Wiper Gold Edition. Premium Wipe Test Counter. Setting the bar higher

Similar documents
Wiper Gold Edition. Premium Wipe Test Counter. Setting the bar higher

The Multi-Wiper HE. High Energy Nuclear Medicine Well Counter. The first multi-well counters designed specifically for Nuclear Medicine!

Research Gamma Counter

1 of :32

CapeSym, Inc. Radiation Detection Solutions

SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION

LS6500 Scintillation Counting Systems

Alpha spectrometry systems. A users perspective. George Ham. 26 th May Date Month Year

FoodScreen Radiological Food Screening System

Quality Assurance. Purity control. Polycrystalline Ingots

ß + RADIATION. Choose your application of. chromatography controlled. chemical purity TLC PET GABI. PET GABI 2x2 Nal (Tl) 0 1V output.

4- Locate the channel number of the peak centroid with the software cursor and note the corresponding energy. Record these values.

The Best Gamma-Ray Detector

Characterizing, Simulating, and Eliminating Vibration Induced Counts in Measurement While Drilling Gamma Ray Detectors. authors

28th Seismic Research Review: Ground-Based Nuclear Explosion Monitoring Technologies DESIGN OF A PHOSWICH WELL DETECTOR FOR RADIOXENON MONITORING

Sample Spectroscopy System Hardware

1/5 Specifications Hidex 300 SLL automatic TDCR liquid scintillation counter

Scintillation Detector

Detection and measurement of gamma-radiation by gammaspectroscopy

MEDICAL EQUIPMENT: NUCLEAR MEDICINE. Prof. Yasser Mostafa Kadah

"Neutron Flux Distribution"

Working Copy. P /ru /,6. 8-tt tt. EffectiveDate: I ^, Operation and Calibration of the Tri-Carb Liquid Sclntillation Counter QAM-RI.106.

List of Nuclear Medicine Radionuclides. Nuclear Medicine Imaging Systems: The Scintillation Camera. Crystal and light guide

V. 3. Development of an Accelerator Beam Loss Monitor Using an Optical Fiber

Lab NUC. Determination of Half-Life with a Geiger-Müller Counter

QuantumMCA QuantumNaI QuantumGe QuantumGold

PYCKO SCIENTIFIC LIMITED

An ultra-sensitive, versatile, and affordable single tube luminometer for Life Science Research.

ɣ-radiochromatography

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

Shielded NaI(Tl) γ-ray Spectrometer with High-Precision Spectrum Analysis

Radiation Detection and Measurement

Gamma Spectroscopy. References: Objectives:

Unit 2. Instrumentation. Experts Teaching from Practical Experience

Compton suppression spectrometry

2100TR Liquid Scintillation Counter

General Overview of Radiation Detection and Equipment

IdentiFINDER Digital Hand Held Spectrometer & Dose Rate Meter for Portable Applications

Design and production of Scintillation Detectors

ISOCS / LabSOCS. Calibration software for Gamma Spectroscopy

Radiation Detection. 15 th Annual OSC Readiness Training Program.

Calibration & Use of a Capintec CAPTUS 3000 Portable Thyroid Uptake System for Iodine-125 Bioassay Measurements Todd W.

ORTEC Experiment 24. Measurements in Health Physics. Equipment Required

GAMMA RAY SPECTROSCOPY

Gamma Ray Spectroscopy

Alpha-Energies of different sources with Multi Channel Analyzer

Chapter Seven (Nuclear Detectors)

Copyright 2008, University of Chicago, Department of Physics. Experiment VI. Gamma Ray Spectroscopy

The Mössbauer Effect

CHEMISTRY 170. Radioisotopes

Radioactivity. (b) Fig shows two samples of the same radioactive substance. The substance emits β-particles. Fig. 12.1

Dependence Of Gamma Ray Attenuation On Concentration Of Manganese (II) Chloride Solution

Gamma ray coincidence and angular correlation

arxiv: v2 [physics.ins-det] 8 Feb 2013

Alpha-energies of different sources with Multi Channel Analyzer (Item No.: P )

Scintillation Detectors

SCINTILLATION DETECTORS AND PM TUBES

Scintillation Detectors

Examples for experiments that can be done at the T9 beam line

Renewed whole-body counting chamber in STUK

Calibration of A Small Anode Germanium Well Detector

Determination of the boron content in polyethylene samples using the reactor Orphée

RESULTS YOU CAN COUNT ON


CHEMISTRY 130 General Chemistry I. Radioisotopes

Introduction to gamma spectroscopy on a budget. Daniel Emes SA Radiation

Validation of detection efficiency of alpha particles in commercial liquid scintillation counters

NUCL 3000/5030 Laboratory 2 Fall 2013

He-3 Neutron Detectors

Calibration of the Modular Neutron Array (MoNA)

ORTEC AN34 Experiment 10 Compton Scattering

RESPONSE OF A NAI(TL) SCINTILLATION DETECTOR IN A WIDE TEMPERATURE INTERVAL

Figure 1. Decay Scheme for 60Co

DIGITAL PULSE SHAPE ANALYSIS WITH PHOSWICH DETECTORS TO SIMPLIFY COINCIDENCE MEASUREMENTS OF RADIOACTIVE XENON

Gamma and X-Ray Detection

Jazan University College of Science Physics Department. Lab Manual. Nuclear Physics (2) 462 Phys. 8 th Level. Academic Year: 1439/1440

PHY 192 Compton Effect Spring

THE MÖSSBAUER EFFECT

arxiv: v1 [physics.ins-det] 29 Jun 2011

REX Evaluation Guide. American Micro Detection Systems Inc March Lane, Suite 200 Stockton, CA 95219

Gamma-ray spectroscopy with the scintillator/photomultiplierand with the high purity Ge detector: Compton scattering, photoeffect, and pair production

RADEAGLET. Lightweight Handheld Radioisotope Identification Device

WM2013 Conference, February 24 28, 2013, Phoenix, Arizona, USA

What is scintigraphy? The process of obtaining an image or series of sequential images of the distribution of a radionuclide in tissues, organs, or

Portable gamma and thermal neutron detector using 6 LiI(Eu) crystals

A Study of Radioactivity and Determination of Half-Life

Applied Nuclear Science Educational, Training & Simulation Systems

Basic hands-on gamma calibration for low activity environmental levels

A Prototype of LaBr3:Ce in situ Gamma-Ray Spectrometer for Marine Environmental Monitoring

Experiment Radioactive Decay of 220 Rn and 232 Th Physics 2150 Experiment No. 10 University of Colorado

Outline Chapter 14 Nuclear Medicine

Gamma-ray spectroscopy with the scintillator/photomultiplierand with the high purity Ge detector: Compton scattering, photoeffect, and pair production

Chapter 11: Neutrons detectors

ICP-MS. High Resolution ICP-MS.

Pulse height non-linearity in LaBr 3 :Ce crystal for gamma ray spectrometry and imaging

S8 TIGER Series 2 for ASTM D 6443

SCI-O11. Design of a Compton Spectrometer Experiment for Studying Electron Response of a Scintillator

BWXT Y-12 Y-12. A BWXT/Bechtel Enterprise SMALL, PORTABLE, LIGHTWEIGHT DT NEUTRON GENERATOR FOR USE WITH NMIS

Hidex 300 SL Automatic TDCR Liquid Scintillation Counter

An Improved U-Pu System for Field Pu Measurements

Transcription:

Wiper Gold Edition Premium Wipe Test Counter This product is available through: JRT Associates 5 Nepperhan Avenue, Suite 2B Elmsford, NY 10523 800-221-0111 Setting the bar higher

Software - Simplicity, Re-defined Load your wipe into the well and press the button. Your wipe is counted and automatically converted to DPM. If the wipe is above trigger, it is flagged and the contaminating isotope identified - that s all there is to it. Your Time is Valuable Answer a few questions, and we will pre-program the instrument - customized for your department. Your Wiper Gold then arrives ready to use, just plug it in and go...

The Detector Radiation is emitted 360 degrees, yet some manufacturers don t seem to understand that. Minimizing crystal mass below the well has a detrimental effect on counting efficiency - especially at higher energies. We designed it better Well By increasing the crystal mass and thickness below the well (up to 400%), the Wiper Gold captures more counts, making it ideal for 511 PET isotopes. Our design results in 40% more crystal mass than some other well counters. NaI(tl)! crystal PMT The Wiper Gold s crystal design: more crystal mass where it counts - below the sample With.75 inches of lead shielding (50% more than other wipe counters), lower background readings are achieved without adding external lead. More shielding + greater crystal mass = Lower MDA s, 80% Co57 efficiency and better results with isotopes like F18.

Hardware One of the keys to making wipe counting fast, easy and accurate is providing useful isotope identification when a hot wipe is found. A low resolution analyzer hampers performance and can result in false readings and mis-identified contaminants. Other counters use a low resolution analyzer. It s like taking a picture with a cheap camera. Wipe counters with 64 or even 256 channels just don t have the resolution needed for isotope identification. With such low resolution, you may not be able to distinguish Tc99m from Co57. With the Wiper Gold s analyzer, results are crystal clear - like a quality high resolution camera. The Wiper Gold provides superior resolution with 4096 channels. No ifs no buts - just accurate, unmistakeable isotope ID - every time. The answer is clear. Why would you pay more for less?

Say Goodbye to all those Calibration Sources With our proprietary AutoSpect feature, you no longer need to purchase expensive isotope standards for multiple energies. Our unique approach allows the user to count any gamma emitting isotope* and get accurate DPM results automatically. No fudge factors needed, no guess work necessary. Just accurate DPM results automatically and effortlessly. With the Wiper Gold there is no need for multiple sources. * The Wiper Gold can measure any isotope that has gamma or x-ray emissions up to 1 MEV.

For The Physicist Especially for the Physicist, the RSO and Power users: Improved high activity counting - samples over 300,000 CPS may be counted with exceptional linearity. Automatic sample decay correction - with automatic decay correction samples at the end of a batch are as statistically accurate as samples at the beginning of the batch. Advanced MCA Features - Zoom, ROI, PHA, Peak Search, Marking, etc. A full featured MCA, without complicating daily use. Reverse/Future decay correction - decay correct a sample to a previous point in time or a future point in time. Using reverse decay correction, the user can determine what the activity would have been two days, or even two weeks earlier. Sample volume correction - corrects for geometry differences when samples with varying physical volumes need to be counted and compared.

Specifications Detector: NaI(tl) drilled well crystal coupled to a high gain, linearity-selected photomultiplier tube. Assembly is hermetically sealed in aluminum housing with an internal mu-metal magnetic shield. Asymmetrical crystal shape provides additional crystal mass below the well for greater efficiency with higher energy isotopes such as F18. Well Dimension: 1.25 inches deep x.669 inches diameter. Shielding: 0.75 inches of virgin lead, extending more than 3.5 inches beyond the bottom of the crystal. High Voltage: Custom engineered Croft-Walton style circuitry with multi-stage gain adjust for ultra-precise software control of calibration. Analyzer: High speed 4096 channel analyzer (12 bit) with automatic dead time correction, pole zero correction and baseline restoration. Integral linearity better than 0.5%. Count rate capability 300,000 CPS. Printer: Optional compact 80 column thermal printer. Power: 100-240 VAC (Universal, automatically adjusting power supply), 50-60Hz, less than 30 watt consumption. Dimensions/weight: 10.5 W x 8.5 D x 4.75:H (base); 6 D x 10 H (detector). Thirty two pounds.