POLYDEXTROSES. SYNONYMS Modified polydextroses; INS No DEFINITION DESCRIPTION. FUNCTIONAL USES Bulking agent, humectant, stabilizer, thickener

Similar documents
ASPARTAME. Not less than 98% and not more than 102% on the dried basis. White, odourless, crystalline powder, having a strong sweet taste

TERTIARY BUTYLHYDROQUINONE

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.

Sulfotepp impurities in Chlorpyrifos EC formulations

POLYVINYL ALCOHOL. SYNONYMS Vinyl alcohol polymer, PVOH, INS No DEFINITION DESCRIPTION FUNCTIONAL USES CHARACTERISTICS

Tex-620-J, Determining Chloride and Sulfate Contents in Soil

LEAD (Colorimetric) 2. Muffle Furnace: Equipped with pyrometer and capable of operating at controlled temperatures up to 500 C

ETHYL HYDROXYETHYL CELLULOSE

Direct Determination of Aluminium in Milk by Graphite Furnace Atomic Absorption Spectrometry

Sodium Chloride - Analytical Standard

CHAPTER - 3 ANALYTICAL PROFILE. 3.1 Estimation of Drug in Pharmaceutical Formulation Estimation of Drugs

Anethole. Gas chromatograhpy determination of trans-anethole in Spirit srinks of viti-vinicultural origin

Determinations by Atomic Absorption Spectroscopy and Inductively Coupled Plasma-Atomic Emission

H 3 CO H 3 CO S CH 3

Determination of Orthophosphate Ion

ADVANTAME. Not less than 97.0% and not more than 102.0% on the anhydrous basis. Sweetener, flavour enhancer

1,2-Dibromoethane (EDB) and 1,2-dibromo-3-chloropropane (DBCP), gas chromatography, microextraction

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.

Sodium Chloride - Analytical Standard

Technical Procedure for Concentration Determination of Methamphetamine in Liquids via HPLC

Annex 2 Formaldehyde

637. Thiamethoxam. HPLC method

Title Revision No date DETERMINATION OF HEAVY METALS (ARSENIC, CADMIUM, LEAD AND MERCURY) IN COSMETIC PRODUCTS

12 Nicarbazin Nicarbazin (4,4 -dinitro carbanilid (DNC) and 2-hydroxy-4,6-dimethyl pyrimidine (HDP))

GAFTI Analytical method for ISO/TS 16179:2012 Detection and Determination of Organotin Compounds in Footwear and Apparel Materials by GC-MS

The analysis of organic acid content of additives, premix, feed, and water.

Direct Determination of Cadmium and Lead in honey by Electrothermal Atomization Atomic Absorption Spectrometry with Zeeman Effect Correction

Cyanide, colorimetric, pyridine-pyrazolone

ADVANTAME (TENTATIVE)

Determination of Orthophosphate Ion

1. A gas chromatograph equipped with flame ionization detection and a computing integrator.

CALCIUM LIGNOSULFONATE (40-65)

Determination of Polymer Modifier in Asphalt

Determination of Pb, Cd, Cr and Ni in Grains Based on Four Chinese National Methods via Zeeman GFAAS

NOTICE: This method: The laboratories have to study the instrumental conditions appropriate for their own instrumentation.

BRIEFING. Pharmacopeial Discussion Group Sign Off Document Attributes EP JP USP Definition Loss on drying Readily carbonizable substances

Diquat 1,1 -ethylene-2,2 -bipyridium dibromide salt Paraquat 1,1 -dimethyl-4,4 -bipyridium dichloride salt Initial Preparation

PYRIPROXYFEN TECHNICAL

For Research Use Only

Exercise 6: Determination of Hardness of Water

CYCLOSERINE Final text for addition to The International Pharmacopoeia. (November 2008) CYCLOSERINUM CYCLOSERINE

Draft Method proposal: determination of glucoheptonic acid (HGA) in fertilizers.

The Nitrofurantoin Capsules Revision Bulletin supersedes the currently official monograph.

SpeedDigester K-436, K-439 Determination of Hydroxyproline in Meat after Acid Hydrolyzation (Photometric method)

Report AFK0242/18 TABLE OF CONTENTS

Determination of Carbonyl Compounds In Water by Dinitrophenylhydrazine Derivatization and HPLC/UV*

LUMEFANTRINUM LUMEFANTRINE

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF THE

TECHNICAL TEMEPHOS. 1. Specification. Full specification WHO/SIT/19.R4 Revised 10 December Description

CIPAC. CIPAC Free relevant impurities methods:

METHOD 8032A ACRYLAMIDE BY GAS CHROMATOGRAPHY

DISCLAIMER: This method:

Cadmium Reduction Method Method to 0.50 mg/l NO 3 N (LR) Powder Pillows

Ondansetron Hydrochloride Tablets

IDENTIFICATION AND DETERMINATION OF HYDROQUINONE IN COSMETIC PRODUCTS 2 14/11/17 ACM 003 BY TLC AND HPLC

DRAFT EAST AFRICAN STANDARD

TECHNICAL BRODIFACOUM

IDENTIFICATION OF STEROIDS IN COSMETIC PRODUCTS BY TLC AND HPLC 1 02/12/2005 ACM 007 A. THIN LAYER CHROMATOGRAPHY (TLC)

INDIGOTINE. Disodium 3,3'-dioxo-[delta 2,2' -biindoline]-5,5'-disulfonate (principal component) (principal component)

METHOD 8033 ACETONITRILE BY GAS CHROMATOGRAPHY WITH NITROGEN-PHOSPHORUS DETECTION

Corn Sugar (crude & refined) Analysis F MOISTURE (Karl Fischer)

5. SEPARATION OF MIXTURES, PURIFICATION OF SOLIDS Objectives

Determination of an Equilibrium Constant

SOIL ORGANIC CONTENT USING UV-VIS METHOD

METHOD 3510B SEPARATORY FUNNEL LIQUID-LIQUID EXTRACTION

National Research Council Institute for Ecosystem Study Verbania Pallanza - Italy

USP 35 Official Monographs / Oxaliplatin 4143 DEFINITION

Experiment 3. Condensation Reactions of Ketones and Aldehydes: The Aldol Condensation Reaction.

Citric Acid Analysis L-6-1. MOISTURE (Karl Fischer)

BRIEFING. (EM2: K. Moore.) RTS C Add the following: Methylcellulose

Mercury, total-in-sediment, atomic absorption spectrophotometry, nameless, direct

STANDARD OPERATING PROCEDURES SOP: 1828 PAGE: 1 of 14 REV: 0.0 DATE: 05/12/95 ANALYSIS OF METHYL PARATHION IN CARPET SAMPLES BY GC/MS

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT

Nitrogen, ammonia, colorimetry, salicylate-hypochlorite, automated-segmented flow

METHOD: 1403, Issue 3 EVALUATION: FULL Issue 1: 15 August 1990 Issue 3: 15 March 2003

SPECIFICATION & TEST PROCEDURE SODIUM SALICYLATE Technical. Molecular weight : Reference : In-house

Anion and Cation analysis with Professional IC - automatic dilution and sample preparation with SPM

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

A Spectrophotometric Analysis of Calcium in Cereal

CHAPTER V ANALYTICAL METHODS ESTIMATION OF DICLOFENAC. Diclofenac (gift sample from M/s Micro Labs Ltd., Pondicherry)

METHOD 7060A ARSENIC (ATOMIC ABSORPTION, FURNACE TECHNIQUE)

This method describes the identification of the following prohibited colorants in cosmetic products:

Quality Control Procedures for Graphite Furnace AAS using Avanta Software

METHOTREXATE mg/m 3 (arbitrary). There is no OSHA PEL or AGGIH TLV for

BRIEFING. (EXC: K. Moore.) RTS C Propylparaben C 10 H 12 O Benzoic acid, 4 hydroxy, propyl ester; Propyl p hydroxybenzoate [ ].

Chemistry 283g- Experiment 4

METHOD 7196A CHROMIUM, HEXAVALENT (COLORIMETRIC)

STANDARD OPERATING PROCEDURES SOP: 1826 PAGE: 1 of 18 REV: 0.0 DATE: 03/30/95 ANALYSIS OF METHYL PARATHION IN WIPE SAMPLES BY GC/MS

GB/T Translated English of Chinese Standard: GB/T

Corn Syrup Analysis E-51-1 PHOSPHORUS

Cadmium Reduction Method Method to 10.0 mg/l NO 3 N (MR, spectrophotometers) 0.2 to 5.0 mg/l NO 3 N (MR, colorimeters)

METHOD 9200 NITRATE. 1.2 The applicable range of concentration is 0.1 to 2 mg NO -N per liter. 3 of sample.

APPENDIX A TO PART 136 METHODS FOR ORGANIC CHEMICAL ANALYSIS OF MUNICIPAL AND INDUSTRIAL WASTEWATER METHOD 609 NITROAROMATICS AND ISOPHORONE

METHOD 3520B CONTINUOUS LIQUID-LIQUID EXTRACTION

Additionally, minor editorial changes have been made to update the monograph to current USP style.

Microdetermination of phosphorus using the SPECTRAmax PLUS microplate spectrophotometer: choice of microplate, cuvette or test tube assay formats

CHEM 334 Quantitative Analysis Laboratory

LACTIC ACID. The method is applicable to the determination of lactic acid and lactate salts (Note 2) in light or heavy steepwater.

DR/4000 PROCEDURE SELENIUM. 4. Measure 100 ml of sample into a second 500-mL erlenmeyer flask (label the flask sample ).

Final Report. Characterisation of Sample Report. Job No 2016/11/12-34 AS No. 1234A. Client Example Contact Sample. Signed Date 2017.

Transcription:

POLYDEXTROSES Prepared at the 51st JECFA (1998) and published in FNP 52 Add 6 (1998) superseding specifications prepared at the 44th JECFA (1995), published in FNP 52 Add 3 (1995). An ADI "not specified" was established at the 31st JECFA in 1987. SYNONYMS Modified polydextroses; INS No. 1200 DEFINITION Randomly bonded condensation polymers of glucose with some sorbitol end-groups, and with citric acid or phosphoric acid residues attached to the polymers by mono or diester bonds. They are obtained by melting and condensation of the ingredients which consist of approximately 90 parts D-glucose, 10 parts sorbitol and up to 1 part citric acid or 0.1 part phosphoric acid. The 1,6-glucosidic linkage predominates in the polymers but other linkages are present. The products contain small quantities of free glucose, sorbitol, levoglucosan (1,6-anhydro-D-glucose) and citric acid and may be neutralized with any food-grade base and/or decolourized and deionized for further purification. The products may also be partially hydrogenated with Raney nickel catalyst to reduce residual glucose. Polydextrose-N is neutralized Polydextrose. C.A.S. number 68424-04-4 Assay DESCRIPTION Not less than 90.0% of polymer on the ash-free and water-free bases White to light tan-coloured solid. Polydextroses dissolve in water to give clear, colourless to straw-coloured solutions FUNCTIONAL USES Bulking agent, humectant, stabilizer, thickener CHARACTERISTICS IDENTIFICATION Solubility (Vol. 4) Test for sugar Solubility in acetone Test for reducing sugar Very soluble in water To 1 drop of 1 in 10 solution of the sample, add 4 drops of 5% phenol solution, then rapidly add 15 drops of sulfuric acid TS. A deep yellow to orange colour is produced. With vigorous swirling add 1 ml of acetone to 1 ml of a 1 in 10 solution of the sample. The solution remains clear. With vigorous swirling add 2 ml of acetone to the solution. A heavy, milky turbidity develops immediately. To 1 ml of a 1 in 50 solution of the sample, add 4 ml of alkaline cupric citrate TS. Boil vigorously 2-4 min. Remove from heat and let precipitate (if any) settle. The supernatant is blue or blue-green. PURITY Water (Vol. 4) Not more than 4.0% (Karl Fischer Method)

ph (Vol. 4) Sulfated ash (Vol. 4) Nickel (Vol. 4) 1,6-Anhydro-D-glucose Glucose and sorbitol 2.5-7.0 (for Polydextrose) (1 in 10 soln) 5.0-6.0 (for Polydextrose-N) (1 in 10 soln) Not more than 0.3% (for Polydextrose) Not more than 2.0% (for Polydextrose-N) Not more than 2 mg/kg for hydrogenated polydextroses Use method Nickel for polyols Not more than 4.0% on the ash-free and the dried bases Not more than 6.0% combined on the ash-free and the dried bases; glucose and sorbitol are determined separately Molecular weight limit Negative to test for polymer of molecular weight greater than 22,000 5-Hydroxymethylfurfural Lead (Vol. 4) Not more than 0.1% in Polydextrose Not more than 0.05% in Polydextrose-N Not more than 0.5 mg/kg Determine using an atomic absorption technique appropriate to the specified level. The selection of sample size and method of sample preparation may be based on the principles of the method described in Volume 4, Instrumental Methods. TESTS PURITY TESTS Lead (Vol. 4) Apparatus: Use a suitable atomic absorption spectrophotometer (Perkin-Elmer Model 6000, or equivalent), a graphite furnace containing a L'vov platform (Perkin-Elmer Model HGA-500, or equivalent), and an autosampler (Perkin-Elmer Model AS-40, or equivalent). Use a lead hollow cathode lamp (lamp current of 10 ma), a slit width of 0.7 mm (set low), the wavelength set at 283.3 nm, and a deuterium arc lamp for background correction. Use argon as the carrier gas. (Note: For this test use reagent-grade chemicals with as low a lead content as practicable, as well as high-purity water and gases. Before use, rinse all glassware and plasticware twice with 10% nitric acid and twice with 10% hydrochloric acid, and then rinse thoroughly with high-purity water.) Lead Nitrate Stock Solution: Dissolve 159.8 mg of reagent-grade lead nitrate in 1000.0 ml of water. Prepare and store this solution in glass containers that are free from lead salts. Each ml of this solution contains the equivalent of 100 µg of lead ion. Standard Lead Solution:

On the day of use, dilute 10.0 ml of Lead Nitrate Stock Solution with water to 100.0 ml, and mix. Each ml of Standard Lead Solution contains the equivalent of 10 µg of lead ion. Standard Solutions: Prepare a series of lead standard solutions serially diluted from the Standard Lead Solution. Into separate 100 ml volumetric flasks, pipet 0.2, 0.5, 1, 2 ml, and 5 ml, respectively, of Standard Lead Solution, dilute to volume with water, and mix. The Standard Solutions contain, respectively, 0.02, 0.05, 0.1, 0.2, and 0.5 µg of lead per ml. Matrix Modifier: Transfer 100.0 mg of ammonium phosphate, dibasic ((NH 4 ) 2 HPO 4 ) to a 10 ml volumetric flask, dilute to volume with water, and mix. Sample Solution: Transfer about 1 g of the sample, accurately weighed, to a 10 ml volumetric flask, add 5 ml of water, and mix. Dilute to volume with water, and mix. Spiked (fortified) Sample Solution: Prepare a solution as directed under Sample Solution, but add 100 µl of the Standard Lead Solution, dilute to volume with water, and mix. This solution contains 0.1 µg/ml of added lead. : With the use of an autosampler, atomize 10-µl aliquots of the five Standard Solutions, using the following sequence of conditions: step (1) dry at 130 o with a 20-sec ramp period, a 40-sec hold time, and a 300 ml/min argon flow rate; step (2) char at 800 o with a 20-sec ramp period, a 40-sec hold time, and a 300 ml/min argon flow rate; step (3) atomize at 2400 o for 6 sec with a 50 ml/min argon flow rate, and read; step (4) clean at 2600 o with a 1-sec ramp period, a 5-sec hold time, and a 300 ml/min argon flow rate; and step (5) recharge at 20 o with a 2-sec ramp period, a 20-sec hold time, and a 300 ml/min argon flow rate. Atomize 10 µl of the Matrix Modifier in combination with 10 µl of the Sample Solution under identical conditions used for the Standard Solutions. Repeat with 10 µl of the Matrix Modifier in combination with 10 µl of the Spiked Sample Solution. Plot a standard curve using the concentration, in µg/ml, of each Standard Solution versus its maximum absorbance value compensated for background correction, and draw the best straight line. From the Standard Curve, determine the concentrations C S and C A in µg/ml, of the Sample Solution and the Spiked Sample Solution, respectively. Calculate the quantity, in mg/kg, of lead in the sample by the formula: W = the weight, in g, of the sample taken. Calculate the recovery by the formula:

0.1 = the amount of lead, in µg/ml, added to the Spiked Sample Solution. 1,6-Anhydro-D-glucose, glucose and sorbitol Gas chromatography - Octadecane Solution: Accurately weigh 50 mg of n-octadecane into a 100-ml volumetric flask and make up to volume with pyridine. - Monomer Standard Solution: Weigh accurately 50 mg reagent grade alpha-d-glucose, 40 mg anhydrous D-sorbitol (min. 97% purity), and 35 mg of reagent grade (1,6-anhydro-D-glucose), into a 100-ml volumetric flask and make up to volume with pyridine. Silylation of Monomer Standard Solution Transfer 1.0 ml of Monomer Standard Solution to a screw-cap vial and add 1 ml of Octadecane Solution and 0.5 ml of N-trimethylsilylimidazole. Cap the vial and immerse in an ultrasonic bath at 70 o for 60 min. Gas Chromatograph conditions Glass column, 2.44 m by 2 mm i.d. packed with 3% OV-1 on Gas Chrom Q 100/120 mesh. Flame ionization detector. Temperatures: column 175 o ; injection port 210 o ; detector 230 o. Retention times (min): 1,6-anhydro-Dglucose, pyranose form 3.7; 1,6-anhydro-D-glucose furanose form (not present in standard) 4.3; n-octadecane 5.1; alpha-d-glucose 8.7; D- sorbitol 11.3; beta-d-glucose 13.3. Accurately weigh 20 mg of the sample into a screw-cap vial and add 1.0 ml of Octadecane Solution, 1 ml of pyridine, and 0.5 ml of N- trimethylsilylimidazole. Cap the vial and immerse in an ultrasonic bath at 70 o for 60 min. Prior to sample analysis, inject 3 µl of the silylated Monomer Standard Solution into the gas chromatograph. Repeat two times, then inject 3 µl of the sample solution. Calculate the percentage of each monomer by the formula: W = the weight of the sample in mg, adjusted for ash and moisture W S = the weight in mg of the monomer in the Monomer Standard Solution R = the ratio of the area of the monomer peak to the area of the octadecane peak in the sample injection R S = the mean ratio of the area of the monomer peak to the area of the octadecane peak in the standard injections. In the case of glucose, the peak areas for the alpha- and beta-epimers and in the case of 1,6-anhydro-D-glucose the peak areas for the pyranose form and furanose form are combined. Molecular weight limit Apparatus Use a suitable high-pressure liquid chromatograph (HPLC) equipped with a differential refractometer, either a loop injector or suitable autosampler,

a column heating block or oven and a computing integrator, or computer data handling system with molecular weight determination capabilities. Use a Waters Ultrahydrogel 250 A size exclusion column, or equivalent. The column is maintained at 45 o, and the HPLC pump supplies eluent to it at 0.8 ml/min reproducible to 0.5%. The differential refractometer should be set at a sensitivity of 4 x 10-6 refractive index units full scale, and the plotter of the integrator should be set to 64 millivolts full scale. Maintain the detector cell at 35±0.1 o. Noise attributable to the detector and electronics should be less than 0.1% full scale. Eluent The eluent is 0.1 N sodium nitrate containing 0.025% sodium azide. Dissolve 35.0 g of sodium nitrate and 1.0 g of sodium azide in 100 ml of HPLC-grade water. Filter through a 0.45-µm filter into a 4-l flask. Dilute to volume with HPLC-grade water. De-gas by applying an aspirator vacuum for 30 min. Standard Solution Transfer 20 mg each of dextrose, stachyose, 5800, 23,700, and 100,000 MW pullulan standards into a 10-ml volumetric flask. Dissolve in and dilute to volume with Eluent. Filter through a 0.45 µm syringe filter into a suitable autosampler vial, and seal (All components of the Standard Solution are available from Polymer Laboratories, Inc., Technical Center, Amherst Fields Research Park, 160 Old Farm Road, Amherst, MA 01002, USA). Column Equilibration After installation of a new column in the HPLC, pump Eluent through it overnight at 0.3 ml/min. Before calibration or analysis, increase the flow slowly to 0.8 ml/min over a 1-min period, then pump at 0.8 ml/min for at least 1 h before the first injection. Check the flow gravimetrically, and adjust it if necessary. Reduce the flow to 0.1 ml/min when the system is not in use. Data System Setup Set the integrator or computerized data handling system as their respective manuals instruct for normal gel permeation chromatographic determinations. Set the integration time to 15 min. Column Standardization After the HPLC system has been equilibrated at a flow rate of 0.8 ml/min for at least 1 h, inject 50 µl of the Standard Solution five times, allowing 15 min between injections. Record the retention times of the various components in the Standard Solution. Retention times for each component should agree within ± 2 sec. Insert the average retention time along with the molecular weight of each component into the calibration table of the molecular weight distribution software. System Suitability Check the regression results for a cubic fit of the calibration points. They should have an R 2 value of 0.9999+. Dextrose and stachyose should be baseline-resolved from one another and from the 5800 MW pullulan standard. Elevated valleys are usually observed between the 5800,

23,700 and 100,000 MW pullulan standards. Sample Preparation Transfer 50 mg of sample, accurately weighed, into a 10-ml volumetric flask. Dissolve in and dilute to volume with Eluent. Filter through a 0.45- µm syringe filter into a suitable autosampler vial. Inject 50 µl of the Sample Preparation, following the same conditions and procedure as described under Column Standardization. Using the Formula weight Distribution software of the data reduction system, generate a molecular weight distribution curve of the sample. There is no measurable peak above a molecular weight of 22,000. 5-Hydroxymethylfurfural (HMF) Principle HMF solutions absorb light in the ultraviolet region. The maximum absorption occurs at 283 nm and the molar extinction coefficient is 16,830 at that wavelength. The HMF concentration in polydextrose solutions is determined from the optical density at 283 nm and the application of the Beer-Lambert law. Apparatus - Standard laboratory equipment - Ultraviolet spectrophotometer - Spectrophotometer cells (quartz), 1.00 cm path length Accurately weigh 1.00±0.01 g of the sample into a 100-ml volumetric flask and make up to volume with distilled water (for polydextrose-n 70% solution use 1.43 ± 0.01 g sample). Read the optical density of this solution against a water blank at 283 nm in a 1.00 cm quartz cell in the spectrophotometer according to the directions supplied with the instrument. Under these conditions, the % HMF in the original sample is 0.0749 x optical density, on the dried basis. Calculation C = % HMF in the original polydextrose sample M = HMF molecular weight D = optical density of the solution L = the path length of the spectrophotometer cell E = the molar extinction coefficient for HMF The numbers 100 and 10 are factors to convert solution concentration in mg/l to % HMF in the original sample, on the dried basis. METHOD OF ASSAY Phenol Solution Add 20 ml of water to 80 g of phenol. Glucose Standard Solutions

Weigh accurately 100 mg of alpha-d-glucose (minimum 97% purity) into a 500-ml volumetric flask and make up to volume with distilled water. Dilute five aliquots of the solution with distilled water to obtain the following concentrations of standard: 50, 40, 20, 10 and 5 µg/ml. Standard Curve Run each analysis in triplicate. On a daily basis, pipet 2.0 ml of each of the Glucose Standard Solutions into 4-dram (14.8 ml) acetone-free screwcap vials. Add 0.12 ml of the phenol solution and mix gently. Uncap vials and add rapidly 5 ml of sulfuric acid TS. Immediately recap the vials and shake vigorously. CAUTION: Rubber gloves and safety shield should be used in the sulfuric acid addition step. Let the vials stand at room temperature for 45 min. Determine absorbances at 490 nm in a suitable spectrophotometer, using a Phenol Solution-sulfuric acid mixture as a blank in the reference cell. Plot mean absorbances versus concentrations in µg/ml. In triplicate, weigh accurately about 250 mg of the sample into a 250-ml volumetric flask and make up to volume with distilled water. Transfer a 10 ml aliquot to a 250-ml volumetric flask and make up to volume with distilled water. Proceed as in Standard Curve. Calculate the percentage of polymer by the formula: A = the sample absorbance S = the slope of absorbance versus glucose concentration in µg/ml obtained from the Standard Curve C = the concentration of the sample solution in µg/ml (adjusted for ash and moisture) P G and P 1 = the percentages of glucose and 1,6-anhydro-D-glucose, respectively, determined by the tests for monomers (see Purity tests for 1,6-Anhydro-D-glucose, glucose and sorbitol as described above).