Effect of Oil on Flow Boiling Heat Transfer and Flow Patterns of CO2 in 11.2 mm Horizontal Smooth and Enhanced Tube

Similar documents
Boiling Heat Transfer and Pressure Drop of R1234ze(E) inside a Small-Diameter 2.5 mm Microfin Tube

Heat Transfer of Condensation in Smooth Round Tube from Superheated Vapor

Oil Retention and Pressure Drop of R134a, R1234yf and R410A with POE 100 in Suction Lines

Characteristics of Flow Boiling Heat Transfer of Sub-Critical CO2 in Mini-Channels With Micro- Fins

Two-Phase Refrigerant Distribution in a Micro- Channel Manifold

Developing Two-Phase R134a Flow after an Expansion Valve in an 8.7mm Tube

Developing Mist-Annular Flow of R134a/PAG 46 Oil on Inclined Tubes at Compressor Discharge

Evaporation Heat Transfer Coefficients Of R-446A And R-1234ze(E)

Uncertainty Analysis on Prediction of Heat Transfer Coefficient and Pressure Drop in Heat Exchangers Due to Refrigerant Property Prediction Error

Experimental investigation on up-flow boiling of R1234yf in aluminum multi-port extruded tubes

In Tube Evaporation Heat Transfer of Refrigerant Mixtures

EXPERIMENTAL ANALYSIS OF R-134a FLOW CONDENSATION IN A SMOOTH TUBE

Condensation and Evaporation Characteristics of Flows Inside Three Dimensional Vipertex Enhanced Heat Transfer Tubes

Pratik Shashikant Deokar Auburn University, Department of Mechanical Engineering, Auburn, AL, USA,

FORCE FED BOILING AND CONDENSATION FOR HIGH HEAT FLUX APPLICATIONS

Transient pressure drop correlation between parallel minichannels during flow boiling of R134a

IHTC DRAFT MEASUREMENT OF LIQUID FILM THICKNESS IN MICRO TUBE ANNULAR FLOW

Characteristics of CO2 Transcritical Expansion Process

An Experimental Study On Condensation Of R134a In A Multi-Port Extruded Tube

R134a Flow Boiling inside a 4.3 mm ID Microfin Tube

A Novel Model Considered Mass and Energy Conservation for Both Liquid and Vapor in Adsorption Refrigeration System.

R32 Heat Transfer Coefficient During Condensation In A Mini-Channel Multiport Tube

Paper # 2098 author: Pratik S. Deokar Auburn University

Principles of Food and Bioprocess Engineering (FS 231) Problems on Heat Transfer

THE CHARACTERISTICS OF BRAZED PLATE HEAT EXCHANGERS WITH DIFFERENT CHEVRON ANGLES

Stratified Flow Condensation of CO 2 in a Tube at Low Temperatures Pei-hua Li 1, a, Joe Deans 2,b and Stuart Norris 3,c

a. Key Laboratory of Efficient Utilization of Low and Medium Grade Energy, MOE, Tianjin University, Tianjin , China

An experimental study of flow pattern and pressure drop for flow boiling inside microfinned helically coiled tube

CONDENSATION HEAT TRANSFER COEFFICIENT CORRELATION BASED ON SLIP RATIO MODEL IN A HORIZONTAL HEAT EXCHANGER

Mathematical Modelling for Refrigerant Flow in Diabatic Capillary Tube

Development of a one-dimensional boiling model: Part I A two-phase flow pattern map for a heavy hydrocarbon feedstock

DETERMINATION OF R134A S CONVECTIVE HEAT TRANSFER COEFFICIENT IN HORIZONTAL EVAPORATORS HAVING SMOOTH AND CORRUGATED TUBES

Investigations Of Heat Transfer And Components Efficiencies In Two-Phase Isobutane Injector

Onset of Flow Instability in a Rectangular Channel Under Transversely Uniform and Non-uniform Heating

InterPACKICNMM

Measurement of the performances of a transparent closed loop two-phase thermosyphon

GRAVITY EFFECT ON THE DISTRIBUTION OF REFRIGERANT FLOW IN A MULTI-CIRCUITED CONDENSER

Experimental Study on Liquid Film Thickness of Annular Flow in Microchannels

Innovative Minichannel Condensers and Evaporators for Air Conditioning Equipment

ME 402 GRADUATE PROJECT REPORT ACTIVE BATTERY COOLING SYSTEM FOR ALL-ELECTRIC VEHICLES JINGWEI ZHU

Numerical Simulation on Heat Transfer Phenomena in Microchannel Evaporator of A CO 2 Air Conditioning System

Condensation Heat Transfer of Pure Refrigerants in Microfin Tubes

Minhhung Doan, Thanhtrung Dang

Analysis Of Void Fraction In Microchannels

FLOW BOILING HEAT-TRANSFER IN PLATE MICRO- CHANNEL HEAT SINK

Heat Transfer From the Evaporator Outlet to the Charge of Thermostatic Expansion Valves

CFD Simulation and Experimental Study on Airside Performance for MCHX

Evaporation Heat Transfer and Pressure Drop of Refrigerant R-410A Flow in a Vertical Plate Heat Exchanger

Heat transfer coefficient of near boiling single phase flow with propane in horizontal circular micro channel

Semi-Empirical 3D Rectangular Channel Air Flow Heat Transfer and Friction Factor Correlations

Thermodynamic Properties of Low-GWP Refrigerant for Centrifugal Chiller

Two Phase Pressure Drop of CO2, Ammonia, and R245fa in Multiport Aluminum Microchannel Tubes

Forced Convective Boiling Heat Transfer in Microtubes at Low Mass and Heat Fluxes

Continuous vs. pulsating flow boiling. Part 2: Statistical comparison using response surface methodology

Flow Boiling Heat Transfer in Microchannel Cold Plate Evaporators for Electronics Cooling

HEAT TRANSFER CAPABILITY OF A THERMOSYPHON HEAT TRANSPORT DEVICE WITH EXPERIMENTAL AND CFD STUDIES

Investigation of Thermal-Hydraulic Characteristics of Pillow Plate Heat Exchangers Using CFD

SEM-2017(03HI MECHANICAL ENGINEERING. Paper II. Please read each of the following instructions carefully before attempting questions.

Effect of Coiled Capillary Tube Pitch on Vapor Compression Refrigeration System Performance.

Condensation of refrigerant R407C in multiport minichannel section

An experimental investigation on condensation of R134a refrigerant in microchannel heat exchanger

Comparison of pool boiling heat transfer for different tunnel-pore surfaces

THE EFFECT OF LIQUID FILM EVAPORATION ON FLOW BOILING HEAT TRANSFER IN A MICRO TUBE

FLOW BOILING OF ETHANOL IN SMALL DIAMETER TUBES

Australian Journal of Basic and Applied Sciences. Numerical Investigation of Flow Boiling in Double-Layer Microchannel Heat Sink

THE EFFECT OF THE CROSS-SECTIONAL GEOMETRY ON SATURATED FLOW BOILING HEAT TRANSFER IN HORIZONTAL MICRO-SCALE CHANNELS

Influence of the Heat Transfer on the Pressure Field in Radial Diffusers Flows

Experimental and Numerical Investigation of Two- Phase Flow through Enlarging Singularity

Performance Investigation on Electrochemical Compressor with Ammonia

Chapter 10: Boiling and Condensation 1. Based on lecture by Yoav Peles, Mech. Aero. Nuc. Eng., RPI.

Chapter 11: Heat Exchangers. Dr Ali Jawarneh Department of Mechanical Engineering Hashemite University

Simulation Of Compressors With The Help Of An Engineering Equation Solver

Axial profiles of heat transfer coefficients in a liquid film evaporator

Pressure Distribution of Refrigerant Flow in an Adiabatic Capillary Tube

Investigations on Performance of an Auto-Cascade Absorption Refrigeration System Operating with Mixed Refrigerants

EXPERIMENTAL STUDY OF R-134A VAPORIZATION IN MINICHANNELS

Study on Flow Characteristics of Oil Viscosity Pump for Refrigerant Compressors

The correct citation for the paper is:

The Effects of Friction Factors on Capillary Tube Length

CHAPTER 5 CONVECTIVE HEAT TRANSFER COEFFICIENT

Heat Transfer During In-Tube Condensation of CFC-113 with Downflow in Vertical, Internally- Enhanced Tubes

ME 331 Homework Assignment #6

Correlation of Evaporative Heat Transfer Coefficients for Refrigerant Mixtures

Experimental Study of Energy Efficiency of a Single Microtube

General Correlation For Heat Transfer During Condensation in Plain Tubes: Further Development and Verification

Experimental Analysis of Wire Sandwiched Micro Heat Pipes

Optimization of Peripheral Finned-Tube Evaporators Using Entropy Generation Minimization

HFO1234ze(E) And HFC134a Flow Boiling Inside a 4mm Horizontal Smooth Tube

JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (JMET)

Piping Systems and Flow Analysis (Chapter 3)

Fundamental issues, mechanisms and models of flow boiling heat transfer in microscale channels

Keywords: boiling in mini tube, heat transfer behavior, correlations, R-134a and R-600a 1. INTRODUCTION

Performance Characterization of Two Selected Refrigerants in a Flat-Plate Micro-Tube Condenser

EVAPORATIVE CO 2 HEAT TRANSFER MEASUREMENTS FOR COOLING SYSTEMS OF PARTICLE PHYSICS DETECTORS

heat transfer process where a liquid undergoes a phase change into a vapor (gas)

Heat Transfer Characteristics for Condensation of R134a in a Vertical Smooth Tube

Heat Transfer Correlations for Small Closed End Heat Pipe with Special Vapor Chamber

Scale-up problems are often perceived as difficult. Here the reaction calorimetry has proven to be

TWO-PHASE FLOW BOILING IN MICROCHANNELS FOR COOLING OF MICROELECTRONICS

USING MULTI-WALL CARBON NANOTUBE (MWCNT) BASED NANOFLUID IN THE HEAT PIPE TO GET BETTER THERMAL PERFORMANCE *

Transcription:

Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 1 Effect of Oil on Flow Boiling Heat Transfer and Flow Patterns of CO in 11. mm Horizontal Smooth and Enhanced Tube Seongho Kim skim11@illinois.edu Predrag S. Hrnjak Follow this and additional works at: http://docs.lib.purdue.edu/iracc Kim, Seongho and Hrnjak, Predrag S., "Effect of Oil on Flow Boiling Heat Transfer and Flow Patterns of CO in 11. mm Horizontal Smooth and Enhanced Tube" (1). International Refrigeration and Air Conditioning Conference. Paper 1331. http://docs.lib.purdue.edu/iracc/1331 This document has been made available through Purdue e-pubs, a service of the Purdue University Libraries. Please contact epubs@purdue.edu for additional information. Complete proceedings may be acquired in print and on CD-ROM directly from the Ray W. Herrick Laboratories at https://engineering.purdue.edu/ Herrick/Events/orderlit.html

519, Page 1 Effect of Oil on Flow Boiling Heat Transfer and Flow Patterns of CO in 11. mm Horizontal Smooth and Enhanced Tube Seongho KIM 1 *, Pega HRNJAK 1, 1 Air Conditioning and Refrigeration Center, Department of Mechanical Science and Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 11, USA (17 3, 17 333 19, skim11@illinois.edu) CTS - Creative Thermal Solutions, Urbana, IL 1, USA * Corresponding Author ABSTRACT Flow boiling heat transfer characteristics of CO with and without oil were investigated experimentally in horizontal smooth and enhanced tubes with an inner diameter of 11. mm. The visualization of flow pattern was also performed to provide the detailed attributes of the nucleate and the convective boiling heat transfer. In order to investigate the effect of the miscible oil on the heat transfer of CO, POE (polyolester) RENSIO C5E oil is added to give an oil circulation rate (OCR) between.5 % and %. Results are compared with those of pure CO. The experimental conditions include evaporation temperatures of -15 C, mass fluxes from to kg/m s, heat fluxes from.5 to 1 kw/m, and vapor qualities from.1 to.. Oil generally deteriorates the heat transfer coefficient of pure CO. The reduction in heat transfer coefficient is most apparent at low vapor qualities,.1 to., and at low mass fluxes, 1 and kg/m. It is caused by the suppression of nucleate boiling due to increased surface tension. At conditions where the convective boiling contribution is dominant, vapor qualities above.5, oil increases heat transfer coefficients. Through visualization, it is shown that the wetted area on the perimeter of inner tube is enhanced due to formation of foaming in the smooth tube. However, such enhancement of heat transfer due to forming is negligible in the enhanced tube, because the enhanced factor due to micro-finned structures is dominant. 1. INTRODUCTION Due to growing concerns of the ozone depletion and global warming, CO has drawn great attention as an alternate environmentally-friendly refrigerant. Refrigeration systems using CO as a working fluid are already commercialized on the market. Recent literature reviews by Thome and Ribatski (5) and Zhao and Bansal (7a) (9a) reveal that many researchers experimentally investigated the flow boiling heat transfer of pure CO. Especially at low evaporation temperatures under -1 C, several experiments had been conducted by Bredesen et al. (1997), Knudsen & Jensen (1997), Hassan (), Park & Hrnjak (5) (7), Zhao & Bansal (7b) (9b), and Kim et al. (1). Comparing to pure CO, however, experimental studies on oil/co mixtures are somewhat limited. In typical refrigeration or air-conditioning systems, a small amount of the lubricating oil migrates from the compressor and through the system, which considerably affect the heat transfer performance of the components. In order to understand the effect of oil on the heat transfer characteristics, it is necessary to measure the flow boiling heat transfer coefficient of both pure CO and oil/co mixtures. At low evaporation temperature of -3 ~ -1 C, it is seen Hassan () that the heat transfer coefficient decreases continuously as oil concentration increases, although positive effects of oil addition have been observed in some other studies of other types of mixtures (Bandarra et al., 9). Furthermore, there is no information about the flow boiling heat transfer of pure CO and oil/co mixtures in the enhanced tube at low evaporation temperature under -15 C. In addition to measurement of heat transfer coefficient, it is essential to observe two-phase flow patterns through visualization in order to

519, Page understand comprehensively two-phase flow boiling heat transfer characteristics. To our best knowledge, however, there has been no study on visualization of oil/co mixtures, even though flow patterns have been observed for other refrigerants and oil mixtures (Bandarra et al., 9). In this paper, we study the flow boiling heat transfer and the corresponding flow patterns of CO with and without oil in the smooth and enhanced tubes with large diameter.. EXPERIMENTAL FACILITY AND TEST CONDITIONS Figure 1 shows a schematic of the experiment facility. The test facility consists of a refrigerant loop for testing, and a secondary coolant loop with HFE 71 for controlling the test conditions. In the test loop, liquid refrigerant is pumped by the gear pump to the calorimeter, which heats it to the quality desired at the inlet of the test section. And visualization section is located after the test section. The control heater adds heat to maintain a desired saturation temperature in the test section. The refrigerant leaves the test section and condenses in a plate heat exchanger connected to the RA cooling unit. The single phase, secondary HFE 71 loop subcools the refrigerant in the subcooler and then adds heat in the test section, as shown in Fig. 1. Polyolester (POE) oil, RENISO C5E (density at 15 C is 1 kg/m 3 and viscosity at C is mm /s), is used as the lubricating oil. It is completely miscible with CO under operating evaporation temperatures and is widely used in industry. The mass of liquid CO in the system is calculated by each test, and enough oil is added to achieve the desired oil circulation rate (OCR). The OCR is held constant during each experiment, and oil separator keeps oil from entering the fade-out vessel. The test section consists of the test tube, brass jacket, and tube circuit for HFE as presented at Fig 1. The inside and outside diameters of the smooth tube are 11. and 15. mm, respectively. The enhanced tube, of which inner melting diameter is 11.17 mm, has micro-fins along the internal periphery with helix angle of 3. The copper tube has a heated length of 15 mm which is surrounded by a two-piece, cylindrical brass jacket. The secondary fluid, HFE, flows around this jacket, in order to provide a uniform temperature. The brass jacket unifies normally low temperature glide of the secondary fluid, HFE, used here for heating. All gaps between the two brass pieces and the test tube are filled with high thermal conductivity paste and they are held tight with metal clamps to reduce the contact thermal resistance. Thermocouples are placed at the top, bottom, and sides at 3 locations along test section. The thermocouples were attached with solder in grooves carved on the tube surface. The remaining portion of the groves is filled with high thermal conductivity paste. The thermocouples are equally spaced along the axis of the test section at 5 mm intervals starting 5 mm from the inlet of the heated section. As a result, the temperatures at 1 points on the tube surface are measured and their average values are used to calculate the heat transfer coefficient. T-type thermocouples with a calibrated accuracy of ±.1 C are used to measure the refrigerant temperature and wall temperature of the test tube. The absolute pressure of CO is determined by a pressure transducer with an uncertainty of ±3. kpa and pressure drops are evaluated by differential pressure transducers with the accuracy of Figure 1: Simplified schematic of the test facility

519, Page 3 ±. kpa. The refrigerant mass flow rate is measured by a mass flow meter with an accuracy of ±.1 % of the reading. Electrical power inputs to the calorimeter and HFE heater are measured with watt transducers which have. % reading accuracy. The visualization section, followed by the test section, consists of a glass tube and fittings covered with a polyester block. The inner and outer diameters of glass tube are 11.7 mm and 1 mm, respectively and the length is mm. The glass tube is enclosed by the thick polyester block, the size of 13 mm, in order to prevent the generation of frost caused by low temperatures and endure operating pressure. Flow boiling heat transfer coefficients for CO with and without oil are measured at a saturation temperature of -15 C, mass flux of, 1, and kg/m, heat flux of.5,1,, 5, and 1 kw/m and qualities between.1 and.. 3. DATA REDUCTION In order to obtain an average heat transfer coefficient, the heat transfer rate to the refrigerant which is CO in this study, Q, is determined as shown in the following equation. ref Q ref = ( mc P ) HFE ( THFE i THFE o ) + Q Amb Q,, Cond (1) Q ref h = Asurf ( TW TCO ) () From Eq. (1) the heat transfer rate from secondary fluid was determined from the HFE specific heat, mass flow rate, and temperature difference between the inlet and outlet of the test section. The heat exchange rate with the environment, Q, was obtained in a calibration experiment where an electrical heater was inserted in the test Amb section while the power was carefully measured and presented as a function of the overall heat transfer coefficient of the test section and the log mean temperature difference between the HFE and the ambient air. The axially transferred conduction heat loss through the pipe, Q, is estimated by a finite element code and experimentally Cond checked. As presented in Eq. (), the average heat transfer coefficient, h, is determined from the calculated heat transfer rate to refrigerant, Q, the measured average tube wall temperature, the test tube geometry, and the ref refrigerant saturation temperature calculated from the measured saturation pressure. Data regression and determination of refrigerant properties are performed using Engineering Equation Solver (5). The uncertainty of the heat transfer coefficient occurs due to the uncertainties of the independent measured parameters: temperature, pressure, mass flow, and electrical power input as presented earlier. The uncertainty propagation of heat transfer coefficient is evaluated based on Moffat (19). The uncertainty is within the range of ~ % of the measured heat transfer coefficients, and is shown as a vertical error bar in the figures..1 Effect of Oil Addition in the Smooth Tube. RESULTS AND DISCUSSION.1.1 Flow Pattern of Pure CO and Oil/CO mixtures: In Fig., we compare the flow patterns of pure CO and oil/co mixture of % OCR obtained through visualization in a smooth tube, vapor quality from.1 to., and mass flux from to kg/m s. For comparison, the Wojtan et al. (5) flow pattern map of pure CO is presented in both Figs. a-b. For pure CO results shown in Fig. a, stratified and stratified-wavy flows are observed throughout all mass fluxes and vapor qualities and neither slug flow nor annular flow does appear unlike predicted by the Wojtan el al. (5) flow pattern map. It results from the relatively small density ratio of vapor to liquid of CO comparing to other refrigerants. Therefore the velocity difference at the vapor-liquid interface is not significant and, thus, the shear force is not enough to generate slug flow or annular flow. Park and Hrnjak (5) also showed that the region of slug + stratified wavy flow shrank as the transition to stratified flow occurred at much lower vapor quality than predicted by Wojtan et al. (5). It will be shown later that such stratified-type flow patterns cause decrease in the heat transfer coefficient as increase of quality, as the dry-out region on the top of the tube grows.

519, Page Figure : The visualization results of two-phase flow patterns of (a) pure CO and (b) oil/co mixture of % OCR in the smooth tube at the vapor quality from.1 to., and the mass fluxes of, 1, and kg/m s, which are compared to the Wojtan et al. (5) two-phase flow patterns map. For the observed flow patterns of oil/co mixture of % OCR, shown in Fig. b, more various types of flow patterns are obtained. Slug flow (low vapor qualities of.1 and.5), annular-wavy, and semi-annular flows (vapor qualities higher than.5) appear at mass fluxes over 1 kg/m s, where the flow pattern had been occupied by stratified and stratified-wavy flow for pure CO. Our visualization results reveal that the formation of foaming, developed throughout all experimental ranges in the oil/co mixture, plays a more critical role to alter its flow pattern with oil addition. To our best knowledge, this is the first observation of foaming in the oil/co mixture, even though it is presented in the previous studies of other refrigerant and oil mixtures, e.g., naphthenic oil/r-1 by Manwell & Bergles (199) and PAG oil/ R-13a by Wongwises et al. (). The visualization results of pure CO and oil/co mixture ( % OCR) are presented in Fig. 3 at high vapor qualities of.7 or. for the mass fluxes of, 1, and kg/m s. At lowest mass flux of kg/m s, the developed foam (a) Pure CO (b) Pure CO % OCR G = [kg/m s] (a) G = [kg/ m s], x =.1 G = 1 [kg/m s] Vapor Velocity =.1 [m/s] Foam Velocity =.5 [m/s] Liquid Velocity =.51 [m/s] G = [kg/m s] (b) Estimation of each velocity Figure 3: Two-phase flow patterns of pure CO and oil/co mixture of % OCR in the smooth tube at vapor quality from of.7/., the mass fluxes of and kg/m s, and the heat flux of 1 kw/m. Figure : Two-phase flow patterns of pure CO and oil/co mixture of % OCR in the smooth tube at vapor quality from of.1, the mass fluxes of kg/m s, and the heat flux of 1 kw/m.

519, Page 5 H ea t tra ns fer coefficient [kw /m K] (a ) q =.5 [kw /m ] 1 G = 1 [kg /m s ] P ure C O 1 % OC R (b) q = 5 [kw /m ] 1 G = 1 [kg /m s ] P ure C O.5 % OC R 1 % OC R (c) q = 1 [kw /m ] 1 G = 1 [kg /m s ] P ure C O.5 % OC R 1 % OC R (d) q = 1 [kw /m ] 1 G = [kg /m s ] P ure R 7.5 % OC R 1 % OC R Figure 5: Heat transfer coefficients of oil/co mixtures in the smooth tube at the heat fluxes of (a).5, (b) 5, and (c) 1 kw/m for the mass flux of 1 kg/m s and at the heat flux of (d) 1 kw/m for the mass flux of (b) kg/m s layer generates waves at the liquid-vapor interface due to the increased shear force, which results in the change of flow pattern from stratified-smooth to stratified-wavy flow. As increasing the mass flux over 1 kg/m s, the froth, the cluster of foaming diminished in size, tends to attach along the sidewall because of its increased surface tension and sweep the wall surface owing to the amplified vapor velocity with increase in the vapor quality. Such a mechanism of froth advances the annular-like flow pattern to appear at lower mass fluxes and qualities in the presence of oil. Besides, the sweeping motion of foaming on the sidewalls is strongly related with the flow boiling heat transfer with oil addition. At low vapor qualities for the mass flux of kg/m s, the slug flow pattern is observed as shown in Fig. a. Slug flow patterns develop when the wave size grows rapidly to touch the upper wall of the tube due to the Kelvin-Helmholtz instability, which occurs in the presence of sufficient velocity difference across the interface between two fluids. When foaming occurs with oil addition, the process of stress dispersion through revolving motions of bubbles causes the reduction of velocity of foam layer in the flowing direction and, accordingly, the velocity difference across vapor-foam interface increases to generate the slug flow. To verify this, the velocities of vapor, foam near the vapor-foam interface, and liquid layer are estimated by tracking a sampled particle in each layer, shown in Fig. b, to be.1,.5, and.51 m/s, respectively..1. Flow Boiling Heat Transfer of Pure CO and Oil/CO mixtures: Fig. 5 represent the flow boiling heat transfer coefficients of pure CO and oil/co mixtures with respect to the varying heat and mass fluxes at the given evaporation temperature respectively and the effects of heat flux, mass flux, and quality are studied. As the oil is added, shown in Fig. 5c-d, the flow boiling heat transfer coefficient decreases as OCR increases from.5 to %. For higher qualities over., however, the decrease in the flow boiling heat transfer coefficient becomes almost negligible or even enhanced. It can be explained by the development of foaming as mentioned in section.1.1. For pure CO, the flow boiling heat transfer coefficient of pure CO decreases as quality increases because the dry-out region on the top of the tube grows in the stratified-types flow as explained by Kim et al. (1) through analyzing local heat transfer coefficients. When the oil is added, however, the development of foaming tends to increase the wetted fraction of the tube wall and, thus, provides positive effect of oil addition within the partial ranges. Figure 5a-c depicts the flow boiling heat transfer coefficients of oil/co mixtures over the heat flux ranged from.5 to 1 kw/m for a given mass flux of 1 kg/m s. The deterioration of the flow boiling heat transfer coefficient of oil/co mixtures increases as the heat flux increases, especially at low vapor qualities. It is because the nucleate boiling suppression is not obvious at low heat flux ranges. Such reduction in heat transfer coefficient is consequential with a small amount of oil addition of.5 % OCR, and then becomes nearly independent on OCR.. Effect of Oil Addition in the Enhanced Tube..1 Flow Pattern of Pure CO and Oil/CO mixtures: The visualized flow patterns of pure CO and the oil/co mixture of % OCR in a micro-fin tube with 3 helix angle are presented in Fig. with superimposed Wojtan et al.

519, Page Figure : The visualization results of two-phase flow patterns of (a) pure CO and (b) oil/co mixture of % OCR in the enhanced tube at the vapor quality from.1 to., and the mass fluxes of,,, 1, and kg/m s. The Wojtan et al. (5) flow pattern map of pure CO in the smooth tube is superimposed as a reference. (5) flow pattern map of pure CO in a smooth tube as a reference. The predominant flow pattern of pure CO in the enhanced tube, shown in Fig. a, is the semi annular flow, resulting from the enhanced momentum of the fluid by the micro-fin structure. Comparing the results oil/co mixtures to those of pure CO, the flow patterns remain mostly unchanged with oil addition unlike the results in the smooth tube. Figure 7 shows the visualized flow patterns of pure CO and oil/co mixture of % OCR at the vapor quality of.7 for the mass fluxes of kg/m s. Even though, foaming is observed in the visualization of oil/co mixture, both pure CO and oil/co mixture display typical annular flow. Dissimilar to the effect of foaming in the smooth tube (i.e., developing semi annular flow from otherwise stratified flow by enhancing the wetted area on the wall), the development of foaming due to oil addition does not affect the flow pattern of annular flow in the enhanced tube. It shows different tendency from the results by Manwell and Bergles (199) that foaming disappears in the enhanced tube. (a) Pure CO (b) % OCR Figure 7: The visualized flow patterns of (a) pure CO and (b) oil/co mixtures of % OCR in the enhanced tube at vapor quality of.7, the mass flux of kg/m s, and the heat flux of 1 kw/m. (a) (a ) G = 1 [kg /m s] 1 (S mooth) ID 11. [mm] (E nhanced) P ure C O H ea t tra ns fer coeffic ient [kw /m K] (b) G = [kg /m s] 1 Figure : Heat transfer coefficients of oil/co mixtures in the enhanced tube at the heat flux of 1 kw/m and the mass fluxes of (a) 1 and (b) kg/m s. (S mooth) ID 11. [mm] (E nhanced) P ure C O

519, Page 7 (a) S mooth tube. 1. 1 G [kg/m s] P ure C O.5 % OC R (b) E nhanced tube. 1. 1 G [kg/m s] P ure C O.5 % OC R P res s ure D rop [kp a /m] 1... 1..... Figure 9: Measured pressure drops of pure CO and oil/co mixtures at the mass fluxes of 1 kg/m s and kg/m s in (a) smooth and (b) enhanced tubes... Flow Boiling Heat Transfer on Pure CO and Oil/CO mixtures: Figure shows the heat transfer coefficients of pure CO and oil/co mixture ( % OCR) in the micro-fin tubes as a function of vapor quality at the mass fluxes of 1 and kg/m s. It can be seen from Fig. a that in the enhanced tube the flow boiling heat transfer coefficients of pure CO increase as the vapor quality increases. For the annular flow developed earlier due to the micro-fin structure effect, as shown through visualization results, the increase of vapor velocity at higher vapor quality enhances the convective heat transfer. When oil is added, the deterioration of flow boiling heat transfer coefficient in the enhanced tube is limited to the vapor qualities above., in contrast with the results in smooth tube showing significant reduction of heat transfer at low qualities. Ha & Bergles (1993) and Zurcher et al. (1997) (1999) also observed the similar trend, local deterioration of the heat transfer of the oil/co mixtures at high vapor qualities over.7. It can be explained by the dominant contribution of the convective boiling owing to the earlydeveloped annular flow, which makes the effect of nucleate boiling inconsequential. At high vapor qualities, however, the oil is accumulated in the partial space between micro fins, causing increase of the thermal resistance, and, thus, the heat transfer is reduced, as suggested by Ha and Bergles (1993)..3 Pressure Drop on Pure CO and Oil/CO mixtures Figure 9 presents the measured pressure drop, measured per 1 m long horizontal smooth tube with an accuracy of ±. kpa, of pure CO and oil/co mixtures from.5 to % OCR in the smooth and micro-fin tubes. The overall magnitudes of pressure drop obtained in the smooth tube are not considerable, less than.5 kpa/m, due to the relatively large diameter of the tube, even though they become more significant in the enhanced tube. The pressure drop increases as the vapor quality and mass flux increase since the higher fluid velocity induces more friction between fluid and wall. The effect of oil on the pressure drop is not critical because the density of the oil is close to the density of CO at the evaporation temperature of -15 C. 5. SUMMARY AND CONCLUSIONS The flow boiling heat transfer coefficients and visualized flow patterns are experimentally investigated in the horizontal smooth and enhanced tube of 11. mm inner diameter for CO and oil/co mixtures at evaporation temperature of -15 C, mass fluxes from to kg /m s, and heat fluxes from.5 to 1 kw/m, and for vapor qualities from.1 to.. The effects of heat flux, mass flux, and quality on the flow boiling of heat transfer and flow pattern are presented and the changes in the heat transfer performance with oil addition are analyzed. The flow boiling heat transfer trend of pure CO agrees with previous studies. The results in the smooth tube show that the strong dependence of nucleate boiling and the effect of mass flux are important to determine the flow pattern and corresponding heat transfer performance. The effect of lubricating oil is also investigated with an OCR of.5 to %. When the nucleate boiling is dominant, oil addition degrades the heat transfer of two phase flow, due to the

519, Page suppression of nucleate boiling. However, the development of foaming resulted from the oil is shown to change flow pattern to annular-like flow and so increase heat transfer coefficient in certain cases, by reducing wall dry-out. On the other hands, in the enhanced tube, the contribution of convective boiling heat transfer is dominant due to the semi annular flow patterns developed earlier: the flow boiling heat transfer coefficient increases as the vapor quality and mass flux increase, and the effect of oil addition is much less significant, comparing to the results in the smooth tube. The pressure drop is not significant in such tubes with relative large diameter, even though it increases with the fluid velocity and micro-fin structure. NOMENCLATURE A area (m ) Subscripts C P specific heat (J/kg K) Amb ambient G mass flux (kg/m s) Cond conduction h heat transfer coefficient (W/m K) HFE secondary fluid, HFE m mass flow rate (kg/s) i inlet P red reduced pressure l liquid q heat flux (W/m ) o outlet Q heat transfer rate (W) ref refrigerant T temperature ( C or K) sat saturation x quality W wall REFERENCES Bandarra, E.P., Cheng, L.X., Thome, J.R., 9, Flow boiling characteristics and flow pattern visualization of refrigerant /lubricant oil mixtures, Int. J. Refrig., vol. 3, no. : p. 15-. Bredesen, A.M., Hafner, A., Pettersen, J., Neksa, P., Aflekt P.K., 1997, Heat transfer and pressure drop for in-tube Evaporation of CO, Proc. of Int. Conference on Heat Transfer Issues in Natural Refrigerants, University of Maryland: p.1-15. Ha, S., Bergles, A.E., 1993, Influence of oil on local evaporation heat transfer inside a horizontal microfin tube, ASHRAE Transaction, vol. 99, no. 1: p. 1-15. Hassan, M.,, Flow boiling of pure and oil Contaminated carbon dioxide as refrigerant, PhD thesis, Department of Mechanical Engineering, Technical University of Denmark. Kim, S., Pehlivanoglu, N., Hrnjak, P.S., 1, R7 Flow boiling heat transfer with and without oil at low temperatures in 11. mm horizontal smooth tube, International Refrigeration and Air Conditioning Conference at Purdue, Purdue University, West Lafayette, IN, USA. Klein, S.A., 5, Engineering equation solver, V7.57, F-Chart Software, Madison, WI, USA. Knudsen, H.J., Jensen, P.H., 1997, Heat transfer coefficient for boiling carbon dioxide, in: Workshop Proceedings of CO Technologies in Refrigeration, Heat Pumps and Air Conditioning Systems, Trondhein: p. 319-3. Manwell, S.P., Bergles, A.E., 199, Gas-liquid flow patterns in refrigerant-oil mixtures, ASHRAE Transactions, vol. 1, no. : p. 5-. Moffat, R.J., 19, Describing the uncertainties in experimental results, Exp Therm Fluid Sci., vol. 1: p. 3-17. Park, C.Y., Hrnjak, P.S., 5, Flow boiling heat transfer of CO at low temperatures in a horizontal smooth tube, J. Heat Transfer, vol. 17: p. 135-131. Park, C.Y., Hrnjak, P.S., 7, Carbon Dioxide and R1A Flow Boiling Heat Transfer, Pressure Drop, and Flow Pattern in Horizontal Tubes at Low Temperatures, ACRC TR-5, Department of Mechanical and Industrial Engineering University of Illinois at Urbana-Champaign. Thome, J.R., Ribatski, G., 5, State-of-the-art of two-phase flow and flow boiling heat transfer and pressure drop of CO in macro- and micro-channels, Int. J. Refrigeration, vol., no. : p. 119-11. Wojtan, L., Ursenbacher, T., Thome, J.R., 5, Investigating of flow boiling in horizontal tubes: part I-A new adiabatic two-phase flow pattern map, Int. J. Heat Mass Transfer, vol. : p. 955-99.

519, Page 9 Wongwises, S., Wongchang, T., Kaewon, J., Wang, C.,, A visual study of two-phase flow patterns of HFC- 13a and lubricant oil mixtures, Heat Transfer Engineering, vol. 3, no. [July/August]: p. 13-. Zhao, X., Bansal, P.K.,, An overview of heat transfer characteristics of carbon dioxide (CO ) Refrigerant. Proc. IIR-IRHACE International Conference on Innovation Equipment and System for Comfort and Food Preservation, Auckland, New Zealand: p. 97-3. Zhao, X., Bansal, P.K., 7a, Critical review of flow boiling heat transfer of CO lubricant mixtures, International Congress of Refrigeration, Beijing. Zhao, X., Bansal, P.K., 7b, Flow boiling heat transfer characteristics of CO at low temperatures, Int. J. Refrig., vol. 3, no. : p. 937-95. Zhao, X., Bansal, P.K., 9a, Critical review of flow boiling heat transfer of CO -lubricant mixtures, Int. J. heat and mass transfer, vol. 5 no. 3-: p. 7-79. Zhao, X., Bansal, P.K., 9b, Experimental investigation on flow boiling heat transfer of CO at low temperatures, J. Heat Transfer Eng., vol. 3, no. 1-. Zurcher, O., Thome, J.R., Favrat, D., 1997, Flow boiling and pressure drop measurements for R13a/oil mixtures part 1: evaporation in a plain tube, HVAC&R Res., vol. 3, no. 1: p. 5-. Zurcher, O., Thome, J.R., Favrat, D., 1999, In-tube flow boiling of R7C and R7C/oil mixtures part 1: microfin tube, HVAC&R Res., vol., no. : p. 37-37. ACKNOWLEDGEMENT This study is supported by Air-Conditioning and Refrigeration Center (Project 3) at University of Illinois at Urbana-Champaign. The authors are grateful to Wolverine Tube Co. (M. Neshan) for their support in building the facility and 3M Company for support in HFE, the secondary refrigerant supply.