Influence of First Shape Factor in Behaviour of Rubber Bearings Base Isolated Buildings.

Similar documents
Hand Calculations of Rubber Bearing Seismic Izolation System for Irregular Buildings in Plane

SEISMIC BASE ISOLATION

Sabah Shawkat Cabinet of Structural Engineering Walls carrying vertical loads should be designed as columns. Basically walls are designed in

Soil-Structure Interaction in Nonlinear Pushover Analysis of Frame RC Structures: Nonhomogeneous Soil Condition

Codal Provisions IS 1893 (Part 1) 2002

Multi Linear Elastic and Plastic Link in SAP2000

Address for Correspondence

3. Stability of built-up members in compression

Title. Author(s)DONG, Q.; OKAZAKI, T.; MIDORIKAWA, M.; RYAN, K.; SAT. Issue Date Doc URL. Type. Note. File Information BEARINGS

Finite Element Modelling with Plastic Hinges

DETERMINATION OF PERFORMANCE POINT IN CAPACITY SPECTRUM METHOD

Analysis Of Seismic Performance Of Fps Base Isolated Structures Subjected To Near Fault Events

TABLE OF CONTENTS SECTION TITLE PAGE 2 PRINCIPLES OF SEISMIC ISOLATION OF BRIDGES 3

COLUMN INTERACTION EFFECT ON PUSH OVER 3D ANALYSIS OF IRREGULAR STRUCTURES

HIGHLY ADAPTABLE RUBBER ISOLATION SYSTEMS

INELASTIC SEISMIC DISPLACEMENT RESPONSE PREDICTION OF MDOF SYSTEMS BY EQUIVALENT LINEARIZATION

This Technical Note describes how the program checks column capacity or designs reinforced concrete columns when the ACI code is selected.

Lecture 4 Dynamic Analysis of Buildings

Strength Degradation in Lead-Rubber Bearings during a Long-duration Earthquake

INFLUENCE OF FRICTION PENDULUM SYSTEM ON THE RESPONSE OF BASE ISOLATED STRUCTURES

Vertical acceleration and torsional effects on the dynamic stability and design of C-bent columns

DYNAMIC ANALYSIS OF PILES IN SAND BASED ON SOIL-PILE INTERACTION

ANALYSIS OF HIGHRISE BUILDING STRUCTURE WITH SETBACK SUBJECT TO EARTHQUAKE GROUND MOTIONS

ENERGY DIAGRAM w/ HYSTERETIC

Seismic design of bridges

COLUMN BASE WEAK AXIS ALIGNED ASYMMETRIC FRICTION CONNECTION CYCLIC PERFORMANCE

International Journal of Advance Engineering and Research Development

Effects of Damping Ratio of Restoring force Device on Response of a Structure Resting on Sliding Supports with Restoring Force Device

Pushover Seismic Analysis of Bridge Structures

Dr.Vinod Hosur, Professor, Civil Engg.Dept., Gogte Institute of Technology, Belgaum

Comparison of Structural Models for Seismic Analysis of Multi-Storey Frame Buildings

Structural Steelwork Eurocodes Development of A Trans-national Approach

Nonlinear static analysis PUSHOVER

Model tests and FE-modelling of dynamic soil-structure interaction

THE EC3 CLASSIFICATION OF JOINTS AND ALTERNATIVE PROPOSALS

HIERARCHY OF DIFFICULTY CONCEPT: COMPARISON BETWEEN LINEAR AND NON LINEAR ANALYSES ACCORDING TO EC8

Comparative study between the push-over analysis and the method proposed by the RPA for the evaluation of seismic reduction coefficient

Numerical Modelling of Dynamic Earth Force Transmission to Underground Structures

INELASTIC RESPONSES OF LONG BRIDGES TO ASYNCHRONOUS SEISMIC INPUTS

CAPACITY DESIGN FOR TALL BUILDINGS WITH MIXED SYSTEM

Chapter (6) Geometric Design of Shallow Foundations

Design Calculations & Real Behaviour (Hambly s Paradox)

TORSIONAL EFFECTS AND REGULARITY CONDITIONS IN RC BUILDINGS

Seismic Performance of RC Building Using Spectrum Response and Pushover Analyses

A Mathematical Formulation to Estimate the Fundamental Period of High-Rise Buildings Including Flexural-Shear Behavior and Structural Interaction

Influence of Modelling Issues on Nonlinear Static Seismic Analysis of a Regular 3D Steel Structure. A. Belejo; R. Bento - Maio de

D : SOLID MECHANICS. Q. 1 Q. 9 carry one mark each. Q.1 Find the force (in kn) in the member BH of the truss shown.

ΙApostolos Konstantinidis Diaphragmatic behaviour. Volume B

Design of reinforced concrete sections according to EN and EN


Simple Method for Analysis of Tube Frame by Consideration of Negative Shear Lag

RESPONSE ANALYSIS STUDY OF A BASE-ISOLATED BUILDING BASED

A METHOD OF LOAD INCREMENTS FOR THE DETERMINATION OF SECOND-ORDER LIMIT LOAD AND COLLAPSE SAFETY OF REINFORCED CONCRETE FRAMED STRUCTURES

COMPRESSION AND BENDING STIFFNESS OF FIBER-REINFORCED ELASTOMERIC BEARINGS. Abstract. Introduction

Estimation of damping capacity of rubber vibration isolators under harmonic excitation

DYNAMIC RESPONSE OF EARTHQUAKE EXCITED INELASTIC PRIMARY- SECONDARY SYSTEMS

Harmonized European standards for construction in Egypt

A. Belejo, R. Bento & C. Bhatt Instituto Superior Técnico, Lisbon, Portugal 1.INTRODUCTION

EAS 664/4 Principle Structural Design

The effects of the accidental torsional eccentricity on the seismic behaviour of building structures

five Mechanics of Materials 1 ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS SUMMER 2017 lecture

DEFORMATION CAPACITY OF OLDER RC SHEAR WALLS: EXPERIMENTAL ASSESSMENT AND COMPARISON WITH EUROCODE 8 - PART 3 PROVISIONS

Prof. B V S Viswanadham, Department of Civil Engineering, IIT Bombay

Alireza Mehdipanah BEHAVIOUR OF BUILDINGS FEATURING TRANSFER BEAMS IN THE REGIONS OF LOW TO MODERATE SEISMICITY

SIMPLIFIED METHOD FOR PREDICTING DEFORMATIONS OF RC FRAMES DURING FIRE EXPOSURE

A Nonlinear Static (Pushover) Procedure Consistent with New Zealand Standards

Seismic Assessment of a RC Building according to FEMA 356 and Eurocode 8

Design of Earthquake-Resistant Structures

MATHEMATICAL MODEL OF DYNAMIC VIBRATION ABSORBER-RESPONSE PREDICTION AND REDUCTION

FINITE GRID SOLUTION FOR NON-RECTANGULAR PLATES

STATIC NONLINEAR ANALYSIS. Advanced Earthquake Engineering CIVIL-706. Instructor: Lorenzo DIANA, PhD

STUDY ON THE RESPONSE OF ELASTOMERIC BEARINGS WITH 3D NUMERICAL SIMULATIONS AND EXPERIMENTAL VALIDATION

NUMERICAL SIMULATION OF THE INELASTIC SEISMIC RESPONSE OF RC STRUCTURES WITH ENERGY DISSIPATORS

SEISMIC RESPONSE OF SINGLE DEGREE OF FREEDOM STRUCTURAL FUSE SYSTEMS

Nonlinear Analysis of Reinforced Concrete Bridges under Earthquakes

on the figure. Someone has suggested that, in terms of the degrees of freedom x1 and M. Note that if you think the given 1.2

OS MODELER - EXAMPLES OF APPLICATION Version 1.0. (Draft)

Role of hysteretic damping in the earthquake response of ground

Members Subjected to Torsional Loads

A Modified Response Spectrum Analysis Procedure (MRSA) to Determine the Nonlinear Seismic Demands of Tall Buildings

Ph.D. Preliminary Examination Analysis

Introduction to structural dynamics

5.4.3 Centre of stiffness and elastic displacements of the diaphragm

Stability of Simply Supported Square Plate with Concentric Cutout

ENVELOPES FOR SEISMIC RESPONSE VECTORS IN NONLINEAR STRUCTURES

9.5 Compression Members

3.4 Analysis for lateral loads

ENG1001 Engineering Design 1

FIXED BEAMS IN BENDING

NON-LINEAR ANALYSIS OF SOIL-PILE-STRUCTURE INTERACTION UNDER SEISMIC LOADS

IMPROVING LATERAL STIFFNESS ESTIMATION IN THE DIAGONAL STRUT MODEL OF INFILLED FRAMES

5. Buckling analysis of plane structures: simplified methods

Christian Linde Olsen Griffith University, Faculty of Engineering and Information Technology, Gold Coast Campus.

Slenderness Effects for Concrete Columns in Sway Frame - Moment Magnification Method (CSA A )

Effect of eccentric moments on seismic ratcheting of single-degree-of-freedom structures

Lecture-08 Gravity Load Analysis of RC Structures

A Comparative Study on RC Frame Structure Considering Lead Rubber Bearing and Triple Friction Pendulum Bearing

Structural Steelwork Eurocodes Development of A Trans-national Approach

MODELLING DAMAGE AND PROGRESSIVE COLLAPSE OF FRAMES USING A GAUSSIAN SPRINGS BASED APPLIED ELEMENT METHOD

Verification of a Micropile Foundation

Transcription:

ISSN (Online) 2347-327 Influence of First Shape Factor in Behaviour of Rubber Bearings Base Isolated Buildings. Luan MURTAJ 1, Enkelejda MURTAJ 1 Pedagogue, Department of Structural Mechanics Faculty of Civil Engineering Polytechnic University of Tirana Tirana, ALBANIA email: lmyrtaj@yahoo.com Abstract Rubber bearings isolators are widely used in base isolation system for different kind of structures. Their characteristics depend on components properties (rubber and shims), displacement magnitude, and first and second shape factor. For a given materials, the second shape factor which gave the ratio of isolator diameter to total rubber height, doesn t vary too much. In opposite, the first shape factor given as S 1 = D / 4t (where D and t denotes the isolator diameter and single rubber layer thickness), have a wide range and influence the isolator properties by its quadratic value. By increasing this factor we get a very high modulus of elasticity for the combined materials, which yield in very high vertical stiffness and critical axial load for the isolator unit. The horizontal stiffness is sensitive to ratio of design axial load to critical load and decrease rapidly when this ratio increases. From the other side the critical load depend on shear strain. The reduction in horizontal stiffness yield in higher shear strain and a further reduction in critical load and so on. In this study will be shown from quantitative side of view the influence of first shape factor to the above properties and performance of isolation system under strong motion earthquake. The fast nonlinear and direct integration analyses will be used to observe the performance of a base isolated building with different first shape factors of isolators. Keywords-isolation system, shape factor, strong motion, critical load, reduced stiffness I. INTRODUCTION In this study will be show the behaviour of base isolated building, with laminated rubber bearings, for different values of first shape factor. For this reason a seven storey regular in-plane building is chose with a frame structure. The floor weight is assumed equal to 12 kn/m 2, which is rather big, just to amplify the response of the structure. A 5% accidental in-plane eccentricity is taken according to Eurocode-8 provisions. The building is subjected to a strong motion earthquake presented by ground accelerogram acting in one direction. Attempting a target effective period of 2.5 seconds and 1.5 desired shear strain, the isolators units with specific second shape factors are chose to support the structures under each column. Then the isolators are taken from no lamination to highly laminate. The superstructure is simplified by modelling each storey with linear link element, assuming that the structures will remain in linear elastic range. The link element have three degree of freedom, horizontal stiffness in X and Y direction and rotational stiffness in Z direction. Modelling of superstructure with link elements reduce drastically the amount of computational calculation and adequately present the whole structure. As concern to rubber isolators, they are modelled with nonlinear link element with two degree of freedom. During the analyses the axial force acting on isolators are invariant and the effective horizontal stiffness are reduced by reduction of critical stresses for different level of shear strains. A variation of axial loads can be included as well with a satisfactory approximation. The performance of base isolated building is carry out by nonlinear time history analyses with time step of.2 seconds which is a satisfy threshold to catch the response of every single isolator unit. At the end, based on the analyses results, the proper conclusions are given. II. BUILDING PARAMETERS AND MODELING The building consists of seven rectangular storeys with equal height of 3.2m as shown in figure 1. According to Eurocode-8 provisions, the building is classified regular in-plane and a 5% accidental eccentricity is assume. The weight for each floor is taken uniformly distributed with intensity of 12kN/m 2. Mass properties are attached to a special join with three degree of freedom; mass in X, Y and rotational about Z axis. The possible position of the mass centre is given by the hatch area. Because the structure is symmetric, the initial centre of rigidity corresponds with the geometric centre of the building plan. As we will see, this point is not fixed for the isolation system for different level of deformation. For each isolator unit the initial axial static loads are calculated based on respectively supported area. Based on preliminary design, the external columns are taken with square cross-section 5x5cm and inner columns 6x6cm. The design of superstructure is not subject of this study [2] [4]. IJIRSE/Vol 3. Iss.3/ Page 58

16.6[m] 8.[m] 8.[m] 1.66[m] (IJIRSE) International Journal of Innovative Research in Science & Engineering ISSN (Online) 2347-327 A B C D E F G 1176 kn 1176 kn 3 M E 474 kn 474 kn 474 kn 474 kn 474 kn CM R CR 2 E 1 4.26[m] 1176 kn 1176 kn 1 7.[m] 7.[m] 7.[m] 42.6[m] 7.[m] 7.[m] 7.[m] Figure 1. Building plan view The elastomeric isolators are modelled with rubber isolator standard link element in Sap computer program for laminated rubber bearings and multi-linear plastic links for no laminated isolator. For each shape factor the horizontal capacity of isolator is modelled with tri-linear curve in function of horizontal displacement. Both horizontal degrees of freedom are modelled with nonlinear behaviour. The finite element model for computational analyses is given in figure 2. The special points with number 5 to 57 are placed 2.13 meters to the left of building centre. To these points are attached the mass of each storeys level according to three degrees of freedom respectively; mass in X & Y direction and mass moment of inertia about Z axis [7]. Figure 2. Finite elements model The parameters for link elements presenting the building s storeys are derived as below. Horizontal stiffness in X & Y direction K H = k i with ki = 12EI i /H 3 (1) Torsional stiffness in Z direction K RZ = (k i x 2 i + k i y 2 i ) (2) where E module of elasticity for concrete material I i moment of inertia for column cross-section H clear height of column for each storey x i, y i coordinates of columns from rigidity centre of the storey IJIRSE/Vol 3. Iss.3/ Page 59

ISSN (Online) 2347-327 The stiffness of girders and slabs is assume infinite and so for each level storey are taken three degree of freedoms, two laterals and one torsional. Adequate constrains are put for each storey level and among the link elements modelling the isolator units. The rubber compound for the production of elastomeric isolators used in our study is chosen the MVBR-468 (X.4R) produced by Bridgestone with certification on December 212. This material exercises a high dumping ratio and normally there is no need of additional dumper [6]. The effective dynamic shear modulus G eff and the equivalent dumping ζ are function to shear strain. In our case the values for these parameters are given by the producer at shear strain γ=1 respectively G eff =.392 MPa and ζ=22%. Both parameters are sensitive to shear strains and their relationships to γ are given from the following expressions. For small values of γ the elastomeric isolator is stiff enough to avoid excessive displacements under low dynamic intensity of external loads such as wind [6]. G eff ( ) =.54 4 -.416 3 + 1.192 2 1.583 + 1.145 (3) eff ( ) = -.6 3 +.18 2.8 +.216 (4) These values are true for no axial stress applied in isolator unit. In our case of study, the axial force can t be neglected and proper corrections must be done when calculating the lateral capacities of isolator unite. Firstly we select the rubber bearing isolators depending on vertical static loads and the desire effective period of 2.5 s and target shear strain γ=1.5. The desired effective stiffness can be derived from the following expression [1]: k eff = 4 * 2 * m / T eff 2 where m denotes the seismic mass supported by the isolator unit equal to N/g. N is the static compression axial load acting on isolator unit. Two isolators with different vertical load capacity will be chosen, five isolator units with bearing axial load greater or equal to 474 kn (group A) and sixteen isolator units with bearing capacity greater than (group B). Grouping the isolators make them more economical and easy to implement in site. The desired effective stiffness are respectively: k eff (A) = 4 * 2 * 48 / 2.5 2 = 329 kn/m k eff (B) = 4 * 2 * 24 / 2.5 2 = 1514 kn/m The effective stiffness can be calculated using the simplify formula considering only the shear deformation: (5) k eff = G eff * / t r (6) For γ=1.5 we have the effective shear modulus G eff = 322 kpa and assuming the total height of the rubber t r =16mm, the cross-section area of the isolator result: A (A) = k eff (A) * t r / G eff = 329 *.16 / 322 = 1.551 m 2 choosing the diameter D = 1.3m with A (A) = 1.3249 m2 and k eff (A) = 2666.4 kn/m A (B) = k eff (B) * t r / G eff = 1514 *.16 / 322 =.7523 m 2 choosing the diameter D = 1.m with A (B) =.7849 m2 and k eff (B) = 1579.6 kn/m The effective stiffness of isolation system for horizontal directions is calculated as sum of single devices. K eff = 5 * k eff (A) + 16 * k eff (B) = 5 * 2666.4 + 14 * 1579.6 = 35446.4 kn/m. The effective period of isolation system is defined from the following expression: T eff = 2 * * (M / K eff ) = 2 * * (5754 / 35446.4) = 2.53s (4) The above values correspond to unloaded isolators with axial force. The values, such as horizontal stiffness, are a function of critical vertical load, axial stress and shear strain. The critical load depends on first and second shape factors of isolator unit. The values of critical load and shape factors for the assumed rubber material are given from the following expressions [6]: K eff,h = K eff,h [1- ( sd / cr ) 2 ] (7) cr ( ) = cr * (1 - / S 2 ) (8) cr = c * /4 * (G eq * E b ).5 * S 2 (9) E b = E cr (1 + 2/3 * * S 1 2 ) / {1 + E cr (1 + 2/3 * * S 1 2 ) / E } (1) IJIRSE/Vol 3. Iss.3/ Page 6

ISSN (Online) 2347-327 sd axial stress at isolator unit cr ( ) critical stress at strain cr critical stress at = c =.88 (1-.7(5 - S 2 )) for S 2 < 5 or c =.88 otherwise S 1 = D / (4 * t) first shape factor S 2 = D / t r second shape factor E cr = 3 * G eq,( =1) critical modulus E = 13 MPa bulk modulus =.223 isolator coefficient correction factor For a given isolator unit the second shape factor is invariant. The first shape factor can varied in wide range and influence the critical stress by its quadratic value. To observe the influence of first shape factor let analyse the case of no lamination till a thickness of rubber layer equal to 8mm. The properties of isolator are given in tabular data in the table 1 & table 2. TABLE I. ISOLATOR CHARACTERISTICS OF GROUP A Isolator unit Type A Nr. of layers 1 2 4 8 12 16 2 Layer s thickness (mm) 16 8 4 2 13.3 1 8 First shape factor 2.3 4.6 8.13 16.25 24.44 32.5 4 S 1 Critical stress at = 791 116 1899 3591 5277 6828 8296 TABLE II. ISOLATOR CHARACTERISTICS OF GROUP B Isolator unit Type B Nr. of layers 1 2 4 8 12 16 2 24 Layer s thickness (mm) 16 8 4 2 13.3 1 8 6.7 First shape factor 1.56 3.12 6.25 12.5 18.75 25 31.25 37.3 S 1 Critical stress at = 571 7423 123 223 3281 4269 523 681 For each isolator unit we calculate the design stress caused by the vertical load. Increasing the shear strains from zero till to limit values, the shear capacity curves will be built. The capacity shear force will be calculated from the following formulas [2]: For isolators of group A, the axial stresses are equal to Sd,A = 474 / 1.3249 = 355 kn/m 2 V Rd, H = K eff,h * * t r (1) For isolators of group B, the axial stresses for corner isolators and the remain ones are equal to Sd,Bc = 1176 /.7849 = 1498 kn/m 2 Sd,B = 2352 /.7849 = 2997 kn/m 2 Keeping the axial stresses constant and reducing the critical stresses for variation of shear strain the horizontal capacity curves are built for different values of first shape factor. The graphical presentation is given in figure 3 & figure 4. Also we make a nonlinear analysis without the reduction of horizontal stiffness. In this case the isolators are modelled with a built-in rubber isolator link element as describe in Sap Manual. Neglecting the reduction of horizontal stiffness, as we will see, yield in lower base displacements and in higher base shear forces. IJIRSE/Vol 3. Iss.3/ Page 61

Ground Accel. [m/s2] (IJIRSE) International Journal of Innovative Research in Science & Engineering ISSN (Online) 2347-327 1 1 3 8 6 Horizontal Capacity for Isolators Type-A S1=2.3 S1=4.6 S1=8.13 S1=16.25 S1=24.44 S1=32.5 S1=4 1 1 3 8 6 Tri-linear Horizontal Capacity for Isolators Type-A S1=2.3 S1=4.6 S1=8.13 S1=16.25 S1=24.44 S1=32.5 S1=4.1.2.3.4.5.1.2.3.4.5.6 V Rd,H (Δ) [kn] vs Δ [m] V Rd,H (Δ) [kn] vs Δ [m] Figure 3. Capacity courves for horizontal direction of Type-A isolators 5 3 Horizontal Capacity for Isolators Type-B S1=1.56 S1=3.12 S1=6.25 S1=12.5 S1=18.75 S1=25 S1=37.3 5 3 Tri-linear Horizontal Capacity for Isolators Type-B S1=1.56 S1=3.12 S1=6.25 S1=12.5 S1=18.75 S1=25 S1=37.3 1 1.1.2.3.4.5.1.2.3.4.5.6 V Rd,H (Δ) [kn] vs Δ [m] V Rd,H (Δ) [kn] vs Δ [m] Figure 4. Capacity courves for horizontal direction of Type-B isolators III. COMPUTATIONAL ANALYSES The effect of vertical loads is included in calculation of the lateral capacity curves for each isolator unit. To simulate the lateral loads, the Santa Monica earthquake accelerogram is taken as shown in figure 5. The response of isolated building is done through nonlinear time histories analyses. Two kings of nonlinear THS are performed, fast nonlinear analyzing using the modal values and direct integration. The modal analyses are done using the Ritz vectors including all isolators unit and two lateral acceleration in X and Y direction with target accuracy 99%. Using this approach the FNA and NLDIH gives almost the same results [7]. 1 8 6 4 2 2 4 6 8 Santa Monica Earthquake 1 2 4 6 8 1 12 14 16 18 2 Time [s] Figure 5. Santa Monica earthquake accelerogram IJIRSE/Vol 3. Iss.3/ Page 62

ISSN (Online) 2347-327 From the analyses the translative displacement are taken excludind the rotational degree of freedom to vertical axis. These displacement are given in table 3, and as can be seen the first shape factor influence is not linear. For shape factor over the value 8 there is not a significant change in displacement. This result must not be taken as adequat reminding that the axial load on isolator is kept constant. TABLE III. STOREYS DISPLCEMENT WITHOUT TORSION 2 No axial Storey Level 1 layer 2 layers 4 layers layers load Ground Base Isolation 29.4 24.3 19.3 19.1 13.8 Storey 1 29.6 24.5 19.6 19.4 14.1 Storey 2 29.7 24.8 19.8 19.6 14.2 Storey 3 29.9 24.9 2.1 19.8 14.4 Storey 4 3. 25.1 2.3 2. 14.5 Storey 5 3.1 25.3 2.4 2.2 14.6 Storey 6 3.2 25.4 2.5 2.3 14.6 Storey 7 3.3 25.5 2.6 2.4 14.7 In figure 6 are presented graphically the translative displacements of the base isolation and for each storey. Also there is shown the scheme of plan displacement of base isolation when the torsional degree of freedom is included. 8 7 6 5 4 No Lamination 2 layers 4 layers 2 layers No Axial Load Storeys Displacements max z CM e X R CR M E min 3 E 1 M R 2 1 5 1 15 2 25 3 35 Figure 6. Santa Monica earthquake accelerogram In table 4 are given the maximal and minimal displacements of base isolation system at maximum lateral displacement for different values of first shape factor. At these deformed states the base shear forces and torsional moments to vertical axis are given. The eccentricity is calculated as ratio of torsional moment to base shear force. As it can be seen, the eccentricity is not a fix value and has a wide variation. The magnitude of these variations depends on initial eccentricity, rotational mass moment of inertia, first shape factor, magnitude of axial load on isolator unit, external lateral forces etc. TABLE IV. MAXIMAL AND MINIMAL DISPLACEMENTS. VARIATON OF ECCENTRICITY Nr. Layers max min -z V Y M Z e-x 1 36.2 8.4.38 564 4683 9.25 2 32.6 12.9.27 6389 3693 5.78 4 22.3 16.3.8 7138 5815.81 2 2.4 16.6.5 879 38793 4.8 No axial load 18.6 8.1.14 7796 6557 8.41 IJIRSE/Vol 3. Iss.3/ Page 63

Displacement [m] (IJIRSE) International Journal of Innovative Research in Science & Engineering ISSN (Online) 2347-327 In figure 7 are given the time histories of displacements for the left-corner isolator which expresses higher values of strains. The base isolation system consists of no laminated isolators has larger displacements and there is a lack of restoring force. For the base isolation system with no axial forces in isolator units, the maximal displacement doesn t differ too much with the case of full laminated, but the displacements are dumped faster..3 Maximal Displacements.2.1.1.2.3 no axial load 2 layers 4 layers 2 layers 1 layer.4 2 4 6 8 1 12 14 16 18 2 Time [secocds] Figure 7. Santa Monica earthquake accelerogram In figure 8 are given the histerezis curves for left-corner isolators. It can be clearly seen that the effective stiffness depend directly to the amount of laminated layers and magnitude of axial load. The lack of restoring force can be observed for the no laminated isolator. 6 6 1 layer 6.35.25.15.5.5.15.25.35 2 layers 6.35.25.15.5.5.15.25.35 6 6 4 layers 6.35.25.15.5.5.15.25.35 2 layers 6.35.25.15.5.5.15.25.35 6 6 no axial load 6.35.25.15.5.5.15.25.35 1 layer no axial load 6.35.25.15.5.5.15.25.35 Figure 8. Santa Monica earthquake accelerogram IJIRSE/Vol 3. Iss.3/ Page 64

ISSN (Online) 2347-327 IV. CONCLUSIONS Rubber bearing base isolation system behaviour depends directly by the first shape factor. In accordance to the magnitude of axial load acting upon the isolator unit, certain value of first shape factor must not be allowed. In this study the axial load are taken as invariant and the minimum acceptable value for the shape factor is around 1. In reality the axial load vary during the time history due to overturning moment, especially in peripheral isolator units and so a higher value for first shape factor is required. Other requirements for vertical stiffness might yield in higher value of shape factor. For low values of firs shape factor the displacements increase causing large shear strain. In such strains the restoring force is not stable and can yield in unit failure. Even in symmetrical building, the existence of accidental eccentricity of mass, yield in considerable torsional moment. This torsional moment induces different displacement in isolator units and hence the isolator units manifest different effective stiffness. This phenomenon increase the initial eccentricity and gives a higher torsion, so isolation system exercise additional displacement till the internal equilibrium is achieved. The eccentricity vary during the time history and depend from many parameters such as building geometry, initial eccentricity, magnitude of external lateral force, but is more sensitive for low values of lamination. Higher values of first shape factor give a stiffer base isolation system. Although the additional energy transited in superstructure is not considerable, only few additional drifts can result in first floor of superstructure. In this study the fluctuation of rubber properties due to environmental condition such as temperature oscillations or time depended properties from aging are not consider. The lamination gives a good confinement to rubber and reduces the degradation of the material. This is another issue in evaluation of first shape factor in life durability of base isolation systems. REFERENCES [1] Farzad Naeim and James M. Kelly, Design of Seismic Isolated Structures From Theory to Pratice. John Wiley & Sons, Inc, 1999 [2] CEN, Eurocode 8. Design of structures for earthquake resistance Part 1: General rules, seismic action and rules for buildings. pren 1998-1:3E, 3. [3] Anil K. Chopra, Dynamic of Structures Theory and Application to Earthquake Engineering. Prentice-Hall, 1995. [4] Murtaj L., Murtaj E., Hand Calculations of Rubber Bearing Seismic Isolation System for Irregular Buildings in Plane, International Journal of Innovative Research in Science & Engineering, Volume 3 Issue 2, Pg. 17-24, ISSN 234-327, 215. [5] Murtaj L., Softa F., First Seismic Isolated Building in Albania, 14 th Europian Conference on Earthquake Engineering, Ohrid, Macedonia, 21. [6] Bridgestone Corporation, Seismic isolation product line-up, Construction Materials Sales & Marketing Department, June 213. [7] SAP, Integrated Finite Element Analysis and Design of Structures, Analysis Reference, Vol. 1&2, Computer and Structure, Inc, Berkeley, California, USA, 9. IJIRSE/Vol 3. Iss.3/ Page 65