A S ENSIT IV E M E T HO D FO R T H E D E T E RM INAT IO N O F ENDO C RIN E- D IS RU P T ING COM P OUNDS IN RIV E R WAT E R BY L C / MS/MS

Similar documents
Analysis of Serum 17-Hydroxyprogesterone, Androstenedione, and Cortisol by UPLC-MS/MS for Clinical Research

Improved Extraction of THC and its Metabolites from Oral Fluid Using Oasis PRiME HLB Solid Phase Extraction (SPE) and a UPLC CORTECS C 18

Jonathan P. Danaceau, Erin E. Chambers, and Kenneth J. Fountain Waters Corporation, Milford, MA USA APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS

Toxicity, Teratogenic and Estrogenic Effects of Bisphenol A and its Alternative. Replacements Bisphenol S, Bisphenol F and Bisphenol AF in Zebrafish.

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

Determination of Pharmaceuticals in Environmental Samples

A Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

Determination of Hormones in Drinking Water by LC/MS/MS Using an Agilent InfinityLab Poroshell HPH Column (EPA 539)

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

Supporting Information. Detection and Occurrence of Chlorinated By-products of Bisphenol A, Nonylphenol and

LC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode

Sensitive and Repeatable Analysis of Pesticides in QuEChERS Extracts with APGC-MS/MS

DETERMINATION OF PESTICIDES IN FOOD USING UPLC WITH POLARITY SWITCHING TANDEM QUADRUPOLE LC/MS/MS

Identification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate

[application note] INTRODUCTION EXPERIMENTAL. Specimens. Extraction

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

A Case of Pesticide Poisoning: The Use of a Broad-Scope Tof Screening Approach in Wildlife Protection

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEY WORDS. Simultaneous high-throughput screening of melamine (MEL) and cyanuric acid (CYA).

Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS

Rapid, Reliable Metabolite Ratio Evaluation for MIST Assessments in Drug Discovery and Preclinical Studies

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

T H E ANA LYSIS O F DIOX INS AND F U R A NS USING H RG C- H IG H R E SO LU T IO N MS W IT H T H E AU T OS P EC- ULTIMA NT

High-Throughput LC-MS/MS Quantification of Estrone (E1) and Estradiol (E2) in Human Blood Plasma/Serum for Clinical Research Purposes

Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS

Analysis of Synthetic Cannabinoids and Metabolites: Adding New Compounds to an Existing LC-MS/MS Method

University of the Aegean

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

Highly sensitive and rapid analysis of synthetic dyes in sea food by LC/MS/MS

Application of ultra performance liquid chromatography tandem mass spectrometry to the analysis of priority pesticides in groundwater

Analysis of Pharmaceuticals and Personal Care Products in River Water Samples by UHPLC-TOF

Extraction of Cocaine and Metabolites From Urine Using ISOLUTE SLE+ prior to LC-MS/MS Analysis

Quantitative analysis of small molecules in biological samples. Jeevan Prasain, Ph.D. Department of Pharmacology & Toxicology, UAB.

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Extraction of Methylmalonic Acid from Serum Using ISOLUTE. SAX Prior to LC-MS/MS Analysis

Quantitation of High Resolution MS Data Using UNIFI: Acquiring and Processing Full Scan or Tof-MRM (Targeted HRMS) Datasets for Quantitative Assays

C HA R AC T E RIZ AT IO N O F INK J E T P RINT E R C A RT RIDG E INK S USING A CHEMOMETRIC APPROACH

DETERMINATION OF OCs, PCBs AND SYNTHETIC PYRETHROIDS IN ANIMAL FAT

APPLICATIONS TN Increased Capabilities for the Analysis of Hormones in Drinking and Waste Water Using Solid Phase Extraction (SPE) and LC/MS/MS

ApplicationNOTE THE ANALYSIS OF POLYCHLORINATED BIPHENYLS (PCBS) BY GC-HIGH RESOLUTION MASS SPECTROMETRY USING THE MICROMASS AUTOSPEC ULTIMA NT

Quantitative analysis of mitragynine in human urine by high performance liquid chromatography-tandem mass spectrometry

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Agilent 6460 Triple Quadrupole LC/MS System with an Agilent 1290 Infinity LC For Multi-Plant Growth Regulator Analysis in Grapes

A Workflow Approach for the Identification and Structural Elucidation of Impurities of Quetiapine Hemifumarate Drug Substance

A Fully Validated LC-MS/MS Method for Analysis of Trace Fluorotelomer Alcohols from Water

A New Polymer-based SPE Sorbent to Reduce Matrix Effects in Bioanalytical LC-MS/MS

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Evaluation of a New HPLC, a New Tandem MS and a New Data Processing Software for General Clinical Use

Supporting Information

Analysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS

Plasma-free Metanephrines Quantitation with Automated Online Sample Preparation and a Liquid Chromatography-Tandem Mass Spectrometry Method

Determination of iopromide in environmental waters by ion chromatography-icp-ms

Optimization of the sample preparation and extraction methodology

Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide Residue Analysis

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

[ Care and Use Manual ]

Determination of Pharmaceuticals in Water by SPE and LC/MS/MS in Both Positive and Negative Ion Modes Application

Assay Robustness Improvement for Drug Urinalysis Using FAIMS and H-SRM on a Triple- Quadrupole Mass Spectrometer

Traditional Herbal Medicine Structural Elucidation using SYNAPT HDMS

Streamlining the Analysis of Oral Contraceptives Using the ACQUITY UPLC H-Class System

Hints and Tips for APGC Coupled with Xevo TQ-S for Food and Environmental Analysis

UPLC Intact MASS Analysis Application Kit

Simultaneous analysis for forensic drugs in human blood and urine using ultra-high speed LC-MS/MS

[ APPLICATION NOTEBOOK ] MASS SPECTROMETRY APPLICATION SOLUTIONS FOR ENDOCRINOLOGY RESEARCH

Ultrafast Analysis of Buprenorphine and Norbuprenorphine in Urine Using the Agilent RapidFire High-Throughput Mass Spectrometry System

16 Malachite green 17 Leucomalachite green

High-sensitivity, high-throughput quantitation of catecholamine metabolites in urine by LC/MS/MS for clinical research

Extraction of Aflatoxins and Ochratoxin from Dried Chili Using ISOLUTE. Myco Prior to LC-MS/MS Analysis

OVERVIEW INTRODUCTION. Michael O Leary, Jennifer Gough, Tanya Tollifson Waters Corporation, Milford, MA USA

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)

materials analysis Solutions for Your Analytical Business Markets and Applications Programs

[application note] ACQUITY UPLC/SQD ANALYSIS OF POLYMER ADDITIVES. Peter J. Lee, and Alice J. Di Gioia, Waters Corporation, Milford, MA, U.S.A.

Aminoglycosides in Milk Using Agilent Bond Elut Plexa SPE, Agilent Poroshell 120, and LC/Tandem MS

Clinical Toxicology. Biomass Component Extraction: The uneaten cooked plant specimen was prepared for

Mixed-Mode, Weak Anion-Exchange, Solid-Phase Extraction Method for the Extraction of Niflumic Acid from Human Plasma

isobaric Barbiturates in Serum using LDTD- MS/MS combined with differential mobility

[ a ppl ic at ion no t e ]

Simultaneous Determination of Paraquat and Diquat in Environmental Water Samples by HPLC-MS/MS

PosterREPRINT COMPARISON OF PEAK PARKING VERSUS AUTOMATED FRACTION ANALYSIS OF A COMPLEX PROTEIN MIXTURE. Introduction

Multi-stage Mass Spectrometry up to MS 4 on a QTof System

ApplicationNOTE ULTRA TRACE ANALYSIS OF DIOXINS AND FURANS IN HUMAN ADIPOSE TISSUE USING SFE-LC EXTRACTION/CLEANUP AND THE WATERS AUTOSPEC ULTIMA NT

Q-TOF PREMIER DYNAMIC RANGE ENHANCEMENT AND ACCURATE MASS MEASUREMENT PERFORMANCE

Identification of Human Hemoglobin Protein Variants Using Electrospray Ionization-Electron Transfer Dissociation Mass Spectrometry

Figure 1. The supported liquid extraction process using the ISOLUTE SLE plate (single well shown)

Automated Large-Volume Injection for Direct Analysis of Alkylphenols and Ethoxylated Alkylphenols by Mixed-Mode Chromatography and Mass Spectrometry

The Emergence of Benchtop Tandem Quadrupole Mass Spectrometers as a Routine Tool in Quantitative GC/MS/MS Applications

Routine MS Detection for USP Chromatographic Methods

Application Note. Abstract. Authors. Environmental

Agilent 6495 Triple Quadrupole LC/MS System EXPERIENCE A NEW LEVEL OF CONFIDENCE

The Waters Acquity Ultra-Performance Liquid Chromatograph and the Micromass Quattro Premier Triple Quadrupole Mass Spectrometer

Fast Analysis of Chlorinated Phenoxy Herbicides in Environmental Samples by Negative ESI LC-MS/MS 14337

Determination of Pesticide Residues in Oats by Automated. QuEChERS and LC/QQQ. Application Note. Abstract. Introduction

ApplicationNOTE A STUDY OF THE ANALYSIS OF POLYBROMINATED DIPHENYL ETHER FLAME RETARDANTS BY GC/MS/MS. Introduction. Materials and Methods

Rapid method development to study plasma stability of diverse pharmaceutical compounds using Rapid Resolution LC and triple quadrupole MS

Abstract. Experimental Sample Preparation

Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry

The Effect of Contact Angle and Wetting on Performance in Solid Phase Extraction

A High Sensitivity Dual Solid Phase Extraction LC-MS/MS Assay for the Determination of the Therapeutic Peptide Desmopressin in Human Plasma

Transcription:

[ application note ] A S ENSIT IV E M E T HO D FO R T H E D E T E RM INAT IO N O F ENDO C RIN E- D IS RU P T ING COM P OUNDS IN RIV E R WAT E R BY L C / MS/MS Patricia Revilla-Ruiz 1, Gordon Kearney 2, Daniel McMillan 2, and Encarnación Rodriguez-Gonzalo 1 1 Universidad de Salamanca, Salamanca, Spain 2 Waters Corporation, Manchester, UK INT RODUCTION Emerging evidence from wildlife and laboratory studies indicates that some chemicals may interfere with the endocrine system. Compounds identified as endocrine-disrupting chemicals (EDCs) include pesticides, polychlorinated biphenyls (PCBs), dioxins, furans, alkylphenols, and steroid hormones (natural and synthetic). The steroid hormones are of special concern due to their potency. The natural sex hormone estradiol and its metabolites (estrone and estriol) and the synthetic steroid ethinylestradiol are excreted in the urine of mammals and can be found in surface and ground waters. Other EDCs, such as the alkylphenols nonylphenol, bisphenol A- and pentachlorophenol are derived from industrial and domestic activities and also occur in environmental waters. Bisphenol A is used in the production of epoxy resins and polycarbonate plastics which are utilized extensively in the manufacture of food and drink packaging materials. Nonylphenol, which is produced as a derivative of non-ionic surfactants, is used extensively as a plasticizer. Pentachlorophenol is still used in some countries as a heavy-duty wood preservative. The environmental presence of these compounds highlights the need to develop highly sensitive and specific analytical methods. Liquid chromatography-tandem mass spectrometry (LC/MS/MS) is a technology applicable to a wide range of molecules and matrices, which provides the sensitivity required for trace analysis. Electrospray ionization (ESI) in negative ion (NI) mode is generally the method of choice for determination of estrogens, alkylphenols and chlorophenols 1,2. These chemicals have been shown in laboratory and field studies to provoke endocrine disruption at sub-ng/l levels. Thus, analyte enrichment is sometimes necessary in order to achieve the required detection limits. For pre-concentration of EDCs from aqueous samples, solid-phase extraction (SPE) is considered to be the most appropriate technique 3. This application note describes a sensitive method for the simultaneous determination of eight endocrine-disrupting compounds in river water samples based on SPE followed by LC/MS/MS. Alliance 2690 HPLC and Micromass Quattro micro mass spectrometer. MET HOD Solid-phase extraction The following extraction method was used 4 : Cartridge: Conditioning: Load: Sample: Wash: Elute: Evaporate: Waters Oasis HLB (60 mg) 3 ml Methyl t-butyl ether (MTBE) 3 ml Methanol (MeOH) 3 ml ultra-high quality water 500 ml acidified river water (10 mm formate buffer ph=3.0) 3 ml 40% MeOH in UHQ water 3 ml UHQ water 3 ml 10% MeOH/2% NH 4 OH in water 6 ml 10% MeOH/MTBE to dryness by gentle stream of nitrogen at 50 C Re-dissolution: 500 μl (50:50, v/v, acetonitrile/ ammonium formate buffer ph 3.0) 52

LC Conditions Waters Alliance 2690 HPLC system Mobile Phase A: Methanol Mobile Phase B: Water Column: Waters SunFire C 18, 2.1 x 50 mm with 3.5 μm particle size Flow rate: 0.2 ml/min Injection volume: 20 μl Gradient Time 0, 60% A; 40% B Time 10 min, 100% A Time 18 min, 100% A Time 20 min, 60% A; 40% B Time 23 min, 60% A; 40% B MS Conditions A Micromass Quattro micro triple quadrupole mass spectrometer was operated in the negative ion electrospray mode. Nitrogen gas, at a flow rate of 450 L/hr and a temperature of 250 C, was used for spray desolvation. The source temperature was maintained at 120 C and the capillary voltage was 3.2 kv. The MRM transitions, along with the optimum cone voltage and collision energy for the individual compound, are listed in Table 1. The ion used for quantitative determinations has been highlighted in bold font. In the case of pentachlorophenol, no significant fragmentation could be obtained even at high collision energy, but the full scan acquisition mode revealed that enough structural information is obtained due to the characteristic isotope ratio signals of the halide. Thus, for this compound, a SIR of four of its characteristic ions have been monitored. Data was acquired using Waters MassLynx software and processed using the TargetLynx Application Manager. RESULTS AND DISCUSSION The nature of all eight compounds studied makes them amenable to analysis by electrospray injection (ESI-) MS/MS. Methanol and acetonitrile, two organic solvents commonly used in reversed-phase LC, were evaluated. The MS signals for all the compounds assayed were higher for methanol than for acetonitrile, probably due to the more favorable ionization properties of the former solvent. Calibration models for the LC/(ESI-) MS/MS method were constructed by injecting standard solutions and obtaining a good linear relationship Compound Fw Precursor ion m/z Product ions m/z Corresponding structure of product ions Cone Voltage (V) Collision Energy (ev) Estriol 288.4 287.3 144.9; 171.1 [M - C 8 O 2 ] - ; [M - C 6 O 2 ] 50 40 Bisphenol A 228.3 227.2 133.0; 210.8 [M - C 6 H 6 O] - 37 33 17α-Ethinylestradiol 296.4 295.5 145.1; 199.5 [M - C 10 O] - ; [M - C 6 H 9 O] - 37 49 17α-Estradiol 272.4 271.3 145.2; 183.1 [M - C 10 O] - ; [M - C 5 O] - 37 45 17β-Estradiol 272.4 271.3 145.2; 183.1 [M - C 8 O] - ; [M - C 5 O] - 37 45 Estrone 270.4 269.2 144.8; 143 [M - C 8 O] - ; [M - C 8 O] - 37 33 4-n-Nonylphenol 220.4 219.3 106.0; 118.7 [M - C 8 H 17 ] - ; [M - C 7 H 17 ] - 40 34 Pentachlorophenol 266.3 SIR of 264.9; 263.0; 267.1; 269.0 40 - Table 1. MRM parameters. 53

[application note] between the analytical signal and analyte concentration for all compounds. Figure 1 shows a representative calibration curve for estrone generated in the concentration range of 0.5-100 ng/ml. This calibration curve was generated using solvent standards and the concentrations stated refer to the analyte concentration in the sample vial. Figure 2 shows the chromatograms for the compounds at the lowest calibrated level. The instrument LoDs in solvent standard (S/N ratio = 3 to 1) are estimated to be 0.6 ng/ml for estrone, 0.5 ng/ml for pentachlorophenol, 3 ng/ml for 17α-estradiol, 5 ng/ml for 17βestradiol, 10 ng/ml for bisphenola, 7 ng/ml for 4-n-nonylphenol, 5 ng/ml for estriol, and 30 ng/ml for 17α-ethinylestradiol. In order to obtain a more sensitive method for the quantification of these compounds in river water, a solid-phase extraction step with Oasis HLB cartridges was performed prior to chromatographic determination. A study with different volumes of river water samples was carried out first to evaluate if effects of matrix suppression or breakthrough appear when the volume of water to be pre-concentrated was increased. The results show that the signals were practically independent of the pre-concentrated sample volume. Accordingly, a 500 ml river water sample volume was selected. With the proposed SPE procedure, satisfactory percentage recoveries in river water were obtained ranging from 74% for 4-n-nonylphenol to 105% for 17α-ethinylestradiol. The whole procedure was applied to river water samples. The analysis of unspiked river water samples revealed that two of the compounds studied, bisphenol A and estrone were present, as can be seen in Figure 3. Figure 1. Calibration graph for estrone. Figure 2. Chromatograms showing peaks close to the instrument LoDs. To estimate the concentration of these two compounds in the river water sample, a standard addition method was performed. For the standard addition experiments, addition of known amounts of target analytes into the sample at four concentrations levels (1, 2, 4 and 8 ng/l for estrone and 0.25, 5, 10 and 20 ng/l for bisphenol A) was carried out. From the calibration curves obtained, the concentration found in river water is estimated to be 2 ±1 ng/l for estrone and 6 ±1 ng/l for bisphenol A. Figure 3. The presence of bisphenol A and estron in unspiked river water samples. 54

Figure 4 shows the chromatograms obtained after the SPE extraction, for river water samples spiked with the compounds at the lowest concentration level tested (except for bisphenol A and estrone for which chromatograms in unspiked river water are presented). From Figure 4, the method LoDs in river water (S/N ratio = 3 to 1) are estimated to be 1 ng/l for estrone, 0.6 ng/l for pentachlorophenol, 2.5 ng/l for 17α-estradiol, 5 ng/l for 17β-estradiol, 6 ng/l for bisphenol A, 9 ng/l for 4-n-nonylphenol, 12 ng/l for estriol, and 50 ng/l for 17α-ethinylestradiol. These estimates refer to the concentration of analyte spiked into the river water prior to extraction. Conc lusion A sensitive and selective LC/MS/MS method has been developed for the determination of eight endocrine-disrupting compounds in river water samples at low-nanogram per liter level. The 1000- fold concentration step in the sample preparation method improves the sensitivity of the analysis by 500 to 1000 fold, depending on analyte. This indicates that the SPE method used gives excellent analyte enrichment and cleanup, with minimal matrix effects. References 1. M.S. Díaz-Cruz, M.J. Lópezde Alda, R. López and D. Barceló; J. Mass Spectrom., 38 (2003) 917. 2. A. Laganá, A. Bacaloni, I. De Leva, A. Faberi, G. Fago and A. Marino; Anal. Chim. Acta, 501 (2004) 79. 3. M.J. Lópezde Alda and D. Barceló; J. Chromatogr. A, 938 (2001) 145. 4. Oasis Applications Notebook, Page 80, Waters Corporation. Figure 4. Chromatograms of spiked river water samples. 55

[application note] Waters, Alliance, Micromass, and Oasis are registered trademarks of Waters Corporation. Quattro micro, TargetLynx, SunFire, MassLynx and The Science of What s Possible are trademarks of Waters Corporation. All other trademarks are the property of their respective owners. 2005-2007 Waters Corporation. Produced in the U.S.A. June 2007 720001296EN RB-AC Waters Corporation 34 Maple Street Milford, MA 01757 U.S.A. T: 1 508 478 2000 F: 1 508 872 1990 www.waters.com