HFM 100 Series. Thermal Conductivity Meter for measurement of insulation and construction materials.

Similar documents
LaserComp, Inc., DESCRIPTION OF THE INSTRUMENT

Vincent Barraud SOPREMA BASICS OF THERMAL INSULATION

The Characterization of Thermal Interface Materials using Thermal Conductivity for Within Sample and Batch to Batch Variation Analysis

Standard Test Method for Determination of the Thermal Conductivity of Anode Carbons by the Guarded Heat Flow Meter Technique 1

473 Dew Point Hygrometer

REPORT NUMBER: MID-001 ORIGINAL ISSUE DATE: April 22, 2016 REVISED DATE: NA. EVALUATION CENTER Intertek 8431 Murphy Drive Middleton, WI 53562

SurPASS. Electrokinetic Analyzer for Solid Samples. ::: Innovation in Materials Science

Sensing, Computing, Actuating

novaa 800 D Atomic Absorption Spectrometer

Thermal Interface Material Performance Measurement

473 Dew Point Hygrometer

473-SHX Dew Point Mirror

Sensors and Actuators Sensors Physics

Corrections for Thermal Expansion in Thermal Conductivity Measurement of Insulations Using the High-Temperature Guarded Hot-Plate Method

FORCE TENSIOMETER K100 THE HIGH-END SOLUTION FOR MEASURING SURFACE AND INTERFACIAL TENSION

ASTM C STEADY-STATE HEAT FLUX MEASUREMENTS AND THERMAL TRANSMISSION PROPERTIES BY MEANS OF THE HEAT FLOW METER APPARATUS

Standard Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded-Hot-Plate Apparatus 1

Your partner in Science!

Temperature control for Varian Cary line of UV/Vis Spectrophotometers and the Eclipse Fluorometer

Humidity Calibration Solutions

TE 75R RESEARCH RUBBER FRICTION TEST MACHINE

Coordinate Measuring Machines Coordinate INDEX Measuring Machines Coordinate Measuring Machines New Products

We are IntechOpen, the first native scientific publisher of Open Access books. International authors and editors. Our authors are among the TOP 1%

THERMOCOUPLE CHARACTERISTICS TRAINER

ECS8020 ORGANIC ELEMENTAL ANALYZER CHNS-O Analyzer

Modified Transient Plane Source (MTPS): Theory of Operation

Determination of installed thermal resistance into a roof of TRISO-SUPER 12 BOOST R

TESTING THERMOELECTRIC GENERATORS. Introduction. Test Considerations. Application Note n by Thermoelectric Conversion Systems Limited (TCS)

Humidity Calibration Solutions

Standard Test Method for Evaluating the Resistance to Thermal Transmission of Materials by the Guarded Heat Flow Meter Technique 1

IN-PLANE THERMAL CONDUCTIVITY OF FLAT PLATES UTILIZING THE FOURIER HEAT CONDUCTION LAW

Bilateral National Metrology Institute Comparison of Guarded-Hot-Plate Apparatus

Thermal Cube. Custom-built Heat Flux Sensor

Effective Thermal Conductivity of High Temperature Insulations for Reusable Launch Vehicles

ROTANTA 460/460 R Benchtop, Underbench and Floorstanding Centrifuges classic/cooled

Thermal Resistance Measurement

TeraLED. Thermal and Radiometric Characterization of LEDs. Technical Specification.

Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS)

integrating-sphere-construction-kits

Thermal Cube. Custom-built Heat Flux Sensor

i.mx 6 Temperature Sensor Module

TRIDENT. Thermal Conductivity (k) 1 instrument, 3 methods for. Conforms to ASTM D7984, D5334, D5930 and ISO (It s better to have options.

fdfdfdfdfd Effects of Interface Resistance on Measurements of Thermal Conductivity of Composites and Polymers

Measurements & Instrumentation. Module 3: Temperature Sensors

Determining of Thermal Conductivity Coefficient of Pressed Straw (Name of test)

Akhan Tleoubaev Andrzej Brzezinski

The Elzone II Particle Count and Size Analyzer

2. THERMAL DIFFUSIVITY SYSTEM (TDS)

Particle Analysis at the Touch of a Button. Litesizer series

FORCE TENSIOMETER K100 THE HIGH-END SOLUTION FOR MEASURING SURFACE AND INTERFACIAL TENSION

Temperature Measurement

Phone (1) ; Fax (1) ;

NEW! PCR next to me. Eppendorf Mastercycler nexus: combine, connect, control

Assessing The Thermal Performance of Building Enclosure Materials Using A Medium-Size Hot Box Chamber Summer Meeting Torkan Fazli

CHAPTER 5 CONVECTIVE HEAT TRANSFER COEFFICIENT

Uncertainty Workshop: Overview of uncertainty factors in HTGHPs

TEST METHOD FOR MEASURING INSULATION VALUES OF CRYOGENIC PIPES

Skin Damage Visualizer TiVi60 User Manual

THE ACOUSTIC IMPEDANCE MEASUREMNET SYSTEM USING TWO MICROPHONES

THERMAL CONDUCTIVITY OF BUILDING MATERIALS: AN OVERVIEW OF ITS DETERMINATION

Determination of thermal transmittance of window (test title)

Temperature Measurement and First-Order Dynamic Response *

High Pressure DSC Differential Scanning Calorimeter

1 One-Dimensional, Steady-State Conduction

Therm (TC30. Solid, Versatile for. Liquid. & Paste. Little. Range. Wide.

Use of Phase-Change Materials to Enhance the Thermal Performance of Building Insulations

Standard Test Method for Measuring the Steady-State Thermal Transmittance of Fenestration Systems Using Hot Box Methods 1

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

Defining quality standards for the analysis of solid samples

THE MEASUREMENT OF SOLAR ULTRAVIOLET SPECTRAL IRRADIANCE PROBLEMS & SOLUTIONS

Reliable Test Results

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

DEVELOPMENT OF THE MEASURING SYSTEM FOR ANALYSING THE THERMAL PROPERTIES OF CLOTHING

15. Compare the result with the value you have taken above Compare the calculated pressure value with the actual pressure value that you have

Senior Design Group May14-03

Agilent Cary 630 FTIR sample interfaces combining high performance and versatility

Introduction to Blackbody Sources

881 Compact IC pro / 882 Compact IC plus for ion chromatography. Intelligent. Reliable. Precise.

A. Solar Walls. B. Prototype I

C-Therm TCi Principles of Operation Introduction

Analog Technologies. ATEC1 49 Circular TEC Modules

5.5. Calibration and Test Procedures

Strain Measurement Techniques for Composite Coupon Testing

The solution for all of your

Overview Brochure Comprehensive range of instrumentation for the measurement of moisture and oxygen

Understanding uncertainties associated with the 5128A RHapid-Cal Humidity Generator

The Fundamentals of Moisture Calibration

Temperature Measurement

Dr. Michael Müller. Thermal Management for LED applications

Microscopy Cryostat System

costech instruments ECS 4010 Elemental Combustion System CHNS-O

Finite Element Modules for Enhancing Undergraduate Transport Courses: Application to Fuel Cell Fundamentals

Air velocity & IAQ measuring instruments

ISEmax CAM40/CAS40. Technical Information

AGING OF THERMAL INSULATION MATERIALS BY ACCELERATED LABORATORY TEST METODS

ALPHA. Innovation with Integrity. The very compact and smart FTIR spectrometer FTIR

NFRC THERMAL TEST SUMMARY REPORT January 27, 1999 Test Specimen

QuantumMCA QuantumNaI QuantumGe QuantumGold

MEASUREMENT OF THE THERMAL DIFFUSIVITY OF BUILDING MATERIALS

Effusivity is defined as the square root of the product of thermal conductivity, k, density,

Transcription:

HFM 100 Series Conforms to International Standards ASTM C518, ISO 8301, and EN 12667 Thermal Conductivity Meter for measurement of insulation and construction materials.

Hot Disk TPS -160 to 1000 C HFM THW -20 to 70 C -50 to 400 C TLS -40 to 100 C 0.001 0.01 0.1 1.0 10.0 100.0 1000.0 10000.0 Thermal Conductivity [ W/(m K)] LABORATORY INSTRUMENTS PORTABLE METERS Thermtest has been advancing the measurement of thermal conductivity, thermal diffusivity, and specific heat for more than a decade. With more than 1500 satisfied customers, our unique combination of advanced thermal conductivity instrumentation for the laboratory, portable meters for the field, and accessories, enables us to provide ideal solutions to fit any material testing application and budget. Our proud commitment to being a leader in thermal conductivity has fueled our success through rigorous development and key partnerships, creating a lineup of industry leading testing solutions for the laboratory, field, and production-line. info@thermtest.com Toll free: 1-866-249-0077 International: 1-506-458-5350

100 SERIES HEAT FLOW METER The Heat Flow Meter (HFM) 100 is an easy-to-use rapid technique for the measurement of thermal resistance and thermal conductivity of insulation products, construction materials, packaging, and assemblies. Thermal conductivity is a measure of the ability of a material to conduct heat and can be critical for defining energy efficiency and thermal performance in materials. The Thermtest HFM has been designed and engineered to combine the highest accuracy, repeatability, widest temperature range, and industry leading performance, all at an exceptional value.

INTRODUCTION HFM 100 SERIES FEATURES Robust Design Integrated On-Board Control Four Optical Encoders Extended Thermal Conductivity Thermocouple Upgrade Four Stepper Motors Peltier Element Upper Plate (T u ) Upper Transducer(Q u ) Sample Lower Plate (T L ) Peltier Element Lower Transducer (Q L )

FEATURED HEAT FLOW METER CAPABILITIES The cost effective HFM 100 instrument is an excellent choice when making steady-state thermal conductivity measurements of specimens such as insulation products and construction materials. Thermtest has rigorously engineered the heat flow meter (HFM) to meet the requirements of international standards including ASTM C518, ISO 8301, and EN 12667. Operating the HFM is straightforward a sample is positioned between two heating - cooling plates, and the upper plate, powered by stepper motors positioned in each corner, lowers to contact the top of the sample. Plate contact with the test specimen is controlled by a standard applied pressure, or by a user defined specimen thickness. Stepper motors are controlled by individual optical encoders for measurement of sample thickness (L), to the nearest 0.1 mm (0.004 in). Integrated logic between stepper motors allows the upper plate to sense and adjust for specimens with surface variations, optimizing plate - specimen contact for measurements. One heat flux sensor is integrated into each plate, and is used to monitor heat flux (Q/A), generated due to the difference in temperature (ΔT) between the top and bottom plate at regular intervals, until steady-state heat flux is observed. The composite heat flux is then used to measure thermal resistance (R) and calculate thermal conductivity (λ) according to Fourier s Law. Two flux sensors for accurate measurement of thermal resistance and thermal conductivity Peltier heating / cooling plates for rapid control of temperature Thickness is measured to an accuracy of 0.1 mm (0.004 in) with the use of four digital optical encoders Front panel operation allows full control of all HFM functions, or use the intuitive HFM Software for basic and additional functions, such as printing and exporting Plate clamping can be automated or set to a user defined thickness ideal for compressible materials λ = Q L R = L A ΔT λ UNITS UNITS W/m K or BTU/(hr ft F) m 2 K/W or hr ft 2 F/BTU Follows international standards: ASTM C518, ISO 8301, and EN 12667 3

SPECIFICATIONS HFM 100 SPECIFICATIONS Following international standards, the HFM 100 is designed for testing both homogeneous and heterogeneous materials. The HFM 100 sample size allows for representative testing of materials typically found in insulation and construction industries. Materials Insulation, Solids, and Textiles Type of Sensors Flux Sensors (x 2) Applications Direction Thermal Conductivity Range High Thermal Conductivity Kit General Testing Through-Thickness 0.005 to 0.5 W/m K (0.035 to 3.5 BTU/(hr ft F)) Up to 2.5 W/m K (17.3 BTU/(hr ft F)) Measurement Time 30 to 60 min Reproducibility Typically better than 1% Accuracy Typically better than 3% Plate Temperature Range* Maximum Sample Size -20 to 70 C (-4 to 158 F) Up to 300 x 300 x 100 mm (12 x 12 x 4 in) Standard ASTM C518, ISO 8301, and EN 12667 4 Method is continually improved; specifications are subject to change without prior notice. *Requires chilled circulator. TRUSTED ACCURACY AT AN AFFORDABLE PRICE

HFM 100 HIGHLIGHTS ACCURATE MEASUREMENTS TEMPERATURE CONTROL THICKNESS MEASUREMENT HEAT FLUX SENSORS RESOLUTION < 0.1 C (0.18 F) ACCURACY < 0.1 mm (0.004 in) VERSATILE OPERATION CLAMPING CONTROL REFERENCE MATERIALS OR STAND-ALONE OR SOFTWARE AUTOMATED OR MANUAL CERTIFIED OR CUSTOM 5

vv CHARACTERISTICS MEASUREMENT OF HEAT FLUX A heat flux sensor is a thermopile sensor, consisting of thermocouple junctions arranged uniformly across the sensor surface. Each individual junction generates an T1 T2 electrical voltage, proportional to the difference in temperature across the hot and cold junctions of the thermocouple. For accurate measurements of heat flux, one sensor is integrated into the surface of each testing plate of the HFM. This intimate contact reduces the level of calibration required, resulting in improved test results. TEMPERATURE CONTROL Thermoelectric Peltier elements are used to heat and cool the HFM testing plates. A thermoelectric element is a solid-state active heat pump which transfers heat from one side of the device to the other, with consumption of electrical energy, depending on the direction of the current. This flexibility allows the user to easily change heating and cooling direction, to best match their testing application, at a temperature resolution of < 0.1 C (0.18 F). Each thermoelectric module is matched with a thermocouple and smart temperature control to optimize the speed and accuracy of the plate temperatures. 6

THICKNESS MEASUREMENT Accurate sample thickness is optimal for determining thermal resistance of a material with the measurement of thermal conductivity. The HFM 100 system features the advantage of either an automatic determination of sample thickness, for rigid materials, or a user defined sample thickness, for compressible materials. Sample thickness is measured using digital optical encoder technology. Four encoders are positioned at each corner of the top sample plate. Multiposition encoder placement ensures the most accurate (< 0.1 mm / 0.004 in) measurement of sample thickness, and in the end, thermal resistance for materials being measured. VERSATILE OPERATION The HFM 100 offers users two versatile and convenient methods of operation run your measurements independently using the integrated front control panel, or by using the intuitive Windows based HFM software included with each system. The simple to use software offers additional features over the front panel operation, including unlimited steps of temperature automation when testing, and additional functions like saving, exporting, and printing measurement results. With front panel control, users can automate up to five steps of temperature when making measurements, or unlimited steps with the HFM software. HFM results are conveniently available in both SI and Imperial Units of measure. 7

CHARACTERISTICS CLAMPING CONTROL For rigid materials, plates automatically clamp together for optimum contact between sample and heat flux sensors. For compressible materials, the desired height of the sample may be entered manually and the plate will automatically stop at the entered sample height. REFERENCE MATERIALS Every HFM 100 system comes complete with one Standard Reference Material (SRM) of your choosing, available from the National Institute of Standards and Technology (NIST). SRM 1450d - Fibrous Glass-Board is certified for thermal conductivity from 6.85 to 66.85 C (44.33 to 152.33 F) and is available in a thickness of 25 mm (1 in). SRM 1453 - Expanded Polystyrene Board is certified for thermal conductivity from 7.85 to 39.85 C (46.13 to 103.73 F), and is available in a thickness of 12.5 mm (0.5 in). In addition to NIST Standard Reference Materials, Thermal Transfer Standards (TS) can be developed by Thermtest, for specialized testing applications. 8

ACCURACY & REPEATABILITY A sample of NIST SRM 1450d was repeatedly tested to confirm the accuracy and repeatability of the HFM 100. Prior to each of the 20 measurements, the NIST 1450d sample was removed, and then placed back within the HFM 100 chamber. The certified thermal conductivity for the NIST piece at 20 C (68 F) is 0.03239 W/m K (0.2246 BTU/(hr ft F)). The average thermal conductivity value received from all 20 tests was 0.0325 W/m K (0.2253 BTU/(hr ft F)). All tests had a repeatability within 0.5%, and an accuracy within 1% of the certified value. 9

MEASUREMENT SAMPLE MEASUREMENT 1 THE SAMPLE The sample should be between 150 mm and 300 mm square (6 in to 12 in square), and have parallel surfaces. Sample height is automatically measured by the HFM 100; however for compressible materials, desired sample thickness can be manually entered for predetermined testing thickness. 1 min. 2 Place the sample between the HFM 100's parallel testing plates. INSERT SAMPLE For smaller samples or samples of differing shapes from the testing chamber, place the sample within the center of the lower plate, positioned directly over the heat flux sensor. 1 min. 10

3 4 EFFICIENCY WITH EASE CLOSE PLATES The top plate automatically lowers for rigid samples or to a predetermined thickness for compressible samples. A single mean temperature or steps of temperature may be selected for an automated testing routine. Testing can be performed in either quality control or high accuracy (30 to 60 min) modes for test times which best fit your application. Once testing is complete, results can be saved, printed, or exported to Microsoft Excel for further processing. For added accuracy when testing rigid samples, the top plate makes a short confirming movement for optimum contact and measurement of thickness. Additionally, this short movement will also compensate for any issue with sample flatness. RUN EXPERIMENT 1 min. 30-60 min. 11

APPLICATIONS HFM 100 APPLICATIONS INSULATION VS. TEMPERATURE The Thermtest HFM 100 is capable of testing materials over a temperature range of -20 to 70 C (-4 to 158 F). NIST 1450d, Fibrous Glass Board, is a certified Standard Reference Material from the National Institute of Standards and Technology. Measured results are within 3% of the certified values. HIGH THERMAL CONDUCTIVITY KIT With the added High Thermal Conductivity Kit, the HFM-100 is able to accurately, and efficiently measure higher thermal conductivity materials, such as glass and ceramics. For such applications, an external thermocouple kit is used in combination with the sample being tested. Macor, Quartz, and Pyrex were tested in the HFM from 10 C to 60 C (50 F to 140 F). All measured values are within the stated accuracy of the system, +/- 5%. 12

BATTING INSULATION When testing compressible materials, such as batting insulation, slight changes to the density of a material, due to compressive forces, may alter thermal conductivity. Both a fiberglass and a stone wool batting insulation were tested with the HFM. A thermal conductivity of 0.0430 W/m K (0.2981 BTU/(hr ft F)) was the result of the fiberglass testing, where 0.0364 W/m K (0.2524 BTU/(hr ft F)) was the result of the stone wool insulation test. These values were within 3% of the stated manufacturers thermal conductivity. AEROGEL BLANKETS Aerogel has one of the lowest thermal conductivities known to solids. An aerogel blanket of choice was selected to test by the Heat Flow Meter. Results concluded a thermal conductivity of 0.024 W/m K (0.1664 BTU/(hr ft F)), which is within 3% to the manufacturers specification. WOOD As wood is rigid, the HFM can be set to automatically adjust to the height of the sample. Testing of this softwood produced a thermal conductivity reading of 0.12 W/m K (0.8320 BTU/(hr ft F)), an exact match to the literature values for softwoods. 13

METHODS Methods Comparison HFM TPS THW TLS Accuracy ± 3% ± 5% ± 5% ± 5% Measured Property Thermal Resistance, Thermal Conductivity 1 Thermal Conductivity, Thermal Diffusivity, Specific Heat 1 Thermal Conductivity, Thermal Diffusivity, Specific Heat 1 Thermal Conductivity, Thermal Resistivity 1 Temperature Range -20 to 70 C -160 to 1000 C -50 to 400 C -40 to 100 C Materials Solids Insulation Solids, Liquids, Pastes, & Powders Liquids and Pastes Soils, Rocks, & Plastics Calibration Single Offset None Absolute Measurement Single Offset Multiple Offset Contact Resistance Removed Through Calibration Removed After Measurement N/A Contact Paste Penetration Depth Entire Sample Up to 180 mm < 1 mm < 50 mm Heterogenous Samples < 20 mm scale < 10 mm scale < 1 mm scale < 10 mm scale Theory Scientifically Reviewed Several Published Papers Several Published Papers Several Published Papers Several Published Papers 14 Specifications sourced from user manuals and available literature.

Methods Comparison LFA GHP GHFM MTPS Accuracy ± 5 to 7% ± 2% ± 5% ± 5 to 15% Measured Property Thermal Diffusivity, Specific Heat 1, Thermal Conductivity 1 Thermal Resistance, Thermal Conductivity 1 Thermal Resistance, Thermal Conductivity 1 Thermal Effusivity, Thermal Conductivity 1 Temperature Range -253 to 2800 C -160 to 600 C -20 to 300 C -50 to 200 C Materials Solids Solids Insulation Solids Solids, Liquids, & Paste Calibration None Absolute Measurement None Absolute Measurement Single Offset Multiple Secondary Contact Resistance Graphite Spray Contact Paste Contact Paste Water & Contact Paste Penetration Depth Entire Sample Entire Sample Entire Sample 0.1 to 3 mm Heterogenous Samples < 0.1 mm scale < 20 mm scale < 5 mm scale < 0.05 mm scale Theory Scientifically Reviewed Several Published Papers Several Published Papers Several Published Papers One Published Paper 1 Italicized property delineates calculated properties. 15

www.thermtest.com info@thermtest.com Toll free: 1-866-249-0077 International: 1-506-458-5350 0207-001-2.0-00