SUPPORTING INFORMATION

Similar documents
Perfluorinated Alkyl Acids (PFAA) in Water by LC/MS/MS - PBM

Determination of Polyfluoroalkyl Substances (PFAS) in Food Products

ALLOWAY METHOD OUTLINE

United States EPA Method 415.3

Perfluorinated Alkyl Acids (PFAAs): Practical Answers to Frequently Asked Questions

Analysis of Low-Calorie Sweeteners by Liquid Chromatography-Tandem Mass Spectrometry

SECTION D.2 AMMONIA NITROGEN

Accreditation against multiple quality standards for legacy and emerging concern contaminants, including PFASs

METHOD 9210 POTENTIOMETRIC DETERMINATION OF NITRATE IN AQUEOUS SAMPLES WITH ION-SELECTIVE ELECTRODE

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

Determination of Cations and Amines in Hydrogen Peroxide by Ion Chromatography Using a RFIC (Reagent-Free) System

High Sensitivity HPLC Analysis of Perchlorate in Tap Water Using an Agilent 6460 Triple Quadrupole LC/MS System

1,2-Dibromoethane (EDB) and 1,2-dibromo-3-chloropropane (DBCP), gas chromatography, microextraction

METHOD 9200 NITRATE. 1.2 The applicable range of concentration is 0.1 to 2 mg NO -N per liter. 3 of sample.

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

METHOD 9252A CHLORIDE (TITRIMETRIC, MERCURIC NITRATE)

Revision: 11 (MBAS) ALLOWAY METHOD OUTLINE. Standard Laboratory Method:

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

High Throughput Water Analysis using Agilent 7900 ICP-MS coupled with ESI prepfast

Copyright ENCO Laboratories, Inc. II. Quality Control. A. Introduction

Application of Selenium Speciation Analysis to Elucidate Limitations with Accepted Total Selenium Methods

Glossary of Common Laboratory Terms

Supporting Information

INSTALLATION INSTRUCTIONS and TROUBLESHOOTING GUIDE. for the OnGuard- CARTRIDGE

Timberline Ammonia-001. Determination of Inorganic Ammonia by Continuous Flow Gas Diffusion and Conductivity Cell Analysis

ANALYSIS OF PERCHLORATE IN DRINKING WATER, GROUND WATER, SALINE WATER, SOIL, AND BIOTA BY LC/MSD

Schedule. Draft Section of Lab Report Monday 6pm (Jan 27) Summary of Paper 2 Monday 2pm (Feb 3)

METHOD 8032A ACRYLAMIDE BY GAS CHROMATOGRAPHY

Simple, reliable analysis of high matrix samples according to US EPA Method 6020A using the Agilent 7700x/7800 ICP-MS

Standard Operating Procedure for the Analysis of Chloride, Bromide and Sulfate in Fresh Waters by Ion Chromatography CCAL 50B.2

Water & Wastewater. Laboratory Math

METHOD 7196A CHROMIUM, HEXAVALENT (COLORIMETRIC)

The Agilent 7700x ICP-MS Advantage for Drinking Water Analysis

Fast Screening and Quantitation of Perfluorinated Sources from Textiles using Chemical Ionization GC-MS

Method Abstract. Flow Solution Fluoride, USGS by ISE and FIA

Determination of Inorganic Anions in Drinking Water by Ion Chromatography

Parameter Method Range # of Tests Code Page. Acidity (as % Oleic acid) titration % acidity 6 HI

Solubility Rules and Net Ionic Equations

A comparison between HRAM Orbitrap technology and MS/MS for the analysis of polyfluoroalkyl substances by EPA Method 537

A Technique for Determining Total Oxidizable Precursors (TOP) of Perfluoroalkyl Compounds

Version 1.0 October 2007

QA/QC in the Wastewater Laboratory. Steve Roberts Ohio EPA Division of Environmental Services 05/11/2016

METHOD 9035 SULFATE (COLORIMETRIC, AUTOMATED, CHLORANILATE)

METHOD 8030A ACROLEIN AND ACRYLONITRILE BY GAS CHROMATOGRAPHY

Chemistry. Approximate Timeline. Students are expected to keep up with class work when absent.

Hach Method Spectrophotometric Measurement of Free Chlorine (Cl 2 ) in Finished Drinking Water

Hach Method Total Organic Carbon in Finished Drinking Water by Catalyzed Ozone Hydroxyl Radical Oxidation Infrared Analysis

Radiological Traceability Program (RTP) Radiological and Environmental Science Laboratory (RESL) Svetlana Nour Kenneth Inn Jerry LaRosa Jackie Mann

Cyanide and sulfide analysis using amperometric detection and Metrosep A Supp /4.0

ALLOWAY STANDARD OPERATING PROCEDURES FOR METHOD 504.1/8011

A Fully Validated LC-MS/MS Method for Analysis of Trace Fluorotelomer Alcohols from Water

Analysis of Arsenic, Selenium and Antimony in Seawater by Continuous-Flow Hydride ICP-MS with ISIS

Determination of Hexavalent Chromium in Drinking Water Using Ion Chromatography

Trends of Perfluorinated Alkyl Substances in Herring Gull Eggs from Two Coastal. Colonies in Northern Norway:

Method to 0.50 mg/l NH 3 N Powder Pillows

The CLN Focus on Mass Spectrometry is supported by Waters Corporation

insoluble partial very soluble (< 0.1 g/100ml) solubility (> 1 g/100ml) Factors Affecting Solubility in Water

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

Application Note. Author. Abstract. Food Safety. Syed Salman Lateef Agilent Technologies, Inc. Bangalore, India

Inline sample preparation for the determination of anions in sodium hydroxide

Data Pack. Ion Chromatography Methods. June 2009

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

CHEM 200/202. Professor Jing Gu Office: EIS-210. All s are to be sent to:

Method to 0.50 mg/l NH 3 N Powder Pillows

Anion and Cation analysis with Professional IC - automatic dilution and sample preparation with SPM

Quick Review. - Chemical equations - Types of chemical reactions - Balancing chemical equations - Stoichiometry - Limiting reactant/reagent

1) What is the volume of a tank that can hold Kg of methanol whose density is 0.788g/cm 3?

Hach Company TNTplus 835/836 Nitrate Method Spectrophotometric Measurement of Nitrate in Water and Wastewater

Day 2 & Day 3 Online Video Reviews: Video Lesson # 1: Ionic Formulas; Using Criss-Cross Method

Determination of Inorganic Anions in Wastewater by Ion Chromatography

Appendix A. Glossary of Definitions, Acronyms, Abbreviations and Symbols. March 1997

Chlorine, Free and Total, High Range

Chlorine, Total. USEPA DPD Method 1 Method to mg/l as Cl 2 Chemkey Reagents. Test preparation. Before starting.

8 Laboratory of Environmental Pollution Control and Remediation Technology, Sun

Nitrate plus Nitrite and Nitrite in Seawater by Segmented Flow Analysis (SFA)

Evaluation of a novel glass vial overcoming adsorption effect for pharmaceutical drugs

Nitrogen, Ammonia. Test Preparation. Powder Pillows Method Method 8155 Salicylate Method 1 Powder Pillows

Samples compliant with the WATER

National Research Council Institute for Ecosystem Study Verbania Pallanza - Italy

METHOD DETERMINATION OF SULFATE BY AUTOMATED COLORIMETRY. Edited by James W. O'Dell Inorganic Chemistry Branch Chemistry Research Division

DETERMINATION OF PERCHLORATE IN DRINKING WATER BY LIQUID CHROMATOGRAPHY ELECTROSPRAY IONIZATION MASS SPECTROMETRY. Revision 1.

Persulfate Digestion Method Method to 25.0 mg/l N (LR) Test N Tube Vials

Persulfate Digestion Method Method to 150 mg/l N (HR) Test N Tube Vials

7. Stability indicating analytical method development and validation of Ramipril and Amlodipine in capsule dosage form by HPLC.

USGS Troy WSC Laboratory Ion Chromatography SOP EPA 300.0, Rev Jordan Road SOP. No. 1 Rev. No. 1.7 Troy, NY Date 01/25/18 Page 1 of 7

METHOD DEVELOPMENT FOR THE DETERMINATION OF SELECTED CYCLIC SILOXANES IN WASTEWATER AND SLUDGE AND STUDY OF THEIR HYDROLYSIS AT DIFFERENT TEMPERATURES

METHOD 7199 DETERMINATION OF HEXAVALENT CHROMIUM IN DRINKING WATER, GROUNDWATER AND INDUSTRIAL WASTEWATER EFFLUENTS BY ION CHROMATOGRAPHY

Standard Operating Procedures. Determination of Anions and/or Cations Extracted from Nylon Filters by Ion Chromatography (IC)

CHLORINE, FREE, Ultra-high Range ( mg/l Cl 2 ) Method 10069

Application Note #119 Alkalinity and Chloride by Titration

Chlorine, Free and Total, Low Range

METHOD 547 DETERMINATION OF GLYPHOSATE IN DRINKING WATER BY DIRECT-AQUEOUS- INJECTION HPLC, POST-COLUMN DERIVATIZATION, AND FLUORESCENCE DETECTION

High-Speed Environmental Analysis Using the Agilent 7500cx with Integrated Sample Introduction System Discrete Sampling (ISIS DS)

METHOD July J.W. Hodgeson. W.J. Bashe (Technology Applications Inc.) T.V. Baker (Technology Applications Inc.)

Appendix E: Water Management Strategy Support (Task 5.3.3) E.3 Ohio Trip Report

Practice Test 1 Bio 103 Name

DPD Test N Tube Method *

Per and Polyfluoroalkyl Substances (PFAS) in AFFF Formulations and Groundwater

Determination of Hormones in Drinking Water by LC/MS/MS Using an Agilent InfinityLab Poroshell HPH Column (EPA 539)

Exam Review. Chapters

Transcription:

SUPPORTING INFORMATION Method and Validation for the Analysis of Perfluorinated Compounds in Water by Pre-Sampling Isotope Dilution-Direct Injection- LC/MS/MS. Susan T. Wolf, William K. Reagen 1 2 30 3 40 Sample preparation and analyte adsorption During the validation of the method, it was observed that the internal standard (IS) and target analyte area counts were decreasing during the course of the run for PFDA, PFUnA, and PFDoA, when using clear 2-mL borosilicate glass autovials. This was the first time this was observed, since the method had been in use for several months with only occasional area response losses noticed for PFDoA. After reviewing all aspects of the analysis to determine the possible source of decreasing response, it was determined that the change in the IS area count response for these analytes was not instrument or solvent related, but had to be the result of a change in the preparation of the samples. Since the only sample preparation step for this method involved 1:1 dilution of the sample with methanol, the 2mL glass autovial used in the laboratory was investigated. The autovials that were investigated included 2-mL borosilicate clear glass autovials manufactured by Agilent (stock number 182-043), silanized 2-mL borosilicate clear glass autovial from Agilent (stock number 183-449) and 1-mL polypropylene autovials from National Scientific (stock number C4011-14). To evaluate the possible effects due to autovial type, the method validation samples, prepared in laboratory reagent water (Milli-Q water generated from a Milli-Q water system from Millipore Corporation, containing hardness at 16 mg equivalent CaCO 3 L -1 ) were diluted 1:1 with methanol into each of the three vial types. A comparison of the IS area counts for the four different sample types; calibration standards, continuing calibration verification samples, method blanks, and method validation samples, were evaluated during the course of a 36 hour analytical run. An RSD <% was considered acceptable, based on method acceptance criteria regarding precision, with similar results observed for the target analyte area response. The RSD results are shown in Table 1 and demonstrate that the autovial type; borosilicate glass, silanized glass or polypropylene, has an effect on area count stability for PFDA, PFUnA, and PFDoA when analyzing a well-mixed water sample aliquot diluted 1:1 with methanol in an autovial. Similar observations were made for samples diluted 1:1 with methanol into amber 2- ml borosilicate glass autovials and analyzed for PFOS. A series of seventy-eight samples were analyzed in amber 2-mL borosilicate glass autovials with the [13C4]PFOS surrogate recovery standard (SRS) having a peak area RSD of 49% while the [13C8]PFOS IS peak area RSD was 48%. When these same samples were diluted 1:1 with methanol into 1-mL polypropylene autovials analyzed for PFOS, the peak area RSD for the [13C4] PFOS surrogate was 17% while the [13C8]PFOS IS peak area RSD was %.

Table 1. Evaluation of autovial types for the analysis of water samples diluted 1:1 with methanol for PFDA, PFUnA, and PFDoA. Samples analyzed during a 36 hour analytical run Internal Standard Area Count RSD 2 ml clear borosilicate glass vial [13C6]PFDA [13C7]PFUnA [13C2]PFDoA RSD of initial calibration curve (n=1) 17 39 73 RSD of CCV samples (n=4) 42 132 186 RSD of method blank (n=1) 73 129 13 RSD of control samples (n=23) 44 64 88 Internal Standard Area Count RSD 2 ml silanized glass vial [13C6]PFDA [13C7]PFUnA [13C2]PFDoA RSD of initial calibration curve (n=1) 8.7 11 13 RSD of CCV samples (n=4) 11 18 12 RSD of method blank (n=1) 9. 1 27 RSD of control samples (n=23) 12 13 24 Internal Standard Area Count RSD 1 ml polypropylene vial [13C6]PFDA [13C7]PFUnA [13C2]PFDoA RSD of initial calibration curve (n=1) 11 14 12 RSD of CCV samples (n=4) 7.2 RSD of method blank (n=1) 4.7.9 7. RSD of control samples (n=23) 8. 7.3 21 1 Matrix Effect Early efforts at developing a direct injection analysis method for local municipal drinking water found that samples were often not meeting the method acceptance criteria for FMS recovery (0%±30%) for PFOS when analyzed against an IS calibration curve prepared in laboratory Milli-Q water. It was found that there was an approximate 30% difference in the peak area response for PFOS in a 1ppb control sample prepared in carbon filtered municipal drinking water as compared to a 1ppb standard of PFOS in laboratory Milli-Q water. Based on limited information on the water chemistry (i.e. hardness, alkalinity, sulfate, iron, potassium), an investigation into the effect of anions and cations present in groundwater matrices was evaluated. Control samples were prepared in laboratory Milli-Q water containing various salts of Mg 2+, Ca 2+, sulfate (SO - 4 ), carbonate (CO - 3 ), and chloride (Cl - ) to evaluate matrix effects. The results of the evaluation showed that the cations Mg 2+ and Ca 2+ appear to suppress the analyte signal for PFOS by ~30-40% when analyzed against a calibration curve prepared in Milli-Q water. Data from this investigation was presented in a poster titled Development and Utilization of a Large-Volume Direct Injection LC/MS/MS Method for the Analysis of PFCs in Water at the SETAC North America 29 Th Annual Meeting in Tampa bay Florida in 08.

1 2 Laboratory reagent water was prepared by adding 2 mg L -1 Mg 2+ (as magnesium acetate) and 2 mg L -1 Ca 2+ (as calcium acetate) to Milli-Q water to produce a calculated water hardness of 16 mg L -1, similar to what was observed in local municipal drinking water. 1 The use of laboratory reagent water for the preparation of calibration standards improved the recoveries for target analyte FMS samples for groundwater matrices when analyzed by direct injection (DI) analysis. The development of the validated DI-LC/MS/MS analytical method presented herein included the use of 1:1 laboratory reagent water and methanol, which stabilized the low level calibration standards for the long chain PFCAs, extending the use of the calibration curve. To demonstrate the effects that matrix matched calibration standards, the use of IS, and solvent dilution, has on PFOS recovery in environmental water samples, a series of control samples were prepared in chlorinated (1 mg L -1 ), ph 8 water for organic analysis (water harness of 0 mg L -1 ), as specified in ANSI-NSF Standard 61 section B.9.6. 2 The control samples were analyzed against a calibration curve prepared in laboratory Milli-Q water containing IS, and prepared with and without 1:1 dilution with methanol. Control samples were evaluated by both IS calibration and external calibration. The effectiveness of matrix dilution and IS use on accuracy and precision can be found in Table 2. The data shows that when samples containing 0 mg L -1 hardness are analyzed for PFOS by external standard calibration against a curve prepared in Milli Q water, recoveries for PFOS range from 43.8% - 70.6%. The use of IS brings the recovery for PFOS to 119-124%. By diluting the samples 1:1 with methanol, the matrix effects associated with a water harness of 0 mg L -1 are eliminated regardless of whether the samples are quantitated by internal or external standard calibration, with recoveries ranging from 90.3 9%. In addition to 1:1 dilution with methanol, the use of an IS specific for PFOS, in this case [13C8]PFOS, appears to correct for these matrix effects.

Table 2. recovery and precision for PFOS to evaluate matrix effects a. Analyte Spike level ng ml -1 Direct Inject IS calibration Recovery RSD Direct Inject External calibration Recovery RSD 1:1 dilution with methanol IS calibration Recovery RSD 1:1 dilution with methanol External calibration Recovery RSD Chlorinated NSF 61, ph 8 water (0 mg L -1 hardness) with sodium thiosulfate addition PFOS 0.0922 124 3.3 1.8 12 4 4.0 90.3 2.8 PFOS 0.922 119 2.1 8. 8.1 1 1.1 97.1 2.7 PFOS 9.22 119 0.48 70.6 3.1 2 0.0 6 4.1 13 C 4 -PFOS 0.090 123 1.6 46.4 16 8 4.6 92.2 4. 13 C 4 -PFOS 0.90 118 2.6 2.2 8.2 1 2.8 96.9 3.3 Chlorinated NSF 61, ph 8 water (0 mg L -1 hardness) without sodium thiosulfate addition PFOS 0.0922 122 1.7 43.8 3.7 98.8 1.1 90.8 2.7 PFOS 0.922 122 1.3 4.6 1 0 2.2 94.1 4.2 PFOS 9.22 122 0.47 64.8 12 1 0.7 9.6 13 C 4 -PFOS 0.090 122 3.1 38.7.9 3 3.4 93.3 0.81 13 C 4 -PFOS 0.90 121 0.83 48.7 17 1 1.1 9.0 3.4 a Control samples were prepared in triplicate (n=3) at each spiking level in ANSI-NSF Standard 61 ph 8 water with hardness = 0 mg L -1 as calcium carbonate and chlorinated at 1 mg L -1. Control samples were analyzed against a calibration curve prepared in laboratory Milli-Q water and evaluated by IS calibration and external calibration. Control samples were analyzed with and without 1:1 dilution with methanol. 1 2 The use of laboratory reagent water was added to the method as a means to address the signal suppression that was observed due to matrix effects on PFDA, PFUnA, and PFDoA and the signal enhancement that was observed for FOSA. Table 3 demonstrates these matrix effects in a side by side comparison of the analyte peak area of fortified Milli-Q water and laboratory reagent water. Control samples were prepared at three concentration levels in triplicate in high density polyethylene (HDPE) containers and diluted 1:1 with methanol into 1 ml polypropylene autovials. Peak area suppression in hard water relative to Milli-Q water was observed for PFDA (16%), PFUnA (40%), [13C2]PFUnA SRS (38%) and PFDoA (3%). The same observation trends were made for the IS peak area for [13C2]PFDA (1%), [13C7]PFUnA (40%), and [13C2]PFDoA (%). Peak signal enhancement was observed for PFOSA (2%) and the IS peak [13C8]PFOSA (30%). What this demonstrates is that the use of isotopically-labeled analogues of the PFC method analytes is critical for accurate quantitation of water samples that contain these matrix components. In addition to analyte suppression or enhancement, the use of these ISs can also account for analyte adsorption of longer chain PFCA analytes, as was reported by Berger et. al (11). 3 As Berger notes, losses of more than 30% were observed for PFUnA and PFDoA after 28 days. These findings highlight that an IS, when applied incorrectly, can potentially bias analytical results. For example, it would not be appropriate to quantitate water samples for PFUnA and PFDoA that have high hardness levels, with the [13C2]PFDA IS, due to the

differences in matrix effects that would bias the samples results low. Table 3. Effects from matrix (water hardness); suppression or enhancement on analyte response. Control Samples a Analyte Peak Area Milli Q water Peak Area laboratory reagent water % difference due to matrix b 0.1 ng ml -1 (average n=3) PFDA 27298 2904-14 1 ng ml -1 (average n=3) PFDA 2719337 29074-19 ng ml -1 (average n=3) PFDA 2444301 97227-14 Average -16 0.1 ng ml -1 (average n=3) [13C2]PFDA-IS 0480 1776440-11 1 ng ml -1 (average n=3) [13C2]PFDA 21648 171339-19 ng ml -1 (average n=3) [13C2]PFDA 7083 176762-14 Average -1 0.1 ng ml -1 (average n=3) PFUnA 182963 12346-32 1 ng ml -1 (average n=3) PFUnA 191741 73464-44 ng ml -1 (average n=3) PFUnA 18629264 6898-43 Average -40 0.1 ng ml -1 (average n=3) [13C2]PFUnA-SRS 14332 97434-32 1 ng ml -1 (average n=3) [13C2]PFUnA-SRS 132816 80900-44 Average -38 0.1 ng ml -1 (average n=3) [13C7]PFUnA-IS 1307777 88604-32 1 ng ml -1 (average n=3) [13C7]PFUnA-IS 1398317 76314-4 ng ml -1 (average n=3) [13C7]PFUnA-IS 148421 81277-44 Average -40 0.1 ng ml -1 (average n=3) PFDoA 14311 8238-4 1 ng ml -1 (average n=3) PFDoA 168431 70613-8 ng ml -1 (average n=3) PFDoA 16006981 6876068-7 Average -3 0.1 ng ml -1 (average n=3) [13C2]PFDoA-IS 1166829 622247-47 1 ng ml -1 (average n=3) [13C2]PFDoA-IS 1280663 32713-8 ng ml -1 (average n=3) [13C2]PFDoA-IS 1361 4776-9 Average - 0.1 ng ml -1 (average n=3) PFOSA 8146 91980 1 1 ng ml -1 (average n=3) PFOSA 838944 4306 27 ng ml -1 (average n=3) PFOSA 64293 81192 33 Average 2 0.1 ng ml -1 (average n=3) [13C8]PFOSA-IS 72801 893489 26 1 ng ml -1 (average n=3) [13C8]PFOSA-IS 77091 12923 32 ng ml -1 (average n=3) [13C8]PFOSA-IS 607148 79496 32 Average 30 a Control samples were prepared in triplicate in HDPE containers in either laboratory Milli-Q water or laboratory reagent water. Control samples were prepared at 0.1, 1, and ng ml -1, with all samples pre-spiked with an IS mix at 1 ng ml -1. An aliquot was removed and diluted 1:1 with methanol into a 1-mL polypropylene autovial just prior to sample analysis. b To determine matrix suppression, the percent difference was calculated by subtracting the average analyte peak area for the control samples in laboratory Milli-Q water from the average analyte peak area for the control samples in laboratory reagent water and dividing by the average analyte peak area for the control samples in laboratory Milli-Q water.

1 EPA Method 37 comparison with DI-LC/MC/MC method Analysis of PFC method analytes in chlorinated, ph 8 drinking water was conducted to compare the recovery of control samples analyzed by the DI-LC/MS/MS method and EPA Method 37. Control samples were prepared in 0mLs of synthetic chlorinated drinking water at ph 8. Two sets of five replicate samples were fortified with PFCAs (C6-C12) and PFSAs (C4, C6, and C8), at 0.1 ng ml -1. Sample containers for control samples to be analyzed by the DI-LC/MS/MS method were pre-spiked with ISs at 1 ng ml -1 and SRSs [ 13 C 4 ]PFOA, [ 13 C 2 ]PFUnA, and [ 13 C 4 ]PFOS at 0.1 ng ml -1. Both sets of samples were held for 7 days prior to analysis by DI-LC/MS/MS and EPA Method 37. At day 7, the control samples analyzed by EPA Method 37, the SRSs were added at 0.1 ng ml -1 just prior to sample extraction. The concentrated extract was diluted 1: with methanol, fortifed with ISs 1 ng ml -1 and analyzed against a 96:4% (vol/vol) methanol: water curve from 0. 1 ng ml -1. At day 7, the control samples analyzed by DI- LC/MS/MS were diluted 1:1 with methanol and analyzed against a calibration curve prepared in 0:0 laboratory reagent water:methanol. The mean recoveries for the PFC method analytes analyzed by DI-LC/MS/MS ranged from 88.4-9.7% (77.6-87.8% for SRSs). The mean recoveries for the PFC method analytes analyzed by EPA Method 37 ranged from 91.6-% (86.2-90.4% for SRSs) (Figure 1). The average absolute difference between the EPA Method 37 and DI-LC/MS/MS measurements for the method analytes and SRSs was 8%. EPA 37 DI LC/MS/MS % Recovery 1.0 0.0 80.0 60.0 40.0.0 0.0 Figure 1. Recovery of Control Samples (n=) prepared at 0.1 ng ml -1 in Synthetic 2 Chlorinated Drinking Water and analyzed by EPA 37 and DI-LC/MS/MS. 1 2 3 Eaton, A. D.; Clesceri, L. S.; Greenberg, A. E., Eds. Standard Methods for the Examination of Water and Wastewater, 19th ed.; American Public Health Association: Washington, DC, 199; Physical & Aggregate Properties, Part 2340 B, p 2-36. NSF International Standard / American National Standards Institute, Drinking Water System Components Health Effects, NSF/ANSI 61, http://www.nsf.org, 11. U. Berger, M.A. Kaiser, A. Karrman, J.L. Barber, S.P.J. van Leeuwen, Recent developments in trace analysis of poly- and perfluoralkyl substances, Anal. Bioanal. Chem, 11, 400, 162-163.