Fragment-Based Drug Discovery (FBDD) Using the dispr Technique on Pioneer Systems with OneStep and NeXtStep Injection Methodologies

Similar documents
Small-Molecule Kinetics

Small-Molecule Kinetics

Kinetic & Affinity Analysis

Introduction to FBDD Fragment screening methods and library design

protein interaction analysis bulletin 6300

FRAGMENT SCREENING IN LEAD DISCOVERY BY WEAK AFFINITY CHROMATOGRAPHY (WAC )

MicroCal itc 200. System MicroCal Auto-iTC 200. System. GE Healthcare Life Sciences. System design and description. provide:

NMR Solutions for drug discovery

Unlocking the potential of your drug discovery programme

Problem Set 5 Question 1

Implementation of novel tools to facilitate fragment-based drug discovery by NMR:

Fragment-based drug discovery

Elecsys with ECL technology Still light years ahead

Monolith NT.Automated Product Information

How antibody surface coverage on nanoparticles determines the. activity and kinetics of antigen capturing for biosensing

A Workflow Approach for the Identification and Structural Elucidation of Impurities of Quetiapine Hemifumarate Drug Substance

AB SCIEX SelexION Technology Used to Improve Mass Spectral Library Searching Scores by Removal of Isobaric Interferences

FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION

ImprovIng ADmE ScrEEnIng productivity In Drug DIScovEry

Protein Aggregate Assessment of Ligand Binding Assay (LBA) Reagents Using SEC-MALS

Receptor Based Drug Design (1)

Application Note. Authors. Introduction. Lauren E. Frick and William A. LaMarr Agilent Technologies, Inc. Wakefield, MA, USA

New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses

Characterization of Reversible Kinase Inhibitors using Microfluidic Mobility-Shift Assays

Meet Our Uncle: 12 Stability Applications on One Platform

Peptide Isolation Using the Prep 150 LC System

Strategies to compare far-uv Circular Dichroism spectra of similar proteins using Chirascan -plus ACD

Intelligent NMR productivity tools

COMBINATORIAL CHEMISTRY IN A HISTORICAL PERSPECTIVE

Isothermal Titration Calorimetry in Drug Discovery. Geoff Holdgate Structure & Biophysics, Discovery Sciences, AstraZeneca October 2017

Performing Peptide Bioanalysis Using High Resolution Mass Spectrometry with Target Enhancement MRM Acquisition

Reaxys Medicinal Chemistry Fact Sheet

Fragment Screening in Drug Discovery

Key Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery

Perseverance. Experimentation. Knowledge.

White Paper. Linear Range Determination in Empiria Studio Software

17. Biomolecular Interaction

The Vacuum Sorption Solution

Supporting Information. Labeled Ligand Displacement: Extending NMR-based Screening of Protein Targets

Gold nanoparticles from Innova Biosciences

Moscow Institute of Physics and Technology, Institutsky 9, Dolgoprudny , Russia 2

Preparation of Tritium Labeled Compounds and Their Scintillation Proximity Assays

Everyday NMR. Innovation with Integrity. Why infer when you can be sure? NMR

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

In silico pharmacology for drug discovery

Stephen McDonald and Mark D. Wrona Waters Corporation, Milford, MA, USA INT RO DU C T ION. Batch-from-Structure Analysis WAT E R S SO LU T IONS

Basic Principles for Purification Using Supercritical Fluid Chromatography

Accelerating the Metabolite Identification Process Using High Resolution Q-TOF Data and Mass-MetaSite Software

ABI 3200 Q TRAP LC/MS/MS System

Cheminformatics Role in Pharmaceutical Industry. Randal Chen Ph.D. Abbott Laboratories Aug. 23, 2004 ACS

Lecture 7. Surface Reaction Kinetics on a

Lirui Qiao, 1 Rob Lewis, 2 Alex Hooper, 2 James Morphet, 2 Xiaojie Tan, 1 Kate Yu 3

Applications of Fragment Based Approaches

Meet Stunner: The one-shot protein concentration and sizing combo

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

Hit Finding and Optimization Using BLAZE & FORGE

Gold Nanoparticles product guide. Innovative Reagents & Services for Life Sciences & Diagnostics

Important Aspects of Fragment Screening Collection Design

Commitment to Covalency: Kinetics of Irreversible Inhibitors with a Regenerable Streptavidin Sensor on the Pioneer FE System

In Silico Investigation of Off-Target Effects

György M. Keserű H2020 FRAGNET Network Hungarian Academy of Sciences

Label-Free Detection of Compound Aggregation Using Corning Epic Technology

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

Nucleic Acid Quantitation in Microplates

An automated synthesis programme for drug discovery

La RMN quantitative appliquée aux petites molécules

Powerful Scan Modes of QTRAP System Technology

Chirascan 6-Cell Peltier Cell Holder: Rapid Optimisation of Buffer Conditions for Stabilising Protein Therapeutics

Confirmation of In Vitro Nefazodone Metabolites using the Superior Fragmentation of the QTRAP 5500 LC/MS/MS System

LanthaScreen Eu Kinase Binding Assay Validation Packet. Optimization of a LanthaScreen Eu Kinase Binding Assay for AURKB

Malachite Green Phosphate Detection Kit Catalog Number: DY996

Binding Theory Equations for Affinity and Kinetics Analysis

Translational Biomarker Core

COMBINATORIAL CHEMISTRY: CURRENT APPROACH

CHAPTER 8 Analysis of FP Binding Data

cobas 8000 modular analyzer series Intelligent LabPower

Structure-Based Drug Discovery An Overview

Return on Investment in Discovery Chiral Separations

CSD. CSD-Enterprise. Access the CSD and ALL CCDC application software

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

GE Healthcare. Biacore T200. Software Handbook

An Evaluation of Various High-Resolution, Accurate-Mass Scan Modes for In Vitro Drug Discovery Screening

Conformational Characterization of Calmodulin by Hydrogen Deuterium Exchange Mass Spectrometry

Battle the heat in your lab

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

ActiPix SDI300 Surface Dissolution Imaging System

IN QUALITATIVE ANALYSIS,

Guide to Peptide Quantitation. Agilent clinical research

Online Reaction Monitoring of In-Process Manufacturing Samples by UPLC

IRMS. perspective. Isotope Ratio Mass Spectrometry.

C HA R AC T E RIZ AT IO N O F INK J E T P RINT E R C A RT RIDG E INK S USING A CHEMOMETRIC APPROACH

Mnova Software Tools for Fragment-Based Drug Discovery

CONFOCHECK. Innovation with Integrity. Infrared Protein Analysis FT-IR

WALKUP LC/MS FOR PHARMACEUTICAL R&D

ISoTherMal TITraTIon Calorimetry

LanthaScreen Eu Kinase Binding Assay Validation Packet. Optimization of a LanthaScreen Eu Kinase Binding Assay for RPS6KA1

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns

At-a-Glance. Verapamil C 27 H 38 N 2 O 4 M+H + =

Lateral Flow: Making Magnetic Particles A Viable And Easier To Use Replacement To Gold Nanoparticles.

Transcription:

APPLICATION NOTE 21 Fragment-Based Drug Discovery (FBDD) Using the dispr Technique on Pioneer Systems with OneStep and NeXtStep Injection Methodologies Eric L. Reese, Ph.D, SensiQ Technologies, Aaron Martin and David O. Apiyo, Ph.D, Marketing Applications Managers, Pall Fortebio Fragment-based drug design has become an increasingly popular platform for the identification of lead candidates in drug discovery programs. The detection and characterization of fragment binding events is facilitated by sensitive biophysical technologies capable of detecting low affinity interactions of low molecular weight compounds. Over the last decade approaches such as nuclear magnetic resonance (NMR), X-ray crystallography, differential scanning fluorimetry (DSF), and surface plasmon resonance (SPR) have become core technologies in many pharma and biotech settings for the identification of these low-affinity fragment compounds. In particular, SPR-based biosensors have sufficient sensitivity and throughput to provide complete fragment screens on libraries of several thousand compounds in just a few weeks per target. This application note describes how the dynamic injection SPR (dispr) technique, marks a quantum innovation in characterizing molecular interactions. Step 1 Capture Target Step 2 OneStep Step 3 NeXtStep Competition Key Protein Target Positive Ctrl Fragment Buffer Flow Assay Steps 1 Capture protein target to sufficient surface density 2 Verify target activity with a positive control 1 fragment library using OneStep Injections 2 Periodically verify target activity during the run 1 Prepare fragment hits mixed solution with control 2 Compete fragment hits with control using NeXtStep Injections 3 Confirm competitive fragments Typical Step Time 3 min 1 hr 768 fragments in 24 hrs (Pioneer FE system) 96 fragment hits in 9 hrs Advantages Low protein sample requirement: Most immobilization methods use <2 µg material Label-free: No tags required for detection Flexible: Pioneer systems can accommodate screening in diverse buffers and temperatures to enhance protein stability Fast: Assay setup, run-time and analysis are rapid steps Information rich: OneStep screens simultaneously identify and characterize (k a, k d, K D ) fragment hits Intuitive: User-friendly software enables confident analysis and identification of ideal/non-ideal fragments Fast: Assay setup, run-time and analysis are rapid steps Information rich: NeXtStep competition easily shows if fragments are competitive, non-competitive or un-competitive New data: NeXtStep Injections shows a fragment s competition K D which is beyond a yes/no answer Figure 1: A work-flow for Fragment ing on the Pioneer Systems 1

FBDD WITH ONESTEP AND NEXTSTEP INJECTION METHODOLOGIES A B OneStep (K D ) NeXtStep (Specificity) Characterized Hits Medicinal Chemistry Pilot Primary Secondary Characterized Hits Medicinal Chemistry Figure 2: A) Optimized workflow using dispr. Initial compound screening is followed by a specificity test analysis that leads to full characterization of the identified hits. The selected compounds can then be used in various applications in medicinal chemistry. B) Conventional fragment screening workflow. An initial screening process is followed by a secondary screening process where samples have to be prepared at different concentrations and analyzed separately to allow for affinity characterization and fragment hit confirmation. OneStep Injections use a continuous analyte titration method that provides reliable affinity measurements in a single injection, and is also suitable for rapid screening in both direct and competitive binding formats. It offers improvements in screening time and provides higher content information that allows for confident, rapid characterization of hits. At the core of dispr are the unique OneStep and NeXtStep Injection methodologies that advance binding characterization in multiple application areas throughout the drug discovery process. The two techniques can be used in tandem to fully characterize kinetic parameters and binding specificity of screened small molecules (Figure 1). FRAGMENT SCREENING WITH ONESTEP AND NEXTSTEP INJECTION TECHNIQUES Fragment screening is typically hampered by a host of technical challenges including large numbers of samples, low molecular weight analytes (< 3 Da) and weak affinity interactions (K D : 1 μm to 1 mm). Low molecular weight, weak affinity, and solubility limitations make it impractical to test for binding using sample concentrations above the K D and frequently results in making decisions based on inappropriate (small, square-shaped) sensorgrams. Increasing sample throughput and data content through the generation of gradients, while decreasing sample preparation time, OneStep Injections can dramatically improve SPR-based fragment screening. The technique is designed to streamline binding analysis by testing a full concentration series in a single injection. This not only saves sample preparation time and materials, but also reduces human error by eliminating the preparation of multiple sample dilutions. OneStep Injections also represent a significant improvement in how SPR biosensor assays are performed by streamlining the efficiency and accuracy of the workflow process. Secondary screening can either be reduced or completely avoided as fragment candidate selection is optimized during primary screening (Figure 2). The technique: Allows users to make decisions early on by obtaining reliable affinity (K D ) and kinetics (k a, k d ) data directly from the primary screen Provides fast time to first result, is fully automated and requires minimal assay development to arrive at the correct fragment candidate(s) Provides reproducible identification of fragment actives. Provides high throughput fragment actives analysis: up to 768 samples in 24 hours OneStep Injections eliminate the need for multiple sample preparations by generating a continuous concentration gradient using the sample and the running buffer. The data generated in a weakaffinity binding typically associated with fragments resembles an isotherm and can be fitted with a real-time equilibrium binding isotherm model. The fragment off-rates are often fast enough to allow for a steady-state approximation. The software provides models incorporating kinetics, mass-transport corrections, and multi-site binding parameters that can adequately describe different interactions. Therefore, primary screening data are ready for K D analysis without the need for laborious secondary screening and extra sample preparation steps. COMPARISON OF dispr AND CONVENTIONAL SPR IN FBDD A comparison study in fragment screening between conventional SPR and dispr using OneStep Injections was performed using a Biacore S1 (GE Healthcare) and Pall ForteBio s Pioneer FE instrument. Biotin-tagged multidomain non-kinase phosphoribosyl transferase (biotinylated during expression using the Avitag system) was captured in high capacity on a biosensor coupled with NeutrAvidin (Pierce). 384 fragments were prepared in assay buffer containing % DMSO to a fragment concentration of 1 µm. Buffer and positive control injections were performed every 16 assay cycles. On the Pioneer FE system all samples were injected using OneStep Injections at a flow rate of 2 µl/min and a dissociation time of 1 sec. Experimental analyses were performed at Genentech in South San Francisco (a member of Roche Group). The Biacore S1 was used to screen the same compounds against the target using the conventional fixed concentration injection (FCI) method. The Pioneer FE system data was reduced and fit with a real-time Langmuir isotherm model using Qdat software. 2

FBDD WITH ONESTEP AND NEXTSTEP INJECTION METHODOLOGIES RESULTS The data generated between the two platforms revealed identical compound hits. Hits were identified using a box-whisker analysis of the LOESS normalized data as previously described 1. In addition, the assay time for the primary screens is comparable. However, while the data from the Biacore S1 is used only for the identification of the fragment hits, the data from the Pioneer FE system are ready for K D analysis. Moreover, the scatter data around the baseline (high scatter renders it difficult to accurately determine hits) shown in the Figure 3 and 4 inset is lower in the Pioneer FE system data (Figure 3 inset) than in the Biacore S1 presumably due to less exposure of the biosensor surface to high compound concentrations. The number of compounds whose binding signals exceed the control response is higher in the Biacore S1 (Figure 4 inset), again presumably due to lower exposure time of the high concentration samples to the biosensor surface in the Pioneer FE system. 8 7 6 4 3 7 6 4 3 2 1-1 1 1 2 2 3 3 4 Injection 2 1 2 3 4 6 Figure 3: OneStep assay primary screening results using Pall ForteBio s Pioneer FE system. The positive control compound was run in 16 replicates and is shown in blue. The inset shows the equilibrium response of each fragment versus assay cycle number with the control compound s 16 replicates connected in blue. 3

Application Note 21 18 16 14 12 1 8 6 4 16 14 12 1 8 6 4 2 1 1 2 2 3 3 4 Injection 2 1 2 3 4 6 7 Figure 4: Fixed concentration injection (FCI) primary screening results using the Biacore S1. Positive control compound is shown in blue with 16 replicates. The inset shows the equilibrium response of each fragment versus assay cycle number with the control compound s 16 replicates shown in blue. ADVANTAGE OF ONESTEP INJECTIONS In conventional SPR analysis, a standard injection (FCI) provides a flow of uniform analyte concentration. The Pioneer FE system is also capable of performing these standard injections. However, the Pioneer FE system differentiates itself from conventional SPR by diffusing the compound solution into a moving stream of buffer to create a sample concentration gradient during OneStep Injections. These features make it possible to vary the analyte concentration during the sample injection. Using this dynamic approach, an analyte titration of three orders of magnitude can be recorded in one continuous injection. There is no need to prepare a full dilution series as is the case with other SPR instrumentation because OneStep Injections actively test analyte concentrations sufficient to fully characterize kinetic and affinity interactions (Figure ). In a typical fragment screen, both conventional FCI and OneStep Injections confirm similar hits (Figures 6 and 7). However, as stated previously, active fragment candidates are identified directly from the primary screen in data generated using the OneStep method. Also, less scatter is readily visible in data generated using OneStep Injections, thus making the decision of which fragments to work with further downstream that much easier. A B 1 8 6 4 2 4 4 3 3 2 2 1 1 1 2 3 4 2 3 4 6 7 8 9 1 Figure : Control compound binding the target. (A) A six-point FCI assay with kinetic model fit to the data in orange. (B) A OneStep assay with kinetic model fit to the data in orange. The time to collect these data was 2 minutes on the Biacore S1 or 4 minutes on Pioneer FE system. OneStep Injections are capable of rapidly delivering kinetic rate and affinity constants similar to the classical approach. 4

FBDD WITH ONESTEP AND NEXTSTEP INJECTION METHODOLOGIES 1 1 8 6 4 2 8 6 4 2 2 4 6 8 1 Run order 2 4 6 8 1 Run order Figure 6: 1 fragments tested on the Pioneer FE system using OneStep Injection (left) and the Biacore S1 (right). Data scaled according to fractional binding occupancy. There is less apparent scatter in the Pioneer system experiment suggesting a more stable target environment. 1 % Surface Saturation Biacore S1 1 8 6 4 2-2 -4-6 -4-2 2 4 6 8 1 % Surface Saturation Pioneer FE System Figure 7: Similar sets of confirmed hits (colored squares) would be selected by both the Biacore S1 and the Pioneer FE system, but OneStep data gave K D information directly from the screen. Analyte Fraction.8.6.4.2 1 1 Component A Component B Figure 8: An illustration of NeXtStep Injections. Rapid dispersion of two analyte components forming a sigmoidal concentration gradient. NEXTSTEP INJECTION TECHNIQUE IN FBDD COMPETITION ASSAYS Competition assays are very useful in drug discovery. They allow for the ability to find site-selective binders directly by confirming the location(s) of the binding site of a specific compound. The Pioneer FE system s NeXtStep Injection technology has the unique ability to determine full kinetics and affinity in the presence of a competitor. Using a rapid dispersion process (non-taylor dispersion), two sample components are dispersed and injected over a biosensor surface. Figures 8 and 9A C show the experimental setup of a NeXtStep competition assay. In summary, a two-part experimental design is demonstrated where fragments are injected using the NeXtStep technique in the presence and absence of constant control concentration. Blank NeXtStep Injections then consist of either buffer-only or control analyte-only to subtract the respective background signal. Like OneStep Injections, NeXtStep Injections enable full kinetic analysis in single competition injection and competition is clearly seen as a lack of or reduction in binding in the presence of the competitor. A single NeXtStep Injection covers a wide analyte concentration range with one dissociation and is used to determine full kinetics and affinity data in the presence of a competitor.

Application Note 21 A Relative Concentration B 2. 2. 1. 1.. - 1 2 NEXTSTEP DIRECT COMPETITION FRAGMENT ASSAY To demonstrate the NeXtStep Injection technique on the Pioneer FE system, carbonic anhydrase II (CAII) was immobilized on a COOHV sensor chip via amine coupling and the Pioneer FE system was primed in HEPES buffered saline, ph 7.4, with.% Tween-2 (HBST). 24 fragment actives were previously identified from the Maybridge Ro3 1, compound library using the Pioneer FE system and its integrated actives selection. These fragments were prepared in two sample solutions, one in buffer and another in buffer with 1 µm furosemide. NeXt- Step Injections ( µl/min) were performed on each sample by dispersing the sample solutions with buffer (Figure 1A) and the furosemide solutions with 1 µm furosemide (Figure 1B). Control injections of buffer and furosemide were also performed for double referencing. Data analysis was performed using Qdat software and results are shown in Figures 1 13. 2. Relative Concentration 2. 1. 1.. - 1 2 A 2 1 1 C 1 1 2 1.2 Relative Concentration 1..8.6.4.2 B 2 1 1-1 2 Figure 9: Competition NeXtStep assay illustrated with real-time concentration graphs. (A) NeXtStep Injection control and analyte + control which shows the binding of control plus a gradient dispersing of analyte binding. (B) Control only NeXtStep Injection which is the reference (blank) for Figure 9A. (C) By subtracting Figure 9B from Figure 9A, constant concentration of analyte only is left and is shown in Figure 9C. 1 1 2 Figure 1: NeXtStep Injections of fragment actives binding CAII in the (A) absence and (B) presence of furosemide using Pioneer FE. 6

FBDD WITH ONESTEP AND NEXTSTEP INJECTION METHODOLOGIES 1 1 1 1 1 1-1 1 2-1 1 2-1 1 2 Figure 11: Fragments with a unique binding site show an unchanged response in the presence (blue curves) and absence (black curves) of a control molecule. K D data derived from a single NeXtStep Injection. 1 1 1 1 1 1-1 1 2-1 1 2-1 1 2 Figure 12: Fragments which bind active site show a decreased response with NeXtStep Injections in the presence of the control allowing for prompt identification. As previously stated, the Pioneer platform with NeXtStep Injection technology has the unique ability to determine full kinetics and affinity of a fragment in the presence of a competitor from a single injection. Figure 11 shows one binding mode represented by comparing the binding of an analyte in the presence and absence of a control. When a fragment binds the target protein away from the active site, the binding will be unchanged in the presence of the control. Fragment actives are therefore promptly binned without further screening cycles typical of conventional SPR systems. In a second binding mode, when a fragment binds to the active site, the NeXtStep response will decrease in the presence of the control. The decrease in signal is readily identifiable in the Figure 12 examples. Further screening becomes a rate-limiting and unnecessary step. What happens when fragment binding cooperates with the control? In a third binding mode shown in Figure 13, fragments which display cooperative or non-competitive binding with the control will show an increased NeXtStep binding response in the presence of the control. The NeXtStep competition assay on the Pioneer FE system qualitatively identifies the three most common competition binding modes and quantitatively gives competition K D for increased certainty of analyte binding modes. 1 8 4 6 4 2-2 3 2 1-1 1 1 2 1 1 2 Figure 13: Fragments which bind cooperatively or non-competitive binders will show increased binding in the presence of the control. 7

FBDD WITH ONESTEP AND NEXTSTEP INJECTION METHODOLOGIES Application Note 21 CONCLUSION The detection and characterization of fragment binding events is dependent upon ultrasensitive technologies that are well suited to detect interactions of weak affinity and low molecular weight compounds. As demonstrated throughout this application note, in comparison to other SPR-based biosensor technologies, the Pioneer FE system with OneStep Injections has the extraordinary advantage of directly influencing the rate at which fragment screening is accomplished. Content-rich data can be derived from a primary screen, enabling the rapid selection of active fragments. REFERENCES 1 A. M. Giannetti et al. Fragment-Based Drug Discovery, S. Howard, C. Abell, Eds. (Royal Soc. Chem., Cambridge, 21) chap. 2 ACKNOWLEDGMENTS Pall ForteBio would like to thank Dr. Tony Giannetti and his lab at Genentech for the use of their data and for critical input. The OneStep gradient injection method provides K D values from single injections, allowing the Pioneer FE instrument to eliminate secondary screens required in other SPR techniques no other SPR systems have this technology. The Pioneer FE system combines identification and affinity from OneStep Injections with a specificity before the NeXtStep competitive assay to provide rapid and complete evaluation of fragment actives. Pall ForteBio 47661 Fremont Boulevard Fremont, CA 9438 t: 888.OCTET-7 or 6.322.136 Pall ForteBio Europe Harbourgate Business Park Southampton Road Portsmouth, PO6 4BQ, UK t: +44-()23 318 284 www.fortebio.com 8 Pall ForteBio Analytics (Shanghai) Co., Ltd. 917 Halley Road, Bldg 4 Zhangjiang High Tech Park Shanghai, China 2123 t: +86-21-132387 216, Pall Corporation. Pall,, ForteBio, dispr, OneStep and NeXtStep are trademarks of Pall Corporation. indicates a trademark registered in the USA and indicates a common law trademark. AN-41-23 Rev A