Comparison of Polymer Separation by Size Exclusion Chromatography and Asymmetric Flow Field Flow Fractionation

Similar documents
Dr. Christoph Johann Wyatt Technology Europe GmbH Copyright Wyatt Technology Europe GmbH All Rights reserved 1

Polymer analysis by GPC-SEC. Technical Note. Introduction

Branching Revealed: Characterizing Molecular Structure in Synthetic and Natural Polymers by Multi-Angle Light Scattering

Field-Flow Fractionation of Macromolecules and Structures That Cannot be Characterized by Conventional GPC/SEC Techniques

Tips & Tricks GPC/SEC: From a Chromatogram to the Molar Mass Distribution

Latest Developments in GPC Analysis of Adhesive and Sealant Polymers Mark Pothecary PhD Americas Product Manager Malvern Instruments

Quick guide to selecting columns and standards for Gel Permeation Chromatography and Size Exclusion Chromatography SELECTION GUIDE

Practical Steps in GPC Method Development

Gel Permeation Chromatography

GPC/SEC Practical Tips and Tricks. Thomas Dent Applications Scientist Agilent Technologies. October, 2011 Gulf Coast Conference

Molecular weight of polymers. Molecular weight of polymers. Molecular weight of polymers. Molecular weight of polymers. H i

Polymers Reactions and Polymers Production (3 rd cycle)

GPC - Gel Permeation Chromatography. aka Size Exclusion Chromatography- SEC

Maximizing Performance Through GPC Column Selection

An Introductions to Advanced GPC Solutions

Gel Permeation Chromatography

How to use GPC/SEC for compositional analysis

GPC/SEC standards. Product guide

Advanced GPC. GPC On Tour, Barcelona, 28 th February The use of Advanced Detectors in GPC

Gel Permeation Chromatography (GPC) or Size Exclusion Chromatography (SEC)

GPC/SEC standards. Product guide

Comprehensive Polymer Analysis Strategies

c) fitting of the NMR intensity in dependence of the recycle delays 4

Characterization of polyphenylene sulphide using the Agilent PL-GPC 220 High Temperature GPC System with triple detection

GPC/SEC Column Selection & Method Development

GPC / SEC Theory and Understanding

Clearing the Confusion: GPC, SEC, GFC What, When, Why, and How?

Optimizing GPC Separations

Application compendium. Authors. Greg Saunders, Ben MacCreath Agilent Technologies, Inc. A guide to multi-detector gel permeation chromatography

No.106. Aqueous SEC Columns for Analysis of Cationic Polymers: TSKgel PWXL-CP Series. Contents. Page

GPC/SEC An essential tool for polymer analysis

FFF-MALS method development and measurements of size and molecular weight

Liquid storage: Holds the solvent which is going to act as the mobile phase. Pump: Pushes the solvent through to the column at high pressure.

COURSE MATERIAL: Unit 3 (Part 1) Polymer Science LT8501 (Click the link Detail to download)

Sem /2007. Fisika Polimer Ariadne L. Juwono

Gel Permeation Chromatography Basics and Beyond eseminar March 13, Jean Lane Technical and Applications Support LSCA, Columns and Supplies

Lecture 4 : Gel Permeation or Size Exclusion Chromatography

Macromolecular Chemistry

Ring-Opening Polymerization of N-Carboxyanhydrides Initiated by a Hydroxyl Group

Setting the Standard for GPC. Complete Guide for GPC / SEC / GFC Instrumentation and Detection Technologies. The Right Instrument for Your Application

[VIM = 4 R3 gx ( 3)

Calibration and Normalization of MALS Detectors

Optimization of PLA/PLGA molecular weight and structure to suit final application requirements

Progress toward reliable NC molecular mass distribution by GPC

Size Exclusion Chromatography of Poly(2-ethyl-2-oxazoline) Homopolymers and Poly(ethylene oxide)-b-poly(2-ethyl-2-oxazoline) Copolymers

Determination of Polymer Modifier in Asphalt

Analysis of polyolefins by GPC/SEC

Benefit of light scattering technologies (RALS/LALS/MALS) and multidetection characterization in life science research?

Molecular Weight of Polymers *

MEASURING PROTEIN AGGREGATION WITH THE VISCOTEK SEC-MALS 20

CALIBRATING GPC COLUMNS

Abstract: An minimalist overview of chromatography for the person who would conduct chromatographic experiments, but not design experiments.

MALVERN ADVANCED GPC/SEC DETECTORS SETTING THE STANDARD MOLECULAR WEIGHT MOLECULAR SIZE MOLECULAR STRUCTURE

EcoSEC - semi-micro GPC/SEC system for high throughput polymer analysis

Analysis of Fragile Ultra-High Molar Mass. d Chromatography. Amandaa K. Brewer October 22, 2015

The ph-responsive behaviour of aqueous solutions of poly(acrylic acid) is dependent on molar mass

Use of SEC-MALS. (Size Exclusion Chromatography - Multi Angle. Light Scattering) for protein quality and characterization

Tips & Tricks GPC/SEC: Quantify and Get More Than Molar Mass Averages

(3) A UNIVERSAL CALIBRATION FOR GEL PERMEATION CHROMATOGRAPHY. [TIM = 4 R3 gx POLYMER LETTERS VOL. 5, PP (1967)

Tips & Tricks GPC/SEC: Inter-Detector Delay

Analysis of Star Polymers Using the Agilent 1260 Infinity Multi-Detector GPC/SEC System

How switching mobile phases can improve your OMNISEC results

Supporting Information

OVERVIEW INTRODUCTION. Michael O Leary, Jennifer Gough, Tanya Tollifson Waters Corporation, Milford, MA USA

CHARACTERIZATION OF BRANCHED POLYMERS IN SOLUTION (I)

The power of multi-detector SEC in the analysis of antibodies

High Performance Liquid Chromatography

Differentiation of polymer branching and composition using the Mark Houwink plot

Use of High Speed/High Resolution Size-Based Chromatographic Separation of Polymeric Mixtures with Offline Infrared Detection

Light Scattering, Size Exclusion Chromatography and Asymmetric Flow Field Flow Fractionation

Waters GPC User Guide and Tutorial for Using the GPC in the Reynolds Research Group 2 nd Edition: April 2012

Scheme 1: Reaction scheme for the synthesis of p(an-co-mma) copolymer

GPC/SEC Start-up Kit

OVERVIEW INTRODUCTION

The ultimate in desktop particle characterization

Organic GPC/SEC columns. Product guide

Tips & Tricks GPC/SEC: Protein Analysis with Size-Exclusion Chromatography

Chapter 14. Molar Mass Distribution.

Mathematic Expression of Enthalpy Partition in Coupled Polymer Liquid Chromatography

Molecular Weights of Copolymers Obtained by Gel Permeation Chromatography Light Scattering

GPC/MS. Analysis of PET

CHEM 429 / 529 Chemical Separation Techniques

The ultimate in desktop particle characterization

TSKgel Size Exclusion Chromatography Columns

Macromolecular colloids. Size and shape of linear macromolecules. Osmosis and osmotic pressure.

Solvent Flexibility for Size-Based Polymer Analysis Using the Advanced Polymer Chromatography (APC) System

Field-Flow-Fractionation

Size Exclusion Chromatography

(Received 9 September 2005, Accepted 15 November 2005)

GPC/SEC Troubleshooting Volume 1

Supporting Information

Size Exclusion Chromatography: Method Development

Development of a Size Exclusion Chromatography method for analysis of extraction solutions from urinary catheters

HPLC Background Chem 250 F 2008 Page 1 of 24

Covalent incorporation of the surfactant into high internal phase emulsion templated polymeric foams

Molecular Weight Distribution of Living Chains in Polystyrene Pre-pared by Atom Transfer Radical Polymerization

TECHNICAL NOTEBOOK No.1. GPC LF series columns. Linear calibration curves over a wide molecular weight range. TECHNICAL NOTEBOOK. No.

Evaluation of round robin test results for a size exclusion chromatography method for the analysis of nitrocellulose

Investigating the Relationship Between the Rheological Properties of Hyaluronic Acid and its Molecular Weight and Structure using Multidetector

Polymer Separations by Chemical Composition Using SEC-Gradients

Transcription:

Comparison of Polymer Separation by Size Exclusion Chromatography and Asymmetric Flow Field Flow Fractionation Stepan Podzimek, 1 Christoph Johann 2 1 SYNPO / University of Pardubice, Czech Republic, stepan.podzimek@synpo.cz 2 Wyatt Technology Europe, Dernbach, Germany

Overview Size exclusion chromatography (SEC/GPC) versus asymmetric flow field flow fractionation (A4F/AF4) Multi-angle light scattering (MALS) detection for both SEC and AF4 (No calibration by polymer standards) Data to compare SEC and AF4 separation of narrow polymers Molar mass averages by SEC-MALS and AF4-MALS Mass recovery in AF4 Molar mass distribution by SEC-MALS and AF4-MALS Conformation plots (branching) by SEC-MALS and AF4-MALS Examples of application Conclusions

AF4-MALS and SEC-MALS Instrumentation The presented data were acquired using instrumentation from Wyatt Technology Corporation AF4 system Eclipse AF4 MALS detector HELEOS Refractive index detector Optilab T-rEX Software ASTRA 6 Waters and Agilent Agilent 1100 pump Waters 717 autosampler Agilent 2 PLgel Mixed-C or Mixed-B columns 300 7.5 mm

What Is AF4? o o o o o Alternative separation technique to SEC/GPC Separation according to hydrodynamic volume No stationary phase only solvent Separation by flow in a thin ribbon like channel created by sandwiching a thin spacer between two blocks One block is solid, one is semipermeable frit covered by semipermeable membrane

AF4-MALS and SEC-MALS Experiments Polymers of different molar mass, linear and branched, narrow and broad; polystyrene, poly(methyl methacrylate), polycarbonate, acrylic emulsion copolymers, Mass recovery and molar mass averages o Stock solutions dispensed into well-sealed autosampler vials, each vial used just for a single injection, 100 µl 0.2 0.5 % solutions in THF, identical injected mass in SEC and AF4 o Mass recovery in AF4 was compared relatively to SEC to avoid systematic errors given by RI calibration or dn/dc o The same injected mass in SEC-MALS and AF4-MALS o Four or five injections for each sample, presented data are averages THF as solvent for SEC and AF4 Cross flow gradient in AF4, 5 kda regenerate cellulose membrane

Processing AF4-MALS and SEC-MALS Data MALS of non-fractionated polydisperse polymers provides weight-average molar mass (M w ) and z-average root mean square (RMS) radius (R z ). The M w and R z count more the fractions with high molar mass, R z counts more than M w. Assumption: Slice polydispersity in SEC and AF4 is negligible, i.e., MALS detector measures molar masses M i and RMS radii R i and not averages o o o This assumption is never completely fulfilled due to limited resolution of SEC columns or AF4 channel Typically the polydispersity can be neglected without introducing significant errors (good agreement of M n measured by SEC-MALS and MO; and M z measured by SEC-MALS and calculated from R z ) Simplification od data processing

Narrow Polymers (Polystyrene Standards)

Relative Scale Narrow Polystyrene Standards 1.0 SEC 0.8 0.6 0.4 0.2 2875 K 900 K 400 K 200 K 90 K 19 K Relative Scale 0.0 1.0 0.8 0.6 0.4 0.2 AF4 8 10 12 14 16 2875 K 900 K 19 K 90 K 200 K 400 K 0.0 15 20 25 30 35 40 MALS signals for a mixture of PS standards separated by SEC and AF4. AF4 is less efficient (peak width) and more selective (retention time difference).

Average Molar Masses Mass Recovery

Average Molar Masses and Mass Recovery

Average Molar Masses and Mass Recovery Number-Average molar mass o AF4 yields slightly higher M n for linear polymers due to better resolution of SEC in lower molar mass region and/or permeation of oligomeric fractions through semipermeable membrane o Difference of M n is larger for samples containing more oligomers o AF4 yields lower M n for branched polymers due to more efficient separation of branched macromolecules Weight-average molar mass o AF4 yields slightly higher M w as the concentration in A4F channel is typically lower compared to SEC column and thus lower error from neglecting the A 2 o AF4 yields markedly higher M w for polymers containing ultra-high molar mass fractions due to the absence of stationary phase and significantly lower pressure in AF4 channel, which reduces shearing degradation Z-average molar mass o Typically well-comparable M z o AF4 yields markedly higher M z for polymers containing ultra-high molar mass fractions due to reduced shearing degradation Mass recovery o No systematic deviation of AF4 from SEC o Mass recovery depends on the content of oligomeric fractions o Mass recovery in AF4 for samples not containing oligomers is close to 100 %

Molar Mass and Size Distribution

Linear Polymers: Molar Mass 10 6 SEC 10 6 AF4 10 5 10 5 10 4 10 12 14 16 10 4 15 20 25 30 35 40 Molar mass versus retention time plots of linear polystyrene determined by SEC-MALS and AF4-MALS. RI signals are overlaid here.

Linear Polymers: RMS Radius 80 SEC 80 AF4 RMS Radius (nm) 10 RMS Radius (nm) 10 9 10 11 12 13 14 15 20 25 30 35 40 Root mean square (RMS) radius versus retention time plots of linear polystyrene determined by SEC-MALS and AF4-MALS. RI signals are overlaid here.

Linear Polymers: Molar Mass Distribution Cumulative Weight Fraction 1.0 0.8 0.6 0.4 0.2 SEC-MALS AF4-MALS M n = 116,000 / 141,000 g/mol M w = 280,000 g/mol / 295,000 g/mol M z = 468,000 g/mol / 472,000 g/mol 0.0 10 4 10 5 10 6 Cumulative molar mass distribution of linear polystyrene determined by SEC-MALS and AF4-MALS.

Linear Polymers: Conformation Plot SEC vs. AF4 RMS Radius (nm) 10 5 10 6 Root mean square (RMS) radius (radius of gyration) versus molar mass plots of linear polystyrene determined by SEC-MALS and AF4-MALS.

Branched Polymers: Molar Mass 10 7 SEC 10 7 AF4 10 6 10 5 10 6 10 5 8 10 12 14 16 18 Volume (ml) 10 4 20 30 40 50 Molar mass versus retention time plots of branched polystyrene determined by SEC-MALS and AF4-MALS. RI signals are overlaid here.

Branched Polymers: RMS Radius 100 SEC 100 AF4 RMS Radius (nm) RMS Radius (nm) 10 8 10 12 14 16 18 10 20 30 40 50 Root mean square (RMS) radius versus retention time plots of branched polystyrene determined by SEC-MALS and AF4-MALS. RI signals are overlaid here.

Branched Polymers: Molar Mass Distribution 1.0 10 7 SEC Cumulative Weight Fraction 0.8 0.6 0.4 0.2 10 6 10 5 8 10 12 14 16 18 Volume (ml) SEC-MALS AF4-MALS M n = 149,000 / 124,000 g/mol M w = 475,000 g/mol / 631,000 g/mol M z = 2.1 x 10 6 g/mol / 6.8 x 10 6 g/mol 0.0 10 4 10 5 10 6 10 7 Cumulative molar mass distribution of branched polystyrene determined by SEC-MALS and AF4-MALS.

Branched Polymers: Conformation Plot 100 SEC vs. AF4 RMS Radius (nm) 10 10 5 10 6 10 7 10 7 10 6 10 5 SEC RMS Radius (nm) 8 10 12 14 16 18 Volume (ml) 100 SEC 10 8 10 12 14 16 18 Root mean square (RMS) radius versus molar mass plots of branched polystyrene determined by SEC-MALS and AF4-MALS. Basic assumption is not valid!

Delayed SEC Elution of Branched Polymers SEC 100 RMS Radius (nm) 10 8 10 12 14 16 18 Large branched molecules are anchored in pores and elute later than it would correspond to their hydrodynamic size Slices at high elution volumes are contaminated by delayed large molecules and MALS detector measures M w and R z The fundamental assumption od SEC-MALS and AF4-MALS is not fulfilled The delayed elution increases polydispersity of slices at the end of SEC chromatogram, which makes the conformation plots upturned

Polymers Interacting with Column Packing

Polymers Interacting with Column Packing 10 6 10 8 10 5 10 7 10 6 10 5 10 4 12 14 16 18 10 4 20 30 40 50 Molar mass versus retention time plots of functional polymer determined by SEC-MALS and AF4-MALS overlaid on RI signals.

Polymers Containing Insoluble Nanogels

Polymers Containing Insoluble Nanogels 1.0 0.8 Swollen gel nanoparticles Relative Scale 0.6 0.4 0.2 Dissolved macromolecules 0.0 15 20 25 30 35 40 45 50 THF solutions of methyl methacrylate/butyl acrylate copolymers containing (from left to right) 0, 1, 2, 4, 6, and 8 % ethylene glycol dimethacrylate; and RI fractograms of copolymers containing 2 % (blue), 4 % (red) and 8 % (green) ethylene glycol dimethacrylate.

Polymers with Ultra-High Molar Mass Species 10 8 10 7 10 6 10 5 10 4 20 30 40 50 Molar mass versus retention time plot (ο) and signals of MALS (red) and RI (blue) detectors of methyl methacrylate/butyl acrylate copolymer.

Polymers with Ultra-High Molar Mass Species 100 RMS Radius (nm) 10 10 5 10 6 10 7 Conformation plot of methyl methacrylate/butyl acrylate copolymer showing two different slopes of 0.48 and 0.31.

Organic Nanoparticles in Epoxy Resin 1.8x10 8 80 1.6x10 8 1.4x10 8 1.2x10 8 70 60 RMS Radius (nm) 1.0x10 8 14 16 18 20 22 24 RI fractogram and molar mass vs. retention time and RMS radius vs. retention time plots for organic nanoparticles added to epoxy resin. For linear random coils RMS radius 65 nm corresponds to molar mass 1.9 x 10 6 g/mol compact structure of nanoparticles. 50

Conclusions AF4 compared to SEC Absence of stationary phase reduces shearing degradation, and eliminates anchoring effect and interactions of polymer with stationary phase 1. Polymers containing ultra-high molar mass fractions 2. Polymers containing highly branched species 3. Polymers containing nano-gels and nanoparticles Functional polymers interacting with SEC column packing The same HPLC pump, autosampler and detectors for SEC and AF4