinity and Hardness by Potentiometric Titration Using TRIS Buffer

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

Measuring Ammonia in Water and Wastewater using the Thermo Scientific Orion Dual Star ph/ise Meter

Method Development for a Simple and Reliable Determination of PCBs in Mineral Insulating Oil by SPME-GC-ECD

Thermo Scientific FLASH HT Plus Elemental Analyzer for IRMS

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

New Multi-Collector Mass Spectrometry Data for Noble Gases Analysis

Automated determination of the uniformity of dosage in quinine sulfate tablets using a fiber optics autosampler

Level. Automate your processes Automate your lab Innovate with. sensing. EasyPREP. sample handler. Automated Sample Preparation.

USGS District Laboratory, Troy, NY Dissolved Inorganic Carbon Analysis Standard Operating Procedure

AppNote 5/2008. Automation of Sample Preparation Steps using a Robotic X-Y-Z Coordinate Autosampler with Software Control KEYWORDS ABSTRACT

Speed and flexibility

COMBI. Gaschromatography. GC / GC-MS sample injector grows with your needs

Accurate and Precise Automated Dilution and In-line Conductivity Measurement Using the AS-AP Autosampler Prior to Analysis by Ion Chromatography

all suspects Identify Thermo Scientific Extractables & Leachables Workflow Unknown impurity identification and quantification workflows for:

Total Organic Carbon Analysis of Solid Samples for Environmental and Quality Control Applications

Introduction to Fourier Transform Infrared Spectroscopy

Standard Operating Procedure for the Analysis of Dissolved Inorganic Carbon CCAL 21A.1

HR/AM Targeted Peptide Quantification on a Q Exactive MS: A Unique Combination of High Selectivity, High Sensitivity, and High Throughput

DI 3500 Discrete Aoalvzer

Rapid Quan/Qual Metabolic Stability Analysis with Online Oxidative Metabolism Synthesis

BECKMAN COULTER QbD1200 Total Organic Carbon Analyzer Critical Measurements Made Simple

Multiple Fragmentation Methods for Small Molecule Characterization on a Dual Pressure Linear Ion Trap Orbitrap Hybrid Mass Spectrometer

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

Analysis of noble metals at low levels in geological reference materials and ores

A novel high resolution accurate mass Orbitrap-based GC-MS platform for routine analysis of Short Chained Chlorinated Paraffins

Transcription:

APPLICATION NOTE 30367 Determination of Carbon d13c isotopic composition from DIC samples Authors Introduction Magda Mandic, Nils Stoebener, Luka Mandic, Danijela Šmajgl Thermo Fisher Scientific, Bremen, Germany Dissolved Inorganic Carbon (DIC) is a common term for dissolved CO2, H2CO3, HCO3- and CO32- in water and their relative contribution varies with different environmental conditions. Keywords Dissolved Inorganic Carbon (DIC), Infrared Spectrometer By measuring DIC and other hydrological and geophysical environmental parameters at a study site, redistribution of carbon among different Earth reservoirs can be investigated. Various applications, including paleoclimatic temperature changes, investigation of the origin of water, mineral digenesis, microbial activity in various media and many more require information on the isotopic composition of DIC to draw scientific conclusions. Goal To demonstrate the method for Dissolved Inorganic Carbon (DIC) analysis by using the Thermo Scientific Delta Ray Isotope Ratio Infrared Spectrometer with URI Connect. For many decades different instrumental methods involving different models of the Thermo Scientific Isotope Ratio Mass Spectrometer portfolio with Thermo Scientific Kiel IV Carbonate Device, or the continuous flow Thermo Scientific GasBench II System with the carbonate-option in conjunction with a CTC GC PAL or Combi PAL Autosampler, offered the scientifically required high precision and high throughput capabilities for these samples and applications.

The Thermo Scientific Delta Ray Isotope Ratio Infrared Spectrometer (IRIS) with the Universal Reference Interface (URI) Connect and the Teledyne CETAC ASX-7100 Autosampler (Figure 1) now extends the traditional offerings with a system that can be used in the laboratory or in the field and offers high precision and throughput capabilities. It employs optical spectroscopy for continuous measurement of isotope ratio values and concentration of carbon dioxide in ambient air, and also for analysis of discrete samples from vials, syringes, bags, or other user-provided sample containers. As part of the workflow, reference gas measurements are regularly measured at the same concentration as the sample to allow for automatic drift correction. Carrier Gas Sample Gas Sleeve Probe Figure 1. Thermo Scientific Delta Ray Isotope Ratio Infrared Spectrometer with URI Connect. The preparation of the samples for analysis on the Delta Ray IRIS is similar to the method previously mentioned for the Gas Bench II System. Samples are put into vials, flushed with carrier, and phosphoric acid is added. The resulting sample-acid reaction releases CO 2 gas, which is then introduced into the Delta Ray IRIS via the Variable Volume. With this workflow, more than 100 samples in vial can be analyzed per day with a d 13 C precision better than 0.1. URI connect with Teledyne CETAC ASX-7100 Autosampler For the analysis performed using the Teledyne CETAC ASX-7100 Autosampler, a dual probe is required (Figure 1). Samples are placed in 12 ml Labco Exetainer vials and then preflushed with carrier using the autosampler. The CO 2 gas released by the acid is flushed into the Variable Volume inside the URI Connect through the Nafi on based built-in water trap. For this step, carrier gas (usually CO 2 free air) is used to flush the gas from the vial in the autosampler into the Variable Volume with a maximum volume of 100 ml. A small amount of the sample is then used for automated determination of the CO 2 concentration present in the Variable Volume. The Thermo Scientific Qtegra Intelligent Scientific Data Solution (ISDS) Software then automatically adjusts any additional dilution of the sample to achieve the desired concentration (usually 400 ppm) in the analyzer. Figure 2. Dual probe of the Teledyne CETAC ASX-7100 Autosampler allowing carrier gas to enter at the bottom and to flush the vial headspace through the top feed into the Variable Volume of the URI Connect. Experimental setup Measurements were done with three Delta Ray IRIS operating in parallel. To confirm high accuracy and precision of the Delta Ray IRIS, three IAEA international standard materials were used (LSVEC, NBS 18 and NBS 19). LSVEC and NBS 19 were used as reference materials and NBS 18 was treated as the unknown. The Principle of Identical Treatment (IT) was applied in sample and standard preparation and measurement procedure as well as in the evaluation of the results. The NBS 18 sample material was measured in 20 replicates on each instrument while the reference material NBS 19 and LSVEC were measured in 2-3 replicates usually at the start, in the middle and at the end of the sequence. Sample preparation Samples of 200 to 300 μg were introduced into precleaned borosilicate vials, then caped and flushed with carrier gas for 3 minutes each. After flushing, samples were manually acidified using 300 µl of 43% phosphoric acid (H 3 PO 4 ) and left to react overnight at room temperature.

The build-in method Transfer Sample was chosen for sample measurement. This method executes sample collection from the autosampler, sample concentration determination prior to measurement, and optimization of the measurement conditions, all fully automated. Figure 3. Sample preparation description a) Load the sample in the cleaned vial (prior using, vial should be rinsed 3 times with de-ionized water and dried overnight at 70 C) b) Flush the vials with carrier for 3 minutes with autosampler c) Add 3 μl of acid to the vial d) Overnight reaction of the acid and sample at stable room temperature e) Start the measurement. Setting up samples in the tray and measurement Samples and reference materials were interspersed in the autosampler tray to check whether large differences in delta values of the different carbonate samples affect the measurement of the next sample, e.g. to test for any memory effect. Sampling and measurement procedure were generated automatically by Qtegra ISDS Software. The labbook used for the analysis is shown in Figure 4. Each sample measurement was followed by a measurement of a working standard gas (Ref. 1) to correct for instrument drift. In order to gain maximum precision, both samples and working standards were measured for 180 seconds. Prior to each sample transfer, the Variable Volume and plumbing was flushed with twice with Carrier by means of an Action Script ( Preclean D ). Analysis of the results For each instrument, the molecular ratios of NBS 19 and LSVEC were used to perform a two-point calibration of the type: R_expected = m * R_measured + b, with m being the slope an b the offset. These equations were then applied to the measured isotope ratios of NBS 18. Figure 5 shows measurement results of one instrument for all samples and references. Figure 4. Setup of the labbook in Qtegra ISDS Software (excerpt). Prior to sample measurement, carrier was flushed through a vial and the autosampler to clean all external components (autosampler needle, plumbing) from residual ambient air ( AS cleaning ).

10 0-10 -20-30 -40 Instrument 3-50 10 15 20 25 30 Figure 5. Measurement results for the international reference materials NBS 18, NBS 19 and LSVEC. NBS 19 and LSVEC were used as calibration standards. Table 1. 13 C/ 12 C ratios ( ) of NBS 19 and LSVEC used for the calibration of the three instruments and obtained calibration functions. NBS 19 LSVEC Instrument 1 0.0111899 0.0106714 Instrument 2 0.0112002 0.0106583 Instrument 3 0.0111991 0.0106566 Calibration Function* = 1.04680-5.11578 10-4 = 1.00174-1.75901 10-5 = 1.00061-3.95357 10-6 * Expected 13 C/ 12 C ratios are = 0.0112020 for NBS 19 and = 0.0106592 for LSVEC. No memory effect between the samples Figure 6 shows that the d 13 C values obtained for NBS 18 are independent of those of the previous samples. The green and orange vertical lines indicate the sample positions of NBS 19 and LSVEC. This demonstrates that there is no significant memory effect when analyzing discrete samples with the Delta Ray IRIS. The mean values of the 20 replicates of NBS 18 measured with the Delta Ray IRIS are shown in Table 2 and in Figure 6 together with mean, median, minimum and maximum values as well as second and third quartile. Certified value of NBS 18 for d13c is -5.014 VPDB with a standard deviation of 0.035. Table 2. Mean values and standard deviation of NBS 18 measured with three independent Delta Ray IRIS Systems. Figure 6. d 13 C values of NBS 18 measured on three systems. The green and yellow lines indicate the position of NBS 19 and LSVEC samples. The small difference ΔΔ ( 0.3 ) between certified and measured value of NBS 18 is much less than the stated uncertainty of NBS 18 and demonstrates the excellent accuracy achievable with the Delta Ray IRIS. Instrument 1! Instrument 2 Instrument 3 δ 13 C Measured St. Dev. Instrument 1-5.018 0.076 Instrument 2-5.044 0.047 Instrument 3-5.015 0.061 δ 13 C Certified -5.01 ± 0.035 1 2 3 Instrument Figure 7. Mean, median, minimum and maximum values as well as second and third quartile of the 20 replicates of NBS 18 measured on three Delta Ray IRIS Systems. The blue horizontal line and shading refer to the certified value of -5.01 ± 0.035 VPDB.

Conclusion The Delta Ray IRIS with URI Connect can be used for precise and accurate measurements of the d 13 C values from DIC. Samples containing 200-300 μg NBS 18 Calcite were measured with an accuracy better than 0.3 VPDB on three instruments. The precision over 20 vials was better than 0.08 for all instruments. The performance of the Delta Ray IRIS with URI Connect for the measurement of carbonates and DIC therefore is comparable to that of established applications like the Thermo Scientific GasBench II System. Additionally, the Delta Ray IRIS allows the researcher to obtain highly accurate and precise data also in the field. Reference 1. IAEA Reference Material Online Catalog: https://nucleus.iaea.org/rpst/ referenceproducts/referencematerials/index.htm Find out more at thermofisher.com/deltaray For Research Use Only. Not for use in diagnostic procedures. 2017 Thermo Fisher Scientific Inc. All rights reserved. Teledyne CETAC is a trademark of Teledyne Technologies Inc. All other trademarks are the property of Thermo Fisher Scientific. This information is presented as an example of the capabilities of Thermo Fisher Scientific products. It is not intended to encourage use of these products in any manner that might infringe the intellectual property rights of others. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. AN30367-EN 0617