Effect of Magnetic field on Hydrocarbon refrigerant

Similar documents
Experimental Investigation of Effect of Magnetic Field on Hydrocarbon Refrigerant in Vapor Compression Cycle

Property Data for Low-GWP Refrigerants: What Do We Know and What Don t We Know?

Performance Comparison in Retrofit

Development of Zero ODP, Less TEWI, Binary, Ternary and Quaternary Mixtures to Replace HCFC-22 in Window Air-Conditioner

Glide Effect on Performance

a. Key Laboratory of Efficient Utilization of Low and Medium Grade Energy, MOE, Tianjin University, Tianjin , China

A computerized analytical model for evaluating hydrocarbon fluids as natural alternative refrigerants

Mathematical Modelling for Refrigerant Flow in Diabatic Capillary Tube

Department of Mechanical Engineering, Kasetsart University, Si Racha Campus, Chonburi, Thailand *

4.1. Physics Module Form 4 Chapter 4 - Heat GCKL UNDERSTANDING THERMAL EQUILIBRIUM. What is thermal equilibrium?

SEM-2016(03)-II MECHANICAL ENGINEERING. Paper -11. Please read each of the following instructions carefully before. attempting questions.

Rating Charts of R-22 Alternatives Flow through Adiabatic Capillary Tubes

BME-A PREVIOUS YEAR QUESTIONS

MATHEMATICAL MODEL OF A VAPOUR ABSORPTION REFRIGERATION UNIT

Section 24.8 Magnets and Magnetic Materials Pearson Education, Inc.

Put sufficient ice cubes into water (1 M) and wait for equilibrium (both exist) (1 M)

4.1. Physics Module Form 4 Chapter 4 - Heat GCKL UNDERSTANDING THERMAL EQUILIBRIUM. What is thermal equilibrium?

ZHEJIANG FOTECH INTERNATIONAL CO., LTD.

Modification In Charging Composition In Order To Arrive At Desired Circulation Composition In The Context Of Sorption Compressor Based J-T Cooler

Refrigeration. 05/04/2011 T.Al-Shemmeri 1

R13 SET - 1 '' ''' '' ' '''' Code No RT21033

Common Terms, Definitions and Conversion Factors

SECOND ENGINEER REG. III/2 APPLIED HEAT

(ii) the total kinetic energy of the gas molecules (1 mark) (iii) the total potential energy of the gas molecules (1 mark)

8.21 The Physics of Energy Fall 2009

Solkane 410 Thermodynamics

UNIT I Basic concepts and Work & Heat Transfer

6. (6) Show all the steps of how to convert 50.0 F into its equivalent on the Kelvin scale.

SEM-2017(03HI MECHANICAL ENGINEERING. Paper II. Please read each of the following instructions carefully before attempting questions.

Pressure Distribution of Refrigerant Flow in an Adiabatic Capillary Tube

OVERVIEW. Air-Standard Power Cycles (open cycle)


1. INTRODUCTION TO REFRIGERATION AND AIR CONDITION

Pure Substance Properties and Equation of State

SHRI RAMSWAROOP MEMORIAL COLLEGE OF ENGG. & MANAGEMENT

UBMCC11 - THERMODYNAMICS. B.E (Marine Engineering) B 16 BASIC CONCEPTS AND FIRST LAW PART- A

A Study of Properties, Preparation and Testing of Magneto-Rheological (MR) Fluid

MAHALAKSHMI ENGINEERING COLLEGE

Simulation of a Thermo-Acoustic Refrigerator

THE METHOD OF THE WORKING FLUID SELECTION FOR ORGANIC RANKINE CYCLE (ORC) SYSTEM WITH VOLUMETRIC EXPANDER. * Corresponding Author ABSTRACT

4.3.1 Changes of state and the particle model Density of materials. ρ = m. Content. Key opportunities for skills development

Lecture 38: Vapor-compression refrigeration systems

1. Thermal energy is transferred through the glass windows of a house mainly by. D. radiation and convection. (1)

Effect of Coiled Capillary Tube Pitch on Vapor Compression Refrigeration System Performance.

Lesson 6 Matter. Introduction: Connecting Your Learning

A Review On Solar Adsorption Refrigeration System

Spring_#7. Thermodynamics. Youngsuk Nam.

Performance Investigation on Electrochemical Compressor with Ammonia

THE ENERGY 68,SAVING TDVI. exible Combine Modular 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44 HP 60, 62, 64, 66 HP

THE FIRST LAW APPLIED TO STEADY FLOW PROCESSES

Preface Acknowledgments Nomenclature

SECOND LAW OF THERMODYNAMICS

VRF Technical Data Book

Study Guide Unit 3 Chapter 6 DRAFT

R13. II B. Tech I Semester Regular Examinations, Jan THERMODYNAMICS (Com. to ME, AE, AME) PART- A

Homework - Lecture 11.

Types of Magnetism and Magnetic Domains

I. (20%) Answer the following True (T) or False (F). If false, explain why for full credit.

20 m neon m propane. g 20. Problems with solutions:

Advanced heat driven hybrid refrigeration and heat pump systems. Z. Tamainot-Telto School Engineering University of Warwick Coventry CV4 7AL - UK)

Eliminator Liquid line filter driers, Type DCL and DML

Topic 3 &10 Review Thermodynamics

Topic 19b. Thermal Properties of Matter

Chemical Engineering Thermodynamics Spring 2002

FINAL EXAM. ME 200 Thermodynamics I, Spring 2013 CIRCLE YOUR LECTURE BELOW:

Elements of Mechanical Engineering

RESONANCE ANALYSIS OF VALVED LINEAR COMPRESSOR FOR REFRIGERATION APPLICATION

Chapter 2: The Physical Properties of Pure Compounds

MAE 320 HW 7B. 1e. For an isolated system, please circle the parameter which will change with time. (a) Total energy;

Where F1 is the force and dl1 is the infinitesimal displacement, but F1 = p1a1

Solkane 134a Thermodynamics

CHAPTER 3 TEST REVIEW

Estimate, for this water, the specific heat capacity, specific heat capacity =... J kg 1 K 1. the specific latent heat of vaporisation.

The Effects of Friction Factors on Capillary Tube Length

7. (2) Of these elements, which has the greatest number of atoms in a mole? a. hydrogen (H) b. oxygen (O) c. iron (Fe) d. gold (Au) e. all tie.

Transient Modeling of a Thermosiphon based Air Conditioner with Compact Thermal Storage: Modeling and Validation

Magnetic materials, & inductance & Torque. P.Ravindran, PHY041: Electricity & Magnetism 8 February 2013: Magnetic materials, inductance, and torque

Heat Transfer Predictions for Carbon Dioxide in Boiling Through Fundamental Modelling Implementing a Combination of Nusselt Number Correlations

INDIAN INSTITUTE OF TECHNOLOGY ROORKEE NPTEL NPTEL ONLINE CERTIFICATION COURSE. Refrigeration and Air-conditioning

A Numerical Study on Static and Dynamic Characteristics of Electromagnetic Air Compressor used in Household Refrigerators

Chapter 3. Basic Principles. Contents

New High Pressure Low-GWP Azeotropic and Near-Azeotropic Refrigerant Blends

ME 354 THERMODYNAMICS 2 MIDTERM EXAMINATION. Instructor: R. Culham. Name: Student ID Number: Instructions

Investigations on Performance of an Auto-Cascade Absorption Refrigeration System Operating with Mixed Refrigerants

Introduction to Heat and Mass Transfer

P6 Molecules and matter. Student Book answers. P6.1 Density. Question Answer Marks Guidance. 1 a m 3 (= 0.80 m 0.60 m 0.

(Heat capacity c is also called specific heat) this means that the heat capacity number c for water is 1 calorie/gram-k.

Evaporation Heat Transfer Coefficients Of R-446A And R-1234ze(E)

Two mark questions and answers UNIT I BASIC CONCEPT AND FIRST LAW SVCET

2. be aware of the thermal properties of materials and their practical importance in everyday life;

Chapter 9. Preview. Objectives Defining Temperature. Thermal Equilibrium. Thermal Expansion Measuring Temperature. Section 1 Temperature and

ME6301- ENGINEERING THERMODYNAMICS UNIT I BASIC CONCEPT AND FIRST LAW PART-A

THE VAPOR COMPRESSION REFRIGERATION PROCESS

MAE 11. Homework 8: Solutions 11/30/2018

Ttions, and its relation to states of matter. This chapter covers the

Solenoid valves Type EVR 2 g 40 NC/ NO New EVR 6 with Steel cover design

PTT 277/3 APPLIED THERMODYNAMICS SEM 1 (2013/2014)

Applied Thermodynamics for Marine Systems Prof. P. K. Das Department of Mechanical Engineering Indian Institute of Technology, Kharagpur

TOLERANCES AND UNCERTAINTIES IN PERFORMANCE DATA OF REFRIGERANT COMPRESSORS JANUARY 2017

Transcription:

Effect of Magnetic field on Hydrocarbon refrigerant Sagar Patil 1, Nahush Kamble 2, Jay Kadam 3, Saurabh Patil 4,Ajaj Attar 5 1 B.E., Mechanical Department, Smt. Kashibai Navale College of Engg, sagarnpatil.sp@gmail.com 2 B.E., Mechanical Department, Smt. Kashibai Navale College of Engg,, nahushdkamble@gmail.com 3 B.E., Mechanical Department, Smt. Kashibai Navale College of Engg, jaykadam70@gmail.com 4 B.E., Mechanical Department, Smt. Kashibai Navale College of Engg., saurabh.patttil@gmail.com 5 Asst.Prof, Mechanical Department, Smt. Kashibai Navale College of Engg., ajaj.tech77@gmail.com ABSTRACT Performance test results of alternative refrigerant blendof R600A and R290 under various conditions of magnetic field are discussed, analysed and presented. The test results were obtained using a test setup of vapour compression cycle under various magnetic field conditions. Performance tests were conducted according to the ARI/ASHRAE Standards.Magnetic field being a source of energyshows influence on various materials and fluids which respond to the magnetic field. The vapour compression cycle is a well-established refrigeration technique used in most household refrigerators, air conditioners, and many large commercial and industrial refrigeration systems. However, mankind is facing serious problems concerning the global environment, and the emissionsof conventional refrigerant fluids such as chlorofluorocarbon (CFC), hydrochlorofluorocarbon(hcfc) and hydrofluorocarbon(hfc) are responsible for ozone depletion or the greenhouse effect.the effect of magnetic field on mixture behaviour varies by using different permanent magnets of various gauss strength. Furthermore, the use of magnetic field appears to have a positive influence on the system COP as well as thermal capacities of condenser and evaporator.most materials respond to an applied B-field by producing their own magnetization M and therefore their own B-field. Typically, the response is weak and exists only when the magnetic field is applied. The term magnetism describes how materials respond on the microscopic level to an applied magnetic field and is used to categorize the magnetic phase of a material.. Materials that can be magnetized and are also the ones attracted to a magnet are called ferromagnetic (or ferromagnetic). These include iron, nickel, cobalt, some alloys of rare-earth metals, and some naturally occurring minerals such as lodestone. Keywords: Permanent magnets, refrigerants, magnetic effect, vapour compression cycle. ----------------------------------------------------------------------------------------------------------------------------- 1. INTRODUCTION Vapour compression refrigeration systems are available to suit almost all applications with the refrigeration capacities ranging from few watts to few megawatts. A wide variety of refrigerants can be used in these systems to suit different applications, capacities etc. The actual vapour compression cycle is based on Evans-Perkins cycle, which is also called as Reverse Rankine cycle. Before the actual cycle is discussed and analysed, it is essential to find the upper limit of performance of vapour compression cycles. This limit is set by a completely reversible cycle. A magnetic field is the magnetic effect of electric currents and magnetic materials. The magnetic field at any given point is specified by both direction and a magnitude (or strength); as such it is represented by a vector field.this magnetic field is invisible but is responsible for the most notable property of a magnet, a force that pulls on other ferromagnetic materials, such as iron, and attracts or repels other magnets. A permanent magnet is an object made from a material that is magnetized and creates its own persistent magnetic field. An everyday example is a refrigerator magnet used to hold notes on a refrigerator door. 2.LITERATURE REVIEW In this experiment four pairs of permanent magnet of 3000 gauss field strength; are installed at fixed distance on the refrigerant liquid line (exit of condenser) of the VCC setup. The comparison of the set up performance is done with and without application of magnetic field to estimate the improvement in the VCC system. Experiments are carried 1443

out on hydrocarbon (R-404a) refrigerant. The test results mainly focus on the application of magnetic field which has a positive effect on the COP and power consumption of the system for the refrigerant. The net result is improvement in the COP of the VCC and reduction in the compressor power consumption.[1]. Fig-1 Variation of Refrigerating Effect VS No. of Magnet pairs This paper presents an experimental study on the replacement of CFC12 and HFC 134a by the new R290/R600a refrigerant mixture as drop-in replacement refrigerant with and without the effect of magnetic field.the test results with no magnets showed that the refrigerant R290/R600a had 19.9-50.1% higher refrigerating capacity than R12 and 28.6-87.2% than R134a.[2]. Fig-2COP vs T e with and without magnetic field effect for T c =35 0 C, T c =40 0 C The paper presents review of Effect of magnetic field on Hydrocarbon fluid flow (Refrigerant-R600). Published reports use of permanent magnets with different intensity (2000, 4000, 6000, 9000 Gauss) installed on the fuel line of the two-stroke engine, and study its wallop on fuel consumption, as well as emissions of exhaust gas and compared with performance without application of magnetic field to estimate the performance betterment.[3] 1444

Fig-3 Reducing the amount of consumed fuel with increasing magnetic field intensity 3. TYPES OF MAGNETIC MATERIALS A magnet is a material or object that produces a magnetic field. A permanent magnet is an object made from a material that is magnetized and creates its own persistent magnetic field. 3.1 Paramagnetic Materials It is a result of unpaired electrons within an atom that can cause a magnetic dipole to form in the presence of a magnetic field and, as a result, in the presence of a magnetic field this effect causes the fluid to be drawn in the direction of increasing magnetic field strength. 3.2 Diamagnetic Materials If the electrons are already paired, the atoms resist the formation of a dipole and this resistance causes the atoms to move in the direction of decreasing magnetic field strength, known as diamagnetism. 3.3 Ferromagnetic Materials Materials that can be magnetized and are also the ones attracted to a magnet are called ferromagnetic (or ferrimagnetic). These include iron, nickel, cobalt, some alloys of rare-earth metals, and some naturally occurring minerals such as lodestone Fig-4: Comparison between diamagnetic, paramagnetic and ferromagnetic materials The diagram above shows the reaction of molecules to paramagnetic, diamagnetic and ferromagnetic materials. As shown in the figure as the field strength increases the molecules start to flow in a single direction.this one directional flow increases the velocity of flow. 1445

4. HYDROCARBON REFRIGERANTS 4.1 R290/R600a (Propane + Isobutane) It is an azeotropic mixture of propane (R290) & isobutane (R600a). It has properties very similar to R12 &R134a which are the commonly used refrigerant nowa days. It contains 60%propane+40%iso butane. It is named as mint gas because it has cooling property like mint. Moreover ithas zero ozone depletion potential and a reliable globalwarming potential (the two property due to which weneed to replace the CFC s). This blend is used for domestic refrigerators because of its following reasons- 1. Zero GWP 2. Compatible with mineral oil. 3. Pressure same as in R12 system. Almost like a dropin substitute. 4. Low discharge/winding temperatures. 5. Quantity of charge very small. 6. Easily available. 4.2 R-12 Dichlorodifluoromethane (CCL2F2) R-12 is a very popular refrigerant. It is a colorless almost odorless liquid with boiling point of -29 0 C atatmospheric pressure. It is non-toxic, non-corrosive, non-irritating and non-flammable. It has a relativelylow latent heat value which is an advantage in smallrefrigeration machines. R-12 has a pressure of 0.82 bar at -15 0 C and a pressure of 6.4 bar at 30 0 c. The latentheat of R-12 at -15 0 Cis 159KJ/kg. 4.3 R-134a Tetraflouroethane (C2H2F4) The preferred replacements of R-12 can be the HFC refrigerants R-134a. This has a boiling point of -26.2 0 C which bears reasonable comparison with the boiling point of R-12 (-29.8 0 C). R-134 is a not a drop in replacement of R-12 because the refrigerating effect is slightly different. This would appear to be non-flammable and non toxic substitute for R-12 at extreme pressure ratios. 4.4 Refrigerant Selection: The refrigerant selected for the experiment is the blend of (R290+R600a) i.e. Propane + Isobutane. 5.EXPERIMENTAL PROCEDURE Experimentation is carried out with and without the application of magnetic field. Following procedure is to be followed while carrying out experimentation: Plug in and switch on the setup Ensure that the suction and discharge pressure is constant. Connect all the thermocouples to the points specified. Switch the thermocouple setting to Kelvin. Take the first reading of the temperatures after starting the setup Repeat the above point after the interval of 20 to 30 min. Repeat it until the compressor stops working and note down the temperature. Now use permanent magnets of different strengths at condenser exit and repeat the whole procedure. 6. EXPERIMENTAL SETUP 1446

Fig-5 Actual Test Setup Components of the test setup: 1: Compressor 2: Condenser 3: Evaporator and Storage tank 4: Capillary tube 5: Pressure gauge 6: Thermocouple 7: Permanent Magnets Refrigerant used in the setup: (R290:R600a) = (60%:40%) Magnets used in the setup: Permanent magnets of 3000 Gauss strength 7. RESULT AND DISCUSSION A) Variation of water temperature VS time for (R290/R600a): Case 1: Variation of temperature without magnet Case 2: Variation of temperature with a pair of N52 grade magnet Case 3: Variation of temperature with a pair of N35 grade magnet Case 4: Variation of temperature with one N50 and N35 grade magnet 1447

Compressor consumption(w) temperature International Conference on Ideas, Impact and Innovation in Mechanical Engineering (ICIIIME 2017) ISSN: 2321-8169 35 30 25 20 15 10 5 0 Temperature v/s Time 0 2 4 6 8 10 12 14 time(sec) Case 1 Case 2 Case 3 Case 4 Chart-1 Output Temperature vs Time The above graph shows the variation of temperature of water in the storage tank with time. The graph is plotted with increasing number of magnetic pairs with magnetic field strength of 2000 gauss respectively and without any magnetic pair. The readings are considered with respect to the water temperature in the range of 30 o C-6 o C. It is found that after the application of magnetic field, time required to cool the water up to 6 o C is reduced. When one magnetic pair is used of N35 grade, the time required for the refrigerant to cool the water temperature up to 6 o C is reduced by 4% with respect to no magnetic pair applied. When further magnetic pair of N52 grade is used, the time reduction is by 16%. For the magnetic pair of one N52 and one N35grade, 8% time is reduced. The maximum time saved is found in case of N50 magnetic pair. The reduction in time is obtained because of the increase in the specific heat of the refrigerant due to the magnetic field. B) Variation of Compressor Power with number of magnets: Compressor Power (kw) vs Number of Magnets 174 172 170 168 166 164 162 160 No Magnets 1 pair of N35 N35 & N52 1 pair of N52 No of magnets Chart-2 Compressor Power VS No. of Magnets 1448

When the magnetic field is applied because of the magnetic dipole moment various thermodynamic properties of refrigerant changes such as increase in specific heat of the refrigerant. As the specific heat of the refrigerant increases the evaporating effect increases because of which evaporation of refrigerant increases. As a result of above effects the compressor power reduces. Fromabove graph it can be concluded that maximum compressor power is saved when N52 grade magnetic pair is used. Thus, due to application of magnetic field compressor power reduces by 12%. 3. CONCLUSION The test results shows application of magnetic field has positive effect on the COP of the system for Hydrocarbon refrigerant.thus this study has been able to validate the reported phenomena of improvement in COP refrigerant systems on application ofmagnetic field between condenser outlet and TXV. By application of magnetic field to vapour line (i.e. compressor inlet) there is no change in refrigeration capacity or compressor power consumption. Performance defoliates after certain magnetic field strength COP = Mwater*CPw*(Tinitial Tfinal) / Compressor power Mwater = 20 kg, Cpw = 4187.23 J/kg-K Improvement in COP = (COP with application of magnetic field/ COP without application of magnetic field) * 100. 15% COP improvement is experimentally observed with application of the magnetic field on R600a/R290. REFERENCES 1] Experimental Investigation on the Effect of Magnetic Field on Refrigerants by Krushad Shinde, Pradnil Shinde, Devendra Tupe, Pradeep Rathod. 2] Energy savings with the Effect of Magnetic field using R290/600a mixture as substitute for CFC12 and HFC134a by Kolandavel Mani and Velappan Selladurai. 3] Investigate Effects of Magnetic Fields on Fuels Rongjia Tao, Department of Physics, Temple University, Philadelphia, PA 19122 March 15, 2004 5] Experimental Investigation for the Magnetic-Caloric Effect on the Refrigeration Cycle Performance A Kotb, H. E. Saad* Department of Mechanical Power Engineering, Faculty of Engineering, Ain Shams University, Cairo, AbdoBasha, El Sarayat St., 1, Egypt. 6] Comparative analysis of R290/R600A with commonly used refrigerants. Ajay Bhargav, Nitin Jaiswal, Mechanical Engineering. Acropolis Tech College. 7] Performance Analysis of Mixtures of R290 and R600a With Respect To R134a in simple Vapour Compression Refrigeration System Jagnarayan Rawani, Satyendra Kumar Prasad, Jitendra Nath Mahto, Department of Mechanical Engineering, BIT Sindri, Dhanbad, Jharkhand,India. 8] Thermophysical Properties of Refrigerants,Chapter 30 ASHRAE Handbook-Fundamentals. 1449