IN order to characterize the

Similar documents
This section reviews the basic theory of accuracy enhancement for one-port networks.

Advancements in mm-wave On-Wafer Measurements: A Commercial Multi-Line TRL Calibration Author: Leonard Hayden Presenter: Gavin Fisher

Accuracy Estimations of S-Parameter Measurements at the Wafer-Level

Ripple Method for Evaluating Residual Errors

TC 412 Microwave Communications. Lecture 6 Transmission lines problems and microstrip lines

On-Wafer Characterization of Electromagnetic Properties of Thin-Film RF Materials

S-Parameter Calibration of Two-Port Setup: Gavin Fisher Cascade Microtech

Lecture 13. Vector Network Analyzers and Signal Flow Graphs

An On-Wafer Deembedding Procedure for Devices under Measurement with Error-Networks Containing Arbitrary Line Lengths

PAD MODELING BY USING ARTIFICIAL NEURAL NETWORK

Calibrating On-Wafer Probes to the Probe Tips

Probe Tip Characterization Using Self-Calibration. Lab. RF Modeling

Calibration Uncertainty Estimation. at the Wafer Level

ECE 497 JS Lecture -07 Planar Transmission Lines

A Multi-Line De-Embedding Technique for mm-wave CMOS Circuits

Broad-band space conservative on wafer network analyzer calibrations with more complex SOLT definitions

UNIT I ELECTROSTATIC FIELDS

ECE 451 Advanced Microwave Measurements. TL Characterization

ECE 497 JS Lecture -03 Transmission Lines

Passive components in MMIC technology

Contents. Transmission Lines The Smith Chart Vector Network Analyser (VNA) ü structure ü calibration ü operation. Measurements

Application of EM- Simulators for Extraction of Line Parameters

Applications of Ferroelectrics for Communication Antennas

Microwave Network Analysis

ECE 451 Transmission Lines & Packaging

ECE 391 supplemental notes - #11. Adding a Lumped Series Element

De-embedding in High Speed Design

Progress In Electromagnetics Research M, Vol. 20, 73 80, 2011

Transmission Lines. Plane wave propagating in air Y unguided wave propagation. Transmission lines / waveguides Y. guided wave propagation

Contents. Transmission Lines The Smith Chart Vector Network Analyser (VNA) ü structure ü calibration ü operation. Measurements

INTRODUCTION TO TRANSMISSION LINES DR. FARID FARAHMAND FALL 2012

Open-Thru de-embedding for Graphene RF devices

Impedance Matching and Tuning

Lipparini* anazysis which compare favourabzy with experimentaz results. The same modez. described. It is shown that the discrepancies between computed

Smith Chart Figure 1 Figure 1.

Boundary and Excitation Training February 2003

Non-Sinusoidal Waves on (Mostly Lossless)Transmission Lines

Technique for the electric and magnetic parameter measurement of powdered materials

Svetlana Carsof Sejas García

CAD modeling of coplanar waveguide (CPW) air-bridges

ELECTROMAGNETISM SUMMARY. Maxwell s equations Transmission lines Transmission line transformers Skin depth

COPLANAR STRIPLINE (CPS) COMPONENTS. Previous Page. lower-frequency regions, without affecting the radiation pattern. 3. TRIANGULAR (BOWTIE) ANTENNAS

ARTIFICIAL TRANSMISSION LINE WITH LEFT/RIGHT-HANDED BEHAVIOR BASED ON WIRE BONDED INTERDIGITAL CAPACITORS

ECE 107: Electromagnetism

2GHz Microstrip Low Pass Filter Design with Open-Circuited Stub

Microwave Circuit Design I

ECE 497 JS Lecture - 18 Impact of Scaling

Determining Characteristic Impedance and Velocity of Propagation by Measuring the Distributed Capacitance and Inductance of a Line

How to measure complex impedance at high frequencies where phase measurement is unreliable.

ABSTRACT. MORGENSEN, MICHAEL P. High-Frequency FET Modeling in GaN with Dispersion Effects. (Under the direction of Professor D. W. Barlage).

Transmission-Reflection Method to Estimate Permittivity of Polymer

PARAMETRIC ANALYSIS ON THE DESIGN OF RF MEMS SERIES SWITCHES

Investigation of Loss Mechanisms in Thin Film Barium Strontium Titanate Capacitors

Advances in Radio Science

Analysis of Characteristics of Coplanar Waveguide with Finite Ground-planes by the Method of Lines

WE PRESENT an iterative algorithm, which we first

STUB BASED EQUIVALENT CIRCUIT MODELS FOR EVEN/ODD MODE DUAL CRLH UNIT CELLS. Faculty of Engineering, Ain Shams University, Cairo, Egypt

Coplanar Microwave Integrated Circuits

6.976 High Speed Communication Circuits and Systems Lecture 2 Transmission Lines

Compact Equivalent Circuit Models for the Skin Effect

PHY3128 / PHYM203 (Electronics / Instrumentation) Transmission Lines

Microwave Engineering 3e Author - D. Pozar

MICROWAVE AND MILLIMETERWAVE ELECTRICAL PERMITTIVITY OF GRAPHENE MONOLAYER. G. Konstantinidis 3

Case Study: Parallel Coupled- Line Combline Filter

Microstrip Coupler with Complementary Split-Ring Resonator (CSRR)

Introduction. A microwave circuit is an interconnection of components whose size is comparable with the wavelength at the operation frequency

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

ECE 598 JS Lecture 06 Multiconductors

ECE 604, Lecture 13. October 16, 2018

Unknown Thru Calibration Algorithm

International Distinguished Lecturer Program

and Ee = E ; 0 they are separated by a dielectric material having u = io-s S/m, µ, = µ, 0

Kimmo Silvonen, Transmission lines, ver

Accounting for High Frequency Transmission Line Loss Effects in HFSS. Andrew Byers Tektronix

Transmission Lines. Transmission lines. Telegraphist Equations. Reflection Coefficient. Transformation of voltage, current and impedance

6-1 Chapter 6 Transmission Lines

Lecture 14 Date:

Characterising Properties and Loss in High Powered Metamaterials

Supporting Online Material for

Module 2 : Transmission Lines. Lecture 1 : Transmission Lines in Practice. Objectives. In this course you will learn the following

Waves on Lines. Contents. ! Transmission Lines! The Smith Chart! Vector Network Analyser (VNA) ! Measurements

Omar M. Ramahi University of Waterloo Waterloo, Ontario, Canada

Contents. ! Transmission Lines! The Smith Chart! Vector Network Analyser (VNA) ! Measurements. ! structure! calibration! operation

Power Splitter Characterisation EM Day

Microwave Phase Shift Using Ferrite Filled Waveguide Below Cutoff

EE301 RESISTANCE AND OHM S LAW

FINAL EXAM IN FYS-3007

ECE357H1F ELECTROMAGNETIC FIELDS FINAL EXAM. 28 April Examiner: Prof. Sean V. Hum. Duration: hours

Experiment 06 - Extraction of Transmission Line Parameters

IMPEDANCE MATCHING CAPABILITY OF NOVEL SOCKET CONTACTOR DESIGN USING VARIABLE OPEN STUBFOR RF PACKAGING TESTING

Problem 1 Γ= = 0.1λ = max VSWR = 13

A CALIBRATION PROCEDURE FOR TWO-PORT VNA WITH THREE MEASUREMENT CHANNELS BASED ON T-MATRIX

Coplanar Waveguides Loaded with Symmetric and Asymmetric MultiSection Stepped Impedance Resonators (SIRs): Modeling and Potential.

Chapter 2 Lateral Series Switches

ECE 546 Lecture 13 Scattering Parameters

Introduction to RF Design. RF Electronics Spring, 2016 Robert R. Krchnavek Rowan University

Understanding EMC Basics

Retract. Press down D RG MG LG S. Recess. I-V Converter VNA. Gate ADC. DC Bias. 20 mk. Amplifier. Attenuators. 0.

Characteristics of Passive IC Devices

INVESTIGATION OF METAMATERIAL UNIT CELLS BASED ON DISPERSION CHARACTERISTICS

Transcription:

D E S G N F E A T U R E VERFY WAFER-PROBE REFERENCE PLANES FOR MMC TESTNG Three techniques for verification of planar calibration standards agree within ko.1 ps of electrical length. N order to characterize the accuracy of on-wafer MMC measurements, it is important to understand microwave wafer-probe calibrations over a matrix of planartransmission-line types, sizes, and substrate materials. One of the calibration issues that arises is the electrical lengths of the planar calibration standards relative to each other and relative to the device under test. Here, three techniques for verification of planar calibration standards are presented and are shown to agree within ko.1 ps of electrical length. This. study is limited to the coplanar waveguide (CPW) geometry of alumina and sapphire impedance standard substrates (SSs) currently available for wafer-probe calibration. The effects of one-port impedance standards on one-port vector network analyzer (VNA) calibrations have been widely reported, along KETH JONES, Senior Microwave Engineer, and ERC STRD, President, Cascade Microtech, nc.. P.O. Box 1589, Beaverton, OR 970751589; (503) 626-8245 k l.ooj- - 4.80 0.80 Deviation from linear phase - 3*20-0.60 J - 1.60 $ 0.40-0.00 f 0.20V - -1.60 g a.20 0.00 - - -4.80-3.20 f h Deviation from linear magnitude 2-0.40 - -6.40, 4.60 k hlaanitudel-., -8*D0-0.80-9.60 1 0 5 10 15 208 25 2.lhedltterenoeinektdcallengthbetweena wallshoftandacoptanarshottcanbe cak&tedwiththoakjofaloox4cakm&i. _-Conductor wall -i-w mg Coplanar short has extra length AT - with examples of typical errors in short-open-load calibrations. Placement of probe tips on a short calibration standard and, to a lesser extent, placement of the tips on a load standard will affect the resulting calibration. For a ground-signal-ground probe-tip configuration, the effect of variations in shorts manifests itself as a variation in electrical length. Varying the placement of the load results in a slight shift in series load inductance. To verify the reactances of the short, open, and load, this study utilized an open or shorted stub as a fourth standard. Typical deviation from linear phase and magnitude of

D E S G N F E A T U R E Wall short 200 400 600 800 1000 1200 Offset length ()-pm 3. These offset short standards were used to relate the coplanar short delay to the actual shorting bar. The delays of five different offset short standards are plotted against their mechanical lengths. Step 1: Perform two.porf calibration in 35mm coax w> S, m Step 2: Measure adapter lengths -> >> 3 with shorts and opens 2 G-7 ED> Step 3: Measure length of both adapters plus through A D Z0Z through Step 4: Through length = l- S, -S, with respect to one-port standards 4. Three steps are necessary for achieving the unterminatlng technique, which measures transmission and reflection reference planes from a coaxial reference. Ps a 50-a, open-stub measurement and the reactances of the standards are shown in Fig. 1. Once the reactances of the standards are understood for a given probe placement, the probe s electrical length can be determined and the reference planes can be defined by relating electrical length to mechanical length. This was accomplished through utilization of three calibration techniques: scale modeling, short-open-load-through (SOLT), and through-reflect-line (TRL). A ZERO=LENGTH SHORT n order to determine the electrical length of a planar short standard, some assumptions must be made about what constitutes a zero- Knowing reactances of standards for probe placement, electrical length can be determined and reference planes defined. length short. TEM media with an infinite shorting wall provide a good model. For CPW, a conduction wall was used to approximate a zerolength short. The difference in electrical length between a wall short and a coplanar short can then be calculated. A loo-x-scale model was used to make the comparison (Fig. 2). A 0.4- ps delay was found for the coplanar short. This delay is equivalent to a 52-pm offset of the wall short, assuming a propagation velocity of 3. Reprnted wth permlsslon from Microwaves 8 RF - April 1988 Copyrght 1988 VNU Business Publications. nc.

D E S G N F E A T U R E 130 pm/ps. The next step is to relate this coplanar short delay to the actual shorting bar used on the SS (Fig. 3). These structures were realized in thin-film gold on 25-mil alumina. Probe overlap in each case is 1 mil. Linearity of the data through zero shows that the 0.4-ps delay holds for the shorting bar-probe combination. This exercise also confirms the propagation velocity at 130 pm/ps. Dispersion of the coplanar short was not observed and can be attributed to the small dimensions of the structure with respect to a wavelength. Coaxial standards, for example, may operate to within 90 percent of the frequency of the first waveguide mode. This permits significant evanescent moding to occur near the upper band edge. n contrast, the 0.4-ps delay of the coplanar short amounts to only l/50 of a wavelength at 50 GHz. TWO APPROACHES For two-port calibrations, a minimum-length coplanar through connection is added to the one-port standards. t is important that the reference planes for the reflection and transmission calibrations coincide. To verify the reference plane locations, two approaches were used: approximate unterminating and TRL calibration. Cascade Microtech has developed the approximate unterminating approach from the already established unterminating approach. n the unterminating approach (Fig. 4), a two-port coaxial calibration is used to characterize the electrical length of the probe on each port while it is terminated with a reflect standard. This length is compared with the length of both probes contacting a through standard. The two measurements then differ by the length of the through standard with respect to the reflect standard. However, imperfections in the probe generate first-order reflections that tend to obscure the delay information from the one-port measurennent. The approximate unterminating echnique was employed to improve he probe electrical length data. f.n assumption is made that the robe s output reflection coeffiient, S,,, is much less than 1, the 6. TRL calibration provides verification of the re!ference plane locations via use of these St andards. i-eflection coefficient equation may be simplified with a binomial expan- S ion (Fig. 5). The first-order reflection term is removed vectorially by S ubtracting the short from the open i-1eflection coefficients (hence the name approximate unterminatir1g"). The resulting signature corre- to the dispersion of the CPW Slponds ir1 the probe. This signature agrees very well with the transmission phase-mealineb @z25 ps Reflect > Probe in air ( Reference plane is placed in midpoint of shorter line, then rotated out 0.5 ps each. * Know reference planes from propagation velocity (e.g., 0.5 ps X 130 pm/ps - 65 km from midpoint). tep 3: Measure and store r,,, with r = -1 (short r Ls r Adapter s 12 Determining S,, of adapter itep 1: Calibrate in media A itep 2: Measure and store r,,, with r = 1 (open; -1 = s,, t s,: s,, t s;, Gsume S,, is much less than 1) ll * =s,, ts,: s,,-s;, tep 4: Subtract short from open A-r: = 2S2:...... -. - 5. n the approximate untermmanng- tecnmque, the firstorder reflection term is removed vectortally by subtracting the short from the open reflection coefficients. surement signature, allowing accurate subtraction of electrical lengths. The measured electrical length of the through standard is within ko.1 ps of the distance between the probe tips divided by the CPW phase velocity, when a 1-mil probe overlap is used. NDEPENDENT VERFCATON TRL calibrations were performed with an automatic vector network analyzer as an independent verification of the reference plane locations. The same 1-ps through standard, a 25-ps transmission line, and an open circuit were used as standards (Fig. 6). The reflect standards are computed as part of the TRL calibration when the through standard is used to set the reference plane. The only requirement is that the reflect offsets be the same for both ports. This permits the short or open standards to be measured after calibration. The phase of the short standard measured after a TRL calibration showed error of 0.03 ps. Although the TRL technique offers the most accuracy for delay measurements, it is directly linked

D E S G N F E A T U R E to the characteristic impedance, Z,, of the transmission line as an impedance standard. This is an advantage for TEM media such as coaxial line since accurate air-line standards can be realized. However, coplanar transmission lines are dispersive and will degrade impedance data. The dispersive Z, makes the lumpedresistive standards on the SS appear dispersive. Coupled lines 7. n the model of the probe overlap, the section of bond pad under the probe tip can be modeled as either a section of coupled line, or as mutual inductance and mutual capacitance in a lumped model. Coupling effects of probe tip and bond pad modifies electrical length of the probe and the reference plane. w For measurements on the wafer, the TRL technique can remove the offset uncertainty of SOLT standards used in later tests. The three methods produce reference plane measurements that agree to within +O.l ps, locating the reference plane from 0 to 1 mil beyond the contact tips (see table). n comparing these methods, a &5-pm probe placement error should be added to the measured numbers. n the model of the probe overlap on a DUT s bond pads (Fig. 7), the probe tip couples to the section of the bond pad directly underneath it. This can be modeled as a section of coupled line, or mutual inductance and mutual capacitance in a lumped model. This coupling effect modifies the electrical length of the probe and the reference plane. t is important to remove the repeatability variable by precise probe placement. As probe overlap is increased on a shorting plane, the effective electrical length decreases. This effect u25.urn overlap ElOO.um overlap Model from measured data 25 ph 25 ph Delay =k = 1 ps Delay = l/2( Zo C] = 0.375 ps Reference plane determination 8. The effects of overlap on twoqx~ri measurements are apparent when the degree of overlap is changed from 25 pm to 100 pm. Reference plane measured location Method Reference (in front of probe tip) Offset shorts Wall shcxt = zero length +27 ccrn Coax calibration with TEM standards set +4 pm unterminating approach reference plane TRL (LRL) rneflect 1 = rreflect2 +0 firm two-port measurements. A 1-ps through standard was measured with 1-mil overlaps, and an equiva- lent circuit was extracted. The through standard was then completely overlapped, effectively removing the series inductance and leaving only the shunt capacitance. The extracted equivalent circuit continues until an asymptote is reached at approximately -2-ps shortening, with 1-mil overlap defined as zero. Since the probe slopes away from the shorting plane, the coupling decreases to zero with further overlap, and therefore the effeet vanishes. Fie. 8 shows overlar, effects on

r D E S G N F E A T U R E shows no series inductance and a slight decrease in shunt capacitance caused by coupling with the probe. n FET measurement, this effect will manifest itself as variations in the parasitic gate and drain inductances, which can be extracted. The slight capacitance change is swamped by the much larger FET capacitance. Evidence of this effect can be illustrated when a FET is measured at the innermost edge of its 2-mil bond pads and corresponding equivalent circuit extraction, and then with the probes at the outermost edge of the bond pads (Fig. 9). The additional rotation in the input reflection coefficient, S,,, is apparent. Also, the equivalent circuit shows a 30-pH increase in the gate inductance, Lo, and drain inductance, LD, while the capacitances remain essentially constant. * (4 For Further Readinig ~ Eric Strid, Extract more accurate FE e uwalent cucults. MSN, Monohthic Technology Supp ement. Oct. 1987. pp. 3-7. Eric Strid, Planar impedance standards and accuracy considerations in vector network analysis. Proceedings ofthr Automatic RF Techniques Group, 1986 A CASCADE MCROTECH 9. n comparing FET pertormclnce measured at the innermost edge of the 2.mil pads (a), and then at the outermost edge (b), the increased S,, @ton is apparent, and the equivalent circutt shws a 3&pH increase in gate inductance and dmin mductance, while capacitances remain constant. (b)