PTA-427 BAROMETRIC PRESSURE TRANSDUCER OPERATOR S MANUAL

Similar documents
CR10TCR THERMOCOUPLE REFERENCE

3WHB10K 3-WIRE HALF BRIDGE TERMINAL INPUT MODULE INSTRUCTION MANUAL

CR10XTCR THERMOCOUPLE REFERENCE

MODEL 107 TEMPERATURE PROBE INSTRUCTION MANUAL

CR10XTCR THERMOCOUPLE REFERENCE

MODEL HMP45C TEMPERATURE AND RELATIVE HUMIDITY PROBE INSTRUCTION MANUAL

IRTS-P PRECISION INFRARED TEMPERATURE SENSOR INSTRUCTION MANUAL

INSTRUCTION MANUAL. CR10XTCR Thermocouple Reference. Revision: 1/03. Copyright (c) Campbell Scientific, Inc.

SP-LITE SILICON PYRANOMETER INSTRUCTION MANUAL

3WHB10K 3-Wire Half Bridge Terminal Input Module

MET ONE RAIN GAGE MODELS 380, 385, 380M, 385M

CVD20 20:1 Voltage Divider Revision: 5/12

NOVALYNX CORPORATION MODEL 110-WS-16BP BAROMETRIC PRESSURE SENSOR INSTRUCTION MANUAL

INSTRUCTION MANUAL. CS100 Barometric Pressure Sensor 3/05. Copyright (c) Campbell Scientific, Inc.

3WHB10K 3-Wire Half Bridge Terminal Input Module

CM3 PYRANOMETER INSTRUCTION MANUAL

WXT510 Weather Transmitter Revision: 4/07

WARRANTY AND ASSISTANCE

INSTRUCTION MANUAL. Model 207 Temperature and Relative Humidity Probe. Revision: 2/94. Copyright (c) Campbell Scientific, Inc.

INSTRUCTION MANUAL. SP Lite2 Pyranometer. August Copyright 2017 Campbell Scientific (Canada) Corp.

Model 108 Temperature Probe Revision: 4/07

INSTRUCTION MANUAL. CS500 Temperature and Relative Humidity Probe. Revision: 7/04. Copyright (c) Campbell Scientific, Inc.

INSTRUCTION MANUAL. CSI Model TB4 Rain Gage. Revision: 8/04. Copyright (c) Campbell Scientific, Inc.

INSTRUCTION MANUAL. LI200X-LC Pyranometer for MetData1 4/97. Copyright (c) Campbell Scientific, Inc.

TB-2012M BAROMETRIC PRESSURE SENSOR USER S MANUAL

INSTRUCTION MANUAL. CS547 Conductivity and Temperature Probe and A547 Interface. Revision: 9/00. Copyright (c) Campbell Scientific, Inc.

Model ASPTC Aspirated Shield with Fine Wire Thermocouple

227 Delmhorst Cylindrical Soil Moisture Block Revision: 5/13

User s Manual: MODEL 904-T CLINOMETER PAK

CS100 Barometric Pressure Sensor

Eppley PIR Precision Infrared Radiometer

Field Pro Operation and Installation Manual

Low Pressure Sensor Amplified Analog Output SM6295-BCM-S

Small, Gauge Pressure Sensor

Small Absolute Pressure Sensor

Model HFP01 Soil Heat Flux Plate Revision: 7/12

Medium Pressure Sensor Analog Output

INSTRUCTION MANUAL. Laser Diode Sarcomere Length. Aurora Scientific Inc. 360 Industrial Parkway South, Unit 4 Aurora, Ontario, Canada L4G 3V7

Small Gage Pressure Sensor

LUDLUM MODEL 42-5 NEUTRON BALL CART. August 2015 Serial Number PR and Succeeding Serial Numbers

MKIII -MB USER S GUIDE 09/18/18. Rev. 3

OEM Silicon Pressure Die

SM98A Harsh Media Backside Absolute Pressure Series

Ambient Weather DHR70B-BRASS Handheld Fishing Barometer User Manual

QUICK SET UP MANUAL WEATHER CENTER

Ambient Weather WS-228TBH 9" Brushed Aluminum Traditional Barometer with Temperature and Humidity, Radiant Blue User Manual

Fischer Instruments Chrome and Black Wood Base Weather Station with Barometer, Hygrometer, Thermometer and Quartz Clock User Manual

Fischer 1508BTH-45 5" Brass Barometer with Temperature & Humidity User Manual

Pressure Display Controller

Ambient Weather WS-152B 6" Contemporary Barometer User Manual

Mini Environmental Quality Meter

Fischer Banjo Weather Station with Thermometer, Hygrometer, Barometer User Manual

IntraSense TM Series 1-French Wire-Connected Pressure Sensor SMI-1A AAUU

STATIC GAS MONITOR Type SGM/DEW Revision A of 20 aprile 2016

User s Guide. Waterproof Palm ph Meter Model PH220. Introduction

Fischer Instruments Stainless Steel Barometer User Manual

HFM-6 and HFM-7 OPERATOR S MANUAL

473 Dew Point Hygrometer

QUANTUM CONCEPT. Swimming User s Manual

CAUTION: BEFORE YOU BEGIN, ALWAYS MAKE SURE THE WEAPON IS UNLOADED AND SAFE TO HANDLE.

Route and retain the clinometer cable so that it does not interfere with moving parts where the unit is mounted.

WARRANTY AND ASSISTANCE

FIELD GUIDE FOR HORUS SCOPES

VIBRATION METER. Instruction Manual.

Ambient Weather WS-GL026 Porthole Collection Weather Center with Thermometer, Hygrometer, Barometer User Manual

SkyScan EWS-PRO - Manual -

e/m APPARATUS Instruction Manual and Experiment Guide for the PASCO scientific Model SE D 5/ PASCO scientific $5.

473 Dew Point Hygrometer

Hadrons Desktop U.S. Atomic Clock & Weather Station

INSTRUCTION MANUAL FOR MM10 Relay

WS-7211U Wireless 433 MHz Weather Station. Instruction Manual

Today s Weather 24 Hour Forecaster

IRTS-P Precision Infrared Temperature Sensor

HFM-6, HFM-7, & HFM-8 OPERATOR S MANUAL

NOVALYNX CORPORATION ELEVATION CORRECTION TABLES FOR BAROMETRIC PRESSURE SENSORS

Melton Series. Owners Manual. Lab Centrifuge. Model # s A C, A C, B C, B C, C C, C C, D C, D C

Field IT 50T Series Transmitters

BB1 & BB2 INSTALLATION & MAINTENANCE INSTRUCTIONS

TEMPERATURE COMPENSATION FOR MEAS PRESSURE SENSORS APPLICATION NOTE

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

iweathar EDGE V Installation Guide Copyright 2012 iweathar. All rights reserved.

THM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist

WT-3131A Radio-controlled Analog Clock With Weather Forecast. Instruction Manual

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

INSTRUCTION MANUAL ANALOG COLORIMETER

Franck-Hertz Experiment

Installation Manual. Models 4911A/4911. VW Rebar Strain Meters

WEATHER STATION FOR SOLAR FARM MONITORING

CHROMA Colorimeter Model 252

HCL Series Miniature compensated low pressure sensors

technical bulletin Installation Instructions: Wall-Mount Dewpoint Probe ( )

O P E R A T I N G M A N U A L

473-SHX Dew Point Mirror

792A AC/DC Transfer Standard

792A AC/DC Transfer Standard

INSTRUCTION MANUAL. Model HFP01SC Self-Calibrating Soil Heat Flux Plate Revision: 3/14. Copyright Campbell Scientific, Inc.

Temperature Compensation for MEAS Pressure Sensors

Operating Instructions for Digital Manometer. Model: MAN-SD

ED 701 General Industry Pressure Transmitter

Instruction Manual. DTP Series DC Termination Panels

Transcription:

PTA-427 BAROMETRIC PRESSURE TRANSDUCER OPERATOR S MANUAL REVISION: 4/95 COPYRIGHT 1991, 1995 CAMPBELL SCIENTIFIC, INC.

WARRANTY AND ASSISTANCE The PTA-427 Barometric Pressure Transducer is warranted by CAMPBELL SCIENTIFIC, INC. to be free from defects in materials and workmanship under normal use and service for twelve (12) months from date of shipment unless specified otherwise. Batteries have no warranty. CAMPBELL SCIENTIFIC, INC.'s obligation under this warranty is limited to repairing or replacing (at CAMPBELL SCIENTIFIC, INC.'s option) defective products. The customer shall assume all costs of removing, reinstalling, and shipping defective products to CAMPBELL SCIENTIFIC, INC. CAMPBELL SCIENTIFIC, INC. will return such products by surface carrier prepaid. This warranty shall not apply to any CAMPBELL SCIENTIFIC, INC. products which have been subjected to modification, misuse, neglect, accidents of nature, or shipping damage. This warranty is in lieu of all other warranties, expressed or implied, including warranties of merchantability or fitness for a particular purpose. CAMPBELL SCIENTIFIC, INC. is not liable for special, indirect, incidental, or consequential damages. Products may not be returned without prior authorization. To obtain a Returned Materials Authorization (RMA), contact CAMPBELL SCIENTIFIC, INC., phone (435) 753-2342. After an applications engineer determines the nature of the problem, an RMA number will be issued. Please write this number clearly on the outside of the shipping container. CAMPBELL SCIENTIFIC's shipping address is: CAMPBELL SCIENTIFIC, INC. RMA# 815 West 1800 North Logan, Utah 84321-1784 CAMPBELL SCIENTIFIC, INC. does not accept collect calls. Non-warranty products returned for repair should be accompanied by a purchase order to cover the repair. 815 W. 1800 N. Logan, UT 84321-1784 USA Phone (435) 753-2342 FAX (435) 750-9540 www.campbellsci.com Campbell Scientific Canada Corp. 11564-149th Street Edmonton, Alberta T5M 1W7 CANADA Phone (780) 454-2505 FAX (780) 454-2655 Campbell Scientific Ltd. Campbell Park 80 Hathern Road Shepshed, Loughborough LE12 9GX, U.K. Phone +44 (0) 1509 601141 FAX +44 (0) 1509 601091

MODEL PTA-427 BAROMETRIC PRESSURE TRANSDUCER 1. GENERAL The PTA-427 Barometric Pressure Sensor is designed to be installed in the same enclosure that the datalogger is housed. The enclosure must be vented to the atmosphere and kept stocked with active desiccant. A two foot power switching cable is provided to connect the sensor to the datalogger. If the PTA-427 is going to be housed outside of the datalogger enclosure, a longer cable must be ordered. The PTA-427 sensor outputs a 0-5 VDC signal for use with the 21X and CR7. For use with the CR10, a 2 to 1 voltage divider is incorporated into the power switching cable. The voltage divider converts the output from the sensor to 0-2.5 volts. The PTA-427 uses Vaisala's patented silicon capacitive pressure sensor. A linear output of 0-5 VDC is proportional to 800-1060 millibars (other ranges optional). The transmitter is temperature compensated over an operating range of -40 C to +60 C. The PTA-427 requires 11-30 VDC and a three second warmup time. 2. PTA-427 SPECIFICATIONS The following pressure transmitter specifications were provided by Vaisala, Inc.: TABLE 1. PTA-427 Specifications OPERATING RANGE Pressure Range (1 mb = 1 hpa) PTA-427 800 to 1060 mb PTA-427A 600 to 1060 mb Temperature Range -40 C to +60 C Humidity Range non-condensing ACCURACY PTA-427 Linearity * ±0.3 mb Hysteresis * Repeatability * Calibration uncertainty ** ±0.2 mb Accuracy @ 20 C *** ±0.4 mb PTA-427A Linearity * Hysteresis * Repeatability * Calibration uncertainty** Accuracy @ 20 C *** ±0.6 mb ±0.2 mb ±0.6 mb * Defined as ±2 standard deviation limits of end-point non-linearity, pressure hysteresis error and pressure repeatability error. ** Defined as ±2 standard deviation limits of inaccuracy of the primary and working standards in reference to international standards. *** Defined as the root sum of the squares of end-point non-linearity, hysteresis error, repeatability error, and calibration uncertainty at room temperature. Temperature dependence at 1000 mb ±0.02 mb/ C at 800 mb ±0.08 mb/ C at 600 mb ±0.12 mb/ C Stability systematic offset drift ±0.2 mb/year effect of thermal and mechanical shocks less than ±0.3 mb GENERAL Supply voltage 11 to 30 VDC Supply voltage sensitivity less than 0.1 mb Current consumption 7 ma typical Output voltage 0 to 5 VDC Load resistance 10 kohm minimum Settling time 2 seconds to reach full accuracy after power on Warm-up shift less than 0.1 mb Acceleration sensitivity less than ±0.05 mb/g Housing material aluminum Pressure fitting barbed fitting for 1/8" I.D. tubing Overpressure limit 2000 mb Electrical connector screw terminals Weight 160 g Dimensions: 128 mm x 69 mm x 31 mm (5.0 in. x 2.7 in. x 1.2 in.) 1

MODEL PTA-427 BAROMETRIC PRESSURE TRANSDUCER 3. WIRING WHITE is not used on the 21X or the CR7 installation; it should be taped or cut to protect from shorting. FIGURE 3-1. Wiring for the PTA-427 4. DATALOGGER PROGRAMMING Instruction 4 is used to measure the PTA-427 barometric pressure transmitter. Instruction 4 excites the switching circuit which provides 12 VDC power to the sensor. The instruction delays three seconds after power-up and then makes a single-ended measurement of the output signal. Sample program for a 21X or CR7: 01: P4 Excite-Del-SE 01: 1 Rep 02: 5 5000 mv slow range 03: 1* In Channel 04: 1* Excit all reps w/exchan1 05: 300 Delay (units = 0.01 Sec.) 06: 5000 Excit mvolts 07: 1* Loc[:Press mbar] 08: 0.052 Mult (Range in mbar / Output) 09: 800 Offset (Low Range of PTA-427) * Proper entries will vary depending on the program and datalogger channel usage. Sample program for the CR10: 01: P4 Excit-Del-SE 01: 1 Rep 02: 5 2500 mv slow range 03: 1* In Channel 04: 1* Excit all reps w/exchan1 05: 300 Delay (units = 0.01 Sec.) 06: 2500 Excit mvolts 07: 1* Loc[:Press mbar] 08: 0.104 Mult (Range in mbar / Output) 09: 800 Offset (Low Range of PTA-427) * Proper entries will vary depending on program and datalogger channel usage. 5. MULTIPLIER AND OFFSET CALCU- LATIONS Output from the PTA-427 is 0-5 VDC, which corresponds to 800-1060 millibars (other ranges optional). The multiplier and offset used to convert the voltage measurements to millibars of pressure are: 2

MODEL PTA-427 BAROMETRIC PRESSURE TRANSDUCER Multiplier = Pressure range/output voltage range = 1060 mbar - 800 mb 5000 mv - 0 mv = 260 mb / 5000 mvolts = 0.052 The offset of the PTA-427 sensor is equal to the lower limit of the sensor range (i.e., the sensor range is 800 to 1060 mb, the offset is 800 mb). The measurement result using a multiplier of 0.052 and an offset of 800 is true barometric pressure in millibars. The weather service and most airports, radio stations and TV stations correct the pressure recorded at a particular station to what it would be if the station was located at sea level. This is done so that weather forecasters can obtain a clearer picture of what is happening as a storm crosses over mountains or high plateaus. The following equation is used to determine the pressure correction factor, which is added to the 800 mbar offset in Instruction 4 to have the datalogger output barometric pressure corrected to sea level. Because barometric pressure is strongly affected by elevation, the elevation of the site should be as accurate as possible. CR10 example with pressure correction factor: 01: P4 Excit-Del-SE 01: 1 Rep 02: 5 2500 mv slow range 03: 1* In Channel 04: 1* Excit all reps w/exchan1 05: 300 Delay (units = 0.01 Sec.) 06: 2500 Excit mvolts 07: 1* Loc[:Press mbar] 08: 0.104 Mult (Range in mbar / Output) 09: 952.68 Offset CONVERSION FACTORS mbar * 0.0145 = PSI mbar * 0.75006 = mm of Hg mbar * 0.02953 = in. of Hg mbar * 0.00102 = kg/cm 2 mbar * 0.1 = kpa REFERENCES Wallace, J.M., and Hobbes, P.V., Atmospheric Science an Introductory Survey, Academic Press, New York, N.Y., 1977, pp. 59-61. P=1013.25[1-(1-E/44307.69231) 5.25328 ] where E is the elevation in meters above sea level. For example, the correction factor (P) for Logan, Utah, at 4450 Ft elevation is: 4450 ft * m/3.281 ft = 1356.29m Pressure correction factor (P) = 152.68 mbar Transducer offset = 800.00 mbar Pressure correction factor (P) = 152.68 mbar Offset for sea level correction = 952.68 3