Inline sample preparation for the determination of anions in sodium hydroxide

Similar documents
Using a Reagent-Free ion chromatography system to monitor trace anion contamination in the extracts of electronic components

Separation of heat stable amine salts in methyldiethanolamine (MDEA) solutions using high-pressure IC

Dionex IonPac AS28-Fast-4µm column

Determination of trace concentrations of oxyhalides and bromide in municipal and bottled waters

Determination of Bromate in Bottled Mineral Water Using the CRD 300 Carbonate Removal Device

High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems

Determination of Tetrafluoroborate, Perchlorate, and Hexafluorophosphate in a Simulated Electrolyte Sample from Lithium Ion Battery Production

Determination of trace anions in concentrated hydrofluoric acid

Determination of urea in ultrapure water by IC-MS/MS

New On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography

Determination of Sulfate and Chloride in Ethanol by Ion Chromatography

Determination of Tartaric Acid in Tolterodine Tartrate Drug Products by IC with Suppressed Conductivity Detection

Determinations of Inorganic Anions and Organic Acids in Beverages Using Suppressed Conductivity and Charge Detection

Determination of silicate in high-purity water using ion chromatography and online sample preparation

Application Note 187. Brian DeBorba and Jeff Rohrer Thermo Scientific, Sunnyvale, CA, USA

Determination of Trace Anions in Concentrated Bases Using AutoNeutralization Pretreatment and Ion Chromatography

Determination of trace anions in high-nitrate matrices by ion chromatography

Determination of trace anions in high-purity waters by high volume/direct injection ion chromatography

Determination of trace anions in basic solutions by single pass AutoNeutralization and ion chromatography

Determination of Cations and Amines in Hydrogen Peroxide by Ion Chromatography Using a RFIC (Reagent-Free) System

Determination of Adsorbable Organic Halogen in Wastewater

Time Savings and Improved Reproducibility of Nitrate and Nitrite Ion Chromatography Determination in Milk Samples

Thermo Scientific Dionex IonPac AS23 Anion-Exchange Column

Thermo Scientific Dionex Ion Chromatography Solutions. Global water safety. bromate analysis in drinking water

Thermo Scientific. Anion-Exchange Column

Accurate and Precise Automated Dilution and In-line Conductivity Measurement Using the AS-AP Autosampler Prior to Analysis by Ion Chromatography

The determination of trace anions in concentrated phosphoric acid

Determination of an anionic fluorochemical surfactant in a semiconductor etch bath

Quantification of Trace and Major Anions in Water by Ion Chromatography in a High-Throughput Laboratory

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

columns IonPac AS17-C Anion Exchange Column

Determination of Inorganic Anions in Drinking Water by Ion Chromatography

New Developments in Capillary Ion Chromatography using 4 μm Columns and Charge Detection

Determination of chlorine, bromine, and sulfur in polyethylene materials using combustion IC with a carbonate/bicarbonate eluent

Application of Eluent Generation for Trace Anion Analysis of Borated Waters

anion-exchange column

Determination of Methylamine in Drug Products

Thermo Scientific Dionex IonPac AS25 Anion-Exchange Column. Minutes

Efficient Separations Obtained by Using Smaller Particle Size Analytical Columns with a High-Pressure Ion Chromatography System

Expanded capabilities in ammonium and amine detection

columns IonPac AS18 Anion-Exchange Columns

Trace Level Determination of Bromate in Ozonated Drinking Water Using Ion Chromatography

Overcoming Challenging Matrices in Ion Chromatography

Determination of trace anions in organic solvents using matrix elimination and preconcentration

columns IonPac AS22 Anion-Exchange Column

For new orders of the following parts discussed in this manual, please use the updated part numbers listed below.

Keywords Haloacetic acids, Water analysis, 2-D ion chromatography, ICS-3000

Determination of Silicate in High Purity Water Using Ion Chromatography and AutoPrep

Accurate and Reproducible Determination of Organic Halogens Using Combustion Ion Chromatography

The Determination of Trace Anions in Concentrated Phosphoric Acid

Determination of Inorganic Cations and Ammonium in Environmental Waters by Ion Chromatography Using the IonPac CS16 Column

Determination of trace anions in concentrated glycolic acid

Determination of Trace Anions in Organic Solvents

Determination of Trace Cations in Concentrated Acids Using AutoNeutralization Pretreatment and Ion Chromatography

Anion and Cation analysis with Professional IC - automatic dilution and sample preparation with SPM

Determination of Perchlorate in High Ionic Strength Fertilizer Extracts by Ion Chromatography

Determination of Organic Acids and Inorganic Anions in Lithium-Containing Boric Acid-Treated Nuclear Power Plant Waters

Determination of adsorbable organic halogen in wastewater using a combustion ion chromatography system

Thermo Scientific Dionex IonPac AS24A Anion-Exchange Column

Thermo Scientific Dionex eluent suppressors for ion chromatography

Thermo Scientific Dionex IonPac AS26 Anion-Exchange Column

Determination of Trace Cations in Power Plant Waters Containing Morpholine

Determination of Inorganic Anions in Wastewater by Ion Chromatography

Determination of Organic Acids in Beer Samples Using a High-Pressure Ion Chromatography System

Determination of Hexavalent Chromium in Drinking Water Using Ion Chromatography

Determination of Perchlorate in High Ionic Strength Fertilizer Extracts By Ion Chromatography

Thermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance

Utility of the Charge Detector in Ion Chromatography Applications

Sensitive HILIC UHPLC-UV determination of steviol glycoside natural sweeteners

Direct Determination of Cyanate in a Urea Solution and a Urea-Containing Protein Buffer

Determination of Trace Anions in Concentrated Hydrofluoric Acid

Direct Determination of Small Organic Acids in Sea Water by IC-MS

Thermo Scientific Dionex IonPac AS11-HC-4µm Anion-Exchange Column

Determinations of Heat Stable Amine Salts and Amines in Amine Scrubbing Solutions Using Suppressed Conductivity and Charge Detection

columns IonPac SCS 1 Silica Cation Separator

Waters. Ion Chromatography

The power to increase productivity. Thermo Scientific Dionex Reagent-Free Ion Chromatography (RFIC) System Capabilities

Determination of Monochloroacetic Acid in Carbocisteine

IonPac Trace Cation Concentrator

suppressors Eluent Suppressors for Ion Chromatography

Sample Preparation for Ion Chromatography

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

For new orders of the following parts discussed in this manual, please use the updated part numbers listed below.

Standard Operating Procedure for the Analysis of Chloride, Bromide and Sulfate in Fresh Waters by Ion Chromatography CCAL 50B.2

Application Note 176. Brian DeBorba and Jeff Rohrer Thermo Fisher Scientific, Sunnyvale, CA, USA

Analysis of various clays with Metrohm Combustion IC

ProPac WCX-10 Columns

User Manual. IonPac NS2 Columns Revision 02 October For Research Use Only. Not for use in diagnostic procedures.

Determination of underivatized aflatoxins B2, B1, G2, and G1 in ground hazelnuts by immunoaffinity solid-phase extraction with HPLC-FLD detection

Technical Report. Determination of Nitrite and Nitrate in Smokeless Tobacco Products by Ion Chromatography and Continuous Flow Analysis

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling

Concentrator and Trap Columns. Column: IonPac AG15, AS15, 2 mm. Eluent Source: EG40 Concentrator. Temperature: 30 C Column: IonPac AC15 (2 50 mm)

Determination of Trace Anions in Concentrated Glycolic Acid

Automated, intelligent sample preparation: Integration of the ESI prepfast Auto-dilution System with the Thermo Scientific icap 7400 ICP-OES

Fast methods for the determination of ibuprofen in drug products

Determination of Common Inorganic Anions in Environmental Waters Using a Hydroxide Selective Column

Determination of Polyacrylic Acid in Boiler Water Using Size-Exclusion Chromatography with Charged Aerosol Detection

for IonPac AG11-HC IonPac AS11-HC

ION CHROMATOGRAPHY SYSTEM S 150

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

Transcription:

APPLICATION UPDATE 72331 Inline sample preparation for the determination of anions in sodium hydroxide Authors Hua Yang and Jeff Rohrer Thermo Fisher Scientific, Sunnyvale, CA, USA Keywords Sample preparation, matrix elimination, neutralization, process control, QC, chlor-alkali process, high ph sample, IonPac AS23-4µm, Guardcap H, suppressor, RFIC Goal Develop an easier and better method to determine mg/l concentrations of anions in sodium hydroxide by updating Application Note 51 using Thermo Scientific Dionex Guardcap H vial caps. Introduction Determination of anions in high ph samples is important for a variety of industries. For example, manufacturers of caustics need an accurate method to monitor the concentration of chlorate and other anions in the chlor-alkali process. In chlor-alkali processes, chlorine and sodium hydroxide are produced by the electrolysis of a saturated brine solution. A diaphragm is employed to separate the chlorine generated at the anode and the caustic soda produced at the cathode. Without the diaphragm to isolate the solutions, the chlorine and caustic would react and eventually produce sodium chlorate. Monitoring the chlorate, which results from sodium hydroxide coming into contact with chlorine gas, is critical to ensure the process is working correctly.

However, anions in a high ph sample cannot be determined without proper sample pretreatment due to the high hydroxide concentration in the sample, which can act as an eluent. Application Note (AN51) demonstrated a method to determine anions in sodium hydroxide after manual sample pretreatment with Thermo Scientific Dionex OnGuard II H cartridges. 1 This new application shows an easier method to determine mg/l concentration of anions in sodium hydroxide using automated inline sample preparation with Dionex Guardcap H vial caps. Used with a Thermo Scientific Dionex PolyVial in a Thermo Scientific Dionex AS-DV Autosampler, the Dionex Guardcap H vial caps serve as a cation exchange cartridge to neutralize samples and to remove metals from the samples before loading to the analytical column (Figure 1). Other new technologies and products used in this application include the following: Thermo Scientific Dionex IonPac AS23-4μm column, Thermo Scientific Dionex EGC 500 K 2 Carbonate Eluent Generator Cartridge, and Thermo Scientific Dionex AERS 500 Carbonate Anion Electrolytically Regenerated Suppressor for Carbonate Eluents. If determination of µg/l concentrations of anions in caustic solution is required, please see Application Note 93. 2 Experimental Equipment Thermo Scientific Dionex ICS-5000 + Reagent-Free Ion Chromatography (RFIC) HPIC System* equipped with the following for carbonate/bicarbonate eluent generation and suppression: Thermo Scientific Dionex EGC 500 K 2 Carbonate Eluent Generator Cartridge Guardcap Sample-out line Needle Sample tip Cap Guardcap sample prep filter Sample entrance Sample Dionex EPM 500 Electrolytic ph Modifier Dionex EGC 500 Carbonate Mixer Kit, 4 mm Thermo Scientific Dionex AERS 500 Carbonate Anion Electrolytically Regenerated Suppressor for carbonate eluents, 4 mm Thermo Scientific Dionex AS-DV Autosampler (P/N 068907) with 70 cm sample transfer line (P/N 22120-60055) and 5.0 ml vial holder (P/N 068947). *Equivalent results can be achieved using the Thermo Scientific Dionex Integrion HPIC system. Vial Concave bottom to match cap Figure 1. Illustration of the Dionex Guardcap H vial cap with Dionex PolyVial for AS-DV autosampler. 2

Consumables Table 1 lists the consumable products needed. Table 1. Consumables list. Product Name Description Part Number Dionex EGC 500 K 2 Carbonate Eluent Generator Cartridge Eluent generator cartridge 088453 Dionex EPM 500 Electrolytic ph Modifier ph Modifier 088471 Dionex EGC 500 Carbonate Mixer Kit, 4 mm Carbonate Mixer Kit 088468 Thermo Scientific Dionex AERS 500 Carbonate Anion Electrolytically Regenerated Suppressor for Carbonate Eluents (4 mm) Anion Electrolytically Regenerated Suppressor, 4 mm, for carbonate/bicarbonate eluents up to 15 mm 085029 Dionex High Pressure RFIC + Eluent Degasser RFIC + eluent degasser 075522 Dionex IonPac AG23-4µm Column, 4 mm Guard column, 4 50 mm 302556 Dionex IonPac AS23-4µm Column, 4 mm Separator column, 4 250 mm 302555 Thermo Scientific Dionex IC Viper Fitting Tubing Assembly Kits Thermo Scientific Nalgene Syringe Filter Dionex Guardcap H Vial Caps 70 cm Reduced Volume Sample Transfer Line Assembly Dionex Viper Fitting Kit for Dionex Integrion System configured for eluent generation and conductivity detection. Includes one each of P/Ns: 088805 088811 Syringe filters, 25 mm, PES membrane, 0.2 μm H + -Functionalized Vial Cap, 5 ml, for use with 5 ml Dionex PolyVials, Package of 125 Recommended for use with injection valves mounted in IC systems 088798 Thermo Scientific 725-2520 / Fisher Scientific 09-740-113 302504 22120-60055 PolyVials PolyVial, 5 ml, Package of 250 038008 Plain Cap Vial Cap, plain, no filter, 5 ml, Package of 250 039528 Plastic Bottle Nalgene Narrow-Mouth PPCO Economy Bottles with Closure, 125 ml, Case of 72 Tool, Insertion Use for Vial Cap insertion 037987 Thermo Scientific 2087-0004 Software Thermo Scientific Chromeleon Chromatography Data System (CDS) software, version 7.2 SR4 Reagents, samples and standards Deionized (DI) water, Type I reagent grade, 18 MΩ cm resistivity or better Sodium or potassium salts, A.C.S. reagent grade or better, for preparing anion standards Thermo Scientific Dionex Stock Solutions: Combined Five Anion Standard (Thermo Scientific P/N 037157) Fluoride Standard (Thermo Scientific P/N 037158) Chloride Standard (Thermo Scientific P/N 037159) Sulfate Standard (Thermo Scientific P/N 037160) Combined Seven Anion Standard (Thermo Scientific P/N 056933 or P/N 057590) Sodium hydroxide solution (50% w/w/certified) (Fisher Scientific, P/N SS254-500) S1: Lot # 107305 S2: Lot # 154087 3

Conditions Columns: Dionex IonPac AG23-4µm, and Dionex IonPac AS23-4µm, 4 mm (i.d.) column set Eluent: 4.5 mm K 2 /0.8 mm KH Eluent Source: Dionex EGC 500 K 2 Cartridge with Dionex EPM 500, Dionex carbonate mixer, and Dionex high pressure RFIC + eluent degasser Flow Rate: 1.0 ml/min Delivery Speed: AS-DV, 1.0 ml/min Delivery Volume: AS-DV, 350 µl Injection Volume: 100 µl (Full loop) Column Temperature: 30 C Detection: Suppressed conductivity, Dionex AERS 500 Carbonate, 4 mm, 30 C, 32 ma, recycle mode Background: < 17.5 µs Noise: < 2 ns Backpressure: ~ 3200 psi Run Time: 25 min Preparation of standards and reagents Stock standard solutions Prepare 1000 ppm stock standard solutions of fluoride, chlorite, bromate, chloride, nitrite, chlorate, bromide, nitrate, phosphate, and sulfate by accurately weighing the amounts of reagent-grade salts provided in Table 2, and dissolving the salt in 100 g of DI water in a 125 ml polypropylene bottle. Use Thermo Scientific Stock Solutions as available. Stock standard solutions are stored in plastic containers at 4 C. The chlorite standard is stable for two weeks. The nitrite and phosphate standards are stable for one month. The other stock standards are stable for three months. Table 2. Mass of compound required to prepare 100 ml of a 1000 ppm solution. Anion Compound* Mass (g) Fluoride Sodium fluoride (NaF) 0.221 Chlorite Sodium chlorite (NaClO 2 ) 0.134 Bromate Sodium bromate (NaBrO 3 ) 0.180 Chloride Sodium chloride (NaCl) 0.165 Nitrite Sodium nitrite (NaNO 2 ) 0.150 Chlorate Sodium chlorate (NaClO 3 ) 0.128 Bromide Sodium bromide (NaBr) 0.129 Nitrate Sodium nitrate (NaNO 3 ) 0.137 Sulfate Sodium sulfate (Na 2 SO 4 ) 0.148 Phosphate Sodium phosphate, monobasic (NaH 2 PO 4 ) 0.124 *Compound must be dry. Working standard solutions Prepare working standards by diluting appropriate volumes of the 1000 ppm stock standards with DI water. Prepare working standards daily if they contain less than 1 ppm of chlorite and nitrite. Prepare seven levels of mixed calibration standards for determining nine anions. The highest concentration mixed standard stock is prepared first. In a 125 ml polypropylene bottle, add 0.200 ml of fluoride, 1.000 ml each of bromate, chloride, chlorate, nitrite, bromide and sulfate, and 2.000 ml of phosphate stock solutions, and then add DI water to a final volume of 100 ml (100.0 g on a top loading balance). Dilute this standard with DI water as shown in Table 3 to make the remaining mixed standards. Final concentrations are shown in Table 3. Prepare a different set of calibration standards for chlorite. Chloride is the major impurity in sodium chlorite solid. Therefore, chlorite and chloride should not be simultaneously included in a mixed calibration standard. Adding chlorite into the mixed calibration standards listed in Table 3 will result in an incorrect amount of chloride. Make chlorite calibration standards using similar procedures. Add 1.000 ml of chlorite 1000 ppm stock solution into 99.00 ml of DI water to make a high concentration standard. Dilute it as shown in Table 4 to make the other calibration standards. 4

Table 3. Seven levels of mixed calibration standards for determining nine anions (ppm). Dilution of Mixed Stock 1:1000 1:100 1:20 1:10 1:5 1:2 No Dilution Level 1 Level 2 Level 3 Level 4 Level 5 Level 6 Level 7 Fluoride 0.002 0.02 0.1 0.2 0.4 1 2 Bromate 0.01 0.1 0.5 1 2 5 10 Chloride 0.01 0.1 0.5 1 2 5 10 Nitrite 0.01 0.1 0.5 1 2 5 10 Chlorate 0.01 0.1 0.5 1 2 5 10 Bromide 0.01 0.1 0.5 1 2 5 10 Nitrate 0.01 0.1 0.5 1 2 5 10 Phosphate 0.02 0.2 1 2 4 10 20 Sulfate 0.01 0.1 0.5 1 2 5 10 Table 4. Seven levels of calibration standards for determining chlorite (ppm). 1:1000 1:100 1:20 1:10 1:5 1:2 No Dilution Level 1 Level 2 Level 3 Level 4 Level 5 Level 6 Level 7 Chlorite 0.01 0.1 0.5 1 2 5 10 Sample preparation Prepare the sample by diluting the samples with DI water. The 50% w/v NaOH (19.1 N) is diluted 1:500 (0.038 N) to ensure that the capacity of the Dionex Guardcap H vial caps is not exceeded. Spike the sample by adding the concentrated mixed standard into 50% w/v NaOH before dilution. System preparation and configuration Set up the Dionex AS-DV autosampler according to product manual for Dionex Guardcap H vial caps. 3 Make sure a reduced volume sample transfer line is installed in the Dionex AS-DV autosampler and that the Chromeleon CDS software instrument method includes the sample delivery flow rate set at 1 ml/min and a sample delivery volume of 350 µl. Install and condition the Dionex EGC 500 K 2 Carbonate Eluent Generator Cartridge with Dionex EPM 500 as described in the Quick Start. 4 Install and hydrate the Dionex AERS 500 Carbonate Anion Electrolytically Regenerated Suppressor. 5 Finish the system setup according to the product manuals and the Dionex ICS-5000 + HPIC system Operator s Manual 6 (Figure 2). Install and condition the guard and separator columns at least 30 min prior to installing the columns in line with the suppressor. 7 Although the data in this application update were collected with eluent generation, this method can also be executed with a manually prepared 4.5 mm Na 2 /0.8 mm NaH eluent. 5

EGC 500 K 2 Cartridge Waste 1. EPM Eluent Inlet 2. EPM Eluent Outlet 3. Degas Eluent-In 4. Degas Eluent-Out 5. Suppressor Eluent-In 6. Suppressor Eluent-Out 7. Suppressor Regen-In 8. Suppressor Regen-Out 9. EPM Regen-In 10. EPM Regen-Out Pump H 2 O Inlet Outlet 9 10 EPM 500 1 2 Degasser Assembly 3 4 Vent EGC 500 Carbonate Mixer Backpressure Coil Conductivity Detector 6 7 8 Electrolytic Suppressor 5 Separation Column Injector Figure 2. Flow diagram of the RFIC system. Method detection limit calculation The method detection limit (MDL) is defined as the minimum concentration of an analyte that can be identified, measured, and reported with 99% confidence that the analyte concentration is greater than zero. To establish the single operator, within-day MDL for each analyte, make seven replicate injections of DI water fortified with each analyte at a concentration of three to five times the estimated instrument detection limit. 8 Here, seven replicate injections of level 1 standards, one for nine anions, and one for chlorite, are used for MDL determination. Because the sample is diluted 1:500, the MDL is multiplied by 500 to reflect the dilution. MDL = 500 3.14 σ. Results and discussion With automated inline sample preparation using Dionex Guardcap H vial caps and electrolytic generation of eluents using a Dionex EGC 500 K 2 Eluent Generator Cartridge with a Dionex EPM 500, the determination of anions in sodium hydroxide is made simple and easy. The 50% w/v sodium hydroxide sample required dilution with DI water before analysis. Because the capacity of a Dionex Guardcap H vial cap is lower than that of a Dionex OnGuard II H cartridge, the 1:50 dilution as used in AN51 is not sufficient for the current application. As discussed in the Dionex Guardcap H vial cap manual, 3 the capacity of the Dionex Guardcap H vial cap for metal removal and neutralization of high ph samples using the Dionex AS-DV autosampler at the flow rate of 1 ml/min is about 500 µl of 50 mm NaOH. If the alkaline concentration of the high ph sample is greater than 50 mm, the sample should be diluted before using the Dionex Guardcap H vial caps. Here, the 50% w/w NaOH (19.1 N) was first diluted 1:500 (0.038 N) to ensure the capacity of Dionex Guardcap H vial cap was not exceeded and the injection volume was increased from 25 μl to 100 µl. Note that the sample delivery volume in the instrument method is the amount of sample filtered through the Dionex Guardcap H vial cap; only part of the delivered sample is injected onto the column (injection volume), i.e., the volume of the injection loop installed on the injection valve. The first step was to determine if inline sample preparation using Dionex Guardcap H vial caps made a difference in the anion analysis results. Figure 3 compares the chromatograms of samples of mixed anions in a high-ph matrix with and without using Dionex Guardcap H vial caps for sample preparation. The chromatogram for direct injection (without Dionex Guardcap H vial caps) gives lower efficiency and baseline disturbances compared to the treated sample, adversely affecting quantification of analytes. 6

Columns: Dionex IonPac AG23-4µm, and Dionex IonPac AS23-4µm, 4 mm Columns: Dionex IonPac AG23-4µm, and Dionex IonPac AS23-4µm, 4 mm 25 µs B Eluent: 4.5 mm K 2 /0.8 mm KH Eluent Source: Dionex EGC 500 K 2 Cartridge with Dionex EPM 500, mixer and Dionex high pressure degasser Flow Rate: 1.0 ml/min Inj. Volume: 100 µl Column Temp.: 30 C Detection: Suppressed conductivity, Dionex AERS 500 carbonate, 4 mm, 30 C, 25 ma, recycle mode Sample: Mixed standard in 500 dilution of 50% NaOH (0.0382N). A- Inject with Dionex Guardcap H vial cap B- Inject with plain vial cap Peaks: ppm 1. Fluoride 1 2. Chlorite 5 3. Bromate 5 4. Chloride 5 4 5. Nitrite 5 6. Chlorate 5 7. Bromide 5 8. Nitrate 5 9. Carbonate - 10. Phosphate 10 11. Sulfate 5 25 µs 1 3 4 Eluent: 4.5 mm K 2 /0.8 mm KH Eluent Source: Dionex EGC 500 K 2 Cartridge with Dionex EPM 500, mixer and Dionex high pressure degasser Flow Rate: 1.0 ml/min Inj. Volume: 100 µl Column Temp.: 30 C Detection: Suppressed conductivity, Dionex AERS 500 carbonate, 4 mm, 30 C, 25 ma, recycle mode Sample : Mixed standard treated with Dionex Guardcap H A- in 500 diluted NaOH (0.0382N) B- in DI water Peaks: A B (ppm) 1. Fluoride 1 1 2. Chlorite 5 0 3. Bromate 5 5 4. Chloride 5 5 5. Nitrite 5 5 6. Chlorate 5 5 7. Bromide 5 5 8. Nitrate 5 5 9. Carbonate - 10. Phosphate 10 10 11. Sulfate 5 5 5 8 6 7 11 10 5 1 2 3 6 7 8 10 11 B 2 9 0 A 9 0 A -5 0 5 10 15 20 25 Minutes Figure 3. Improved chromatogram of mixed anions in a high-ph sample using Dionex Guardcap H vial caps for inline sample pretreatment. -5 0 5 10 15 20 25 Minutes Figure 4. Chromatograms of mixed anions samples in high-ph and in neutral matrices. Next, the effect of Dionex Guardcap H vial caps on different sample matrices was determined. The two chromatograms shown in Figure 4 were generated by treating mixed anion samples through Guardcap H vial caps. Sample A has a high ph matrix and Sample B has a deionized water matrix. Chlorite was omitted in Sample B because it is also used as the level six mixed calibration standard for anions, and addition of chlorite will result in incorrect chloride determination. The two chromatograms are almost identical in terms of retention time, peak shape, peak response, and peak efficiency. This indicates that the adverse high-ph effect on determination of anions is completely reversed or neutralized by the Dionex Guardcap H vial caps; the correct concentration of anions in a sodium hydroxide solution can be easily determined without manual neutralization. 7

Before conducting sample analyses, calibration and performance of the method were demonstrated. Table 5 shows the method linearity, retention time precision, and detection limit (MDL). For the measured range, the method is linear for all anions (r 2 0.997). The linear calibrations for all anions were also demonstrated by their calibration plots (Figure 5). The retention times are precise (RSDs < 0.1 with the exception of sulfate < 0.2). The MDLs were determined by injecting level 1 mixed standards (n = 7). The method is sensitive with MDL < 3 ppm for most anions. Table 5. Method linearity, retention time precision, and detection limit (MDL). Analyte Calibration Range (ppm) Coefficient of Determination ( r 2 ) Retention Time Precision (RSD) * MDL Standard (ppm) MDL** (ppm) Fluoride*** 2-0.02 0.999 <0.1 0.002 2 Chlorite 10-0.01 0.998 <0.1 0.01 3 Bromate 10-0.01 1.000 <0.1 0.01 2 Chloride 10-0.01 0.997 <0.1 0.01 1 Nitrite 10-0.01 1.000 <0.1 0.01 1 Chlorate 10-0.01 0.999 <0.1 0.01 2 Bromide 10-0.01 0.999 <0.1 0.01 2 Nitrate 10-0.01 0.997 <0.1 0.01 1 Phosphate 20-0.02 0.999 <0.1 0.02 3 Sulfate 10-0.01 0.999 <0.2 0.01 2 *RSD = relative standard deviation of 7 levels, n = 3 for each level. ** For 100 µl injection and 500 fold sample dilution, MDL = 500 3.14 σ when n = 7. *** MDL of fluoride is determined by the signal to noise ratio (S/N) of the level 2 standard. ppm ppm ppm ppm ppm ppm Figure 5A. Calibration plots illustrating linearity. 8

ppm ppm ppm ppm Figure 5B. Calibration plots illustrating linearity. The method performance was measured by determining recovery of spiked samples. Table 6 shows analyte amounts found in two different lots of 50% w/v NaOH, S1 and S2, and recovery of 10 ppm anions spiked into these two samples. The recoveries for chlorite, bromate, chloride, nitrite, chlorate, and bromide are from 71% to 127%. The relatively large range of recovery is reasonable for such a low level spike. These spikes are close to the low detection range at about 5 to 10 times the MDL. The method is accurate. Table 6. Recovery of 10 ppm of chlorite, bromate, chloride, nitrite, chlorate, and bromide spiked into 50% w/w NaOH. Chlorite* Bromate Chloride Nitrite Chlorate Bromide Amount Found (ppm) in S1 <MDL <MDL 3 <MDL <MDL <MDL 80 103 94 99 101 96 Recovery (%) 109 118 112 97 127 112 109 Amount Found (ppm) in S2 <MDL <MDL 2 <MDL <MDL <MDL 91 93 86 111 98 107 93 83 109 100 110 87 82 89 96 Recovery (%) 91 89 92 104 90 105 107 114 92 91 84 125 107 106 100 99 71 97 118 114 89 81 88 * Bromate, chloride, nitrite, chlorate, and bromide were spiked together using mixed anion standards. Chlorite was spiked separately. 9

Conclusion This application uses a Dionex Reagent-Free Ion Chromatography (RFIC) system with Dionex Guardcap H vial caps on Dionex PolyVials for the Dionex AS-DV autosamplers to determine anions in a sodium hydroxide matrix. With automated inline sample preparation and electrolytic generation of eluents, the new method is easier and simpler compared to the method outlined in AN51, which uses the offline sample preparation cartridge, Dionex OnGuard II H. For target anions (chlorite, bromate, chloride, nitrite, chlorate, and bromide) in the measured range (5 to 5000 ppm), the method is linear (r 2 0.997), sensitive (MDL < 3 ppm), and accurate (recovery 71% to 127%). References 1. Thermo Scientific Application Note 51: Method for Determination of Anions in Sodium Hydroxide. Sunnyvale, CA, 2003. [Online] http://tools.thermofisher.com/content/sfs/ brochures/4657-an51_ic_anions_naoh_19aug03_lpn1552.pdf (accessed Mar. 27, 2017). 2. Thermo Scientific Application Note 93: Determination of Trace Anions in Concentrated Bases Using Auto Neutralization Pretreatment and Ion Chromatography. Sunnyvale, CA, 2007. [Online] http://tools.thermofisher.com/content/sfs/brochures/4176- AN93_21May07_LPN1886-R2.pdf (accessed Mar. 27, 2017). 3. Thermo Scientific Product Manual for Dionex Guardcap H. Sunnyvale, CA, 2016. [Online] https://tools.thermofisher.com/content/sfs/manuals/man-065705-guardcap- H-Vial-Caps-Man065705-EN.pdf (accessed Mar. 27, 2017). 4. Thermo Scientific Eluent Generator Cartridge (EGC) 500 K2CO3 High Pressure Electrolytic ph Modifier (EPM) 500 Quick Start. Sunnyvale, CA, 2014. [Online] https:// tools.thermofisher.com/content/sfs/manuals/qs-065084-egc-iii-k2co3-qs- 065084-EN.pdf (accessed Mar. 27, 2017). 5. Thermo Scientific Product Manual for Dionex ERS 500 Electrolytically Regenerated Suppressor. Sunnyvale, CA, 2014. [Online] https://tools.thermofisher.com/content/sfs/ manuals/man-031956-ic-dionex-ers-suppressor-man031956-en.pdf (accessed Mar. 27, 2017). 6. Thermo Scientific Dionex ICS-5000+ Ion Chromatography System Operator s Manual. Sunnyvale, CA, 2014. [Online] https://tools.thermofisher.com/content/sfs/manuals/ Man-065446-IC-ICS-5000+-Operators-Manual.pdf (accessed Mar. 27, 2017). 7. Thermo Scientific Dionex IonPac AS23-4μm and Dionex IonPac AG23-4µm Guard Column Product Manual. Sunnyvale, CA, 2016. [Online] https://tools.thermofisher.com/ content/sfs/manuals/man-065711-ionpac-as23-4um-man065711-en.pdf (accessed Mar. 27, 2017). 8. U.S. Environmental Protection Agency. 40 CFR Appendix B to Part 136 Definition and Procedure for the Determination of the Method Detection Limit, Revision 1.11, 2011. [Online] https://www.gpo.gov/fdsys/pkg/cfr-2011-title40-vol23/pdf/cfr-2011- title40-vol23-part136-appb.pdf (accessed Mar. 27, 2017) Find out more at thermofisher.com 2017 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific and its subsidiaries. This information is presented as an example of the capabilities of Thermo Fisher Scientific products. It is not intended to encourage use of these products in any manners that might infringe the intellectual property rights of others. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representatives for details. AU723315-EN 0617S