POINT SOURCES OF POLLUTION: LOCAL EFFECTS AND IT S CONTROL Vol. II - Sampling, Measurement and Assessment - Zulin Zhang and Gang Yu

Similar documents
METHOD 3010A ACID DIGESTION OF AQUEOUS SAMPLES AND EXTRACTS FOR TOTAL METALS FOR ANALYSIS BY FLAA OR ICP SPECTROSCOPY

Basic Digestion Principles

METHOD 7060A ARSENIC (ATOMIC ABSORPTION, FURNACE TECHNIQUE)

Test Method: CPSC-CH-E

METHOD 3600B CLEANUP

Tex-620-J, Determining Chloride and Sulfate Contents in Soil

Phosphorus, Total. USEPA 1 PhosVer 3 with Acid Persulfate Digestion Method Method to 3.50 mg/l PO. Test preparation

Product Safety Reference Manual. Book 5 - Laboratory Policies and Procedures C

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.

Part II. Cu(OH)2(s) CuO(s)

Separation and Qualitative Determination of Cations

IAEA-TECDOC-9SO. Sampling, storage

TECHNETIUM-99 IN SOIL

THE CATHOLIC UNIVERSITY OF EASTERN AFRICA A. M. E. C. E. A

Chromatography & instrumentation in Organic Chemistry

General Chemistry I CHEM-1030 Laboratory Experiment No. 2 Physical Separation Techniques

Revision: 11 (MBAS) ALLOWAY METHOD OUTLINE. Standard Laboratory Method:

Laboratory 23: Properties of Aldehydes and Ketones

METHOD 3600C CLEANUP

Conductivity of Electrolytes in Solution

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.

Sampling. Information is helpful in implementing control measures for reducing pollutant concentration to acceptable levels

Current State of Extraction Don t Be Deceived! Sharon F. Webb, Ph.D. Director of Quality Program

APPENDIX C TO PART 136 INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION SPECTROMETRIC METHOD FOR TRACE ELEMENT ANALYSIS OF WATER AND WASTES METHOD

What type of samples are common? Time spent on different operations during LC analyses. Number of samples? Aims. Sources of error. Sample preparation

To explore solubilities and reactivities of different metal ions. To identify ions present in unknown solutions using separation methods.

DR/4000 PROCEDURE LEAD. 2. The display will show: 3. Fill a 250-mL graduated cylinder to the 250-mL mark with sample.

Determinations by Atomic Absorption Spectroscopy and Inductively Coupled Plasma-Atomic Emission

3. Separation of a Mixture into Pure Substances

Zinc Metal Determination Perkin Elmer Atomic Absorption Spectrometer AAnalyst Procedures

Principles of Gas- Chromatography (GC)

CHAPTER CHROMATOGRAPHIC METHODS OF SEPARATIONS

METHOD 9040B. ph ELECTROMETRIC MEASUREMENT

enable measurement. This method separates these isotopes effectively.

Chem 1B Saddleback College Dr. White 1. Experiment 5: Separation and Identification of Group I Cations (The Chloride Group: Ag +, Pb 2+, and Hg 2

Scientific Observations and Reaction Stoichiometry: The Qualitative Analysis and Chemical Reactivity of Five White Powders

Colorimetric Method Method to 0.70 mg/l Ag Powder Pillows

AIR. Ambient, Indoor, Workplace Air and Stack Emissions Proficiency Testing Scheme. Sample Preparation Instructions Round 1

GRAVIMETRIC ANALYSIS OF A CHLORIDE SALT. REFERENCES: Nelson, J., Chemistry: The Central Science, 3 rd edition, Prentice-Hall, 1985

Experiment Nine Thin Layer Chromatography

To precipitate nickel (II) sulfide, the sulfide ion concentration must be a lot larger:

URANIUM IN SOIL. Analytical Procedure (2 GRAM SAMPLE) 1. SCOPE

GRIGNARD REACTION Synthesis of Benzoic Acid

TECHNETIUM-99 IN WATER

EXPERIMENT #8 The Chemistry and Qualitative Analysis of Cations: Group I

METHOD 9012 TOTAL AND AMENABLE CYANIDE (COLORIMETRIC, AUTOMATED UV)

Available online at ScienceDirect. Procedia Environmental Sciences 31 (2016 )

Introduction to Pharmaceutical Chemical Analysis

Oxygen Demand, Chemical

Oxygen Demand, Chemical

The ratio of the concentrations of a substance in the two solvents at equilibrium is called its distribution coefficient, K D :

Cadmium Reduction Method (Using Powder Pillows or AccuVac Ampuls)

25. Qualitative Analysis 2

Hach Company TNTplus 835/836 Nitrate Method Spectrophotometric Measurement of Nitrate in Water and Wastewater

Cadmium Reduction Method Method to 10.0 mg/l NO 3 N (MR, spectrophotometers) 0.2 to 5.0 mg/l NO 3 N (MR, colorimeters)

á233ñ ELEMENTAL IMPURITIES PROCEDURES

Atmospheric Analysis Gases. Sampling and analysis of gaseous compounds

PROCEDURES. Pharmacopeial Forum 2 Vol. 36(1) [Jan. Feb. 2009]

Expt 10: Friedel-Crafts Alkylation of p-xylene

Uranium from water sample

Experiment 18 - Absorption Spectroscopy and Beer s Law: Analysis of Cu 2+

Chem 2115 Experiment #10. Acids, Bases, Salts, and Buffers

Method 0060 or Method 29. Method for Determining Metals and Mercury Emissions in Stack Gas

REMOVAL OF HEAVY METALS USING COMBINATION OF ADSORBENTS - A CASE STUDY USING INDUSTRIAL WASTE WATER

Chemistry Instrumental Analysis Lecture 27. Chem 4631

Using FIMS to Determine Mercury Content in Sewage Sludge, Sediment and Soil Samples

5. SEPARATION OF MIXTURES, PURIFICATION OF SOLIDS Objectives

TECHNETIUM-99 IN WATER

DETERMINATION OF CHEMICAL OXYGEN DEMAND COD

Skill Building Activity 2 Determining the Concentration of a Species using a Vernier Spectrometer

Cadmium Reduction Method Method 8171 MR (0.1 to 10.0 mg/l NO 3

Diquat 1,1 -ethylene-2,2 -bipyridium dibromide salt Paraquat 1,1 -dimethyl-4,4 -bipyridium dichloride salt Initial Preparation

Hach Company TNTplus TM Phosphorus Spectrophotometric Measurement of Phosphorus in Water and Wastewater

To observe trends in solubility and exceptions to these trends. To write chemical formulas based on cation/anion charges.

Identification of an Unknown Compound through Mass Correlations

Experiment 12: Grignard Synthesis of Triphenylmethanol

Approximate Volatile Acids by Titration

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

DR/4000 PROCEDURE NITRATE. Using Powder Pillows

Sodium Chloride - Analytical Standard

A cream precipitate formed

Inside the Black Box of an Environmental Testing Laboratory Basic Analytical Procedures

Determination of trace anions in concentrated hydrofluoric acid

Handbook of Inductively Coupled Plasma Spectrometry

Appendix: Laboratory Testing Methods

Hach Method Total Organic Carbon in Finished Drinking Water by Catalyzed Ozone Hydroxyl Radical Oxidation Infrared Analysis

METHOD 7199 DETERMINATION OF HEXAVALENT CHROMIUM IN DRINKING WATER, GROUNDWATER AND INDUSTRIAL WASTEWATER EFFLUENTS BY ION CHROMATOGRAPHY

POINT SOURCES OF POLLUTION: LOCAL EFFECTS AND IT S CONTROL Vol. II - Contaminant Fate and Transport Process - Xi Yang and Gang Yu

Experiment # 9 : Cation Analysis: Group ( I )

Application Note #119 Alkalinity and Chloride by Titration

2 Set up an apparatus for simple distillation using this flask.

Determination of Nutrients. Determination of total phosphorus. Extraktion with aqua regia, reflux method. Introduction

Thin Layer Chromatography

QUALITATIVE ANALYSIS OF GROUP I CATIONS

Advanced Unit 7: Chemistry Practical Examination (SET A) Candidates must have: Scientific calculator Ruler

EXPERIMENT 6. Physical and Chemical Changes Part 2 INTRODUCTION

Chemical Reactions: The Copper Cycle

Manganese III Digestion Method * (with chloride removal)

Photosynthesis Lab. Table 1: Comparison of the two parts of photosynthesis.

Cadmium Reduction Method Method to 0.50 mg/l NO 3 N (LR) Powder Pillows

Transcription:

SAMPLING, MEASUREMENT AND ASSESSMENT Zulin Zhang and Gang Yu Department of Environmental Sciences and Engineering, Tsinghua University, Beijing, P. R. China Keywords: sampling, sample pretreatment, measurement, assessment, instrument analysis, environmental analysis. Contents 1. Introduction 2. Sampling and samples pretreatment 2.1. Samples pretreatment for metals (sample digestion for metals) 2.2 Samples pretreatment for organics 3. Measurement and determination 3.1. Metal determination 3.2. Organic determination 3.3. Air Analysis 4. Quality Assurance Glossary Bibliography Biographical Sketches Summary Measurements play a key role in the protection of the environment. They are needed to identify problems and to monitor the effectiveness of control and abatement technology. Decisions on vital questions such as the habitability of an area, the safety of drinking water, and the continued operations of an industrial plant are often based on measurement data. Equipment and technology for quantitative measurement are increasingly better developed these days, enabling us to identify new problems that may have existed for a long time. Consequently, stringent regulations can be set, and a cleaner environment can be assured with suitable enforcement. In this article, sampling and sample pretreatment, instrumental analysis and the quality assurance of environmental measurements will be addressed. 1. Introduction The analysis of chemical pollutants in environmental media entered a new phase in the 1990s. Modifications in instrumentation, sampling, and sample preparation techniques have become essential to keep up with the requirements of achieving ppt to low ppb detection levels, as well as to achieve faster speed of analysis. In addition, more stringent qualitycontrol (QC) requirements in analytical methods have become necessary to obtain high quality data. This has led to the many new methodologies that are different from the conventional macro and semimicro analytical approach.

Environmental analysis today, like any other scientific field, relies heavily on instrumentation. Organic pollutants are primarily determined by gas chromatography (GC), gas chromatography/mass spectrometry (GC/MS), and high performance liquid chromatography (HPLC), methods. There is, however, also a growing interest in alternative techniques, such as Fourier transform infrared spectroscopy (FTIR). Specially designed capillary columns have come up for GC analysis to achieve high resolution and better separation of many closely eluting isomers. Another major development in organic analysis is HPLC determination using postcolumn derivatization. Many classes of substances such as aldehydes, ketones, and carboxylic acids may be accurately determined by using such techniques. Most organic compounds are best analyzed by GC/MS. Such GC/MS or GC analysis, however, is preceded by either a purge and trap concentration step or a liquid or solid phase extraction step using a suitable organic solvent. The purge and trap method for aqueous samples is applicable for volatile substances that have lower solubility in water. A mass spectrometer should be used wherever possible to identify the compounds more correctly. Although it has a lower sensitivity than other GC detectors, mass spectrometry is, by far, the most confirmatory test for compound identification. Methodologies for inorganic anions and metals have undergone rapid growth similar to chromatographic techniques. Notable among these technologies are the atomic absorption and emission spectroscopy and ion chromatography (IC). The latter is a rapid method to determine several anions, simultaneously. The IC approach may be modified further to measure such weak anions as carboxylates and cyanide. Sample preparation is a key step in all environmental analysis. Two major areas of development in this area have been solid phase extraction of pollutants from aqueous and nonaqueous matrices. These processes, along with gel permeable chromatography, are relatively simple, fast, and less expensive, and provide efficient methods of removing interferences. The methods of analysis of pollutants in ambient air have developed tremendously in recent years. Although these methods employ the same analytical instrumentation (i.e. GC, GC/MS, HPLC, IR, atomic absorption, ion chromatography, and the electrode methods), the air sampling technique is probably the most important component of such analysis. The use of cryogenic traps and high pressure pumps has supplemented the impinger and sorbent tube sampling techniques. The numbers of pollutants that are currently regulated constitute only a fraction of those found in the environment. In addition, their chemical characteristics and concentrations may vary widely. New and alternative methodologies that are simple, rapid, and reliable need to be developed. Enzyme immunoassay and portable GC and IR techniques need greater attention. This article presents an outline description of various environmental analytical methodologies, including sampling, sample preparations, cleanup, and instrumentation to identify different classes of substances and selected individual compounds and also to

derive a method to analyze uncommon pollutants based on their physical and chemical properties, as well as quality assurance and quality control. 2. Sampling and samples pretreatment 2.1. Samples pretreatment for metals (sample digestion for metals) Aqueous and nonaqueous samples must be digested with an acid before their analysis by atomic absorption or atomic emission spectrophotometry. The metals and their salts present in the sample are converted into their nitrates due to the fact that the nitrates of all metals are soluble in water. Therefore, concentrated nitric acid by itself or in conjunction with hydrochloric acid, sulfuric acid, perchloric acid, or hydrofluoric acid is used in sample digestion for the determination of total metals. Nitric acid alone is, however, adequate for digestion of most metals. Acid digestion is performed using a small volume (5 to 10 ml) of nitric acid alone or in conjunction with one of the previously mentioned acids on a hot plate. Alternatively, a laboratorygrade microwave unit, specifically designed for hot acid digestion, can be used. When the sample is boiled with acid, the latter should not be allowed to dry. The acid extract after boiling and cooling is diluted with water to a measured final volume for analysis. Acids combination HNO 3 HCl HNO 3 H 2 SO 4 HNO 3 HClO 3 HNO 3 HF Suggested use Sb, Sn, Ru and readily oxidizable organic matter Ti and readily oxidizable organic matter Difficult to oxidize organic materials Siliceous materials Table 1: Acid combination suggested for sample preparation For the determination of acidsoluble metals, contamination and loss are of prime concern. Dust in the laboratory environment, impurities in reagents and improperly cleaned laboratory apparatus with which the sample comes into contact, are all potential sources of contamination. Sample containers can introduce either positive or negative errors in the measurement of metals by (a) contributing contaminants through leaching or surface desorption and/or (b) by depleting concentration through adsorption. Laboratory glassware, including the sample collection container and the polyethylene sample storage bottle, as well as the filtering apparatus, should be thoroughly washed with detergent and tap water; thoroughly rinsed with (1+1) nitric acid, tap water, (1+1) hydrochloric acid, tap water and finally deionized distilled water in that order. At the time of sample collection, the sample container is rinsed with the sample solution and the rinse portion discarded. The container is then filled with approximately 800 ml of sample, acidified with 2mL of (1+1) nitric acid and mixed. For most ambient waters the acid addition will lower the ph to near 2, but not lower than 1.75. The container is sealed, placed in an ice chest at 4 o C,

and returned to the laboratory. The date and time of preservation should be recorded on the sample tag. The sample should not be held more than 3 days at 4 o C from the day of collection before processing is started. The filtrate is estimated to be stable for 30 days. For determination of total recoverable elements in solid samples (sludge, soils, and sediments), the sample should be mixed thoroughly to achieve homogeneity and a portion of the sample, of 1.0±0.01 g, accurately weighed and transferred to a 250 ml Phillips beaker. Nitric acid, 4 ml (1+1), and 10 ml (1+4) hydrochloric acid are then added, and the mixture covered with a watch glass. The sample is heated on a hot plate and gently refluxed for 30 min. Very slight boiling may occur, but vigorous boiling must be avoided to prevent the loss of HClH 2 O azeotrope. For determination of total recoverable elements in biological tissues, appropriate individual tissue samples should be taken soon after collection and must be taken prior to freezing. If dissection of the tissue cannot be performed immediately after collection, it should be placed in a plastic bag, sealed and placed on ice or refrigerated at approximately 4 o C. Prior to dissection, the tissue should be rinsed with metalfree water and blotted dry. Dissection should be performed within 24 hours of collection. Each individual tissue sample should also be rinsed with metalfree water, blotted dry, and frozen at less than 20 o C. Tissue samples of up to 5 g should be taken using a special implement and handled with plastic forceps. A maximum holding time for frozen samples has not been determined. Of the elements in the Periodic Table more than two thirds are metals. Although many of these metals are toxic, only a few are major environmental pollutants, because of their widespread use. USEPA has classified 13 metals as priority pollutants: aluminum, antimony, arsenic, beryllium, cadmium, chromium, copper, lead, mercury, nickel, selenium, silver, and zinc. The Resource Conservation and Recovery Act has listed eight metals whose mobility in the soil is measured to determine the characteristic of toxic wastes. These metals include arsenic, barium, cadmium, chromium, lead, mercury, selenium, and silver all but one from the above list of priority pollutant metals. Metals in general can be analyzed by the following techniques: Colorimetry Atomic absorption or atomic emission spectrophotometry In addition, some metals may be determined by other methods, including ionselective electrode, ion chromatography, electrophoresis, neutron activation analysis, redox titration, and gravimetry. Atomic adsorption or emission spectrophotometry is the method of choice, because it is rapid, convenient, and gives the low detection levels as required in the environmental analysis. Although colorimetry methods can give accurate results, they are time consuming and a detection limit below 10 ug/l is difficult to achieve for most metals.

TO ACCESS ALL THE 14 PAGES OF THIS CHAPTER, Visit: http://www.eolss.net/eolsssampleallchapter.aspx Bibliography Barcelo D. (2000). Sample Handling and Trace Analysis of Pollutants: Techniques, Applications and Quality Assurance. Elsevier Science. [This book introduces the analytical method on trace pollutants of the samples] Patnaik P. (1997) Handbook of Environmental Analysis: Chemicals Pollutants in Air, Water, Soil, and Solid Wastes. CRC Press, Inc. [This book presents the chemical analysis of pollutants in different matrices in the environment] Smolery K. (1992). Methods for determination of Metals in Environmental Samples. CRC Press, Inc. [This book describes the determination of metals in the environmental samples] Subramanian G. (1995). Quality Assurance in Environmental Monitoring. Weinheim, New York. [This book introduces Quality Assurance when doing environmental monitoring] Yen T. F. (1999). Environmental Chemistry: Essentials of Chemistry for Engineering Practice, Volume 4A. PrenticeHall, Inc. [This book presents basic concepts on environmental chemistry in the engineering process] Biographical Sketches Dr. Zulin Zhang is a lecturer in the Department of Environmental Sciences and Engineering, Tsinghua University, Beijing, China. He received the Ph.D. (2001) in environmental science from Xiamen University. His current interests focus on analytic method and behavior of persistent organic pollutants. Dr. Gang Yu is a Professor and the Deputy Head, Department of Environmental Science and Engineering, Tsinghua University, Beijing, China. He received an M.S. (1989) degree in Environmental Chemistry from Nanjing University and a Ph.D. (1992) in Environmental Chemistry from the Research Center of Ecoenvironmental Science, Chinese Academy of Sciences. His current interests focus on persistent organic pollutants, including analytical methods, behavior in multiple media, disposal technology, remediation technology, and control strategy.