UltiMetal Plus Advanced Chemistry for Stainless Steel Surface Deactivation

Similar documents
Agilent UltiMetal Plus Stainless Steel Deactivation for Tubing, Connectors, and Fittings

A New PEG GC Column with Improved Inertness Reliability and Column Lifetime Agilent J&W DB-WAX Ultra Inert Polyethylene Glycol Column

Analyze Hydrocarbon Impurities in 1,3-Butadiene with an Agilent J&W GS-Alumina PT Column

A Direct 5 ms Column Performance Comparison for Active Semi-Volatile Analytes

Quantification of Pesticides in Food without Calibration using GC/FID with the Polyarc Reactor

The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note

Highly Sensitive and Rugged GC/MS/MS Tool

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

Application Note. Abstract. Authors. Introduction. Food Safety

Analysis of USP Method <467> Residual Solvents on the Agilent 8890 GC System

Application Note. Abstract. Authors. Introduction

Understanding Gas Chromatography

Author. Abstract. Introduction

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Determination of Total Volatile Organic Compounds in Indoor Air Using Agilent 7667A mini TD and 7820A GC

Application Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors

Identifying Pesticides with Full Scan, SIM, µecd, and FPD from a Single Injection Application

The Analysis of Trace Contaminants in High Purity Ethylene and Propylene Using GC/MS. Application. Agilent Technologies/Wasson ECE Monomer Analyzer

Ultra-Inert chemistry for Trace Level Analysis

Evaluation of Capillary Columns for General Performance Parameters

Fast USEPA 8270 Semivolatiles Analysis Using the 6890/5973 inert GC/MSD with Performance Electronics Application

The end of. mass-speculation. MS Certified Vials Pre-cleaned and certified vials for mass spectrometry

Improved Volatiles Analysis Using Static Headspace, the Agilent 5977B GC/MSD, and a High-efficiency Source

Static Headspace Blood Alcohol Analysis with the G1888 Network Headspace Sampler Application

Introduction to Capillary GC

Direct Measurement of Metallic Impurities in 20% Ammonium Hydroxide by 7700s/7900 ICP-MS

CH 2252 Instrumental Methods of Analysis Unit V Gas Chromatography. M. Subramanian

Improved Peak Shape Performance and Consistency for Analysis of Challenging Polar Compounds

Enhanced Sensitivity for Biomarker Characterization in Petroleum Using Triple Quadrupole GC/MS and Backflushing

Gas Chromatography. Presented By Mr. Venkateswarlu Mpharm KTPC

Trajan SGE GC Columns

Sensitive Detection of 2-MIB and Geosmin in Drinking Water

CHAPTER 6 GAS CHROMATOGRAPHY

Chapter 27: Gas Chromatography. Principles Instrumentation Detectors Columns and Stationary Phases Applications

Application. Gas Chromatography February Introduction

The Suite for Environmental GC Analysis

Chemistry Instrumental Analysis Lecture 27. Chem 4631

Gas chromatography. Advantages of GC. Disadvantages of GC

Fast Analysis of USP 467 Residual Solvents using the Agilent 7890A GC and Low Thermal Mass (LTM) System

Signal, Noise, and Detection Limits in Mass Spectrometry

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY

Gas Chromatography. Introduction

Pesticides Analysis Using the Agilent 5977A Series GC/MSD

Semivolatile Organics Analysis Using an Agilent J&W HP-5ms Ultra Inert Capillary GC Column

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.

METHOD 8033 ACETONITRILE BY GAS CHROMATOGRAPHY WITH NITROGEN-PHOSPHORUS DETECTION

METHOD 3600C CLEANUP

Fast Analysis of Aromatic Solvent with 0.18 mm ID GC column. Application. Authors. Introduction. Abstract. Gas Chromatography

Industrial Applications with a New Polyethylene Glycol-Based GC Column

Introduction to Capillary GC. Page 1. Agilent Restricted February 2, 2011

Automated Sample Preparation of Headspace Standards Using the Agilent 7696 WorkBench

Improved GC/MS Analysis of Tomato Pesticides with Agilent Deactivated Silica Tubing

Simultaneous Compound Identification and Quantification with Parallel Polyarc /FID and MS

Application Note 032

Application Note. Author. Abstract. Introduction. Hydrocarbon Processing

Identification and Quantitation of PCB Aroclor Mixtures in a Single Run Using the Agilent 7000B Triple Quadrupole GC/MS

Improve Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application

Hints and Tips for APGC Coupled with Xevo TQ-S for Food and Environmental Analysis

Cerno Bioscience MassWorks: Acquiring Calibration Data on Agilent GC/MSDs

Techniques for the Analysis of Organic Chemicals by Inductively Coupled Plasma Mass Spectrometry (ICP-MS)

PAH Analyses with High Efficiency GC Columns: Column Selection and Best Practices

Application Note 116 Monitoring VOCs in Ambient Air Using Sorbent Tubes with Analysis by TD-GC/MS in Accordance with Chinese EPA Method HJ

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

Applying the Agilent 5977A MSD to the Analysis of USP<467> Residual Solvents with the 7697A Headspace Sampler and 7890B GC

Analysis of Natural Oils and Extracts Using the Low Thermal Mass LTM Series II System

2401 Gas (liquid) Chromatography

Challenging Pesticide Analysis Using an Agilent J&W DB-35ms Ultra Inert GC Column

Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 23: GAS CHROMATOGRAPHY

Agilent G2350A Atomic Emission Detector (AED)

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

Application. Gas Chromatography March 1998

SGE is excited to launch a new HPLC product line under the ProteCol brand.

Determination of trace elements in ultrapure semiconductor grade sulfuric acid using the Agilent 8900 ICP-QQQ in MS/MS mode

Chromatographic Methods of Analysis Section: 5 Gas Chromatography (GC) Prof. Tarek A. Fayed

Analysis of Ethanol and Isotopomers by 240 Quadrupole Ion Trap GC/MS

Comparing Collision/Reaction Cell Modes for the Measurement of Interfered Analytes in Complex Matrices using the Agilent 7700 Series ICP-MS

The 5975 inert MSD Benefits of Enhancements in Chemical Ionization Operation Technical Note

Determination of Volatile Aromatic Compounds in Soil by Manual SPME and Agilent 5975T LTM GC/MSD

Advantages of Reversed Sandwich Injection for Pesticide Residue Analysis

Supplementary Information

An Innovative Field-Based Analytical Method For Low-Level Detection of Chlorinated Solvents in Groundwater and Soil Samples

Activity in the FID Detection Port: A Big Problem if Underestimated

Determination of Off-Odor Compounds in Drinking Water Using an SPME Device with Gas Chromatography and Mass Spectrometry

Gas Chromatography (GC)! Environmental Organic Chemistry CEE-PUBH Analysis Topic 5

Chemistry Instrumental Analysis Lecture 28. Chem 4631

GC Resolution Do You See What I See?

High-Speed Environmental Analysis Using the Agilent 7500cx with Integrated Sample Introduction System Discrete Sampling (ISIS DS)

METHOD 8000A GAS CHROMATOGRAPHY

High Performance Liquid Chromatography

High Performance Liquid Chromatography

A faster, more accurate way of characterizing cube beamsplitters using the Agilent Cary 7000 Universal Measurement Spectrophotometer (UMS)

Introduction to Capillary GC

Ch24. Gas Chromatography (GC)

Screening of Pesticide Residues in Water by Sequential Stir Bar Sorptive Extraction-Thermal Desorption with GC/MS

Application Note. Authors. Abstract. Xin Sun Shandong Agriculture University, Taian, , China

Gas Chromatography. Vaporization of sample Gas-solid Physical absorption Gas-liquid Liquid immobilized on inert solid

Application Note # Performance of Method 8270 Using Hydrogen Carrier Gas on SCION Bruker SCION GC-MS

Understanding the Capillary GC Column: How to Choose the Correct Type and Dimension

Agilent 1260 Infinity Evaporative Light Scattering Detector (ELSD)

Exceptional Selectivity of Agilent ZORBAX Eclipse Plus Phenyl-Hexyl Columns to Separate Estrogens

Transcription:

UltiMetal Plus Advanced Chemistry for Stainless Steel Surface Deactivation Technical Overview Introduction Inert flow path technology Modern GC and GC/MS instrumentation is an important analytical tool in the accurate and reproducible measurement of many components at the low ppb level in a wide variety of matrixes. For accurate analyte measurement, compounds need to survive the journey from sample injection, vaporization in the inlet, separation on the column, and delivery to the detector. Many of the compounds of interest, in their passage from GC inlet to detector, can interact with exposed silanols and other chemically active sites present in the GC flow path. Most of the GC process takes place at elevated temperatures with increased reaction rates, which further raises the risk of compound degradation and adsorption phenomena. Example compound classes that are subject to increased reactive behavior include organic acids and bases, sulfur species, alcohols, amines, aldehydes, phenols, and pesticides.

Reducing the activity of GC flow path surfaces is, therefore, essential to minimize compound degradation, reduce peak tailing, achieve low level detection, and improve the accuracy of results for more reactive analytes. Two advanced chemistries, Ultra Inert and UltiMetal Plus, have been developed to curtail the activity of GC system surfaces as part of the Agilent Inert Flow Path solution. Ultra Inert deactivation chemistry is applied to critical parts in the GC system including Ultra Inert liners, Ultra Inert gold seals, and Ultra Inert GC columns. UltiMetal Plus technology is applied specifically to steel and stainless steel system parts such as unions, ferrules, tubing, backflush devices, the GC inlet weldment, and selected detector parts. Results and Discussion Inert flow path chemistries The objective of Ultra Inert and UltiMetal Plus deactivation chemistries is to improve the chemical inertness of surfaces inside the GC or GC/MS system that come into contact with compounds of interest. Agilent uses chemical vapor deposition (CVD) as the main chemical process to deposit the high-purity, high-performance, chemically inert layers UltiMetal Plus and Ultra Inert on key elements in the GC flow path. In a typical CVD process, the substrate is exposed to one or more volatile precursors that react or decompose, or both, through thermal energy on its surface to produce the desired deposit. The substrate does not react with the gases, but serves as a bottom layer. Depending on the process parameters: precursor(s), pressure, temperature, and time, the deposit layers differ in nature, density, and coverage. This deactivation process is extensively applied in the semiconductor industry to produce thin films on wafers. The effectiveness of a deactivation layer for chromatography purposes is highly dependent on the substrate or material on which it is applied. For this reason, Agilent has developed two complementing deactivation chemistries for its Inert Flow Path solution: UltiMetal Plus: a proprietary CVD process developed mainly for the deactivation of steel surfaces. UltiMetal deactivation chemistry was developed in the 198s and has a lower inertness profile than the Plus version. It is used exclusively in the manufacturing of UltiMetal-treated stainless steel capillary GC columns mainly for high temperature GC applications. UltiMetal is not applied to GC system parts in the Agilent Inert Flow Path solution. Figure 1 compares the surface inertness provided by the different surface treatments. Increased inertness Stainless steel Type 34/316 1% Surface inertness Stainless steel UltiMetal Stainless steel UM Plus Figure 1. Schematic representation of inertness difference between stainless steel, UltiMetal, and UltiMetal Plus. Analytical advantages of UltiMetal Plus Bare, untreated stainless steel has poor inertness characteristics, with metal oxides on the surface acting as catalysts to many reactions that include dehydration of alcohols, cracking of hydrocarbons, and esterification. The UltiMetal Plus layer covers most of these metal oxides and, thus, reduces the reactivity of the steel surface, lowering adsorption or catalytic breakdown of active compounds. The positive impact of the treatment at an analytical level is most noticeable for trace concentrations, with less peak tailing and improved linearity of response for many sensitive components. As compound adsorption and breakdown processes are minimized, the UltiMetal Plus treatment also improves the GC/MS system s detection limits. With the greater reliability of the generated data, the need to perform additional or duplicate analyses, in case of inconclusive results, is reduced. Ultra Inert: a deactivation based on a deposit through a proprietary CVD process for glass or fused-silica substrates (liners and GC columns), and gold layers (gold seals). 2

Features of UltiMetal Plus The most striking feature of parts treated with UltiMetal Plus is their rainbow appearance, from blue to silver metallic grey (Figure 2). Figure 2. Stainless steel components treated with UltiMetal Plus: GC inlet weldment, flexible metal ferrules, and FID jets. The color variation results from the light diffraction qualities of the layers and differences in UltiMetal layer thickness, which can vary between 7 and 1,Å. The roughness of the underlying stainless steel surfaces will also impact the final color appearance. The chromatographic performance benefits of improved analyte peak shape and reduced breakdown are independent of the UltiMetal Plus layer thickness and color. The UltiMetal Plus process ensures that all steel surfaces, corners, cavities, and interiors are uniformly treated. The maximum operating temperature of UltiMetal Plus parts is 4 C, compatible with the majority of GC applications. Tubing treated with UltiMetal Plus can be coiled to small diameters (2.5 cm Ø for 1/16 inch tubing) without detrimental effects on its deactivation properties. The surface of parts treated with UltiMetal Plus has hydrophobic properties (Figure 3). The formation of water droplets is used in QC procedures. Figure 3. Water droplet on an UltiMetal Plus-treated stainless steel surface. UltiMetal Plus performance assurance The manufacturing process and performance of components treated with UltiMetal Plus is monitored and assured through a number of QC test procedures: Layer thickness - The thickness of the layer is confirmed by spectral reflectance techniques that measure the amount of light reflected from a thin film over a range of wavelengths. Water droplet test - This QC test verifies the hydrophobicity of the UltiMetal Plus surface. Chromatographic QC test - This most challenging QC test measures the recovery of sensitive semivolatiles included in the EPA 827 method. Figure 4 illustrates the recovery of four compounds on two steel GC inlet liners (orange, green) treated with UltiMetal Plus in a split/splitless setup, compared to the recovery using a glass, Ultra Inert deactivated liner. The UltiMetal Plus treatment is judged successful and all steel parts in the same process batch are approved if the two UltiMetal Plus liners show recoveries over 6% for all four compounds, the pass/fail specification limit. Average recovery ratio (n=3), normalized to control UI liner 1.2 1.8.6.4.2 Aniline 2,4 DNP 4,6 DN2mP Benzidine Baseline (Ultra Inert Liner) UM + Liner 1 UM + Liner2 Specification Figure 4. Analyte recovery in a chromatographic QC test of UltiMetal performance. 3

Applications Steel items treated with UltiMetal Plus are applied in the Agilent Inert Flow Path solution for higher sensitivity, and improved accuracy and reproducibility of data. Figure 5 illustrates how UltiMetal Plus treatment of flexible metal ferrules in a GC/MS system back flush T-union dramatically improves recoveries of the polar pesticides acephate, omethoate, and demeton-s. A GC inlet/insert weldment and shell treated with UltiMetal Plus are integrated in the inert flow path model of the Agilent 789B GC. Figure 6 shows a comparison of the combined breakdown of DDT and endrin for Agilent and non-agilent GC flow paths. The Agilent Inert Flow Path solution, which includes an UltiMetal Plus-treated inlet weldment, clearly demonstrates the lowest breakdown level for DDT and endrin over 2 successive analyses. This provides improved reliability of results over prolonged periods, combined with lower replacement costs for key GC inlet consumables such as liners and gold seals. Counts Counts 1 4 2 1 1 4 2 1 Untreated FMF 5 ppb FMF + UltiMetal Plus 5 ppb Acephate Acephate Omethoate Omethoate Demeton-S Demeton-S 4.5 5. 5.5 6. Acquisition time (min) 6.5 7. 7.5 Figure 5. Effect of UltiMetal Plus on flexible metal ferrules in pesticide recovery (Agilent application note 5991-186EN). 35 3 % Combined breakdown 25 2 15 1 Non-Agilent flow path Agilent standard flow path Agilent Inert flow path Ultra Inert GC/MS column Ultra Inert gold seal Untra Inert liner UltiMetal inlet weldment and shell % Combined breakdown specification 5 5 1 Number of injections 15 2 Figure 6. DDT and endrin combined breakdown comparison for Agilent and non-agilent GC flow paths (Agilent application note 5991-1862EN). 4

Guidelines for use Many of the GC parts treated with UltiMetal Plus are generally not heavily exposed to a high degree of (matrix) contamination similar to GC columns, liners and gold seals. UltiMetal Plus parts more exposed to contamination would include the GC inlet weldment, Capillary Flow Technology devices, flexible metal ferrules, and FID jets. In case contamination is suspected and replacement is necessary, items should only be exchanged with genuine Agilent UltiMetal Plus-treated parts. UltiMetal Plus components can be cleaned only under strict conditions: Clean only with dichloromethane, acetone, or methanol Mild sonication can be applied to assist the removal of contaminants, but do not oversonicate as this can affect the deactivation properties of the surface layer Avoid the use of abrasive cleaner and (cotton) swabs Do not expose to temperatures > 4 C Avoid contact with basic solutions ph 8 that can accelerate deterioration of the layer References 1 P. Heijnsdijk Endrin and DDT Breakdown Evaluation Using an Agilent Inert Flow Path Solution Application note, Agilent Technologies, Inc. Publication number 5991-1862EN (213). 2. L. Zhao Evaluating Inert Flow Path Components and Entire Flow Path for GC/MS/MS Pesticide Analysis Application note, Agilent Technologies, Inc. Publication number 5991-186EN (213) 3. K. Lynam Agilent Inert Flow Path Enhancements Improve Drugs of Abuse Testing Application note, Agilent Technologies, Inc. Publication number 5991-1859EN (213). 4. K. Lynam Semivolatile Analysis Using an Inertness Performance Tested Agilent J&W DB-5ms Ultra Inert Column Application note, Agilent Technologies, Inc. Publication number 5989-8616EN (28). 5

www.agilent.com/chem Agilent shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. Information, descriptions, and specifications in this publication are subject to change without notice. Agilent Technologies, Inc., 214 Printed in the USA March 25, 214 5991-3357EN