A semi-active rocking system for wind turbines under extreme wind loads

Similar documents
A STUDY AND DEVELOPMENT OF SEMI-ACTIVE CONTROL METHOD BY MAGNETORHEOLOGICAL FLUID DAMPER IN BASE ISOLATED STRUCTURES

Comparison between the visco-elastic dampers And Magnetorheological dampers and study the Effect of temperature on the damping properties

Open Access Semi-active Pneumatic Devices for Control of MDOF Structures

Dynamics of Ocean Structures Prof. Dr. Srinivasan Chandrasekaran Department of Ocean Engineering Indian Institute of Technology, Madras

Vibration Control of Building Subjected to Harmonic Excitation

Earthquake Loads According to IBC IBC Safety Concept

Fundamental study on simple quantitative approach of damping performance for semi-active damper

Experimental Investigation of the Performances of a WRS-BTU Seismic Isolator

STRUCTURAL CONTROL USING MODIFIED TUNED LIQUID DAMPERS

Influence of residual stresses in the structural behavior of. tubular columns and arches. Nuno Rocha Cima Gomes

Wire rope springs for passive vibration control of a light steel structure

1.1 OBJECTIVE AND CONTENTS OF THE BOOK

A new seismic testing method E. Kausel Professor of Civil and Environmental Engineering, Massachusetts 7-277, OamWd^e, ^ 027 JP,

STUDY ON APPLICABILITY OF SEMI-ACTIVE VARIABLE DAMPING CONTROL ON BRIDGE STRUCTURES UNDER THE LARGE EARTHQUAKE MOTION

Dynamic Modelling of Mechanical Systems

DEVELOPMENT OF A REAL-TIME HYBRID EXPERIMENTAL SYSTEM USING A SHAKING TABLE

Shape Optimization of Revolute Single Link Flexible Robotic Manipulator for Vibration Suppression

Introduction to Mechanical Vibration

Dynamic behavior of turbine foundation considering full interaction among facility, structure and soil

Inclusion of a Sacrificial Fuse to Limit Peak Base-Shear Forces During Extreme Seismic Events in Structures with Viscous Damping

AdaptiveImpact Absorption. Smart Technology Centre

ASEISMIC DESIGN OF TALL STRUCTURES USING VARIABLE FREQUENCY PENDULUM OSCILLATOR

Structural Dynamics of Offshore Wind Turbines subject to Extreme Wave Loading

Simulating Two-Dimensional Stick-Slip Motion of a Rigid Body using a New Friction Model

New Representation of Bearings in LS-DYNA

DYNAMIC RESPONSE OF EARTHQUAKE EXCITED INELASTIC PRIMARY- SECONDARY SYSTEMS

Hysteresis Modelling of an MR Damper Applied to Suspension System

Time-Varying Dynamic Properties of Offshore Wind Turbines Evaluated by Modal Testing

(Refer Slide Time: 00:01:30 min)

Vibration Control Effects of Tuned Cradle Damped Mass Damper

Aseismic design of structure equipment systems using variable frequency pendulum isolator

DEVELOPMENT OF A LARGE SCALE HYBRID SHAKE TABLE AND APPLICATION TO TESTING A FRICTION SLIDER ISOLATED SYSTEM

EN40: Dynamics and Vibrations. Final Examination Wed May : 2pm-5pm

To Control Vibration of Cable-stayed Bridges by Semi-active Damper and Lyapunov Control Algorithm

Pseudo-dynamic tests in centrifugal field for structure-foundation-soil systems

SEISMIC BASE ISOLATION

Modeling of the hysteretic dynamic behavior of the Stockbridge messenger cables

A comparison study of the two-bladed partial pitch turbine during normal operation and an extreme gust conditions

Stockbridge-Type Damper Effectiveness Evaluation: Part II The Influence of the Impedance Matrix Terms on the Energy Dissipated

CFD DESIGN OF A GENERIC CONTROLLER FOR VORTEX-INDUCED RESONANCE

MOOC QP Set 2 Principles of Vibration Control

Vibration Analysis. with SOLIDWORKS Simulation 2018 SDC. Paul M. Kurowski. Better Textbooks. Lower Prices.

Passive Control of the Vibration of Flooring Systems using a Gravity Compensated Non-Linear Energy Sink

Structural Dynamics Lecture 2. Outline of Lecture 2. Single-Degree-of-Freedom Systems (cont.)

EXPLICIT EQUIVALENT FORCE CONTROL FOR REAL-TIME SUBSTRUCTURE TESTING

Preliminary Examination - Dynamics

DYNAMIC RESPONSE OF INELASTIC BUILDING- FOUNDATION SYSTEMS

Numerical Study on Performance of Innovative Wind Turbine Blade for Load Reduction

SEISMIC RESPONSE OF SINGLE DEGREE OF FREEDOM STRUCTURAL FUSE SYSTEMS

Structural Control: Introduction and Fruitful Research Areas

Earthquake Excited Base-Isolated Structures Protected by Tuned Liquid Column Dampers: Design Approach and Experimental Verification

Alireza Mousavi Brunel University

This equation of motion may be solved either by differential equation method or by graphical method as discussed below:

Real-Time Hybrid Simulation of Single and Multiple Tuned Liquid Column Dampers for Controlling Seismic-Induced Response

(Refer Slide Time: 1: 19)

COMPARISON BETWEEN 2D AND 3D ANALYSES OF SEISMIC STABILITY OF DETACHED BLOCKS IN AN ARCH DAM

Vertical acceleration and torsional effects on the dynamic stability and design of C-bent columns

Performance of a Vertical Axis Wind Turbine under Accelerating and Decelerating Flows

REPRODUCTION OF A LARGE-SCALE 1G TEST ON UNSATURATED SAND DEPOSITS AND PILE FOUNDATIONS USING CENTRIFUGE MODELING

Model tests and FE-modelling of dynamic soil-structure interaction

The use of a floating quay for container terminals. 1. Introduction

Index. Index. More information. in this web service Cambridge University Press

Numerical Modeling of Interface Between Soil and Pile to Account for Loss of Contact during Seismic Excitation

Response Analysis for Multi Support Earthquake Excitation

2007 Problem Topic Comment 1 Kinematics Position-time equation Kinematics 7 2 Kinematics Velocity-time graph Dynamics 6 3 Kinematics Average velocity

Impact Simulation of Extreme Wind Generated Missiles on Radioactive Waste Storage Facilities

International Journal of Advance Engineering and Research Development

Numerical crashworthiness analysis of an offshore wind turbine monopile impacted by a ship

TOPIC E: OSCILLATIONS EXAMPLES SPRING Q1. Find general solutions for the following differential equations:

Damping Performance of Taut Cables with Passive Absorbers Incorporating Inerters

Dynamics and Control of the GyroPTO Wave Energy Point Absorber under Sea Waves

Evaluation of dynamic behavior of culverts and embankments through centrifuge model tests and a numerical analysis

Lecture Module 5: Introduction to Attitude Stabilization and Control

Effects of Damping Ratio of Restoring force Device on Response of a Structure Resting on Sliding Supports with Restoring Force Device

APVC2013. Twin Rotor Damper for Control of Wind-Induced Bridge Deck Vibrations. Jörn SCHELLER * and Uwe STAROSSEK ** 1.

Dynamic Loads CE 543. Examples. Harmonic Loads

Effect of Dampers on Seismic Demand of Short Period Structures

D : SOLID MECHANICS. Q. 1 Q. 9 carry one mark each.

Engineering Tripos Part IB. Part IB Paper 8: - ELECTIVE (2)

Modeling, Control and Experimental Validation of a Device for Seismic Events Simulation

A novel tuned liquid wall damper for multi-hazard mitigation

Implementation of an advanced beam model in BHawC

Energy balance in self-powered MR damper-based vibration reduction system

Investigation of fan vibration

Introduction to structural dynamics

Final Examination Thursday May Please initial the statement below to show that you have read it

Engineering Mechanics Prof. U. S. Dixit Department of Mechanical Engineering Indian Institute of Technology, Guwahati Introduction to vibration

A comparison study of the two-bladed partial pitch turbine during normal operation and an extreme gust conditions

Foundation Engineering Dr. Priti Maheshwari Department Of Civil Engineering Indian Institute Of Technology, Roorkee

Numerical Study on Performance of Curved Wind Turbine Blade for Loads Reduction

Dynamic Response Of Laminated Composite Shells Subjected To Impulsive Loads

Due Date 1 (for confirmation of final grade): Monday May 10 at 11:59pm Due Date 2 (absolute latest possible submission): Friday May 14 at 5pm

Structural Dynamics Lecture 4. Outline of Lecture 4. Multi-Degree-of-Freedom Systems. Formulation of Equations of Motions. Undamped Eigenvibrations.

FEA A Guide to Good Practice. What to expect when you re expecting FEA A guide to good practice

Aeroelastic effects of large blade deflections for wind turbines

Lecture 19. Measurement of Solid-Mechanical Quantities (Chapter 8) Measuring Strain Measuring Displacement Measuring Linear Velocity

Towards Pitch-Scheduled Drive Train Damping in Variable-Speed, Horizontal-Axis Large Wind Turbines

Self-powered and sensing control system based on MR damper: presentation and application

D : SOLID MECHANICS. Q. 1 Q. 9 carry one mark each. Q.1 Find the force (in kn) in the member BH of the truss shown.

Dynamics of Ocean Structures Prof. Dr. Srinivasan Chandrasekaran Department of Ocean Engineering Indian Institute of Technology, Madras

Transcription:

EACS 216 6 th European Conference on Structural Control Sheffield, England: 11-13 July 216 Paper No. 189 A semi-active rocking system for wind turbines under etreme wind loads Nicola Caterino 1,4, Christos T. Georgakis 2, Mariacristina Spizzuoco 3, Antonio Occhiuzzi 4,1 1 Department of Civil Engineering, University of Naples Parthenope, Italy 2 Department of Civil Engineering, Technical University of Denmark (DTU), Denmark 3 Department of Structures for Engineering and Architecture, University of Naples Federico II, Italy 4 Construction Technologies Institute, Italian National Research Council (CNR), Italy ABSTRACT In the last decades, the negative impact of the use of fossil fuels on the environment has lead to a boom in the production of wind turbines. Then, wind turbine heights are progressively increasing in order to take advantage of the smoother winds at higher altitude. But, this has led to an increased demand to control tower forces. The application of a semi-active (SA) control system is herein proposed and discussed. Its aim is to limit bending moment demand at the base of a wind turbine by relaing the base restraint of the turbine s tower, without increasing the top displacement, thanks to the sharp increase of dissipated energy in selected intervals of time and a consequent change in tower dynamic properties. The proposed SA control system reproduces a variable restraint at the base that changes in real time its mechanical properties according to the instantaneous response of the turbine s tower. This smart restraint is made of a central smooth hinge, elastic springs and SA magnetorheological dampers driven by a properly designed control algorithm. A commercial 15 m tall wind turbine has been assumed as a case study. Several numerical simulations have been performed with reference to an etreme load, aimed at establishing a procedure for the optimal calibration of the control algorithm according to the specific case, finally proving the actual potential of the proposed control technique in reducing the structural demand with respect to the fied base structure. Keywords: Semi-active control, rocking control system, wind turbine, magnetorheological damper 1 INTRODUCTION Due to the increasing height of wind turbines, wind turbine manufacturers have become ever more interested in methods for reducing or limiting tower base moments. There are two main reasons for this. First, the tower diameters at the base are increasing beyond the point where they can be fabricated off-site and shipped to the location of installation, so that construction costs and compleity are significantly increasing. Second, the tower diameters and associated base moments of newer wind turbines far eceed those of eisting wind turbines that the newer ones hope to replace. Therefore, eisting foundations cannot be utilized and new or strengthened foundations need to be constructed. The maimum base moments of a wind-turbine are generated by very specific, almost improbable, load cases. These include the load cases which involve etreme gusts of wind 1 Assistant professor, nicola.caterino@uniparthenope.it 2 Professor, cg@byg.dtu.dk 3 Technical Engineer Officer, spizzuoc@unina.it 4 Professor, occhiuzzi@itc.cnr.it * Corresponding author 1

combined with emergency shut-down procedures. All the etreme load cases are short duration impulse loads which generate maimum epected tower base moments; this cannot be combated using traditional damping devices. As damping is generally considered ineffective for impact type loading, a variable tower stiffness and damping approach needs to be followed. In this paper, the concept of an adaptive wind turbine tower is eamined, where the adaptation is realized through the implementation of a semi-active (SA) control system. Chen and Georgakis [1] performed an eperimental analysis of a 1/2-scale wind tower model equipped with a passive rolling-ball damper to reduce vibrations. Such damper consists of a glass container placed at the top of the model and having one or more steel balls inside. Different configurations have been tested, changing the geometry of the container (one or two layers) and the number of balls (one to si) placed inside, showing a significant reduction of the peak value and standard deviation of top displacement and base bending moment. The same authors [2] tested the same model using water rather than steel balls inside the glass container, i.e. realizing a spherical tuned liquid damper. The optimal degree of filling with water (1-2% of the total generalized mass of the system) has been found as leading to the maimum reduction of structural demand. As regard active/semi-active control strategies from literature related to wind turbines, Karimi et al. [3] and Luo et al. [4] propose a SA control technique for floating wind turbines with TLCD. This device, generally used as a passive damper, turns into a SA device using a controllable valve. The orifice opening is real time adapted according to the structure response and loading conditions, with a control logic based on a H feedback methodology. Lackner and Rotea [5] investigate the effectiveness of an optimal passive TMD and of a hybrid mass damper (HMD, i.e. a TMD improved with the addition of a controlled force actuator) in reducing fatigue loads due to bending moment at the base of the tower, showing a percentage reduction of about 1% and 3% respectively due to each of the two proposed systems. Kirkegaard et al. [6] have been the first to eplore the use of magnetorheological (MR) dampers to control a wind turbine, assuming such type of smart device to be installed, in a vertical position, between the base and the top of the tower. Even hard to be implemented in a real case, the numerical simulations show good results. Eperimental results are also made available by the authors, unfortunately referred to the passive use (constant voltage fed to the MR damper) of the device only. The authors recently proposed a SA control system based on the application of MR devices to realize a time-variant base restraint whose stiffness can be driven in real time by a properly written control logic [7, 8]. The controller has to be programmed to instantaneously calibrate the MR devices installed at the base of the tower in order to reduce the base bending moment, relaing in selected intervals of time the base restraint. Again, the control logic has to hold the top displacement within acceptable values so as to avoid significant, detrimental second order effects. At the laboratory of the Denmark Technical University (DTU) in Copenaghen, some preliminary shaking table tests of a wind turbine tower model semi-actively controlled as above has been recently performed by the authors. After the formulation of the above idea, a finite element model of the structure has been calibrated so as to develop several numerical simulations addressed to optimally calibrate the control logic properly designed for such kind of applications. 2 A SEMI-ACTIVE ROCKING SYSTEM FOR HIGH WIND TURBINES A semi-active rocking system, eploiting controllable fluid based devices, is proposed as base restraint of the high-rise wind turbine towers, with the aim of reducing their wind induced structural demand. This is schematically shown in Fig. 1, where the uncontrolled wind turbine, fully restrained at the base, is modeled as a single degree of freedom dynamic system (Fig. 1(a)), having top mass m, stiffness kt and inherent damping ct. In order to control the structural demand, the authors proposed to replace the perfectly rigid base restraint with a smart one that is able to instantaneously become more or less stiff, during the motion. Fig. 1(b) just sketches that it is possible to realize this idea by installing at the base of the tower a smooth hinge, a rotational spring 2

(of stiffness k) and a rotational variable damper whose damping constant c can be driven in real time by a control algorithm. The same result can be practically produced by mounting two vertical linear springs (ks) placed at a certain distance (ls) from the hinge and two vertical variable dampers (cd) at a distance ld from the central hinge (Fig. 1(c)). SA magnetorheological (MR) dampers were considered as smart devices within the proposed control system: by varying the MR dampers mechanical properties according to a given control logic, the base control system is able to realize a real time regulation of the system s stiffness. When a low value is imposed to the base damping, the base restraint is less stiff, so that the structure is able to rela by converting its potential energy into kinetic energy, and the bending moment at the base is reduced. It was epected that a direct consequence of controlling the demand of base bending stress can be an increase of total top displacement demand. Therefore, the SA base control system was thought to reduce base stress, by restraining the increase of top displacements within certain limits to control second order effects. The springs have also the role to induce the recentering of the tower to the initial position at the end of a severe wind-induced ecitation. m m m k, c T T k T, ct k T, ct c ( t) k k s cd ( t) cd ( t) k s ( a) ( b) Figure 1 - Basic idea of SA rocking control of a wind turbine. ls ( c) ld Predefined control algorithm for such specific application cannot be found in literature, where a significant number of SA controllers, still for MR dampers, are formulated to protect structures against strong earthquakes rather than wind. Therefore, a specific control algorithm, based on a simple, physical approach, has been formulated by the authors [7, 8] to instantaneously decide the system s base restraint configuration. It deals with a bang-bang controller, switching back and forth from an OFF state (intensity of current i = imin, i.e. the minimum current set to be given to the dampers) to an ON state (i = ima, i.e. the maimum assumed value for the current) according to a logic aiming to control both the base stress and the top displacement. Practically, the objective of the control algorithm was to achieve a trade-off between two contradictory objectives: a limit value for the base stress lim and a limit value for the top displacement lim. The following instructions are applied: a) b) c) d) if if if if t lim t lim and t lim t lim and t lim and t t t and t and t t lim lim where (t), (t) and ẋ(t) are respectively the value of stress at the base, top displacement and top velocity at the instant of time t. In other words, the controller keeps stiffer the base restraint (ON) until the stress eceeds the limit value lim, whereas relaes it (OFF) when this limit is overpassed. 3 ON OFF ON OFF (1)

and the displacement falls within the limit of acceptability lim. When both stress and displacement are beyond the respective threshold values, the controller switches ON the dampers if the displacement is going towards a larger value, so trying to damp or even invert the displacement s trend; otherwise it switches OFF the MR devices to make them collaborating to both stress and displacement reduction. By considering the physical basis of the control logic, it is epected that, when a large value of lim is adopted (i.e. less but not so far from the maimum value of base stress in fied base conditions), a moderate reduction of base stress is achievable, while top displacement demand may increase significantly. This is caused by a limited number of SA operations, so that the dissipation phases are concentrated in much small intervals of time, not effective in reducing significantly the response in displacement. In other words, the instantaneous relaing of the base restraint is able to limit the top displacement response, only when a significant dissipation of energy occurs. Vice versa, when smaller values of lim are used, the system benefits from a greater dissipation of energy and, depending also on the assumed value for lim, may behave better from both points of view, i.e. base stress and top displacement. The application of the proposed control algorithm requires the definition of rational criteria to optimally calibrate the parameters involved in (lim and lim). A large numerical campaign has been performed with reference to a case study real structure, aiming to investigate the role each parameter has regarding the structural response, and to learn a possible procedure to calibrate them aiming at achieving the maimum reduction of base stress and top displacement demands. 3 CALIBRATION OF CONTROLLER FOR A REAL STRUCTURE A calibration procedure is proposed in the following, in order to provide the optimal choice of values to be assigned to the parameters (lim and lim) involved in the control algorithm. The first step is developing a finite element model of the structure to be eamined, able to simulate both fied base (FB) and SA controlled configurations. With reference to a given wind load, the structural response in the FB case has to be computed. Then, a wide number of SA numerical simulations has to be designed and performed. The analysis of results using a constrained optimization approach allows to single out the optimal configuration of the controller able to achieve the maimum reduction of base stress while not producing increasing of top displacement with respect to the FB case. An application of this procedure is showed in the following for a specific case study. 3.1 Case study: a real 3MW wind turbine. The case study structure is a prototype real wind turbine. It is a 3 MW wind turbine with horizontal power transmission ale, 12.4 m tall, with a variable hollow circular cross section whose eternal diameter is variable from 2.3 m (top) to 4.15 m (bottom), and whose thickness is variable from 14 mm (top) to 4 mm (bottom). A lumped mass of 111 t is placed at the top of the tower. The base of the prototype structure is highly stiff and is supported in the middle by a cylindrical steel hinge. On both sides of the base, one cylindrical spring (1417 kn/m stiff) and one SA MR damper are installed. The assembly elastic springs + SA MR dampers, whose elements are placed in parallel at the base of the tower, just represents the smart base restraint proposed by the authors to control the dynamic behaviour of the structure. An etreme operating gust loading has been considered in the following as reference wind action: a sharp increase, then decrease in wind speed within a short period of time. Chen and Georgakis [1] defined an equivalent base acceleration time history (Fig. 2), that is the base input that would provide the same top mass response of the real fied base structure subjected to the wind action. 4

acceleration (m/s 2 ).8.6.4.2. -.2 -.4 -.6 -.8 1 2 3 4 5 6 Figure 2 - Equivalent base acceleration time history for the wind load case. 3.2 Numerical model A finite element model has been developed in Matlab environment to simulate the dynamic behavior of the case study real structure. It consists in 37 elements: 36 elements simulate the tower with variable hollow circular cross section (along the height, a variable diameter from 4.15 m to 2.3 m and a variable thickness from 4 mm to 14 mm), while the last element (37 th ) is more rigid (a double second moment of inertia is assigned) and represents the connection of the top of the tower to the barycenter of the nacelle. A constant diameter and thickness is assigned to each element. The rotor and the aerodynamics have not been included in the model due to its compleity, and the nacelle and its internal components are represented by a concentrated mass at the top of the structure, with no dynamic interaction considered. Such mass is added in the global mass matri at the translational degree of freedom at the top of the tower. The base system has been modeled as in Fig. 3, that is by a rotational spring kspring and a Mawell element (representing the MR dampers) working in parallel. The value for kspring (4.82e8 Nm/rad) has been easily derived known the stiffness of the two linear springs and their distance from the center of rotation (hinge). The Mawell element, as known, consists of a spring kmawell and a linear viscous damper cmawell in series. The controllable part of this device is represented by the constant cmawell, while kmawell has been simply assumed high enough (1.e11 Nm/rad) so as to behave like a rigid link. Two different values of cmawell (con, coff) have been determined so as to reproduce the dissipative capability of MR dampers respectively in the ON and OFF states. These two opposite configurations of the MR dampers are assumed to be those corresponding to two feeding currents i=imin and i=ima considered for the MR dampers. Suitable numerical models for such kind of devices are described in [9]. The values of con=1e12 Nms/rad (i=ima=1 A) and coff=2e8 Nms/rad (i=imin=) have been etrapolated on the basis of preliminary eperimental tests carried out on a scaled structural model of the eamined case study real turbine tower [8]. 5

k Mawell c Mawell k spring Figure 3 - Representation of the base restraint within the FE model of the SA controlled structure. A customized integration procedure has been formulated for the analyses: the structure is analyzed by using the Newmark method, while the Mawell support is analyzed separately feeding a force to the tower. The integration procedure is based on forward and backward differences, which yield to the base bending moment. In order to simulate the time delay of the real mechanical response of the MR dampers, each ON/OFF and OFF/ON switch is imposed to occur not instantaneously but in ten milliseconds by following a linear law. 3.3 Numerical investigation A number of 152 numerical tests have been performed with reference to the above FEM model in SA configuration. This corresponds to the total number of different combinations of stress (lim) and displacement (lim) limits that have been tested, chosen within the ranges [1, 8] MPa and [5, 12] mm with a step of, respectively, 1 MPa and 5 mm, ecept for the step of 1 mm from 7 mm to 12 mm. In order to compare the effectiveness of the SA control strategy for each of the above settings of the controller, and to single out the optimal calibration of the latter, the structural response has been summarized by computing the following defined performance indices: - ratio of maimum bending stress ma to limit value lim assumed to calibrate the controller (ma / lim); - ratio of maimum bending stress in SA to fied base (FB) conditions (ma / ma,fb); - ratio of maimum top displacement in SA to FB conditions (ma / ma,fb). Then, to better interpret the results, the following two additional information have been considered: - total amount of time in which the MR damper has been switched off by the controller (toff); - total number of switches (onoff and vice versa) commanded to the variable device (nsw). The ratio ma / lim is assumed so as to check if and how the controller has been able to limit the bending stress to the desired value lim, while the ratio ma / lim has not been assumed as parameter for comparison because it is not significant to the same etent given that lim has a reduced impact on the controller operation. The indices ma / ma,fb and ma / ma,fb epress the effectiveness of the controller in reducing the structural response with respect to the FB conditions. Values less than one are desired, in fact they reflect the main purpose of the control strategy. The indices toff and nsw give a quantitative idea about the activity of the MR damper during each test. When the smart device is set to ON, it is not very far from acting as a rigid link. Therefore, the above toff gives also a measure of the overall duration of the dissipation phase. 6

4 DISCUSSION OF THE RESULTS The constrained optimization of the controller is performed according to the condition in Eq. (2), that is, aiming to achieve the highest reduction of the base stress and, at the same time, a top displacement no higher than that in uncontrolled FB condition. ma ma,fb min subject to 1 (2) ma ma, FB Analyzing diagrams (a) to (d) in Fig. 4, it is possible to state that the SA control of the case study wind turbine is almost always beneficial in terms of reduction of base stress with respect to the fied base scheme. Considered the whole set of eamined cases, the maimum base stress reduction results to be around 73%, and corresponds to the case (lim, lim)=(1 MPa, 9 mm). The maimum top displacement reduction is about 43%, for (lim, lim)=(2 MPa, 5 mm). The worst case, i.e. that corresponding to the maimum amplification of (+3%) with respect to the FB case is (lim, lim)=(3 MPa, 12 mm). A higher number of operations of the SA controller can be epected for smaller values of lim, as shown in Fig. 4(f). Then, Fig. 4(e) highlights that maimum base stress ma is practically always included in the interval [lim, 2lim], with the eception of those cases where both very small values are fied both for lim and lim. The response ma is roughly monotonic with varying the assumed value for lim: the smaller the assumed value for lim, the smaller the recorded value of ma, the value of the latter also being dependent on the value set for lim (Fig. 4(a)). The response ma doesn t show the same trend (Fig. 4(b)), because the response fluctuates around the value (117 mm) registered for the FB case. It results that, when values of lim greater than 6 MPa are adopted (i.e. roughly greater than.75ma,fb), there is no chance to reduce displacements in respect to the FB case. The reason is related to the fact that in such cases the SA operations are really limited, as from Fig. 4(f) clearly emerges. Therefore, the dissipation phases are concentrated in much small intervals of time, not effective in reducing significantly the response in displacement. Vice versa, when smaller values of lim are used (i.e. less than 6 MPa), the reduction or amplification of ma in respect to ma,fb also depends on the assumed value for lim. It seems that selecting values for lim less than.5ma,fb leads always to good results in terms of displacement response. According to the criterion defined in the condition above, the optimal configuration of the control algorithm corresponds to the case (lim, lim)=(1 MPa, 9 mm) since it leads to the maimum response reduction (about 73%) in base stress, and also to a reduction (about 34%) of displacement in respect to the FB case. Therefore, preliminary conclusions about a possible way to optimally calibrate the controller could be drawn suggesting to assume, for lim and lim, values respectively around.1.12ma,fb and.8 1.ma,FB. Moderately low values of lim (3-5% of ma,fb) leaded to increased top displacements, even higher than the reference value ma,fb. A trend reversal for values of lim even more smaller (1-2% of ma,fb) has been registered, leading them to significant reduction of both base stress and top displacement, as said above, due to the higher number of operations of the controller and, consequently, to the sharp increase of dissipated energy due to the larger rocking of the base. In order to directly evaluate the influence of the P- effect on the structural response, gravity load has been also considered during the non-linear analyses, without causing a significant increase to computational time. Fig. 5 shows the influence of the P- effect in the FB condition: if it is neglected, the numerical analysis is not able to capture an amplification up to 9% in top displacements and up to 14% in base stresses. But, this influence on top displacements and base stresses is contrasted by the operation of the SA controller, as clearly made in evidence by Fig. 6: 7

t off [s] n sw [-] ma (MPa) ma (mm) the introduction of the P- effect in the non-linear analyses produces an amplification of only 1% in top displacements while even a reduction of 6% is detected in base stresses. Top displacements of Fig. 6 show a residual displacement due to the intrinsic operation decided by the adopted control algorithm. This behavior could represent a problem for longer wind load cases. Therefore, the above results cannot be directly generalized, since clearly dependent on the specific wind load case and turbine model assumed for the analyses. Future further research about this topic will have to consider a larger set of wind load cases, to understand if and how the optimal calibration of the control algorithm depends on the characteristics of the eternal action. 12 1 (a) 16 14 (b) 8 ma,fb =82 MPa 12 1 ma,fb =117 mm 6 8 =5 mm =1 mm lim =5 mm =1 mm =15 mm =2 mm =15 mm lim =2 mm lim =1 MPa lim =25 mm =25 mm =3 mm 6 =3 mm lim =9 mm lim =2 MPa 4 lim =35 mm =4 mm =35 mm =4 mm =5 mm =45 mm =5 mm =45 mm =5 mm 4 =55 mm =6 mm =55 mm =6 mm =65 mm =7 mm 2 =65 mm =7 mm lim =1 MPa =8 mm =9 mm 2 lim =8 mm =9 mm =9 mm lim =1 mm =11 mm =1 mm =11 mm =12 mm =12 mm 2 4 6 8 2 4 6 8 lim (MPa) lim (MPa) 1.4 (c) 1.4 (d) 1.2 1.2 1. 1. ma / ma_fb.8.8 =5 mm =1 mm lim =5 mm =1 mm =15 mm.6 =2 mm lim =15 mm =2 mm.6 lim =1 MPa =25 mm =25 mm =3 mm =3 mm lim =9 mm lim =35 mm =4 mm lim =35 mm =4 mm.4 =45 mm.4 lim =45 mm =5 mm =5 mm =55 mm =6 mm lim =55 mm =6 mm.2 lim =1 MPa lim =65 mm =65 mm =7 mm lim =7 mm.2 =9 mm =8 mm =8 mm =9 mm lim =9 mm =1 mm =1 mm =11 mm lim =11 mm =12 mm. =12 mm. 2 4 6 8 2 4 6 8 lim (MPa) lim (MPa) ma / ma, FB ma / lim 8 6 4 (e) =5 mm =1 mm =15 mm =2 mm =25 mm =3 mm =35 mm =4 mm =45 mm =5 mm =55 mm =6 mm =65 mm =7 mm =8 mm =9 mm =1 mm =11 mm =12 mm 2.4 2. 1.6 1.2 (f) time off number of switches 36 3 24 18.8 12 2 lim =1 MPa =9 mm.4 6. 2 4 6 8 2 4 6 8 1 lim (MPa) lim (MPa) Figure 4 - Performance indices for the 1 configurations of the SA controller. 8

SA - command voltage (V) SA with P-D - command voltage (V) top displacement (mm) base stress (MPa) top displacement (mm) base stress (MPa) 14 15 Fied base Fied base with P-D 1 Fied base Fied base with P-D 7 5 35-35 -7-5 -15-14 15 3 45-1 15 3 45 Figure 5 - Base stress and top displacement response time-histories: comparison relative to the FB configuration, with vs. without P- effect 14 1 6 Fied base Fied base with P-D Semi-active Semi-active with P-D 1 75 5 Fied base Fied base with P-D Semi-active Semi-active with P-D 2-2 25-25 -6-5 -1-75 -14 15 3 45 6 5 Semi-active Semi-active with P-D -1 15 3 45 3 2 4 1 3 2-1 1-2 -3 15 3 45 Figure 6 - Base stress, top displacement and command voltage time-histories: comparison relative to the selected case ( lim, )=(1 MPa, 9 mm), with vs. without P- effect 5 CONCLUSIONS The effectiveness of a smart base restraint for wind turbines to reduce structural demand under etreme wind loads has been investigated. The technique is based on the dissipation of energy associated to the rocking of the base, where variable dampers driven by a specific control algorithm are installed. This has been eplored with reference to a commercial 3 MW wind turbine, 12.5 m tall and a realistic wind load simulating the effect of an etreme operating gust. Several configurations of the controller have been assessed in terms of reduction of demand of base stress and of top displacement. The main conclusions, some surprising, can be summarized as follows: 9

relaing several times the restraint at the base of the tower, while leading to the reduction of the stresses at the base, does not necessarily imply an increase of the top displacement with respect to the fied base condition; suitably calibrating the control algorithm, it is even possible to achieve at the same time (small) reductions of top displacement and (significant) reductions of bending stress at the base; while the p-delta effect results to be detrimental as epected for a conventional, fied base structural scheme, it produces negligible effects (in some cases even beneficial) when the SA control scheme is adopted. Future developments of this idea should be addressed to: the involvement of more wind loads, different one each other for intensity, duration, frequency content, so as to understand if an unique optimal configuration of the controller can be defined for all of them; understand whether and how to reduce the residual top displacement due to the possible incremental base rotation that may happen during a wind load history, especially when it is long lasting. In other words, a possible way to give a recentering action (or actions) at the end of (or periodically during) the severe load history should be evaluated. REFERENCES [1] Chen, J. & Georgakis, C.T. Tuned rolling-ball dampers for vibration control in wind turbines, Journal of Sound and Vibration, 332, 5271-5282, 213, d.doi.org/1.116/j.jsv.213.5.19. [2] Chen, J. & Georgakis, C.T. Spherical tuned liquid damper for vibration control in wind turbines, Journal of Vibration and Control, 215; 21(1), 1875-1885, doi: 1.1177/177546313495911. [3] Karimi, H.R., Zapateiro, M. & Luo, N. Semiactive vibration control of offshore wind turbine towers with tuned liquid column dampers using H output feedback control, Proceedings of the IEEE International Conference on Control Applications, Yokohama, Japan, 21. [4] Luo, N., Bottasso, C.L., Karimi, H.R. & Zapateiro, M. Semiactive control for floating offshore wind turbines subject to aero-hydro dynamic loads, Proceedings of the International Conference on Renewable Energies and Power Quality, Las Palmas de Gran Canaria, Spain, 211. [5] Lackner, M. & Rotea, M. Structural control of floating wind turbines, Mechatronics, 211; 21, 74-719, doi:1.116/j.mechatronics.21.11.7. [6] Kirkegaard, P.H., Nielsen, S.R.K., Poulsen, B.L., Andersen, J., Pedersen, L.H. & Pedersen, B.J. Semi-active vibration control of a wind turbine tower using an MR damper, H. Grundmann, G.I. Schuëller, Rotterdam: Balkema Publishers, A.A. / Taylor & Francis The Netherlands, 1575-158, 22. [7] Caterino, N., Georgakis, C.T., Trinchillo, F. & Occhiuzzi, A. A semi-active control system for wind turbines, In: N. Luo, Y. Vidal, L. Acho, Wind Turbine Control and Monitoring, Springer International Publishing, 375-47, Advances in Industrial Control, 214, doi: 1.17/978-3- 319-8413-8_13. [8] Caterino, N. Semi-active control of a wind turbine via magnetorheological dampers, Journal of Sound and Vibration, 215; 345, 1-17, doi:1.116/j.jsv.215.1.22. [9] Caterino, N., Spizzuoco, M. & Occhiuzzi, A. Understanding and modelling the physical behaviour of magnetorheological dampers for seismic structural control, Smart Material and Structures, 211; 2(6), doi:1.188/964-1726/2/6/6513. 1