Analysis of thermal effects in grouped silos of grain elevators

Similar documents
The University of Melbourne Engineering Mechanics

Behavioral Study of Cylindrical Tanks by Beam on Elastic Foundation

N = Shear stress / Shear strain

QUESTION BANK DEPARTMENT: CIVIL SEMESTER: III SUBJECT CODE: CE2201 SUBJECT NAME: MECHANICS OF SOLIDS UNIT 1- STRESS AND STRAIN PART A

Name :. Roll No. :... Invigilator s Signature :.. CS/B.TECH (CE-NEW)/SEM-3/CE-301/ SOLID MECHANICS

Strength of Material. Shear Strain. Dr. Attaullah Shah

Horizontal bulk material pressure in silo subjected to impulsive load

QUESTION BANK SEMESTER: III SUBJECT NAME: MECHANICS OF SOLIDS

Sabah Shawkat Cabinet of Structural Engineering Walls carrying vertical loads should be designed as columns. Basically walls are designed in

Visit Abqconsultants.com. This program Designs and Optimises RCC Chimney and Foundation. Written and programmed

Storage silo for sugar

STRESS, STRAIN AND DEFORMATION OF SOLIDS

Pullout Tests of Geogrids Embedded in Non-cohesive Soil

Chapter 12. Static Equilibrium and Elasticity

D : SOLID MECHANICS. Q. 1 Q. 9 carry one mark each.

CIVIL DEPARTMENT MECHANICS OF STRUCTURES- ASSIGNMENT NO 1. Brach: CE YEAR:

Structural Analysis I Chapter 4 - Torsion TORSION

Chapter 5 Torsion STRUCTURAL MECHANICS: CE203. Notes are based on Mechanics of Materials: by R. C. Hibbeler, 7th Edition, Pearson

Investigation of thermal effects on analyses of truss structures via metaheuristic approaches

MODELING THE EFFECTIVE ELASTIC MODULUS OF RC BEAMS EXPOSED TO FIRE

D : SOLID MECHANICS. Q. 1 Q. 9 carry one mark each. Q.1 Find the force (in kn) in the member BH of the truss shown.

STANDARD SAMPLE. Reduced section " Diameter. Diameter. 2" Gauge length. Radius

Entrance exam Master Course

Discrete Element Modelling of a Reinforced Concrete Structure

Strain Measurement. Prof. Yu Qiao. Department of Structural Engineering, UCSD. Strain Measurement

NUMERICAL SIMULATIONS OF CORNERS IN RC FRAMES USING STRUT-AND-TIE METHOD AND CDP MODEL

SRI CHANDRASEKHARENDRA SARASWATHI VISWA MAHAVIDHYALAYA

An Analytical Solution for Hoop Tension in Liquid Storage Cylindrical Tanks

Parametric analysis and torsion design charts for axially restrained RC beams

CALCULATION OF A SHEET PILE WALL RELIABILITY INDEX IN ULTIMATE AND SERVICEABILITY LIMIT STATES

Practice Final Examination. Please initial the statement below to show that you have read it

9 Stresses. 9.1 Stress states in silos

2012 MECHANICS OF SOLIDS

UNIVERSITY OF SASKATCHEWAN ME MECHANICS OF MATERIALS I FINAL EXAM DECEMBER 13, 2008 Professor A. Dolovich

PERIYAR CENTENARY POLYTECHNIC COLLEGE PERIYAR NAGAR - VALLAM THANJAVUR. DEPARTMENT OF MECHANICAL ENGINEERING QUESTION BANK

3-D FINITE ELEMENT MODELLING OF GRANULAR FLOW IN SILOS

DEPARTMENT OF MECHANICAL ENIGINEERING, UNIVERSITY OF ENGINEERING & TECHNOLOGY LAHORE (KSK CAMPUS).

The Islamic University of Gaza Department of Civil Engineering ENGC Design of Spherical Shells (Domes)

Rigid pavement design

CHAPTER 4: BENDING OF BEAMS

RODS: THERMAL STRESS AND STRESS CONCENTRATION

Optimization of blank dimensions to reduce springback in the flexforming process

Back Calculation of Rock Mass Modulus using Finite Element Code (COMSOL)

The theories to estimate lateral earth pressure due to a strip surcharge loading will

A Study of Annular Plate Buckling Problem with Tension Loaded at Inner Edge

Effect of uniform and gradient thermal loadings on cylindrical steel reservoirs (analytical investigation)

CHAPTER 5 Statically Determinate Plane Trusses

University of Sheffield The development of finite elements for 3D structural analysis in fire

3 Hours/100 Marks Seat No.

CHAPTER 5 Statically Determinate Plane Trusses TYPES OF ROOF TRUSS

COURSE TITLE : APPLIED MECHANICS & STRENGTH OF MATERIALS COURSE CODE : 4017 COURSE CATEGORY : A PERIODS/WEEK : 6 PERIODS/ SEMESTER : 108 CREDITS : 5

BE Semester- I ( ) Question Bank (MECHANICS OF SOLIDS)

1. A pure shear deformation is shown. The volume is unchanged. What is the strain tensor.

Author(s) Sawamura, Yasuo; Kishida, Kiyoshi;

ME Final Exam. PROBLEM NO. 4 Part A (2 points max.) M (x) y. z (neutral axis) beam cross-sec+on. 20 kip ft. 0.2 ft. 10 ft. 0.1 ft.

3.2 Reinforced Concrete Slabs Slabs are divided into suspended slabs. Suspended slabs may be divided into two groups:

IDE 110 Mechanics of Materials Spring 2006 Final Examination FOR GRADING ONLY

ME411 Engineering Measurement & Instrumentation. Winter 2017 Lecture 9

SEMM Mechanics PhD Preliminary Exam Spring Consider a two-dimensional rigid motion, whose displacement field is given by

Centrifuge Shaking Table Tests and FEM Analyses of RC Pile Foundation and Underground Structure

Uncertainty modelling using software FReET

Flexural properties of polymers

Strength of Materials Prof S. K. Bhattacharya Department of Civil Engineering Indian Institute of Technology, Kharagpur Lecture - 18 Torsion - I

Influence of residual stresses in the structural behavior of. tubular columns and arches. Nuno Rocha Cima Gomes

ALACPA-ICAO Seminar on PMS. Lima Peru, November 2003

Model tests and FE-modelling of dynamic soil-structure interaction

EQUIVALENT FRACTURE ENERGY CONCEPT FOR DYNAMIC RESPONSE ANALYSIS OF PROTOTYPE RC GIRDERS

Mechanical properties 1 Elastic behaviour of materials

Free Body Diagram: Solution: The maximum load which can be safely supported by EACH of the support members is: ANS: A =0.217 in 2

PROBLEM #1.1 (4 + 4 points, no partial credit)

Stress Analysis Lecture 3 ME 276 Spring Dr./ Ahmed Mohamed Nagib Elmekawy

Influence of bond-slip on the behaviour of reinforced concrete beam to column joints

NORMAL STRESS. The simplest form of stress is normal stress/direct stress, which is the stress perpendicular to the surface on which it acts.

: APPLIED MECHANICS & STRENGTH OF MATERIALS COURSE CODE : 4021 COURSE CATEGORY : A PERIODS/ WEEK : 5 PERIODS/ SEMESTER : 75 CREDIT : 5 TIME SCHEDULE

AE3610 Experiments in Fluid and Solid Mechanics TRANSIENT MEASUREMENTS OF HOOP STRESSES FOR A THIN-WALL PRESSURE VESSEL

R13. II B. Tech I Semester Regular Examinations, Jan MECHANICS OF SOLIDS (Com. to ME, AME, AE, MTE) PART-A

SELECTED PROBLEMS OF SHORT CIRCUIT WITHSTANDABILITY Section II - POWER TRANSFORMER October 2004, Vigo - Spain

FINITE ELEMENT ANALYSIS OF THE ROTATION CAPACITY OF BEAM-TO-COLUMN END-PLATE BOLTED JOINT

MECHANICS OF MATERIALS Sample Problem 4.2

Mechanistic Pavement Design

EXPERIMENTS ON SHEAR-FLEXURAL BEHAVIORS OF MODEL CAST IN PLACE CONCRETE PILES

6.4 A cylindrical specimen of a titanium alloy having an elastic modulus of 107 GPa ( psi) and

TESTS ON REINFORCED CONCRETE LOW-RISE SHEAR WALLS UNDER STATIC CYCLIC LOADING

Experimental Research on Ground Deformation of Double Close-spaced Tunnel Construction

EMA 3702 Mechanics & Materials Science (Mechanics of Materials) Chapter 2 Stress & Strain - Axial Loading

ε t increases from the compressioncontrolled Figure 9.15: Adjusted interaction diagram

PDDC 1 st Semester Civil Engineering Department Assignments of Mechanics of Solids [ ] Introduction, Fundamentals of Statics

QUANTITATIVE DAMAGE ESTIMATION OF CONCRETE CORE BASED ON AE RATE PROCESS ANALYSIS

A RESEARCH ON NONLINEAR STABILITY AND FAILURE OF THIN- WALLED COMPOSITE COLUMNS WITH OPEN CROSS-SECTION

Composite bridge design (EN1994-2) Bridge modelling and structural analysis

Downloaded from Downloaded from / 1

Advanced Structural Analysis EGF Cylinders Under Pressure

Design of reinforced concrete sections according to EN and EN

Purpose of this Guide: To thoroughly prepare students for the exact types of problems that will be on Exam 3.

THE INFLUENCE OF THERMAL ACTIONS AND COMPLEX SUPPORT CONDITIONS ON THE MECHANICAL STATE OF SANDWICH STRUCTURE

Numerical Modelling of Dynamic Earth Force Transmission to Underground Structures

Evaluation of Flexural Stiffness for RC Beams During Fire Events

FE analysis of steel-concrete composite structure with partial interactions

Mechanics of Solids. Mechanics Of Solids. Suraj kr. Ray Department of Civil Engineering

CE : CIVIL ENGINEERING

Transcription:

Int. Agrophysics, 2006, 20, 301-307 INTERNATIONAL Agrophysics www.ipan.lublin.pl/int-agrophysics Analysis of thermal effects in grouped silos of grain elevators A. apko and J.A. Prusiel* Institute of Civil Engineering, Bia³ystok University of Technology, Wiejska 45, 15-351 Bia³ystok, Poland Received July 11, 2006; accepted September 27, 2006 A b s t r a c t.the paper presents experimentally registered temperatures occurring in RC grouped silo bins for grain, corresponding to winter operation period in Polish climate conditions. A new generation wireless computerized measurement system was applied, based on the use of telemetric transceivers operating in intelligent radio network. On the basis of experimental temperature distribution, numerical analysis of the hoop thermal stresses and bending moments in reinforced concrete silo battery subjected to grain pressure and thermal gradient was carried out. In the analysis the numerical model of silo wall with interaction between wall structure and stored particulate solid was applied which had previously been developed and validated on a stand-alone ferroconcrete silo bin model. Keywords:temperature fields, thermal stresses, silo battery, structural analysis, finite element method INTRODUCTION Thermal loads on silo wall should be obligatory considered in design of silo structures, and the influence of temperature fields should be carefully studied with respect to the model of thermal effects and idealized model of silo wall structure. The effects on structures of grouped silos in grain Elevators and the requirements for their structural analysis are not specified in recent codes of design (EN 1991-4:2006; PN-B-03262:2002; AS-3774-1996). Previously the problem of thermal effects in RC cylindrical free standing silos was analysed in Canada (Muir et al., 1989), South Africa (Blight, 1990) and last time in Poland ( apko, 2005; apko and Prusiel, 2001; 2003). The paper presents some results of experimental and computational analysis of temperature fields and thermal effects occurring in RC grouped grain silos (arranged as 2 x 2 cylindrical bins) subjected to thermal loads, elaborated using own numerical model taking into account the interaction between wall structure and particulate solids en masse ( apko et al., 2001; apko and Prusiel, 2001). *Corresponding author s e-mail: prusiel@pb.bialystok.pl MONITORING OF THERMAL LOADS AND THERMAL STRESSES IN GROUPED SILOS FOR GRAIN The temperature distributions in a real silo wall in a grain Elevator were monitored using a new generation wireless system equipped with telemetric radio modules (a scheme of such a system is presented in Fig. 1) providing the possibility of testing the silo structure by measurement of mechanical stresses, deformations, displacements or temperatures depending on sensors used. Bi-directional wireless monitoring was carried out by radio transceivers operating with strain gauge measurement circuits ( apko and Ko³³¹taj, 2003). All the measurements are performed over the radio, therefore the telemetry modules are equipped with a number of functions (zeroing, scaling, calibration, filtration) using the wireless technique. The system is equipped with a special algorithm of data transmission. The computer program is implemented into microprocessor system in the transmission modules. The system was specially designed for operation with low level of signals in strain gauge circuits and provided with the following functions: running measurements with displayed values for all sensors (without registration), on-line measurement (with computer registration) and displayed values for chosen channels, off-line registration (without main station), detection of strain gauge damage (shorting of the strain gauges), setting of sampling frequency. Using the above mentioned wireless technique the monitoring of reinforced concrete grouped silo, consisting of a battery of 2 x 2 cylindrical silos in the grain Elevator in Bialystok (Poland), was conducted during a long winter period. The tested silo bins, K 9 and K 11, as seen in the 2006 Institute of Agrophysics, Polish Academy of Sciences

302 A. APKO and J.A. PRUSIEL a b K-9 Fig. 1. Cylindrical silo bin structure during monitoring: a) scheme of wireless transmission: 1 transceivers, 2 main station connected with computer; b) view of tested silo bin K 9 in Bia³ystok Elevator. cross section in Fig. 2, were fully filled with particulate solid (wheat) being in the storing phase. The main geometric data of the silo bins from the grouped silo were as follows: internal diameter dc =8m, total height H =26m, wall thickness t = 0.2 m, length of contact zone between bins L = 2.4 m. Digital temperature sensors type DS18B20 were located at the outer surface of concrete wall along the perimeter, at the level of 8 m above the ground of the silo battery. The temperature test points were distributed in horizontal distance of the bin perimeter with central angle 45 as shown in Fig. 2. The electric resistance strain gauges were localised at the silo height on uncovered outer steel reinforcement bars (with diameter of 12 mm) and located on mean average distance of 150 mm. Fig. 2. Location of temperature test points on the surface of grain silo battery perimeter. The strain test points were localised on the silo bin K 9 at selected four levels situated on two vertical lines A and C (on the levels of 12, 10, 8 and 6 m above the ground see Fig. 2) along vertical cracks observed on the concrete surface. Example diagrams of one week temperature registration (at test points B 8, C 8, D 8 and E 8 as shown in legend) are presented in Fig. 3a. Changes of thermal hoop strains in outer steel bars (at a few selected test points), corresponding to the registered temperature changes, are given in Fig. 3b. It can be clearly seen that the diagrams of temperature and thermal stresses are coupled eg for each phase of temperature drop we observe increase of tensile thermal stresses in the reinforcement and vice versa. SIMULATION OF TEMPERATURE CHANGES IN THE SYSTEM: SILO WALL STRUCTURE STORED BULK SOLID During the investigations temperature changes on external surface of wall perimeter were monitored. For evaluation of corresponding temperature changes on the wall thickness the numerical program based on the Finite Difference Method (FEM) computational procedure was used. The program is based on the principles of heat transfer and moisture migration in cylindrical systems ( apko and Prusiel, 2001; 2003), as shown in Fig. 4. The designed system was subdivided into basic cylindrical layers (RC wall structure and grain) and the following input data were introduced: thickness and number of basic layers, initial temperature and moisture of layer, thermal conductivity characteristics, specific heat, density of material, characteristics of vapour permeability, isotherm of sorption of considered material.

ANALYSIS OF THERMAL EFFECTS IN GROUPED SILOS OF GRAIN ELEVATORS 303 a Strains of steel ( ) Temperature (C) Time (h) b Time (h) Fig. 3. Temperature distributions on silo battery perimeter (December 2002) (a) and corresponding thermal strain changes in reinforcing steel at selected test points (b) ( apko, 2005). Fig. 4. Assumptions for the numerical computation of temperature in the system: silo wall bulk solid ( apko and Prusiel, 2001); T = f(r) temperature function against silo wall radius.

304 A. APKO and J.A. PRUSIEL Temperature changes predicted numerically along the silo bin radius during 19 h long phase of dropping winter temperature (see Fig. 3) are shown in Fig. 5. External temperature changes, Te, needed in the simulation were taken from experimental works and on this basis the internal surface wall temperature changes, Ti, were predicted (Fig. 6). From here the thermal effects components for considered silo battery (linear thermal gradient, T g, and uniform temperature changes, T m ) were established for some selected points on silo wall circumference. The respective results are given in Table 1. FEM ANALYSIS OF THERMAL FORCES IN SILO WALL The structure of a grouped silo is very complex and therefore the known solutions for evaluation of thermal stresses in a freestanding cylindrical silo cannot be used even for symmetrical loads. The FEM was used in structural analysis of considered silo battery subjected to grain pressure and previously predicted thermal effects. In the analysis the discrete numerical model of grouped silo, taking into account interaction between wall structure and stored particulate solid, was applied. This model was previously developed Temperature (C) 16.0 12.0 8.0 4.0 0.0-4.0-8.0-12.0-16.0 WALL WHEAT 0 19 h 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 Design points at the bin radius (cm) Fig. 5. Temperature distribution along the radius of silo bin. -2,0 [deg] Angle () 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160-4,0 Temperature (C) Temperature [ 0 C] -6,0-8,0-10,0-12,0 To Te Tm Tg -14,0-16,0 D8 C8 B8 A8 Test points Fig. 6. Wall temperature distribution over the wall perimeter taken in computer simulations; To, Te external surface temperature at the start and the end of monitoring, respectively, Tm mean wall temperature; Tg temperature difference at the wall thickness.

ANALYSIS OF THERMAL EFFECTS IN GROUPED SILOS OF GRAIN ELEVATORS 305 Table 1.Thermal loads on silo battery wall from monitoring and numerical analysis T Thermal effects (C) H-G F E D C B A T e -6.1-13.6-11.5-10.7-8.1-7.6-7.5 T i -1.6-1.6-1.5-1.6-1.3-0.6-1.0 T g -4.5-12.0-10.0-9.1-6.8-7.0-6.5 T m -3.85-7.6-6.5-6.15-4.7-4.1-4.25 *H, G, F, E, D, C, B, A temperature test points (see Fig. 2). and validated on a silo model ( apko and Prusiel, 2001; 2003). Numerical scheme of analysed horizontal crosssection of silo battery structure is presented in Fig. 7. The contact between adjacent silo bins in grouped silo was modelled assuming real increase of wall stiffness in this zone. European Standard final draft (EN 1991-4: 2006) proposes the following empirical formula for evaluation of unloading effective modulus of particulate solid: E su p, (2) where: p vft vertical stress due to bulk solid pressure at the base of the vertical walled section, modulus contiguity coefficient. In the absence of experimental data from tests, the modulus contiguity coefficient,, may be estimated as: vft 7 3, (3) Fig. 7. Scheme for FEM analysis of silo battery using discrete model of interaction between wall structure and bulk solid. The numerical FEM model of the 2x2bins silo battery is based on the shell plate Finite Elements having radial oriented constrains in the nodes modelling the bulk solid stiffness in the nodes. The elastic stiffness characteristic, C, of stored grain in silo bin was defined considering the equilibrium of deformations of elastic ring in contact with elastic bulk solid core separated from cylindrical silo wall with the diameter, dc, and the wall thickness, t. From the equilibrium of strains we obtain: Es C, (1) 05. ( d t)( 1 ) c where: Es and s are modulus of given bulk solid and its Poisson ratio, respectively. The effective modulus of given particulate solid can be determined experimentally or predicted by indirect assessment depending on unit weight,, of stored solid. s where: unit weight of the stored solid in kn m -3 ; for wheat we have = 7.8 kn m -3. The value of coefficient,, may alternatively be taken as 70 for dry agricultural grains, 100 for small mineral particles, and 150 for large hard mineral particles. The vertical stress in Eq. (2) may be computed from formula based on Janssen pressure: pho pvft K Y j ( z ), (4) where: p Kz, ho o A z o 1 K U, z Y ( z z ) 1 e o, j where: coefficient of friction between silo wall and bulk solid, K characteristic value of the lateral pressure ratio, z depth below the equivalent surface of the solid, A plan cross-sectional area of the silo, U internal perimeter of the plan cross-section of the silo. Assuming the standard approach for the needs of numerical analysis we obtained in the paper: 3 7 78. 152, p vft 62.12 kn m -2, E su 94. MPa.

306 A. APKO and J.A. PRUSIEL The numerical FEM scheme of considered grouped silo was modelled with 4096 finite wall elements having dimensions of 800 x 800 mm and the same number of constrains modelling the core of grain. The silo battery consisted of four cylindrical bins made of concrete class B20. Thermal effects were assumed to be linear across the wall thickness and not uniform on silo battery perimeter (Fig. 2), as given in Table 1. Example diagrams of thermal stresses and bending moments in considered silo bin K 9 structure (for outer arch of the wall), assuming the experimentally registered daily thermal effects, are presented in Fig. 8a (thermal uniform stresses on the wall thickness) and in Fig. 8b (thermal bending moments). The diagrams marked with (C=0) denote the results of numerical tests neglecting interaction between the wall structure and bulk solid stored (for the stiffness characteristic parameter C=0). a Thermal stress (kn m -2 ) b Thermal hoop moments (knm m -1 ) Angle () Angle () Fig. 8. Selected diagrams for outer arch of silo bin K 9 at the level of 5.5 m: a) uniform thermal hoop stresses in concrete, b) thermal hoop moments. The comparison of numerical tests obtained from numerical FEM analysis using the model with interaction (C0) and classic FEM model without interaction (for C=0) shows significant influence of the bulk solid stiffness on the hoop thermal stresses in the silo wall sections. Assuming the reinforced concrete section of silo wall for the computed uniform hoop thermal stress, T, and thermal bending moment, MT, the following formula for evaluation of thermal stresses, st, in outer hoop reinforcement can be used: MT Es st T, (5) W E where: W is the silo wall section modulus and Es/Ecm is the ratio of steel and concrete moduli. Taking the values of M T and st from diagrams (Fig. 8) and assuming for cracked wall concrete modulus E cm = 13.5 GPa, for steel modulus Es = 210 GPa and wall thickness t=0.2 m in the wall cross-section (for the angle = 150)we obtain the value of thermal stresses in hoop tension reinforcement: cm st 82. MPa. (6) To compare this value with the thermal stress changes registered during silo wall monitoring (see Fig. 3b for test point C-8 at the considered level of 8 m of silo wall height) for the measured change of steel strains, s, related to daily temperature drop we obtain: E 0047. 21099. MPa. (7) s s s The discrepancies of thermal stresses in hoop reinforcement of silo battery due to daily drop of ambient temperature predicted experimentally and taken from FEM analysis are not significant and validate the proposed numerical approach for silo battery structural analysis. CONCLUSIONS 1. Experimental analysis of temperature distribution and thermal effects on real silo batteries can be very efficiently carried out using new generation wireless monitoring system. 2. Structural analysis of silo battery structure under bulk solid pressure and non-uniform thermal actions proved that the thermal forces and moments in silo wall sections should be evaluated taking into account the numerical FEM silo bin model assuming the interaction between wall structure and bulk solid. 3. It can be clearly seen from numerical analysis that short time (daily) winter temperature drop influences hoop stresses resulting from bulk solid pressure in the wall section of silo battery and this effect must be considered in design of silo battery structure.

ANALYSIS OF THERMAL EFFECTS IN GROUPED SILOS OF GRAIN ELEVATORS 307 REFERENCES AS-3774-1996. Australian Standard. Loads on bulk solid containers. Published by Standards Australia. Blight G.E., 1990. Temperature surcharge pressures in rein forced concretre silos. Powder Handling and Processing, 2, 4, 303-305. EN 1991-4: 2006. Eurocode 1 Actions on structures Part 4: Silos and tanks. apko A., 2005. Thermal fields in grain during storage their sources and effects on silo structures reliability. Int. Agrophysics, 19, 141-146. apko A. and Ko³³¹taj J., 2003. The wireless technique of examination of silo wall structures during operation. Proc. 4th Int. Conf. Conveying and Handling of Particulate Solids. Budapest, Hungary, 27-30 May, 1, 6.77-6.82. apko A., Nikitin V., Prusiel J.A., and Kowalczyk R., 2001. Prediction of temperature fields and thermal forces in cylindrical shell of silo chamber. Proc. 4th Int. Cong. Thermal Stresses, Osaka, Japan, 537-540. apko A. and Prusiel J.A., 2001. Studies on thermal actions and forces in the cylindrical storage silo bins. Handbook of Conveing and Handling of Particulate Solids. Elsevier, Amsterdam. apko A. and Prusiel J.A., 2003. Experimental and theoretical analysis of thermal effects in full scale grain silo battery. Proc. 5th Int. Cong. Thermal Stresses and Related Topics Blacksburg, Virginia, USA, 8-11 June, 1, MM- 2-1-1-MM-2-1-4. Muir W.E., Jayas D.S., Britton M.G., Sinha R.N., and White N.D.G., 1989. Interdyscyplinary grain storage research. Powder Handling and Processing, 3, 281-295. PN-B-03262: 2002. Reinforced concrete silos for granular substances. Statistic calculations and drafts (in Polish). Polish Standard Committee, Warsaw.