FRAGMENT SCREENING IN LEAD DISCOVERY BY WEAK AFFINITY CHROMATOGRAPHY (WAC )

Similar documents
Introduction to FBDD Fragment screening methods and library design

Unlocking the potential of your drug discovery programme

Implementation of novel tools to facilitate fragment-based drug discovery by NMR:

Monolith NT.Automated Product Information

György M. Keserű H2020 FRAGNET Network Hungarian Academy of Sciences

Fragment-based drug discovery

NMR Solutions for drug discovery

Fragment Screening in Drug Discovery

Fragment-Based Drug Discovery (FBDD) Using the dispr Technique on Pioneer Systems with OneStep and NeXtStep Injection Methodologies

Building innovative drug discovery alliances

Z -LYTE Assay Setup Guide on the BMG LABTECH CLARIOstar Reader

Small-Molecule Kinetics

Small-Molecule Kinetics

Isothermal Titration Calorimetry in Drug Discovery. Geoff Holdgate Structure & Biophysics, Discovery Sciences, AstraZeneca October 2017

Department of Biochemistry, University of Zürich, Winterthurerstrasse 190, CH-8057 Zürich, Switzerland

La RMN quantitative appliquée aux petites molécules

Hit Finding and Optimization Using BLAZE & FORGE

The Nanostream (Pasadena, CA) Veloce system,

Kinetic & Affinity Analysis

Application Note. Authors. Introduction. Lauren E. Frick and William A. LaMarr Agilent Technologies, Inc. Wakefield, MA, USA

Nanoliter Scale High-Throughput Protein Crystallography Screening with the Echo Liquid Handler

Computational chemical biology to address non-traditional drug targets. John Karanicolas

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns

+ butanal + 2-picolineborane. + acetic acid. + butanal + 2-picolineborane. + acetic acid

Dr. Sander B. Nabuurs. Computational Drug Discovery group Center for Molecular and Biomolecular Informatics Radboud University Medical Centre

CHIRAL SEPARATION USING THIN LAYER CHROMATOGRAPHY

Quality control analytical methods- Switch from HPLC to UPLC

Supporting Information

Quantification of free ligand conformational preferences by NMR and their relationship to the bioactive conformation

Roadblocks in HTS Assay Development

Virtual Screening: How Are We Doing?

Supporting Information for: Using a Lipase as a High Throughput Screening Method for Measuring the Enantiomeric. Excess of Allylic Acetates

Peptide Isolation Using the Prep 150 LC System

COMBINATORIAL CHEMISTRY IN A HISTORICAL PERSPECTIVE

Six Biophysical Screening Methods Miss a Large Proportion of Crystallographically Discovered Fragment Hits: A Case Study

Characterization of Reversible Kinase Inhibitors using Microfluidic Mobility-Shift Assays

Supporting Information. for

Tag lite: assessment of compound dissociation from GPCRs. Israel Ramos Villullas Group leader of GPCRs and Ion Channels unit BRADS Department

LanthaScreen Eu Kinase Binding Assay Validation Packet. Optimization of a LanthaScreen Eu Kinase Binding Assay for AURKB

Confirmation of In Vitro Nefazodone Metabolites using the Superior Fragmentation of the QTRAP 5500 LC/MS/MS System

(Supplementary Information)

LanthaScreen Eu Kinase Binding Assay Validation Packet. Optimization of a LanthaScreen Eu Kinase Binding Assay for RPS6KA1

Supporting Information. Labeled Ligand Displacement: Extending NMR-based Screening of Protein Targets

Electronic Supplementary Information for. A Redox-Nucleophilic Dual-Reactable Probe for Highly Selective

Biophysics Service at the MPIB Biochemistry Core Facility Stephan Uebel, Biochemistry Core Facility

17. Biomolecular Interaction

LanthaScreen Eu Kinase Binding Assay Validation Packet

ImprovIng ADmE ScrEEnIng productivity In Drug DIScovEry

Presentation Microcalorimetry for Life Science Research

NMR study of complexes between low molecular mass inhibitors and the West Nile virus NS2B-NS3 protease

LC Technical Information

This is a repository copy of Biophysics in drug discovery : impact, challenges and opportunities.

Accelerating the Metabolite Identification Process Using High Resolution Q-TOF Data and Mass-MetaSite Software

Problem Set 5 Question 1

FRAUNHOFER IME SCREENINGPORT

BRIEFING. (EXC: K. Moore.) RTS C Propylparaben C 10 H 12 O Benzoic acid, 4 hydroxy, propyl ester; Propyl p hydroxybenzoate [ ].

Ultra-HTS Using 3456-Well Plate and HTRF Technology in GPCR Drug Discovery

Improved 6- Plex TMT Quantification Throughput Using a Linear Ion Trap HCD MS 3 Scan Jane M. Liu, 1,2 * Michael J. Sweredoski, 2 Sonja Hess 2 *

Important Aspects of Fragment Screening Collection Design

Using AutoDock for Virtual Screening

CHAPTER 1 Role of Bioanalytical Methods in Drug Discovery and Development

Rapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS

SUPPLEMENTARY INFORMATION

Mnova Software Tools for Fragment-Based Drug Discovery

Applications of Fragment Based Approaches

TEMPLATE FOR AN EXAMPLE STANDARD TEST METHOD

Chapter 6. The interaction of Src SH2 with the focal adhesion kinase catalytic domain studied by NMR

Protein structure based approaches to inhibit Plasmodium DHODH for malaria

High Performance Liquid Chromatography. Table 1: Allowed HPLC Adjustment of USP <621> and EP <2.2.46>

Quantitation of a target protein in crude samples using targeted peptide quantification by Mass Spectrometry

Dispensing Processes Profoundly Impact Biological, Computational and Statistical Analyses

Shodex TM ODP2 HP series columns

Photo-responsive MOFs: Light-induced switching of porous single crystals containing photochromic diarylethene

HIGH-THROUGHPUT DETERMINATION OF AQUEOUS SOLUBILITY, PRECIPITATION OR COLLOIDAL AGGREGATE FORMATION IN SMALL MOLECULE SCREENING SETS

Supporting Information

Electronic Supplementary Information for: agent. Adam J. Plaunt, Kasey J. Clear, and Bradley D. Smith*

Advanced Medicinal Chemistry SLIDES B

HPLC AND 13 C NMR FOR ANALYSIS OF TRANSAMIDATION IN A DYNAMIC COMBINATORIAL CHEMISTRY SYSTEM

(Supplementary Information)

In silico pharmacology for drug discovery

Use of Ultra-High Performance LC-MS for Challenging Assays. David Browne, Laboratory Manager (LC-MS-MS), Covance Laboratories, Harrogate

A High Sensitivity Dual Solid Phase Extraction LC-MS/MS Assay for the Determination of the Therapeutic Peptide Desmopressin in Human Plasma

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Supporting Information

Structure-based maximal affinity model predicts small-molecule druggability

COMBINATORIAL CHEMISTRY: CURRENT APPROACH

ZAHID IQBAL WARRAICH

Molecular Imaging of Labile Iron(II) Pools in Living Cells with a Turn-on Fluorescent Probe

Multi-residue analysis of pesticides by GC-HRMS

Supplementary Table 1. Small molecule screening data

Intelligent NMR productivity tools

3) In CE separation is based on what two properties of the solutes? (3 pts)

Rational design of a hexapeptide hydrogelator for controlled-release drug delivery

Application Note. Edgar Naegele. Abstract

Highly automated protein formulation development: a case study

Revision Bulletin 27 Jan Feb 2017 Non-Botanical Dietary Supplements Compliance

Receptor Based Drug Design (1)

EMPIRICAL VS. RATIONAL METHODS OF DISCOVERING NEW DRUGS

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

Supporting Information

Transcription:

FRAGMENT SCREENING IN LEAD DISCOVERY BY WEAK AFFINITY CHROMATOGRAPHY (WAC ) SARomics Biostructures AB & Red Glead Discovery AB Medicon Village, Lund, Sweden

Fragment-based lead discovery The basic idea: Screen few fragments (100 1,000) - Less complex molecules higher probability to bind - Less resource intensive than HTS - Better sampling of chemical space Find weak but efficient i (high h binding energy per atom) binders Develop into more potent compounds using structural information HTS hit Fragment hits Boyd, Turnbull & Walse (2012) Fragment library design considerations, WIREs Comput. Mol. Sci., 2, 868-885.

Conventional HTS vs. fragment screening in drug discovery Figure adapted from Duong-Thi, 2013, Thesis.

Structure-based and fragment-based discovery of vemurafenib Vemurafenib (PLX4032) The usage of FBLD combined with SBDD was a critical success factor in the development of vemurafenib

Fragment-based lead discovery Fragment screening Medicinal chemistry Synthesis (small molecules & peptides) Analytical chemistry (NMR & MS/MS) In vitro biology In vitro ADME/physchem HTS/FBLG expertise Screening technologies In silico screening Thermoshift assay (DSF) NMR WAC Biochemical screening (HCS) X-ray crystallography MST Compounds Proprietary library Specifically ordered sets Client libraries Structure-based drug design X-ray crystallography Computational chemistry NMR spectroscopy Biophysics Protein chemistry

Primary screening techniques NMR screening Thermal shift assay / DSF Weak Affinity Chromatography Sample changer screens 96 samples overnight Cryoprobe equipped 800 MHz NMR instrument Ligand-observed 1 H NMR spectra NMR analysis/titration of selected hits Initial screening 0.1 mg g/ /ml 0.2 mg/ml ΔTm at 62.5 μm ΔTm at 62.5 μm RG200001 5.95 7.3 RG200001 6.3 6.4 RG200002 9.6 10.4 RG200002 10.2 10.7 RG200003-1.3-0.48 RG200003-0.9-0.76 Dose response curves Target protein immobilized on HPLC column MS-detection Physiological buffer as mobile phase Retention time of fragments related to selective interactions ti with targett Simultaneous identification of weak binders (mm) in complex mixtures

Secondary and follow-up techniques X-ray crystallography MST, microscale thermophoresis HCS high concentration biochemical screening High-throughput low volume crystallization Soaking pools of fragments Co-crystallization ti of selected fragments High-throughput data collection (autom. synchrotron beamlines) Structure determination and refinement through automated data pipelines pp EC50=44 µm Versatile plate readers FRET, TRF, AlphaLisa, fluorescence polarization etc Crystallization robotics MAX IV Measures the motion of molecules along microscopic i temperature t gradients K d, dissociation constant: nm to mm range Rapid assay optimization Fast measurement: K d in 10 min Low sample consumption: minimal concentration (nm) and small volume (<4 µl) 96-1536 well plate Development and optimization Buffer composition, Additions, Linearity, Kinetic parameters Screening Robustness (Z -factor), reagent stability, reproducibility (day-to-day variation), DMSO sensitivity, automation

Weak affinity chromatography (WAC ) Principles i of WAC Data analysis Affinity constant (KD) is calculated from the retention time difference ( t ret ) for the compounds on target and blank columns. Column with immobilized protein Fragment binding WAC attractive as primary fragment screening assay Column without protein (blank column) Column cross section Invented by Prof. Sten Ohlson (Linnaeus University, it Sweden) Commercial rights by Transientic Interactions AB (TI) SARomics and RGD in unique collaboration with TI offering exclusive service platform Fragment mix Affinity LC-MS column Schematic representation of screening using WAC 0.5 minutes retention time difference is significant Extracted ion chromatograms K D = B tot /( t ret flowrate)

Some technical details WAC Typical setup: Target protein coupled via lysine residues Mixes of 10-40 cmpds (1 µm, n=2) ~1-4 mg protein on LC column (e.g. 2.1 x 50 mm) Each LC run of 30-60 minutes Affinity range: 100 µm 4 mm (can be adjusted)

WAC data on bromodomain (BRD4) Application within Nile project

BRIEF SUMMARY WAC-screening of 155 fragments Fragment lib. MW: 123-308, average MW = 239 10-fragment-mixtures 20 mm sodium acetate buffer Robustness Unchanged performance of BRD4-column over time (>1 months at least) Re-test with every two 10-mixes pooled into one 20-mix provided very similar results RG210073 (IC50 = 40 µm in biochemical assay) included in all mixes as control; ( µ y) ; Retention time = 138 ± 5 minutes (%CV = 3.9%) on BRD4-column (n=18)

Actives Retention time difference was used to identify actives: Δt ret = t BRD4-col t control_column A fragment with Δt ret > 2 minutes considered to active (provided that also (Δt ret /t BRD4-col ) > 0.1) Data suggest that t WAC has a lower degree of false positives than other techniques such as DSF and high h concentration biochemical screening No screened 155 No hits (Δt ret > 2 min) 23 No strong hits (Δt ret > 5 min) 13 Hit rate 15% WAC only technique revealing RG200067 reported by Pfizer as BRD4 binding fragment Ref: Fish et al., J Med Chem (2012), 55(22), 9831 H N RG200067 O Br N

Comparison with other techniques BRD4 screening hits HSP90 screening hits Using a WAC -cutoff of t ret > 5 min, all fragments verified by other Screening of 111 fragments by WAC, techniques except: NMR, SPR, FP and Tm shift. Selected RG200054 and RG200067 (reference cmpd Pfizer-hit ) fragments also by ITC and X-ray RG210010 and RG200039 not tested in other assays crystallography. Fragments listed with decreasing affinities as measured by WAC. (Meiby et al. 2013, Anal. Chem., Compound ID Δt ret (min) WAC Biochem DSF NMR X-ray 85, 6756) RG210073 138.1 A (IC50 ~50 µm) A NT YES RG210080 87.2 A (56%@100µM) A NT YES RG210070 84.1 Tendency of activity A NT YES RG210074 71.4 A (54%@100µM) A NT YES RG210069 52.1 Tendency of activity A NT YES RG210081 35.1 A (45% inhib@100µm) A NT YES RG210079 28.3 A (31% inhib@100µm) A NT YES RG200067 18.8 NA NA NA 4HBV RG210019 10.7 NA A NA NT RG100104 7.6 NT NA A NT RG200054 7.3 NA NA NT NT RG100056 6.8 NT NT A NT RG210010 5.9 Not tested in any other assay RG200039 5.0 Not tested in any other assay A = active; NA = not active; NT = not tested

Hit rate BRD PPI 70% 60% 50% 40% 30% 20% 10% 0% 61% 12% < 0.25 min 0.25 to 0.5 min 9% 6% 7% 5% 0.5 to 1 min 1 to 2 min 2-5 min > 5min 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0% 86% 8% < 0.25 min 0.25 to 0.5 min 3% 2% 1% 0% 0.5 to 1 min 1 to 2 min 2-5 min > 5min Screens performed in duplicate

WAC for complex mixtures Reaction mixtures Extracts from natural sources, i.e. natural products Analysis of Protein Target Interactions of Synthetic y g y Mixtures by Affinity-LC/MS. Singh et al. SLAS Discov. 2017 Apr;22(4):440-446

Beneficial WAC characteristics Throughput mixes, detection of multiple binders Robustness low variation between replicates, long column life time Cost efficiency low consumption of protein and fragments, standard equipment Quality automatic quality control, not sensitive for impurities Ranking immediate ranking