CalMaster. ABB Instrumentation

Similar documents
Compact Orifice FlowMeter

Field IT 50T Series Transmitters

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

ISSP User Guide CY3207ISSP. Revision C

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

QUANTUM CONCEPT. Swimming User s Manual

AM 500A 500 WATT AM 1A 1 KILOWATT AM BROADCAST TRANSMITTERS. October, 1999 IM No

473 Dew Point Hygrometer

Dewpoint Meter Data Sheet / Instructions

WeatherHub2 Quick Start Guide

O P E R A T I N G M A N U A L

Data Sheet / Instructions. Dewpoint MeterO

Dielectric Analysis of Solid Insulations

Operating Instructions for Digital Manometer. Model: MAN-SD

Lamp and Control Panel (Lamp Panel)

Installation guide 862 MIT / MIR

473 Dew Point Hygrometer

Operation Manual. SPECTRO-NANO4 Nucleic Acid Analyzer PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

Sitting height... 6 Back tilt and back height... 6 Armrest... 7 Brakes... 7 Charging VELA Tango 300E... 7

DIGITAL THERMOMETER OPERATOR S MANUAL

NOVALYNX CORPORATION MODEL 110-WS-16BP BAROMETRIC PRESSURE SENSOR INSTRUCTION MANUAL

рн PRO Controller The device is used to control and regulate ph level in hydroponic systems and water preparing units automatically USER MANUAL

Doc No. KF08-002D. Portable Ultrasonic Flowmeter UFP-20. Installation & Operation Manual

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER

INSTALLATION INSTRUCTIONS FRONT PLOW MOUNT KIT Part Number: Application: Polaris Sportsman 400, 500, 800

Navigator 550 Hydrazine wet-section. Measurement made easy

473-SHX Dew Point Mirror

Commercial Generator Parts Catalog. PROTEC Series

FIELD SPECTROMETER QUICK-START GUIDE FOR FIELD DATA COLLECTION (LAST UPDATED 23MAR2011)

Dielectric Analysis of Insulation Liquids

Structure Monitoring Technology. Features. Ordering Information. Trigger Tape. A2 Pulse Counter (Optional) Solar Radiation Sensor

SC125MS. Data Sheet and Instruction Manual. ! Warning! Salem Controls Inc. Stepper Motor Driver. Last Updated 12/14/2004

Ocean Optics Red Tide UV-VIS Spectrometer (Order Code: SPRT-UV-VIS)

Field Pro Operation and Installation Manual

Eppendorf Temperature Verification System. Operating manual /0909

SkyScan EWS-PRO - Manual -

Atomic and nuclear physics

PHOENIX CONTACT - 04/2016. Features

AIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL

Exercise 2-2. Titration of a Strong Acid EXERCISE OBJECTIVES

The Fundamentals of Moisture Calibration

Atomic and nuclear physics

INSTALLATION INSTRUCTIONS PLOW MOUNT KIT Part Number: Application: Honda Foreman 500

HAZARD COMMUNICATION SAFETY PROGRAM

HT600 Dat e Code: 2 - HT MW Purchase Date: PLEASE RETAIN THIS INSTRUCTION MANUAL FOR FUTURE REFERENCE. All Rights Reserved

566/568. Infrared Thermometers. Getting Started

AKD SYSTEM CONFIGURATION WITH KOLLMORGEN DDL LINEAR MOTORS By Kenny Hampton 1/12/2017 Rev. L

User Manual VX4750 Function Generator Module

Technical Procedure for Glass Refractive Index Measurement System 3 (GRIM 3)

IR F ( C) ENGLISH INSTRUCTION MANUAL. Thermometer

ph electrode Instruction Manual For use with the RAH-210 & RPH-250

Spectrometer User s Guide

INSTRUCTION MANUAL Milwaukee Refractometer MA881 Refractometer for Invert Sugar Measurements

Differential ph Probe Type 18

Exercise 2-4. Titration of a Buffer Solution EXERCISE OBJECTIVES

INSTALLATION INSTRUCTIONS ATV Plow Blade Part Number: (50 ), (54 ), or (60 ) Application: All Terrain Vehicles

CHROMA Colorimeter Model 252

INSTALLATION INSTRUCTIONS ProVantage Plow Pulley Part Number: 84526

In Association With. Introduces. TPT Contractor

IV. EQUIPMENT a. Horiba LA 950 main unit b. Dry sample unit that has a silencer behind it c. Cell slide unit that holds

symphony Multisensor Probes

In-System Serial Programming (ISSP) Guide

MODEL H3022 MAGNETIC BASE / DIAL INDICATOR / CALIPER COMBO OWNER'S MANUAL

ER2 Short-head Electric Chain Hoist

Experiment 14 It s Snow Big Deal

Circular Motion and Centripetal Force

Assembly and Operation Manual. April 2016

Product Manual (Revision D) Original Instructions. Speed Switch and Integrated Speed Switch. Installation and Operation Manual

Vet Photometer DP 700 Operating Manual. Version V5.9

Lab Activity H4 It s Snow Big Deal

A clock designed in close consultation with people living with Dementia.

WARNING. INJURY HAZARD Failure to observe these instructions could lead to severe injury or death.

Instruction Manual HI Refractometer for Sodium Chloride Measurements

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

Assembly Instructions for the 1-Wire Weather Station V2.0/V3.0

S-5743 A Series 125 C OPERATION HIGH-WITHSTAND VOLTAGE HIGH-SPEED BIPOLAR HALL EFFECT LATCH IC. Features. Applications. Package.

Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202

ph Probe ReallyEasyData com

Microcare LCD Solar MPPT User Documentation

INSTRUCTION MANUAL. Laser Diode Sarcomere Length. Aurora Scientific Inc. 360 Industrial Parkway South, Unit 4 Aurora, Ontario, Canada L4G 3V7

Evaluation Board for 8-/10-/12-Bit, Parallel Input, Dual-Channel, Current Output DAC EVAL-AD5428/AD5440/AD5447EB

Lab 1 Uniform Motion - Graphing and Analyzing Motion

STATIC GAS MONITOR Type SGM/DEW Revision A of 20 aprile 2016

INSTALLATION INSTRUCTIONS ATV SNOW PLOW Mounting Kit: PN Application: HONDA 300

ABLIC Inc., Rev.2.2_02

S-57M1 Series HIGH-SPEED BIPOLAR HALL EFFECT LATCH. Features. Applications. Package. ABLIC Inc., Rev.1.

Food Safety and Quality Management System

Acceleration/Velocity/Displacement VIBRATION METER

Periodic Inspection and Testing of Electrical Installations Sample Test ( ) Version 1.3 July 2018

VIBRATION METER. Instruction Manual.

Small Gage Pressure Sensor

ON SITE SYSTEMS Chemical Safety Assistant

Perseverance. Experimentation. Knowledge.

Quick Start Guide New Mountain Visit our Website to Register Your Copy (weatherview32.com)

SSi Super Systems Inc.

N) manual. Biomaster Operating manual

PiCUS Calliper Version 3

Detection of S pole Detection of N pole Active "L" Active "H" Nch open-drain output Nch driver built-in pull-up resistor. f C = 250 khz typ.

PARTS MANUAL 2 INCH CHIPPER/SHREDDER. SC cc SUBARU

Transcription:

CalMaster Instruction Manual CalMaster ASEA BROWN BOVERI ABB Instrumentation

ABB KENT-TAYLOR The Company ABB Kent-Taylor is an established world force in the design and manufacture of instrumentation for industrial process control, flow measurement, gas and liquid analysis and environmental applications. As a part of ABB, a world leader in process automation technology, we offer customers application expertise, service and support worldwide. We are committed to teamwork, high quality manufacturing, advanced technology and unrivalled service and support. The quality, accuracy and performance of the Company s products result from over 100 years experience, combined with a continuous program of innovative design and development to incorporate the latest technology. The NAMAS Calibration Laboratory No. 0255(B) is just one of the ten flow calibration plants operated by the Company, and is indicative of ABB Kent-Taylors dedication to quality and accuracy. BS EN ISO 9001 R E G IS T E R E D FIR M St Neots, U.K. Cert. No. Q5907 Stonehouse, U.K. Cert. No. FM 21106 EN 29001 (ISO 9001) Lenno, Italy Cert. No. 9/90A Stonehouse, U.K. Cert. No. 0255 Use of Instructions Warning. An instruction that draws attention to the risk of injury or death. Note. Clarification of an instruction or additional information. Caution. An instruction that draws attention to the risk of damage to the product, process or surroundings. Information. Further reference for more detailed information or technical details. Although Warning hazards are related to personal injury, and Caution hazards are associated with equipment or property damage, it must be understood that operation of damaged equipment could, under certain operational conditions, result in degraded process system performance leading to personal injury or death. Therefore, comply fully with all Warning and Caution notices. Information in this manual is intended only to assist our customers in the efficient operation of our equipment. Use of this manual for any other purpose is specifically prohibited and its contents are not to be reproduced in full or part without prior approval of Technical Communications Department, ABB Kent-Taylor. Health and Safety To ensure that our products are safe and without risk to health, the following points must be noted: 1. The relevant sections of these instructions must be read carefully before proceeding. 2. Warning labels on containers and packages must be observed. 3. Installation, operation, maintenance and servicing must only be carried out by suitably trained personnel and in accordance with the information given. 4. Normal safety precautions must be taken to avoid the possibility of an accident occurring when operating in conditions of high pressure and/or temperature. 5. Chemicals must be stored away from heat, protected from temperature extremes and powders kept dry. Normal safe handling procedures must be used. 6. When disposing of chemicals ensure that no two chemicals are mixed. Safety advice concerning the use of the equipment described in this manual or any relevant hazard data sheets (where applicable) may be obtained from the Company address on the back cover, together with servicing and spares information.

CONTENTS Contents Page 1 PREPARATION... 2 1.1 Unpacking... 2 2 INSTALLATION... 2 2.1 Adapting the MagMaster Transmitter... 2 2.2 Preparing the MagMaster Transmitter for Verification... 3 2.2.1 Removing the Covers... 3 2.2.2 Fitting the Adaptor Board.. 4 2.2.3 Wiring the Adaptor Socket 5 2.2.4 System Setup... 6 3 OPERATION... 7 3.1 Software Installation... 7 3.1.1 Windows 3.1 or 3.11... 7 3.1.2 Windows 95... 7 3.2 Initialising the CalMaster... 7 3.3 Battery Charging... 7 1

1 PREPARATION 2 INSTALLATION 1.1 Unpacking Unpack and visually inspect the CalMaster. Also packed with the CalMaster are: a) CalMaster sensor test lead set. b) CalMaster to MagMaster communication lead set (includes three test probes for frequency measurement). c) Adaptor PCBs incorporating a plug to accept the socket in item d) below. d) Socket which fits into item c) above. The socket is first terminated with the sensor cable. e) One lead to interconnect the CalMaster and a computer (Serial Data Connection). f) Screwdriver for terminals. g) Two 'CalMaster Software' Disks. h) This Instruction Manual. i) Mains operated battery charger j) Lead for charging battery from12 Volts. Save packing materials for any re-shipment, or to support any claim of shipment damage. All damage claims are made against the carrier and are the responsibility of the customer. 2.1 Adapting the MagMaster Transmitter To enable a MagMaster system to be tested by the CalMaster it is necessary to initially fit a small adaptor board to the MagMaster transmitter. This adaptor is provided with the CalMaster Unit. Once the adaptor is fitted to the MagMaster transmitter, the CalMaster can be easily connected to the transmitter for testing at any time. Extra adaptor kits are available from the Company The adaptor is supplied in the form of a PCB fitted with connectors which fit into the sensor connection terminals of the MagMaster transmitter. A connection socket is also provided, which after termination with the sensor cable, is connected with the plug on the adaptor PCB. This provides a flexible means of inserting connecting leads from the CalMaster, when testing is required, and reconnecting the MagMaster sensor wiring when the testing is complete. Adaptor PCB fitted with plug, and connectors for direct connection to terminals Plug Socket for termination of sensor cable Fig. 2.1 Adaptor Board for Transmitter 2

2 INSTALLATION 2.2 Preparing the MagMaster Transmitter for Verification 2.2.1 Removing the Covers Remove Protection Cover 4 1 Slide Down Pull Out Slightly... 2 2...and Slide Off 3 Slacken Captive Screws Fig. 2.2 Access to fit Adaptor Board 3

PLS OV ALARM 1 EXT I/P+ EXT I/P- TX- SIG RX- SIG TX+ SIG RX+ SIG OVC 2 INSTALLATION 2.2.2 Fitting the Adaptor Board (Fig. 2.3 and 2.4) a) Turn off the power to the MagMaster. b) Record the position of the sensor cable wiring and remove the wiring from the terminals. Slacken the terminal screws by at least 6 turns. c) Carefully ease the sensor wiring to one side and arrange the adaptor board so that the extended pins fit into the terminals previously occupied by the sensor wiring see Fig.2.4. d) Fit and tighten the securing screw to the corner of the adaptor board. e) Tighten the associated terminal block screws. Red (CD 1) IC 2 SIG GND DS 1 SIG 1 DS 2 Yellow (CD 2) CD 1 CD 2 White Coax Blue Inner (SIG 1) Screen (DS 1) Violet Grey Coax Pink Inner (SIG 2) Screen (DS 2) Ground Wire (Safety Earth) Fig 2.3 Normal Sensor Wiring in the Transmitter Adaptor Board N + L F OUT A ALARM 2 F OUT B PLS OV Fig 2.4 Fitting the Adaptor Board 4

2 INSTALLATION CD1 CD2 GROUND SIG GND DS 1 SIG 1 SIG 2 DS 2 3 2 Yellow Red 1 Pink Grey Blue White Caution. Remove any exposed black conductive layer from the inner insulation of both coaxial cables Fig 2.5 Fitting the Sensor Wiring onto the Adaptor Socket 2.2.3 Wiring the Adaptor Socket (Fig. 2.5) The wires in the sensor cable must now be wired to the 8-way adaptor socket which will then connect to the plug on the adaptor board. 1 Adjust the wire lengths of the sensor cable to allow for termination and subsequent removal of the adaptor socket. 2 Insert the sensor cable wiring into the socket as shown in Fig 2.5, and tighten the plug screws with the screwdriver provided. Warning. Testing the MagMaster involves operation with the MagMaster terminal cover removed, exposing live terminals. Take precautions to avoid electric shock hazard. Switch on the power to the MagMaster and check that the system operates correctly. If the MagMaster operates correctly, either the transmitter covers can be replaced for normal working or the MagMaster can be tested by the CalMaster. Caution. Ensure that no bare wires touch each other; in particular, ensure that there is no connection between the screens of the grey and white coaxial wires. 3 Insert the adaptor socket into the plug on the adaptor PCB. 5

ASEA BROWN BOVERI 2 INSTALLATION 2.2.4 System Setup (Fig. 2.6) Warning. Care is needed when CalMaster is used with cathodically protected MagMasters. Cathodically protected installations, wired as directed in the MagMaster manual, which isolate the sensor using earthing flanges, are electrically earthed and do not pose any safety issues. When apparatus, such as CalMaster or the PC, are connected to systems which 'float' the sensor at the cathodic potential, this apparatus will also float at the cathodic potential and therefore must not be grounded or accidentally grounded. With the adaptor PCB installed in the MagMaster Transmitter as detailed in Section 2.2.2, and the sensor cable plugged into the adaptor as for normal operation: a) Connect lead 3 of the CalMaster to the MagMaster 9-pin D-Type socket. The three small probes should not be connected until requested to do so by the CalMaster software. For details of when to connect these probe leads, follow the instructions on the provided software see Section 3.2. For details of where to connect the probe leads, follow the 'on-line help' under the heading, 'test lead connections'. b) Connect the 9-Pin D-Type socket on the CalMaster to a computer (Serial Comms Connection). Note.The use of CalMaster with a line powered desktop PC, as opposed to a portable, battery powered PC, is not recommended, as the resulting ground (eqrth) loop can corrupt the sensitive CalMaster measurements. In these circumstances, an external RS232 isolator between the PC and the CalMaster will effect a solution MagMaster CalMaster CalMaster 1 2 3 4 Sensor Sensor Test Lead Set Fig. 2.6 Connection Details for Initialisation 6

3 OPERATION 3 OPERATION 3.1 Software Installation Note. The CalMaster Program can be used with or without a 'Mouse'. Where instructions say 'Select', either click on the item with the left hand mouse button, or use the 'TAB' key to move between fields and press the 'ENTER' key to complete the selection. Insert the first CalMaster floppy disk into the computer disk drive and proceed as follows: 3.1.1 Windows 3.1 or 3.11 a) Select 'RUN' from the Program or File Manager menu. b) Type 'a:setup' or 'b:setup', depending on the floppy drive designation. c) Press 'ENTER' and follow instructions. 3.1.2 Windows 95 a) Press 'START' b) Select 'Settings', 'Control Panel' and double click on 'Add/Remove Programs'. c) Choose 'Install' and follow the instructions. 3.2 Initialising the CalMaster Note. It is advisable to avoid the use of radio equipment in the vicinity of a CalMaster/MagMaster test setup, during testing. a) From Windows 'Program Manager' open the 'ABB Applications' folder and double click on the 'CalMaster' icon. The program automatically finds the MagMaster and opens up to the Main 'ABB' Screen. d) Select 'Test Meter', and the 'Verification Information' screen is displayed. c) Follow the on screen instructions and on screen Help as required click on the Help button or press F1. 3.3 Battery Charging The CalMaster internal battery may be charged using the mains charger unit supplied, or from a 12 volt vehicle connector for which a lead is also supplied. Charging is automatic and takes approximately 4 hours for a discharged battery. For further information, refer to <battery monitoring> from the CalMaster <options> menu. 7

8 NOTES

PRODUCTS & CUSTOMER SUPPORT A Comprehensive Product Range Analytical Instrumentation Transmitters On-line ph, conductivity, and dissolved oxygen transmitters and associated sensing systems. Sensors ph, redox, selective ion, conductivity and dissolved oxygen. Laboratory Instrumentation ph and dissolved oxygen meters and associated sensors. Water Analyzers For water quality monitoring in environmental, power generation and general industrial applications including: ph, conductivity, ammonia, nitrate, phosphate, silica, sodium, chloride, fluoride, dissolved oxygen and hydrazine. Gas Analyzers Zirconia, paramagnetic, infrared, thermal conductivity. Controllers & Recorders Controllers Digital display, electronic, pneumatic. Discrete single-loop and multi-loop controllers which can be linked to a common display station, process computer or personal computer. Recorders Circular and strip-chart types (single and multipoint) for temperature, pressure, flow and many other process measurements. Electronic Transmitters Smart & Analog Transmitters For draft, differential, gauge and absolute pressure measurement. Also, liquid level and temperature I to P Converters and Field Indicators Customer Support ABB Kent-Taylor provides a comprehensive after sales service via a Worldwide Service Organization. Contact one of the following offices for details on your nearest Service and Repair Centre. United Kingdom ABB Kent-Taylor Limited Tel: +44 (0)1480 470781 Fax: +44 (0)1480 217948 United States of America ABB Kent-Taylor Inc. Tel: +1 716 2926050 Fax: +1 716 2736207 Italy ABB Kent-Taylor SpA Tel: +39 (0) 344 58111 Fax: +39 (0) 344 56278 Client Warranty Prior to installation, the equipment referred to in this manual must be stored in a clean, dry environment, in accordance with the Company's published specification. Periodic checks must be made on the equipment's condition. In the event of a failure under warranty, the following documentation must be provided as substantiation: 1. A listing evidencing process operation and alarm logs at time of failure. 2. Copies of operating and maintenance records relating to the alleged faulty unit. Flow Metering Magnetic Flowmeters Electromagnetic, insertion type probes and watermeters. Turbine Flowmeters Wedge Flow Elements Mass Flow Meters Transmitters, sensors, controllers and batch/ display units. Level Control Submersible, Capacitance & Conductivity. Pneumatic Instrumentation Transmitters Indicating Controllers Recording Controllers

The Company's policy is one of continuous product improvement and the right is reserved to modify the information contained herein without notice. IM/CALMAS Issue 2 1997 ABB Printed in UK (3.97) ABB Kent-Taylor Ltd. St. Neots, Cambs. England, PE19 3EU Tel: (01480) 475321 Fax: (01480) 217948 ABB Kent-Taylor Ltd. Analytical & Flow Group Stonehouse, Glos. England, GL10 3TA Tel: (01453) 826661 Fax: (01453) 826358 ABB Instrumentation Inc. PO Box 20550, Rochester New York 14602-0550 USA Tel: (716) 292 6050 Fax: (716) 273 6207 ABB Kent-Taylor SpA 22016 Lenno Como Italy Tel: (0344) 58111 Fax: (0344) 56278