This article appeared in a journal published by Elsevier. The attached copy is furnished to the author for internal non-commercial research and

Similar documents
ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

RESPONSE FUNCTION STUDY FOR ENERGY TO LIGHT CONVERSION IN ORGANIC LIQUID SCINTILLATORS

in Cross-Section Data

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

FAST NEUTRON MULTIPLICITY COUNTER

MCNP6 simulation validation of fast neutron coincidence detection system for nuclear security and safeguards applications

Correlations in Prompt Neutrons and Gamma Rays from Fission

Detectors, Electronics, and Algorithms for Nuclear Nonproliferation, Safeguards, and Homeland Security Applications

CALIBRATION OF SCINTILLATION DETECTORS USING A DT GENERATOR Jarrod D. Edwards, Sara A. Pozzi, and John T. Mihalczo

Fast Neutron Multiplicity Counter: Development of an active-mode counter UM-INL Collaboration

Correlations in Prompt Neutrons and Gamma Rays from Fission

Cf-252 spontaneous fission prompt neutron and photon correlations

Digital simulation of neutron and gamma measurement devices

Correlation in Spontaneous Fission of Cf252

Time Correlation Measurements of Heavily Shielded Uranium Metal. Oak Ridge National Laboratory, 1 Bethel Valley Road, Oak Ridge, TN 37831

Neutron and Gamma Ray Imaging for Nuclear Materials Identification

Louis Baum University of Michigan, REU Student Summer UM Nuclear Sciences Group

Monte Carlo Characterization of a Pulsed Laser-Wakefield Driven Monochromatic X-Ray Source

FRAM V5.2. Plutonium and Uranium Isotopic Analysis Software

Hands on LUNA: Detector Simulations with Geant4

The Detection Statistics of Neutrons and Photons Emitted from a Fissile Sample

STUDY ON THE ENERGY RESPONSE OF PLASTIC SCINTILLATION DETECTOR TO MEV NEUTRONS ABSTRACT

Research in NDA Techniques for Waste Characterization at the JRC

Measurements of the Prompt Fission Neutron Spectrum at LANSCE: The Chi-Nu Experiment

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

Consortium for Verification Technology

The Statistics of the Number of Neutron Collisions Prior to Absorption

Application of a Laser-Wakefield Driven Monochromatic Photon Source to Nuclear Resonance Fluorescence

This article appeared in a journal published by Elsevier. The attached copy is furnished to the author for internal non-commercial research and

SNM detection by means of thermal neutron interrogation and a liquid scintillation detector

arxiv: v1 [physics.ins-det] 29 Jun 2011

Applied Radiation and Isotopes

Distinguishing fissions of 232 Th, 237 Np and 238 U with beta-delayed gamma rays

Special Nuclear Material Detection Studies With The SMANDRA Mobile System

Alpha-Gamma discrimination by Pulse Shape in LaBr 3 :Ce and LaCl 3 :Ce

Measurement of nuclear recoil responses of NaI(Tl) crystal for dark matter search

arxiv: v1 [physics.ins-det] 16 May 2017

Nuclear Reactions A Z. Radioactivity, Spontaneous Decay: Nuclear Reaction, Induced Process: x + X Y + y + Q Q > 0. Exothermic Endothermic

This article appeared in a journal published by Elsevier. The attached copy is furnished to the author for internal non-commercial research and

Quartz-Crystal Spectrometer for the Analysis of Plutonium K X-Rays

Radiation Detection and Measurement

Arjan Plompen. Measurements of sodium inelastic scattering and deuterium elastic scattering

Improving neutron detection efficiency by using passive converters

RADIATION DETECTION AND MEASUREMENT

Recent Activities on Neutron Standardization at the Electrotechnical Laboratory

Radiation Detection and Measurement

FAST TIME-CORRELATION MEASUREMENTS IN NUCLEAR SAFEGUARDS

This article appeared in a journal published by Elsevier. The attached copy is furnished to the author for internal non-commercial research and

This article appeared in a journal published by Elsevier. The attached copy is furnished to the author for internal non-commercial research and

Characterization of the 3 MeV Neutron Field for the Monoenergetic Fast Neutron Fluence Standard at the National Metrology Institute of Japan

Update on Calibration Studies of the Canadian High-Energy Neutron Spectrometry System (CHENSS)

Development and test of the high-precision -beam monitor at the ESFRI facility ELI-NP

Chinese Physics C. Study of n-γ discrimination in low energy range (above 40. kevee) by charge comparison method with a BC501A liquid

MCNPX PoliMi Variance Reduction Techniques for Simulating Neutron Scintillation Detector Response

This article appeared in a journal published by Elsevier. The attached copy is furnished to the author for internal non-commercial research and

Shielded Scintillator for Neutron Characterization

Radiation Detection and Measurement

HIGH-THROUGHPUT RADIATION DETECTION SYSTEMS

M.Cagnazzo Atominstitut, Vienna University of Technology Stadionallee 2, 1020 Wien, Austria

A POSITION SENSITIVE ALPHA PARTICLE DETECTOR BASED ON A LYSO CRYSTAL AND A MICRO-PIXEL AVALANCHE PHOTODIODE

A Radiation Monitoring System With Capability of Gamma Imaging and Estimation of Exposure Dose Rate

Problem P7. Stéphanie Ménard. Dosimetry Department Fontenay-aux FRANCE IRSN QUADOS IRSN

Measurement of high energy gamma rays with large volume LaBr 3 :Ce scintillators

CHARACTERISTICS OF LIGHT CHARGED PARTICLE EMISSION IN THE TERNARY FISSION OF 250 CF AND 252 CF AT DIFFERENT EXCITATION ENERGIES

Characterization and Monte Carlo simulations for a CLYC detector

Neutron Dose near Spent Nuclear Fuel and HAW after the 2007 ICRP Recommendations

Response function measurements of an NE102A organic scintillator using an 241 Am-Be source

Pulsed Neutron Interrogation Test Assembly - PUNITA

Measurement of prompt fission γ-ray spectra in fast neutroninduced

Introduction to Radiological Sciences Neutron Detectors. Theory of operation. Types of detectors Source calibration Survey for Dose

A Comparison between Channel Selections in Heavy Ion Reactions

Bonner Sphere Spectrometer. Cruzate, J.A.; Carelli, J.L. and Gregori, B.N.

Simple Experimental Design for Calculation of Neutron Removal Cross Sections K. Groves 1 1) McMaster University, 1280 Main St. W, Hamilton, Canada.

Fissile material experiments at the Device Assembly Facility

DETECTORS. I. Charged Particle Detectors

Low Energy Neutron Verification in GEANT4: to 4.9.5

Development of a Dosimetric System using Spectrometric Technique suitable for Operational Radiation Dose Measurements and Evaluation

Neutron pulse height analysis (R405n)

Gamma production cross section measurements for 76Ge via (n,n'γγ) at GELINA

Preparatory experiments for cold-neutron induced fission studies at IKI

COMPARATIVE STUDY OF PIGE, PIXE AND NAA ANALYTICAL TECHNIQUES FOR THE DETERMINATION OF MINOR ELEMENTS IN STEELS

Nuclear Instruments and Methods in

Emerging Capabilities for Advanced Nuclear Safeguards Measurement Solutions

VERIFICATION OF MONTE CARLO CALCULATIONS OF THE NEUTRON FLUX IN THE CAROUSEL CHANNELS OF THE TRIGA MARK II REACTOR, LJUBLJANA

Neutron emission asymmetries from linearly polarized γ rays on nat Cd, nat Sn, and 181 Ta

This article appeared in a journal published by Elsevier. The attached copy is furnished to the author for internal non-commercial research and

Neutron Spectrometry Using a 7 Li Enriched CLYC Scintillation Detector

CCD readout of GEM-based neutron detectors

1. Introduction. persistence challenge in the field of radiation detection and, for the most part, has gone

PHYS 3650L - Modern Physics Laboratory

New Neutron-Induced Cross-Section Measurements for Weak s-process Studies

A Proposal of Nuclear Materials Detection and Inspection Systems in Heavily Shielded Suspicious Objects by Non-destructive Manner.

Computational study to enhance threat detection of radiation portal monitors:

M.J. CIESLAK, K.A.A. GAMAGE Department of Engineering, Lancaster University Lancaster, LA1 4YW United Kingdom ABSTRACT

Substance Detection using mono-energetic neutrons

He-3 Neutron Detectors

CHARACTERIZING THE DETECTOR RESPONSE AND TESTING THE PERFORMANCE OF A NEW WELL COUNTER FOR NEUTRON COINCIDENCE MEASUREMENTS OF PLUTONIUM IN RESIDUES

Verification measurements of alpha active waste


Transcription:

This article appeared in a journal published by Elsevier. The attached copy is furnished to the author for internal non-commercial research and education use, including for instruction at the authors institution and sharing with colleagues. Other uses, including reproduction and distribution, or selling or licensing copies, or posting to personal, institutional or third party websites are prohibited. In most cases authors are permitted to post their version of the article (e.g. in Word or Tex form) to their personal website or institutional repository. Authors requiring further information regarding Elsevier s archiving and manuscript policies are encouraged to visit: http://www.elsevier.com/copyright

Nuclear Instruments and Methods in Physics Research A 622 (21) 191 195 Contents lists available at ScienceDirect Nuclear Instruments and Methods in Physics Research A journal homepage: www.elsevier.com/locate/nima Neutron spectroscopy of plutonium oxide using matrix unfolding approach Tomasz Zak a, Shaun D. Clarke a,n, Mark M. Bourne a, Sara A. Pozzi a, Yunlin Xu a, Thomas J. Downar a, Paolo Peerani b a University of Michigan, Department of Nuclear Engineering and Radiological Sciences, 2328B Cooley Building, 2355 Bonisteel Blvd. Ann Arbor, MI 4819, USA b European Commission EC-JRC-IPSC, Ispra, Italy article info Article history: Received 12 March 21 Received in revised form 29 June 21 Accepted 2 July 21 Available online 15 July 21 Keywords: Plutonium oxide Neutron spectroscopy Detector response matrix abstract The knowledge of a neutron energy spectrum is extremely valuable in nuclear non-proliferation and safeguards applications. Unfortunately, conventional gas and fission-type detectors are not adapted to determine incident neutron energy. As a result, a matrix inversion technique was implemented to generate desirable and consistent neutron energy spectra from an EJ-39 liquid scintillator. To overcome the ill-posed unfolded solutions, the method of sequential least squares is reviewed briefly, and the conditions under which it is used are stated. From the analysis, unfolded energy spectra solutions of five distinct PuO 2 fuel samples and a 252 Cf source are presented and compared to the simulated unfolded and reference energy distributions. & 21 Elsevier B.V. All rights reserved. 1. Introduction The physical properties of liquid scintillators make them ideal for the measurement of fast neutrons. Liquid scintillators provide good efficiency for neutron interactions by elastic scattering collisions. Spectral averaged efficiencies vary, but are typically around 3 7%, depending on the size of the liquid cell [1]. These properties, plus the ability to discriminate neutrons from gamma rays, make liquid scintillators an excellent choice for nuclear nonproliferation and safeguards applications [2]. The knowledge of the neutron energy spectrum is extremely valuable in many applications. The energy spectrum of neutron sources for various applications varies greatly. For example, (a, n) sources used in medical or oil-well-logging applications has a very different energy spectrum that fission sources from special nuclear material (or 252 Cf). Unfortunately, commonly used neutron detectors, such as an He-3 proportional tubes, Bonner spheres, and BF 3 tubes require moderation and cannot be used to determine incident neutron energy with reasonable efficiency. As a result, a response matrix inversion algorithm was implemented to generate consistent unfolded neutron energy spectra from an EJ-39 liquid scintillator. The illposed problem is optimized through a sequential least squares method (SLSM). In a recent experiment [3], pulse-height-distributions (PHDs) of five PuO 2 samples and a 252 Cf source were measured. In this n Corresponding author. Tel.: +1 734 615 783; fax: +1 734 763 454. E-mail address: clarkesd@umich.edu (S.D. Clarke). paper, these PHDs are simulated using MCNP-PoliMi and both simulated and measured PHDs are unfolded using the SLSM. The results of both the measured and simulated data unfolding will be compared to the reference neutron energy distributions. 2. Spectrum unfolding methods 2.1. Sequential least squares approach The pulse-height distribution measured with a scintillation detector includes information on the energy spectrum of the incident neutrons. The relationship between the pulse height distribution and the energy spectrum is uniquely characterized by the detector response matrix. However, uncovering this relationship is difficult because the unfolding problem is ill-posed [4 6]. Previous attempts have shown that practical unfolded results can be obtained with an applied sequential least squares method [7]. In order to improve upon this method, the algorithm was made more versatile: now accepting a user-defined detector response matrix of any size. The detector response, incident neutron flux, and the neutron count rate are all related through the Fredholm integral of the first kind given by Z NðLÞ¼ RðE n,lþfðe n ÞdE n ð1þ where E n is the neutron energy, L is the measured light output, N(L) is the count rate density, and R(E n,l) is the detector response matrix. The problem can be solved by discretizing the above 168-92/$ - see front matter & 21 Elsevier B.V. All rights reserved. doi:1.116/j.nima.21.7.29

192 T. Zak et al. / Nuclear Instruments and Methods in Physics Research A 622 (21) 191 195 integral to its constituent components given by N i ¼ Xm j ¼ 1 R ij x j, for i ¼ 1,::,n, ð2þ where N i is the flux count rate corresponding to a certain interval of the measured light output in the i-th channel, x j is the incident neutron fluence in the j-th energy group, and R ij is the corresponding element of the response matrix. If the number of pulse height bins is the same as the number of neutron energy groups in the response matrix R, then the neutron spectrum can be obtained by solving the linear system by a matrix inversion x ¼ R 1 N ð3þ If the number of light output channels is greater than the number of neutron energy groups in the response matrix, then the system becomes over-determined and can be solved by a least squares method. Inherent statistical errors exist in both the response matrix R, and in the detector response N. Because the problem is so illposed, these errors contribute significantly to the solution and may result in negative fluxes when the least squares approach is applied. Consequently, a constrained optimization method is implemented to achieve physical unfolded solutions. The optimization problem is defined as minf ðxþ¼ 1 2 X n i ¼ 1 w i 1 @ N i Xm R ij x j A j ¼ 1 2 x i Z for ias B f1,2, :::, mg ð4þ S B refers to the set of indices for the lower bounds, which ensures that fluxes remain non-negative. 2.2. Detector response matrix A response matrix was generated and used as an input to the unfolding algorithm. The matrix was constructed by tracking particle histories, using the simulation code MCNP-PoliMi [8]. Previous work has shown that an MCNP-PoliMi can be used to accurately calculate the detector response matrix [9]. The EJ-39 liquid scintillator that was used in the measurements was simulated using an MCNP-PoliMi. Monoenergetic neutrons were simulated to produce a matrix response of scintillation light output as a function of an incident neutron energy. The final response matrix was constructed with a dimensional resolution of 21 light output bins (.5-MeVee bin width) and 15 neutron energy bins (.1-MeV bin width). The final response matrix is illustrated in Fig. 1. Each row corresponds to a single incident neutron energy and each column corresponds to the possible light output intensities for each neutron collision. As expected, higher energy neutrons can produce larger light output values. The ridge with higher intensities is formed from neutron scattering on carbon nuclei in the scintillation liquid. Carbon produces smaller light outputs per scintillation. 2.3. Energy group collapsing The unfolding algorithm is capable of collapsing adjacent neutron energy groups within the response matrix to produce an averaged energy group of larger energy bin width. The unfolding script utilizes an interpolation technique that uses a moving average to correct the energy spacing in the original input pulse height distribution. This interpolation technique reduces the statistical oscillations in the higher energy region of the PHD. This procedure decreases the total amount of obtainable unfolded data points, but generally provides a more stable unfolded solution. 3. Measurement techniques 3.1. Fissile material Measurements were performed at the JRC-Ispra, Italy on five PuO 2 samples stored in cylindrical steel containers with various heights and diameters. The canisters contained between 5 and 5 g of either high- or low-burnup PuO 2. A 25 neutrons per second certified 252 Cf source was also used in a separate measurement. Table 1 summarizes the burnup and mass of each Fig. 1. Simulated EJ-39 detector response matrix: the three dimensional matrix is shown in (a) and the two-dimensional projection is shown in (b). Each neutron energy bin corresponds to an entire column of possible light output pulse height values. The dimensions of the matrix are 15 neutron energy bins and 21 light output bins.

T. Zak et al. / Nuclear Instruments and Methods in Physics Research A 622 (21) 191 195 193 Table 1 Sample composition and burnup. Sample Net mass (g) 238 Pu (wt%) 239 Pu (wt%) 24 Pu (wt%) 241 Pu (wt%) 242 Pu (wt%) Burnup 13 49.595 1.72 58.1 24.77 9.77 5.65 High 14 98.89.2 7.96 24.58 3.29.98 Low 16 1.456 1.72 58.1 24.77 9.77 5.65 High 17 298.89.2 7.96 24.58 3.29.98 Low 19 51.984.2 7.96 24.58 3.29.98 Low Fig. 2. Fraction of spontaneous fission (s.f.) and (a, n) neutrons emitted from low- and high-burnup PuO 2 samples. 239 Pu(s.f.), 241 Pu(s.f.), 241 Pu(a, n), and 241 Pu(a, n) reactions were negligible because of low (less than.1%) intensities. PuO 2 sample [1]. Furthermore, Fig. 2 displays the fraction of total neutrons produced in the high- and low-burnup samples. In the case of the high burnup samples (samples 13 and 16), the (a, n) contribution is more significant than that of the low burnup samples (samples 14, 17, and 19). This effect results from the higher 238 Pu and 24 Pu content from longer irradiation times. The alpha reaction on oxygen produces a continuous neutron emission spectrum that has a significant peak at 2.3 MeV [11]. This peak is present in all samples, but is especially prevalent in the high burnup samples. Although the (a, n) spectrum is harder than the spontaneous fission spectrum, the fission spectrum is more dominant at energies greater than 3 MeV. Counts (arbitrary units) 1 1 1 1 2 1 3 1 4 Measured Simulated 3.2. Measurement technique 1 5 The measurement setup consisted of six EJ-39 liquid scintillation detectors (13.3 cm high and 13 cm in diameter) with Photonis XP4512B photomultiplier tubes (PMTs). The detectors were all positioned symmetrically around the sample at distance of 3 cm. Lead shielding sleeves of approximately 2.6 cm in thickness were placed around the sample to minimize the gamma ray background intensity. A detailed description of the experimental setup and procedure can be found in [12]. A CAEN V172, 12-bit, 25-MHZ digitizer was used to sample and store signal pulses directly from the detector. A detection threshold of 1-keVee (corresponding to a deposited neutron energy of approximately 6 kev) was applied to the detector. The data acquisition time was less than 5 min per sample. The counts in the four axial detectors were averaged to generate the distributions shown in the following analysis. 3.3. Pulse height distributions Measured neutron pulse height distributions for each of the PuO 2 samples and the 252 Cf source were obtained through the 1 6 Light Output (MeVee) Fig. 3. Simulated and measured neutron PHDs for sample 19 (1 s statistical error bars are shown on the simulated results). CAEN digitizer and an offline pulse shape discrimination technique was used to distinguish gamma and neutron events [13]. Simulated neutron pulse height distributions were created with the MCNP-PoliMi code. The simulated setup consisted of a detailed sample canister with the PuO 2 surrounded by the lead sleeve. For simplicity the detectors were modeled as purely active volumes. The collision information from the MCNP-PoliMi output data file was post-processed with a specifically designed FORTRAN algorithm. The algorithm produces a neutron pulse height distribution based on various physical parameters of the scintillator detector. Such parameters include the light conversion

194 T. Zak et al. / Nuclear Instruments and Methods in Physics Research A 622 (21) 191 195 efficiency and basic material characteristics of the scintillation liquid. Two pulse height distributions from sample 19 are shown in Fig. 3. The simulated and measured are normalized to their integrals. The simulated-phd obtained relatively good statistics even light outputs greater than 3 MeVee. On the other hand, the 2-V dynamic range of the CAEN digitizer limited the maximum obtainable light output of the measured sample to approximately 1.7 MeVee. 4. Spectrum unfolding results.5.45.4.35.3.25.2.15.1 4.1. Unfolded results.5 The resulting unfolded neutron energy spectra for 252 Cf and the five PuO 2 samples are shown in Figs. 4 9. Both measured and simulated unfolded energy spectra were compared to the reference energy spectrum (obtained from MCNP-PoliMi) of each.45.4.35 Fig.6. Unfolded energy spectra from the measured and simulated PHDs compared to the reference energy spectrum of the 1 g low burnup PuO 2 sample (14)..45.4.3.25.2.15.1.35.3.25.2.15.5.1 Fig. 4. Unfolded energy spectra from the measured and simulated PHDs compared to the reference energy spectrum of 252 Cf..5 Fig. 7. Unfolded energy spectra from the measured and simulated PHDs compared to the reference energy spectrum of the 1 g high burnup PuO 2 sample (16)..45.4.5.45.35.4.3.25.2.15.35.3.25.2.15.1.1.5.5 Fig. 5. Unfolded energy spectra from the measured and simulated PHDs compared to the reference energy spectrum of the 5 g high burnup PuO 2 sample (13). Fig. 8. Unfolded energy spectra from the measured and simulated PHDs compared to the reference energy spectrum of the 3 g low burnup PuO 2 sample (17).

T. Zak et al. / Nuclear Instruments and Methods in Physics Research A 622 (21) 191 195 195.5.45.4.35.3.25.2.15.1.5 sample. The measured, simulated, and reference were all normalized to their integral. The results obtained were all obtained by collapsing three adjacent neutron bins in the matrix. This improved the behavior of the unfolded spectra, but decreased the maximum obtainable energy resolution to 3 kev. Measurements of the PuO 2 samples were limited to a lower threshold bound of 1 kevee, which corresponds to approximately 6 kev. Figs. 4 9 show these results for all samples. 4.2. Simulated-PHD unfolding analysis The unfolded spectra obtained from the simulated PHDs show a very good fit to the reference spectra for all cases. Both the fission peak (approximately.8 MeV) and the (a, n) peak (approximately 2.3 MeV) were very well defined. The simulated PHDs provided enough data at large enough light outputs to allow reliable unfolding over the entire energy range. The input pulse height distribution had a detection threshold of 1 kevee, which corresponds to approximately 6-keV neutron energy deposited. Consequently, the first alpha peak at 4 kev cannot be characterized because it is below the detection threshold. The response matrix had a minimum energy of 25 kev, resulting in zero unfolded counts below this value. Tail response was also stable, although large statistical variations in the region greater than 2 MeVee (shown in Fig. 3). 4.3. Measured-PHD unfolding analysis Fig. 9. Unfolded energy spectra from the measured and simulated PHDs compared to the reference energy spectrum of the 5 g low burnup PuO 2 sample (19). The measured data was obtained with a maximum recordable light output of 1.7 MeVee (because of the 2-V dynamic range of the digitizer). This corresponds to approximately 5.5 MeV neutron energy deposited. Consequently, neutrons depositing energy greater than this are not recorded. This results in a truncated PHD range and consequently a noisier unfolded energy spectrum. Decreasing the PMT gain in the measurement or using a digitizer with a larger dynamic range would mitigate these issues. 4.4. Error analysis The inversion of the response matrix R is nontrivial. The matrix is not square and as a result the inversion problem is ill-conditioned. Statistical uncertainties in the response matrix R(E, L) or pulse height distribution N(L) from measured and simulated samples combine to give a numerically unstable solution. As a result, small changes in either the response matrix or pulse height distribution give rise to large variations in the unfolded flux. This problem is minimized by implementing a sequential least squares technique, where a firstguess solution for the unfolded spectrum is modified by repeated forward calculations of the response matrix and unfolded flux. This produces an estimate of the pulse height distribution which is iteratively updated. The statistical uncertainty in the unfolded solution is a function of the uncertainties in the detector response matrix and the measured-phd. Efforts are underway to quantify the propagation of these errors through the unfolding process. Also, large statistical variations were observed in all measured PHDs above 1 MeVee; increasing the counting time of the measurement could mitigate this effect. Furthermore, these illbehaved oscillations in the PHD are interpolated through a moving average technique within the unfolding script to produce a more physical unfolded energy spectrum. 5. Conclusion Unfolding neutron spectra can be a very useful tool for the characterization of special nuclear material. A significant advantage in this method is the ability to convert a light-output PHD into the more meaningful neutron energy spectrum. This spectrum then allows key features of the sample to be observed (for example, the characteristic spontaneous fission and alphaneutron peaks). This unfolding technique also has the capability of resolving other neutron samples, such as Pu Be, Am Li, Am Be sources, as well as mono-energetic D T and D D sources. This technique is heavily dependent on the quality and size of the measured-phd. With careful and accurate measurement techniques, it is possible to produce a reliable unfolded neutron energy spectrum that can be used for source identification. s [1] G.F. Knoll, in: Radiation Detection and Measurement, third ed., Wiley and Sons, 23, pp. 22. [2] J.L. Dolan, M. Flaska, S.A. Pozzi, D. Chichester., J. Nucl. Mater. Manage. 38 (1) (29) 4. [3] S.A. Pozzi, S.D. Clarke, M. Flaska, P. Peerani, Nucl. Instr. and Meth. in Phys. Res. A 68 (29) 31. [4] R. Koohi-Fayegh, Stuart Green, Malcolm C. Scott, Nucl. Instr. and Meth. A 46 (21) 391. [5] W.R. Burrus, FERD and FERDOR type unfolding codes, Report ORNL/RSIC-4, pp. 2 23, 1976. [6] S. Avdic, S.A. Pozzi, V. Protopopescu, Nucl. Instr. and Meth. A 565 (26) 742. [7] Y. Xu, T. Downar, M. Flaska, A sequential least-squared algorithm for neutron spectrum unfolding from pulse-height distributions measured with liquid scintillators, (M&C+SNA), pp. 11, 27. [8] S.A Pozzi, E. Padovani, M. Marseguerra, Nucl. Instr. and Meth. in Phys. Res. A 513 (23) 55. [9] L. Cartegni, S.A. Pozzi, Measurement and simulation of liquid scintillator neutron response, ORNL TM-24/315. [1] S. Guardini, G. Guzzi, F. Mousty, S. Baumann, E. Kuhn, P. de Regge, PERLA: quality control provisions applied in the preparation and characterization of Pu-bearing Perla Standards. Report EUR 1338EN, CEC JRC Ispra, 199. [11] E.F. Shores, Appl. Radiat. Isot. 62 (25) 699. [12] S.D. Clarke, M. Flaska, S.A. Pozzi, P. Peerani, Nucl. Instr. and Meth. A 64 (29) 618. [13] M. Flaska, S.A. Pozzi, Nucl. Instr. and Meth. A 577 (27) 654.